• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • 1
  • Tagged with
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Etude des propriétés du couplage d'échange dans des nano-structures de type ferromagnétique/multiferroïque / Study of the exchange bias properties in ferromagnetic/multiferroic nanostructures

Richy, Jérôme 29 November 2016 (has links)
Ce travail de thèse est consacré à l’étude du couplage d’échange dans des nano-structures de type ferromagnétique-multiferroïque, avec un intérêt particulier dans la compréhension du renversement en température et angulaire de l’aimantation.Au niveau théorique, un modèle numérique de renversement en température de l’aimantation dans des nanoparticules de type cœur-coquille sera présenté. Le code source du programme, implémenté au cours de cette thèse, a été rendu disponible pour la communauté scientifique sous licence libre. Il permet notamment d’introduire une dispersion en taille des particules, et démontrera le rôle clé de la distribution en taille et de la température dans la réponse magnétique des nanoparticules.Au niveau expérimental, une bicouche composée d’un ferromagnétique Ni81Fe19, et d’un multiferroïque magnétoélectrique à température ambianteBiFeO3, est étudiée. Ces couches sont déposées par pulvérisation cathodique radiofréquence, selon différentes épaisseurs de BiFeO3. Leur structure ainsi que leur morphologie sont caractérisées par diffraction des rayons X, microscopie à force atomique et microscopie électronique à transmission, révélant en particulier la polycristallinité de BiFeO3. Le renversement de l’aimantation est analysé par magnétométrie vectorielle à échantillon vibrant, fournissant des mesures angulaires à température ambiante et à 77 K, à l’aide d’un cryostat à immersion développé au cours de cette thèse ; ainsi que par magnétométrie SQUID, avec l’application de deux protocoles spécifiques de refroidissement en température (entre 10 K et 380 K). Les résultats montrent un comportement similaire à ceux obtenus sur des bicouches épitaxiées. Une propriété intrinsèque du BiFeO3 sera proposée comme étant un mécanisme possible conduisant au comportement en température obtenu, à savoir le cantage des spins de BiFeO3 conduisant à une contribution biquadratique du couplage d’échange. Finalement, un phénomène nouveau dans les matériaux couplés par échange sera mis en évidence à température ambiante, c’est-à-dire un traînage angulaire des axes d’anisotropie. / This dissertation presents a study of the exchange coupling in ferromagnetic-multiferroic nanostructures, with specific interest in understanding the thermal and angular reversal of the magnetization.A theorical numerical model of the thermal magnetization reversal in core-shell nanoparticles is presented. The program source code, implemented during this thesis, is freely avaibale to the scientific community under an open-source license. This model, developed during this thesis, allows diameter size dispersion, and demonstrates the key role of the size distribution and temperature in the magnetic response of nanoparticles.The experimentally studied bilayer is composed of a ferromagnetic material, Ni81Fe19, and a room temperature magnetoelectric multiferroic, BiFeO3. Different thicknesses in BiFeO3 were deposited. The structure and morphology of the bilayers were studied using X-ray diffraction, atomic force microscopy and transmission electron microscopy, revealing in particular the BiFeO3 polycristallinity. The magnetization reversal was probed by vectorial vibrating magnetometry, at room temperature and 77 K, using a self-developped immersive cryostat. The SQUID magnetometry allowed the measurement of two specific cooling protocols between 10 K and 380 K. The results of these two different protocols are similar to the ones obtained for measurements previously reported on expitaxial BiFeO3. An intrinsic property of BiFeO3 is proposed as being the driving mechanism for the thermal dependent magnetization reversal: the canting of the BiFeO3 spins leading to a biquadratic contribution to the exchange coupling. Finally, a new phenomenon in exchange coupled materials is shown at room temperature, which corresponds to an angular training of the anisotropy axes.
2

Instrumentation on silicon detectors: from properties characterization to applications

Dinu, N. 09 October 2013 (has links) (PDF)
L'utilisation optimale, dans des applications spécifiques, des Détecteurs Silicium nécessite une connaissance approfondie des phénomènes physiques sous-jacents. Dans ce mémoire, cette idée conductrice est appliquée à deux types de détecteurs : (1) les SiPM et leurs applications en imagerie médicale (2) les détecteurs à pixels planaires (PPS) et leurs applications dans la mise-à-jour du détecteur interne d'ATLAS pour le LHC à haute luminosité. Mon travail personnel sur les SiPM a débuté il y a environ 10 ans. Ainsi la partie (A) de mon HDR rappelle tout d'abord le principe physique de la photodiode à avalanche en mode Geiger (GM-APD), qui constitue la cellule élémentaire d'un SiPM. Puis le fonctionnement du SiPM est développé, avec ses principales caractéristiques physiques, ainsi que les montages expérimentaux mis en œuvre et les mesures de ces paramètres sur les productions des principaux fabricants. La dépendance en température des paramètres des SiPM constitue un inconvénient majeur dans certaines applications, aussi mon travail personnel montre comment on peut en grande partie s'affranchir de cette dépendance, en contrôlant certains paramètres de fonctionnement. Les détecteurs à SiPM présentent des avantages très intéressants au plan électrique, optique, mécanique, etc ..., permettant des applications multiples dans des domaines où une grande surface de détection est requise. Ainsi, les matrices de SiPM sont des composants très attractifs pour des applications d'imagerie médicale. Mon travail dans deux applications de ce type est détaillé : PET à haute résolution pour des petits animaux, et détecteur de radiation portatif pour l'aide à la localisation in situ de tumeurs solides. En parallèle à l'activité SiPM, j'ai été impliquée ces dernières années dans la conception et la caractérisation de nouveaux détecteurs à pixel planaires pour "l'upgrade" de l'expérience ATLAS. La partie (B) de mon HDR expose ainsi les méthodes expérimentales, comme "Secondary Ion Mass Spectrometry (SIMS)" et "Spreading Resistance Profiling" (SRP), utilisées pour la mesure de profils de dopage pour le détecteurs PPS. Je démontre ainsi l'importance de ces mesures pour le contrôle du process de fabrication, et la calibration des simulations TCAD (Technology-Computed Aided Design). Les résultats des simulations prévoyant le comportement des nouveaux détecteurs planaires proposés, avec des caractéristiques géométriques et une résistance aux radiations améliorées, sont présentés.

Page generated in 0.105 seconds