• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1965
  • 16
  • 13
  • 12
  • 8
  • 7
  • 7
  • 7
  • 5
  • 3
  • 2
  • 1
  • Tagged with
  • 2044
  • 1009
  • 666
  • 590
  • 501
  • 427
  • 416
  • 283
  • 278
  • 276
  • 265
  • 255
  • 226
  • 223
  • 214
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
661

Estudos da formação de trihalometanos a partir de substâncias húmicas aquáticas tratadas com cloro e dióxido de cloro / Not available

Carvalho, Eduarda Regina 26 August 2003 (has links)
Este trabalho teve por finalidade, em um primeiro estágio, avaliar as características e propriedades estruturais das substâncias húmicas aquáticas, extraídas de um manancial de área tropical, incluindo avaliações e comparações de suas frações húmica e fúlvica, com a utilização de técnicas espectroscópicas como RPE, RMN, IV, Fluorescência e absorbância de luz UV-Visível, além da aplicação de técnicas cromatográficas. A base para o entendimento sobre essas matrizes foi possível, obtendo informações quanto ao grau de humificação e condensação, composição elementar e estrutural. Os resultados obtidos, reforçam a importância, de utilizar-se diversas técnicas independentes, para o estudo de materiais tão complexos e heterogêneos como as substâncias húmicas e demonstram as potencialidades destas (técnicas) no estudo da estrutura e reatividade dessas substâncias e suas interações. Na etapa seguinte, avaliou-se a influência de oxidantes de água, como o cloro e o dióxido de cloro, na formação de subprodutos com potencial carcinogênico, como os trihalometanos (no caso o clorofórmio), os quais são gerados após a oxidação da matéria orgânica aquática, por oxidantes de água, visando o monitoramento da formação desse subproduto sob condições brasileiras. Observou-se um pico de máxima formação, para este trihalometano, após um período de 24 horas de reação, para ambos oxidantes. Este resultado sugere cuidados operacionais em sistemas de abastecimento de água, quando esta for distribuída a população. Após 24 horas de reação a formação do clorofórmio, em amostras com dióxido de cloro, foi em torno de 60 vezes menor, quando comparado às amostras com cloro, para uma concentração dos oxidantes de 20 μg L-1. Mostrou-se que o aumento da formação do clorofórmio, também ocorre para amostras a maiores valores de pH e concentração de matéria orgânica. Quando se variou a concentração dos ácidos fúlvicos nas amostras, a formação do clorofórmio foi de aproximadamente 9 μg L-1, para a amostra com maior concentração da matéria orgânica e na presença de cloro. Para a amostra com dióxido de cloro, essa formação foi de 0,20 μg L-1. Os resultados obtidos nesta fase mostraram que o dióxido de cloro é mais eficiente quando comparado ao cloro, quanto ao poder de oxidação da matéria orgânica e principalmente na redução da formação do clorofórmio (uma redução de mais de 98%) após reação com a fração fúlvica. Os experimentos, contribuíram para um melhor entendimento sobre as características das substâncias húmicas aquáticas na presença e ausência de alternativas oxidantes, e as informações obtidas, fornecem algumas opções operacionais que poderão contribuir, para o desenvolvimento de novos processos ou ajustes nos procedimentos do tratamento da água para consumo humano. Após esta etapa do trabalho foram utilizadas as técnicas espectroscópicas mencionadas acima, para avaliar as propriedades e características estruturais da fração fúlvica extraída de um manancial de área tropical, na presença dos oxidantes. Os resultados geraram dados inéditos e coerentes entre si, sobre alterações estruturais nos ácidos fúlvicos aquáticos, na presença desses oxidantes, mostrando de forma inequívoca o envolvimento de grupos aromáticos condensados nas reações com os dois oxidantes / The aim of this work, at a first stage, was to evaluate the characteristics and structural properties of aquatic humic substances extracted of an aquatic environrnent of a tropical area. Also, the evaluation and comparison of humic and fulvic fractions were performed throughout spectroscopic techniques as EPR, NMR, FTIR, fluorescence and absorbance with UV-Visible light and using chromatographic techniques. The base for the understanding of these matrixes was possible through informations such as humification and condensation degree as well as elemental and structural composition. The results, obtained in this work, reinforce the importance to use several independent techniques to study complex and heterogeneous materials as humic substances and the potentiality of these techniques to generate data about the structure, reactivity and interactions of these substances. After this stage of the work, it was evaluated the influence of water oxidants (chlorine and chlorine dioxide) in the formation of subproducts with carcinogenic potential as the trihalomethanes (in this case the chloroform), which are generated after the oxidation of aquatic organic material by water oxidants. The formation of these subproducts was minimized under our tropical climatic conditions, and it was observed a peak of maximal formation after 24 hours of reaction, for both oxidants. This result indicates that operational cares should be taken, in water supply systems, when the water is distributed for the population. After 24 hours of reaction, the chloroform formation, in samples with chlorine dioxide was around 60 times smaller than in the samples containing chlorine, for a oxidants concentration of 20 μg L-1. Also, it was observed an increase of the chloroform formation for samples with the highest values of pH and organic matter concentration. When the fulvic acid concentration was changed, the chloroform formation was approximately 9 μg L-1 for the sample with the highest organic matter concentration and containing chlorine. In the case of the sample with chlorine dioxide, this formation was 0,20 μg L-1. The results obtained in the final fase, showed that the chlorine dioxide is more efficient to oxidize the organic matter than the chlorine and mainly in the reduction of chloroform formation (a reduction higher than 98%) after the reaction with the fulvic fraction. These experiments contributed for a better understanding about aquatic humic substances characteristics in the presence and absence of alternatives oxidants. The informations obtained in this work provide operational options, which will contribute for the development of new process or to adjust the water treatment proceduces for human consumption. Also, the previously mentioned spectroscopic techniques were used to evaluate the properties and structural characteristics of the fulvic fraction extracted of a tropical area source. Results generated news and coherent data about structural alterations in fulvic acid samples containing oxidants, showing clearly the influence of the condensed aromatic moieties in reactions with both oxidants.
662

Perfil da cocaína comercializada como crack na região Metropolitana de São Paulo em período de vinte meses (2008-2009) / Profile marketed as crack cocaine in the metropolitan region of Sao Paulo in the period of twenty months (2008-2009).

Fukushima, André Rinaldi 14 December 2010 (has links)
A adição de diferentes substâncias (adulterantes e diluentes) no crack (freebase) é um fenômeno bem conhecido no mercado ilícito. Os adulterantes podem interagir com a cocaína e determinar novas e desconhecidas síndromes tóxicas influindo no estado clínico das intoxicações, especialmente em casos em que houve modificação das vias de administração. No Brasil a análise de adulterantes, contaminantes e/ou diluentes adicionados ao crack não constitui rotina nos laboratórios oficiais. Nesse contexto, o presente trabalho pretendeu a caracterização de um grupo de amostras de crack que fornecerá informações na investigação sobre o narcotráfico, no estudo da morbi-letalidade, bem como na toxicovigilância. O método utilizado neste trabalho foi realizado com a técnica de cromatografia gasosa acoplada a detector em ionização de chamas CG-DIC. Os resultados obtidos nas análises de amostras provenientes de apreensões realizadas na região metropolitana de São Paulo num período de 20 meses, no período de março de 2008 a novembro de 2009, mostraram que 9,16% das amostras continham lidocaína, benzocaína e cafeína como adulterantes e 14,57% continham outros adulterantes totalizando 23,73%. O percentual em teor médio de cocaína presentes nas amostras de crack foi de 71,3%. Adicionalmente foram avaliadas as propriedades organolépticas. O resultado das análises das amostras estudadas mostrou maior teor de cocaína em relação à cocaína comercializada na forma de sal (cloridrato ou sulfato) comercializado como \"droga de rua\" no Estado de São Paulo. Ainda, os interferentes e adulterantes encontrados nas amostras estudadas permitem a inferência do importante problema de saúde pública advindos do uso dessa droga. / The addition of different substances (contaminants and fillers) in the crack (freebase) is a well known phenomenon in the illicit market. The contaminants can interact with cocaine and identify new and unknown toxic syndromes influencing the clinical state of intoxication, especially in cases where there was a modification of the routes. In Brazil, the analysis of adulterants, contaminants and / or extenders added to the crack is not routine in official laboratories. In this context, this work aims to characterize a sample group of crack that provides information on an investigation into drug trafficking in the study of morbidity and mortality, as well as toxicological. The method used in this study utilized the technique of gas chromatography coupled with flame ionization detector GC-FID. The analysis results of samples from seizures made in the metropolitan region of Sao Paulo in a period of 20 months, from March 2008 to November 2009 showed that 9.16% of the samples contained lidocaine, benzocaine, and caffeine as adulterants and 14.57% contained other adulterants totaling 23.73%. The average content in percentage of cocaine present in the samples of crack was 71.3%. Additionally, we evaluated the organoleptic properties of the row samples. The results of analysis of the samples tested showed higher levels of cocaine in the cocaine sold in the form of salt (hydrochloride or sulfate) marketed as \"street drug\" in the State of São Paulo. Still, the interferences and adulterants found in the samples studied allow the inference of important public health problem arising from the use of this drug.
663

Saliva: uma matriz alternativa para determinação de biomarcadores do cigarro em gestantes / Saliva: an alternative matrix for the determination of cigarette biomarkers in pregnant women

Gomes, Nayna Cândida 07 March 2018 (has links)
O tabagismo durante a gravidez é o principal fator de risco previsível associado com complicações tanto no parto quanto na gestação. Estão relacionados, por exemplo, partos prematuros, baixo peso ao nascer, doenças no trato respiratório do feto e, com a morte infantil. A exposição à fumaça do tabaco pode ser avaliada através da presença de nicotina e cotinina nos fluidos biológicos, incluindo plasma, soro, urina, saliva, cabelo e unha. A saliva é uma matriz alternativa que apresenta como vantagens a facilidade de obtenção, não é uma amostra invasiva, a coleta pode ser assistida, é de baixo custo, o risco de contração de infecções durante a coleta e manuseio da amostra é mínimo e pode ser utilizada em situações que é difícil a obtenção de outro tipo de amostra. Como a prevalência de gestantes fumantes de cigarro é relativamente alta, é importante uma confirmação por um laboratório de análise para classificar de forma correta e confiável se a gestante é fumante ou não. O objetivo desta pesquisa foi desenvolver e validar um método para análise de nicotina e cotinina em amostras de saliva de gestantes. Foi utilizada a extração líquido-líquido para o preparo das amostras de saliva e foi realizada a cromatografia em fase gasosa com detector termiônico específico para a separação, identificação e quantificação dos analitos nicotina, cotinina e do padrão interno ketamina. O limite de detecção foi de 10 ng/mL para nicotina e de 6 ng/mL para cotinina. Os limites inferiores de quantificação foram de 40 ng/mL e 20 ng/mL para a nicotina e cotinina, respectivamente. O método foi considerado linear na faixa de concentração de 40 a 2000 ng/mL (R=0,996) para a nicotina e de 20 a 2000 ng/mL (R=0,999) para a cotinina. Os valores de recuperação dos analitos variaram de 66,1% a 92,2%. A precisão intradia apresentou uma variação de 6,06% a 11,50% e a precisão interdia variou de 6,89% a 10,57%. A exatidão intradia variou de -11,29% a 19,81%, e os valores da exatidão interdia variaram de -11,78% a 13,08%. Ambos os analitos apresentaram estabilidade nas amostras biológicas e em solução. Na primeira avaliação (período gestacional de 1 a 25 semanas), o método foi aplicado em 259 amostras de saliva de gestantes fumantes e não fumantes. E na segunda (período gestacional de 36 a 40 semanas e até 113 dias após o parto), foi aplicado em 45 amostras de gestantes fumantes. Foi observada uma diferença significativa ao comparar o autorrelato das gestantes fumantes e não fumantes, na primeira avaliação, com a concentração de nicotina e cotinina nas amostras de saliva (p<0,001). As concentrações de cotinina em amostras de saliva correlacionaram positivamente com o número de cigarros consumidos diariamente pelas gestantes fumantes, na primeira avaliação (p<0,001). Não foram obtidas diferenças estaticamente significativas para as variáveis: número de cigarros diários (p=0,255), concentração de nicotina (p=0,949) e cotinina (p=0,665). O ponto de corte da nicotina foi maior que zero, com sensibilidade de 36,8% e especificidade de 97,7%. Para a cotinina, o ponto de corte foi maior que 17,2 ng/mL, com sensibilidade de 94,3% e especificidade de 98,8%. O método analítico desenvolvido e validado atendeu aos critérios exigidos pela resolução 27/2012 e à 899/2003 da Agência Nacional de Vigilância Sanitária. / Smoking during pregnancy is the main factor associated with complications in both and gestation. It is related, for example, premature births, low birth weight, diseases in the respiratory tract of the fetus and, with child death. Exposure to tobacco smoke can be assessed by the presence of nicotine and cotinine in biological fluids including plasma, serum, urine, saliva, hair and nails. The saliva is an alternative matrix that presents as advantages the ease of obtaining, is not an invasive sample, the collection can be assisted, it is of low cost, the risk of contraction of infections during the collection and handling of the sample is minimal and can be used in situations where it is difficult to obtain another type of sample. As the prevalence of pregnant cigarette smokers is relatively high, confirmation by an analysis laboratory is important to correctly and reliably classify whether the pregnant woman is a smoker or not. The objective of this research was to develop and validate a method for the analysis of nicotine and cotinine in saliva samples from pregnant women. Liquid-liquid extraction was used for the preparation of saliva samples and gas chromatography with specific thermionic detector was performed for the separation, identification and quantification of the analytes nicotine, cotinine and the internal standard ketamine. The limit of detection was 10 ng/mL for nicotine and 6 ng/mL for cotinine. The lower limits of quantification were 40 ng/mL and 20 ng/mL for nicotine and cotinine, respectively. The method was considered linear in the concentration range of 40 to 2000 ng/mL (R=0.996) for nicotine and 20-2000 ng/mL (R=0.999) for cotinine. The recovery values of the analytes range from 66.1% to 92.2%. The intraday precision ranged from 6.06% to 11.50% and the interday precision ranged from 6.89% to 10.57%. The intraday accuracy ranged from -11.29% to 19.81%, and the interday accuracy ranged from -11.78% to 13.08%. Both analytes presented stability in the biological samples and in solution. At the first evaluation (gestational period of 1 to 25 weeks), the method was applied to 259 saliva samples from pregnant smokers and nonsmokers. And in the second (gestational period of 36 to 40 weeks and up to 113 days postpartum), it was applied in 45 samples of pregnant smokers. A significant difference was observed when comparing the self-report of pregnant smokers and nonsmokers in the first evaluation with the concentration of nicotine and cotinine in saliva samples (p<0.001). The concentrations of cotinine in saliva samples correlated positively with the number of cigarettes consumed daily by pregnant smokers in the first evaluation (p<0.001). No statistically significant differences were found for the variables: number of daily cigarettes (p=0.255), nicotine concentration (p=0.949) and cotinine (p=0.665). The cutoff point of nicotine was greater than zero, with sensitivity of 36.8% and specificity of 97.7%. For cotinine, the cutoff point was greater than 17.2 ng/mL, with sensitivity of 94.3% and specificity of 98.8%. The analytical method developed and validated met the criteria required by resolution 27/2012 and 899/2003 of the National Sanitary Surveillance Agency.
664

\"Estudo dos extratos dos frutos de Sapindus saponaria enriquecidos em saponinas e outros glicosídeos e sua aplicação em eletroforese capilar\" / \"Study of Sapindus saponaria fruit?s extracts rich on saponins and other glycosides and their application in capillary electrophoresis\"

Guterres, Sheila Barreto 20 January 2006 (has links)
Os frutos de S. saponaria, espécie bastante abundante em São Carlos e outras regiões do Brasil são ricos em glicosídeos anfifílicos, ou seja, compostos por uma parte polar e outra apolar. Devido a esta peculiaridade tendem a formar espuma mostrando propriedades químicas semelhantes às dos tensoativos. Alguns destes glicosídeos pertencem à classe das saponinas e são constituídos por uma aglicona de estrutura carbônica a qual está ligada a uma ou duas cadeias de açúcar. O interesse pelas propriedades tensoativas deste glicosídeos motivou o estudo destas substâncias para uso em eletroforese capilar. Os frutos foram extraídos com metanol e fracionados em coluna cromatográfica preparativa utilizando sephadex LH-20 como fase estacionária. Após a eluição, as frações foram analisadas por espectrometria de massas e estudadas por eletroforese capilar. A eletroforese capilar de zona mostrou-se uma técnica viável para o estudo das frações obtidas. Embora um grau de pureza elevado não tenha sido alcançado, a fração B foi utilizada como aditivo para tampão em cromatografia eletrocinética micelar (MEKC) e uma interação diferenciada foi observada do nitrobenzeno com o tampão aditivado em relação ao tampão com SDS puro. / Sapindus saponaria is a very abundant species in São Carlos and others regions of Brazil. Fruits of S. saponaria have a high content of glycosides which possess well-defined regions of hydrophobic and hydrophilic feature denominated amphiphilic molecule. Thus, this can form a foam showing chemical proprieties equals to surfactants. Some glycosides belong to class of saponins and are composed of carbonic structure designates aglycone, which is linked in one or two sugar chains. The purpose of the present study was the use of glycosides due to their surfactants properties in further applications of capillary electrophoresis. The extraction of crude fruits was carried out with methanol and this extract was fractionated in Sephadex LH-20. The fractions were analyzed for mass spectrometry and studied in capillary electrophoresis (CE). This is a feasible technique for the study of fractions obtained. Although a high degree of purity was not reached, the fraction B were used as additive for the electrolyte background in MEKC. The nitrobenzene showed different interaction with micellar system in the electrolyte background with fraction B.
665

Estudos espectroscópicos e cromatográficos de substâncias húmicas de solos sob diferentes sistemas de preparo / Spectroscopic and chromatographic studies of humic substances from soils under different tillage systems

Novotny, Etelvino Henrique 13 June 2002 (has links)
Neste trabalho efetuou-se um detalhado estudo metodológico das técnicas empregadas para a caracterização espectroscópica e cromatográfica dos ácidos húmicos. Neste estudo demonstrou-se que outros fatores, além de características intrínsecas dos ácidos húmicos, podem afetar os resultados obtidos pelas diferentes técnicas espectroscópicas utilizadas. Dentre estes fatores o mais importante foi o íon vanadila (VO2+) residual que afetou drasticamente os resultados das análises espectroscópicas levando à supressão: dos sinais de RMN de 13C de grupos hidrofílicos; dos sinais de RPE dos radicais livres orgânicos; e da intensidade de fluorescência. Pela supressão seletiva dos sinais de RMN de 13C dos grupos carboxilas e daqueles associados a carboidratos foi possível inferir que estas estruturas possivelmente estejam diretamente envolvidas na complexação do VO2+, assim como a supressão dos sinais de fluorescência e de RPE dos radicais livres orgânicos indicaram que estes radicais e estruturas fluorescentes também podem estar envolvidas na complexação deste íon ou então o efeito do íon paramagnético pode difundir-se facilmente pela estrutura dos ácidos húmicos. Adicionalmente, os ácidos húmicos com maior conteúdo de VO2+ apresentaram um maior tamanho molecular aparente, indicando um possível efeito agregante deste íon. A análise multivariada dos dados obtidos possibilitou o isolamento destes efeitos do VO2+ e as novas variáveis obtidas pela técnica dos componentes principais, independentes do conteúdo deste íon, indicaram que o cultivo mais intenso do solo levou ao acúmulo relativo de estruturas mais recalcitrantes e com maiores conteúdos de estruturas associadas à lignina e C-Alquila de cadeia longa. Além disto, observou-se que o sinal dos radicais livres orgânicos dos ácidos húmicos era devido à pelo menos dois centros paramagnéticos distintos sendo que o VO2+ suprimiu preferencialmente o sinal com maior valor-g, atribuído a radicais livres orgânicos onde o elétron desemparelhado estaria delocalizado sobre átomos de oxigênio. / In this work it was realized a detailed methodological studies of spectroscopic and chromatographic techniques that were applied in the humic substances characterization. In these studies it was demonstrated that, besides the intrinsic characteristics of humic substances, there are other factors which can affect the results obtained with the different spectroscopic techniques utilized. Among these factors, the residual vanadyl ion (VO2+) affected drastically the spectroscopic results causing the suppression of: 13C NMR signals of hydrophilic groups; EPR signals from organic free radicals; and the fluorescence intensity. By the selective suppression of 13C NMR signals from carbohydrates and carboxyl groups it was proposed that these structures could possibly be directly involved in the VO2+ complexation. The suppression of fluorescence signals and EPR ones from organic free radicals indicated that or these radicals and the fluorescent structures can also be involved in the VO2+ complexation, either the paramagnetic ion effect can diffuse through the humic substances structures. In addition, the increase of VO2+ contents resulted in a higher apparent molecular size indicating a possibly aggregating effect of this ion. The multivariate analysis from the obtained data allowed the isolation of these effects from VO2+. The new variables obtained by the principal components technique, independent from that ion content, indicated that the most intense cultivation of the soil lead to the relative accumulation of more recalcitrant structures associated to lignin and long chain C-alkyl. Besides this, we observed that the organic free radicals signal from humic acids was due to at least two paramagnetic centers. The residual VO2+ suppressed preferentially the signal with the highest g-value. This signal was assignment to organic free radicals where the unpaired electron could be delocalized on oxygen atoms.
666

Métodos eletroforéticos e cromatográficos aplicados para a determinação simultânea de fármacos hipolipidêmicos em medicamentos / Electrophoretic and chromatographic methods apllied for the simultaneous determination of hypolipidemic drugs in medicines.

Souza, Antonio Marcos Callejo de 15 April 2015 (has links)
A ezetimiba e a sinvastatina são fármacos hipolipidêmicos. A ezetimiba pertence à nova classe das 2 - azetidinona, inibidores e bloqueadores do colesterol intestinal. A sinvastatina pertence à classe dos inibidores competitivos da hidroxi-3-metilglutarilcoenzima A redutase (HMG-CoA), que é a última etapa regulada na síntese do colesterol. O objetivo do trabalho foi desenvolver e validar métodos por cromatografia liquida de alta eficiência (HPLC) e eletroforese capilar (CE), rápidos, seletivos e confiáveis para determinação dos hipolipidêmicos em formulações farmacêuticas. A separação cromatográfica foi realizada usando coluna Nano separation technologies (NST) Cianopropril (CN) (150 mmx 4,6 mm, com partícula 3,5 &#181;m), e eluição isocrático usando água purificada: acetonitrila (48:52, v/v); vazão 0,8 mL/min e volume de injeção de 20 &#181;L. A temperatura da coluna foi de 35 ºC e a detecção foi realizada com detector na região do UV em 238 nm. O método por cromatografia eletrocinética micelar (MEKC) foi desenvolvido utilizando capilar de sílica fundida 30 cm (comprimento efetivo) x 50 &#181;m d.i. e eletrólito constituído de tetraborato de sódio (TBS) 20 mmol L-1: dodecil sulfato de sódio (SDS) 30 mmol L-1, pH 9,0 ajustado com 10% ácido fosfórico: acetonitrila 12% v/v. O tempo de injeção foi de 3 segundos com pressão hidrodinâmica de 20 mbar, voltagem aplicada de 30 kV e detecção no UV em 238 nm. Os métodos analíticos foram validados de acordo com os requerimentos vigentes da ANVISA, ICH e Farmacopéia Americana. Portanto, os métodos propostos demonstraram ser lineares, precisos, exatos e adequados para quantificação simultânea da ezetimiba e sinvastatina em formas farmacêuticas sólidas. / Ezetimibe and simvastatin are hipolipidemic drugs. Ezetimibe belongs to a new class of 2 - azetidione, inhibitors and blockers of intestinal chrolesterol. Simvastatin belongs a class of competitive inhibitors of 3-hydroxymethylglutaryl-coenzyme A (HMG-CoA) reductase, which is the last regulated step in the cholesterol synthesis. The aim of this project was to develop and validate fast, selective and reliable chromatographic and electrophoretic methods, to determine hypolipidemic drugs in pharmaceutical formulations. The chromatographic separation was carried out on a Nano separation technologies (NST) Cyanpropyl (CN) (150 mm x 4,6 mm, 3,5 &#181;m), isocratic elution using purified water: acetonitrila (48:52 v/v), the flow rate was 0,8 mL/min and the injection volume was 20 &#181;L. The column temperature was kept at 35 ºC and detection wavelength was set at 238 mn. The micellar electrokinetic chromatographic method was developed using a fused silica capillary column 30 cm (effective length) x 50 &#181;m i.d, the electrolyte was constituted of 20 mmol L-1 tetraborate buffer solution: 30 mmol L-1 sodium dodecyl sulphate (SDS), pH 9.0 adjusted with 10% phosphoric acid: 12 % v/v acetonitrile. The injection time was 3 s at 20 mbar, the applied voltage was 30 kV and detection was set at 238 nm. The both methods were developed and validated according to ANVISA, ICH and US Pharmacopeia guidelines. Therefore, the proposed methods proved to be linear, precise, accurate and suitable for simultaneous quantitation of ezetimibe and simvastatin in solid pharmaceutical formulations.
667

Desenvolvimento de métodos cromatográficos para análises de antimicrobianos em amostras complexas / Development of chromatographic methods for analysis of antimicrobials in complex samples

Melo, Lidervan de Paula 23 April 2012 (has links)
Este trabalho descreve o desenvolvimento de novos métodos cromatográficos em conjunto com técnicas de microextração para determinação de parabenos em produtos cosméticos e leite humano e rifampicina em amostras de plasma. Destaca-se também o desenvolvimento da fase extratora molecularmente impressa para extração em fase sólida (SPE) de parabenos em amostras de leite humano. O capítulo I descreve a avaliação da extração sortiva em barra de agitação (SBSE) em conjunto com a cromatografia líquida (LC) com detecção espectrofotométrica (LC-UV) para análises de parabenos em produtos cosméticos para fins de controle de qualidade. As variáveis do processo de extração SBSE, tais como tempo e temperatura de extração, pH e força iônica da amostra e condições de dessorção foram otimizadas para aumentar a sensibilidade analítica do método e diminuir o tempo de análise. O método SBSE/LC-UV desenvolvido apresentou faixa linear correspondente ao limite de quantificação (LQ) a 2,50 µg. mg-1 e coeficientes de determinação maiores que 0,993. Os valores de coeficiente de variação resultantes das análises de precisão interensaios foram 5,0% para todos os parabenos analisados e a exatidão variou de 90 a 100%. O método desenvolvido foi aplicado para análises de amostras de produtos cosméticos comerciais (cremes hidratantes, antitranspirantes em creme e filtros solares). O método SBSE/LC-UV padronizado e validado resultou nas seguintes vantagens em relação aos métodos convencionais: simplicidade no preparo de amostra, redução do volume de solvente orgânico e da quantidade de amostra utilizada. O capítulo II descreve o desenvolvimento da fase extratora molecularmente impressa para SPE de parabenos em amostras de leite humano e análises por cromatografia em fase líquida com detecção espectrofotométrica (SPE/LC-UV). Os polímeros de impressão molecular, materiais sintéticos baseados em sistemas biomiméticos, foram sintetizados através do processo sol-gel tendo como molde, o benzilparabeno. Após a remoção do molde, cavidades seletivas (sítios de reconhecimento molecular) ao benzilparabeno e análogos estruturais foram reveladas. O método SPE/LC desenvolvido apresentou faixa linear correspondente ao limite de quantificação a 150 ng. mL-1 e coeficientes de determinação 0,992. Os valores de coeficiente de variação resultantes das análises de precisão interensaios foram 13% e a exatidão variou de 86 a 117%. A aplicabilidade do método SPE/LC foi demonstrada através das análises de amostras de leite humano de lactantes. Segundo os parâmetros de validação analítica avaliados, o método padronizado SPE/LC-UV é adequado para análises de parabenos em amostras de leite humano. O capítulo III descreve a avaliação da microextraçao em fase sólida no capilar (in-tube SPME) acoplada à cromatografia líquida (LC) com detecção espectrofotométrica (LC-UV) para análises de rifampicina em amostras de plasma para fins de monitorização terapêutica. As variáveis in-tube SPME, tais como fase estacionária da coluna capilar, volume de amostra, ciclos aspirar/dispensar e vazão foram otimizadas visando obter maior eficiência do processo. O método in-tube SPME/LC desenvolvido apresentou faixa linear correspondente ao limite de quantificação (0,1 µg. mL-1) a 100 µg. mL-1 e coeficientes de determinação igual a 0,998. Os valores de coeficiente de variação resultantes das análises de precisão interensaios foram 2% e a exatidão variou de 83 a 92%. A aplicabilidade do método in-tube SPME/LC, padronizado e validado foi comprovada através das análises de amostras de plasma de pacientes em tratamento com rifampicina. O método in-tube SPME/LC resultou na automação do processo de análise, maior precisão analítica, menor tempo de análise, menor volume de solvente orgânico e de fluido biológico. / This work describes the development of chromatographic methods in combination with microextraction techniques for the determination of parabens in cosmetic and human milk samples and of rifampicin in plasma samples. The design of a molecularly imprinted extraction phase for the solid-phase extraction (SPE) analysis of parabens in human milk samples is also reported. Chapter I describes the evaluation of the stir bar sorptive extraction (SBSE) in combination with liquid chromatography (LC) with UV detection (LC-UV) for the analysis of parabens in cosmetics aiming at quality control. The SBSE variables such as extraction time, temperature, pH of the matrix, ionic strength, and desorption conditions have been optimized, in order to establish the parabens partition equilibrium in a short analysis time. The linear range of the SBSE/LC method lay from LOQ to 2.5 µg. mg-1, with a coefficient of determination higher than 0.993. The interday precision of the SBSE/LC method presented a coefficient of variation lower than 5%, and the accuracy ranged from 90 to 99%. The effectiveness of the proposed method for the analysis of commercial cosmetic products such as body creams, antiperspirant creams, and sunscreens has been proven. Therefore, the combination of SBSE with liquid desorption, followed by LC analysis, provides a simple, and selective tool for the analysis of parabens in cosmetic products using minimized volume of organic solvent as well as very small amount of the target sample. Chapter II presents the development of a molecularly imprinted extraction phase for the SPE analysis of parabens in human milk samples. The molecularly imprinted polymers, which are synthetic materials based on biomimetic systems, were synthesized by the sol-gel technology in the presence of the template (benzilparaben). After template removal, selective cavities (benzilparaben) were revealed for parabens selective extraction. The linear range of the SPE/LC method lay from LOQ to 150 ng. mL-1, with a coefficient of determination higher than 0.992. The interday precision of the SPE/LC method presented a coefficient of variation lower than 13%, and the accuracy ranged from 86 to 117%. The effectiveness of the proposed method for the analysis of human milk samples has been demonstrated. According to the evaluated analytical validation parameters, the SPE/LC-UV method is suitable for the analysis of parabens in human milk samples. Chapter III depicts the evaluation of solid-phase microextraction in the capillary (in-tube SPME) in combination with liquid chromatography (LC) with UV detection (LC-UV) for the analysis of rifampicin in plasma samples for therapeutic drug monitoring. The in-tube SPME/LC method was linear over the LOQ (0.1) to 100 g. mL-1 range, with a linear coefficient value (r2) of 0.998. The inter-assay precision presented coefficient of variation 2%, and the accuracy ranged from 83 to 92%. The effectiveness and practicability of the proposed method have been by analysis of plasma samples from ageing patients undergoing therapy with rifampicin. The in-tube SPME/LC method allowed for automated continuous sample preparation (extraction, concentration, desorption, and injection of analytes) and minimized the analysis time as well as the volumes of organic solvent and biological fluid.
668

Avaliação cromatográfica e estudos de sorção e de toxicidade em minhocas de deltametrina, glifosato e ácido aminometilfosfônico / Chromatographic evaluation and sorption studies and toxicity in earthworms of deltamethrin, glyphosate and aminomethylphosphonic acid

Benetti, Fernanda 10 December 2015 (has links)
No Brasil é sabido que o uso de insumos agrícolas para o melhoramento da produtividade é crescente. Dentre esses insumos, pode-se destacar o uso de pesticidas. Neste trabalho foi desenvolvida e validada metodologia para análise de deltametrina (um piretróide usado como inseticida) por CLAE/UV. Nessas amostras também foram avaliadas a presença de glifosato (uma glicina substituída usada como herbicida) e de seu metabólito, o AMPA, via CG/EM. Essas metodologias foram aplicadas para análise de amostras reais de água, solo e sedimento no município de São Carlos, a fim de avaliar a contaminação por esses xenobióticos. Para melhor elucidação do potencial contaminante e de lixiviação destes, avaliou-se sua interação com ácidos húmicos, além de estudos de adsorção em latossolo vermelho, onde se verificou a grande influência da matéria orgânica na retenção de xenobióticos no solo. A fim de propor um método de remediação de solos em casos de contaminação por derramamento de formulações comerciais, testes de toxicidade (mortalidade, biomassa e reprodução) envolvendo minhocas Eisenia foetida com adição de 3% de vermicomposto foram executados. Todo o trabalho foi desenvolvido respeitando os conceitos de Gestão de Qualidade contempladas na norma ISO 17025. / In Brazil it is known that the use of agricultural inputs to improve productivity has been increasing. Among these inputs, we can highlight the use of pesticides. This work developed and validated a methodology for deltamethrin analysis (a pyrethroid used as insecticide) by HPLC/UV. These samples were evaluated in the presence of glyphosate (a substituted glycine used as herbicide) and its metabolite, AMPA, by GC/MS. These methodologies were applied to analyze real samples of water, soil and sediment in São Carlos in order to evaluate the contamination by these xenobiotics. To elucidate the potential contaminant and leaching of these, we also evaluated the interaction with humic acids, and adsorption studies were performed in red latosol where there was a great influence of organic matter on xenobiotics retention in the soil. So as to propose a method for remediation of soils in cases of contamination by shedding of commercial formulations in soil, three toxicity tests (mortality, biomass and reproduction) involving Eisenia foetida earthworms with the addition of 3% of hummus were performed. All the study was developed in compliance with the Quality Management concepts covered in ISO 17025.
669

Purificação da gonadotrofina coriônica eqüina, do plasma sanguíneo de éguas prenhes, por cromatografia de afinidade / Equine chorionic gonadotrophin purification, from pregnant mare plasma, by affinity chromatography

Rossa, Luis Augusto Ferreira 26 June 2009 (has links)
A Gonadotrofina Coriônica Eqüina (eCG) é produzida pela égua prenhe e tem ação folículo estimulante e luteinizante em animais domésticos não eqüídeos. Um pool formado por plasma de 4 éguas prenhes, com média de 69 dias de gestação, foi purificado em coluna cromatográfica com resina de afinidade Blue Sepharose FF (BS). As frações que adsorveram à resina BS foram purificadas em coluna cromatográfica com resina de afinidade Concanavalina A 4B (ConA). As frações que não adsorveram à resina BS também foram purificadas em coluna cromatográfica com resina de afinidade ConA. O mesmo pool de palsma foi diafiltrado, em cartucho de hemodiálise. O diafiltrado foi aplicado em coluna cromatográfica com resina de afinidade ConA. Atividade biológica (UI/mL) do plasma, do diafiltrado e das frações purificadas foram quantificadas por ensaio biológico com ratas impúbres. As atividades biológicas encontradas no plasma e no plasma diafiltrado foram de 3,63 e 5,14UI/mL, respectivamente. A atividade biológica encontrada nas frações que adsorveram à BS foi de 3,50UI/mL. Não foi encontrarda atividade biológica nas frações que não adsorveram à BS. A atividade biológica contida nas frações que adsorveram à BS e que também adsorveram a ConA foi de 3,65UI/mL. O rendimento do processo cromatográfico onde o plasma foi adsorvido pela BS e pela ConA, foi de 69,52%. Não foi encontrada atividade biológica nas frações obtidas da aplicação do plasma diafiltrado em coluna de ConA. O processo cromatográfico com uso de BS seguido de ConA mostou-se eficaz em purificar a eCG do plasma de éguas prenhes. / The equine Chorionic Gonadotrophin (eCG) is produced by the pregnant mare and has follicle-stimulant and luteinizing actions on non-equine domestic animals. A pool formed by the plasma of 4 pregnant mares (with mean gestation of 69 days) was purified in chromatographic column with Blue-Sepharose FF affinity resin (BS resin). Fractions adsorbed by BS resin were then purified in chromatographic column with Concavalin A 4B affinity resin (ConA resin). The fractions not adsorbed by the BS resin were also purified in chromatographic column with ConA resin. The same plasma pool was dialyzed in hemodialysis cartridge. The dialyzed was applied in chromatographic column with ConA resin. Biological activities (in IU/mL) of the plasma, of the dialyzed and of the purified fractions were quantified in a biological assay with female rats that did not reach puberty. The biological activities found in the plasma and dialyzed were of 3.63 and 5.14 IU/mL, respectively. Fractions that were adsorbed by BS had a biological activity of 3.50 IU/mL. No biological activity was found in fractions that were not adsorbed by BS. Biological activity found in fractions adsorbed by both BS and ConA was of 3.65 IU/mL. When plasma was both adsorbed by BS and ConA, the chromatographic process yield had results of 69.52%. No biological activity was found in the fractions obtained from the administration of dialyzed plasma in ConA column. The BS - followed by ConA -chromatographic process showed efficacy in purifying the eCG from the plasma of pregnant mares.
670

Avaliação da Cromatografia Líquida de Alta Eficiência e Eletroforese Capilar no Estudo in vitro do Metabolismo Enantiosseletivo da Hidroxicloroquina / High-Performance Liquid Chromatography and Capillary Electrophoresis avaliation in the in vitro study of hydroxychloroquine enantioselective metabolism.

Cardoso, Carmem Dickow 15 March 2006 (has links)
A hidroxicloroquina (HCQ) é um importante fármaco quiral usado, principalmente, no tratamento de artrite reumatóide, lupus eritematoso sistêmico e malária e cujas propriedades farmacocinéticas e farmacodinâmicas são estereosseletivas. Em relação às propriedades farmacocinéticas, alguns estudos prévios indicam que o metabolismo estereosseletivo parece ser função da espécie estudada, o que implica na necessidade de métodos seletivos para a determinação de seus enantiômeros em materiais biológicos. Assim, propôs-se o desenvolvimento e a validação de métodos para análise dos enantiômeros do fármaco inalterado e de seus principais metabólitos em frações microssomais de homogeneizados de fígado de ratos e camundongos. Para tanto foram empregadas as técnicas de eletroforese capilar (CE) e de cromatografia líquida de alta eficiência (HPLC). Inicialmente foi desenvolvido um método por HPLC, em uma etapa, para a quantificação dos enantiômeros de dois metabólitos da HCQ, desetilcloroquina (DCQ) e desetilhidroxicloroquina (DHCQ) em microssomas de fígado de ratos e camundongos. A separação foi efetuada utilizando-se a coluna Chiralpak AD-RH e hexano:isopropanol (92:8, v/v) acrescido de 0,1% de dietilamina como fase móvel. O procedimento de extração líquido-líquido foi utilizado para a preparação das amostras. A metodologia desenvolvida resultou na completa resolução dos enantiômeros da HCQ, DCQ e DHCQ e pode ser considerada adequada, visto que os parâmetros de validação mostraram valores dentro dos limites exigidos na literatura. O segundo método desenvolvido permitiu a quantificação dos enantiômeros dos três metabólitos da HCQ: DCQ, DHCQ e bisdesetilcloroquina (BDCQ) em microssomas de fígado de camundongos. A separação foi efetuada utilizando-se um tubo capilar de sílica fundida e solução do eletrólito tris(hidroximetil)aminometano 100 mmol/L, ajustada a pH 9,0 com ácido fosfórico e acrescida de 1% (m/v) de &#946; –CD - sulfatada e 30 mmol/L de &#946; –CD - hidroxipropilada. O procedimento de extração líquido-líquido foi eficiente para remover interferentes e os parâmetros de validação mostraram valores dentro dos limites exigidos na literatura. Os métodos desenvolvidos foram aplicados no estudo in vitro do metabolismo da HCQ em frações microssomais de fígado dos animais, verificando-se que o principal metabólito formado é o (-)-(R)-DHCQ, para ambas espécies estudadas. / Hydroxychloroquine (HCQ) is an important chiral drug used specially in the treatment of rheumatoid arthritis, systemic lupus erythematosus and malaria, with stereoselective pharmacokinetic and pharmacodinamic properties. Concerning these properties, some previous studies indicate that the stereoselective metabolism seems to be a function of the studied species, therefore selective methods are required for the determination of its enantiomers in biological matrix. Thus, the present work reports the development and validation of methods for the analysis of the enantiomers of HCQ and its main metabolites in microsomal fraction of rats and mice liver homogenates. Capillary electrophoresis (CE) and high-performance liquid chromatography (HPLC) were used for this purpose. Initially, a one-step HPLC method was developed for the quantification of the enantiomers of two HCQ metabolites, desethylchloroquine (DCQ) and desethylhydroxychloroquine (DHCQ) in microsomal fraction of rats and mice liver homogenates. The separation was performed on a Chiralpak AD-RH column using hexane:isopropanol (92:8, v/v) plus 0.1% diethylamine as the mobile phase. Liquid-liquid extraction procedure was used for sample preparation. The developed methodology resulted in the complete resolution of HCQ, DCQ and DHCQ enantiomers and can be considered suitable because the validation parameters are in accordance with the limits established in the literature. The second developed method allowed the quantification of the enantiomers of the three HCQ metabolites, DCQ, DHCQ and bisdesethylchloroquine (BDCQ) in microsomal fraction of mice liver homogenates. The separation was performed using a fused-silica capillary tube and tris (hydroxymethyl) aminometane 100 mmol/L electrolyte solution, adjusted at pH 9.0 with phosphoric acid, containing 1% (w/v) sulfated- &#946; -CD and 30 mmol/L hydroxypropyl- &#946; -CD. The liquid-liquid extraction procedure was efficient to remove interferents and the validation parameters showed values within accordance to the literature. The developed methods were applied in the in vitro metabolism study of HCQ in microsomal fractions of the liver of the animals and it was verified that the main metabolite formed is (-)-(R)-DHCQ for both animal species studied.

Page generated in 0.0969 seconds