• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 477
  • 327
  • 44
  • 43
  • 20
  • 11
  • 7
  • 6
  • 5
  • 5
  • 4
  • 4
  • 3
  • 3
  • 3
  • Tagged with
  • 1117
  • 490
  • 448
  • 406
  • 327
  • 326
  • 292
  • 292
  • 87
  • 87
  • 75
  • 69
  • 67
  • 62
  • 62
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
311

Relação entre o movimento ortodôntico vestibular dos incisivos inferiores e características do osso alveolar vestibular e lingual: avaliação por meio da tomografia computadorizada cone-beam / Labial movement of the mandibular incisors and tomographic characteristics of the labial and lingual alveolar bone

Carolina Carmo de Menezes 14 November 2014 (has links)
Introdução: O objetivo principal desta pesquisa foi avaliar as características do osso alveolar vestibular e lingual, na região ântero-inferior, em pacientes que realizaram tratamento ortodôntico corretivo não cirúrgico da má oclusão de Classe II. Material e Métodos: A amostra foi constituída de 32 pacientes divididos de acordo com a inclinação vestibular dos incisivos inferiores em dois grupos: Grupo Experimental que protruíram ou inclinaram os incisivos para vestibular em 1,5 mm e/ou 10o ou mais e Grupo Controle que protruíram ou inclinaram os incisivos para vestibular menos de 1,5 mm e/ou 10o. Estes grupos foram compatibilizados de acordo com a idade, sexo e padrão facial. O nível da crista óssea alveolar vestibular e lingual, a espessura da tábua óssea vestibular e lingual na metade e no ápice radicular, assim como a presença ou ausência de deiscências e fenestrações foram avaliados nos cortes parassagitais em imagens de tomografia computadorizada cone-beam, realizadas após um ano da remoção do aparelho fixo, na região dos seis dentes anteriores inferiores. A comparação intergrupos foi realizada por meio do teste t e o teste de Mann-Whitney para as avaliações quantitativas e pelo teste Exato de Fisher para as avaliações qualitativas (p<0,05). Verificou-se a correlação entre as medidas quantitativas e a quantidade de protrusão/inclinação vestibular dos incisivos inferiores por meio dos testes de Pearson e de Spearman. Resultados: O grupo experimental demonstrou espessura da tábua óssea vestibular no nível apical maior para os incisivos centrais, e espessura da tábua óssea lingual no nível apical menor para os incisivos centrais, laterais e caninos, em relação ao grupo controle. Maior número de deiscências na lingual dos incisivos centrais e fenestrações na vestibular dos incisivos laterais foi encontrado para o grupo experimental em comparação ao grupo controle. No nível apical dos incisivos centrais e caninos, quanto maior a quantidade de inclinação vestibular e protrusão dos incisivos inferiores durante o tratamento, menor espessura da tábua óssea lingual e maior espessura da tábua óssea vestibular. Conclusões: O grau de protrusão dos incisivos inferiores apresentou influência sobre a espessura da tábua óssea ao nível do ápice radicular dos dentes anteriores. Somente deiscências linguais e fenestrações ósseas vestibulares foram observadas com mais frequência no grupo tratado com significante protrusão dos incisivos. / The aim of this study was to assess the morphology of the mandibular incisors labial and lingual alveolar bone in patients who underwent Class II nonsurgical orthodontic treatment. The sample comprised 32 patients who were divided into two groups according to the amount of labial protrusion of the mandibular incisors: the experimental group (EG) - which protruded or labially tipped the incisors 1.5 mm and/or 10o or more; and the control group (CG) - which protruded or labially tipped the incisors less than 1.5 mm and/or 10o. These groups were matched according to age, sex and facial pattern. Measurements of the vertical alveolar bone level and alveolar bone thickness of the labial and lingual plate, as well as the presence and absence of dehiscences and fenestrations were evaluated in cone-beam computed tomography cross-sectional images of the six mandibular anterior teeth, taken one year after appliance removal. Intergroup comparisons were performed using Mann-Whitney and t tests for quantitative assessments and Fisher Exact Test for qualitative assessments. Correlation between quantitative measures and the amount of protrusion/labial inclination of the mandibular incisors was evaluated with Pearson and Spearman tests. The experimental group showed significant greater thickness of the apical buccal bone plate of the central incisors and smaller thickness of the apical lingual bone plate of the central incisors, lateral incisors and canines. Greater number of lingual dehiscences in the central incisors and labial fenestrations in the lateral incisors was found for the experimental group. At the apical level of the central incisors and canines, the greater the amount of labial inclination and protrusion of the mandibular incisors during treatment, the smaller was the lingual bone plate thickness and greater was the thickness of the labial bone plate. The protrusion degree of the mandibular incisors influenced the apical bone plate thickness of the anterior teeth. Only lingual dehiscences and labial bone fenestrations were more frequently observed in the group treated with significant protrusion of the incisors.
312

Avaliação da prevalência de variações anatômicas do complexo ostiomeatal e de afecções inflamatórias dos seios maxilares por meio da tomografia computadorizada de feixe cônico

Nogueira, Alexandre Simões 25 April 2013 (has links)
Introdução. O estudo da anatomia da região naso-sinusal e de suas variações é de grande importância diagnóstica e para a definição de condutas de tratamento nas áreas da Odontologia e da otorrinolaringologia, principalmente em relação aos seios maxilares, regiões anatômicas diretamente relacionadas com os dentes superiores. Objetivos. Avaliar por meio da tomografia computadorizada de feixe cônico (TCFC) a prevalência das seguintes variações anatômicas do complexo ostiomeatal: concha bolhosa, células de Haller, desvios de septo nasal e aerações do processo uncinado e, ainda, avaliar a prevalência das afecções inflamatórias dos seios maxilares. A presença das variações anatômicas supramencionadas e de alterações apicais de dentes posteriores superiores serão correlacionadas com a presença das afecções inflamatórias dos seios maxilares. Material e Métodos. Foram avaliados 100 exames de TCFC de pacientes odontológicos escolhidos de forma aleatória de acordo com protocolos de aquisição que abrangiam as regiões anatômicas de interesse ao estudo. Todas as tomografias do estudo foram adquiridas através do tomógrafo i-Cat, modelo Classic e as imagens em formato DICOM foram visualizadas e analisadas através do software i-Cat Vision. Resultados. Os exames tomográficos avaliados eram de 100 pacientes, 43 do gênero masculino (média de idade de 23,7anos) e 57 do gênero feminino (média de idade de 25,8 anos). Todas as variações anatômicas em estudo foram visualizadas nos exames analisados. Oitenta e cinco indivíduos apresentaram uma ou mais de uma variação concomitantemente, enquanto 15 indivíduos não apresentaram qualquer tipo de variação anatômica. A maior prevalência foi de indivíduos que apresentaram duas variações anatômicas (38%). Desvio de septo nasal ocorreu em 67% dos pacientes. Considerando-se a possibilidade de ocorrência bilateral em cada paciente, concha média bolhosa, células de Haller e aeração do processo uncinado apresentaram, respectivamente, as seguintes prevalências: 31,5%; 20%; e 9%. As afecções inflamatórias dos seios maxilares apresentaram as seguintes distribuições e taxas de prevalências considerando-se análises bilaterais: em 74 seios maxilares não foram visualizadas afecções inflamatórias (37%); espessamento da mucosa sinusal foi visualizado em 97 seios maxilares (48,5%); e cistos de retenção / pseudocistos estavam presentes em 29 seios maxilares (14,5%). O grau de espessamento da mucosa dos seios maxilares foi estabelecido através de medidas milimétricas e, considerando-se análises bilaterais sem incluir cistos de retenção/pseudocistos, as seguintes distribuições e taxas de prevalência foram encontradas: classe I (mucosa sem alterações) foi vista em 74 seios maxilares (43,27%); espessamento tipo classe II (até 2mm) foi visualizado em 30 seios maxilares (17,54%); classe III (entre 2mm e 4mm) em 13 seios maxilares (7,60%); classe IV (entre 4mm e 10mm) em 30 seios maxilares (17,54%); e classe V (maior que 10mm) em 24 seios maxilares (14,03%). Na análise bilateral das condições dentárias / ósseas na região posterior da maxila encontrou-se que em 162 situações (81%) todos os dentes apresentavamse hígidos, enquanto em 11 situações (5,5%) havia a presença de hipodensidades ósseas compatíveis com lesões apicais. Aplicando-se o teste estatístico exato de Fisher (p<0,05) avaliou-se a correlação entre as hipodensidades ósseas apicais e a presença de afecções inflamatórias dos seios maxilares e os resultados mostraram que os achados foram casuais, sem significância estatística. Aplicando-se o mesmo teste estatístico para avaliar a correlação entre as variações anatômicas objetos da presente pesquisa e as afecções inflamatórias dos seios maxilares, os resultados foram estatisticamente significativos. Conclusão. A TCFC permitiu identificar todas as variações anatômicas do complexo ostiomeatal objetos do estudo e os diferentes tipos de afecções inflamatórias dos seios maxilares, assim como determinar as suas taxas de prevalência. As variações anatômicas apresentaram prevalência de 85% e o desvio de septo nasal foi a mais comum (67%). As afecções inflamatórias dos seios maxilares apresentaram taxa de prevalência de 65% e espessamento da mucosa sinusal foi a mais comum (47,5%). Enquanto as variações anatômicas do complexo ostiomeatal foram correlacionadas com as afecções inflamatórias dos seios maxilares, o mesmo não ocorreu em relação às hipodensidades apicais. / Introduction. The study of anatomy nasal-sinus and its variations is of great importance for the diagnosis and definition of behavior treatment in the areas of dentistry and otolaryngology, particularly in relation to the maxillary sinuses, anatomical regions directly related to the upper teeth. Objectives. Evaluate by beam computed tomography (CBCT) the prevalence of the following complex anatomical variations ostiomeatal: concha bullosa, Haller cells, nasal septum deviation and airings of the uncinate process, and also to assess the prevalence of inflammatory diseases of the sinuses jaws. The presence of anatomical variations above and apical changes of maxillary posterior teeth will be correlated with the presence of inflammatory diseases of the maxillary sinuses. Materials and Methods. We evaluated 100 CBCT examinations of dental patients chosen at random according to acquisition protocols covering the anatomical regions of interest to the study. All scans were acquired through the study of the tomograph i-Cat, Classic model and the images in DICOM format were viewed and analyzed using the software i-Cat Vision. Results. CT scans were evaluated for 100 patients, 43 males (mean age 23.7 years) and 57 females (mean age 25.8 years). All anatomical variations in the study were displayed in the images analyzed. Eightyfive subjects had one or more concomitant variation, while 15 subjects did not show any anatomical variation. The highest prevalence was individuals who had two anatomical variations (38%). Septal deviation occurred in 67% of patients. Considering the possibility of bilateral occurrence in each patient, concha bullosa, Haller cells and aeration of the uncinate process showed, respectively, the following rates: 31.5%, 20% and 9%. The inflammatory diseases of the maxillary sinuses showed the following distributions and prevalence rates considering bilateral analysis: in 74 maxillary sinuses were not visualized inflammatory disorders (37%), thickening of the Sinus mucosa was seen in 97 maxillary sinuses (48.5%) , retention cysts and / pseudocysts were present in the maxillary sinus 29 (14.5%). The degree of mucosal thickening of the maxillary sinuses was established through measures millimeter and considering bilateral analyzes excluding retention cysts / pseudocysts, the following distributions and prevalence rates were found: class I (unchanged mucosa) was seen in 74 maxillary sinuses (43.27%), thickened class II (up to 2mm) was seen in 30 maxillary sinuses (17.54%), Class III (2mm to 4mm) in 13 maxillary sinuses (7.60%); Class IV (between 4mm and 10mm) in 30 maxillary sinuses (17.54%) and Class V (greater than 10 mm) at 24 maxillary sinuses (14.03%). In the analysis of bilateral dental conditions / bone in the posterior maxilla was found that in 162 cases (81%) had all teeth are healthy, while in 11 cases (5.5%) had the presence of bone hipodensidades compatible apical lesions. Applying the Fisher exact test statistic (p <0.05) assessed the correlation between hipodensidades apical bone and the presence of inflammatory diseases of the maxillary sinuses and the results showed that the findings were casual, without statistical significance. Applying the same statistical test to evaluate the correlation between anatomical variations objects of this research and inflammatory diseases of the maxillary sinuses, the results were statistically significant. Conclusion. The CBCT identified all variations osteomeatal complex anatomical objects of study and the different types of inflammatory diseases of the maxillary sinuses, as well as determine their prevalence rates. Anatomical variations showed a prevalence of 85% and a deviated nasal septum was the most common (67%). The inflammatory diseases of the maxillary sinuses showed a prevalence rate of 65% and thickening of the sinus mucosa was the most common (47.5%). While the complex anatomical variations ostiomeatal were correlated with inflammatory diseases of the maxillary sinuses, this did not occur in relation to apical hipodensidades.
313

Relação entre o movimento ortodôntico vestibular dos incisivos inferiores e características do osso alveolar vestibular e lingual: avaliação por meio da tomografia computadorizada cone-beam / Labial movement of the mandibular incisors and tomographic characteristics of the labial and lingual alveolar bone

Menezes, Carolina Carmo de 14 November 2014 (has links)
Introdução: O objetivo principal desta pesquisa foi avaliar as características do osso alveolar vestibular e lingual, na região ântero-inferior, em pacientes que realizaram tratamento ortodôntico corretivo não cirúrgico da má oclusão de Classe II. Material e Métodos: A amostra foi constituída de 32 pacientes divididos de acordo com a inclinação vestibular dos incisivos inferiores em dois grupos: Grupo Experimental que protruíram ou inclinaram os incisivos para vestibular em 1,5 mm e/ou 10o ou mais e Grupo Controle que protruíram ou inclinaram os incisivos para vestibular menos de 1,5 mm e/ou 10o. Estes grupos foram compatibilizados de acordo com a idade, sexo e padrão facial. O nível da crista óssea alveolar vestibular e lingual, a espessura da tábua óssea vestibular e lingual na metade e no ápice radicular, assim como a presença ou ausência de deiscências e fenestrações foram avaliados nos cortes parassagitais em imagens de tomografia computadorizada cone-beam, realizadas após um ano da remoção do aparelho fixo, na região dos seis dentes anteriores inferiores. A comparação intergrupos foi realizada por meio do teste t e o teste de Mann-Whitney para as avaliações quantitativas e pelo teste Exato de Fisher para as avaliações qualitativas (p<0,05). Verificou-se a correlação entre as medidas quantitativas e a quantidade de protrusão/inclinação vestibular dos incisivos inferiores por meio dos testes de Pearson e de Spearman. Resultados: O grupo experimental demonstrou espessura da tábua óssea vestibular no nível apical maior para os incisivos centrais, e espessura da tábua óssea lingual no nível apical menor para os incisivos centrais, laterais e caninos, em relação ao grupo controle. Maior número de deiscências na lingual dos incisivos centrais e fenestrações na vestibular dos incisivos laterais foi encontrado para o grupo experimental em comparação ao grupo controle. No nível apical dos incisivos centrais e caninos, quanto maior a quantidade de inclinação vestibular e protrusão dos incisivos inferiores durante o tratamento, menor espessura da tábua óssea lingual e maior espessura da tábua óssea vestibular. Conclusões: O grau de protrusão dos incisivos inferiores apresentou influência sobre a espessura da tábua óssea ao nível do ápice radicular dos dentes anteriores. Somente deiscências linguais e fenestrações ósseas vestibulares foram observadas com mais frequência no grupo tratado com significante protrusão dos incisivos. / The aim of this study was to assess the morphology of the mandibular incisors labial and lingual alveolar bone in patients who underwent Class II nonsurgical orthodontic treatment. The sample comprised 32 patients who were divided into two groups according to the amount of labial protrusion of the mandibular incisors: the experimental group (EG) - which protruded or labially tipped the incisors 1.5 mm and/or 10o or more; and the control group (CG) - which protruded or labially tipped the incisors less than 1.5 mm and/or 10o. These groups were matched according to age, sex and facial pattern. Measurements of the vertical alveolar bone level and alveolar bone thickness of the labial and lingual plate, as well as the presence and absence of dehiscences and fenestrations were evaluated in cone-beam computed tomography cross-sectional images of the six mandibular anterior teeth, taken one year after appliance removal. Intergroup comparisons were performed using Mann-Whitney and t tests for quantitative assessments and Fisher Exact Test for qualitative assessments. Correlation between quantitative measures and the amount of protrusion/labial inclination of the mandibular incisors was evaluated with Pearson and Spearman tests. The experimental group showed significant greater thickness of the apical buccal bone plate of the central incisors and smaller thickness of the apical lingual bone plate of the central incisors, lateral incisors and canines. Greater number of lingual dehiscences in the central incisors and labial fenestrations in the lateral incisors was found for the experimental group. At the apical level of the central incisors and canines, the greater the amount of labial inclination and protrusion of the mandibular incisors during treatment, the smaller was the lingual bone plate thickness and greater was the thickness of the labial bone plate. The protrusion degree of the mandibular incisors influenced the apical bone plate thickness of the anterior teeth. Only lingual dehiscences and labial bone fenestrations were more frequently observed in the group treated with significant protrusion of the incisors.
314

Geometry of actions, expanders and warped cones

Vigolo, Federico January 2018 (has links)
In this thesis we introduce a notion of graphs approximating actions of finitely generated groups on metric and measure spaces. We systematically investigate expansion properties of said graphs and we prove that a sequence of graphs approximating a fixed action ρ forms a family of expanders if and only if ρ is expanding in measure. This enables us to rely on a number of known results to construct numerous new families of expander (and superexpander) graphs. Proceeding in our investigation, we show that the graphs approximating an action are uniformly quasi-isometric to the level sets of the associated warped cone. The existence of such a relation between approximating graphs and warped cones has twofold advantages: on the one hand it implies that warped cones arising from actions that are expanding in measure coarsely contain families of expanders, on the other hand it provides a geometric model for the approximating graphs allowing us to study the geometry of the expander thus obtained. The rest of the work is devoted to the study of the coarse geometry of warped cones (and approximating graphs). We do so in order to prove rigidity results which allow us to prove that our construction is flexible enough to produce a number of non coarsely equivalent new families of expanders. As a by-product, we also show that some of these expanders enjoy some rather peculiar geometric properties, e.g. we can construct expanders that are coarsely simply connected.
315

Prediction of Fire Growth on Furniture Using CFD

Pehrson, Richard 20 May 1999 (has links)
A fire growth calculation method has been developed that couples a computational fluid dynamics (CFD) model with bench scale cone calorimeter test data for predicting the rate of flame spread on compartment contents such as furniture. The commercial CFD code TASCflow has been applied to solve time averaged conservation equations using an algebraic multigrid solver with mass weighted skewed upstream differencing for advection. Closure models include k-epsilon for turbulence, eddy breakup for combustion following a single step irreversible reaction with Arrhenius rate constant, finite difference radiation transfer, and conjugate heat transfer. Radiation properties are determined from concentrations of soot, CO2 and H2O using the narrow band model of Grosshandler and exponential wide band curve fit model of Modak. The growth in pyrolyzing area is predicted by treating flame spread as a series of piloted ignitions based on coupled gas-fluid boundary conditions. The mass loss rate from a given surface element follows the bench scale test data for input to the combustion prediction. The fire growth model has been tested against foam-fabric mattresses and chairs burned in the furniture calorimeter. In general, agreement between model and experiment for peak heat release rate (HRR), time to peak HRR, and total energy lost is within pm 20%. Used as a proxy for the flame spread velocity, the slope of the HRR curve predicted by model agreed with experiment within pm 20% for all but one case.
316

Bench Scale Apparatus Measurement Uncertainty and Uncertainty Effects on Measurement of Fire Characteristics of Material Systems

Zhao, Lei 01 May 2005 (has links)
Traditional probability and statistics methodologies recommended by ISO and NIST were applied to standardize measurement uncertainty analysis on calorimetry bench scale apparatuses. The analysis was conducted for each component instrument (direct measurement) and each related physics quantity measured indirectly. There were many sources contributing to the ultimate uncertainty, however, initially, we dealt with the intrinsic uncertainty of each measuring instrument and the uncertainty from calibration. All other sources of uncertainty, i.e., drift, data acquisition, data reduction (round off, truncation, and curve smoothing) and personal operation were assumed to be negligible. Results were expressed as an interval having 95% confidence that the ¡°true¡± value would fall within. A Monte Carlo Simulation technique with sampling size of 10000 was conducted to model the experiments. It showed that at least 95% of the modeled experiment results were inside the estimate interval. The consistency validated our analysis method. An important characteristic of composite material systems is the ability to ¡°custom design¡± the system to meet performance criteria such as cost, durability, strength and / or reaction to fire. To determine whether a new system is an improvement over previous ones and can meet required performance criteria, sufficiently accurate and precise instruments are needed to measure the system¡¯s material properties in bench scale testing. Commonly used bench scale apparatuses are the cone calorimeter (Cone) and the FMGR fire propagation apparatus (FPA). For this thesis, thermally ¡°thin¡± and ¡°thick¡± specimens of a natural composite, red oak, were tested in the Cone in an air environment and in the FPA in a nitrogen environment. Cone test data of two FRP composite systems from the previous work of Alston are also considered. The material reaction to fire properties were estimated considering both ignition and pyrolysis measurements made via the Cone and FPA. Investigation of the ultimate uncertainty of these material fire properties based on the intrinsic uncertainty of the component instruments (e.g. load cell) as well as the uncertainty introduced via use of a current ignition and pyrolysis model are considered.
317

Planejamento do tamanho do implante dentário utilizando imagens de radiografia panorâmica digital e tomografia computadorizada de feixe cônico

Correa, Leticia Ruhland January 2012 (has links)
O objetivo deste estudo foi comparar o tamanho do implante dentário (largura e comprimento) planejado utilizando-se radiografias panorâmicas digitais (D-pan), reconstruções panorâmicas geradas a partir de Tomografia Computadorizada de Feixe Cônico (TCFC-pan), e imagens transversais de Tomografia Computadorizada de Feixe Cônico (TCFC-transversais), em quatro sistemas de implantes. Para tal, foram avaliados 103 sítios de implantes unitários nas regiões de pré-molares superiores e molares inferiores em 71 pacientes. Em cada paciente foram realizadas uma radiografia panorâmica digital (D-pan) e uma Tomografia Computadorizada de Feixe Cônico (TCFC). Para a realização da D-pan, foi colocada uma esfera de metal de 5 mm de diâmetro na região edêntula para que fosse realizada a calibração linear da imagem. Os dados adquiridos nas TCFC foram reconstruídos em imagens panorâmicas de 10 mm de espessura (TCFC-pan) e em imagens transversais de 1 mm de espessura (TCFC-transversais). Foram realizadas medidas em todas as imagens. Todas as modalidades de imagem foram exibidas no mesmo monitor e avaliadas por três observadores que utilizando o programa PorDios, identificaram quatro pontos de referência no espaço disponível e delimitaram o sítio de implante. Os tamanhos (largura e comprimento) dos implantes foram comparados entre as três modalidades de imagem e as diferenças foram analisadas. Utilizando o software SPSS, foi selecionado o tamanho do implante mais próximo (igual ou menor) que serviria no espaço disponível, baseado nos tamanhos existentes nos quatro sistemas utilizados (Nobel Biocare, Straumann, 3i e Neodent). O tamanho do implante selecionado nas imagens TCFC transversais foi comparado com o tamanho do implante selecionado nas outras duas modalidades (D-pan e TCFC-pan), para cada um dos sistemas separadamente. Como resultado, na maioria das vezes, o tamanho do implante foi menor nas TCFC-transversais, do que quando comparado com D-pan e TCFC-pan. Houve diferença significativa na largura do implante nas regiões de pré-molares entre D-pan e TCFC-pan. O implante foi significantemente mais curto na TCFC-transversal do que na D-pan, nas regiões de molares. A maioria das mudanças ocorreu para um tamanho mais fino e mais curto, que resultou em um tamanho de implante significantemente menor nas TCFC-transversais. Os resultados permitem concluir que quando o implante é planejado utilizandose imagens transversais de TCFC este é selecionado em um tamanho mais fino e mais curto do que quando idealizados em radiografias panorâmicas digitais. / The objective of this study was to compare the implant size (width and length) planned with digital panoramic radiographs, CBCT-generated panoramic views, or CBCT cross-sectional images, in four implant systems. Seventy-one patients with a total of 103 single-unit implants in the upper premolar and/or lower molar regions were examined with digital panoramic radiography (D-PAN) and cone beam computed tomography (CBCT). A 5-mm in diameter metal ball was placed in the edentulous area for the D-PAN. CBCT data sets were reformatted to a 10-mm thick CBCT panoramic view (CBCT-pan) and 1-mm cross-sections (CBCT-cross). Measurements were performed in the images using dedicated software. All images were displayed on a monitor and assessed by three observers who outlined a dental implant by placing four reference points in the site of the implant-to-be. Differences in width and length of the implant-to-be from the three modalities were analyzed. An automated program selected the implant size, which was the closest (smaller or equal) size implant that would fit the measured size, based on the sizes available in four worldwide-used implant systems (Nobel Biocare, Straumann, 3i and Neodent). The implant size selected in the CBCT-cross images was then compared to that selected in the other two modalities (D-PAN and CBCT-pan) for each of the implant systems separately. The implant-to-be (average measurements among observers) was narrower when measured in CBCT-cross compared with both D-PAN and CBCT-Pan. For premolar sites, width also differed significantly between D-PAN and CBCT-pan modalities. The implant-to-be was also significantly shorter when recorded in CBCT-cross than in D-PAN. In premolar sites there were no significant differences in implant length among the three image modalities. It mattered very little for the change in implant step sizes whether CBCT-cross was compared to D-PAN or CBCT-pan images. Our results show that the selected implant size differs when planned on panoramic or cross-section CBCT images. In most cases implant size measured in crosssection images was narrower and shorter than implant size measured in a panoramic image or CBCT-based panoramic view.
318

Reabsorções radiculares internas simuladas : desenvolvimento de nova metodologia com desmineralização ácida e análise volumétrica com diferentes protocolos de aquisição tomográfica / Development of a new in vitro methodology to simulate internal root resorption and influence of different tomographic protocols in the measurement volume

Silveira, Priscila Fernanda da January 2013 (has links)
Introdução: As reabsorções radiculares internas (RRI) são lesões de difícil prognóstico e o diagnóstico é baseado em exames clínicos e de imagem. Estudos que avaliam a acurácia dos exames por imagem para a detecção de RRI, utilizam simulações realizadas por brocas, criando cavidades com forma e limites definidos diferentes da realidade clínica. Além disso, sabe-se que tão importante quanto a detecção da lesão de RRI é a capacidade de visualização do envolvimento da estrutura dentinária adjacente. Assim, este trabalho objetivou desenvolver uma nova metodologia para simulação de RRI com base na desmineralização ácida e, após, testar a influência de diferentes protocolos de aquisição de imagens tomográficas na medição do volume dessas lesões. Materiais e métodos: Foi testada uma metodologia de simulação de RRI, com ação progressiva de ácido nítrico 5% e hipoclorito de sódio 8%, em onze dentes monorradiculares. As cavidades geradas foram avaliadas em Microscopia Eletrônica de Varredura (MEV) e as medidas de diâmetro e profundidade foram correlacionadas com os tempos de ação do ácido. Imagens de Tomografia Computadorizada de Feixe Cônico (TCFC) foram adquiridas de todos os dentes da amostra em dois aparelhos, de FOV amplo e restrito, com três protocolos de tamanho de voxel cada: I-Cat Next Generation (voxel 0,200; 0,250; 0,300 mm) e Kodak 9000 3D (voxel 0,076; 0,100; 0,200 mm). As simulações de RRI foram mensuradas com uma ferramenta de cálculo de volume do software Dolphin 3D. Os valores médios de volume das cavidades foram comparados com Análise de Variância (ANOVA) e Teste Tukey ( =0,05). A validação das mensurações de volume obtidas pelo software foi realizada por meio de moldagem das cavidades com silicona de adição. Resultados: As simulações de RRI reproduziram lesões de diferentes tamanhos e com profundidades de 0.22 mm a 1.59 mm. Em relação às medidas volumétricas, não houve diferença estatística significante (P<0,05) entre os volumes de RRI mensurados a partir dos dois menores tamanhos de voxel em cada aparelho de TCFC, mas ambos foram diferentes estatisticamente (P>0,05) do volume calculado com os maiores tamanhos de voxel. Ainda, as médias de volume a partir das impressões em silicona foram menores que as mensuradas pelo voxel 0,200 mm. Conclusão: A metodologia de simulação de RRI proposta gerou cavidades com limites irregulares e com razão de diâmetro:profundidade mais semelhante ao processo de RRI in vivo. Diferentes protocolos de TCFC influenciam nas medidas de volume de RRI simuladas, ressaltando a importância da padronização na aquisição das imagens para acompanhamento dessas lesões. / Introduction: The internal root resorption (IRR) injuries are difficult to predict and the diagnosis is based on clinical and radiographic examination. Studies that evaluated the accuracy of imaging tests for the detection of IRR using simulations produced by burs, created cavities with different forms and limits of clinical reality. Furthermore, it is known that as important as the IRR detection is the ability to preview the involvement of adjacent dentinal structure. Thus, this study aimed to develop a new methodology for IRR simulation-based with acid demineralization and after investigate the influence of different tomographic protocols in the measurement of the IRR lesions volume. Materials and methods: A methodology was desenvolved for simulation of IRR with progressive action of 5% nitric acid and 8% sodium hypochlorite in eleven teeth single-rooted. IRR cavities produced were evaluated by scanning electron microscopy (SEM), measured in diameter and depth and after correlated with the acid times. Cone Beam Computed Tomography (CBCT) images were acquired of all teeth in two tomography devices, with large and restrict field of view (FOV) using three voxel sizes protocols: I-Cat Next Generation (voxel 0.200, 0.250, 0.300 mm) and Kodak 9000 3D (voxel 0.076, 0.100, and 0.200 mm). IRR simulations were measured with a tool for calculating volume of the Dolphin 3D software. Volume means of the IRR cavities were compared using Analysis of Variance (ANOVA) and Tukey test ( = 0.05). A validation of the tomographic measurements was performed with addition silicone impression. Results: The simulations reproduced IRR lesions with different sizes and depths (0.22mm to 1.59mm). Regarding volumetric measurements, there was no statistically significant (P<0,05) difference between the IRR volumes measured from the two smaller voxel sizes in each CBCT device, but both were statistically different (P>0,05) from the calculated volume with larger voxel sizes. Still, the volume means from silicone impressions were lower than those measured at 0.200 mm voxel. Conclusion: The IRR simulation methodology generated cavities with irregular borders and diameter:depth ratio more similar to in vivo process of IRR. Different protocols of CBCT influences the volume measures of IRR simulated, emphasizing the importance of standardization in the acquisition of CBCT images for monitoring these lesions.
319

Avaliação da anatomia mandibular e suas variações por meio da tomografia computadorizada de feixe cônico em uma população brasileira / Evaluation of mandibular anatomy and its variations by cone beam computed tomography in a brazilian population

Cunha, Rodrigo Montezano da January 2016 (has links)
O conhecimento da localização, bem como da configuração das estruturas anatômicas presentes na mandíbula e suas respectivas variações são extremamente importantes para o planejamento de procedimentos cirúrgicos que envolvam este osso. O presente estudo teve como objetivo avaliar a anatomia mandibular e suas variações por meio da tomografia computadorizada de feixe cônico (TCFC) em uma população brasileira. Foram utilizados 1254 exames de TCFC realizados no equipamento I-Cat Next Generation, (Imaging Sciences International®) sob um protocolo com voxel de 0,2 mm, FOV amplo (16cm x 13cm) e tempo de escaneamento de 40 segundos. Três examinadores treinados e calibrados avaliaram os exames por meio do software I-Cat Vision (Imaging Sciences International®). Os dados que foram coletados em um formulário Access (Microsoft® Office) e analisados para prevalência, também foram correlacionados, isolando as variáveis gênero e situação dentária (dentado total, dentado parcial e desdentado total. Os resultados de prevalência foram: forame mentual localizado entre o 1º e 2º pré-molar inferior (91,38%), alça anterior (12,57%), canais acessórios (40%), canal mandibular bífido (CMB) (22%) e canal mandibular corticalizado (33,84%). O canal mandibular, em toda sua extensão, está localizado mais para vestibular nas mulheres, com diferença estatisticamente significante entre gêneros (P=0,002). Não foi encontrada diferença na distância V-L na região de fóvea submandibular entre os gêneros. Os CMBs não tem predileção por gênero (P=0,186), havendo diferença estatisticamente significante entre os tipos (P=0,001), sendo o Retromolar o mais frequente. O uso dos exames de TCFC permitiu identificar características anatômicas mandibulares importantes em uma população brasileira, sugerindo que essas devam ser investigadas antes de intervenções cirúrgicas. / The knowledge of the location, as well as the configuration of the anatomical structures and their respective variations are extremely important for the planning of surgical procedures involving this bone. The aim of this study was evaluate the mandibular anatomy and its variations through Cone Beam Computed Tomography (CBCT) in a Brazilian population. A total of 1254 CBCT scans were performed on the I-Cat Next Generation (Imaging Sciences International®) equipment under a protocol with 0.2 mm voxel, wide FOV (16cm x 13cm) and 40 seconds scanning time. Three trained and calibrated examiners evaluated the exams using I-Cat Vision software (Imaging Sciences International®). The data that were collected in Access form (Microsoft® Office) and analyzed for prevalence. In line, were correlated with gender. The prevalence results were: mental foramen located between the 1st and 2nd lower premolars (91.38%), anterior loop (12.57%), accessory canals (40%), bifid mandibular canal (BMC) (22%) and corticalized mandibular canal (33.84%). The mandibular canal, in all its extension, is located more for vestibular in the women, with statistically significant difference between genders (P = 0,002). There is no difference in V-L distance between genders in submandibular fovea area. The BMCs do not have a gender preference (P = 0.186). However, there is a statistically significant difference between the types (P = 0.001), and Retromolar is the most frequent. The use of CBCT scans allowed the identification of important mandibular anatomical features in a Brazilian population, suggesting that these should be investigated before surgical interventions.
320

Nova metodologia para interpretação de ensaios de dissipação do piezocone

Pereira, Francisco da Silva January 2017 (has links)
Os ensaios de piezocone são frequentemente utilizados em obras de elevada complexidade e risco geotécnico para a determinação do coeficiente de adensamento de solos argilosos saturados. Contudo, obter o tempo de dissipação de 50% do excesso de poropressão, parâmetro fundamental para estimativa do coeficiente de adensamento, pode demandar demasiado tempo, tornando o ensaio menos atrativo para projetos de engenharia. Ainda, obter a poropressão de equilíbrio pode ser complicada em alguns casos, dificultando a determinação do coeficiente de adensamento através do ensaio de dissipação. Com o motivo de incentivar o uso do ensaio de dissipação para essa finalidade, o presente trabalho tem como objetivo propor uma nova metodologia para a determinação do tempo para dissipação de 50% do excesso de poropressão causado pela cravação do piezocone, fornecendo uma alternativa para a metodologia empregada atualmente, que seja independente da poropressão de equilíbrio e que necessite de menos tempo de ensaio. Para o desenvolvimento da metodologia foi realizada uma campanha de investigação geotécnica no campo experimental de Tubarão-SC. A campanha contou com 10 ensaios de dissipação atingindo valores superiores ou próximos a 70% de dissipação do excesso de poropressão, buscando equalização mais completa da curva de dissipação, a fim de comparar os resultados obtidos através da nova metodologia com os valores obtidos por métodos consagrados na prática de engenharia. Nessa dissertação foram utilizados dois equipamentos, um minipiezocone (MCPTu) de seção de área transversal de 5cm² com medidas de poropressão nas posições u1 e u2 e um piezocone convencional, com seção de área transversal de 10cm² e leitura de poropressão somente na posição u2. Para a validação da metodologia, buscou-se na literatura e junto à Geoforma Engenharia Ltda. (parceira da pesquisa) ensaios de dissipação que tenham atingido elevados graus de dissipação. Valores de coeficiente de adensamento horizontal obtidos pela solução consagrada de Houlsby e Teh (1991) e pela metodologia proposta nesse trabalho foram comparadas e a proposta de metodologia apresentada. / Piezocone tests are frequently employed in high complexity and geotechnical risk construction sites to obtain the coefficient of consolidation of saturated clayey soils. However, the time for 50% dissipation of the excess pore pressure, parameter required for the estimation of the coefficient of consolidation takes too long, rendering the piezocone dissipation test less attractive for engineering projects. Furthermore, in some cases it can be complicated to estimate the equilibrium pore pressure, making difficult to estimate the coefficient of consolidation from the dissipation test. With the goal of encouraging the use of dissipation test for this propose, the present dissertation propose a new methodology for the determination of the time required for 50% dissipation of the excess pore pressure, providing an alternative which is independent of the equilibrium pore pressure and that demands less time in the field. For the development of the methodology proposed by this work, a site investigation campaign was carried out at the Tubarão-SC (Brazil) experimental field. Dissipation tests were performed to degrees of dissipation higher or approximately of 70%, for a more complete equalization of the complete dissipation curve, with the aim of comparing results obtained by the methodology developed in this dissertation and the value obtained from well-established methods. Two equipaments were employed on this dissertation: a mini-piezocone (MCPTu), with a cross area of 5cm² with pore pressure measurement at two locations, u1 and u2 and a standard piezocone, with a cross area of 10cm² and pore pressure measurement at the u2 position. Furthermore, aiming the validation of the proposal methodology, data from dissipation tests available in the literature and provided by Geoforma Engenharia Ltda. (partner on this research) were also used. The coefficient of consolidation was estimated by the well-establish approach and by the methodology proposed on this dissertation, the values were confronted, and recommendations presented.

Page generated in 0.0825 seconds