• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 190
  • 7
  • 7
  • 7
  • 7
  • 6
  • 6
  • 6
  • 6
  • 3
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 198
  • 135
  • 80
  • 63
  • 42
  • 38
  • 34
  • 33
  • 26
  • 24
  • 23
  • 23
  • 22
  • 21
  • 21
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Técnicas avançadas de controle aplicadas a sistemas de climatização visando conforto térmico / Roberto Zanetti Freire ; orientador, Gustavo Henrique da Costa Oliveira ; co-orientador, Nathan Mendes

Freire, Roberto Zanetti January 2006 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2006 / Inclui bibliografia / Este trabalho aborda o problema de análise e desenvolvimento de algoritmos para controle de sistemas de climatização que possuem apenas um atuador, como é o caso comumente encontrado em indústrias e residências. A base dos algoritmos é a estratégia de con
72

PAPEL DAS PROTEÍNAS SECRETADAS POR CÉLULAS RESIDENTES CARDÍACAS COMO POTENCIAIS INDUTORAS DA DIFERENCIAÇÃO CARDIOMIOGÊNICA DE CÉLULAS-TRONCO HUMANAS

REUS, THAMILE LUCIANE 01 September 2016 (has links)
Submitted by Luciane Willcox (luwillcox@gmail.com) on 2016-09-01T16:28:39Z No. of bitstreams: 1 Dissertacao - Thamile_versaofinal.pdf: 1994677 bytes, checksum: ae5ee13d8f71c37552b741b9a2c81a37 (MD5) / Approved for entry into archive by Luciane Willcox (luwillcox@gmail.com) on 2016-09-01T16:46:22Z (GMT) No. of bitstreams: 1 Dissertacao - Thamile_versaofinal.pdf: 1994677 bytes, checksum: ae5ee13d8f71c37552b741b9a2c81a37 (MD5) / Made available in DSpace on 2016-09-01T16:46:22Z (GMT). No. of bitstreams: 1 Dissertacao - Thamile_versaofinal.pdf: 1994677 bytes, checksum: ae5ee13d8f71c37552b741b9a2c81a37 (MD5) / As células-tronco mesenquimais (CTMs) são células indiferenciadas capazes de se autorrenovarem e diferenciarem em diversos tipos celulares; estas células têm sido amplamente avaliadas quanto ao uso em terapias para doenças cardiovasculares, visando recuperar o tecido cardíaco danificado. É sabido que o comportamento biológico das CTMs depende do microambiente onde se encontram, que é composto principalmente por células, matriz extracelular (MEC) e fatores solúveis. Desta forma, isolamos células residentes cardíacas através da cultura de explantes de aurícula e ventrículo cardíaco humano e realizamos a caracterização do fenótipo destas células, bem como de proteínas de MEC e do meio condicionado (fatores solúveis) secretados por elas. Constatamos que ambas as populações celulares são compostas por CTMs, fibroblastos cardíacos e possivelmente pericitos/miofibroblastos. Realizamos o cultivo destas células e isolamos a MEC por meio da descelularização das monocamadas celulares com uma solução de Triton X-100 0,5%. Por outro lado, obtivemos o meio condicionado (MC) de ambas as populações celulares e observamos que estes são compostos por diversas proteínas, muitas das quais sendo relacionadas aos processos de regulação da diferenciação celular, desenvolvimento e reparo tecidual. Devido ao fato destas populações celulares serem populações heterogêneas compostas de células encontradas no coração, procuramos avaliar o papel das proteínas de MEC e do MC secretados por elas em cultivos de CTMs. Primeiramente, observamos através de ensaios de viabilidade celular e morte por apoptose e necrose, que as MEC e os MCs não foram tóxicos para os cultivos de CTMs. Observamos que a MEC derivada de células de aurícula induziu redução da taxa de proliferação das CTMs em 24 horas. Em contrapartida, após 7 dias, o número de CTMs cultivadas na presença de ambos os MCs aumentou significativamente em relação ao controle, sugerindo um papel destas proteínas secretadas como indutoras da proliferação celular. Em relação a adesão, observamos que as MECs não influenciaram o número de CTMs aderidas em comparação com o controle de colágeno tipo I. Da mesma forma, não observamos diferença na taxa de migração e na marcação para GATA-4 e Troponina-I entre os grupos controle e os cultivados na presença das MECs e/ou MCs. Embora não tenhamos observado diferença nestes parâmetros, ao menos nas condições avaliadas neste estudo, conseguimos demonstrar através deste trabalho que as populações celulares derivadas de aurícula e ventrículo são secretoras ativas de diversas proteínas relacionadas a processos de desenvolvimento celular e possivelmente ao reparo do tecido cardíaco. Portanto, estas células podem representar uma importante fonte de fatores tróficos a ser avaliada como indutora de estímulos em células progenitoras com objetivos terapêuticos em lesões cardiovasculares.
73

Determinação dos coeficientes e avaliação das equações de desempenho de condicionadores de ar com vazão de refrigerante variável por Régis Altafini Machado

Machado, Regis Altafini January 2014 (has links)
Neste trabalho é feita uma simulação energética de um prédio de escritórios em Porto Alegre, utilizando um equipamento de ar condicionado de vazão de refrigerante variável (VRF) presente no exemplo do programa simulador (EnergyPlus). Com a carga térmica média (13.600 W) das cargas térmicas resultantes em cada zona térmica, se obteve um equipamento de ar condicionado comercial (unidade interna) com potência (14.000 W) que suprisse a carga térmica média. Através das tabelas do fabricante e do ajuste de curvas são encontradas as equações de desempenho do equipamento comercial e são traçados as curvas características. A seguir é feita uma nova simulação no prédio de escritórios, utilizando o equipamento comercial e comparando resultados com a simulação do equipamento de ar condicionado do exemplo como referência. São comparados os valores de consumo energético da edificação, cargas térmicas das serpentinas de expansão direta de resfriamento e de aquecimento e horas em que a temperatura da zona fica fora do ajuste do termostato no ano. A simulação demonstra que o equipamento VRF comercial (68.297,38 kWh) consome menos energia que o VRF do modelo do EnergyPlus (71.901,99 kWh). / In this dissertation is made an energy simulation of an office building in Porto Alegre, using a variable refrigerant flow air-conditioning (VRF) in this example model of the simulator program (EnergyPlus). With the average thermal load (13.600 W) of thermal loads resulting in each thermal zone, it got a commercial air conditioning unit (Internal unit) VRF with power (14.000 W) that provided the thermal loads of each zone. Through the tables of the manufacturer and the fitting curves are found performance equations of commercial device and their characteristics curves are plotted. The following is made a new office building simulation, using the commercial device and comparing the simulation results with the air conditioning of the example model as a reference. For the comparison are used the values of energy consumption building, the direct expansion cooling coil heat load, the direct expansion heating coil and the annual hours when the temperature zone was outside of set point the thermostat. The simulation shows that the VRF commercial equipment consumes less energy (68.297,38 kWh) than the VRF equipment of EnergyPlus model (71.901,99 kWh).
74

Análise de regressão do consumo de energia elétrica frente a variáveis arquitetônicas para edifícios comerciais climatizados em 14 capitais brasileiras /

Signor, Régis January 1999 (has links)
Dissertação (Mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. / Made available in DSpace on 2012-10-19T00:07:40Z (GMT). No. of bitstreams: 0Bitstream added on 2016-01-09T01:47:22Z : No. of bitstreams: 1 142020.pdf: 3482608 bytes, checksum: e2ddc50c54797e11d42cbfdf320f5499 (MD5)
75

Proposta de metodologia para aplicação de eficiência energética em uma usina hidrelétrica / Proposed methodology for implementation of energy efficiency in a hydroelectric power plant

Bimestre, Thiago Averaldo [UNESP] 21 January 2015 (has links) (PDF)
Made available in DSpace on 2015-04-09T12:28:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-01-21Bitstream added on 2015-04-09T12:47:35Z : No. of bitstreams: 1 000817181.pdf: 1845327 bytes, checksum: 6922795930213e43ac3c03e3989d1a0b (MD5) / Os projetos de eficiência energética desempenham um papel chave na melhoria da segurança energética, da sustentabilidade ambiental e do desempenho econômico. Este trabalho tem como objetivo apresentar o desenvolvimento e os resultados de um projeto piloto de eficientização energética aplicado a usina hidrelétrica de Paraibuna. Neste sentido, foi desenvolvida uma proposta de metodologia para otimização do uso da energia em toda a instalação de uma usina hidrelétrica, procurando, a partir de resultados de inspeção e de ensaios, analisar como a energia elétrica está sendo utilizada e propondo melhorias no que se refere à racionalização de sua aplicação. Além disso, a utilização de outras fontes de energia existentes e não aproveitadas, bem como a aplicação de novas tecnologias, são avaliadas, priorizando a redução de danos ao meio ambiente, a diminuição de custos de manutenção e o aumento de ganhos econômicos. As ações deste projeto foram dirigidas a programas de racionalização do uso de energia nos sistemas de iluminação, de ar condicionado, de bombeamento e nos trocadores de calor responsáveis pela refrigeração dos mancais das turbinas. As reduções obtidas foram significativas, chegando a 52% no sistema de iluminação, 28% no sistema de ar condicionado e 36% para os sistemas de bombeamento. Em relação a outras fontes de energia, apresenta-se um estudo sobre a implantação de sistemas fotovoltaicos conectados à rede que resultam em uma economia de 91,7 MWh/ano. Este trabalho também apresenta um estudo sobre o aproveitamento do potencial hidráulico disponível em uma ramificação do conduto forçado da usina com a implantação de uma mini turbina Pelton de 30 kVA. Finalmente, avalia-se a implantação de uma micro usina de biodiesel, suficiente para alimentar as barcas que realizam travessias na represa ... (Resumo Completo, clicar acesso eletrônico abaixo) / The energy efficiency projects play a key role in the improvement of energy security, environmental sustainability and economic performance. This research aims to present the development and results of a pilot project for energy efficiency applied to the hydroelectric power plant of Paraibuna. In this sense, a proposed methodology for optimization of energy use throughout the installation of a hydroelectric power plant was developed, looking, from inspection and testing results, analyze how electrical energy is being used and proposing improvements with regard to the rationalization of its application. In addition, the use of other existing energy sources and not exploited, as well as the application of new technologies, are evaluated, prioritizing the reduction of damage to the environment, reducing of maintenance costs and the increasing of economic gains. The actions of this project were aimed at rational energy use in lighting systems, air conditioning, pumping and heat exchangers responsible for the cooling of turbine bearings. Reductions achieved were significant, reaching 52% in the lighting system, 28% in the air conditioning system and 36% for pumping systems. About other energy sources, is presented a study on the implementation of photovoltaic systems connected to the network that result in a saving of 91.7 MWh/year. This work also presents a study on the use of the available hydraulic potential in a branch of the penstock of the plant with the implementation of a pelton turbine of 30 kVA. Finally, is evaluated the deployment of a small biodiesel plant, enough to feed the ferries which perform sailings on the dam. It is hoped that this study, expand research on energy efficiency by encouraging changes of habits, form features, updating and training the staff involved in the processes of production and use of energy and ... (Complete abstract click electronic access below)
76

Proposta de metodologia para aplicação de eficiência energética em uma usina hidrelétrica /

Bimestre, Thiago Averaldo. January 2015 (has links)
Orientador: Pedro Magalhães Sobrinho / Coorientador: Celso Eduardo Tuna / Banca: Eliana Vieira Canettieri / Banca: José Rui Camargo / Resumo: Os projetos de eficiência energética desempenham um papel chave na melhoria da segurança energética, da sustentabilidade ambiental e do desempenho econômico. Este trabalho tem como objetivo apresentar o desenvolvimento e os resultados de um projeto piloto de eficientização energética aplicado a usina hidrelétrica de Paraibuna. Neste sentido, foi desenvolvida uma proposta de metodologia para otimização do uso da energia em toda a instalação de uma usina hidrelétrica, procurando, a partir de resultados de inspeção e de ensaios, analisar como a energia elétrica está sendo utilizada e propondo melhorias no que se refere à racionalização de sua aplicação. Além disso, a utilização de outras fontes de energia existentes e não aproveitadas, bem como a aplicação de novas tecnologias, são avaliadas, priorizando a redução de danos ao meio ambiente, a diminuição de custos de manutenção e o aumento de ganhos econômicos. As ações deste projeto foram dirigidas a programas de racionalização do uso de energia nos sistemas de iluminação, de ar condicionado, de bombeamento e nos trocadores de calor responsáveis pela refrigeração dos mancais das turbinas. As reduções obtidas foram significativas, chegando a 52% no sistema de iluminação, 28% no sistema de ar condicionado e 36% para os sistemas de bombeamento. Em relação a outras fontes de energia, apresenta-se um estudo sobre a implantação de sistemas fotovoltaicos conectados à rede que resultam em uma economia de 91,7 MWh/ano. Este trabalho também apresenta um estudo sobre o aproveitamento do potencial hidráulico disponível em uma ramificação do conduto forçado da usina com a implantação de uma mini turbina Pelton de 30 kVA. Finalmente, avalia-se a implantação de uma micro usina de biodiesel, suficiente para alimentar as barcas que realizam travessias na represa ... (Resumo Completo, clicar acesso eletrônico abaixo) / Abstract: The energy efficiency projects play a key role in the improvement of energy security, environmental sustainability and economic performance. This research aims to present the development and results of a pilot project for energy efficiency applied to the hydroelectric power plant of Paraibuna. In this sense, a proposed methodology for optimization of energy use throughout the installation of a hydroelectric power plant was developed, looking, from inspection and testing results, analyze how electrical energy is being used and proposing improvements with regard to the rationalization of its application. In addition, the use of other existing energy sources and not exploited, as well as the application of new technologies, are evaluated, prioritizing the reduction of damage to the environment, reducing of maintenance costs and the increasing of economic gains. The actions of this project were aimed at rational energy use in lighting systems, air conditioning, pumping and heat exchangers responsible for the cooling of turbine bearings. Reductions achieved were significant, reaching 52% in the lighting system, 28% in the air conditioning system and 36% for pumping systems. About other energy sources, is presented a study on the implementation of photovoltaic systems connected to the network that result in a saving of 91.7 MWh/year. This work also presents a study on the use of the available hydraulic potential in a branch of the penstock of the plant with the implementation of a pelton turbine of 30 kVA. Finally, is evaluated the deployment of a small biodiesel plant, enough to feed the ferries which perform sailings on the dam. It is hoped that this study, expand research on energy efficiency by encouraging changes of habits, form features, updating and training the staff involved in the processes of production and use of energy and ... (Complete abstract click electronic access below) / Mestre
77

Redução da demanda de energia elétrica utilizando parâmetros construtivos visando ao conforto térmico

Baltar, Marta Garcia January 2006 (has links)
Made available in DSpace on 2013-08-07T18:53:34Z (GMT). No. of bitstreams: 8 000384715-Texto+Completo+Anexo+A-1.pdf: 135684 bytes, checksum: 3f1cd6455544828fcadc8473fb375222 (MD5) 000384715-Texto+Completo+Anexo+B-2.pdf: 247264 bytes, checksum: aa991c048fd94c1aff13330a27b15cd6 (MD5) 000384715-Texto+Completo+Anexo+C-3.pdf: 108774 bytes, checksum: 2fa6195b7e96e67534f6750e19f60b4a (MD5) 000384715-Texto+Completo+Anexo+D-4.pdf: 1178481 bytes, checksum: 4c30991cc03b044429a6c4cb833902ae (MD5) 000384715-Texto+Completo+Anexo+E-5.pdf: 489465 bytes, checksum: de2c0e0c0ef5ac46d8ab72a9a87fc304 (MD5) 000384715-Texto+Completo+Anexo+F-6.pdf: 74791 bytes, checksum: 928f6e04449fc87a4321d0a13142a268 (MD5) 000384715-Texto+Completo+Anexo+G-7.pdf: 275028 bytes, checksum: 1272aaa95cf373c971927dda9971a231 (MD5) 000384715-Texto+Completo-0.pdf: 1956020 bytes, checksum: 3db73ba49319745144db2d25f7331e16 (MD5) Previous issue date: 2006 / The purpose of this study is to evaluate the influence of building parameters on the electrical energy demand and consumption for air-conditioning. The building parameters evaluated were: glass types and exterior colors used to cover external and internal walls. The analysis was performed using EnergyPlus, thermo-energetic simulation program, and evaluated with a method developed to determine the efficiency of the building alternatives. The evaluation was performed based on the building of the Bruno Born Hospital, in Lajeado, Rio Grande do Sul. The main objective is to minimize the electrical energy consumption of the air-conditioning system and at the same time fulfill the comfort and sterilization requirements of the thirteen hospitalization rooms of the hospital, according to temperature indexes specified in NBR-6401. With the purpose of assessing the thermal environmental conditions and energy consumption, thermal comfort indexes, internal temperature and the necessary air-conditioning power for each of the hospitalization room were evaluated. The energy consumption of the used alternatives and the cost benefit ration were assessed. Through simulation, the results showed that with the use of thermal efficient materials, temperature exchanges between internal and external areas are minimized, lowering energy consumption of the air-conditioning system. / Este trabalho tem por objetivo avaliar a influência de parâmetros construtivos na demanda e consumo de energia elétrica para fins de condicionamento térmico ambiental. Os parâmetros construtivos avaliados englobam tipos de vidros, cores externas das fachadas e revestimento nas paredes internas. As análises são realizadas através do programa de simulação termoenergética EnergyPlus e avaliadas a partir de um método desenvolvido para analisar a eficácia das alternativas construtivas. As avaliações são realizadas tendo como base a edificação do Hospital Bruno Born, localizado em Lajeado, Rio Grande do Sul. A análise visa minimizar o consumo de energia elétrica no sistema de ar condicionado e atender todos os requisitos de conforto e assepsia de treze quartos de internação do estabelecimento hospitalar, de acordo com os índices de temperatura especificados na NBR-6401. Visando averiguar as condições do ambiente térmico e o consumo de energia elétrica, são avaliados os índices de conforto térmico, as temperaturas internas e a potência necessária do ar condicionado de expansão direta para cada um dos treze quartos de internação do hospital, verificando o consumo energético das alternativas utilizadas e a relação custo-benefício da melhor alternativa. Através das simulações constatou-se que com a utilização de materiais eficientes termicamente as trocas térmicas do interior com o exterior são minimizadas, diminuindo o consumo energético do sistema de ar condicionado.
78

Determinação dos coeficientes e avaliação das equações de desempenho de condicionadores de ar com vazão de refrigerante variável por Régis Altafini Machado

Machado, Regis Altafini January 2014 (has links)
Neste trabalho é feita uma simulação energética de um prédio de escritórios em Porto Alegre, utilizando um equipamento de ar condicionado de vazão de refrigerante variável (VRF) presente no exemplo do programa simulador (EnergyPlus). Com a carga térmica média (13.600 W) das cargas térmicas resultantes em cada zona térmica, se obteve um equipamento de ar condicionado comercial (unidade interna) com potência (14.000 W) que suprisse a carga térmica média. Através das tabelas do fabricante e do ajuste de curvas são encontradas as equações de desempenho do equipamento comercial e são traçados as curvas características. A seguir é feita uma nova simulação no prédio de escritórios, utilizando o equipamento comercial e comparando resultados com a simulação do equipamento de ar condicionado do exemplo como referência. São comparados os valores de consumo energético da edificação, cargas térmicas das serpentinas de expansão direta de resfriamento e de aquecimento e horas em que a temperatura da zona fica fora do ajuste do termostato no ano. A simulação demonstra que o equipamento VRF comercial (68.297,38 kWh) consome menos energia que o VRF do modelo do EnergyPlus (71.901,99 kWh). / In this dissertation is made an energy simulation of an office building in Porto Alegre, using a variable refrigerant flow air-conditioning (VRF) in this example model of the simulator program (EnergyPlus). With the average thermal load (13.600 W) of thermal loads resulting in each thermal zone, it got a commercial air conditioning unit (Internal unit) VRF with power (14.000 W) that provided the thermal loads of each zone. Through the tables of the manufacturer and the fitting curves are found performance equations of commercial device and their characteristics curves are plotted. The following is made a new office building simulation, using the commercial device and comparing the simulation results with the air conditioning of the example model as a reference. For the comparison are used the values of energy consumption building, the direct expansion cooling coil heat load, the direct expansion heating coil and the annual hours when the temperature zone was outside of set point the thermostat. The simulation shows that the VRF commercial equipment consumes less energy (68.297,38 kWh) than the VRF equipment of EnergyPlus model (71.901,99 kWh).
79

Sistema híbrido de climatização visando conforto térmico e eficiência energética

Flores, José Luis Olmos 06 September 2009 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Elétrica, 2009. / Submitted by Jaqueline Ferreira de Souza (jaquefs.braz@gmail.com) on 2011-06-06T14:00:22Z No. of bitstreams: 1 2009_JoseLuisOlmosFlores.pdf: 2865819 bytes, checksum: 72409e7cfbe728a40697a0b4486c338a (MD5) / Approved for entry into archive by Jaqueline Ferreira de Souza(jaquefs.braz@gmail.com) on 2011-06-06T14:06:49Z (GMT) No. of bitstreams: 1 2009_JoseLuisOlmosFlores.pdf: 2865819 bytes, checksum: 72409e7cfbe728a40697a0b4486c338a (MD5) / Made available in DSpace on 2011-06-06T14:06:49Z (GMT). No. of bitstreams: 1 2009_JoseLuisOlmosFlores.pdf: 2865819 bytes, checksum: 72409e7cfbe728a40697a0b4486c338a (MD5) / A motivação do presente trabalho foi a busca do uso racional de energia elétrica visando ganho de produtividade e redução de custos, através de um equipamento de climatização híbrido (convencional + evaporativo), focado na área de automação predial e industrial. O objetivo deste trabalho de pós-graduação foi desenvolver um sistema de climatização que forneça uma melhor condição de conforto térmico, tendo renovação de ar e principalmente com menor consumo de energia elétrica dentro das Normas Técnicas vigentes. Para atingir o objetivo desejado foram analisadas as instalações a climatizar, os sistemas de condicionamento de ar existentes e a forma de operação dos diversos equipamentos considerando o consumo de eletricidade. Os resultados alcançados foram melhor conforto térmico e, redução do consumo de energia elétrica através da utilização do sistema híbrido de climatização. _______________________________________________________________________________ ABSTRACT / The motivation of the present work is the search for rational use of electric power, improving productivity and costs reduction through a hybrid climatization equipment (conventional + evaporative), focused in building and industrial automation. The objective of dissertation is to develop a climatization system that gives thermal comfort with electric power consumption reduction, aiming to the Federal Technical Norms and the environmental concerns. To reach the desired the existing air conditioning system and the operation be analyzed, and new equipment have been designed, constructed and installed. The obtained results were: better thermal comfort, as well as cost reduction with electricity through with the use of hybrid system.
80

Modelagem de um sensor virtual para controle do conforto térmico

Santos, Rafael Lourenço dos 28 February 2011 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Elétrica, 2011. / Submitted by Jaqueline Ferreira de Souza (jaquefs.braz@gmail.com) on 2011-09-26T12:11:54Z No. of bitstreams: 1 2011_RafaelLourencodosSantos.pdf: 75067223 bytes, checksum: bf1357b479c60664ff6fe4bb278a32ad (MD5) / Approved for entry into archive by Jaqueline Ferreira de Souza(jaquefs.braz@gmail.com) on 2011-09-26T12:12:28Z (GMT) No. of bitstreams: 1 2011_RafaelLourencodosSantos.pdf: 75067223 bytes, checksum: bf1357b479c60664ff6fe4bb278a32ad (MD5) / Made available in DSpace on 2011-09-26T12:12:28Z (GMT). No. of bitstreams: 1 2011_RafaelLourencodosSantos.pdf: 75067223 bytes, checksum: bf1357b479c60664ff6fe4bb278a32ad (MD5) / O consumo de energia para condicionamento de ar responde por uma parte relevante do uso de energia elétrica no Brasil. Em relação a outros aparelhos eletrodomésticos, os aparelhos de ar-condicionado ainda estão presentes em um número pequeno de residências brasileiras. No entanto, em mantendo-se a melhora nas condições econômicas observadas nos últimos anos, haverá cada vez mais equipamentos instalados. Os efeitos gerados por picos de demanda relacionados ao efeito cumulativo de vários aparelhos de ar-condicionado ligados simultaneamente já foram responsáveis inclusive por alguns blecautes em várias redes de distribuição pelo mundo afora. O desenvolvimento de novos sistemas de controle para equipamentos de arcondicionado que possibilitem um controle mais apurado do conforto ambiental tornaria os equipamentos mais eficientes e com melhor desempenho. Neste trabalho é proposto um sensor virtual capaz de estimar o índice de conforto térmico em vários pontos de um ambiente hipotético. O sensor virtual é baseado numa solução numérica das equações médias de Navier-Stokes, incorporando o modelo de turbulência de duas equações, kepsilon. Todo o modelo físico foi implantado em uma linguagem Modelica, agregando equações para cálculo dos índices de conforto térmico em uma biblioteca que gera uma malha espacial e soluciona o modelo das equações médias de Navier-Stokes com equações de turbulência k-epsilon. Os resultados da simulação de um caso-base do sensor virtual foram confrontados com aqueles obtidos na solução de um problema equivalente modelado em uma ferramenta comercial para simulação de dinâmica dos fluidos. Os valores médios das variáveis termodinâmicas obtidos pelo modelo do sensor virtual mostraram-se aderentes quando comparados com sua contrapartida modelada em programa de simulação comercial, cujo código-fonte é privativo. O modelo permite acesso ao valor de todas as variáveis termodinâmicas e de conforto térmico em cada um dos elementos da malha de simulação. _______________________________________________________________________________ ABSTRACT / An important portion of electricity use in Brazil is due air-conditioning energy consumption. Unlike other home appliances, air-conditioning is still present in a small number of Brazilian houses. However, if Brazil succeeds improving its economic conditions as were observed in past years, a higher amount of Brazilian homes will have their own air-conditioning system. In addition, peak demand caused by a high number of air-conditioning apparatus connected simultaneously accounts for massive blackouts throughout the world. The development of control systems, designed specifically for airconditioners, allows a more accurate control of thermal comfort, resulting in more efficient and better performing systems. This work presents a virtual sensor model that can estimate a thermal comfort index at various points in a hypothetical environment. The virtual sensor is based on the numerical solution of Navier-Stokes averaged equations, complemented with k-epsilon turbulence model. The coding was carried out with Modelica modeling language, based on a library that generates a solution mesh and solves the Navier-Stokes averaged equations with k-epsilon turbulence model. The capability of calculating thermal comfort indexes in the mesh nodes was added to the library. Simulations were performed in order to validate the results obtained by the virtual sensor model against the results obtained by a similar problem modeled in a commercial program for fluid dynamics simulation. The simulation results obtained by the virtual sensor model were considered satisfactory, based on a comparison with its counterpart modeled and solved on the commercial simulation program. The model proposed can deliver thermodynamics and thermal comfort data whithin each element of the simulation mesh

Page generated in 0.0752 seconds