• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

ASPIRAÇÃO DE CORPO ESTRANHO EM MENORES DE 15 ANOS: UMA DÉCADA DE EXPERIÊNCIA / ASPIRATION OF STRANGE BODY IN MINORS OF 15 YEARS: ONE DECADE OF EXPERIENCE

Sousa, Silvia Teresa Evangelista Vidotto de 24 September 2007 (has links)
Made available in DSpace on 2016-08-19T18:15:54Z (GMT). No. of bitstreams: 1 Silvia Teresa Evangelista.pdf: 209991 bytes, checksum: 497a2c5c02aa5d734a85bd23ce11c2b1 (MD5) Previous issue date: 2007-09-24 / Airway aspiration of foreign body (FB) is a universal problem and an important cause of morbidity and mortality especially for children and the elderly. FB aspiration was evaluated in 72 children and teenagers varying from 7 months to 15 years of age who underwent rigid bronchoscopy at the CMUH (Children Maternal University Hospital), in São Luís-MA/ Brazil, for FB aspiration in the period from 1995 to 2005. For data collecting, an index card was filled out for each patient. Epi-info and Bio-estata programs were used for processing and statistical analysis. A major prevalence of FB aspiration from 1998 through 2001 was observed. Most patients were from the countryside (55.6%). The predominant age was the firsts three years of life (81.9%). The prevalence was greater among the male sex (63.9%). In 83.3% of the cases the initial diagnosis was FB aspiration. The elapsed time between the aspiration and the bronchoscopy was greater than 72h (52.8 %). The most frequent site was the right lung (38.9 %). The most common types of FB found were of organic nature (83.3 %). The most prevailing radiological finding was hypotransparence (56.9%). Bronchitis was the most frequently reported complication related to FB aspiration (45.9%), and glottis edema was a major complication upon bronchoscopy (47.6%), with no deaths reported in the studied group. It is concluded that bronchoscopy is a safe, highly sensible and efficient procedure for the diagnosis and treatment of FB aspiration, and that a late diagnosis suggests a need for better qualification of the health professionals. / A aspiração de corpo estranho (ACE) para via aérea é um problema universal e uma importante causa de morbidade e mortalidade, especialmente em crianças e idosos. Avaliou-se a aspiração de corpo estranho em 72 crianças na faixa etária de 7 meses a 15 anos submetidas à endoscopia respiratória no Hospital Universitário Materno Infantil (HUMI) por ACE, no período de 1995 a 2005, São Luís - Maranhão. Para cada paciente estudado foi preenchida uma ficha de coleta de dados. Utilizou-se os programas Epi- Info e BioEstata para o processamento e análise estatística. Observou-se uma maior prevalência de ACE nos anos de 1998 a 2001. A maior procedência foi das cidades do interior (55,6%). A idade predominante foi nos três primeiros anos de vida (81,9%). A prevalência foi maior no sexo masculino (63,9%). Em 83,3% dos casos, o diagnóstico inicial foi de ACE. O tempo decorrido entre a aspiração e o exame endoscópico foi maior que 72h (52,8%). A localização mais freqüente foi o pulmão direito (38,9%). O tipo de corpo estranho (CE) mais encontrado foi o orgânico (83,3%). O achado radiológico mais prevalente foi a hipotransparência (56,9%). A complicação mais freqüente relacionada ao CE foi a bronquite (45,9%) A complicação relacionada ao exame endoscópico mais freqüente foi o edema de glote (47,6%), não havendo óbitos. Concluiu-se que a endoscopia respiratória mostrou-se um procedimento seguro, eficaz e de alta sensibilidade no diagnóstico e tratamento do ACE e que a demora no seu diagnóstico sugere a necessidade de melhor qualificação dos profissionais de saúde.
2

[en] MODELING OF MAGNETIC FOREIGN BODIES AND INVERSE PROBLEM SOLUTION BY NEURAL NETWORKS / [pt] MODELAGEM DE CORPOS ESTRANHOS MAGNÉTICOS E SOLUÇÃO DO PROBLEMA INVERSO POR REDES NEURAIS

JHERSON PAUL MEDINA HUACASI 12 April 2019 (has links)
[pt] A introdução de um objeto estranho ao corpo humano pode resultar de diferentes processos que abrangem desde eventos iatrogênicos oriundos de procedimentos cirúrgicos, até eventos traumáticos, ocasionados por acidentes ou violência, como disparos de arma de fogo e perfurações com objetos cortantes. A presença desses corpos estranhos dentro do organismo humano pode ocasionar problemas de saúde que vão desde dor e incômodos ao óbito. Para remoção cirúrgica, torna-se essencial a localização desses objetos, com elevada exatidão, para redução do tempo cirúrgico e garantia de sucesso do procedimento. O presente trabalho tem por objetivo ampliar o estudo do problema de localização de corpos estranhos magnéticos (intrinsicamente magnético ou por indução magnética externa) no organismo humano. Foram desenvolvidos algoritmos computacionais capazes de promover simulações dos padrões de densidade de fluxo magnético em um plano decorrentes de uma fonte extensa, representada por parâmetros modificáveis de comprimento, posição espacial e inclinação ao plano de medição. Essas simulações foram utilizadas como entrada para o treinamento de Redes Neurais Artificiais que, após treinamento, foram capazes de resolver o problema inverso, caracterizando, a partir do mapa de campo magnético, a posição espacial, tamanho (comprimento) e inclinação da fonte metálica. Os resultados obtidos indicaram melhor desempenho com o uso de sensores triaxiais, cujo erro quadrático médio, em 3640 testes, mostrou-se inferior a 2 mm na orientação espacial, a 8 mm no comprimento e a 17 graus Celsius para a inclinação da fonte magnética em relação ao plano de medição. / [en] The introduction of a foreign object into the human body may result from different processes ranging from iatrogenic events during surgical procedures to traumatic events caused by accidents or violence such as firing and piercing with sharp objects. The presence of these foreign bodies within the human body can cause health problems ranging from pain and discomfort to death. For surgical removal, it is essential to locate these objects, with high accuracy, to reduce surgical time and guarantee the success of the procedure. The objective of the present work is to contribute to the study of the localization problem of magnetic foreign bodies (intrinsically magnetic or by external magnetic induction) in the human body. The developed computational algorithms are capable of promoting simulations of magnetic flux density patterns in a plane from an extensive source, represented by modifiable parameters of length, spatial position and slope to the measurement plane. These simulations were used as input for the training of Artificial Neural Networks that, after training, were able to solve the inverse problem, characterizing, from the magnetic field map, the spatial position, size (length) and slope of the metallic source. The results indicated a better performance with the use of triaxial sensors, whose mean square error, in 3640 tests, was less than 2 mm in the spatial orientation, 8 mm in length and 17 Celsius degrees for the tilt of the magnetic source in relation to the measurement plane.
3

Telas depolipropileno revestidas por quitosana/polietilenoglicol na ocorrência de aderências peritoniais: Estudo experimental em ratas / Polypropylene meshes coated by chitosan/polyethyelene glycol in event of peritoneal adhesions: experimental study in females rats

RODRIGUES, Danilo Ferreira 25 February 2011 (has links)
Made available in DSpace on 2014-07-29T15:07:34Z (GMT). No. of bitstreams: 1 Dissert-Danilo Ferreira Rodrigues.pdf: 452744 bytes, checksum: 0d66f9b822194b140597d873ca8c4a8c (MD5) Previous issue date: 2011-02-25 / Peritoneal adhesions are highly important in clinical and surgical practice because of the potential to cause sequelae such as chronic abdominal pain, infertility and bowel obstruction; thus, preventing the formation of this process becomes a challenge for surgeons. Due to biocompatibility, bioabsorption, healing and antimicrobial properties, chitosan is a polymer which has aroused interest of researchers studying the prevention of peritoneal adhesions. The objective of this research was to determine whether the intraperitoneal implantation of polypropylene mesh coated with a film of chitosan/polyethylene glycol is effective for the prevention of adhesions in rats with induced abdominal defects. We sought to further characterize the tissue reactions in acute and chronic phases of the inflammation process, and the tissue repair processes triggered by this biomaterial and the polypropylene mesh without coating. Defect of about 1cm was made in the abdominal wall, with reference to anatomical aponeurosis of the fascia of the rectus abdominis and obliquus externus abdominis muscles, followed by the implantation of polypropylene meshes coated with chitosan / polyethylene glycol (QP Group, n= 12) and uncoated polypropylene meshes (PP group, n= 12). Six animals from each group were euthanized at four and 45 days after implantation and the involvement of the mesh area by the adhesion, the type of adhesion, the inflammation process and tissue repair, and the quantification and characterization of collagen fibers were evaluated. The average of the meshes involved by adhesions in the QP and PP groups was 39.088% and 84.024%, respectively, and the structure involved in abdominal adhesions in the QP group usually consisted of the omentum around the implant, while in the PP group, adhesions were usually on the surface of the mesh. After four days of surgery, the amount of mononuclear cells was lower in QP, but the amount of polymorphonuclear cells, fibrin and collagen fibers was in greater quantity in this group; besides, the later variable showed better spatial organization. After 45 days of biomaterials implantation, there was a reduction in the amount of inflammatory cells, and spatial organization of collagen fibers in the QP group remained strong. It is concluded that the meshes coated with the film based on chitosan/polyethylene glycol did not prevent adhesion formation, but significantly minimized the seriousness of this process. In the acute phase of inflammation and tissue repair, the foreign body reaction was less intense in the group receiving the coated polypropylene mesh, but the tissue reactions caused by the studied biomaterials were similar to the chronic phase. The mesh coated with film-based chitosan/polyethylene glycol stimulated higher production and better orientation of collagen type I in the acute phase of inflammation and tissue repair, and better orientation of collagen fibers in the chronic phase of this process. / As aderências peritoniais possuem grande importância na prática clínico-cirúrgica pela possibilidade de causarem sequelas como dor abdominal crônica, infertilidade e obstrução intestinal, portanto a prevenção do desenvolvimento deste processo torna-se um desafio para os cirurgiões. Devido às propriedades de biocompatibilidade, bioabsorção, cicatrizante e antimicrobiana, a quitosana é um polímero que tem despertado interesse no estudo da prevenção de aderências peritoniais. O objetivo com esta pesquisa foi verificar se o implante intraperitonial de telas de polipropileno revestidas com o filme de quitosana/polietilenoglicol é eficiente na prevenção de aderências em ratos com defeitos abdominais induzidos, além de caracterizar as reações teciduais nas fases aguda e crônica do processo de inflamação e reparo tecidual desencadeadas por este biomaterial, e a tela de polipropileno sem revestimento. Foram realizados defeitos na parede abdominal de aproximadamente 1cm, tendo como referência anatômica a aponeurose das fáscias externas dos músculos reto abdominal e oblíquo abdominal externo, seguida da implantação de telas de polipropileno revestidas com quitosana/polietilenoglicol (Grupo QP, n=12) e telas de polipropileno sem revestimento (Grupo PP, n=12). Seis animais de cada grupo foram submetidos à eutanásia aos quatro e 45 dias após o implante, e foram avaliadas a área de envolvimento da tela pela aderência, o tipo de aderência, o processo de inflamação e reparo tecidual, além da quantificação e tipificação de fibras colágenas. A média das telas envolvidas pelas aderências no grupo QP foi de 39,088% e de 84,024% no grupo PP e a estrutura abdominal envolvida nas aderências no grupo QP geralmente consistiam pelo omento ao redor do implante, no grupo PP, as aderências geralmente estavam na superfície da tela. Após quatro dias do procedimento cirúrgico, a quantidade de células mononucleares foi menor no grupo QP, porém a quantidade de células polimorfonucleares, fibrina e fibras colágenas estavam em maior quantidade nesse grupo, além desta última variável apresentar melhor organização espacial. Após 45 dias da implantação dos biomateriais, houve a redução na quantidade de células inflamatórias, e a organização espacial das fibras colágenas no grupo QP foi permaneceu acentuada. Conclui-se que as telas revestidas com o filme à base de quitosana/polietilenoglicol não preveniram a formação de aderências, porém minimizaram significativamente a gravidade deste processo. Na fase aguda do processo de inflamação e reparo tecidual, a reação de corpo estranho foi menos intensa no grupo que recebeu a tela de polipropileno com revestimento, porém as reações teciduais provocadas pelos biomateriais analisados foram similares na fase crônica. A tela revestida com o filme a base de quitosana/polietilenoglicol estimulou a maior produção e melhor orientação de fibras colágenas tipo I na fase aguda do processo de inflamação e reparação tecidual, e melhor orientação de fibras colágenas na fase crônica deste processo.
4

[en] AUTOMATED SYSTEM FOR MAPPING FERROMAGNETIC FOREIGN BODIES USING GMI MAGNETOMETER / [pt] SISTEMA AUTOMATIZADO PARA MAPEAMENTO DE CORPOS ESTRANHOS FERROMAGNÉTICOS UTILIZANDO MAGNETÔMETRO GMI

BRYAN RODRIGUES CUPELLO DE OLIVEIRA 01 February 2021 (has links)
[pt] A informação sobre o posicionamento de objetos estranhos no interior do corpo humano é essencial para a sua eficiente remoção cirúrgica. Entretanto, os métodos convencionalmente utilizados não fornecem informação suficiente sobre a localização do objeto metálico para garantia de sucesso cirúrgico. No presente trabalho foi desenvolvido um sistema automatizado para mapear a densidade de fluxo magnético estático produzido por corpos ferromagnéticos posicionados em variados graus de liberdade 3D, utilizando um sensor de baixo custo, baseado no fenômeno da magnetoimpedância gigante (GMI - Giant Magnetoimpedance), que detecta somente campos magnéticos variantes no tempo. Assim, as medições automatizadas foram realizadas com a amostra em movimento a uma velocidade constante. Por meio de modelagens computacionais do campo magnético gerado foi possível reproduzir o comportamento da densidade de fluxo magnético gerado por uma fonte de campo magnético como a agulha retilínea utilizada nas medições in vitro. O software considerou as características do sensor GMI utilizado e a condição de medição com a fonte magnética em movimento. Os resultados da simulação foram validados por meio de comparações com os resultados experimentais, possibilitando a solução do problema direto com a caracterização da configuração espacial da densidade de fluxo magnético para variados posicionamentos da fonte magnética em relação ao sensor magnético GMI. Com a validação dos resultados simulados, os mesmos podem ser empregados no desenvolvimento de procedimento para solução do problema inverso de imageamentos clínicos utilizando o sensor GMI de baixo custo, limitado a medições magnéticas variantes no tempo, realizados para detecção e posicionamento de corpos estranhos que geram campos magnéticos estáticos. / [en] Information about the positioning of foreign objects inside the human body is essential for its efficient surgical removal. However, the methods conventionally used do not provide sufficient information on the location of the metallic object to guarantee surgical success. In the present work, an automated system was developed to map the static magnetic flux density produced by ferromagnetic bodies positioned in varying degrees of 3D freedom, using a low-cost sensor based on the giant magnetoimpedance phenomenon (GMI - Giant Magnetoimpedance), which detects only time-varying magnetic fields. Thus, automated measurements were performed with the sample moving at a constant speed. Through computational modeling of the generated magnetic field, it was possible to reproduce the behavior of the magnetic flux density generated by a magnetic field source, such as the straight needle used in in vitro measurements. The software considered the GMI sensor s characteristics and the measurement condition with the magnetic source in motion. The simulation results were validated through comparisons with the experimental results, enabling the solution of the direct problem with the characterization of the spatial configuration of the magnetic flux density for various magnetic source positions in relation to the GMI magnetic sensor. With the validation of the simulated results, they can be used in the development of a procedure to solve the inverse problem of clinical imaging using the low-cost GMI sensor, limited to time-varying magnetic measurements, performed for the detection and positioning of foreign bodies that generate static magnetic fields.

Page generated in 0.0578 seconds