• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 477
  • 326
  • 44
  • 43
  • 20
  • 11
  • 7
  • 6
  • 5
  • 5
  • 4
  • 4
  • 3
  • 3
  • 3
  • Tagged with
  • 1116
  • 489
  • 447
  • 405
  • 327
  • 326
  • 292
  • 292
  • 87
  • 87
  • 75
  • 69
  • 67
  • 62
  • 62
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
291

[en] DEVELOPMENT OF A METHODOLOGY FOR THE DETERMINATION OF THE SOIL VISCOSITY / [pt] DESENVOLVIMENTO DE UMA METODOLOGIA PARA DETERMINAÇÃO DA VISCOSIDADE DE SOLOS

MANUELLA SUELLEN VIEIRA GALINDO 19 May 2014 (has links)
[pt] Este trabalho apresenta o desenvolvimento de uma metodologia para determinação experimental da viscosidade de solos, visando subsidiar estudos associados ao desenvolvimento de corridas de massa. Este parâmetro reológico é importante não somente para a determinação dos valores de velocidade, como também para a delimitação de áreas a serem afetadas por tal tipo catastrófico de movimento. Para o alcance do referido objetivo, foi desenvolvido um equipamento a partir de adaptações no conjunto de abatimento de tronco de cone, utilizado para a realização de estudos em concreto, e estabelecida uma metodologia padrão a ser empregada nos ensaios voltados para a determinação da viscosidade em solos. De posse da taxa de cisalhamento, grandeza variável em função da umidade do material e obtida como resultado do ensaio realizado no equipamento desenvolvido, foram realizados testes reológicos em reômetro placaplaca e viscosímetro de Brookfield, buscando-se correlacionar umidade, taxa de cisalhamento e viscosidade. Foram analisados quatro solos de litologias diferentes, o que permitiu uma boa espacialização dos resultados obtidos, culminado com a determinação de uma equação em que a viscosidade pode ser estimada em função da taxa de cisalhamento. / [en] This research presents a proposal for experimental determination of the soil viscosity in order to evaluate the development of debris flows. This rheology parameter is important for determining not only the velocity values, but also to delimitate the area to be affected by a debris flow. For this, a device was developed from adaptations in slump test, used for studies on concrete, and established a standard methodology to be used in tests aimed at determining the viscosity in soils. In possession of the shear rate, which varies depending on soil moisture, obtained as a result of the test performed on the equipment developed rheological tests were performed on plate-plate rheometer and Brookfield viscometer. After that, correlations of the soil moisture, the shear rate and the viscosity of each sample were established. At total, four different lithologies of soil were analyzed, which allowed a good spatial distribution of the results, culminating in the determination of an equation in which the viscosity can be estimated as a function of the shear rate.
292

Competitive biosorption of a mixture of cationic dyes from a multicomponent solution using modified pine cone powder

Ngema, Silindile Lucia 07 1900 (has links)
The biosorption of methyl violet and methylene blue onto modified pine cone powder was studied. Single and binary component systems studies were carried out for the biosorption of methyl violet and methylene blue onto raw, Fenton treated and acrylic acid grafted pine cone powder. Various experimental parameters were studied including initial dye concentration (200-900 mg/dm3), contact time, solution pH (4-12), mass of adsorbent (0.05-0.30g) and temperature (25-45 °C). Pseudo-first order and pseudo-second order equations were used to analyze the kinetic data. It was found that the data follow the pseudo -second order kinetic model for all temperature studied. The experimental data were analyzed using Langmuir and Freudlich isotherm model. The biosorption of methyl violet and methylene blue showed a better fit to Langmuir isotherm which properly describes the experimental data and that the sample surfaces are homogeneous. Various thermodynamic parameters, such as Gibbs energy (ΔG*), enthalpy change (ΔH*) and entropy change (ΔS*), were calculated which indicated the present system was spontaneous and exothermic process for methyl violet and methylene blue. It was found that enthalpy and entropy of acrylic acid grafted pine cone was higher as compared to raw and Fenton‘s reagent for methyl violet and methylene blue. Raw, Fenton treated and acrylic acid pine cone powder were characterized with Fourier transform infrared spectroscopy (FTIR), Ultraviolet-visible spectroscopy (UV-VIS), Thermogravimetic analysis (TGA/DTA), X-ray Diffraction (XRD) and Brauner, Emmett and Teller (BET). The following parameters were used to determine the surface properties of the grafted pine cone: change in H+ concentration and oxidation reduction potential (ORP), surface negative charge, bulk density and acid number measurements. The FTIR analysis confirmed the presence of the organic compounds on the raw, Fenton treated and acrylic acid grafted pine cone powder. The UV/VIS determined the percentage removal of dyes from aqueous solution in single and binary component systems by comparing the raw, Fenton treated and Acrylic acid grafted pine cone powder. Thermo gravimetric analysis confirmed the reactions which occur at the molecular level of the raw, Raw + KMnO4 and Fenton treated + KMnO4 pine cone powder materials. vi | P a g e The second order derivative spectroscopy (SODS) was a suitable method for the analysis of the study of cationic dyes in binary solution. To determine the unknown concentrations of methyl violet and methylene blue dyes in binary solution using SODS, maximum wavelengths 561.8 nm and 623.1 nm were obtained. It was found that the percentage removal was higher for acrylic acid grafted pine cone than Fenton‘s treated and raw pine cone and treated samples adsorbed more methyl violet that methylene blue.
293

Efeito do artefato de \"beam hardening\" na capacidade de identificação das alterações periodontais e peri-implantares / \"Beam Hardening\" artefact effect in identifying capacity of periodontal and peri-implant changes

Noro Filho, Gilberto Araújo 09 December 2015 (has links)
Artefatos ocorrem principalmente, próximos de estruturas de alta densidade como o metal, sendo que essa alteração pode interferir na interpretação das imagens e no diagnóstico. O intuito do presente estudo é avaliar o nível ósseo ao redor de dentes e implantes por meio de dois programas diferentes e a qualidade da imagem na presença de artefatos metálicos. Foram avaliadas imagens de arquivo obtidas através do TCFC Gendex(TM) GXCB500 (Gendex Dental Systems, Des Plaines, IL, USA). Os software utilizados foram o Xelis Dental (InfinnitHealthcare, South Korea) e o OsiriX MD (Pixmeo, Geneva, Switzerland) em cortes tomográficos transaxiais de 2 mm. Foram avaliadas 145 imagens de TCFC, sendo incluídos no estudo 35 exames (as idades variaram de 35 a 83 anos), representando um total de 30 Dentes e 30 Implantes, sendo que houve uma distribuição harmônica entre os grupos em relação ao gênero e idade. Três avaliadores treinados realizaram as observações das imagens separadamente em dois períodos distintos e a qualidade da imagem foi classificada em severa, forte, moderada e mínima. Na avaliação da qualidade de imagem os implantes apresentaram uma prevalência maior de artefatos severo e forte. No entanto, as avaliações dos implantes apresentaram uma maior consistência intra-observador, demonstrando, portanto, uma maior dificuldade na classificação dos dentes. Além disso, na avaliação conjunta de dentes e implantes a consistência global dos observadores aumentou. O software OsiriX apresentou desempenho superior nas medidas lineares dos dentes e implantes na avaliação intra-examinador. Embora nenhuma das correlações intraclasse avaliadas tenha sido excelente, a grande maioria foi satisfatória, com valores entre 0,4 e 0,7. Podemos concluir que a presença de artefatos metálicos limita a qualidade da imagem do nível ósseo ao redor dos dentes e implantes, assim como o programa OsiriX apresentou resultados nitidamente superiores na avaliação das medidas lineares. / Artifacts occur mainly near high-density structures, such as metal, this alteration may affect images interpretation and diagnosis. The aim of this study is to evaluate the bone level around teeth and implants through two different software and image quality in presence of metal artefacts. Archival images obtained were evaluated by CBCT Gendex(TM)GXCB500 (Gendex Dental Systems, Des Plaines, IL, USA). The software used was Xelis Dental (InfinnitHealthcare, South Korea) and OsiriX MD (Pixmeo, Geneva, Switzerland) in transaxial tomographic slices of 2 mm. We evaluated 145 CBCT images and included in the study 35 exams (ages ranged from 35 to 83 years-old), representing a total of 30 teeth and 30 implants, there was a harmonic distribution between groups in relation gender and age. Three trained examiners made observations of images separately in two distinct periods and the image quality evaluation was classified in severe, strong, moderate and minimal. Evaluation of implants image quality presented a higher prevalence of severe and strong artifacts. However, implants evaluation presented a higher intra-observer consistency, therefore teeth assessment presents a greater difficulty. In addition, joint assessment of teeth and implants increased global consistency of observers. OsiriX software outperformed intra-examiner linear measurements of teeth and implants. Although none of the intraclass correlations evaluated has been excellent, vast majority was satisfactory, with values between 0.4 and 0.7. We conclude that presence of metal artifacts limits the image quality of bone level around teeth and implants as well as software OsiriX presented significantly better results in the evaluation of linear measurements.
294

Avaliação da morfologia craniofaciall de indivíduos com deformidades dentofaciais de classe III por meio de tomografias computadorizadas de feixe cônico / Evaluation of the craniofacial morphology of subjects with dentofacial Class III deformities using cone beam computed tomography

Miasiro Junior, Hiroshi 03 April 2009 (has links)
A deformidade dentofacial de Classe III está associada a importantes alterações funcionais, psicológicas e estéticas. O objetivo neste trabalho foi avaliar a morfologia craniofacial de indivíduos adultos, com deformidades dentofaciais de Classe III comparando-os com um grupo de indivíduos com faces equilibradas com finalidade de diagnóstico e prognóstico ortodôntico e cirúrgico. Foram avaliados 50 indivíduos, os quais foram submetidos ao exame de tomografia computadorizada de feixe cônico (i- Cat®/ Cone beam 3-D Dental Imaging System, Imaging Sciences International, Hatfield, USA) com o propósito de avaliação e diagnóstico. A amostra foi dividida em dois grupos, sendo 25 indivíduos com equilíbrio das relações faciais e oclusão dentária excelente e 25 com maloclusão Classe III sendo que estes fazem parte da clínica de preparo ortodôntico para Cirurgia Ortognática da Faculdade de Odontologia da FOUSP. Após a obtenção dos arquivos digitais foram realizadas as reconstruções das imagens em três dimensões nos softwares Dolphin 3D® (Dolphin Imaging and Management Solutions, Chatsworth, CA EUA) e Maxilim® (Medicim- Medical Image Computing, Mechelen-Bélgica). Seqüencialmente foram demarcados pontos de referência anatômica e a seguir foram mensuradas grandezas lineares angulares e proporcionais que foram representadas, após avaliação estatística, por média e desvio padrão. Para determinação do erro do método foram calculadas as correlações intraclasses para avaliação da concordância e a fórmula de Dahlberg. Para comparação entre os grupos foi aplicada a Análise de Variância (ANOVA) com dois fatores, destinada a representar a oclusão e gênero. No caso de ocorrência de interação estatisticamente significativa foram realizadas comparações múltiplas de Tukey para verificar em qual dos gêneros dentro de cada grupo ocorreu diferença. O nível de significância adotado foi o de 5%. Com relação ao erro do método foi observada alta reprodutibilidade na avaliação intraoperador nos softwares Dolphin 3D® e Maxilim®. Na comparação cefalométrica 3D entre os grupos avaliados, foram observadas diferenças significativas (p<0,05), sendo que o grupo com deformidades dentofaciais Classe III demonstrou variações para o relacionamento entre altura e largura facial, associada ao aumento da porção inferior da face; rotação horária da mandíbula relacionada à maior inclinação do corpo e do ramo mandibular e pelo predomínio da altura facial anterior em relação à posterior; diminuição do comprimento e do ângulo da base craniana; compensação na altura alveolar da maxila; predominância da dimensão mandibular na configuração ânteroposterior do esqueleto facial e tendências compensatórias verticais que reduziram ao nível alveolar, os desequilíbrios esqueléticos estruturais. / Class III dentofacial deformity is associated with important functional, psychologic and aesthetics changes. The objective of this study was to evaluate the craniofacial morphology of adults, with Class III dentofacial deformity comparing them with a group of subjects with harmonious faces for diagnosis and prognosis in orthodontic and surgical cases. This study evaluated 50 subjects that were submitted to the cone beam computed tomography (i-Cat®/ Cone beam 3-D Dental Imaging System, Imaging Sciences International, Hatfield, USA) with the purpose of diagnosis. The sample was divided in two groups, one with 25 subjects with harmonious faces and excellent occlusion and another with 25 subjects with Class III malocclusion, that are in treatment in the orthodontic clinic for orthognathic surgery in the Faculty of Dentistry of University of São Paulo. After the digital archives were obtained, the 3D reconstruction of images were performed with the softwares Dolphin 3D® (Dolphin Imaging and Management Solutions, Chatsworth, CA EUA) and Maxilim® (Medicim- Medical Image Computing, Mechelen-Bélgica). After demarcation of the reference points, linear, angular and proportional measurements were made and represented in statistical analysis, by mean and standard deviation. To determine the error of method, intraclass correlations were calculated, and Dahlbergs formula was used. To compare both groups the Variance Analyses was applied (ANOVA) with two factors, representing occlusion and gender. When statistical significant differences were observed, Tukeys multiple comparison was performed to evaluate in which gender the variance happened. The level of significance adopted was 5%. The error of method showed high reproducibility for intra-operator evaluation in Dolphin 3D® and Maxilim® softwares. Cephalometric 3D evaluation of the groups, showed significant differences (p<0,05), and the group with Class III dentofacial deformity showed changes in the relationship of height and width, associated with an augmented height of the lower face; clock-wise rotation of the mandible related to an increase of the inclination of the mandible body and ramus and a greater anterior facial height in relation to the posterior facial height; decrease in the size and angulation of the cranial base; compensation in height of dentoalveolar maxilla; predominant mandibular size in anterior-posterior configuration of the facial skull and vertical dentoalveolar compensations that reduced to alveolar level the structural skeletal unbalance.
295

Estudo de calcificações em tecidos moles em exames de tomografia computadorizada de feixe cônico e radiografia panorâmica digital / Differentiating soft tissue calcifications in CBCT and panoramic images

Centurion, Bruna Stuchi 29 April 2011 (has links)
A maioria das calcificações em tecidos moles na região de cabeça e pescoço são achados radiográficos incidentais. Com o crescente uso da Tomografia Computadorizada de Feixe Cônico na Odontologia (TCFC) há um aumento do número desses achados, visto que o exame permite a visualização das estruturas em três dimensões. Esse estudo estabeleceu uma metodologia para identificar algumas dessas calcificações. Um observador calibrado analisou 100 exames de TCFC e as respectivas panorâmicas, quanto à presença de Ossificação do Complexo Estilo-Hióideo (OCEH), tonsilólitos e ateromas. Adicionalmente os processos estilóides foram mensurados. As correlações para as radiografias panorâmicas foram estatisticamente significante entre idade e comprimento do processo estilóide. As correlações para os exames de TCFC foram estatisticamente significantes entre idade e tonsilólitos, idade e o comprimento do processo estilóide e idade e ateromas. Houve diferença estatística significante (Wilcoxon p<0,05) entre os exames de TCFC e panorâmicas quanto à presença de tonsilólitos, presença de OCEH e para as mensurações dos processos estilóides. Foi detectada maior quantidade de calcificações em tecidos moles nos exames de TCFC. A identificação das calcificações em tecidos moles é importante no diagnóstico diferencial de muitas patologias incluindo os flebólitos. Portanto o profissional deve ficar atento a correta interpretação dessas estruturas, buscando evitar erros e omissões, para que possa oferecer ao paciente opção correta de tratamento se for necessário. / The most common soft tissue calcifications in head and neck region are incidental findings in radiographic images. The use of Cone Beam Computed Tomography in Dentistry, has increased these incidental findings mainly, because CBCT allows a third dimension view. The goal of this study was to differentiate the styloid chain ossification (SHCO), tonsilloliths and calcified atheromas. Based on a specific methodology, one calibrated observer analysed 100 panoramic and CBCT exams from the same patients regarding these alterations. Afterwards, the styloid process was measured at the same exams. The correlations tests for the panoramic exams were statistically significant between age and styloid process length. The correlations tests for CBCT exams were statistically significant between age and tonsilloliths, age and styloid process length and age and calcified atheromas. There was a difference statistically significant (Wilcoxon p<0.05) between CBCT and panoramic exams regarding: presence of tonsillolith, presence of SHCO and styloid process length. It was detected more quantity of soft tissues calcifications in CBCT exams. The identification of soft tissues calcifications is important for the differential diagnoses of many pathologies including phlebolits. Therefore the professional should be able to do a correct image interpretation in some cases in order to avoid mistakes and offer the patient a treatment if is necessary.
296

Precisão e acurácia de medidas lineares da mandíbula em imagens 3D obtidas por meio da tomografia computadorizada de feixe cônico / Accuracy and reliability of mandibular linear measurements on 3D CBCT images with different voxel sizes

Fernandes, Thais Maria Freire 29 September 2011 (has links)
Objetivo: Avaliar a precisão e a acurácia de medidas lineares da mandíbula por meio da Tomografia Computadorizada de Feixe Cônico (TCFC), alterando o valor do voxel. Material e Métodos: Dez mandíbulas foram submetidas à TCFC seguindo dois protocolos de voxel, 0,2 e 0,4 mm, do aparelho i-CAT Classic. Dez medidas lineares foram realizadas 2 vezes, por 2 examinadores independentes, previamente calibrados, nos cortes multiplanares e nas reformatações 3D no programa Dolphin®. As medidas físicas foram realizadas com um paquímetro digital diretamente nas mandíbulas. Análise de variância para medidas repetidas (ANOVA), coeficiente de correlação intraclasse e o teste de Bland-Altman foram utilizados para avaliar a precisão e a acurácia (p<0,05). Resultados: Excelente precisão intra e boa precisão interexaminadores foi encontrada para todas as variáveis, com exceção da largura interforame mentual entre os dois examinadores nas reformatação 3D. As mensurações realizadas nos cortes multiplanares apresentaram maior acurácia que as mensurações nas reformatações 3D, em relação às medidas físicas. Conclusão: As imagens nos cortes multiplanares em TCFC nos dois protocolos de voxel podem ser utilizadas com precisão e acurácia para a obtenção de medidas lineares quando comparadas com às medidas físicas. Maior cautela deve ser tomada para as reformatações 3D, pois as mensurações neste formato foram precisas, mas não acuradas para todas as variáveis. Um protocolo com menor exposição aos raios X, sem comprometer o diagnóstico, torna-se viável, pois o aumento na resolução das imagens não aumenta a precisão e acurácia na mensuração das medidas lineares avaliadas. / Objective: The purpose of this study was to determine the accuracy and reliability of mandibular linear measurements obtained from 3-dimensional cone-beam computed tomography (CBCT) scans of dry human mandibles using different voxel sizes. Methods: Ten dry human mandibles were scanned at voxel sizes of 0.2 and 0.4 mm. Craniometric anatomical landmarks were identified on the multiplanar reconstructed and on volume rendering images that were generated by the software Dolphin®, independently, by two operators twice. Subsequently, physical measurements were made using a digital caliper. Analysis of variance for repeated measures (ANOVA), Intraclass correlation (ICC) and BlandAltman were used for evaluating accuracy and reliability(p<0.05). Results: Excellent intrarater and good interobserver reliability values were found for linear measurements from CBCT images, with only one exception, interforame width, between observers in volume rendering images. Measurements performed on multiplanar reconstructed images were more accurate than the measurements in volume rendering compared to the gold standard. Conclusion: Linear measurements on multiplanar images of 0.2 and 0.4-voxel are reliable and accurate when compared with direct caliper measurements. Caution should be taken in the volume rendering measurements, because the measurements were reliable, but not accurate for all variables. A protocol with less exposure, without compromising the diagnosis becomes feasible, because an increased voxel resolution did not result in greater accuracy of the measurements and potentially provides increased patient radiation exposure.
297

Estudo dos parâmetros de estabilidade de travamento entre implante dentário e componente protético através do sistema cone Morse / Study on the stability parameters of locking between dental implants and prosthetic component system through the Morse taper

Aranha, Luís Cláudio 05 December 2014 (has links)
Na implantodontia visa-se dois grandes resultados para os desdentados parciais e totais, função mastigatória e estética. Ambos têm o mesmo grau de importância, para tanto se deve pensar no que se tem de mais seguro e prático nos dias de hoje. O cone Morse, na implantodontia oral, é um sistema de estabilidade entre o implante dentário e o parafuso intraósseo de sustentação. Para seu correto uso se faz necessário uma série de análise de suas características e condições. No presente trabalho focou-se em desenvolver protocolo de validação de torque, além de analisar parâmetros de acabamento, deformação e estabilidade précarga e pós-carga dentro de protocolos já recomendados. Avaliou-se sua condição antes e após os efeitos de carga mastigatória simulada por ensaio de fadiga. Concluiu-se que o uso do cone Morse dentro dos protocolos indicados deve ser revisto quanto a padrões similares de torque nos pilares sólidos e indexados, cada um possui limites e indicações diferentes para se manter estável. Concluiu-se também que não é um sistema totalmente livre de trânsito de bactérias e que esse trânsito aumenta de forma proporcional ao uso e força mastigatória, indicando que melhorias no acabamento entre as peças devem ser implementadas e/ou adição de material que afaste crescimento bacteriano priorizando a saúde do periodonto e do tecido ósseo de sustentação mantendo o sistema seguro em longevidade. / In implantology it is aimed two major outcomes for the partial and total toothless persons, mastigatory function and aesthetics. Both have the same degree of importance, therefore it must be thought about what is safer and more practical these days. Morse taper in oral implantology is a system of stability between the dental implant and the intraosseous screw support. For its correct use a series of analysis of its features and conditions is required. This work was focused on developing torque validation protocol, and analyzing surface finishing parameters, deformation and stability as before load and after load in recommended protocols. The implants condition before and after the effects of habitual masticatory load was simulated by fatigue testing. It was concluded that the Morse taper use within the specified protocols should be reviewed for similar patterns of torque in solids and indexed pillars, each has different limits and signs to remain stable. It was also concluded that it is not a traffic totally free system of bacteria and that this influence increases in proportion to the use and masticatory forces, improvements in the surface finish between parts and / or addition of material that hinders bacterial growth is needed if it is prioritized the health of the periodontium and the bone tissue keeping the system safe in the long therm.
298

Análise quantitativa de modelos de prototipagem rápida baseados em dados de tomografia volumétrica, por meio de inspeção de engenharia reversa tridimensional / Quantitative analysis of rapid prototyping models based on datas of cone beam computerized tomography by inspection of three-dimensional reverse engineering

Kang, Fatima Maria de Angelis 18 September 2009 (has links)
O objetivo neste estudo foi avaliar a reprodutibilidade quantitativa dos modelos tridimensionais gerados por meio de imagens de tomografia volumétrica de feixe cônico, obtidos por dois tomógrafos volumétricos NEWTOM 9000 DVT (i- (Quantitative Radiology, Verona, Itália) e i-CAT (Imaging Sciencies Int. Hatfield, Pensilvânia. Estados Unidos da América), submetidos à inspeção de engenharia reversa. Uma mandíbula macerada foi digitalizada por meio do SCANNER 3D VIVID 910, com precisão de 0,01 mm, associado à fotometria digital, sendo utilizado o software GEOMAGIC STUDIO, e assim obteve-se um modelo considerado padrão ouro. Posteriormente realizamos o exame de tomografia volumétrica de feixe cônico, na mesma mandíbula nos dois tomógrafos volumétricos, obtendo-se assim os modelos virtuais tridimensionais. Por meio de um alinhamento das geometrias do padrão ouro com os modelos virtuais resultantes da tomografia do aparelho NEWTOM 9000 DVT e do i-CAT, foram observadas as possíveis discrepâncias. Concluímos que estas alterações encontradas após a análise quantitativa das diversas regiões foram menores nas imagens adquiridas pelo tomógrafo volumétrico de feixe cônico modelo i-CAT, e portanto possibilitam a geração de modelos de prototipagem rápida de melhor qualidade. / The purpose of this study was to evaluate the quantitative reproductability of the 3d models created using CT images. The images used were obtained from two different cone beam tomographs: NEWTOM 9000 DVT (Quantitative Radiology, Verona, Italy) and i-CAT ( Imaging Sciences Int., Hatfield, EUA) and then inspected through reverse engineering processing software. A dry mandible was digitalized using a 3D Scanner VIVID 910 and the GEOMAGIC STUDIO software to obtain a 0,01mm precision model considered to be our gold standard. Two distinct 3D virtual models were then created after submitting the same dry mandible to a cone beam exam on both tomographs (NEWTOM and i-Cat). Possible discrepancies between the 3D models and the gold standard were analyzed through and alignment of their geometries. After evaluating the discrepancies at the different sites of the models, we concluded that the virtual model obtained using the i-Cat tomograph images was more accurate and therefore of greater quality.
299

Estudo de calcificações em tecidos moles em exames de tomografia computadorizada de feixe cônico utilizando diferentes softwares

Pagin, Bruna Stuchi Centurion 22 June 2015 (has links)
O uso crescente da Tomografia Computadorizada de Feixe Cônico (TCFC) na área odontológica tem permitido o aumento dos achados incidentais em exames que são realizados por outros fins. Dentre essas uma, das mais comuns e com impacto na vida dos pacientes é o ateroma calcificado das artérias carótidas (ACAC), e no seu diagnóstico diferencial existem as ossificações das cartilagens da laringe. Para correta identificação dessas calcificações são necessários conhecimentos acerca da localização anatômica, distribuição e sua morfologia, sendo que a TCFC fornece uma localização tridimensional (3D) acurada. Entretanto existem diferentes softwares de pós-processamento de imagens disponíveis no mercado, e não há na literatura estudos sobre a capacidade desses softwares para a visualização dessas estruturas. Esse estudo tem o objetivo de identificar essas calcificações supracitadas, nos softwares de visualização de TCFC, i-Cat Vision® e Invivo5®, nas reconstruções multiplanares e 3D em dois grupos diferentes, sendo um grupo de exames de indivíduos com fissuras labiopalatinas (HRAC) (50 exames de TCFC) e outro sem fissuras labiopalatinas (FOB) (100 exames de TCFC). Foram avaliados 150 exames (112 do gênero feminino e 38 do gênero masculino) de TCFC por dois observadores devidamente treinados e calibrados. Para o grupo sem fissuras labiopalatinas foi encontrada diferença estatística significante entre a idade e a quantidade de calcificações encontradas. Considerando todas as calcificações, foram encontrados 104 indivíduos com alguma calcificação, representando 69,33% da amostra, sendo que o grupo HRAC apresentou 88% e o grupo FOB 59%. Foi possível demonstrar diferença estatística significante ao se comparar a quantidade de calcificações entre os grupos avaliados. Foi assumido nesse trabalho que as reconstruções separadamente do programa Invivo5® seria a padrão- ouro, nesse momento o programa i-Cat Vision® foi considerado mais específico do que sensível. Foram identificados muito falsos positivos no programa i-Cat Vision® e menores resultados para falso-negativos. Esse trabalho não tem o propósito de identificar os ACAC nos exames de TCFC, mas incentivar e demonstrar que é possível visualizar tais calcificações e diferenciá-las umas das outra, lembrando-se da responsabilidade do dentista em prevenir um problema futuro ao paciente que pode levar a quadros de morbidade e mortalidade. / The widespread use of CBCT in Dentistry leads to an increasing of incidental findings regarding exams for different purposes. The most common incidental finding that impacts the patients quality of life is the carotid artery calcifications as well as the ossification of laryngeal cartilage which is the most common differential diagnosis for aterosclerosis. To identify this calcifications/ossification correctly it is necessary to know about its anatomic localization, distribution and morphology once that CBCT images may evidence an accurate 3D location. Therefore many different manipulations imaging software for CBCT technology is available and there is no research in the literature about the capacity of this software to visualize these calcification/ossification structures. This study aimed to identify these calcifications/ossification, in two different visualization softwares: i-Cat Vision® and Invivo5®, both in Multiplanar Reconstruction (MPR) and 3D reconstruction, in two different groups, where one was constituted of cleft lip and palate (50 CBCT exams) patients and the other by patients without cleft lip and palate (100 CBCT exams). Two calibrated and trained observers evaluated 150 CBCT exams (112 were female and 38 male). There was significantly statistical difference when comparing age and calcifications quantity for no cleft lip and palate group. When considering all calcifications in both groups, 104 patients in 150 (total number) showed some calcification/ossification, representing 69,33%. The percentage of calcification/ossification in the cleft lip and palate group were 88% whereas the other one evidenced 59%. And due to this difference, there was significantly statistical difference between these groups. Besides, the Invivo5® software was considered the gold-standard (multiplanar reconstruction and 3D reconstruction) to identify the structures previously mentioned; then i-Cat Vision® software showed more specificity than sensitivity comparing the results with the Invivo5®. Many false positives were identified in i-Cat Vision® and only some false negatives, showing again the characteristics of these softwares. This work was not intended to identify carotid artery calcifications in CBCT exams, but in fact the real purpose was to demonstrate that it is possible to identify calcifications/ossifications and differentiate one of another. It is always important to remember about the dentistry knowledge and responsibility to prevent patient coming disease that may lead to morbidity and mortality situations.
300

Avaliação da precisão da tomografia computadorizada por feixe cônico (cone beam) como método de medição do volume ósseo vestibular em implantes dentários / Evaluation of the accuracy of computed tomography cone-beam (cone beam) as a method of measuring buccal bone volume in dental implants

Shiratori, Lucy Naomi 07 December 2009 (has links)
A monitoração radiográfica das mudanças no nível ósseo fornece sinais valiosos para assegurarmos a longevidade e estética dos implantes. As radiografias periapicais e panorâmicas são importantes instrumentos que permitem esta avaliação, mas tem limitações, pois fornecem imagem bidimensional. As imagens tomográficas fornecem detalhes para estimar dimensões verticais e horizontais, possibilitam a melhor visualização de defeitos ósseos e estruturas anatômicas para o planejamento cirúrgico, além de permitir a monitoração radiográfica pós-cirúrgica ao redor dos implantes. O propósito deste trabalho foi avaliar a precisão da tomografia computadorizada por feixe cônico (TCCB) na medição do volume ósseo vestibular ao redor de implantes. Foram utilizados 8 crânios secos que receberam de 3 a 6 implantes na região da maxila anterior dependendo da disponibilidade óssea, em seguida foi realizada uma TCCB. Por meio dos cortes das imagens, as medições da parede óssea em 3 pontos do implante foram obtidas, analisadas e comparadas às realizadas no modelo do crânio em gesso, que continha implantes da mesma altura e diâmetro, nos mesmos pontos determinados, ou seja, no ápice do implante (A), a 5 mm do ápice (B) e do primeiro contato osso/implante até a plataforma do implante (C). O resultado do estudo mostrou que para os 3 pontos (A, B, C) não houve diferença estatisticamente significante das medidas realizadas no modelo real com a tomografia, ou seja, a TCCB pode ser um instrumento útil para se avaliar longitudinalmente o volume ósseo vestibular, porém, mais estudos clínicos se fazem necessários para ser utilizado na clínica diária. / Monitoring radiographic changes in bone level provides valuable signals to insure the longevity and aesthetics of implants. The panoramic and intra-oral radiographs are important devices for this assessment, but have limitations, they provide twodimensional images. The computed tomographics images provide details to estimate vertical and horizontal dimensions, allow for better visualization of bone defects and anatomical structures important in surgical planning, avoiding anatomical regions that could result in surgical injuries, and allows radiographic monitoring after surgery around implants , a factor of great importance for aesthetics and longevity of implants. The purpose of this study was to evaluate the accuracy of cone beam computed tomography (TCCB) in measuring the buccal bone volume around these implants. 8 skulls were used to install 3 to 6 implants in the anterior maxilla (canine to canine) depending on the availability of bone. These implants were installed in the skull, and then held a TCCB. Through the courts of the images, measurements of the bone wall at 3 points of the implant were obtained, analyzed and compared to those obtained in the model of the skull in plaster. Implants with the same height and diameter were used in the model and the same points determined, ie, the apex of the implant (A), 5 mm from the apex (B) and the first contact implant-bone to the plataform of the implant, were measured. (C).The results showed that for the 3 points (A, B, C) of the implants, no statistically significant difference in measurements obtained from the plaster model and computed tomographics images. Considering the results, TCCB can be a useful tool for assessing buccal bone volume along the implant, however, further studies are needed to be used in clinical practice.

Page generated in 0.0354 seconds