11

Efeito do fator cavitário na resistência adesiva à dentina de um sistema restaurador à base de silorano / C factor effect on bond strength of a restorative system based on silorane

Rebecca Cruz 07 February 2012 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo deste estudo foi avaliar o efeito do fator C na resistência adesiva à dentina humana de um compósito à base de silorano, comparando-o com um compósito à base de metacrilato. Foram utilizados 40 molares humanos hígidos. Em metade da amostra foi realizado um preparo do tipo Classe I, com dimensões de 4x4 mm e 2 mm de profundidade, enquanto na outra metade foi realizado um preparo virtual (flat) com auxílio de uma matriz de teflon branco, com as mesmas dimensões da cavidade (4x4x2 mm), apoiada na superfície de dentina exposta. Cada grupo foi divido em dois, de acordo com o sistema restaurador: Sistema Adesivo P90 e resina Filtek P90; Adper Scotchbond Multiuso e resina Filtek Z350 XT (3M ESPE). Após a aplicação do sistema adesivo segundo as especificações do fabricante, as cavidades (real e virtual) foram preenchidas com as resinas (Z350 XT e P90) em dois incrementos. Foi realizada a fotoativação de cada incremento durante 25s. Após uma semana, as coroas foram seccionadas, obtendo-se espécimes constituídos de resina/dente na forma de um paralelepípedo (palitos). Estes palitos foram utilizados para o teste de microtração (Emic), onde a resistência adesiva na unidade MPa foi calculada. Os resultados foram avaliados estatisticamente pelo teste de análise de variância ANOVA One-Way (p = 0,05), e pelo teste de múltiplas comparações Student Newman Keuls. Foi observada uma diferença estatística entre a resina P90 (flat= 16,137,7 MPa e Cavidade= 16,759,0 MPa) e a Z350 XT (flat= 25,8211,6 MPa e Cavidade=24,4713,5 MPa), independentemente do tipo de cavidade restaurada. E não foi possível observar diferença estatística entre os tipos de cavidades (real ou virtual) restauradas com a mesma resina. Através dos testes realizados, foi possível concluir que: o fator C não afetou a resistência adesiva dos dois sistemas restauradores utilizados, e o tipo de sistema restaurador afeta a resistência adesiva, sendo que o sistema à base de silorano apresenta resultados inferiores ao de metacrilato. / The purpose of this study is to evaluate the effect of the C factor in the bond strength of a composite based on silorane to human dentin, comparing its results with a methacrylate-based composite. A total of 40 human molars were used. In half of this sample was used a Class I standard preparation method, comprising the dimensions of 4x4 mm and 2 mm deep, while with the other half was used a virtual preparation method (flat), being applied a white Teflon matrix, respecting the same dimensions cavity (4x4x2 mm), supported on the surface of exposed dentin. Each group was divided into two parts, in accordance with the 2 different restorative systems: P90 Adhesive System and Filtek P90; Filtek Z350 XT and Adper Scotchbond Multipurpose (3 ESPE). Based on manufacturer's specifications the adhesive system was applied , the cavities (real and virtual) were filled with the resins (Z350 XT and P90) in two increments. Polymerization was performed for each increment during 25 seconds. After one week, the crowns were sectioned, obtaining specimens made of resin / tooth in the form of a parallelepiped (stick-shaped). These sticks were used in a microtensile test (Emic), where the bond strength was calculated in Mpa unit . It was used the analysis of variance One-Way ANOVA (p = 0.05) and also, the Student Newman Keuls test for multiple comparisons to evaluate the results statistically. It was observed a statistical difference between the P90 resin (flat = 16.137.7 MPa and cavity = 16.759.0 MPa) and Z350 XT (flat = 25.8211.6 MPa and cavity = 24.4713.5 MPa), regardless of the cavity restored. And it was not possible to observe a statistical difference between the types of cavities (real or flat) restored with the same composite. The conclusion of the tests is: the C factor did not affect the bond strength of two restorative systems applied, and the type of restorative system affects the bond strength, and the system based on silorano presents inferior results than to methacrylate system.
12

Ionômero de vidro resinoso nanoparticulado: avaliação de propriedades físico-químicas e biológicas / Resin modified nano ionomer: physical-chemical and biological evaluation

Garcia Júnior, Edélcio 15 October 2009 (has links)
O objetivo deste estudo foi avaliar o cimento de ionômero de vidro modificado por resina de nanopartículas Ketac&trade;N100, por meio de três metodologias diferentes: resposta tecidual em subcutâneo de camundongos isogênicos, liberação de flúor e tensão de contração de polimerização, in vitro. Foram utilizados 90 camundongos isogênicos da linhagem BALB/c, divididos em 9 grupos (n=10), nos quais foram implantados tubos de polietileno contendo o Ketac&trade; 100, ChemFilR (ionômero de vidro convencional) ou tubo vazio. Nos períodos experimentais de 7, 21 e 63 dias o tubo e o tecido adjacente foram removidos para análise microscópica. Para o ensaio de avaliação da tensão de contração de polimerização, foram utilizados dois bastões de vidro fixados a uma máquina de ensaio universal. Nos bastões foi acoplado um extensômetro para medição da força de contração de polimerização de cinco materiais (Resina Filtek&trade;Z350, CompoglassR F, VitremerMR, Ketac&trade;N100 e ChemFilR), com 10 corpos de prova para cada material. Para o ensaio de liberação de flúor, foram confeccionados 8 corpos de prova de 3 diferentes materiais (Ketac&trade; 100, Vidrion R e Resina Filtek&trade; Z250), colocados individualmente em 1 ml de saliva artificial. O corpo de prova foi trocado a cada dia por 15 dias e a solução obtida utilizada para a leitura do íon fluoreto.Os resultados microscópicos evidenciaram que a inflamação presente na abertura dos tubos, aos 7 dias, sofreu uma diminuição em área e espessura até os 63 dias, nos 2 materiais e no grupo controle. Comparando a área da reação inflamatória o Ketac&trade;N100 foi diferente estatisticamente do ChemFilR, nos períodos de 7 e 21 dias (p>0,05), com uma área menor para o Ketac&trade;N100. A espessura da reação inflamatória nos períodos de 7 e 21 dias apresentou valores semelhantes entre o Ketac&trade;N100 e ChemFilR (p>0,05). Aos 63 dias, os valores foram estatisticamente diferentes, com um pequeno aumento de espessura para o Ketac&trade;N100. Os valores de tensão de contração de polimerização obtidos seguiram a seguinte ordem crescente: ChemFilR < VitremerMR < Ketac&trade;N100 < CompoglassR F ~ Filtek&trade;Z350 (p>0,05). Quando comparados dois a dois, o ionômero modificado por resina de nanopartículas Ketac&trade;N100 se aproximou mais dos valores da resina Filtek&trade; Z350 (p>0,05) do que do ionômero de vidro convencional ChemFilR (p<0,05). A sua liberação de flúor ocorreu mais significativamente nos dois primeiros dias, com valores médios 33% menores em comparação ao Vidrion R. Concluímos que o ionômero resinoso nanoparticulado Ketac&trade;N100 é um material que induz uma resposta inflamatória tecidual satisfatória em subcutâneo de camundongos isogênicos. Sua contração de polimerização foi menor do que de a resina Filtek&trade; Z350 e a liberação de flúor foi um terço menor do que a dos ionômeros convencionais. / The aim of this study was to evaluate the resin modified nano ionomer Ketac&trade;N100, by three different methodologies: tissue response in of isogenic mice subcutaneous, fluoride release and shrinkage stress of polymerization in vitro. We used 90 isogenic mice (BALB / c), divided into 9 groups (n = 10), which were implanted with polyethylene tubes containing Ketac&trade; 100, ChemFilR (Ionomer conventional) or empty tube. In the experimental periods of 7, 21 and 63 days the tube and the surrounding tissue were removed for microscopic analysis. To evaluating the stress of contraction of polymerization, we used two glass rods attached to a universal testing machine. In the rods was attached to an extensometer to obtain the measure of the polymerization shrinkage strength of five materials (resin Filtek&trade;Z350, CompoglassR F, VitremerMR F, Ketac&trade; 100 and ChemFilR), with 10 specimens for each material. In the fluoride release test, 8 specimens of 3 different materials (Ketac&trade; 100, Vidrion R and Resin Filtek&trade; Z250) placed individually in 1 ml of artificial saliva. The specimens were changed each day for 15 days and we use this solution used for reading the fluoride ion. The microscopic results showed that the inflammation in the opening of the tubes at 7 days decreased in area and thickness up to 63 days in 2 materials and the control group. Comparing the inflammatory reaction area, Ketac&trade;N100 was statistically different from ChemFilR, in periods of 7 and 21 days (p> 0.05), with a smaller area for Ketac&trade;N100. The inflammatory reaction in the periods of 7 and 21 days showed similar values between the Ketac&trade;N100 and ChemFilR (p> 0.05). At 63 days, the values were statistically different, with a small increase in thickness to Ketac&trade;N100. The values of polymerization shrinkage strength obtained after polymerization followed this ascending order: ChemFilR < VitremerMR F < Ketac&trade; 100 < CompoglassR F ~ Filtek&trade;Z350 (p> 0.05). When compared two by two, the resin modified nano ionomer Ketac&trade;N100 approached most of the values of resin Filtek&trade; Z350(p> 0.05) than the conventional glass Ionomer ChemFilR (p <0.05). The fluoride release occurred more significantly in the first two days, with average 33% lower compared with Vidrion R. We conclude that the resin modified nano ionomer Ketac&trade;N100 is a material that induces an satisfactory inflammatory response in subcutaneous tissue of isogenic mice. Its polymerization shrinkage strength was lower than the resin Filtek&trade; Z350 and fluoride release was a third lower than the conventional glass ionomer.
13

Efeito da base de cimento de ionômero de vidro convencional e modificado por resina na interface adesiva dente/resina composta após termociclagem / Effect of conventional and resin-modified glass ionomer cements base on tooth/composite resin adhesive interface after termocycling

Sampaio, Paula Costa Pinheiro 24 April 2009 (has links)
Resinas compostas apresentam contração de polimerização e a tensão gerada durante essa polimerização compete com a força adesiva na interface dente/restauração. A técnica incremental e o uso de bases com alta resiliência e módulo de elasticidade próximo ao das estruturas dentárias são técnicas desenvolvidas para tentar diminuir a tensão originada pela contração de polimerização. O presente estudo teve como objetivo analisar a influência do uso de bases de cimento de ionômero de vidro convencional e modificado por resina na qualidade e adaptação marginal na interface dentina/resina composta, após a ciclagem térmica, usando testes de resistência adesiva e análise em microscopia confocal de varredura a laser. Foram confeccionadas cavidades na face oclusal (4,5mm x 3mm x 5mm) de 60 molares humanos extraídos divididos em 6 grupos: 1 e 4 - sistema adesivo (AdperTM Single Bond; 3M ESPE) + resina composta (Filtek Z250; 3M ESPE); 2 e 5 - base de cimento de ionômero de vidro convencional (Ketac Molar Easymix; 3M ESPE) + sistema adesivo + resina composta; e 3 e 6 - base de cimento de ionômero de vidro modificado por resina (Vitrebond; 3M ESPE) + sistema adesivo + resina composta. Os grupos 4, 5 e 6 sofreram um processo de termociclagem com dois banhos (5ºC 55ºC) durante 30 segundos em 5.000 ciclos. Após 24 horas, os dentes foram seccionados em uma máquina de cortes com disco de diamante em espessura de 0,8mm. Uma fatia de cada dente foi separada aleatoriamente para análise em Microscópio Confocal para observação e mensuração de possíveis fendas marginais internas. As demais fatias foram seccionadas para a confecção de palitos (0,8mm X 0,8mm) que foram submetidos a testes de microtração em uma máquina de ensaios universal EMIC. Os resultados de resistência adesiva foram submetidos à análise de variância a um critério (ANOVA) e ao teste t-Student (p< 0,05). A presença de fendas foi avaliada com o teste da razão de verossimilhança ou teste exato de Fisher e os valores de comprimento das fendas foram avaliados pelo teste não paramétrico de Kruskal-Wallis (p<0,05). Não foram observadas diferenças estatisticamente significantes na resistência adesiva em nenhum dos grupos sem termociclagem (G1 19,28 MPa; G2 16,29 MPa; e G3 15,95MPa) ou com termociclagem (G4 19,74 MPa; G5 16,58 MPa; e G6 16,01 MPa). A análise das medidas das fendas revelou não haver diferença estatisticamente significante entre os grupos G1 (1,4µm), G2 (2,88µm) e G3 (4,63µm) e entre os grupos G4 (4,2µm), G5 (12,5µm) e G6 (5,4µm). No entanto, a termociclagem determinou um aumento do tamanho médio das fendas no grupo com base de CIV convencional (G4 12,5µm). A análise da presença ou ausência de fendas mostrou um aumento na porcentagem do número de fendas quando os espécimes foram termociclados, para os grupos sem base e com base de CIV (G1 - 30%; G2 - 25% G3 25%; G4 - 53,33%; G5 70%; e G6 30%). Os resultados mostraram, ainda, não haver relação entre o comprimento e a formação das fendas com a resistência adesiva. Conclui-se, portanto, que o uso de base de cimento de ionômero de vidro modificado por resina mantém mais estável a qualidade da interface adesiva dentina/resina composta após envelhecimento artificial com termociclagem. / Polymerization shrinkage leads to a tension into dentin/resin composite interface that can cause marginal discoloration, poor marginal adaptation, secondary caries and post-operative sensitivity. The incremental restorative technique and the use of a resilient liner with a modulus of elasticity similar to dental structures are techniques used to decrease the shrinkage polymerization tension. The aim of this in vitro study was to analyze the effect of glass-ionomer cement as a liner on the adhesive interface dentin/resin of occlusal restorations after thermocycling aging. Occlusal cavities were prepared sixty human extracted molars, divided into six groups: 1 and 4 with no liner; 2 and 5 glass-ionomer cement (Ketac Molar Easymix); and 3 and 6 resin-modified glass-ionomer cement (Vitrebond). Resin composite (Filtek Z250) was placed after application of adhesive system Adper Single Bond 2. Adhesive system was mixed with fluorescent reagent (Rhodamine B) to allow confocal microscopy analysis. After that, the specimens of groups 4, 5, 6 were thermocycled into 2 baths (5ºC 55ºC) of 30s each in 5.000 cycles. After this period, teeth were sectioned in 0,8mm slices. One slice of each tooth was randomly selected for analysis in Confocal Microscopy. The other ones were sectioned in sticks, which were submitted to micro-tensile test. The results of adhesive strength were analyzed by one way ANOVA and t-Student tests. Gap formation were analysed by Fisher test and the gaps size were analyzed by Kruskal-Wallis test (p<0,05). No statistical difference on adhesive resistance was showed between groups. Confocal Microscopy analysis showed gaps with a higher mean sizes for group 4 (12,5µm) and higger percentage of marginal gaps formation for the thermocycled groups (G1 - 30%; G2 - 25%; G4 - 53,33%; G5 70%). Groups 3 (25%) and 6 (30%) showed the lowest percentage of marginal gap formation. The results revealed that gap formation is not related to adhesive strength. It can be concluded, therefore, that the use of a resin-modified-glassionomer cement liner showed less gap formation on dentin/composite adhesive interface after artificial aging compared to conventional glass ionomer cement liner and restorations with no lining.
14

Efeito da base de cimento de ionômero de vidro convencional e modificado por resina na interface adesiva dente/resina composta após termociclagem / Effect of conventional and resin-modified glass ionomer cements base on tooth/composite resin adhesive interface after termocycling

Paula Costa Pinheiro Sampaio 24 April 2009 (has links)
Resinas compostas apresentam contração de polimerização e a tensão gerada durante essa polimerização compete com a força adesiva na interface dente/restauração. A técnica incremental e o uso de bases com alta resiliência e módulo de elasticidade próximo ao das estruturas dentárias são técnicas desenvolvidas para tentar diminuir a tensão originada pela contração de polimerização. O presente estudo teve como objetivo analisar a influência do uso de bases de cimento de ionômero de vidro convencional e modificado por resina na qualidade e adaptação marginal na interface dentina/resina composta, após a ciclagem térmica, usando testes de resistência adesiva e análise em microscopia confocal de varredura a laser. Foram confeccionadas cavidades na face oclusal (4,5mm x 3mm x 5mm) de 60 molares humanos extraídos divididos em 6 grupos: 1 e 4 - sistema adesivo (AdperTM Single Bond; 3M ESPE) + resina composta (Filtek Z250; 3M ESPE); 2 e 5 - base de cimento de ionômero de vidro convencional (Ketac Molar Easymix; 3M ESPE) + sistema adesivo + resina composta; e 3 e 6 - base de cimento de ionômero de vidro modificado por resina (Vitrebond; 3M ESPE) + sistema adesivo + resina composta. Os grupos 4, 5 e 6 sofreram um processo de termociclagem com dois banhos (5ºC 55ºC) durante 30 segundos em 5.000 ciclos. Após 24 horas, os dentes foram seccionados em uma máquina de cortes com disco de diamante em espessura de 0,8mm. Uma fatia de cada dente foi separada aleatoriamente para análise em Microscópio Confocal para observação e mensuração de possíveis fendas marginais internas. As demais fatias foram seccionadas para a confecção de palitos (0,8mm X 0,8mm) que foram submetidos a testes de microtração em uma máquina de ensaios universal EMIC. Os resultados de resistência adesiva foram submetidos à análise de variância a um critério (ANOVA) e ao teste t-Student (p< 0,05). A presença de fendas foi avaliada com o teste da razão de verossimilhança ou teste exato de Fisher e os valores de comprimento das fendas foram avaliados pelo teste não paramétrico de Kruskal-Wallis (p<0,05). Não foram observadas diferenças estatisticamente significantes na resistência adesiva em nenhum dos grupos sem termociclagem (G1 19,28 MPa; G2 16,29 MPa; e G3 15,95MPa) ou com termociclagem (G4 19,74 MPa; G5 16,58 MPa; e G6 16,01 MPa). A análise das medidas das fendas revelou não haver diferença estatisticamente significante entre os grupos G1 (1,4µm), G2 (2,88µm) e G3 (4,63µm) e entre os grupos G4 (4,2µm), G5 (12,5µm) e G6 (5,4µm). No entanto, a termociclagem determinou um aumento do tamanho médio das fendas no grupo com base de CIV convencional (G4 12,5µm). A análise da presença ou ausência de fendas mostrou um aumento na porcentagem do número de fendas quando os espécimes foram termociclados, para os grupos sem base e com base de CIV (G1 - 30%; G2 - 25% G3 25%; G4 - 53,33%; G5 70%; e G6 30%). Os resultados mostraram, ainda, não haver relação entre o comprimento e a formação das fendas com a resistência adesiva. Conclui-se, portanto, que o uso de base de cimento de ionômero de vidro modificado por resina mantém mais estável a qualidade da interface adesiva dentina/resina composta após envelhecimento artificial com termociclagem. / Polymerization shrinkage leads to a tension into dentin/resin composite interface that can cause marginal discoloration, poor marginal adaptation, secondary caries and post-operative sensitivity. The incremental restorative technique and the use of a resilient liner with a modulus of elasticity similar to dental structures are techniques used to decrease the shrinkage polymerization tension. The aim of this in vitro study was to analyze the effect of glass-ionomer cement as a liner on the adhesive interface dentin/resin of occlusal restorations after thermocycling aging. Occlusal cavities were prepared sixty human extracted molars, divided into six groups: 1 and 4 with no liner; 2 and 5 glass-ionomer cement (Ketac Molar Easymix); and 3 and 6 resin-modified glass-ionomer cement (Vitrebond). Resin composite (Filtek Z250) was placed after application of adhesive system Adper Single Bond 2. Adhesive system was mixed with fluorescent reagent (Rhodamine B) to allow confocal microscopy analysis. After that, the specimens of groups 4, 5, 6 were thermocycled into 2 baths (5ºC 55ºC) of 30s each in 5.000 cycles. After this period, teeth were sectioned in 0,8mm slices. One slice of each tooth was randomly selected for analysis in Confocal Microscopy. The other ones were sectioned in sticks, which were submitted to micro-tensile test. The results of adhesive strength were analyzed by one way ANOVA and t-Student tests. Gap formation were analysed by Fisher test and the gaps size were analyzed by Kruskal-Wallis test (p<0,05). No statistical difference on adhesive resistance was showed between groups. Confocal Microscopy analysis showed gaps with a higher mean sizes for group 4 (12,5µm) and higger percentage of marginal gaps formation for the thermocycled groups (G1 - 30%; G2 - 25%; G4 - 53,33%; G5 70%). Groups 3 (25%) and 6 (30%) showed the lowest percentage of marginal gap formation. The results revealed that gap formation is not related to adhesive strength. It can be concluded, therefore, that the use of a resin-modified-glassionomer cement liner showed less gap formation on dentin/composite adhesive interface after artificial aging compared to conventional glass ionomer cement liner and restorations with no lining.
15

Ionômero de vidro resinoso nanoparticulado: avaliação de propriedades físico-químicas e biológicas / Resin modified nano ionomer: physical-chemical and biological evaluation

Edélcio Garcia Júnior 15 October 2009 (has links)
O objetivo deste estudo foi avaliar o cimento de ionômero de vidro modificado por resina de nanopartículas Ketac&trade;N100, por meio de três metodologias diferentes: resposta tecidual em subcutâneo de camundongos isogênicos, liberação de flúor e tensão de contração de polimerização, in vitro. Foram utilizados 90 camundongos isogênicos da linhagem BALB/c, divididos em 9 grupos (n=10), nos quais foram implantados tubos de polietileno contendo o Ketac&trade; 100, ChemFilR (ionômero de vidro convencional) ou tubo vazio. Nos períodos experimentais de 7, 21 e 63 dias o tubo e o tecido adjacente foram removidos para análise microscópica. Para o ensaio de avaliação da tensão de contração de polimerização, foram utilizados dois bastões de vidro fixados a uma máquina de ensaio universal. Nos bastões foi acoplado um extensômetro para medição da força de contração de polimerização de cinco materiais (Resina Filtek&trade;Z350, CompoglassR F, VitremerMR, Ketac&trade;N100 e ChemFilR), com 10 corpos de prova para cada material. Para o ensaio de liberação de flúor, foram confeccionados 8 corpos de prova de 3 diferentes materiais (Ketac&trade; 100, Vidrion R e Resina Filtek&trade; Z250), colocados individualmente em 1 ml de saliva artificial. O corpo de prova foi trocado a cada dia por 15 dias e a solução obtida utilizada para a leitura do íon fluoreto.Os resultados microscópicos evidenciaram que a inflamação presente na abertura dos tubos, aos 7 dias, sofreu uma diminuição em área e espessura até os 63 dias, nos 2 materiais e no grupo controle. Comparando a área da reação inflamatória o Ketac&trade;N100 foi diferente estatisticamente do ChemFilR, nos períodos de 7 e 21 dias (p>0,05), com uma área menor para o Ketac&trade;N100. A espessura da reação inflamatória nos períodos de 7 e 21 dias apresentou valores semelhantes entre o Ketac&trade;N100 e ChemFilR (p>0,05). Aos 63 dias, os valores foram estatisticamente diferentes, com um pequeno aumento de espessura para o Ketac&trade;N100. Os valores de tensão de contração de polimerização obtidos seguiram a seguinte ordem crescente: ChemFilR < VitremerMR < Ketac&trade;N100 < CompoglassR F ~ Filtek&trade;Z350 (p>0,05). Quando comparados dois a dois, o ionômero modificado por resina de nanopartículas Ketac&trade;N100 se aproximou mais dos valores da resina Filtek&trade; Z350 (p>0,05) do que do ionômero de vidro convencional ChemFilR (p<0,05). A sua liberação de flúor ocorreu mais significativamente nos dois primeiros dias, com valores médios 33% menores em comparação ao Vidrion R. Concluímos que o ionômero resinoso nanoparticulado Ketac&trade;N100 é um material que induz uma resposta inflamatória tecidual satisfatória em subcutâneo de camundongos isogênicos. Sua contração de polimerização foi menor do que de a resina Filtek&trade; Z350 e a liberação de flúor foi um terço menor do que a dos ionômeros convencionais. / The aim of this study was to evaluate the resin modified nano ionomer Ketac&trade;N100, by three different methodologies: tissue response in of isogenic mice subcutaneous, fluoride release and shrinkage stress of polymerization in vitro. We used 90 isogenic mice (BALB / c), divided into 9 groups (n = 10), which were implanted with polyethylene tubes containing Ketac&trade; 100, ChemFilR (Ionomer conventional) or empty tube. In the experimental periods of 7, 21 and 63 days the tube and the surrounding tissue were removed for microscopic analysis. To evaluating the stress of contraction of polymerization, we used two glass rods attached to a universal testing machine. In the rods was attached to an extensometer to obtain the measure of the polymerization shrinkage strength of five materials (resin Filtek&trade;Z350, CompoglassR F, VitremerMR F, Ketac&trade; 100 and ChemFilR), with 10 specimens for each material. In the fluoride release test, 8 specimens of 3 different materials (Ketac&trade; 100, Vidrion R and Resin Filtek&trade; Z250) placed individually in 1 ml of artificial saliva. The specimens were changed each day for 15 days and we use this solution used for reading the fluoride ion. The microscopic results showed that the inflammation in the opening of the tubes at 7 days decreased in area and thickness up to 63 days in 2 materials and the control group. Comparing the inflammatory reaction area, Ketac&trade;N100 was statistically different from ChemFilR, in periods of 7 and 21 days (p> 0.05), with a smaller area for Ketac&trade;N100. The inflammatory reaction in the periods of 7 and 21 days showed similar values between the Ketac&trade;N100 and ChemFilR (p> 0.05). At 63 days, the values were statistically different, with a small increase in thickness to Ketac&trade;N100. The values of polymerization shrinkage strength obtained after polymerization followed this ascending order: ChemFilR < VitremerMR F < Ketac&trade; 100 < CompoglassR F ~ Filtek&trade;Z350 (p> 0.05). When compared two by two, the resin modified nano ionomer Ketac&trade;N100 approached most of the values of resin Filtek&trade; Z350(p> 0.05) than the conventional glass Ionomer ChemFilR (p <0.05). The fluoride release occurred more significantly in the first two days, with average 33% lower compared with Vidrion R. We conclude that the resin modified nano ionomer Ketac&trade;N100 is a material that induces an satisfactory inflammatory response in subcutaneous tissue of isogenic mice. Its polymerization shrinkage strength was lower than the resin Filtek&trade; Z350 and fluoride release was a third lower than the conventional glass ionomer.
16

Síntese de monômeros siloxano-oxiranos para aplicação em Odontologia / Synthesis of siloxane-oxirane monomers for use in dentistry

Leal, Fernanda Barbosa 19 December 2012 (has links)
Made available in DSpace on 2014-08-20T14:30:15Z (GMT). No. of bitstreams: 1 Dissertacao_Fernanda_Barbosa_Leal.pdf: 806160 bytes, checksum: 37717162c453100433c520a8c9d199ef (MD5) Previous issue date: 2012-12-19 / The aim of this study was synthesize, characterize and photopolymerize an alternative monomers for use in dentistry. Three siloxane-oxirane monomers were synthesized and the products conversion was followed by Fourier-transform infrared spectroscopy. The products obtained were characterized by 1H and 13C NMR and evaluated for viscosity and refractive index. The polymerization was evaluated by formulating of two experimental photoinitiation systems wich varied for the presence of 1,2 ethanediol. A ternary system with camphorquinone (CQ), ethyl 4-dimethylaminobenzoate (EDAB) and diphenyliodonium hexafluorphosphate (DPI) was used as control. The degree of conversion was accessed by FTIR and DSC-PCA. The NMR confirmed the synthesis success with 75, 87 and 55% yield for the monomers synthesized. Moreover, the presence of 1,2 ethanediol increase the degree conversion of the siloxane-oxirane monomers. This study showed simple and effective way to synthesize siloxane-oxirane monomers with a high potential for application in dental materials / O objetivo deste estudo foi sintetizar, caracterizar e fotopolimerizar monômeros alternativos para aplicação em Odontologia. Três monômeros siloxano-oxiranos foram sintetizados e a conversão de produtos foi acompanhada por espectroscopia de infravermelho por transformada de Fourier. Os produtos obtidos foram caracterizados por 1H e 13C RMN e avaliados quanto à viscosidade e índice de refração. Para investigar a polimerização, dois sistemas experimentais de fotoiniciação foram formulados, variando quanto à presença de 1,2 etanodiol. Um sistema ternário composto por canforoquinona (CQ), 4-dimetilaminobenzoato (EDAB) e difeniliodonio hexafluorfostato (DPI) foi utilizado como controle. O grau de conversão foi obtido por FTIR e DSC-PCA. As análises de RMN confirmaram a obtenção dos produtos com 75, 87 e 55% de rendimento. Além disso, a presença de 1,2 etanodiol aumentou o grau de conversão dos monômeros siloxano-oxiranos. Este estudo demonstrou um método simples e eficaz para sintetizar monômeros siloxano-oxiranos com grande potencial para aplicação em materiais dentários