• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 986
  • 14
  • 14
  • 12
  • 12
  • 12
  • 7
  • 5
  • 2
  • 1
  • Tagged with
  • 1010
  • 561
  • 526
  • 363
  • 197
  • 181
  • 148
  • 127
  • 117
  • 108
  • 104
  • 103
  • 89
  • 86
  • 84
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Estratégias visando eficiência energética e conforto térmico incorporados aos projetos de edificações residenciais em Maringá-PR

Cardoso, José Carlos Mendes January 2002 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Civil. / Made available in DSpace on 2012-10-19T16:08:52Z (GMT). No. of bitstreams: 1 194335.pdf: 2415326 bytes, checksum: 4193e02c500031209c72fa9927fc0b33 (MD5) / A crise do petróleo em 1973 e a crise de energia como um todo que ultimamente vem emergindo no Brasil e até em paises como os Estados Unidos, fazem repensar como são concebidos e executados, há vários anos, os edifícios em nosso país. Onde encontramos edificações negligentes quanto à eficiência energética e conforto ambiental. E isso evidencia-se cada vez mais com a crescente conscientização, principalmente nos paises mais desenvolvidos, quanto à conservação dos recursos naturais. Questiona-se o papel da arquitetura na execução de edificações mais bem resolvidas energeticamente, mas com a manutenção de índices satisfatórios de conforto. O intuito desta pesquisa é verificar através de questionários e levantamentos, se os princípios mais simples e recomendados de estratégias de projeto arquitetônico em edificações, visando eficiência energética e conforto ambiental, são incorporados às habitações. E verificar como os profissionais desses projetos atuam, na cidade de Maringá, ante aos temas e qual a interferência dos usuários/contratantes desses projetos nesse contexto. Além de verificar como esse usuário avalia seu imóvel. Tendo como pano de fundo a tipologia construtiva predominante na cidade de Maringá: edificações residenciais unifamiliares acima de 140m². Foram feitos estudos de casos e aplicados questionários aos profissionais que desenvolvem projetos na área e aos contratantes dos mesmos, buscando verificar como se dá em Maringá a questão projeto arquitetônico versus eficiência e conforto nas edificações pesquisadas. Discute-se ainda as razões pelas quais são pouco incorporados em projetos arquitetônicos, os temas abordados. Os resultados apontam que essa deficiência se dá por falta de interesse nas questões citadas e por formação profissional inadequada, e ainda por falta de conscientização dos envolvidos.
82

Condições de conforto térmico para estudantes de 2o. grau na região de Florianópolis /

Xavier, Antonio Augusto de Paula January 1999 (has links)
Dissertação (Mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. / Made available in DSpace on 2012-10-18T18:13:28Z (GMT). No. of bitstreams: 0Bitstream added on 2016-01-09T01:24:19Z : No. of bitstreams: 1 150602.pdf: 48918332 bytes, checksum: 17b48b8fe0e72b59213a3b6c2331e0b6 (MD5)
83

Uso do sistema de fachadas duplas ventiladas em edifícios de Curitiba

Mazzarotto, Ana Carolina Elizabeth Kolb 02 April 2012 (has links)
Resumo: A partir dos anos 1990, uma tipologia de fachada, caracterizada pela exploração da transparência do vidro na arquitetura, passou a ser intensamente utilizada na Europa, como uma estratégia de arquitetura mais sustentável. Denominado de fachada dupla ventilada, este sistema compõe-se por pelo menos duas peles, geralmente envidraçadas, posicionadas entre o espaço interno ocupável e o ambiente externo, configurando um canal para ovimentação do ar. Este aspecto, a passagem intencional e controlada do ar nesta cavidade, diferencia a tecnologia das fachadas com vidro duplo ou triplo. A tecnologia baseia-se na noção de fechamentos externos com a característica de responder dinamicamente à variação das condições ambientais do local de um edifício, incorporando elementos de sombreamento integrados, ventilação natural e estratégias de isolamento térmico. As fachadas duplas ventiladas apresentam um comportamento distinto das fachadas convencionais, devido à complexidade dos processos físicos envolvidos que afetam o desempenho do edifício como um todo. Como este sistema é fortemente dependente das condições externas (como a radiação solar e temperatura externa), já que estas influenciam o clima interno, deve ser projetado considerando as particularidades de seu contexto e orientação da fachada. Para atingir objetivos como eficiência energética e conforto ambiental, seu projeto deve ser alvo de intenso planejamento e simulações para prever seu desempenho e otimizar o sistema. O objetivo desta pesquisa é analisar o desempenho térmico e energético de edifícios de escritórios com fachadas duplas ventiladas, em condição de clima subtropical, esclarecendo a sua sensibilidade em relação a variáveis de desempenho. A estratégia utilizada é experimental (simulação) e a delimitação geográfica, Curitiba. A revisão bibliográfica, prévia ao desenvolvimento do estudo, pretende fornecer subsídios para a realização das simulações, abordando os conceitos do sistema de fachadas duplas, seu comportamento físico, parâmetros de projeto e procedimentos de modelagem e simulação. A simulação apresenta resultados do regime de temperaturas internas nos ambientes, de consumo de energia para condicionamento artificial, dos processos de transferência de calor e do comportamento da ventilação natural, decorrentes do tratamento dos edifícios com osistema de fachadas duplas ventiladas. Os modelos simulados foram denominados de A e B, e cada um foi modelado no programa de simulação com a configuração de fachada convencional ou simples (modelo base de referência para comparações) e com a adição da fachada dupla ventilada (modelo proposto). O modelo A é conceitual, e representa uma unidade de escritório de um edifício comercial de Curitiba, configurado a partir de pesquisa junto ao mercado imobiliário. Já o modelo B representa um edifício real, selecionado para aplicação da estratégia de retrofitting de fachada. Os resultados obtidos confirmam a hipótese do trabalho quanto ao potencial do sistema de fachada dupla ventilada, aplicada aos casos selecionados, para a melhora do desempenho térmico e energético de seus ambientes de trabalho.
84

Análise do desempenho termoenergético de um prédio histórico de elevada inércia térmica / Thermoenergetic performance analysis of a high thermal mass historic building

Carotenuto, Adriano Roberto da Silva January 2009 (has links)
O trabalho tem com objetivo avaliar o desempenho termoenergético de um prédio histórico de elevada inércia térmica da Universidade Federal do Rio Grande do Sul: Instituto de Química, fundado em 08 de junho de 1926, localizado no Campus Central da Universidade, em Porto Alegre. O estudo desenvolvido neste trabalho faz parte do projeto de recuperação do patrimônio histórico e cultural da UFRGS, no qual o prédio do Instituto de Química será a sede do Centro Cultural da Universidade. A ferramenta utilizada para a avaliação do desempenho termoenergético do prédio é o programa EnergyPlus, versão 2.2. A simulação do prédio é realizada com os 14 dias de projeto definidos pela ASRHAE [2001a] e com o arquivo climático anual da cidade de Porto Alegre. Os ambientes da edificação foram declarados no programa por meio de 69 zonas térmicas, cada qual composta por todas as superfícies de transferência de calor, incluindo, também, portas e janelas em detalhes. No total, são 39 zonas térmicas atendidas pelo sistema de ar-condicionado, sendo que as outras 30 zonas térmicas são deixadas em evolução livre da temperatura para avaliação do comportamento térmico dos ambientes sem climatização. O sistema de ar-condicionado utilizado na simulação é o VRV (Vazão de Refrigerante Variável). O sistema de ar-condicionado simulado leva em consideração as correlações de desempenho de cada unidade externa e os dados de desempenho das unidades internas selecionadas. Os resultados das máximas potências de refrigeração obtidos na simulação estão abaixo das potências de refrigeração das unidades internas e externas, as quais mantêm a temperatura média do ar da zona na temperatura do ponto de ajuste do termostato. São avaliadas também as variáveis representativas do conforto térmico das zonas simuladas, tais como, temperatura média do ar, temperatura média radiante, temperatura operativa, umidade relativa e PMV ao longo dos meses do ano, cujos limites estão definidos nas zonas de conforto térmico pela ASHRAE [2004a]. O trabalho mostra que o controle do termostato pela temperatura do ar da zona simulada com ar-condicionado nem sempre atende aos limites das zonas de conforto térmico, no entanto, os parâmetros de conforto térmico da maioria das zonas térmicas analisadas com ar-condicionado estão dentro dos limites dos parâmetros da zona de conforto térmico do verão. No final, são apresentados o consumo e o custo de energia elétrica anual do prédio com o sistema de ar-condicionado de Vazão de Refrigerante Variável. É constatado que os equipamentos, nos quais estão incluídos os computadores, são os que mais consomem energia elétrica no prédio, seguido da iluminação e do sistema de ar-condicionado. / The present work analyses the thermoenergetic performance of a high thermal mass historic building. This building makes part of Rio Grande do Sul Federal University (UFRGS) historic buildings restoration program. It was inaugurated on june 8th of 1926 as a Chemical Industrial Institute and it is located in the main University Campus, in Porto Alegre city, Rio Grande do Sul State, Brazil. The study developed in this work makes part of the restoration program, in which the building will be a University Cultural Center. The software used to analyse the building thermoenergetic performance is EnergyPlus, version 2.2. The simulation is performed with fourteen design days and with Porto Alegre weather data. The building model is formed by 69 thermal zones, each one with all heat transfer surfaces, including, also, doors and windows in details. In the total, there are 39 conditioned thermal zones. The other 30 thermal zones are left without air-conditioning in order to analyse their thermal response regarding temperature evolution during the simulation. The air conditioned system used in the simulation is Variable Refrigerant Volume (VRV). The air-conditioned system in the simulation takes into account the performance curves of VRV outdoor units and performance data of indoor units selected. The maximum values of refrigeration capacity obtained in the simulation are under the indoor and outdoor units refrigeration capacity selected, and keep the zone mean air temperature in the thermostat set point. Also, it´s analyzed the thermal comfort parameters of simulated zones, as mean air temperature, mean radiant temperature, operative temperature, relative humidity and PMV during all the months of the year and in the design days, whose limits are defined in thermal comfort zones in ASHRAE [2004a]. The work concludes that the thermostat control by zone mean air temperature is not enough to keep the other thermal comfort parameters within thermal comfort zones envelope, meantime, for the most of zones analysed with air-conditioned, the thermal comfort parameters are within the limits of the summer thermal comfort zone envelope. In the end, it´s evaluated the monthly electrical power consumption and cost of the building with the air-conditioned VRV. It´s shown that equipment, in which it´s included the computers, is the greatest one in building electrical consumption, followed by lighting and cooling.
85

Avaliação energética visando certificação de prédio verde / Energetic assessment aiming at green building certification

Martinez, Maria Fernanda Baquerizo January 2009 (has links)
Nos últimos anos, as alterações na estrutura do setor elétrico e o aumento do valor das tarifas fizeram com que fossem desenvolvidos programas e projetos visando a conscientização do uso eficiente da energia elétrica. Programas com estas características também estão sendo implantados na construção civil para reduzir o consumo de energia, como é o caso das construções verdes e sustentáveis, conhecidas por green building. Para avaliar as construções foi criado pelo Conselho Norte-Americano de Construção Verde (United States Green Building Council - USGBC) o selo LEED™ (Leadership in Energy and Environmental Design). Este trabalho tem como objetivo avaliar por desempenho termoenergético um edifício residencial, mostrando meios de redução do consumo de energia elétrica com o sistema de condicionamento ambiental e ao mesmo tempo avaliar os níveis de conforto térmico dos usuários do edifício. O prédio escolhido para ser objeto deste estudo busca obter a certificação LEED™ do tipo Core and Shell. Este trabalho aborda o pré-requisito 2, Desempenho Mínimo no Uso da Energia, do aspecto Energy & Atmosphere. Além deste aspecto, é abordado também o crédito 7, Conforto Térmico, do Indoor Environmental Quality para avaliar os níveis de conforto térmico proporcionado aos usuários. Para verificar se a edificação em estudo está atendendo estes itens da certificação foi escolhida das três possíveis opções de análises fornecidas pela certificação a opção 1 - Simulação Energética Total da Edificação. O objetivo é demonstrar um aumento no desempenho da edificação proposta comparada com a edificação baseline definida conforme a ASHRAE [2007], usando o Building Performance Rating Method no Apêndice G da Standard. Para a realização da análise foram simulados dois edifícios, o baseline, que atende a norma ASHRAE [2007] e os propostos nos quais são simulados o prédio conforme o projeto arquitetônico e especificações do arquiteto e também são simuladas as alterações necessárias para que o prédio atenda as exigências do LEED™. Com base nos resultados obtidos com as simulações será analisado o consumo de energia elétrica para as cargas regulares estabelecidas no projeto do edifício e comparado com o edifício baseline. As análises de desempenho energético foram realizadas através de simulações computacionais, feitas com o auxílio do programa EnergyPlus, versão 3.1. As simulações da edificação são realizadas com quatro dias de projeto definidos pela ASHRAE [2005a] e com o arquivo climático anual de Porto Alegre. Os ambientes da edificação foram declarados no programa por meio de 129 zonas térmicas, sendo que todas elas são atendidas por sistema de ar-condicionado. O sistema de condicionamento ambiental utilizado é modelo mini-split de expansão direta e compressor rotativo, devido ao fato deste ter sido o tipo de sistema indicado no projeto elaborado para o prédio. No final são apresentados os resultados obtidos com as simulações realizadas possibilitando a verificação do comportamento energético de alguns dos parâmetros construtivos, como diferentes tipos de vidros, proteções internas e externas das esquadrias, proteções entre os vidros e revestimentos internos. A partir dos resultados obtidos, pode-se observar que o consumo energético do edifício foi reduzido significativamente além de existir uma melhorar o conforto térmico proporcionado aos ocupantes. Para o melhor caso apresentado neste trabalho a redução do consumo de energia elétrica total da edificação chegou a 11,58% quando comparado com o edifício baseline e as horas não confortáveis totais anuais para todos os ambientes analisados não ultrapassaram 300 horas. Com esses resultados o prédio em estudo atende o pré-requisito e o crédito avaliados da certificação LEED™. / Structural changes in the electric utilities sector and the increase in electricity rates in the last few years led to the development of programs and projects aimed at establishing a new awareness for the efficient use of electric power. Programs bearing such features have also been deployed in civil construction in order to reduce energy consumption, as in the case of green and sustainable constructions, better known as green building. The brand LEED™ (Leadership in Energy and Environmental Design) was created by the United States Green Building Council (USGBC) in order to evaluate whether such construction buildings were actually built and stand in environmentally correct operation. This research is aimed at assessing a residential building by using thermal-energetic performance, presenting means to reduce electric power consumption within the environment conditioning system and, at the same time, evaluate the levels of thermal comfort provided to the users of the building. The building chosen to be the object of this study is TRYing to obtain the Core and Shell type of the LEED™ certification. The approach of the present work comprises the pre-requisite 2, Minimum Performance in Power Use of the Energy & Atmosphere aspect. In addition, the credit 7, Thermal Comfort aspect of Indoor Environmental Quality is also included to evaluate the levels of thermal comfort granted to the users. In order to verify whether the building under study has met such certification items, the option 1 - Energetic Simulation of Total Building was chosen among the three possible analytical options supplied by the certification. The objective is to demonstrate an increase in the performance of the proposed building in comparison to the baseline building as defined by ASHRAE [2007], using the Building Performance Rating Method in Appendix G of Standard. Two buildings were simulated for the development of the analysis: the baseline building, where the ASHRAE [2007] standard is attained and the Proposed, where the building is simulated according to the architectural project and the specifications made by the architect, and the changes required for the building to fulfill the LEED™ requirements are also simulated. Therefore, based upon the simulations, the consumption of electric power for the regular charges established by the project regarding the building under study is going to be analyzed in comparison to the baseline building. The power performance analyses were accomplished through computer simulations carried out with the help of the EnergyPlus program, version 3.1. The building simulations were performed with four project days defined by ASHRAE [2005a] and the annual climatic file from the city of Porto Alegre, Brazil. The environments of the building were declared in the program by means of 129 thermal zones, all of which serviced by an air-conditioning system. The environmental conditioning system in use is the mini-split model with direct expansion and a rotating compressor owing to the fact that this type of system was indicated by the project designed for the building. The results obtained by each simulation were eventually presented, making it possible to verify that by changing of energetic behavior of a few building parameters, such as different types of glass, internal as well as external frame protections, protection in-between the glasses, and internal linings and coatings. From the results obtained, one is able to notice that the power consumption in the building was significantly reduced and improvements in the thermal comfort for the users were observed. For the best case presented in this work, the total reduction in power consumption in the building reached 11.58% when compared with the baseline building, and the total noncomfortable yearly hours for all the environments under analysis did not surpass 300 hours. As these results demonstrate, the building under study satisfies the pre-requisite and the credit as evaluated by the LEED™ certification.
86

Cenários futuros de mudanças climáticas e impactos do conforto térmico humano em áreas urbanizadas / Future scenarios of climate change and impacts of human thermal comfort in urbanized areas

Costa, Rafaela Lisboa 26 May 2017 (has links)
Tese (doutorado)—Universidade de Brasília, Instituto de Geociências, Pós-Graduação em Geociências Aplicadas, 2017. / Submitted by Raquel Almeida (raquel.df13@gmail.com) on 2017-08-10T17:33:07Z No. of bitstreams: 1 2017_RafaelaLisboaCosta.pdf: 17490961 bytes, checksum: 6048f42e68ba4ba3b51041e5ac2f25bc (MD5) / Approved for entry into archive by Raquel Viana (raquelviana@bce.unb.br) on 2017-09-20T16:32:38Z (GMT) No. of bitstreams: 1 2017_RafaelaLisboaCosta.pdf: 17490961 bytes, checksum: 6048f42e68ba4ba3b51041e5ac2f25bc (MD5) / Made available in DSpace on 2017-09-20T16:32:38Z (GMT). No. of bitstreams: 1 2017_RafaelaLisboaCosta.pdf: 17490961 bytes, checksum: 6048f42e68ba4ba3b51041e5ac2f25bc (MD5) Previous issue date: 2017-09-20 / O objetivo deste estudo foi avaliar os impactos das mudanças climáticas no grau de conforto e/ou desconforto térmico, sentido pela população de áreas urbanas da Região Nordeste do Brasil. Para a realização deste estudo, foram utilizados dados das 96 estações meteorológicas convencionais do Instituto Nacional de Meteorologia (INMET), distribuída por toda região de estudo. Inicialmente, procurou-se mostrar o comportamento das variáveis meteorológicas temperatura e precipitação, desde o ano de 1961 ao ano de 2014, por meio índices que avaliam tendências de ocorrência de extremos climáticos, Os impactos das mudanças climáticas foi investigado com base na média dos resultados de quatro modelos climáticos globais, ECHAM5-OM, HADGEM2-ES, BCM2 e o CNRMCM3, para dois cenários de emissões de gases de efeito estufa, A1B e A2 que tiveram suas projeções futuras regionalizadas para o período 2021-2080 com o emprego da técnica de downscaling estatístico. Para avaliar o conforto/desconforto térmico, utilizouse o Índice de Desconforto de Kawamura (IDK), onde foi possível fazer uma avaliação das consequências das mudanças climáticas, no grau de conforto/desconforto térmico na região Nordeste, por meio de uma análise futura para esse índice. Por fim, por meio do uso da técnica de sensoriamento remoto, tentou-se identificar ilhas de calor em áreas urbanas pré-selecionadas, assim como, avaliar se houve expansão da mancha urbana e o comportamento do conforto térmico humano nessas áreas. Os resultados encontrados permitiram concluir que: (i) Por meio do uso de índices que avaliam tendências de extremos, durante os anos de 1961 a 2014, houve uma diminuição significativas das chuvas em toda a região e, também, aumento das temperaturas, tanto máximas como mínimas; (ii) Poderá haver redução da precipitação nos respectivos períodos chuvosos das sub-regiões do Nordeste, aumento das temperaturas máximas no primeiro semestre e diminuição em extensas áreas do setor norte do Nordeste em meses do segundo semestre, principalmente para o cenário A2. Para as temperaturas mínimas os resultados apontam para tendência de aumento em todo o ano com destaque para os meses de inverno, em toda a região; (iii) As análises dos cenários do IDK apontam para um aumento de dias com desconforto pelo calor entre 2021 e 2080. A principal tendência de aumento se dá na segunda metade desse período, entre 2051 e 2080. Na porção norte do Nordeste deve predominar dias com desconforto pelo calor já entre 2021 e 2050. Na porção leste a prevalência de dias com desconforto pelo calor se dá no período de 2051 a 2080, e na parte centro-oeste da região, que no período de referência, registrou menos de 1% dos dias com desconforto pelo calor, deve entre 2021 a 2050 ter 7% dos seus dias nessa classificação, atingindo 48% dos dias desconfortáveis pelo calor; (iv) Por meio do uso dos satélites Landsat 5 e 8, na banda termal, foi possível identificar ilhas de calor na áreas pré-selecionadas, por meio da obtenção da temperatura de superfície. Para o IDK, apesar desse índice, de forma geral, apresentar a situação de conforto, para algumas áreas foram observados situações de desconforto e estresse térmico devido ao calor, principalmente, no ano de 2016. O uso de dados observados fez-se necessário com o intuito em corroborar com as informações dos satélites. / The objective of this study was to evaluate the impacts of climate change on the degree of comfort and/or thermal discomfort felt by the population of urban areas of the Northeast Region of Brazil. For this study, data from the 96 meteorological stations of the National Institute of Meteorology (INMET), distributed throughout the study region, were used. Initially, it was tried to show the behavior of the meteorological variables temperature and precipitation, from the year of 1961 to the year 2014, through indices that evaluate trends of occurrence of climatic extremes. The impacts of climate change were investigated based on the average of the results of four global climate models, ECHAM5-OM, HADGEM2-ES, BCM2 and CNRM-CM3, for two scenarios of greenhouse gas emissions, A1B and A2, which had their future projections regionalized for the period 2021-2080 with employment Statistical downscaling technique. In order to evaluate thermal comfort/discomfort, the Kawamura Discomfort Index (IDK) was used, where it was possible to evaluate the consequences of climatic changes in the degree of thermal comfort/discomfort in the Northeast region, through a future analysis For this index. Finally, through the use of the remote sensing technique, it was tried to identify heat islands in pre-selected urban areas, as well as to evaluate if there was an expansion of the urban spot and the behavior of the human thermal comfort in these areas. The results showed that: (i) Through the use of indices that evaluate extreme trends, during the years 1961 to 2014, there was a significant decrease in rainfall throughout the region, as well as an increase in both maximum temperatures As minimums; (ii) There may be a reduction in precipitation in the respective rainy periods of the northeastern subregions, an increase in maximum temperatures in the first semester, and a decrease in large areas of the northern Northeast sector in the second half of the year, mainly in scenario A2. For the minimum temperatures, the results show a tendency to increase throughout the year, with emphasis on the winter months, throughout the region; (iii) Analyzes of the IDK scenarios point to an increase in days with heat discomfort between 2021 and 2080. The main trend of increase is in the second half of this period, between 2051 and 2080. In the northern part of the Northeast, With discomfort from the heat already between 2021 and 2050. In the eastern part the prevalence of days with heat discomfort occurs in the period from 2051 to 2080, and in the central-western part of the region, which in the reference period, recorded less than 1% Of the days with heat discomfort, should between 2021 and 2050 have 7% of their days in this classification, reaching 48% of the days uncomfortable by the heat; (iv) Using the Landsat 5 and 8 satellites in the thermal band, it was possible to identify heat islands in the pre-selected areas by obtaining the surface temperature. For IDK, in spite of this index, in general, to present the comfort situation, for some areas were observed situations of discomfort and heat stress due to heat, mainly in the year 2016. The use of observed data was necessary with the intention to corroborate with the information of the satellites.
87

Avaliação do comportamento térmico do protótipo habitacional Alvorada

Morello, Alessandro January 2005 (has links)
O presente trabalho trata da verificação, in loco, do comportamento térmico de um protótipo de edificação térrea unifamiliar, de padrão popular, construído no Campus da Universidade Federal do Rio Grande do Sul, na cidade de Porto Alegre/RS (30º 02' S; 51º 13'O). A edificação, denominada “protótipo Alvorada”, foi desenvolvida a partir dos princípios e pressupostos básicos de sustentabilidade. O projeto original considerou os aspectos climáticos do local de implantação e buscou minimizar a utilização de materiais poluentes, tóxicos ou de alto conteúdo energético. Durante as quatro estações, em um período de doze meses (entre maio de 2003 e maio de 2004), foram realizadas medições em intervalos horários de diversas variáveis ambientais no interior da edificação. Os dados internos foram comparados com os dados externos obtidos em uma estação meteorológica localizada nas imediações do protótipo. O principal critério utilizado para a avaliação do comportamento térmico do protótipo Alvorada, foi o diagrama bioclimático de Givoni (1992) para países em desenvolvimento e de clima quente. Os resultados indicaram que, durante o ano de monitoramento, o número de horas de conforto foi triplicado no interior do protótipo (em relação às condições externas). A construção conseguiu amenizar os valores extremos de temperatura e reduziu consideravelmente o número de horas com umidade relativa superior a 80%.
88

Avaliação das instalações em aviários de postura conforme aspectos de conforto térmico na região de Bastos

Mattos, Juliana Medeiros de [UNESP] 26 February 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:44Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-02-26Bitstream added on 2014-06-13T19:52:24Z : No. of bitstreams: 1 mattos_jm_me_botfca.pdf: 402258 bytes, checksum: 1bc6726b53a04a538af4569ca209e009 (MD5) / O objetivo do trabalho foi apresentar análises e comparações sobre o desempenho térmico de um galpão para aves de postura, na região de Bastos, estado de São Paulo, adaptado a partir de alternativas naturais de acondicionamento, tendo como referências um galpão não adaptado, ou seja, de tipologia mais comum na região e outro acondicionado artificialmente. Os parâmetros avaliados foram: o Índice de Temperatura e Umidade (ITU), o Índice de Temperatura de Globo Negro, Umidade e a Carga Térmica de Radiação (CTR) – foram calculados a partir de medidas de temperatura de bulbo seco, temperatura de bulbo úmido, temperatura de globo negro e velocidade do ar. As medições foram realizadas, nos ambientes internos e externo, em quatro horários (5, 11, 15 e 16 horas) e duas estações (final da primavera e inicio do verão), durante dez dias consecutivos. Os resultados obtidos permitiram concluir que o galpão naturalmente acondicionado (NA) apresentou desempenho intermediário em relação aos demais, possibilitando o controle do ambiente em níveis adequados, somente, durante a primavera. Em todas as situações analisadas, o horário das 15 horas foi o que trouxe mais desconforto / The work aimed at presenting analyses and comparisons of the thermal performance of a laying hens housing in the region of Bastos, in the state of São Paulo, adapted from natural alternatives of acclimatization, having a not adapted housing as reference, that is, of a more common typology in the area, and another one, artificially acclimatized. The index evaluated was the temperature and humidity (THI), the black globe temperature and humidity index (GTHI) and the thermal radiation charge (TRC). Were calculated from the measurement of the temperature of dry bulb, temperature of humid bulb, temperature of black globe and air speed. The measurements were made both in the intern and the extern environment, at four times (5, 11, 15 and 16 o´clock) and in two seasons (late spring and early summer), for ten days in a row. The results allow us to conclude that the house naturally acclimatized (NA) has presented intermediate performance as compared with the others, making it to possible to control environment at adequate levels only during spring. In all the situations analyzed, the o´clock time has been the one that brought less comfort
89

Avaliação da ventilação e insolação em edificações na região de Bauru - SP

Donida, Mônica Maria [UNESP] 09 1900 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:44Z (GMT). No. of bitstreams: 0 Previous issue date: 2002-09Bitstream added on 2014-06-13T20:12:56Z : No. of bitstreams: 1 donida_mm_me_botfca.pdf: 2676837 bytes, checksum: f585c306c4250fb187dcf531f6fdf037 (MD5) / O objetivo principal deste trabalho foi o de analisar algumas edificações de abrigos animais e destinadas à habitação popular, tanto no meio rural como no urbano, existentes na região de Bauru – SP, e apresentar sugestões arquitetônicas que sejam tecnicamente viáveis e de baixo custo, de forma a melhorá-las em termos de conforto térmico. Para isso, foi realizado um breve histórico sobre o panorama destas edificações e seu sistema de ventilação e insolação, objetivando torná-las mais confortáveis. Foram propostos, também, dispositivos de proteção solar capazes de reduzir a carga térmica incidente sobre as mesmas bem como o direcionamento do fluxo da ventilação. / The chief purpose of this study is to analyze some animal shelter structures and the ones designed for public housing, both in the rural and urban areas situated in the region of Bauru – SP. It is also intended to present feasible technical and economic architectonic suggestions with the aim of enhancing their thermal comfort. For this reason a brief report about these structures was carried out and their ventilation and insulation system with view to make them more comfortable. Solar protection devices capable of reducing the heat load, which falls upon them, and the ventilation flux direction, were also presented. Considering the comfort rate differences for each user, anent climatic, human and architectonic variable, to adjust the thermo regulator of each user. Therefore solutions were proposed to be employed in a simple way, that is, without high-qualified manual work, with available resources to make these solutions both economically and technically feasible for the existing structures.
90

Avaliação das instalações em aviários de postura conforme aspectos de conforto térmico na região de Bastos /

Mattos, Juliana Medeiros de, 1977- January 2007 (has links)
Orientador: Luiz Antônio Targa / Coorientador: Marco Antônio Martin Biaggioni / Banca: José Roberto Corrêa Saglietti / Banca: Ana Beatriz Rocha de Castro Lopes / Resumo: O objetivo do trabalho foi apresentar análises e comparações sobre o desempenho térmico de um galpão para aves de postura, na região de Bastos, estado de São Paulo, adaptado a partir de alternativas naturais de acondicionamento, tendo como referências um galpão não adaptado, ou seja, de tipologia mais comum na região e outro acondicionado artificialmente. Os parâmetros avaliados foram: o Índice de Temperatura e Umidade (ITU), o Índice de Temperatura de Globo Negro, Umidade e a Carga Térmica de Radiação (CTR) - foram calculados a partir de medidas de temperatura de bulbo seco, temperatura de bulbo úmido, temperatura de globo negro e velocidade do ar. As medições foram realizadas, nos ambientes internos e externo, em quatro horários (5, 11, 15 e 16 horas) e duas estações (final da primavera e inicio do verão), durante dez dias consecutivos. Os resultados obtidos permitiram concluir que o galpão naturalmente acondicionado (NA) apresentou desempenho intermediário em relação aos demais, possibilitando o controle do ambiente em níveis adequados, somente, durante a primavera. Em todas as situações analisadas, o horário das 15 horas foi o que trouxe mais desconforto / Abstract: The work aimed at presenting analyses and comparisons of the thermal performance of a laying hens housing in the region of Bastos, in the state of São Paulo, adapted from natural alternatives of acclimatization, having a not adapted housing as reference, that is, of a more common typology in the area, and another one, artificially acclimatized. The index evaluated was the temperature and humidity (THI), the black globe temperature and humidity index (GTHI) and the thermal radiation charge (TRC). Were calculated from the measurement of the temperature of dry bulb, temperature of humid bulb, temperature of black globe and air speed. The measurements were made both in the intern and the extern environment, at four times (5, 11, 15 and 16 o'clock) and in two seasons (late spring and early summer), for ten days in a row. The results allow us to conclude that the house naturally acclimatized (NA) has presented intermediate performance as compared with the others, making it to possible to control environment at adequate levels only during spring. In all the situations analyzed, the o'clock time has been the one that brought less comfort / Mestre

Page generated in 0.0355 seconds