• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1392
  • 17
  • 16
  • 15
  • 15
  • 15
  • 7
  • 7
  • 7
  • 4
  • 4
  • 4
  • 3
  • 1
  • 1
  • Tagged with
  • 1431
  • 690
  • 469
  • 306
  • 241
  • 205
  • 197
  • 185
  • 166
  • 158
  • 122
  • 121
  • 116
  • 108
  • 105
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
861

Desenvolvimento do processo friction stir welding para a liga Inconel 625

Lemos, Guilherme Vieira Braga January 2017 (has links)
As ligas a base de Níquel são frequentemente utilizadas na indústria do petróleo devido à elevada resistência mecânica e excelente resistência à corrosão. Neste cenário, a utilização da soldagem como etapa na fabricação de dutos rígidos de grande comprimento é inevitável. Assim, chapas da liga Inconel 625® foram unidas através do processo Friction Stir Welding (FSW). A soldagem foi executada com uma ferramenta de nitreto cúbico de boro policristalino e o inerente desta ferramenta foi analisado. Em um primeiro momento, na seleção de parâmetros de processo, diversas condições de processo foram analisadas para escolha da melhor solda. Após esta etapa, novas juntas soldadas foram produzidas com o parâmetro de processo adequado (velocidade de rotação da ferramenta de 200 rpm e velocidade de avanço de 1 mm/s). A caracterização da superfície de topo da solda foi realizada através da microscopia ótica, microscopia eletrônica de varredura, microdureza e ensaios de dobramento. Defeitos superficiais foram inspecionados com líquidos penetrantes. Além disso, os estados de tensões residuais foram obtidos com a difração de raios-X. Ainda, a resistência à corrosão localizada foi estudada com o ensaio de imersão em cloreto férrico e a determinação da temperatura crítica de pite (conhecida como CPT) Por fim, a susceptibilidade à corrosão intergranular foi avaliada com o ensaio Streicher Test. O processo de soldagem promoveu o refino de grão e o aumento de dureza na solda. As micrografias do metal de base (MB) mostraram carbonetos do tipo MC, M6C, M23C6. Por outro lado, a melhor junta soldada apresentou uma microestrutura livre de defeitos, homogênea, onde não foram percebidos carbonetos do tipo M6C, M23C6 nos contornos de grão, foi aprovada nos ensaios de dobramento, líquidos penetrantes e imersão em FeCl3. Entretanto, ocorreu o um desgaste da ferramenta, mas reduzido e aceitável para esta solda. Tensões residuais longitudinais trativas da ordem de 50 MPa foram observadas na zona de mistura. Considerando o valor médio, o MB alcançou uma CPT de 77 °C, enquanto no centro da solda a CPT foi de 86°C. A taxa de corrosão média alcançada após o ensaio de corrosão intergranular foi de 0,4406 mm/ano, valor que sugere uma boa qualidade da solda. / Nickel based alloys are often used in the oil and gas industry due to their great mechanical strenght as well as excelent corrosion resistance. In this scenario, welding as manufacturing step for long lenght rigid tubes is inevitable. Therefore, Inconel 625® sheets were joined by Friction Stir Welding (FSW). The welding was performed with a Polycrystalline Cubic Boron Nitride (pcBN) tool and the unavoidable tool wear was verified. At first, in the process parameter development step, different process conditions were analyzed for choosing the best welded joint. Afterwards, new welded joints were produced with the suitable process parameter (tool rotational speed of 200 rpm and welding speed of 1 mm/s). Top surface characterization of friction-stir-welded Inconel 625 was carried out by optical microscopy, scanning electron microscopy, microhardness and bending tests. Surface defects were verified by dye penetrant inspection (DPI). In addition, residual stress states were obtained by X-ray diffraction. Furthermore, localized corrosion resistance was studied by the immersion test in FeCl3 and the critical pitting temperature (CPT) determination. Finally, the susceptibility to intergranular corrosion was evaluated by Streicher Test. FSW process promoted grain refining as well as increased microhardness in the joint Base material micrographs showed different carbides as MC, M6C, M23C6. On the other hand, the best joint presented a sounds weld without defetcs, homogeneous microstructure, grain boundaries free of M6C, M23C6 carbides, approved in bending tests, DPI and the immersion test. However, a tool wear was also noted, but reduced and acceptable for this weld. Tensile longitudinal residual stresses of 50 MPa were observed in the stir zone. As an avarage, the base material CPT was 77 °C, while the CPT was 86 °C at the weld center. The mean corrosion rate after intergranular corrosion test was 0.4406 mm/year, a value which suggests a good weld quality.
862

Resistência à corrosão do aço inoxidável AISI 304 com implantação de íons de cobre

Canabarro, Felipe Ariel Furlan January 2018 (has links)
O efeito bactericida de íons cobre é bem conhecido; no entanto a atividade inibitória depende diretamente da concentração desses íons no material base. Contudo, essa concentração deve ser controlada, pois o excesso destes íons pode ser tóxico e além disso, a implantação de cobre pode comprometer a resistência a corrosão do substrato metálico. A propriedade bactericida é desejável para aplicação em ligas metálicas empregadas em diversos setores, na assepsia de materiais que tenham contato direto com subprodutos que necessitam alta pureza e com baixíssimos índices de contaminação. O aço inoxidável austenítico AISI 304 é amplamente utilizado devido às suas propriedades mecânicas e de resistência à corrosão. Considerando isso, o aço AISI 304 é o foco do presente estudo, mesclando as características anticorrosivas naturais com a assepsia oligodinâmica proveniente da dopagem com íons de cobre. Nesse sentido, avaliou a resistência à corrosão do aço inoxidável AISI 304 com diferentes doses de cobre implantado (1015 íons.cm-2 e 1016 íons.cm-2) por monitoramento do potencial de circuito aberto e voltametria cíclica em uma solução eletrolítica de NaCl 3,5 % em peso. Através de simulações computacionais, previu-se que nos parâmetros escolhidos, a profundidade de implantação dos íons no substrato atingiu até 40 nm da superfície, com uma concentração de pico, maior teor de cobre, na profundidade de 12 nm. As amostras com doses de 1015 íons.cm-2 de cobre apresentaram o potencial de pites semelhante ao aço inoxidável austenítico AISI 304 sem implantação de Cu. Na análise de EDS observou-se que as áreas que não sofreram corrosão, apresentaram melhor distribuição dos elementos de liga e do cobre implantado em comparação com as regiões com maior incidência de pites. A maior intensidade de pites foi encontrada para a amostra com maior dose de cobre implantado (1016 íons.cm-2 de cobre). / The bactericidal effect of copper ions is well known; however, the inhibitory activity depends directly on the concentration of these ions in the base material. However, this concentration should be controlled because the excess of these ions can be toxic and the implantation of copper may compromise the corrosion resistance of the metal substrate. The bactericidal property is desirable for application in metal alloys used in the several sectors, in the asepsis of materials that have direct contact with by-products that require high purity and with very low contamination rates. The AISI 304 austenitic stainless steel is widely used because of its mechanical properties and corrosion resistance. Considering this, the AISI 304 is the focus of the present study, mixing the natural anticorrosive characteristics with the oligodynamic aseptic from the copper ions doping. The corrosion resistance of AISI 304 stainless steel with different doses of implanted copper (1015 ions.cm-2 and 1016 ions.cm-2) was evaluated by monitoring the open circuit potential and cyclic voltammetry in an electrolytic solution of NaCl 3,5% by weight. Through computational simulations, it was predicted that in the chosen parameters, the implantation depth of the ions in the substrate reached up to 40 nm from the surface, with a peak concentration, higher copper content, at the depth of 12 nm. The samples with doses of 1015 ions.cm-2 of copper had the pit potential similar to the austenitic stainless steel AISI 304 without implantation of Cu. In EDS analysis, it was observed that the areas that did not undergo corrosion had better distribution of the alloying elements and of the implanted copper compared to the regions with a higher incidence of pitting. The highest pitting intensity was found for the sample with the highest dose of implanted copper (1016 ions.cm-2 copper).
863

Avaliação do comportamento corrosivo de aços galvanizados utilizando microssondas eletroquímicas

Manhabosco, Sara Matte January 2017 (has links)
Revestimentos de zinco obtidos por imersão a quente têm sido amplamente utilizados em estruturas expostas em solos, águas naturais e atmosfericamente, devido a excelente resistência em meios de baixa agressividade. Nessas aplicações, as arestas de corte ficam expostas e estão mais susceptíveis à corrosão. Objetivando relacionar a microestrutura dos revestimentos com técnicas de microssondas eletroquímicas, para melhor entender os processos corrosivos de aços galvanizados, buscou-se uma nova metodologia para ampliar as fases e obter uma estrutura em camadas. Para a caracterização da morfologia dos revestimentos obtidos pelo processo de galvanização por imersão a quente (galvanized, galvannealed e galvalume) utilizou-se microscopia óptica e eletrônica de varredura com microanálise. Para verificar e analisar os mecanismos de corrosão das fases presentes nos revestimentos de zinco de forma localizada empregou-se a técnica de varredura por eletrodo vibratório (SVET) e microcélula capilar (MEC), e de forma complementar, para identificar os produtos de corrosão formados utilizou-se micro difração de raios X (μ-DRX). Os resultados demonstraram que a metodologia empregada neste estudo é adequada para avaliar as fases de forma individual ou conectadas galvanicamente, e assim identificar as fases mais ativas durante os processos corrosivos. Os resultados obtidos por microcélula complementam os mapeamentos de densidade de corrente obtidos por eletrodo vibratório, mostrando que os intermetálicos permanecem estáveis após os ensaios e a região mais ativa é o revestimento não intemperizado (polido) próximo à interface aço/revestimento. O revestimento que apresentou melhor resistência à corrosão em soluções contendo cloreto foi o Zn55Al. O espectro μ-XRD para o revestimento galvanized, indica a presença das fases zincita e Fe-α sobre o aço IF (interstitial free), mostrando que sob condições de OCP a superfície de aço IF foi protegida pelo revestimento apesar da sua grande área. Esta precipitação pode ainda proteger áreas de aço expostas aonde o revestimento foi danificado por arranhões ou na aresta de corte. / Hot-dip zinc coatings have been widely used in structures exposed to soils, natural water and atmosphere due to their excellent resistance in low aggressive media. In such applications, the cutting edges are exposed and more susceptible to corrosion. In order to correlate the microstructure of the coating with electrochemical microprobe techniques, a new methodology was developed to amplify the size of the phases and to obtain a layered structure. Optical microscopy and scanning electron microscopy were used to characterize the morphology of the coatings obtained by the hot dip galvanization process (galvanized, galvannealed e galvalume). Scanning vibrating electrode technique (SVET) and capillary microcell (MEC) were used to identify and study the corrosion mechanisms of the phases present in zinc coatings. The corrosion products were identified by X-ray micro-diffraction (μ-XRD). The results demonstrated that the methodology employed in this study is adequate to evaluate the phases individually or galvanically connected, thus identifying the most active phases during the corrosive processes. The results obtained by microcell complement the current density mappings obtained by vibrating electrode, showing that the intermetallics remain stable after the analysis and the most active region is the not wedered coating near the steel/coating interface. The coating that showed the best corrosion resistance in solutions containing chloride was the Zn55Al. The μ-XRD spectrum for the galvanized coating indicates the presence of zincite and Fe-α on the IF steel (interstitial free), showing that under OCP conditions the IF steel surface was protected by the coating despite its large area. This precipitation can further protect exposed steel areas where the coating has been damaged by scratches or at the cutting edge.
864

Efeito da conformação mecânica na resistência a corrosão dos aços NBR7008 ZC/Z275 e Galvalume® ASTM A792 CSB/AZM150

Américo, Renato January 2016 (has links)
Os materiais usados nas indústrias de fabricação de máquinas para o setor de armazenagem e secagem de grãos, devem garantir o desempenho requerido, não gerando nenhum prejuízo ou descontentamento do cliente final. Esta pesquisa tem como objetivo principal, avaliar o desempenho do aço Galvalume® em relação ao aço Galvanizado NBR7008 quando conformados, quanto a resistência a corrosão de ambos os materiais. Para isso foram executados testes em amostras de chapas lisas e conformadas nos aços mencionados. As amostras foram avaliadas quanto à resistência à corrosão a partir de ensaio em câmara de névoa salina (chapas lisas) e ensaio de imersão (chapas conformadas). Além disso, as amostras foram caracterizadas quanto à espessura e morfologia dos revestimentos por MEV e perfilometria em (chapas conformadas). Também foi realizado o ensaio de envelhecimento em campo, que consistiu em avaliar o aspecto visual com ambas as chapas, montadas na tampa de um silo em uso na área rural. A partir dos resultados obtidos nos ensaios, antes e após a conformação mecânica, ficou evidenciada a influencia do processo de conformação sobre a resistência à corrosão do aço Galvanizado NBR7008. Observou-se que as áreas submetidas com as dobras das laterais tiveram a taxa de corrosão aumentada. O mesmo não ocorreu para o aço revestido com Galvalume®, o qual apresentou menor taxa de corrosão do que o aço Galvanizado NBR7008. Os resultados obtidos no ensaio de envelhecimento evidenciaram a grande diferença em relação ao aspecto visual dos painéis, observando-se no aço Galvanizado uma perda excessiva do brilho, com a escurecimento da chapa após 3 anos de exposição em zona rural. Já as chapas de aço Galvalume® mantiveram o brilho após todo esse período de exposição na mesma atmosfera evidenciando a sua superioridade quanto as intempéries. O custo inicial do aço Galvalume® é, em média, 12% mais elevado que o custo do aço galvanizado (NBR7008 ZC/Z275). Contudo é importante salientar que essas características quanto ao aspecto visual são determinantes para a aceitação dos silos pelos clientes. / The most used materials in the industry of manufacture of machines for the storage and grain drying department must ensure the required performance, and should not causing any loss or dissatisfaction to the final customer. This research has as main goal measuring the performance of Galvalume® steel compared to the Galvanized steel NBR7008, when conformed, evaluating the corrosion resistance of both materials. For that, tests were made on samples of plain steel sheet and conformed steel sheet with the mentioned kinds of steel. The samples were evaluated taking into consideration the corrosion resistance in immersion test (shaped plate) and salt spray test (flat sheet). Besides, the samples were described according to thickness and coating morphology by MEV and perfilometry. Also, a test of accelerated aging was made, which consisted in measuring visual aspect in both kinds of steel. They were assembled on the cover of a silo that was working, located in the countryside. From the results reached through the tests, before and after the mechanical conformation, the influence of conformed process on the corrosion resistance of the Galvanized steel NBR7008 was evidenced. It could be noted that the areas submitted with lateral folds had corrosion rates increased. But, with the Galvalume® steel was different, this one showed lower corrosion rate than Galvanized steel NBR7008. The results reached with the accelerated aging test showed the big difference related to visual aspects of the panels, in which an excessive brightness loss on the Galvanized steel, with the darkening of the steel sheet after 3 years of exposure in the countryside was observed. Whereas the Galvalume® steel sheet kept the brightness after all this period of exposure to the same atmosphere, showing its superiority in corrosion resistance. The cost of Galvalume® steel is about 12% higher than cost of Galvanized steel (NBR7008 ZC/Z275). However it is important to point these attributes, regarding to visual aspect, which are determinants for good acceptance of silos by the customers.
865

Análise comparativa de inibidores de corrosão na água poro e no concreto armado para aço carbono CA-50 / Comparative analysis of corrosion inhibitors in the pore water and in reinforced concrete for carbon steel Ca-50

Ossorio Dominguez, Anile January 2016 (has links)
No presente trabalho analisa-se o comportamento do aço de reforço ante à corrosão, com o uso dos inibidores: nitrito de sódio, fosfato de sódio e etalonamina, na água de poros contaminada com cloreto, e no concreto com a finalidade de analisar seus resultados e seus mecanismos diferenciados. Para cumprir este objetivo o presente trabalho divide-se em duas etapas: uma primeira etapa baseada em simular sinteticamente a água de poro de um concreto, cuja solução é KOH 28g/l+NaOH 4g/l. Essa água de poro é simulada em ambiente marinho, cuja solução é KOH 28g/l + NaOH 4g/l+NaCl 35g/l, e a esta solução referência incorporamse os inibidores (20g/l da cada um). Realizaram-se ensaios de espectroscopia de impedância eletroquímica (EIE) (após 3 e 72 horas de imersão) e curvas de polarização (após 72 horas de imersão) com vistas a obter respostas da cinética da corrosão ante a cada solução. Obteve-se o melhor comportamento para a água de poros. No caso da água de poro contaminada por cloretos, o melhor comportamento se obteve para o inibidor nitrito de sódio. Na segunda etapa adotou-se apenas o inibidor nitrito de sódio, pois estatisticamente as eficiências dos três inibidores foram muito similares. Analisou-se o nitrito de sódio em amostras reais de concreto armado contaminado com cloreto de sódio. Para isso se elegeram dois tipos de cimentos (CP IV e CP V) e três relações água-cimento (a/c-0.4, a/c-0.5, a/c- 0.65). Para simular o ambiente marinho, realizaram-se ensaios acelerados de cloretos. Comparam-se métodos de análises simuladas sinteticamente e reais, concluindo-se em ambos meios, embora fossem um solido e outro líquido o inibidor Nitrito de Sódio aumento a sua eficiência com os ciclos de exposição. / In this paper it is analyzed the behavior of reinforcing steel against corrosion using inhibitors: sodium nitrate, sodium phosphate and ethanolamine in water contaminated with chlorides pore and concrete, in order to analyzing the results and different mechanisms. To meet the objective of this work, it was divided into two stages, a first stage based on synthetically simulate the pore water of a concrete, through the following solution KOH 28g/l+NaOH 4g/l, this same solution simulated pore water to a marine environment it would be KOH 28g/l + NaOH 4g/l+NaCl 35g/l, it is then incorporated into both reference solutions inhibitors in a proportion, (20g/l de cada um). Assays were performed electrochemical impedance spectroscopy (EIE) (last 3 hours and 72 hours of immersion) and polarization curves (last 72 hours of immersion) in order to obtain responses corrosion kinetics in each solution. the best performance was obtained in the pore water. In the case of water contaminated with chlorides pore, the best performance was obtained in the presence of sodium nitrite inhibitor. In the second step was performed only with the inhibitor sodium nitrate, as statistically efficiencies of the three inhibitors were similar. Sodium nitrate was analyzed in real samples of reinforced concrete contaminated with chlorides of sodium. So they were chosen two types of cement CP- IV and CP-V, cement water three relationships 0.4, a/c-0.5, a/c- 0.65. In this case to simulate the marine environment, accelerated tests were performed chloride. They were compared the methods of analysis, simulated synthetically and simulated in real concrete.
866

Estudo de corrosão e de permeação por hidrogênio em ligas com memória de forma CuAlNi.

LIMA, Juliana de Figueiredo. 22 August 2018 (has links)
Submitted by Maria Medeiros (maria.dilva1@ufcg.edu.br) on 2018-08-22T13:32:43Z No. of bitstreams: 1 JULIANA DE FIGUEIREDO LIMA - TESE (PPGEQ) 2018.pdf: 3687514 bytes, checksum: 5500c1ad00c05f03476049218f866f46 (MD5) / Made available in DSpace on 2018-08-22T13:32:43Z (GMT). No. of bitstreams: 1 JULIANA DE FIGUEIREDO LIMA - TESE (PPGEQ) 2018.pdf: 3687514 bytes, checksum: 5500c1ad00c05f03476049218f866f46 (MD5) Previous issue date: 2018-03-02 / Capes / Diante de futuras perspectivas para utilização de ligas com memória de forma (LMF) a base de CuAlNi e devido ao seu baixo custo e relativa facilidade de fabricação, o estudo de corrosão e permeação por hidrogênio nessas ligas é de extrema importância para a comunidade científica e os diferentes setores da indústria. Este trabalho realizou um estudo de corrosão em ligas LMF do tipo CuAlNi e CuAlNi(MnTi) a diferentes temperaturas a partir do seu estado bruto de fusão e tratadas termicamente; foi também investigado a permeação por hidrogênio na LMF CuAlNi comercial e fabricada em laboratório. O estudo de corrosão foi realizado utilizando-se técnicas eletroquímicas de polarização linear para determinação da resistência à polarização (RP), taxa de corrosão (CR) e corrosimetria em diferentes temperaturas e os resultados obtidos foram comparados para as duas ligas utilizadas. Já o estudo de permeação por hidrogênio, foi realizado pelo método galvanostático-potenciostático e a análise dos parâmetros difusividade, solubilidade e fluxo de permeação do hidrogênio na liga CuAlNi, foi realizada em relação as ligas API 5L X60, 80 e ECT P110. A verificação do efeito memória de forma por Calorimetria Diferencial de Varredura (DSC) foi igualmente realizada, bem como os produtos formados pela corrosão na superfície das amostras e composição química utilizando a Microscopia eletrônica de Varredura (MEV) e a Espectroscopia de Energia Dispersiva (EDS), respectivamente. Os resultados mostraram que a taxa de corrosão aumentou com a temperatura para a liga bruta de fusão e tratada termicamente. As ligas tratadas termicamente apresentaram um crescimento contínuo de CR desde o início do ensaio devido ao fato de que o resfriamento rápido a partir de altas temperaturas cria um excesso de vacâncias e tensões na microestrutura que acelera os processos corrosivos. As análises de DSC comprovaram que as amostras apresentaram propriedades de memória de forma. Foi possível comprovar a partir das análises MEV e EDS, os pontos de corrosão e sua composição química respectivamente. Finalmente os resultados de permeação por hidrogênio comprovaram uma maior absorção ou solubilidade nestas ligas quando comparadas com alguns aços da classe API. Indicando à princípio, que estes materiais não são indicados para serem utilizados em ambientes ricos em H2. / In view of the future prospects for the use of CuAl Alloys with shape memory (SMA), and due to its low cost and relative ease of manufacture, the study of corrosion and hydrogen permeation in these alloys is extremely important for the scientific community and the different sectors of the industry. In the first case, its chemical stability is evaluated against corrosive environments, and in the second the susceptibility of damage by the absorbed hydrogen. In this way some limits or expansion of application of these alloys may be known. This work aims to perform a corrosion study on SMA alloys of the CuAlNi and CuAlNi (MnTi) type at different temperatures from their melt state and thermally treated; was also investigated the hydrogen permeation in the CuAlNi LMF. The corrosion study was carried out using linear polarization electrochemical techniques to determine polarization resistance (RP), corrosion rate (CR) and corrosimetry at different temperatures. On the other hand, the hydrogen permeation study by the galvanostatic-potentiostatic method and analysis of the parameters diffusivity, solubility and hydrogen permeation flux in the CuAlNi alloy, was evaluated in relation to API alloys 5L X60, 80 and ECT P110. The SMA properties was evaluated by Differential Scanning Calorimetry (DSC) as well as the verification of the products formed by corrosion was performed using Scanning Electron Microscopy (SEM). The verification of the chemical composition of the alloys was carried out using Dispersive Energy Spectroscopy (DES). The results showed that the corrosion rate increased with the temperature for the raw alloy and heat treated. However it has been found that thermally treated alloys have shown a continuous growth of CR since the start of the test due to the fact that rapid cooling from high temperatures creates an excess of vacancies in the microstructure which accelerates the corrosive processes. The DSC analyzes showed that the samples presented shape memory properties. In addition, it was possible to verify the corrosion points and their chemical composition from the SEM and EDS analyzes. Finally the hydrogen permeation tests were carried out with commercial CuAlNi alloy and prepared in the laboratory. The results showed a higher absorption or solubility of the Hydrogen in these alloys when compared with some API grade steels. This indicates at the outset that these materials are not suitable for use in hydrogen-rich atmospheres.
867

Estudo da corrosão da armadura induzida por carbonatação em concretos com cinza volante / Study of reinforcing steel corrosion inducted by carbonation of concrete with fly ash

Abreu, Aguida Gomes de January 2004 (has links)
Este trabalho apresenta um estudo de corrosão da armadura induzida por carbonatação em concretos com elevados teores de cinza volante, utilizando-se para isso a técnica de resistência de polarização. Selecionou-se para a pesquisa quatro relações água/aglomerante (0,44, 0,48, 0,55 e 0,65) e quatro teores de substituição de cimento (clínquer + gesso) por cinza volante (0,15, 30 e 45%). Foi também escolhido para comparação o cimento CPIV 32. Os corpos-de-prova foram curados por 28 dias, sazonados por 22 dias e então carbonatados em ambientes com 5 e com mais de 50% de CO2, por um período 223 dias. Após, os concretos foram parcialmente imersos durante 35 dias. Os ensaios de resistência de polarização foram feitos durante todo o período de carbonatação e imersão parcial. Paralelamente, romperam-se corpos-de-prova por compressão axial, determinou-se profundidades carbonatadas e monitorou-se as massas dos corpos de prova usados para ensaio de resistência de polarização. Realizou-se também análises complementares de microestrutura, utilizando-se as técnicas de difração por raios-X, fluorescência de raios-X, microscopia eletrônica de varredura por elétrons retroespalhados, análises com EDS (Energy Dispersive Spectroscopy) e espectroscopia Raman. Os experimentos realizados possibilitaram identificar o efeito significativo da variação do teor de cinza volante para a corrosão da armadura. Os resultados assim obtidos também permitiram constatar o efeito significativo do teor de CO2 para os resultados de potencial de corrosão e de densidade de corrente de corrosão. Os resultados obtidos neste trabalho evidenciaram a importância de cada vez mais se buscar a realização de ensaios que reproduzam o máximo possível condições de exposição das estruturas no ambiente. / This work presents a study of corrosion of reinforcing steel induced by carbonation in concretes containing fly ash. Four water-binder ratios (0,44; 0,48; 0,55 and 0,65) and four clinker (clinker + gypsum) replacements of fly ash (0;15; 30 and 45%) were selected. It was also chosen CPIV 32 cement to study. After 28 days kept in the moist curing room, the samples were carbonated during 223 days in a CO2 atmosphere with 5% and more than 50% of CO2 After the carbonation period, the concretes samples were partially immersed during 35 days in potable water. Linear polarization resistance tests were made during the whole carbonation and partial immersion periods. Moreover, compressive strength tests were made, depth of carbonation in concretes were determined and the masses of samples used in linear polarization resistance tests were monitored. Even microstructure complementary analyses were made using X-ray diffraction (DRX) techniques, X-ray fluorescence (FRX), electronic microscopy using backscattered electrons and energy dispersive spectroscopy analyses and Raman spectroscopy. Based on the accomplished tests it’s possible to identify the significant effect of the fly ash level replacement in concrete on the reinforcing steel corrosion. The thus gotten results also had of allowed evidencing the significant effect of the CO2 concentration on the results of corrosion potential and corrosion current density.
868

Avaliação da sensibilidade do CAIM - corrosão acelerada por imersão modificada - frente ao processo de corrosão em armaduras de concreto armado

Torres, Ariela da Silva January 2006 (has links)
A construção civil vem se deparando com uma dualidade que envolve avanços dos métodos de cálculo e tecnologia dos materiais contraposto ao incremento das patologias das construções. Inúmeros levantamentos estatísticos, realizados nos últimos anos, vem demonstrando a grande incidência e repercussão dos processos patológicos atuantes sobre as estruturas de concreto. Vários estudos comprovam que a corrosão de armaduras no concreto é de grande incidência nas construções e, na maioria dos casos, aquele que gera os maiores problemas, tanto em termos de custo como de segurança. Isto explica porque técnicas de medição de resistência à corrosão vêm sendo intensamente estudadas. Todavia, dada a complexidade do assunto e a falta de normalização específica, observa-se a existência de uma grande diversidade de métodos de ensaio, aliada à ausência de uma padronização dos tipos e condições de ensaio. A maioria dos pesquisadores adapta ensaios anteriormente realizados, sem realizar estudos específicos sobre a eficiência e reprodutibilidade dos mesmos. O presente trabalho descreve um estudo realizado com o intuito de avaliar qual os efeitos das variações das condições de ensaio, como tempo de exposição e diferença de potencial induzida, no comportamento de corpos-de-prova de diversas relações água/cimento testados pela metodologia CAIM, um tipo de ensaio acelerado comparativo de corrosão por imersão em solução salina, que já foi empregado em várias pesquisas no LEME. O objetivo é entender como o ensaio reage a variações de método, verificando sua sensibilidade a estas e definindo quais as condições padrão mais adequadas. / The construction community is facing a dualistic reality, where advances in design methods and materials technology are opposed by the increase in pathological problems registered in our structures. Several recent surveys have pointed out that several and important deterioration processes occur in concrete structures. Many studies indicate that reinforcement corrosion is one of the most prevalent and costly between these. That explains why there are so much interest in studying methods to evaluate the corrosion resistance of construction materials. However, given the complexity of the theme and the lack of standardization, a great diversity of methods have evolved, without a proper definition and parameterization of testing conditions. A great number of researches simply adapt methods used by others, not paying enough attention to the evaluation of the efficiency and reproducibility of the test method. This prevents the comparison of results and creates obstacles to sharing data and articulate research efforts. The present work describes a study aimed at evaluating the influence of variations in test conditions, such as exposure time and induce voltage, in the performance of mortar samples with different w/c relations subjected to the CAIM test. This comparative accelerated method, in which mortar samples are immersed on a saline solution and connected to a constant voltage source, has already been used in several studies at LEME. The study analyses how the method respond to variations in test conditions and will help establish the more efficient standard conditions for the test considering the whole range of concrete strengths.
869

Avaliação experimental e modelagem dos efeitos estruturais da propagação da corrosão em elementos de concreto armado

Graeff, Ângela Gaio January 2007 (has links)
O concreto armado era tido, quando da sua concepção inicial, como um material que teria boa durabilidade e uma vida útil elevada, praticamente dispensando reparos. Com a intensificação de seu uso, todavia, começaram a serem observados diversos processos de deterioração que resultaram, nos casos mais críticos, em severos comprometimentos de desempenho ou falhas prematuras. Dentre as manifestações patológicas que mais transtorno e prejuízos causam às estruturas civis, destaca-se a corrosão de armaduras, por sua elevada incidência e potencial de dano. Embora já exista um considerável número de pesquisas acerca deste tema, percebe-se que a ênfase atual se encontra no estudo do processo de iniciação da corrosão, e poucos estudos se voltam para a caracterização da fase de propagação, onde os danos se intensificam. Assim, esta pesquisa tem a finalidade, pela realização de experimentos conjugados com uma análise numérica, de contribuir para que sejam entendidos os efeitos, em termos de prejuízo do desempenho estrutural, da propagação da corrosão em estruturas civis. Para fins desta pesquisa, consideraram-se como efeitos significativos nas propriedades estruturais: a perda da aderência entre o aço e o concreto; a diminuição da área de seção transversal da armadura; a diminuição da resistência à tração do aço; e o aparecimento de tensões de tração devido ao acúmulo dos produtos de corrosão junto às barras. Foi estimulado o desenvolvimento de processos de corrosão em corpos-de-prova de concreto contendo barras de aço, que usa aplicação de corrente constante e exposição a uma solução de cloretos, e os graus de corrosão estudados foram equivalentes a perdas de massa de 0, 2, 5, 10 e 20%. Os resultados obtidos nesta fase experimental foram empregados como referência para uma análise numérica, cuja validação foi feita pela avaliação de vigas moldadas e deterioradas em laboratório pelo processo de corrosão induzido. Os resultados da pesquisa mostram, em suma, que os corpos-de-prova de concreto afetados pela corrosão de armaduras, devido ao ataque por cloretos, com pequenas perdas de massa (da ordem de 2 e 5%) não apresentam danos significativos nas propriedades estruturais, enquanto que nos corpos-de-prova contaminados com graus de corrosão maiores que 10% estes danos são mais evidenciados, e neste caso as estruturas devem ser obrigatoriamente tratadas ou recuperadas nos casos mais críticos. / When reinforced concrete was designed, it was believed to be a material with good durability and great life-cycle, with almost no repairs necessary. With its use intensification, however, it started to be noticed several deterioration processes and, in the most critical cases, these deterioration processes severely compromised the structure performance or leaded to early fails. Among the pathological manifestations which cause more damages to civil structures, it is possible to highlight the reinforcement corrosion due to its great incidence and damage potential. Despite the great amount of researches concerning this issue, the up-to-date emphasis is based on the corrosion initiation process study, and fewer studies focus on the propagation phase characterization, in which damages are intensified. This research aims, trough experimental and numerical analysis, to contribute for a better understanding of the effects, regarding structural performance damage, of corrosion propagation in civil structures. In this research it is considered as important effects on structural proprieties: losses of bond between steel and concrete; the bar cross section reduction; the bar tensile strength reduction; and the development of tension efforts due to rust near the bars. It was stimulated the development of corrosion process in concrete specimens with rebars, which uses constant current impression and chloride solution exposition to accelerate the corrosive process, and the corrosion levels studied were equivalent to bar weight losses of 0, 2, 5, 10 and 20%. The results from this experimental phase were used as reference to numerical analysis, and validated by beams which were cast and deteriorated in laboratory due to inducted corrosion process. The research results show, in a few words, that concrete specimens affected by reinforcement corrosion, due to chloride attack, with low levels of mass losses (approximately 2 and 5%) do not present significant structural properties damages, while in the specimens with corrosion levels higher then 10% these damages are more exposed, and in this case the structures should be obligatory treated or recovered in the most critical cases.
870

Estudo do processo de cromatização de arames galvanizados e propostas de alternativas para retardamento da ocorrência prematura de oxidação branca

Rosa, Rogério Laydner da January 2009 (has links)
Este trabalho apresenta um estudo do processo de cromatização de arames galvanizados da Linha de Galvanização 2 da Gerdau Riograndense através do entendimento das variáveis de processo que podem ser alteradas com o intuito de proporcionar uma resistência à oxidação branca maior do que a fornecida com os parâmetros de processo utilizados atualmente. Amostras de arames foram coletadas diretamente da linha de galvanização e submetidas a ensaios acelerados de corrosão em câmaras de umidade saturada (NBR 8095 e ISO 6270-2)16 e de névoa salina (NBR 8094 e ASTM B 117)15. Com base nos resultados obtidos destes ensaios são propostas alterações nas variáveis de processo, como por exemplo, tempo de imersão no tanque de cromatizante, avaliando o aumento ou não do poder protetivo. Os resultados obtidos até agora mostraram que as configurações operacionais da Linha de Galvanização 2 não oferecem uma condição para a formação de uma camada protetora eficiente. Espera-se com este trabalho justificar junto à Empresa a necessidade de alteração de parâmetros de processo para que se consiga obter significativo aumento no poder protetivo conferido pelo cromatizante ao arame galvanizado, e assim, ter condições de disponibilizar ao mercado um produto com qualidade superior no que tange a resistência à oxidação branca. / This work presents a study about the chromatization process for galvanized steel wires in the Galvanizing Line 2 of the Gerdau Riograndense through the understanding of variables of the process that can be modified to provide a superior white corrosion resistance than the one which is provided actually. Samples of wires were collected directly from the galvanizing line and submitted to accelerated corrosion tests in the saturated humidity chamber (NBR 8095 and ISO 6270-2)16 and the salt spray chamber (NBR 8094 and ASTM B 117)15. Based in the results from this tests changes in the process variables are proposed like immersion time in the chromatizating bath to evaluate the increase or decrease of the protective action. The results obtained so far showed that the operational configurations of the Galvanizing Line 2 do not offer a good condition to create an efficient protective layer on the wire. The expectation of this work is to justify to the company that changes in the parameters process are necessaries to get a significant increasing of the protective chromatizating action on the galvanized wire and this way to have conditions to offer to costumers a product with superior quality about white corrosion resistance.

Page generated in 0.0412 seconds