• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 477
  • 326
  • 44
  • 43
  • 20
  • 11
  • 7
  • 6
  • 5
  • 5
  • 4
  • 4
  • 3
  • 3
  • 3
  • Tagged with
  • 1116
  • 489
  • 447
  • 405
  • 327
  • 326
  • 292
  • 292
  • 87
  • 87
  • 75
  • 69
  • 67
  • 62
  • 62
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
301

\"Estudo comparativo entre a tomografia computadorizada e a tomografia volumétrica na confecção de modelos de prototipagem\" / Comparison of cone beam computerized tomography and multislice computerized tomography for building rapid prototyping models

Saddy, Mario Sergio 07 December 2006 (has links)
O objetivo neste estudo foi comparar modelos de prototipagem, originados a partir de dados obtidos em exames de tomografia volumétrica (TV) e tomografia computadorizada (TC), a fim de verificar a precisão de reprodutibilidade destas tecnologias. Uma mandíbula seca foi submetida aos exames de TV (NewTom 9000? QR, Itália) e TC (Select SP-Elscint, Israel). Os dados obtidos nos exames foram manipulados em dois sistemas de tratamento de imagem, o 3D- Analyze (Mayo Clinic, E.U.A.) e o InVesalius (CenPRA, Brasil) e confeccionados protótipos, em duas diferentes tecnologias (SLS - sinterização seletiva a laser e 3DP - impressão tridimensional). A mandíbula seca (padrão ouro) e os oito conjuntos de protótipos gerados, sendo I-TC-Analyze?3DP; II-TC-Invesalius?3DP; III-TC-Analyze?SLS; IVTC- Invesalius-SLS; V-TV-Analyze?3DP; VI-TV-Invesalius?3DP; VIII-TV-Analyze? SLS; VIII-TV-Invesalius-SLS, foram submetidos a processos de engenharia reversa com a finalidade de digitalizar as superfícies dos objetos para uma comparação de cada modelo de prototipagem produzido com o padrão ouro, com precisão de 0,001mm. Os desvios de até 1mm e até 2mm foram calculados, comparados e analisados estatisticamente os erros percentuais. Os modelos de prototipagem rápida originados por meio da obtenção de dados de exames de tomografia computadorizada são mais precisos que os modelos de prototipagem originados por meio de dados de exames de tomografia volumétrica. / The purpose of this study is to compare rapid prototyping models created from cone beam computerized tomography (CBCT) and multislice computerized tomography (CT) data, in order to verify the accuracy of these technologies. A dry skull mandible was submitted in a CBCT (NewTom ? QR, Italy) and CT (Select SP-Elscint, Israel) exams. The tomographies data were processed by two different Medical Image processing systems, 3D-Analyze (Mayo Clinic, U.S.A.) and InVesalius (CenPRA, Brazil). Rapid prototypes models were built in two different rapid prototyping technologies, 3D Printer (3DP) and Selective Laser Sintering (SLS). The dry skull mandible (gold standard) and the eight prototypes, as follows; I-CT-Analyze?3DP; IICT- Invesalius?3DP; III-CT-Analyze?SLS; IV-CT-Invesalius-SLS; V-CBCT-Analyze? 3DP; VI-CBCT-Invesalius?3DP; VIII-CBCT-Analyze?SLS; VIII-CBCT-Invesalius-SLS, were submitted to a reverse engineering process aimed to digitalize the surfaces of the objects to compare each rapid prototype model with the gold standard with a precision of 0.001mm. Percentage deviations errors until 1.0mm and 2.0mm were calculated, compared and statistically analyzed. The prototyped models obtained with multislice computerized tomography data shows more accuracy than those obtained with data from cone beam computerized tomography.
302

Acurácia de medidas lineares em região posterior de mandíbulas obtidas por tomografia computadorizada de feixe cônico através de diferentes protocolos de aquisição / Accuracy of linear measurements in posterior region of mandible obtained by cone beam computed tomography through different acquisition protocols

Gama, Renata de Saldanha da 05 August 2013 (has links)
A utilização da tomografia computadorizada de feixe cônico (TCFC) permite avaliar a altura e espessura do osso remanescente para a instalação de implantes. As mandíbulas atrésicas necessitam de maior grau de detalhamento para obtenção de medidas. A autora, no presente estudo, avaliou a influência do tamanho dos voxels (0,125mm e 0,25mm) nas medidas de altura e espessura em 10 mandíbulas desdentadas e atrésicas. Para determinação dos cortes tomográficos no estudo foram utilizados fios metáticos nas regiões posteriores. Após o exame as mandíbulas foram seccionadas e as medidas diretas de altura e espessura foram obtidas pelo uso de paquímetro digital. Os resultados pelo teste ICC demonstraram não haver diferenças estatisticamente significantes entre as medidas realizadas pelos dois examinadores com paquímetro e as tomografias. Concluiu-se que a TCFC é confiável para realização de medidas na mandíbula e que o tamanho do voxel não interferiu no planejamento cirúrgico. / The use of cone beam computed tomography (CBCT) allows to evaluate the height and thickness of the remaining bone for implant placement. The atresic mandible requires higher level of detail for obtaining measurements. The author in the present study evaluates the influence of the voxel size (0.125 mm and 0.25 mm) in thickness and height measurements using 10 edentulous dry mandibles. For determination of the tomographic study were used metallic wires in the posterior regions. After examining, the mandibles were sectioned and direct measures of height and thickness were obtained through digital caliper. The results by ICC test showed no statistically significant differences between the measurements with caliper and tomograms made by two examiners. It was concluded that CBCT is trusted to carry out measurements in mandible and the voxel size did not affect the surgical planning.
303

Análise tridimensional das vias aéreas superiores de pacientes com fissura labiopalatina e discrepância maxilomandibular / Three-dimensional analysis of the upper airways of patients with cleft palate and maxillomandibular discrepancy

Lima, Thiago Freire 02 March 2015 (has links)
Objetivos: As fissuras labiopalatinas constituem a malformação congênita de maior prevalência na espécie humana. O fechamento cirúrgico do lábio e do palato, que visa restaurar a forma e a função, paradoxalmente impacta negativamente sobre o crescimento maxilar e, consequentemente, sobre a morfofisiologia nasal, levando à deformidades como desvio de septo e hipertrofia das conchas nasais. Estas alterações reduzem as dimensões internas da cavidade nasal e aumentam a resistência ao fluxo aéreo respiratório. Assim, foi objetivo do presente estudo avaliar tridimensionalmente o espaço aéreo faríngeo dos pacientes com fissura labiopalatina unilateral completa por meio de tomografia computadorizada de feixe cônico. Material e Métodos: Foram avaliados exames tomográficos de dois grupos de pacientes: 1) Grupo Controle (GC): 30 tomografias de pacientes sem FLP + discrepância maxilomandibular do tipo classe III de Angle, e, 2) Grupo Fissura (GF): 30 tomografias de pacientes com FLP unilateral completa + discrepância maxilomandibular do tipo classe III de Angle. Dois avaliadores treinados e calibrados avaliaram, em dois tempos distintos, as imagens por meio do software Dolphin Imaging 11.0, no qual foram obtidos valores de volume (V) faríngeo e da área seccional mínima faríngea (ASM). Os valores médios da ASM e do V, obtidos nas duas medições do avaliador 1, foram considerados para análise. A reprodutibilidade intra e interexaminador foram calculadas pelo oeficiente de Correlação Intraclasse. A significância das diferenças entre os grupos foram avaliadas pelo teste t de Student para amostras independentes. A correlação entre as variáveis foi aferida pelo Coeficiente de correlação de Pearson. Valores de p<0.05 foram considerados significantes. Resultados: Os valores médios de V (mm3) do GF (20,9±5,0) foram significantemente menores que os do GC (26,9±9,6) (p=0,004). Apesar de estatisticamente não significante, os indivíduos do GF apresentam as ASMs dimensionalmente menores (158,6±99,1) que as do GC (188,8±110,2). Constatou-se forte correlação positiva entre as variáveis ASM e V, nos grupos GC e GF (p<0.001) e forte correlação negativa entre as variáveis ASM e idade, apenas no grupo GF (p=0.017). Conclusão: A faringe do paciente com fissura labiopalatina unilateral completa com discrepância dento-esquelética classe III de Angle é volumetricamente menor que a de indivíduos sem fissura labiopalatina com o mesmo tipo de discrepância dento-esquelética. Este resultado sugere maior chance de colapsabilidade da faringe, e, consequentemente, maior risco para apneia obstrutiva do sono nesta população. / Objective: Cleft lip and palate (CLP) is the most prevalent congenital malformation in humans. Primary plastic surgeries, which main objective is to repair the anatomy and the function of the lip and palate, paradoxically, impair maxillary growth and, consequently, impact negatively on the nasal morphophysiology, leading to deformities such as septal deviation and turbinate hypertrophy. These changes reduce the internal nasal dimensions and increase the resistance to respiratory airflow. The aim of the present study was to evaluate three-dimensionally the pharyngeal airway space of individuals with complete unilateral cleft lip and palate by means of cone beam computed tomography. Materials and Methods: Two groups were evaluated: 1) Control group (CoG): 30 CT scans of individuals without CLP + Angle class III malocclusion, and 2) Cleft group (ClG): 30 CT scans of individuals with CLP + Angle class III malocclusion. Two trained and calibrated examiners assessed the images, in two different moments, by means of Dolphin Imaging 11.0 software. Mean values of pharyngeal volumes (V) and minimal cross-sectional areas (CSA) obtained by examiner 1 were considered for analysis. Intra and inter-examiner reproducibility were assessed by Intraclass correlation coeficiente test. The significance of differences between groups was evaluated by Student \"t\" test for independent samples. The correlation between variables was assessed using Pearson\'s correlation coefficient. P values <0.05 were considered significant. Results: Mean values of V (mm3) for the ClG (20,9±5,0) were significantly lower than for the CoG (26,9±9,6) (p=0,004). Although not statistically significant, individuals from the ClG presented with lower ASMs (158,6±99,1) than the CG individuals (188.8±110,2). A strong positive correlation was observed between the ASM and V variables in both groups (p <0.001) and a strong negative correlation was observed between the variables ASM and age, only for the ClG (p = 0.017). Conclusion: The pharynx of the patients with complete unilateral cleft lip and palate and with Angle Class III malocclusion is volumetrically smaller than that of individuals without cleft lip and palate and with the same type of skeletal discrepancy. This result suggests a greater chance for pharyngeal collapsibility in individuals with cleft lip and palate and, consequently, a greater risk for obstructive sleep apnea in this population.
304

Efeito do jateamento de óxido de alumínio e uso de selante industrial, na superfície de pilares protéticos Cone Morse, de restaurações implanto suportadas sobre a resistência ao contratorque / Effect of aluminum oxide blasting and use of industrial sealant on the outer abutment surface of the prosthetic morse taper system connection on the untightening torque

Tunes, Fábio Sanches Magalhães 18 June 2012 (has links)
Problemas com desenho de conexões protéticas sobre implantes, microfendas, afrouxamento e, consequentemente, perdas das estruturas protéticas reabilitadoras são tópicos frequentes do estudo odontológico. Conexões do tipo Cone Morse, devido às suas características, diminuíram o índice desses problemas, abrindo uma nova perspectiva para o sucesso da prótese sobre implante. Contudo, ainda é frequente encontrar componentes que falham no desempenho, levando à falência da restauração, especialmente quando esses componentes não são bem ajustados, bem fixados ou, ainda, não possuem, na sua geometria, características suficientes para suportar as forças laterais e oclusais de um ciclo mastigatório. O objetivo deste estudo é avaliar a influência do jateamento com óxido de alumínio sobre a superfície externa dos componentes protéticos, separadamente e em conjunto, com um adesivo industrial, em uma tentativa de aumentar os valores de torque de abertura de componentes apertados em seu torque recomendado, pelo fabricante ou menor. Neste ensaio, foram utilizados 36 implantes da marca Straumann®, de 10mm de comprimento com diâmetro de 4,8 mm, os quais foram divididos em 6 grupos: Grupo 1 = controle, torque de 35 N.cm; Grupo 2 = superfície jateada com óxido de alumínio (# 320) e torque de 35 N.cm; Grupo 3 = superfície jateada com óxido de alumínio (# 320) e torque de 25 N.cm; Grupo 4 = superfície jateada com óxido de alumínio (# 100) e torque de 25 N.cm; Grupo 5 = superfície jateada com óxido de alumínio (# 320), aplicação de adesivo e torque de 25 N.cm; Grupo 6 = superfície jateada com óxido de alumínio (# 100), aplicação de adesivo e torque de 25 N.cm, que receberam componentes protéticos sólidos de 5,5 mm de altura, regulares e alterados. As modificações incluídas foram o jateamento com partículas de óxido de alumínio (100 e 320 micra) e o uso de Loctite® 277 como adesivo industrial. Os conjuntos implante-componente foram levados até uma máquina de controle de tração, Instron®, e, após a sua calibração, as amostras dos grupos foram apertadas em 35 e 25 N.cm, com um conjunto catraca-torquímetro, com checagem visual e registro no software acoplado à máquina de ensaio. Após trinta dias, os grupos foram levados à máquina novamente e o conjunto abutment-implante foi desapertado, agora somente com registro no software da máquina de ensaio. Os valores e porcentagens da diferença entre torque de aperto e desaperto foram avaliados estatisticamente, e comparados entre os grupos. Para todas as associações, o valor de p deveria ser menor ou igual 0,05, para relevância. O grupo Jateado 35 N.cm, 320 micra, não apresentou valores mais altos do que o grupo Controle no momento do torque de desaperto, assim como os grupos Jateados 25 N.cm 100 e 320 micra. Os grupos Jateados 25 N.cm, 100 e 320 micra, com adesivo, mostraram uma resistência por volta de uma vez e meia maior, no torque de desaperto do que o grupo Controle 35 N.cm. / Problems with design of prosthetic implant connections, microleakage,! loosening which leads to loss of rehabilitative prosthetic structures are frequent topics of dental study. Morse taper connections, due to its characteristics, decreased the rate of these problems opening a new perspective to the success of the prosthesis supported over implant. However, it is still frequent to find components that fail in performance leading to failure of restoration especially when these components are not well adjusted, tightened or do not have in its geometry enough characteristics to support the occlusal and lateral forces in a masticatory cycle. The aim of this study is to evaluate the influence of blasting with aluminum oxide on the outer surface of the prosthetic components separately and in conjunction with an industrial adhesive in an attempt to increase the opening torque values of components tightened on their recommended torque by the manufacturer or less, therefore allowing the dentist an early intervention in the prosthetic rehabilitation. In this test, 36 Straumann® implants of 10mm high and 4,8mm wide were used. They were divided into six groups: Group 1 Solid abutments control group - 35 N.cm tightened; Group 2 - Solid sandblasted abutments, 35 N.cm aluminum oxide 320 microns size particles; Group 3 - Solid sandblasted abutments, 25 N.cm aluminum oxide 320 microns size particles; Group 4 - Solid sandblasted abutments, 25 N.cm aluminum oxide 100 microns size particles; Group 5 - Solid sandblasted abutments, 25 N.cm aluminum oxide 320 microns size particles with glue application; Group 6 - Solid sandblasted abutments, 25 N.cm aluminum oxide 100 microns size particles with glue application, which received 5,5 mm high regular and modified solid abutments. The included modifications were sandblasting with aluminum oxide particles (100 and 320 microns) and the use of Loctite® 277 as an industrial adhesive. The samples were taken to a traction control test machine, Instron ®, and after calibration the group samples were tightened on 35 and 25 N.cm with a ratchet-wrench set with visual check. The data was recorded in a software coupled to the test machine. After thirty days the groups were brought again to the test machine and the samples were untightened. At this point the resulting data was recorded only in the testing machine software. The values and percentages of the changes between the tightening and loosening torques were recorded and compared among the study groups. For all associations a p-value < 0.05 was considered significant. The group blasted 35 N.cm, 320 microns did not show higher values than the control group at the time of loosening torque as well as groups blasted 25 N.cm 100 and 320 microns. The groups blasted 25 N.cm, 100 and 320 microns with adhesive showed a resistance around one and a half times greater in the loosening torque than the control group 35 N.cm.
305

Interferência dos artefatos de imagem causados por acessórios ortodônticos metálicos em sobreposições de imagens de TCFC / Influence of streaking artifacts due to metallic orthodontic accessories in CBCT 3D model superimposition

Silva, Fernando Penteado Lopes da 06 July 2012 (has links)
O objetivo deste estudo foi avaliar, de forma quantitativa e qualitativa, se artefatos de imagem causados por acessórios ortodônticos metálicos interferem em sobreposições tridimensionais (3D) de imagens de Tomografia Computadorizada de Feixe Cônico (TCFC). Dez crânios secos humanos foram submetidos a três aquisições tomográficas: sem acessórios ortodônticos (T1), com braquetes e tubos ortodônticos de aço inoxidável colados às superfícies vestibulares dos dentes superiores e inferiores (T2), e com fios ortodônticos de aço inoxidável inseridos nas canaletas dos referidos acessórios (T3). Os arquivos DICOM originais foram convertidos em arquivos de imagem Analyze, por meio do software Medsquare. O passo seguinte constituiu-se no registro rígido entre os pares de imagens T2-T1 e T3-T1, por meio do software Bioimage. Após o registro, foram então realizadas as sobreposições 3D entre os referidos pares de imagens, utilizando-se o software MeshValmet. Este software realiza uma codificação por mapas de cores, a partir das distâncias obtidas durante o processo de sobreposição. Distâncias positivas são codificadas com tonalidades de vermelho, enquanto que as negativas recebem tonalidades de azul. A ausência de deslocamento entre estruturas sobrepostas recebem o valor 0,0mmm sendo codificadas com a cor verde. As imagens referentes a T2 e T3 foram sobrepostas em relação à T1 no mesmo plano de espaço, para cada crânio da amostra. A partir das referidas sobreposições, foram calculadas as seguintes medidas: Distâncias Máxima, Mínima e Média, Distância Mean Square (MSD), Distância Root Mean Square (RMS) e Mediana. Estas quatro últimas caracterizaram-se como medidas de tendência central, e representaram a faixa de valores de maior concentração de dados. Os acessórios metálicos causaram artefatos de imagem principalmente nas imagens T2 e T3, porém os mesmos não comprometeram o processo de sobreposição das mesmas em relação à T1. As Distâncias Máximas foram comparadas à medida Diagonal (D), calculada a partir das dimensões dos acessórios ortodônticos e representativa dos mesmos (D=7,5mm). Nesta comparação, o teste t de Student não mostrou diferença significativa (p 0,05) indicando, de forma numérica, que os artefatos não se mostraram estatisticamente importantes em relação às dimensões dos corpos metálicos que os causaram. As medidas de tendência central foram então comparadas ao valor 0,0mm, o qual representa ausência total de deslocamento entre as imagens sobrepostas. Neste caso, o teste t também não evidenciou diferença significativa (p 0,05), indicando que a maior concentração de distâncias entre pontos em T2-T1 e T3-T1 localizou-se próxima ao referido valor. Somado a isso, a avaliação qualitativa propiciada pelas imagens corroborou tal constatação. Na comparação entre as medidas em T2-T1 e T3-T1, os coeficientes de Pearson mostraram alta correlação em relação às medidas de tendência central, como Distância Média (r=0.86), MSD (r=0.87), RMS (r=0.97) e Mediana (r=0.74). Mediante a avaliação quantitativa, complementada pela interpretação qualitativa dos dados, concluiu-se que os artefatos de imagem não comprometeram o procedimento de sobreposição de modelos 3D no presente estudo. / The aim of this study was to determine whether the artifacts caused by orthodontic metallic accessories interfere with the accuracy of three-dimensional (3D) Cone Beam Computed Tomography (CBCT) model superimposition. Ten dry human skulls were subjected to 3 CBCT scans: without orthodontic brackets (T1), with stainless steel brackets bonded (T2) and with orthodontic arch wires inserted into the bracket slots (T3). Individual 3D surface models were generated for the T1, T2 and T3 images, and the within-surface distances between T2-T1 and T3-T1 were computed. Superimposition error was calculated assuming CBCT image registration of T2 and T3 with respect to T1 using plain superimposition. The following measures were evaluated: Maximum, Mean and Mean Square Distance (MSD), Root MSD (RMS) and Median. The metallic accessories caused image artifacts primarily in T2 and T3 images which, however, did not compromise the 3D model superimposition. The maximum distances of artifacts image points were compared to the representative measure of orthodontic accessories (7.5mm), and Student t test showed no significant differences (p0.05) between both measures. When measures of T2-T1 and T3-T1 were compared, the Pearson coefficients showed a high correlation regarding the central tendency measures, as follows: Mean Distance (r=0.86), MSD (r=0.87), RMS (0.97) and Median (r=0.74). The statistical findings, which were complemented by qualitative image data obtained from this study, depicted that streaking artifacts did not affect the accuracy of CBCT 3D model superimposition of dry human skulls.
306

Foraminas acessórias mandibulares em tomografia computadorizada de feixe cônico / Accessory mandibular foramina in cone-beam computed tomography

Ikuta, Carla Renata Sanomiya 29 May 2014 (has links)
Com o surgimento da Tomografia Computadorizada de Feixe Cônico (TCFC) foi possível observar estruturas anatômicas que antes não eram visualizadas em radiografias convencionais, como a foramina lingual lateral (FLL). A FLL é um orifício localizado na região posterior lingual da mandíbula que se comunica com o canal mandibular (CM). O objetivo do estudo foi avaliar a presença da FLL em 100 exames de TCFC obtidas pelo aparelho i-CAT Classic®. A presença da FLL foi comparada entre gênero e idade. As FLL foram localizadas em pacientes dentados através de 5 áreas: primeiro pré-molar inferior (A), segundo pré-molar inferior (B), primeiro molar inferior (C), segundo molar inferior (D) e terceiro molar inferior (E). Foram realizadas as medidas de diâmetro axial (DA), diâmetro coronal (DC) e a distância de FLL ao forame mentual (FLL-FM), e FLL à borda inferior da mandíbula (FLL-BI). A FLL estava presente em 39% (39/100) dos exames e foram encontradas 52 FLL (26 exames unilaterais e 13, bilaterais). O lado direito apresentou 29 FLL, enquanto o lado esquerdo 23. A região onde mais foi encontrada FLL foi a região B. 21 foraminas foram encontradas na posição lingual ao FM. O valor médio do DA foi de 1,26±0,57 mm e do DC de 1,82±1,12 mm. Os valores médios da distância de FLLFM e FLL-BI foram 12,74±7,7 e 5,82±2,78 mm, respectivamente. Não houve diferença estatisticamente significante da presença da FLL entre a idade ou o sexo. A medida FLL-FM foi maior em homens tanto do lado direito como do lado esquerdo, mostrando uma diferença estatisticamente significante (p=0,032). / Cone-beam Computed Tomography (CBCT) allowed viewing some anatomical structures that were not noted in bi-dimensional images, such as lateral lingual foramina (LLF). LLF is an aperture located in posterior lingual mandible area, linked with mandibular canal (MC). The present study evaluated the LLF presence through 100 CBCT images, obtained by i-CAT Classic®. Presence or absence of LLF was compared between sex and age. The LLF was located in dentate patients through 5 areas: first lower pre-molar (A), second lower pre-molar (B), first lower molar (C), second lower molar (D) and third lower molar (E). Was measured axial diameter (AD) and coronal diameter (DC), and, the distance from LLF to mentual foramen (LLF-MF) and from LLF to lower mandible border (LLF-LMB). These measures were also compared between gender. LLF was observed in 39% of the exams (39/100). Fiftytwo LLF were found (26 unilateral and 26 bilateral). Right and left sides presented 29 LLF and 23 LLF respectively. The most prevalent area of LLF occurrence was B area. 21 LLF was located in lingual position of MF. The mean average of AD was 1,26±0,57 mm, and CD was 1,82±1,12 mm. The mean average values of LLF-MF and LLF-BI distances were 12,74±7,7 and 5.82±2,78 mm, respectively. There was no statistical difference of gender or age correlated with LLF presence. Men have LLFMF distance greater than woman, showing no statistically significant difference (p=0,032).
307

Ultrassom de alta frequência para avaliação da tábua óssea vestibular de implantes dentais / High frequency ultrasound for evaluation of buccal bone surrounding dental implants

Bohner, Lauren Oliveira Lima 25 July 2017 (has links)
Objetivo: Avaliar a exatidão do ultrassom de alta frequência na mensuração das dimensões lineares tanto da tábua óssea vestibular como de defeitos periimplantares circundando implantes dentais. Materiais e Métodos: Em uma primeira etapa, implantes dentais (n=10) foram instalados na maxila de 3 crânios secos e escaneados com ultrassom de alta frequência (UAF) e tomografia computadorizada de feixe cônico (TCFC). As seguintes medidas lineares foram determinadas para avaliação: A) espessura óssea; B) nível ósseo. As medições foram comparadas com valores de referência determinados pela microscopia óptica. A segunda etapa do experimento envolveu amostras de osso porcino contendo defeitos ósseos ao redor dos implantes dentais (n=10), as quais foram escaneadas com ultrassom de alta frequência e tomografia computadorizada de feixe cônico. As seguintes medidas foram realizadas nos defeitos periimplantares: A) componente supra-alveolar, B) componente intra-ósseo e C) espessura do defeito. Os valores de referência foram determinado pela microtomografia computadorizada e o erro de medição (diferença entre grupo teste e controle) foi determinado. Os dados foram analisados estatisticamente considerando um nível de significância de p<=0.05. Resultados: Não houve diferença estatisticamente significante entre os grupos para as medições da espessura óssea e nível ósseo (p>0.05). Em relação à espessura óssea, a discrepância foi de 0.17mm para o UAF e 0.02mm para a TCFC. Para o nível ósseo, a discrepância foi de 0.55mm para o UAF e 0.12mm para a TCFC. Ao considerar o erro de medição dos equipamentos na mensuração de defeitos periimplantares, não houve diferença estatisticamente significante entre o UAF e TCFC (UAF= 0.54±0.69mm; TCFC= 0.62±0.55mm). Conclusão: O ultrassom de alta frequência apresentou exatidão para a mensuração das dimensões lineares da tábua óssea vestibular e de defeitos periimplantares circundando implantes dentais. / Purpose: To evaluate the accuracy of a high frequency ultrasound scanner (HFU) to the measurement of buccal bone and periimplant defects surrounding dental implants. Materials and Methods: The first phase of this study comprised the installation of dental implants (n=10) in the maxillary of 3 dry skulls. The dental implants were scanned with a high frequency ultrasound scanner and a cone-beam computed tomography (CBCT). The following measurements were determined for evaluation: A) bone thickness, and B) bone level. The measurements were compared with reference values determined by an optical microscopy. The second phase comprised the installation of dental implants (n=10) in porcine bone samples containing bone defects surrounding dental implants. The bone samples were scanned with a high frequency ultrasound and cone-beam computed tomography and the following measurements were performed: A) supra-alveolar component, B) intra-bony component and C) thickness. The reference values were determined by a micro-computed tomography and the measurement error (difference between experimental and control group) was determined for each group. All measurements were statistically analyzed with a significance level of p<=0.05. Results: There was no statistically significant difference between ultrasound and cone-beam computed tomography for the measurement of buccal bone (p>0.05). With regard to the bone thickness, the discrepancy to the reference values was 0.17mm for HFU and 0.02mm for CBCT. For bone level, the discrepancy was 0.55mm for HFU and 0.12mm for CBCT. The measurement error from both the devices not differed statistically (HFU= 0.54±0.69mm; CBCT= 0.62±0.55mm). Conclusion: The high frequency ultrasound presented accuracy for the measurement of buccal bone and periimplant defects surrounding dental implants.
308

Estudo dos canais alveolares superiores e do canal infra-orbital por meio da tomografia computadorizada de feixe cônico / Study of the superior alveolar canals and infraorbital canal using cone beam computed tomography

Nicolielo, Laura Ferreira Pinheiro 23 August 2013 (has links)
Para oferecer mais informações aos cirurgiões no planejamento de intervenções cirúrgicas maxilofaciais, o presente estudo teve como objetivo avaliar a presença, localização e tamanho dos canais alveolares superiores (CAS), anterior (CASA) e posterior (CASP), canal infra-orbital (CI) e forame infra-orbital (FI) em imagens de tomografia computadorizada de feixe cônico (TCFC) de 100 pacientes adultos (&#x2265; 20 anos), obtidas pelo aparelho i-CAT Classic®. Um examinador calibrado observou a presença dos CAS, CI e FI bilateralmente. Quando presentes, eram medidos comprimento (parte descendente, parte do assoalho da órbita e total), largura e altura do CI; altura, largura e distância ao rebordo inferior da órbita (RIO) do FI; distância da borda inferior dos CAS a crista do rebordo alveolar em 5 regiões: canino (CAN), primeiro pré-molar (1PM), segundo pré-molar (2PM), primeiro molar (1M) e segundo molar (2M); e os diâmetros dos CAS. Foram também observados a localização dos CAS em relação ao seio maxilar e a presença de reparos anatômicos como canal duplo/múltiplo, anastomose intra-óssea e extensão do CASA para a abertura piriforme. Associações entre homens e mulheres, lados direito e esquerdo e regiões foram investigadas para todas as medidas e visibilidade, utilizando separadamente os métodos estatísticos. A presença do CI e FI foi de 100%. A visibilidade do CASA/CASP foi de: 99%/0% (CAN), 99%/21% (1PM), 89%/41% (2PM), 46%/44% (1M) e 7%/61% (2M). As médias dos comprimentos da parte descendente, da parte do assoalho da órbita e total do CI foram de 8,82mm, 19,44mm e 28,35mm, respectivamente. Altura e largura médias do CI foram, respectivamente, 2,08mm e 3,91mm. As médias da altura, largura e distância ao RIO do FI foram: 4,43mm, 5,18mm e 7,52mm, respectivamente. As distâncias médias do CASA ao rebordo alveolar foram: 18,54mm (CAN), 25,47mm (1PM), 28,43mm (2PM), 30,78mm (1M) e 33,21mm (2M); e do CASP: 22,3mm (1PM), 17,65mm (2PM), 15,34mm (1M) e 16,87mm (2M). As médias dos diâmetros do CASA e do CASP foram 0,90mm e 0,83mm, respectivamente, sendo que 77,5% dos CASA e 82% dos CASP eram &#x2264; 1mm e 22,5% dos CASA e 18% dos CASP eram entre 1-2 mm. Em relação ao seio maxilar, 53% e 44% dos CASA foram encontrados no terço superior e médio, respectivamente, e 64% e 36% dos CASP foram encontrados no terço inferior e médio, respectivamente. Houve diferença estatisticamente significativa (p<0,05) entre homens e mulheres para o comprimento, altura e largura do CI; para a altura, largura e distância ao RIO do FI; e para as distâncias dos CAS ao rebordo alveolar. CASA duplo, anastomose intra-óssea e extensão do CASA para a abertura piriforme foram detectados em 24,5%, 38,5% e 84% dos casos, respectivamente. A localização da anastomose foi teve maior ocorrência entre o CAN e 1PM (43%). Os resultados sugerem que a TCFC seja uma ferramenta adequada para examinar os CAS, CI e FI no planejamento de procedimentos cirúrgicos do terço médio da face, a fim de evitar danos a estruturas neurovasculares importantes. / To provide more information to clinicians in planning maxillofacial surgical interventions, the present study evaluated the presence, location and size of the superior alveolar canals (SAC), anterior (ASAC) and posterior (PSAC), infraorbital canal (IC) and infra-orbital foramen (IF) in cone beam computed tomography (CBCT) of 100 adult patients (&#x2265; 20 years old), obtained by i-CAT Classic®. One calibrated examiner observed SAC, IC and IF presence, bilaterally. When present, were measured: length (descending part, orbital floor part and total), width and height of the IC, height, width and distance from the IF to the inferior orbital rim (IOR), distance from the lower border of SAC to the alveolar crest in 5 regions: canine (CAN), first premolar (1PM), second premolar (2PM), first molar (1M) and second molar (2M); and the diameters of SAC. It was also observed the location of SAC in relation to the maxillary sinus floor and the presence of anatomical landmarks such as doble/multiple canal, intraosseous anastomosis and ASAC extension to the piriform aperture. Associations between men and women, right and left sides and regions were investigated for all measurements and presence using statistical methods separately. The presence of the IC and IF was 100%. The presence of ASAC/PSAC was: 99%/0% (CAN), 99%/21% (1PM), 89%/41% (2PM), 46%/44% (1M) e 7%/61% (2M). The mean lengths of the IC descending part, IC orbital floor part and total lenght of the IC were 8.82mm, 19.44mm and 28.35mm, respectively. The mean height and width of the IC were, respectively, 2.08mm and 3.91mm. The mean height, width and distance to the IOR of IF were: 4.43mm, 5.18mm and 7.52mm, respectively. The mean distances of ASAC to the alveolar crest were: 18.54mm (CAN), 25.47mm (1PM), 28.43mm (2PM), 30.78mm (1M) and 33.21mm (2M); and of PSAC: 22.3mm (1PM), 17.65mm (2PM) 15.34mm (1M) and 16.87mm (2M). The mean diameters of ASAC and PSAC were 0.90mm and 0.83mm, respectively, and that, 77.5% of ASAC and 82% of PSAC were &#x2264; 1mm and 22.5% of ASAC and 18% of PSAC were between 1-2 mm. In relation to the maxillary sinus, 53% e 44% of the ASAC were found in the upper and middle third of maxillary sinuses, respectively, and 64% and 36% of the PSAC were found in lower and middle third, respectively. There was a statistically significant difference (p<0.05) between men and women for the length, height and width of the IC, for the height, width and distance to the IOR of IF, and for distances of SAC to the alveolar crest. Double ASAC, intraosseous anastomosis and ASAC extension to the piriform aperture were present in: 24.5%, 38.5% and 84% of the cases, respectively. The location of the anastomosis had more incidence between the CAN and 1PM (43%). The results suggest that CBCT is a suitable tool to evaluate the SAC, IC and IF, assisting surgeons in planning surgical procedures of the midface, in order to avoid damage to important neurovascular structures.
309

Avaliação dos efeitos do Sistema Damon nas inclinações dentárias, dimensões dos arcos e suporte ósseo alveolar por meio da tomografia computadorizada de feixe cônico / Changes in arch dimensions, buccolingual inclinations and alveolar bony support during alignment using Damon MX: a CBCT study

Juliana Fernandes de Morais 28 November 2012 (has links)
Avaliação dos efeitos do Sistema Damon nas inclinações dentárias, dimensões dos arcos e suporte ósseo por meio da tomografia computadorizada de feixe cônico Este estudo objetivou analisar as alterações nas inclinações vestibulolinguais dos dentes, nas dimensões dos arcos e nas espessuras das tábuas ósseas vestibulares durante o alinhamento com Sistema Damon, como também identificar fatores pré-tratamento (espessura óssea inicial, larguras dos arcos, apinhamento) e alterações do tratamento (expansão dos arcos, vestibularização dos dentes) possivelmente associados. Vinte e dois adolescentes com dentadura permanente completa até primeiros molares, tratados sem extrações e apinhamento inicial mínimo de 4mm superior: -6,71mm (DP 2,99), inferior: -5,12mm (DP 2,03) foram escaneados por tomografia computadorizada de feixe cônico (TCFC) antes (T0) e após (T1) o alinhamento com o Sistema Damon. As dimensões dos arcos e as inclinações vestibulolinguais dos dentes foram avaliadas a partir das TCFC (T0 e T1) em modelos 3D e cortes multiplanares, enquanto o apinhamento foi mensurado nos modelos de estudo (T0). A spessura das tábuas ósseas vestibulares nos ¾ coronais e ¼ apical da raiz dentária foram mensuradas por meio de imagens de tomográficas parassagitais (0,3mm de espessura) das duas fases T0 e T1, nas áreas de incisivos centrais superiores e de segundos pré-molares e primeiros molares superiores e inferiores. As variáveis foram submetidas ao teste de de Shapiro-Wilk para testar sua distribuição. As alterações de todas as variáveis de T0 para T1 foram comparadas por meio dos testes t pareado ou de Wilcoxon. A correlação entre as alterações das espessuras ósseas com os possíveis fatores associados foi verificada pelo coeficiente de correlação de Pearson ou teste de correlação de Spearman. O alinhamento com o Sistema Damon produziu expansões dos arcos associados à proclinação dos dentes e à redução na espessura óssea vestibular. As tábuas ósseas vestibulares tornaram-se não mensuráveis com o alinhamento em 25% das raízes mesiovestibulares dos primeiros molares superiores. A redução nas espessuras ósseas vestibulares mensuráveis, recobrindo os ¾ coronais da raiz, foi significante nas áreas de incisivo central superior (-13,22%), raiz mesiovestibular do primeiro molar superior (-20,54%) e raízes mesial e distal do primeiro molar inferior (-15,58% e -11,38%, respectivamente). Houve tendência ao aumento da espessura óssea vestibular da raiz distovestibular do primeiro molar superior (p= 0,051), provavelmente devido à rotação do molar com o alinhamento. A redução na espessura óssea vestibular durante o alinhamento dentário mostrou correlação positiva com a espessura óssea e apinhamento iniciais no arco superior, bem como com a distância inter-segundos-prémolares pré-tratamento no arco inferior. Os arcos mais expandidos durante a fase de alinhamento tenderam a sofrer maior redução nas espessuras ósseas vestibulares. Conclui-se que o Sistema Damon produz expansões dos arcos associados à redução óssea vestibular durante a fase de alinhamento. Dentes com ossos mais finos e apinhamentos mais severos antes do tratamento apresentam maior risco para redução na tábua óssea vestibular e a quantidade de expansão durante o tratamento pode potencializar esse efeito. / This study aimed first to assess the changes in teeth buccolingual inclinations, arch dimensions, and buccal bony plate thicknesses occurred during the alignment phase using a self-ligating brackets system (Damon MX). Secondly, to identify pre-treatment (initial bone thickness, initial arch widths, initial crowding) or treatment parameters (amount of expansion, amount of buccal tipping) that could act as risk predictors for buccal bone reduction during orthodontic treatment. Twenty-two adolescents with complete permanent dentition until first molars, minimum initial crowding of 4mm - maxillary: -6.71 mm (SD 2.99), mandibular: - 5.12 mm (SD 2.03) - treated without extractions were scanned by cone beam computed tomography (CBCT) before (T0) and after (T1) alignment using Damon System. Arch dimensions and teeth buccolingual inclinations were evaluated by means of digital models and multiplanar reconstructed images both obtained from CBCT (T0 and T1), crowding was measured on study casts (T0). Alveolar buccal bone thickness overlying the ¾ coronal and the ¼ apical of the root were measured in the areas of maxillary central incisors, as well as maxillary and mandibular premolars and first molars by means of cross-sectional images reconstructed with 0.3 mm thickness at T0 and T1, Distribution of the variables was verified by Shapiro-Wilks test. Changes in all variables from T0 to T1 were compared using paired t test or Wilcoxon test. The correlation between changes in bone thickness with its possible associated factors was assessed by Pearson correlation coefficient or Spearman correlation test. Alignment using Damon System produced substantial arch expansion associated with proclination of teeth and reduction in buccal bone thickness. The buccal bone plates overlying 25% of the mesiobuccal roots of the maxillary first molars became unmeasurable during the alignment phase. The reduction in the measurable buccal bone thickness, overlying the ¾ coronal root length, was significant in the areas of maxillary central incisor (-13.2%), mesiobuccal root of maxillary first molar (-20.5%), mesial and distal roots of mandibular first molar (-15.6% and -11.4%, respectively). There was a tendency for increasing buccal bone thickness root overlying the distobuccal root of maxillary first molar (p = 0.051), probably due to molar rotation during the alignment phase. The reduction in buccal bone thickness during alignment with Damon System showed a positive correlation with initial bone thickness and initial crowding in the maxillary arch, and the pre-treatment inter-secondpremolar width in the mandibular arch. The more expanded the arch during the alignment phase, the greater reduction in buccal thickness bone. It is concluded that the Damon system produces arch expansion associated with decrease in buccal bone thickness during the alignment phase. Thinner buccal bony plates and more severe crowding before treatment increase the risk for buccal bone reduction and the amount of expansion during treatment may further enhance this effect.
310

Relação entre o movimento ortodôntico vestibular dos incisivos inferiores e características do osso alveolar vestibular e lingual: avaliação por meio da tomografia computadorizada cone-beam / Labial movement of the mandibular incisors and tomographic characteristics of the labial and lingual alveolar bone

Carolina Carmo de Menezes 14 November 2014 (has links)
Introdução: O objetivo principal desta pesquisa foi avaliar as características do osso alveolar vestibular e lingual, na região ântero-inferior, em pacientes que realizaram tratamento ortodôntico corretivo não cirúrgico da má oclusão de Classe II. Material e Métodos: A amostra foi constituída de 32 pacientes divididos de acordo com a inclinação vestibular dos incisivos inferiores em dois grupos: Grupo Experimental que protruíram ou inclinaram os incisivos para vestibular em 1,5 mm e/ou 10o ou mais e Grupo Controle que protruíram ou inclinaram os incisivos para vestibular menos de 1,5 mm e/ou 10o. Estes grupos foram compatibilizados de acordo com a idade, sexo e padrão facial. O nível da crista óssea alveolar vestibular e lingual, a espessura da tábua óssea vestibular e lingual na metade e no ápice radicular, assim como a presença ou ausência de deiscências e fenestrações foram avaliados nos cortes parassagitais em imagens de tomografia computadorizada cone-beam, realizadas após um ano da remoção do aparelho fixo, na região dos seis dentes anteriores inferiores. A comparação intergrupos foi realizada por meio do teste t e o teste de Mann-Whitney para as avaliações quantitativas e pelo teste Exato de Fisher para as avaliações qualitativas (p<0,05). Verificou-se a correlação entre as medidas quantitativas e a quantidade de protrusão/inclinação vestibular dos incisivos inferiores por meio dos testes de Pearson e de Spearman. Resultados: O grupo experimental demonstrou espessura da tábua óssea vestibular no nível apical maior para os incisivos centrais, e espessura da tábua óssea lingual no nível apical menor para os incisivos centrais, laterais e caninos, em relação ao grupo controle. Maior número de deiscências na lingual dos incisivos centrais e fenestrações na vestibular dos incisivos laterais foi encontrado para o grupo experimental em comparação ao grupo controle. No nível apical dos incisivos centrais e caninos, quanto maior a quantidade de inclinação vestibular e protrusão dos incisivos inferiores durante o tratamento, menor espessura da tábua óssea lingual e maior espessura da tábua óssea vestibular. Conclusões: O grau de protrusão dos incisivos inferiores apresentou influência sobre a espessura da tábua óssea ao nível do ápice radicular dos dentes anteriores. Somente deiscências linguais e fenestrações ósseas vestibulares foram observadas com mais frequência no grupo tratado com significante protrusão dos incisivos. / The aim of this study was to assess the morphology of the mandibular incisors labial and lingual alveolar bone in patients who underwent Class II nonsurgical orthodontic treatment. The sample comprised 32 patients who were divided into two groups according to the amount of labial protrusion of the mandibular incisors: the experimental group (EG) - which protruded or labially tipped the incisors 1.5 mm and/or 10o or more; and the control group (CG) - which protruded or labially tipped the incisors less than 1.5 mm and/or 10o. These groups were matched according to age, sex and facial pattern. Measurements of the vertical alveolar bone level and alveolar bone thickness of the labial and lingual plate, as well as the presence and absence of dehiscences and fenestrations were evaluated in cone-beam computed tomography cross-sectional images of the six mandibular anterior teeth, taken one year after appliance removal. Intergroup comparisons were performed using Mann-Whitney and t tests for quantitative assessments and Fisher Exact Test for qualitative assessments. Correlation between quantitative measures and the amount of protrusion/labial inclination of the mandibular incisors was evaluated with Pearson and Spearman tests. The experimental group showed significant greater thickness of the apical buccal bone plate of the central incisors and smaller thickness of the apical lingual bone plate of the central incisors, lateral incisors and canines. Greater number of lingual dehiscences in the central incisors and labial fenestrations in the lateral incisors was found for the experimental group. At the apical level of the central incisors and canines, the greater the amount of labial inclination and protrusion of the mandibular incisors during treatment, the smaller was the lingual bone plate thickness and greater was the thickness of the labial bone plate. The protrusion degree of the mandibular incisors influenced the apical bone plate thickness of the anterior teeth. Only lingual dehiscences and labial bone fenestrations were more frequently observed in the group treated with significant protrusion of the incisors.

Page generated in 0.04 seconds