• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 752
  • 34
  • 12
  • 7
  • 7
  • 7
  • 7
  • 5
  • 2
  • 1
  • 1
  • Tagged with
  • 809
  • 406
  • 221
  • 198
  • 194
  • 187
  • 139
  • 109
  • 108
  • 107
  • 107
  • 104
  • 97
  • 89
  • 83
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
351

Análise da penetração de umidade em para-raios poliméricos de distribuição / Analysis of moisture ingress into polymeric surge arresters used in distribution energy systems

Silva, Daiana Antonio da, 1987- 20 August 2018 (has links)
Orientador: José Pissolato Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-20T15:35:10Z (GMT). No. of bitstreams: 1 Silva_DaianaAntonioda_M.pdf: 4722111 bytes, checksum: 375d62ec89d5043ee6edb2f08c980d9d (MD5) Previous issue date: 2012 / Resumo: Sistemas de energia elétrica estão constantemente sujeitos à sobretensões classificadas como internas, decorrentes de operações de manobras e chaveamento no próprio sistema; ou sobretensões decorrentes de agentes externos, por exemplo, descargas atmosféricas. Em ambas as situações, para-raios de óxido de zinco (ZnO) tem sido uma solução eficaz, tanto para os transitórios lentos e oscilatórios quanto para os transitórios rápidos e impulsivos. A utilização de para-raios de óxido de zinco com invólucro polimérico nesses casos é relativamente recente, recorrendo a meados dos anos 80. As informações sobre o desempenho elétrico desses dispositivos ao longo de anos de uso ou quando submetidos a condições críticas de operação são escassas e pouco difundidas na literatura técnica disponível. Dessa forma, uma análise criteriosa é proposta para avaliar o desempenho elétrico de para-raios com invólucro de silicone utilizados nos sistemas de distribuição de energia elétrica, em função da degradação físico-química dos mesmos. São realizados, então, 3 meses de ensaio de imersão/envelhecimento das amostras em água com cloreto de sódio à temperatura de 90 °C, visando representar 20 anos de aplicação do dispositivo em campo. A avaliação do desempenho elétrico é realizada através de medições periódicas da corrente de fuga e da tensão residual, enquanto a avaliação físico-química é obtida através da qualificação do invólucro de silicone utilizado nos para-raios por meio da classificação do grau de hidrofobicidade / Abstract: Electric power systems are constantly subjected to internal overvoltages, i.e. resulting from switching and mechanical operations in the system, or then overvoltages resulting from external causes, e.g. atmospheric surges. In both situations, metal-oxide surge arresters have been an efficacious solution for fast and impulsive electromagnetic transients as well as for slow and oscillatory transients. The use of polymeric metal oxide surge arresters, against atmospheric surges as well as for switching operations, is a relatively recent, dating back to the 1980s. However, the information on the electrical performance of these devices throughout the years of use, or when submitted to critical conditions of operation, is scarce and poorly discussed in the available technical literature. Thus, a thorough analysis is proposed to evaluate the electrical performance of surge arresters with silicone housing, commonly applied in the distribution network, as a function of their physical-chemical degradation. In order to represent 20 years of the field device, 3 months of immersion test/aging in water with sodium chloride at a temperature of 90 degrees will be performed. The evaluation will be through periodic measurements of the leakage current and residual voltage. Another objective is to describe the silicone housing used in surge arresters for classifying the degree of hydrophobicity / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
352

Um modelo de pre-despacho com gerenciamento de congestionamento no sistema de transmissão

Lala, Jose Antonio Oscullo 01 August 2018 (has links)
Orientador : Takaaki Ohishi / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-01T04:12:43Z (GMT). No. of bitstreams: 1 Lala_JoseAntonioOscullo_M.pdf: 1378975 bytes, checksum: 8a172c0b6910bfd1166a96d67780f39a (MD5) Previous issue date: 2002 / Mestrado
353

Retificadores monofasicos com alto fator de potencia e comutação em baixa frequencia

Martins, Eduardo da Silva 01 August 2018 (has links)
Orientador : Jose Antenor Pomilio / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-01T09:34:05Z (GMT). No. of bitstreams: 1 Martins_EduardodaSilva_M.pdf: 2672040 bytes, checksum: 556122abdbcc4a8aebbc625741a327e2 (MD5) Previous issue date: 2002 / Mestrado
354

Desenvolvimento de um sistema inteligente hibrido para diagnostico de falhas em motores de indução trifasicos

Brito, Jorge Nei 21 February 2002 (has links)
Orientador : Robson Pederiva / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-01T20:06:40Z (GMT). No. of bitstreams: 1 Brito_JorgeNei_D.pdf: 32031601 bytes, checksum: c403cff9dbce2d25bcb69ef4c13e55b7 (MD5) Previous issue date: 2002 / Resumo: A aplicação de motores elétricos na indústria é extensa, sendo expostos a uma ampla variedade de ambientes e condições, onde o tempo de uso os tomam sujeitos à diversas falhas incipientes. Tais falhas, se não forem detectadas rapidamente, contribuem para a degradação e eventual quebra dos mesmos. Neste trabalho apresenta-se o sistema híbrido HY_NES, uma abordagem baseada em técnicas de inteligência artificial (redes neurais artificiais e sistemas especialistas) para diagnosticar falhas de origem mecânica (desbalanceamento, desalinhamento e folga mecânica), elétrica (desequilíbrio de fase e barras quebradas) e a condição normal de funcionamento do motor (assinatura da máquina). Os sinais de vibração foram coletados, aleatoriamente, nas direções vertical, axial e horizontal, lado do acoplamento e lado da ventoinha, formando um banco de dados de 50 testes para cada condição de falha. Um filtro seletivo foi aplicado para reduzir o número de parâmetros representativos dos sinais das excitações durante o treinamento das 72 redes neurais artificiais. Foram implementadas 199 regras no sistema especialista que contemplam o conteúdo heurístico para a saída dessas redes. Os resultados do sistema híbrido HY_NES confirmam sua eficiência e o credencia como uma abordagem promissora no diagnóstico on-line de falhas em motores de indução trifásicos, podendo também ser incluído em programas de Manutenção Centrada em Confiabilidade / Abstract: The use of electric motors in industry is extensive. These motors are exposed to wide variety of environments and conditions which age the motor and make it subject to incipient faults. These incipient faults, if left undetected, contribute to the degradation and eventual failure of the motors. This investigation introduces the HY_NES, a new approach behind a novel hybrid neural/expert system technology to solve fault detection from mechanical (unbalance, misalignment and mechanical looseness) and electrical (phase unbalances and broken bars) sources beyond the normal condition (motor signature). Those excitations were obtained through experimental tests repeated fifty times randomly for the same conditions for each condition of failure. The signals were acquired in the both sides of the motor on the vertical, horizontal and axial directions. It will be also employed a selective filter used to reduce the number of parameters to represent the signals of excitations during the 72 artificial neural networks training. It was implemented 199 roles in the expert system that can easily provide heuristics reasoning for the artificial neural network outputs. The results obtained confirmed the efficiency of the hybrid system HY_NES and its relevance as a promising approach to diagnose faults in induction motors on-line as well as inc1uded it in Reliability Based Maintenance programs / Doutorado / Mecanica dos Sólidos e Projeto Mecanico / Doutor em Engenharia Mecânica
355

Teoria de sistemas vibratorios aporticados não-lineares e não-ideais

Palacios Felix, Jorge Luis 03 August 2018 (has links)
Orientadores : Jose Manoel Balthazar, João Maurício Rosário / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-03T02:53:26Z (GMT). No. of bitstreams: 1 PalaciosFelix_JorgeLuis_D.pdf: 10005676 bytes, checksum: 18891d1bfc654d2a094a3bbd0b7857aa (MD5) Previous issue date: 2002 / Resumo: Apresenta-se o estudo do comportamento dinâmico não linear de um pórtico plano, excitado por uma fonte não ideal - um motor elétrico de corrente contínua, desbalanceado e de potência limitada. Toma-se, um problema cujo modelo matemático representa um sistema simplificado (com característica do motor em regime estacionário) e completo (considera-se a equação elétrica do motor). Adota-se a formulação Lagrangeana para gerar as equações de movimento, contendo termos não lineares até ordem cúbica. Tomam-se os valores dos parâmetros, tais que se observa à existência de ressonância interna 1 :2. A solução numérica é obtida através da utilização do método de Runge-Kutta com passo variável do programa MATLAB@. Os resultados numéricos e analíticos mostram boa correlação entre si, além de apresentarem alguns dos fenômenos associados, observados, como o efeito Sommerfeld. Outros fenômenos, devidos ao comportamento geometricamente não linear da estrutura, são também detectados, tais como saturação modal, a transferência de energia entre os modos e, além destes, é detectado a autosincronização entre dois motores apoiados em uma estrutura aporticada. A implementação e desempenho da técnica de controle por saturação para a supressão de vibrações de um sistema ideal e não ideal é estudada numericamente via SIMULINK@ / Abstract: This work concerns the computational and analytical study of the non-linear dynamic behavior of a portal frame, excited by a non-ideal source - an unbalanced direct current electric motor of limited power. A problem whose mathematical model represents a simplified system (the characteristic of the motor in stationary state) and complete (the electric equation of the motor is considered). Lagrange formularization for deducing the equations of motion, up to cubic nonlinear terms is followed. The values of the parameters are chosen to have one-to-two internal Resonance. The numerical solution is obtained through the use of the method of Runge-Kutta with variable step length by MATLAB@. The numerical and analytical results show good correlation, besides presenting some of the phenomena associated, observed, such as the Sommerfeld effect. Other phenomena, due to the geometric non-linear behavior of the structure, are also detected, such as modal saturation and energy transference between the modes. The self-synchronization phenomenon is a1so studied when two DC motors are considered. The implementation and performance of the saturation control for the suppression of vibrations of an ideal and non-ideal system is numerical studied by SIMULINK@ / Doutorado / Mecanica dos Sólidos e Projeto Mecanico / Doutor em Engenharia Mecânica
356

Variabilidade da Corrente Norte do Brasil associada aos padrões termohalinos na borda da Plataforma Continental Norte do Brasil

NOGUEIRA NETO, Antonio Vasconcelos 31 January 2013 (has links)
Submitted by Amanda Silva (amanda.osilva2@ufpe.br) on 2015-03-05T12:25:54Z No. of bitstreams: 2 Dissertaçao Antonio Nogueira Neto.pdf: 8063802 bytes, checksum: 69353f69d12cfe083f907952ab61afc5 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) / Made available in DSpace on 2015-03-05T12:25:54Z (GMT). No. of bitstreams: 2 Dissertaçao Antonio Nogueira Neto.pdf: 8063802 bytes, checksum: 69353f69d12cfe083f907952ab61afc5 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Previous issue date: 2013 / Nas últimas décadas, diversos estudos têm utilizado dados de fontes remotas, in situ e/ou modelos matemáticos para descrever processos importantes da circulação oceânica. Na borda Oeste do Oceano Atlântico Equatorial, a concatenação de informações obtidas por dados de fontes distintas permite um melhor esclarecimento da complexa circulação oceânica nesta área. O presente estudo utiliza dados hidrográficos coletados em três campanhas oceanográficas do Programa REVIZEE ao longo da Plataforma Continental Norte do Brasil (PCNB), realizadas em outubro a novembro de 1997; maio a junho de 1999 e julho a agosto de 2001, bem como uma série de 14 anos (janeiro de 1998 a dezembro de 2011) de coleta de dados mensais de Temperatura da Superfície do Mar – TSM, obtidas por meio do satélite Tropical Rainfall Measuring Mission-Microwave Image (TRMM-TMI), como também os resultados do modelo numérico ATL6. Os dados in situ de temperatura, salinidade e corrente foram coletados através de CTD Sea-Bird, modelo SBE9 e perfilador ADCP modelo RDI Broad Band 75kHz, respectivamente. As duas primeiras variáveis, também foram utilizadas para aplicação do método para cálculo da Mudança de Temperatura Acumulada (MTA), para inferir um possível desprendimento de água da camada de fundo da plataforma, associado ao fluxo da Corrente Norte do Brasil (CNB), próximo à quebra da plataforma. Os resultados in situ e numéricos evidenciam a forte presença da CNB junto à quebra da PCNB, com valores em torno de 1,2m.s-1 no núcleo da corrente (~100m de profundidade) para o período de intensificação da mesma (agosto de 2001). A assinatura do núcleo da corrente é notada até aproximadamente 200m de profundidade, tendendo ficar mais intenso e estável enquanto segue para noroeste da foz do rio Amazonas. Os resultados de modelo mostram que em maio a CNB mantém suas principais características do fluxo (direção noroeste e profundidade), porém é bem menos intensa junto à PCNB (~0,6m.s-1). A distribuição de TSM obtida por CTD, assim como as médias mensais obtidas pelo satélite mostram que, no período de julho a setembro, águas relativamente mais frias (<27.5°C) chegam à região através da CNB. Os resultados de TSM do modelo mostram essas mesmas características, mas os valores de temperatura são subestimados pelo mesmo com diferenças em torno 2°C das obtidas porsatélite. Os transectos de temperatura para o mesmo período mostram que toda a camada acima da termoclina apresenta queda nas temperaturas junto à PCNB. Já no período de menor intensidade da CNB e maior descarga do rio Amazonas (maio de 1999) foram observadas águas mais quentes (>28°C) na região, estando associadas ao posicionamento próximo ao Equador da Zona de Convergência Intertropical e presença da pluma de baixa salinidade do rio Amazonas. Os resultados obtidos na distribuição da MTA demonstraram um possível desprendimento de água da camada de fundo da PCNB próximo à isopicna de 23.7kg.m-3, no período compreendido entre julho a agosto de 2001 e outubro a novembro de 1997, sendo que no período de maio a junho de 1999, características de desprendimento são observadas próximo à isopicna de 23kg.m-3. Tais variações na distribuição de MTA apresentaram semelhanças a sudeste e a noroeste da foz do rio Amazonas, em função da presença ou ausência da pluma. Entretanto, os dados indicam que estas características estão relacionadas à CNB, porém independem das variações sazonais da mesma. Os resultados apresentados neste estudo mostram que a CNB contribui para as alterações de temperatura da coluna d’água sobre a termoclina ao longo da PCNB, mas estas alterações estão possivelmente ligadas à sazonalidade da pluma do rio Amazonas sobre a PCNB.
357

[en] SERIES LIMITING CURRENT REACTOR FOR ARC FURNACES / [pt] REATOR SÉRIE LIMITADOR DE CORRENTE PARA FORNOS A ARCO

SERGIO CORDEIRO SOBRAL 29 December 2006 (has links)
[pt] Esta tese apresenta os principais fenômenos eletromecânicos, que ocorrem durante a operação do forno a arco, com ênfase especial nos fenômenos elétricos e magnéticos envolvidos. Apresenta também uma simulação computacional, que tem por objetivo verificar que a utilização de um reator série limitador de corrente no circuito de alimentação do forno, visando estabilizar o arco, não reduz significativamente a potência operacional do mesmo à 60Hz. A tese apresenta ainda os resultados de uma simulação analógica, que permite verificar que a impedância do reator série limitador, vista pelo circuito do forno, é pequena à 60 Hz e relativamente elevada em outras freqüências. Desta forma, tem-se um efetivo amortecimento das flutuações de corrente e tensão, causadas pela operação do forno, sem restringir a potência operacional do mesmo. / [en] This thesis presents the main electromechanical phenomena, occuring during the operating of an arc furnace, focusing the electric and magnetic ones. It also presents a digital simulation aiming to verify that the utilization of a series limiting current reactor included into the furnace feeding circuit, for arc stabilization purposes, does not reduce its operational capacity at 60 Hz. It is also presented the results of an analogic simulation, which shows that the reactor impedance seen by the furnace circuit is small at 60 Hz and relatively large at other frequencies. Hence, an effective damping of the current and voltage variations, caused by the furnace operation, can be achieved.
358

[pt] DESENVOLVIMENTO DE UMA PONTE PARA CALIBRAÇÃO DE RESISTORES EM CORRENTE ALTERNADA

PETRONIO BERQUO 04 April 2002 (has links)
[pt] Esta Dissertação de Mestrado apresenta o desenvolvimento de uma nova ponte de medição para a calibração de resistores padrão de corrente alternada.O circuito equivalente de resistores em corrente alternada foi apresentado e analisado, parâmetros para caracterizar o resistor foram definidos.Em seguida, métodos e construções para minimizar as impedâncias espúrias de resistores padrão de corrente alternada foram apresentados e as soluções mais importantes foram detalhadas. A teoria e a construção de resistores calculáveis e sua utilização como padrão de constante de tempo foi resumida. Vários tipos foram descritos e o projeto de desenvolvimento de um resistor calculável foi detalhado.Várias pontes de medição para essa finalidade, desenvolvidas por laboratórios primários, foram apresentadas e analisadas, em especial a ponte desenvolvida por Ramm no PTB. Essa análise foi importante para dar orientação ao desenvolvimento da nova ponte. Para se chegar à nova ponte, os circuitos fundamentais foram mostrados e passo a passo foram acrescentados, levando em conta os componentes e recursos existentes no Laboratório.Por causa da falta de diversos componentes, como divisores indutivos especiais, geralmente usados em outras pontes, foi necessário aceitar compromissos e, apesar das limitações, tentar realizar o melhor possível desempenho da nova ponte. Por último, a exatidão da nova ponte foi verificada e a medição da constante de tempo foi calibrada. A exatidão e as incertezas foram especificadas.
359

Parametros longitudinais e transversais de linhas de transmissão calculados a partir das correntes e tensões de fase

Kurokawa, Sergio 03 August 2018 (has links)
Orientadores : Jose Pissolato Filho, Maria Cristina Dias Tavares / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-03T15:13:05Z (GMT). No. of bitstreams: 1 Kurokawa_Sergio_D.pdf: 1272093 bytes, checksum: aa03df351ad2dc310184019293aa31f4 (MD5) Previous issue date: 2003 / Doutorado
360

Uma contribuição ao estudo da influencia de elos CC na dinamica de sistemas CA, atraves de simulação digital

Souza, Julio Borges de 07 May 1986 (has links)
Orientadores: Jose Carlos de Oliveira , Andre Luis Morelato França / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica / Made available in DSpace on 2018-07-16T20:19:14Z (GMT). No. of bitstreams: 1 Souza_JulioBorgesde_M.pdf: 10517790 bytes, checksum: 28915bef80eebb6a54947c1595e0777f (MD5) Previous issue date: 1986 / Resumo: Este trabalho tem objetivo o estudo da influência de elos CC na dinâmica de sistemas CA. Para tanto são pesquisados e implementados vários modelos visando a modulação da potência ativa transmitida pelo elo e também a modulação do ângulo de extinção da inversora. E também investigado o efeito da reatância de comutação das conversoras e sobre o cálculo das potências requeridas pelas mesmas. Casos práticos são simulados, analisados e discutidos. concluindo-se a respeito da eficiência das modelagens apresentadas e conseqüente efeito sobre o amortecimento das oscilações e controle de freqüência / Abstract: This work aims to study the effeet of HVDC systems upon the dynamie of AC systems. In this way, several models which use de power modulation an extinction angle control are considered and included into a digital transient stability programme. Apart from this, the effect or the AC system eommutation reactanee on the active and reactive AC power calculations is investigated using a digital computer programme. Practical studies are then carried out and the corresponding results are analised so to conclude about the required damping introduced by the functions included on the oscillations and frequency control / Mestrado / Mestre em Engenharia Elétrica

Page generated in 0.0544 seconds