• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 477
  • 326
  • 44
  • 43
  • 20
  • 11
  • 7
  • 6
  • 5
  • 5
  • 4
  • 4
  • 3
  • 3
  • 3
  • Tagged with
  • 1116
  • 489
  • 447
  • 405
  • 327
  • 326
  • 292
  • 292
  • 87
  • 87
  • 75
  • 69
  • 67
  • 62
  • 62
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
321

Intensidade de pixel e sua correlação com o índice de qualidade óssea de mandíbulas atróficas / Pixel intensity and its correlation with bone quality index of atrophic mandibles

Zambrana, Jessica Rabelo Mina 20 May 2016 (has links)
O sucesso do tratamento de implantes dentários depende da quantidade e qualidade óssea da área de interesse e o uso da Tomografia Computadorizada por Feixe Cônico (TCFC) pode ser correlacionado para a sua estimativa. O objetivo deste estudo foi avaliar e comparar os níveis de escala de cinza dos voxels de imagens obtidas por TCFC de mandíbulas atróficas com o auxílio de programa para diagnóstico e planejamento de implantes e correlacionar a Intensidade Pixel (IP) com a classificação subjetiva do Índice de Qualidade Óssea (IQO). Foram avaliadas imagens tomográficas de 10 mandíbulas atróficas obtidas do banco de dados do LAPI-FOUSP (Laboratório para Análise e Processamento de Imagens) que receberam 8 marcações em regiões normalmente utilizadas para colocação de implantes (4 em região anterior e 4 em região posterior), sobre estas foram posicionados fios ortodônticos para padronização dos cortes tomográficos e simular posições ideais de implantes. Cortes transaxiais das áreas demarcadas foram obtidas para visualização e análise de 4 regiões corticais e 3 regiões trabeculares do tecido ósseo de cada corte, para a seleção de área foi utilizada a ferramenta Região de Interesse (ROI) de cada programa. As imagens foram analisadas por 3 programas de planejamento Romexis (Planmeca,Finlandia), XoranCAT® (Xoran Technologies, EUA) e OsiriX® (Free Software Foundation, 32 bits, EUA). Os dados foram submetidos a análise estatística de Correlação de Spearman em um nível de significância de 5% (p<0,05), análise de correlação intraclasse intra-observador e inter-observador pelo teste Kappa ponderado e o teste qui-quadrado. Os resultados apresentaram que os programas Romexis e OsiriX apresentaram melhor acuidade para a avaliação subjetiva de qualidade óssea, em contrapartida o programa Xoran apresentou inconsistência de dados. Concluiu-se que há correlação entre Intensidade de Pixel e Qualidade óssea de acordo com os resultados encontrados para os programas OsiriX e Romexis / The success of dental implants treatment depends on the bone quantity and quality of the area of interest and the use of Cone Beam Computed Tomography (CBCT) can be correlated to an estimative. The aim of this study was to evaluate and compare the grey scale levels of voxels obtained by CBCT of atrophic mandibles with the aid of software for diagnosis and planning implants and correlates the Pixel Intensity (PI) with the subjective classification of Bone Quality Index (BQI). Tomographic images of 10 atrofic mandibles obtained from the data base of LAPI-FOUSP (Laboratory of analysis and imaging processing) were evaluated, received 8 marks in areas normally used for implant placement (4 in anterior and 4 in posterior region) on these orthodontic wires were positioned for standardization of tomographic images and simulate optimal implant positions. Transaxial slices of the demarcated areas were made for visualization and analysis of four regions of interest for cancellous bone and three regions of interest for cortical bone and for selection of each area a tool called Region of Interest (ROI) was used by each software. The images were analised by three diferent planning software, Romexis (Planmeca, Finland), XoranCAT® (Xoran Technologies, EUA) e OsiriX® (Free Software Foundation, 32 bits, EUA). Data were subjected to statistical analysis of Spearman correlation, intraclass intra-observer and inter-observer analysis correlation and weighted Kappa concordance coefficient with 5% significance level and chi-squared test; The results presented that Romexis and OsiriX software showed better accuracy for subjective assessment of bone quality, on the other hand Xoran software showed data inconsistency. This study concluded that a correlation was found between Pixel Intensity (PI) and Bone Quality (BQ) due to the results of OsiriX and Romexis software.
322

Validação de medidas maxilofaciais por meio da tomografia computadorizada por feixe cônico em 3D / Assessment of linear and angular measurements on three-dimensional conebeam computed tomographic images

Moreira, Carla Ruffeil 01 October 2009 (has links)
O objetivo deste estudo foi demonstrar a precisão e a acurácia de medidas maxilofaciais lineares e angulares obtidas por tomografia computadorizada por feixe cônico (TCFC). A amostra consistiu de quinze crânios humanos secos submetidos à TCFC. Medidas lineares e angulares foram realizadas em imagens em terceira dimensão (3D) após a identificação de pontos craniométricos convencionais. As imagens em 3D-TCFC foram analisadas por dois radiologistas, duas vezes, independentemente. Medidas físicas foram realizadas por um terceiro examinador utilizando paquímetro e goniômetro digitais. Os resultados não demonstraram diferenças estatísticas significantes para as análises intra e interexaminadores. As comparações entre as medidas físicas e as obtidas em 3D-TCFC para ambos os examinadores também não foram estatisticamente significantes tanto para as medidas lineares quanto paras as angulares (p= 0,968 e 0,915, p= 0,844 e 0,700, respectivamente). As imagens em 3D-TCFC podem ser utilizadas com precisão e acurácia para a obtenção de medidas lineares e angulares a partir de estruturas anatômicas e pontos craniométricos. / The purpose of this research was to provide further evidence to demonstrate the precision and accuracy of maxillofacial linear and angular measurements obtained by cone-beam computed tomography (CBCT) images. The study population consisted of 15 dry human skulls that were submitted to a CBCT, and threedimensional (3D) images were generated. Linear and angular measurements based upon conventional craniometric anatomical landmarks, were identified in 3D-CBCT images by two radiologists twice each independently. Subsequently physical measurements were made by a third examiner using a digital caliper and a digital goniometer. The results demonstrated no statistically significant difference between inter and intra-examiner analysis. Regarding accuracy test, no statistically significant difference were found of the comparison between the physical and CBCT-based linear and angular for both examiners (p= 0.968 and 0.915, p= 0.844 and 0.700 respectively). 3D-CBCT images can be used to obtain dimensionally accurate linear and angular measurements from bony maxillofacial structures and landmarks.
323

Avaliação da disponibilidade óssea para enxertos, na região posterior da mandíbula, por meio da tomografia computadorizada de feixe cônico / Evaluation of available bone for grafting in the posterior mandible by means of cone beam computed tomography

Grandizoli, Dayane Kemp 07 March 2016 (has links)
O estudo anatômico dos ossos dos maxilares é de extremo interesse devido à elevada demanda por procedimentos cirúrgicos como implantes osseointegrados e cirurgias ortognáticas. Embora uma variedade de substitutos ósseos seja utilizada para restabelecer a quantidade necessária de osso para instalação de implantes, existe um particular interesse em relação aos enxertos ósseos autógenos, que se mostram superiores, principalmente pela previsibilidade e altas taxas de sucesso. O objetivo desse trabalho foi quantificar o volume ósseo disponível na região posterior de mandíbula através da Tomografia Computadorizada de Feixe Cônico. A TCFC permite realizar medições com precisão e é uma ferramenta útil para avaliação préoperatória em cirurgia odontológica, já que o campo de imagem relativamente pequeno limita a exposição do paciente à radiação. Foram analisados 1.500 exames de TCFC e selecionados 70 exames do arquivo de imagens do Departamento de Estomatologia da Faculdade de Odontologia de Bauru, avaliados bilateralmente nas reformatações panorâmica e parassagitais através do software i-Cat Vision®. Na literatura não há consenso entre parâmetros e limites de osso. Dessa forma, foram definidas algumas referências: a distal da coroa do primeiro molar inferior como o limite anterior do enxerto e o local onde a cúspide mais alta dos molares cruza a borda anterior do ramo ascendente da mandíbula como o limite posterior do enxerto. Nessa região avaliou-se comprimento, altura, espessura de osso e volume da cortical óssea vestibular para enxertia óssea. Os resultados mostraram um volume médio de 859,26 mm3, sendo que a espessura média do osso cortical foi de 2,60mm, o comprimento médio foi de 18,98mm e a média de altura de 17,33mm. Esses valores mostram que a região posterior da mandíbula pode ser utilizada com segurança como área doadora de osso autógeno para reconstrução de pequenos defeitos e, usando esta estimativa de disponibilidade óssea, o cirurgião estará mais seguro para enfrentar os desafios da reconstrução maxilofacial. / The anatomical study of the bones of the jaw is of extreme interest due to the high demand for surgical procedures such as dental implants and orthognathic surgery. Although a variety of bone substitutes are used for restoring the necessary amount of bone for implant placement, there is a particular interest in relation to autogenous bone grafts, which are superior primarily by the predictability and high success rates. The aim of the present study was to quantify the bone volume available on the posterior region of the mandible through Cone Beam Computed Tomography. CBCT allows for an accurate measurement and is a useful tool for preoperative evaluations in dental surgery, since the relatively small image field limits the patient\'s exposure to radiation. Thousand five hundred CBCT exams were analyzed and selected seventy exams of the archives of images from the Department of Stomatology, Bauru School of Dentistry, bilaterally assessed in panoramic and parasagittal reformatting through the i-Cat Vision® software. In the literature there is no consensus between parameters and bone limits. Thus, we determined some references: the distal of the first mandibular molar crown as the anterior limit of the graft, and where the highest cuspid of mandibular molars crosses the anterior border of the ascending ramus of the mandible as the posterior limit of the graft. In this region were evaluated length, height, bone thickness and volume of the vestibular cortical bone for bone grafting. The results showed an average volume of 859.26mm3, while the average thickness of cortical bone was 2.60mm, an average length of 18.98mm and an average height of 17.33mm. These values show that the posterior mandible can be safely used as donor area of autologous bone to rebuild small areas, and using this estimate of available bone, the surgeon will be safer to face the challenges of maxillofacial reconstruction.
324

Comportamento de pesos e valores de cargas no corredor São Paulo - Buenos Aires / not available

Sant\'Anna, José Alex 20 March 1997 (has links)
Este trabalho expõe resultados obtidos durante as atividades de uma tentativa para mostrar que \"nos estudos e projetos sobre transportes, no Cone Sul (parte do continente sul-americano abaixo da linha do equador), o aumento do valor agregado aos produtos transportados pode reduzir a expectativa de crescimento da demanda por transporte\". Para isso apreciaram-se conseqüências de avaliação de projetos de transportes depois de implantação de obras e serviços, comentaram-se conceitos e relações sobre infraestrutura de transportes, renda de região, custos de transporte e preço de produtos, logística e armazenagem. Também introduziram-se conceitos e processos para estudo de variação de valores de elementos de séries temporais, o modelo A RIMA. Relatam-se dados sobre a caracterização do Cone Sul, e, a natureza da demanda, configuração de infra-estrutura e listagem de projetos sobre os equipamentos para transporte na região. Expõe-se que entrevistas a técnicos e dirigentes de órgãos de gerência da infraestrutura de transporte no Cone Sul indicam que a análise de regressão é o processo mais comum para estudo de pesos e valores de transporte - e, que entre Brasil e Argentina a qualidade das estimativas é ruim. Conceitos sobre séries temporais foram aplicados a informações sobre a área de influência do Corredor São Paulo - Buenos Aires para mostrar que a relação peso por valor transportado por ano no comércio entre o Brasil e a Argentina pode ser estudada pelo modelo ARIMA - é decrescente ao longo do tempo e mostra o aumento do valor agregado e a redução da expectativa de crescimento da demanda, representada pelo peso transportado através desse eixo. / This work shows lhe results obtained on trying to show that \"plan and projects for transportation at CONE SUL (part of South America below the Equator), the increase in the transported product aggregated value can make the expectance on the growing of the demand for transports decrease\". To do that, consequences of the evaluation of plans on transport after the implementation phase were accessed; concepts and relationships over the infrastructure of transport, in come of the region, cost of transportation and product prices, logistics and warehousing were discussed. Concepts and processes on study of the variation of values on the elements of time series were presented, the so called ARIMA model. Data on the demand, infrastructure configuration and lists of projects on equipment for transportation in region were also presented. Interviews with administrators of infrastructure of transports on the CONE SUL shows that the regression analysis is the most common method used on the study of weights and values of transports, and that the forecasting using data on commerce between Brazil and Argentina is bad. Concepts of time series were applied over information on the influence area of the São Paulo - Buenos Aires corridor to show that the relationship between weight and price average moved per year can be studied with use of the ARIMA model and decrease over the time, showing the increase of aggregated value and the expectance on the growing of the demand, represented by reduction of the transported weight on that corridor.
325

Avaliação da anatomia neurovascular da mandíbula por meio de tomografia computadorizada de feixe cônico / Assessment of neurovascular anatomy of the mandible through cone-beam computed tomography

Santos, Christiano de Oliveira 08 December 2010 (has links)
A prescrição crescente de exames de imagem tridimensionais em Odontologia especialmente para procedimentos cirúrgicos na mandíbula como a inserção de implantes justifica o grande interesse na reavaliação dos reparos anatômicos nas imagens obtidas por tomografia computadorizada de feixe cônico (TCFC). O reconhecimento das variações anatômicas relacionadas à neurovascularização mandibular nestas imagens é de grande importância, uma vez que injúrias a estas estruturas podem resultar em danos, complicações e insucessos cirúrgicos. Este estudo, realizado em três etapas, se propôs a avaliar aspectos relacionados à anatomia neurovascular da mandíbula em imagens de TCFC. Na primeira etapa, avaliou-se a ocorrência de FM adicionais (FMA) e suas características. A prevalência encontrada foi de 9,4% e um total de 32 FMA foi registrado. Destes, 14 possuíam diâmetro correspondente a pelo menos 50% do diâmetro do FM ipsilateral e suas localizações foram variáveis. Dois casos de ausência de FM foram relatados. Na segunda etapa os CM foram avaliados quanto à presença de CM bífidos, alças anteriores do nervo mentual (AA) e corticalização. Também foi avaliado o trabeculado ósseo na região da fóvea submandibular (FSM). A prevalência de CM bífidos foi de 19%. Dos 19 casos observados, 14 estavam associados a FMA. Três casos estavam associados a forames retromolares associados a bifurcações do CM foram observados. Entre 22% e 28% da amostra apresentava AA e de 4% a 8% apresentava extensão anterior da AA significativa, maior que 4mm. Na região da FSM observou-se um trabeculado ósseo diminuído ou ausente na maioria dos casos, associados a maior frequência de ausência de corticalização do CM. Na terceira etapa, a imagem da radiografia panorâmica foi comparada à TCFC na visualização de variações anatômicas relevantes para o planejamento de implantes na região entre os forames. Houve grande discrepância entre os métodos nas observações referentes à presença de AA, canais incisivos e FMA e estimativa de distância segura para colocação de implantes. Conclui-se que a grande variabilidade anatômica relacionada à neurovascularização da mandíbula e limitação da radiografia panorâmica em evidenciar estas variações ressaltam a importância da realização de exames seccionais como os obtidos na TCFC na avaliação pré-operatória da mandíbula, e que as imagens das diferentes reconstruções disponíveis devem ser interpretadas de forma meticulosa e individualizada. / Current increase on prescription of sectional diagnostic imaging for surgical procedures involving the mandible, such as implant placement, has brought much interest in revisiting neurovascular anatomy with cone-beam computed tomography (CBCT) technology recently. Acknowledgement of such anatomical variations is quite important due to possible injuries to these structures leading to surgical complications and failures. The present study was carried out in three phases and aimed to assess different aspects related to neurovascular anatomy of the mandible on CBCT images. For phase one, occurrence of additional mental foramina (AMF) and their features were assessed. Prevalence was 9.4% and a total of 32 AMF were found. The diameter of the AMF was at least 50% the diameter of ipsilateral MF in 14 cases. Location of AMF was quite variable. Two cases showing absence of MF were registered. For phase two, MC was evaluated regarding the presence of bifid MC, anterior loop of the mental nerve (AL), and corticalization. Additionally, the bone trabeculation in the submandibular gland fossa region (SGF) was assessed. Prevalence of bifid MC was 19% (19 cases). Most cases (n=14) was associated with AMF and 3 cases were associated with retromolar foramina. Between 22% and 28% showed AL, and 4%-8% presented anterior extension of AL bigger than 4mm. SGF region presented decreased or absent trabeculation in most cases, which were associated with more frequent absence of MC corticalization. For phase three, panoramic radiographs (PR) were compared to CBCT regarding assessment of anatomical variations relevant for implant planning. Major discrepancies between PR and CBCT observations were noted regarding presence of AL, incisive canal, and FMA, as well as estimation of safe distance for implant placement. It is concluded that major anatomical variability related to mandibular neurovascularization and limitation of PR in displaying such variations point out to the importance of sectional exams, such as CBCT, for pre-surgical planning. Furthermore, images available of different reconstructions must be evaluated carefully and on a case by case basis.
326

Avaliação da posição e morfologia condilar relacionados aos sinais e sintomas de DTMs em pacientes submetidos a cirurgia ortognática /

Pellizzaro, Delise. January 2017 (has links)
Orientador: Guilherme Monteiro Tosoni / Resumo: O presente trabalho teve como objetivo avaliar, por meio de TCFC, a posição, angulação e aspectos morfológicos dos processos condilares relacionados aos sinais e sintomas das disfunções temporomandibulares (DTMs) pré e pós cirurgia ortognática. Foram selecionados 17 pacientes, com deformidades dentofaciais (Classe II e III de Angle) que estivessem em tratamento ortodôntico e com indicação para cirurgia ortognática. Imagens de tomografia computadorizada de feixe cônico (TCFC) foram utilizadas para análise da posição, angulação e aspectos morfológicos dos processos condilares nas reconstruções axial, coronal e sagital, em três tempos: pré-operatório; 15 e 180 dias após a realização da cirurgia. Para a avaliação dos sinais e sintomas de DTMs, os pacientes foram avaliados pelo questionário padrão Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD), sendo aplicado em dois tempos: pré-operatório e 180 dias. As imagens foram analisadas independentemente por 2 radiologistas previamente calibrados (correlação de Pearson de 0,641 para variáveis numéricas e nível de concordância de 68,63% para variáveis dicotômicas). Diferença estatística foi observada nos ângulos axial direito e coronal medial esquerdo entre o pré-operatório vs 180 dias e na distância condilar posterior do lado esquerdo, na reconstrução sagital entre pré-operatório vs 15 dias e 15 dias vs 180 dias. A presença de novos defeitos condilares foram observados em 3 pacientes após 180 dias. Em relação às DT... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to evaluate the position, angulation, morphological aspects of the condylar process and signs and symptoms of temporomandibular disorders (TMDs) before and after orthognathic surgery. Seventeen patients with dentofacial deformities malocclusion (Angle Class II and III) and orthodontically treated who had referred to orthognathic surgery were selected. Cone beam computed tomography (CBCT) images were used to analyze the position, angulation and morphological aspects of the condylar process in the axial, coronal and sagittal reconstructions, in three times: preoperative; 15 days after the surgery and 180 days after the surgery. For the assessment of TMD signs and symptoms, patients were evaluated using the Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD), which was applied in two times: preoperative and 180 days. The images were analyzed independently by two radiologists previously calibrated (Pearson correlation 0.641 for numeric variables and level of agreement of 68.63% for dichotomy variables. Significant statistical difference was observed in the right and left medial coronal angles between the preoperative vs 180 days and the posterior condylar distance of the left side, in the sagittal reconstruction between preoperative vs 15 days and 15 days vs 180 days. The presence of new condylar defects was observed in 3 patients after 180 days. Regarding to TMDs, there was a significant improvement in 4 patients for muscular TMD, 6 f... (Complete abstract click electronic access below) / Doutor
327

Acurácia de medidas lineares em região posterior de mandíbulas obtidas por tomografia computadorizada de feixe cônico através de diferentes protocolos de aquisição / Accuracy of linear measurements in posterior region of mandible obtained by cone beam computed tomography through different acquisition protocols

Renata de Saldanha da Gama 05 August 2013 (has links)
A utilização da tomografia computadorizada de feixe cônico (TCFC) permite avaliar a altura e espessura do osso remanescente para a instalação de implantes. As mandíbulas atrésicas necessitam de maior grau de detalhamento para obtenção de medidas. A autora, no presente estudo, avaliou a influência do tamanho dos voxels (0,125mm e 0,25mm) nas medidas de altura e espessura em 10 mandíbulas desdentadas e atrésicas. Para determinação dos cortes tomográficos no estudo foram utilizados fios metáticos nas regiões posteriores. Após o exame as mandíbulas foram seccionadas e as medidas diretas de altura e espessura foram obtidas pelo uso de paquímetro digital. Os resultados pelo teste ICC demonstraram não haver diferenças estatisticamente significantes entre as medidas realizadas pelos dois examinadores com paquímetro e as tomografias. Concluiu-se que a TCFC é confiável para realização de medidas na mandíbula e que o tamanho do voxel não interferiu no planejamento cirúrgico. / The use of cone beam computed tomography (CBCT) allows to evaluate the height and thickness of the remaining bone for implant placement. The atresic mandible requires higher level of detail for obtaining measurements. The author in the present study evaluates the influence of the voxel size (0.125 mm and 0.25 mm) in thickness and height measurements using 10 edentulous dry mandibles. For determination of the tomographic study were used metallic wires in the posterior regions. After examining, the mandibles were sectioned and direct measures of height and thickness were obtained through digital caliper. The results by ICC test showed no statistically significant differences between the measurements with caliper and tomograms made by two examiners. It was concluded that CBCT is trusted to carry out measurements in mandible and the voxel size did not affect the surgical planning.
328

Tomografia computadorizada por feixe cônico para detecção de lesões incipientes de furca simuladas em mandíbulas suínas maceradas / Cone beam computed tomography for detection of incipient furcation invasion in pig mandibles

Otávio Shoiti Umetsubo 04 July 2011 (has links)
As radiografias intraorais ilustram bem os estágios de reabsorção periodontal nas regiões interproximais. Entretanto, a sobreposição de estruturas dificulta avaliação da perda óssea nas corticais vestibular e lingual. A tomografia computadorizada por feixe cônico (TCFC) é de elevada importância em várias especialidades odontológicas, tais como implantodontia, avaliação de lesões ósseas, estudo da articulação têmporo-mandibular e cirurgia buco-maxilo-facial. A TCFC também tem tido crescente indicação em outras áreas, como a periodontia e endodontia. O objetivo no presente estudo foi a) estabelecer o protocolo de aquisição mais adequado para a detecção de lesões incipientes de furca simuladas quimicamente; e b) avaliar a reprodutibilidade, sensibilidade e especificidade da TCFC, para a finalidade previamente citada. No presente estudo, foram utilizadas 15 mandíbulas suínas maceradas, que apresentavam o segundo molar íntegro e as corticais adjacentes preservadas As simulações de lesões em região de furca foram feitas com aplicação de ácido perclórico a 70%, em até quatro sítios possíveis em cada mandíbula (vestibular do lado direito, lingual do lado direito, vestibular do lado esquerdo, lingual do lado esquerdo) por um examinador participante que não avaliou as imagens. Nos 60 sitios possíveis, foram escolhidos aleatoriamente 20 para as simulações das lesões. Posteriormente, as mandíbulas foram submetidas à TCFC (i-CAT Next Generation) em dois. protocolos de aquição: voxel 0,2 mm e 0,25 mm, ambos com FOV de 6 cm de altura por 16 cm de diâmetro e com 26,9 segundos de tempo. Dois observadores (radiologistas previamente calibrados) avaliaram os exames duas vezes, em ordem aleatória, sob iluminação controlada. Os observadores foram orientados a direcionar a avaliação das regiões dos segundos molares, e questionados se havia lesão ou não nos sítios avaliados. A interpretação das imagens foi realizada em uma estação de trabalho independente localizada no Laboratório de Imagem em Terceira Dimensão da Faculdade de Odontologia da Universidade de São Paulo, utilizando o software Xoran (Xoran Technologies). A sensibilidade, especificidade e reprodutibilidade da TCFC foram avaliadas nos dois protocolos. A TCFC apresentou especificidade alta, sensibilidade baixa e reprodutibilidade moderada na detecção de lesões incipientes de furca. A influência do tamanho do voxel não foi estatisticamente significativa na detecção destas lesões. / Intraoral radiographs illustrate the stages of resorption in periodontal interproximal regions. However, overlapping structures hinders evaluation of bone loss in the buccal and lingual cortical plates. The cone beam computed tomography (CBCT) is of high importance in various dental specialties such as implantology, evaluation of bone lesions, the study of temporomandibular joint and maxillo-facial surgery. The CBCT has also been increasing indications in other areas, such as periodontics and endodontics. The aim of this study was to establish a) the acquisition protocol most suitable for the detection of incipient furcation invasion chemically simulated and b) assess the reproducibility, sensitivity and specificity of CBCT for the purpose previously mentioned. In this study, 15 pigs macerated mandibles were used, which showed the second molar and the adjacent cortical integrity preserved. Simulated lesions in the furcation area were made with application of 70% perchloric acid, up to four possible sites in each jaw (the right buccal, the right lingual, the left buccal, and left lingual side) by an examiner participant who did not evaluate the images. In the 60 possible sites, 20 were randomly chosen for the simulated lesions. Subsequently, the mandibles underwent cone beam computed tomography (Next Generation i-CAT) in two acquisition protocols: at 0.2 mm and 0.25 mm voxel, both with FOV of 6 cm height by 16 cm in diameter and 26.9 seconds of time. Two observers (calibrated radiologists) evaluated the examinations twice, in random order under controlled lighting. Observers were instructed to direct the evaluation to the regions of the second molars, and they were asked if there were or not injuries on those avaluated sites. Image interpretation was performed on an independent workstation located at the Third Dimension Laboratory of Image in the School of Dentistry, University of São Paulo, using the software Xoran (Xoran Technologies). The sensitivity, specificity and reproducibility of CBCT were assessed in both trials. The CBCT showed high specificity, low sensitivity and moderate reproducibility in the detection of incipient lesions, furcation. The influence of voxel size was not statistically significant in detecting these lesions.
329

\"Estudo comparativo entre a tomografia computadorizada e a tomografia volumétrica na confecção de modelos de prototipagem\" / Comparison of cone beam computerized tomography and multislice computerized tomography for building rapid prototyping models

Mario Sergio Saddy 07 December 2006 (has links)
O objetivo neste estudo foi comparar modelos de prototipagem, originados a partir de dados obtidos em exames de tomografia volumétrica (TV) e tomografia computadorizada (TC), a fim de verificar a precisão de reprodutibilidade destas tecnologias. Uma mandíbula seca foi submetida aos exames de TV (NewTom 9000? QR, Itália) e TC (Select SP-Elscint, Israel). Os dados obtidos nos exames foram manipulados em dois sistemas de tratamento de imagem, o 3D- Analyze (Mayo Clinic, E.U.A.) e o InVesalius (CenPRA, Brasil) e confeccionados protótipos, em duas diferentes tecnologias (SLS - sinterização seletiva a laser e 3DP - impressão tridimensional). A mandíbula seca (padrão ouro) e os oito conjuntos de protótipos gerados, sendo I-TC-Analyze?3DP; II-TC-Invesalius?3DP; III-TC-Analyze?SLS; IVTC- Invesalius-SLS; V-TV-Analyze?3DP; VI-TV-Invesalius?3DP; VIII-TV-Analyze? SLS; VIII-TV-Invesalius-SLS, foram submetidos a processos de engenharia reversa com a finalidade de digitalizar as superfícies dos objetos para uma comparação de cada modelo de prototipagem produzido com o padrão ouro, com precisão de 0,001mm. Os desvios de até 1mm e até 2mm foram calculados, comparados e analisados estatisticamente os erros percentuais. Os modelos de prototipagem rápida originados por meio da obtenção de dados de exames de tomografia computadorizada são mais precisos que os modelos de prototipagem originados por meio de dados de exames de tomografia volumétrica. / The purpose of this study is to compare rapid prototyping models created from cone beam computerized tomography (CBCT) and multislice computerized tomography (CT) data, in order to verify the accuracy of these technologies. A dry skull mandible was submitted in a CBCT (NewTom ? QR, Italy) and CT (Select SP-Elscint, Israel) exams. The tomographies data were processed by two different Medical Image processing systems, 3D-Analyze (Mayo Clinic, U.S.A.) and InVesalius (CenPRA, Brazil). Rapid prototypes models were built in two different rapid prototyping technologies, 3D Printer (3DP) and Selective Laser Sintering (SLS). The dry skull mandible (gold standard) and the eight prototypes, as follows; I-CT-Analyze?3DP; IICT- Invesalius?3DP; III-CT-Analyze?SLS; IV-CT-Invesalius-SLS; V-CBCT-Analyze? 3DP; VI-CBCT-Invesalius?3DP; VIII-CBCT-Analyze?SLS; VIII-CBCT-Invesalius-SLS, were submitted to a reverse engineering process aimed to digitalize the surfaces of the objects to compare each rapid prototype model with the gold standard with a precision of 0.001mm. Percentage deviations errors until 1.0mm and 2.0mm were calculated, compared and statistically analyzed. The prototyped models obtained with multislice computerized tomography data shows more accuracy than those obtained with data from cone beam computerized tomography.
330

Estudo dos parâmetros de estabilidade de travamento entre implante dentário e componente protético através do sistema cone Morse / Study on the stability parameters of locking between dental implants and prosthetic component system through the Morse taper

Luís Cláudio Aranha 05 December 2014 (has links)
Na implantodontia visa-se dois grandes resultados para os desdentados parciais e totais, função mastigatória e estética. Ambos têm o mesmo grau de importância, para tanto se deve pensar no que se tem de mais seguro e prático nos dias de hoje. O cone Morse, na implantodontia oral, é um sistema de estabilidade entre o implante dentário e o parafuso intraósseo de sustentação. Para seu correto uso se faz necessário uma série de análise de suas características e condições. No presente trabalho focou-se em desenvolver protocolo de validação de torque, além de analisar parâmetros de acabamento, deformação e estabilidade précarga e pós-carga dentro de protocolos já recomendados. Avaliou-se sua condição antes e após os efeitos de carga mastigatória simulada por ensaio de fadiga. Concluiu-se que o uso do cone Morse dentro dos protocolos indicados deve ser revisto quanto a padrões similares de torque nos pilares sólidos e indexados, cada um possui limites e indicações diferentes para se manter estável. Concluiu-se também que não é um sistema totalmente livre de trânsito de bactérias e que esse trânsito aumenta de forma proporcional ao uso e força mastigatória, indicando que melhorias no acabamento entre as peças devem ser implementadas e/ou adição de material que afaste crescimento bacteriano priorizando a saúde do periodonto e do tecido ósseo de sustentação mantendo o sistema seguro em longevidade. / In implantology it is aimed two major outcomes for the partial and total toothless persons, mastigatory function and aesthetics. Both have the same degree of importance, therefore it must be thought about what is safer and more practical these days. Morse taper in oral implantology is a system of stability between the dental implant and the intraosseous screw support. For its correct use a series of analysis of its features and conditions is required. This work was focused on developing torque validation protocol, and analyzing surface finishing parameters, deformation and stability as before load and after load in recommended protocols. The implants condition before and after the effects of habitual masticatory load was simulated by fatigue testing. It was concluded that the Morse taper use within the specified protocols should be reviewed for similar patterns of torque in solids and indexed pillars, each has different limits and signs to remain stable. It was also concluded that it is not a traffic totally free system of bacteria and that this influence increases in proportion to the use and masticatory forces, improvements in the surface finish between parts and / or addition of material that hinders bacterial growth is needed if it is prioritized the health of the periodontium and the bone tissue keeping the system safe in the long therm.

Page generated in 0.0424 seconds