• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 42
  • 12
  • Tagged with
  • 54
  • 37
  • 29
  • 12
  • 11
  • 9
  • 9
  • 9
  • 9
  • 8
  • 6
  • 6
  • 5
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Influência da foto-oxidação no design de produtos : levantamentos técnico-científicos para reciclagem de produtos eletroeletrônicos

Dilly, Jaqueline January 2016 (has links)
No contexto em que vivemos é crescente a necessidade de reciclar materiais, principalmente, devido a questões que envolvam a redução dos impactos ambientais, como, por exemplo, a reciclagem de materiais para fabricação de produtos tecnológicos. Equipamentos eletroeletrônicos possuem grande potencial para reciclagem e são descartados diariamente. A degradação por foto-oxidação é um fator que pode influenciar nas propriedades dos polímeros que compõe um equipamento eletroeletrônico, e em sua reciclagem, mesmo em ambientes internos, pois o UVA tem capacidade de transpor janelas de vidro. Este estudo analisou alguns aspectos da foto-oxidação do poliestireno de alto impacto (PS-HI) reciclado de carcaças de impressoras, exposto à radiação UVA com base nas normas de envelhecimento ASTM G24 e G154. Amostras de PS-HI virgem e reciclado foram injetadas e expostas ao envelhecimento acelerado em laboratório por meio de grades, com a exposição total das amostras, e em máscara, com o direcionamento da radiação UVA em ponto determinado das amostras. As consequências da foto-oxidação nas propriedades das amostras foram caracterizadas por: Colorimetria, Espectroscopia de Infravermelho, Microscopia Eletrônica de Varredura e Análise Térmica Dinâmico Mecânico, com o objetivo de avaliar a degradação foto-oxidativa do poliestireno de alto impacto reciclado e caracterizar e as diferenças entre a exposição total e direcionada. Os resultados apontaram que as amostras recicladas expostas a radiação UVA não apresentaram mudanças consideráveis em relação as suas propriedades ou processabilidade quando comparado com o material virgem, pois a foto-oxidação ficou concentrada na superfície das amostras. / In today’s context it is increasingly necessary to recycle materials, such as the ones used in the manufacturing of technological products, mainly due to issues involving the reduction of environmental impact. Electronic devices are discarded daily and they have a great potential for recycling. Degradation by photo-oxidation is a factor that can influence the properties and the recycling of polymers that make up pieces of electronic equipment. This factor exists even indoors, because UVA is able to travel across glass windows. This study analyzes some aspects of the photo-oxidation of high impact polystyrene (HIPS) recycled from printer carcasses that were exposed to UVA under the ASTM G24 and G154 aging standards. Virgin and recycled HIPS samples were injected and exposed to an accelerated aging process in the laboratory through the use of pallets, with the total exposure of the samples, and masks with the targeted UVA exposure at certain points of the samples. The consequences of the photo-oxidation on the properties of the samples were characterized by: colorimetry, infrared spectroscopy, scanning electron microscopy and Dynamic Mechanical Thermal Analysis with the objectives of evaluating the degradation of recycled HIPS caused by photo-oxidation and characterizing the differences between pallet and mask exposure. The results showed that when compared to the virgin material, the recycled samples that were exposed to UVA radiation did not undergo significant changes regarding the properties and processability because the photo-oxidation effect remained focused on the areas near the surface of the samples.
22

Influência da foto-oxidação no design de produtos : levantamentos técnico-científicos para reciclagem de produtos eletroeletrônicos

Dilly, Jaqueline January 2016 (has links)
No contexto em que vivemos é crescente a necessidade de reciclar materiais, principalmente, devido a questões que envolvam a redução dos impactos ambientais, como, por exemplo, a reciclagem de materiais para fabricação de produtos tecnológicos. Equipamentos eletroeletrônicos possuem grande potencial para reciclagem e são descartados diariamente. A degradação por foto-oxidação é um fator que pode influenciar nas propriedades dos polímeros que compõe um equipamento eletroeletrônico, e em sua reciclagem, mesmo em ambientes internos, pois o UVA tem capacidade de transpor janelas de vidro. Este estudo analisou alguns aspectos da foto-oxidação do poliestireno de alto impacto (PS-HI) reciclado de carcaças de impressoras, exposto à radiação UVA com base nas normas de envelhecimento ASTM G24 e G154. Amostras de PS-HI virgem e reciclado foram injetadas e expostas ao envelhecimento acelerado em laboratório por meio de grades, com a exposição total das amostras, e em máscara, com o direcionamento da radiação UVA em ponto determinado das amostras. As consequências da foto-oxidação nas propriedades das amostras foram caracterizadas por: Colorimetria, Espectroscopia de Infravermelho, Microscopia Eletrônica de Varredura e Análise Térmica Dinâmico Mecânico, com o objetivo de avaliar a degradação foto-oxidativa do poliestireno de alto impacto reciclado e caracterizar e as diferenças entre a exposição total e direcionada. Os resultados apontaram que as amostras recicladas expostas a radiação UVA não apresentaram mudanças consideráveis em relação as suas propriedades ou processabilidade quando comparado com o material virgem, pois a foto-oxidação ficou concentrada na superfície das amostras. / In today’s context it is increasingly necessary to recycle materials, such as the ones used in the manufacturing of technological products, mainly due to issues involving the reduction of environmental impact. Electronic devices are discarded daily and they have a great potential for recycling. Degradation by photo-oxidation is a factor that can influence the properties and the recycling of polymers that make up pieces of electronic equipment. This factor exists even indoors, because UVA is able to travel across glass windows. This study analyzes some aspects of the photo-oxidation of high impact polystyrene (HIPS) recycled from printer carcasses that were exposed to UVA under the ASTM G24 and G154 aging standards. Virgin and recycled HIPS samples were injected and exposed to an accelerated aging process in the laboratory through the use of pallets, with the total exposure of the samples, and masks with the targeted UVA exposure at certain points of the samples. The consequences of the photo-oxidation on the properties of the samples were characterized by: colorimetry, infrared spectroscopy, scanning electron microscopy and Dynamic Mechanical Thermal Analysis with the objectives of evaluating the degradation of recycled HIPS caused by photo-oxidation and characterizing the differences between pallet and mask exposure. The results showed that when compared to the virgin material, the recycled samples that were exposed to UVA radiation did not undergo significant changes regarding the properties and processability because the photo-oxidation effect remained focused on the areas near the surface of the samples.
23

Controle de qualidade e avaliação das propriedades tecnológicas das formas polimórficas de talidomida / Quality control and evaluation of technological properties of polymorphic forms of thalidomide

Silva, Ana Paula Cappra January 2011 (has links)
A talidomida foi amplamente prescrita entre 1950 e 1960, em quase 50 países, como hipnosedativo não-barbitúrico e antiemético para indisposição matinal durante a gravidez, sendo em seguida fortemente controlada em função da ocorrência de sérios problemas de teratogenicidade. Nos últimos anos, vários esforços foram realizados no sentido de buscar identificar e elucidar as propriedades antiinflamatórias, imunomodulatórias e antiangiogênicas da talidomida. Na mesma direção, investigações clínicas foram conduzidas em pacientes com diversas doenças, como mieloma múltiplo, carcinoma renal, câncer de próstata, Síndrome da rejeição paciente-enxerto, entre outras. A talidomida possui um centro quiral e dois anéis amida em sua estrutura e é sintetizada como racemato, constituída por dois enantiômeros ativos: (+)-(R)- e (+)-(S)-talidomida. A talidomida racêmica apresenta duas formas polimórficas, alfa ( ) e beta ( ). Assim, a variabilidade observada em relação ao polimorfismo representa um ponto crítico se considerarmos o potencial de alteração de propriedades biofarmacêuticas em decorrência da predominância de um ou outro polimorfo. No Brasil o medicamento talidomida é fabricado exclusivamente pela FUNED – Fundação Ezequiel Dias, laboratório público do Estado de Minas Gerais que integra o Sistema Oficial de produção de Medicamentos do País. Neste contexto, este trabalho tem como principal objetivo a avaliação de características físicas, físico-químicas e tecnológicas dos polimorfos da talidomida, com ênfase nos ensaios de cristalização, dissolução, degradação e compressão. Os resultados deste trabalho contribuíram para um melhor entendimento da relação entre características cristalográficas e propriedades farmacêuticas, agregando uma base científica capaz de avaliar as diferenças existentes destes polimorfos e garantir o controle de qualidade adequado do produto final produzido em um Laboratório Oficial. Estes estudos contribuíram para o cumprimento de exigências regulatórias. / Thalidomide was widely prescribed between 1950 and 1960, in nearly 50 countries, as sedative and antiemetic for morning sickness during pregnancy. After the occurrence of serious problems of teratogenicity it was heavily controlled. Growing interest has been observed in recent years to identify and elucidate the anti-inflammatory, immunomodulatory and anti-angiogenic properties of thalidomide. In the same direction, clinical investigations have been conducted in patients with various diseases such as myeloma, renal carcinoma, and prostate cancer, among others. Thalidomide possesses a chiral center and two amide rings in its structure and is synthesized as racemate, consisting of two active enantiomers: (+)-(R)- and (+)-(S)-thalidomide. It is known that the racemic thalidomide has two polymorphic forms, alpha ( ) and beta ( ). Thus, the observed variability in relation to the polymorphism represents a critical point considering the potential of changes in biopharmaceutical properties due to the predominance of one of them. In Brazil thalidomide tablets are manufactured exclusively by FUNED – Fundação Ezequiel Dias, the public laboratory of the State of Minas Gerais, which integrates the Country's Official System of drug production. In this context, the objectives of this work are the assessment of physical characteristics, physicalchemical and technological properties of polymorphic forms of thalidomide, with emphasis on crystallization, dissolution, degradation and compression. The results of this work contributed to a better understanding of the relationship between characteristic crystallographic properties and pharmaceutical properties, aggregating a scientific basis to assess the differences of these polymorphs and ensure the appropriate quality control of the final product produced in an official laboratory. These studies contributed to compliance with regulatory requirements.
24

Fexofenadina : validação de métodos analíticos e estudo de fotoestabilidade

Breier, Ana Rita January 2007 (has links)
Este trabalho objetivou o desenvolvimento e validação de métodos analíticos para determinação de fexofenadina em cápsulas e comprimidos revestidos e o estudo de fotoestabilidade do fármaco. A determinação da faixa de fusão e a espectrofotometria no infravermelho permitiram identificar fexofenadina substância química de referência. Os métodos por cromatografia em camada delgada, espectrofotometria no ultravioleta (UV), cromatografia líquida de alta eficiência (CLAE) e eletroforese capilar (EC) foram utilizados para análise qualitativa do fármaco nas formas farmacêuticas. A determinação quantitativa foi realizada através da validação dos métodos por UV e CLAE para cápsulas e comprimidos e EC para cápsulas, avaliando-se os parâmetros descritos pelas guias de validação. Os métodos propostos não apresentaram diferença estatística para um nível de significância de 1%. O teste de dissolução foi desenvolvido e validado utilizando HCl 0,01 M como meio de dissolução, cestas a 100 rpm e pás a 75 rpm para cápsulas e comprimidos revestidos, respectivamente. Perfis de dissolução de cápsulas dos medicamentos referência e similar e comprimidos revestidos dos medicamentos referência, similar e genérico foram realizados e comparados através dos fatores de diferença e semelhança e da eficiência de dissolução e não apresentaram-se semelhantes. Estudo preliminar de estabilidade de fexofenadina frente à degradação ácida, alcalina, oxidativa, térmica e fotolítica mostrou a oxidação e a luz como fatores importantes de degradação. A cinética de fotodegradação de fexofenadina em soluções metanólica e aquosa demonstrou cinética de segunda ordem de reação. A estabilidade acelerada da fexofenadina foi realizada utilizando-se soluções metanólicas pH=6 e pH=11, as quais foram expostas às lâmpadas metal haleto e UVC 254 nm, havendo formação dos produtos majoritários, denominados PD-21 e PD-37, os quais foram isolados por cromatografia em coluna e CCD preparativa. A fotólise do pó de comprimidos e de comprimidos demonstrou haver formação dos mesmos produtos de degradação obtidos em solução. Os produtos foram identificados por ressonância magnética nuclear e espectrometria de massas como derivados benzofenona (PD-21) e isopropílico (PD-37) da fexofenadina. / The aim of this study was the development and validation of analytical methods to the determination of fexofenadine in capsules and coated tablets and the photostability study of the drug. The melting range determination and infrared spectrophotometry allowed fexofenadine standard reference identification. Methods of thin-layer chromatography (TLC), ultraviolet spectrophotometry (UV), high performance liquid chromatography (HPLC), and capillary electrophoresis (CE) were employed to the qualitative analysis of the drug in pharmaceutical formulations. The quantitative determination was performed through the validation of UV and HPLC for capsules and coated tablets, and CE for capsules, evaluating the guidances validation parameters. The proposed methods were not statistically different to a 1% significance level. The dissolution test was developed and validated using HCl 0,01 M as dissolution medium, basket at 100 rpm and paddle at 75 rpm to capsules and coated tablets, respectively. Dissolution profiles of reference and similar capsule products and reference, similar and generic coated tablets products were performed and compared using difference factor, similarity factor and the dissolution efficiency, showing not similarity. Preliminary stability study of fexofenadine through acid, alkaline, oxidative, thermal, and photolytic degradation shows sensibility to oxidation and light. The kinetic of photodegradation of fexofenadine in methanol and water solutions show second order kinetic of reaction. The accelerated stability was evaluated using fexofenadine methanolic solutions pH=6 and pH=11, which were exposed to a metal halide lamp and to a fluorescent lamp UVC 254 nm, giving two majority degradation products, assigned PD-21 and PD-37. The separation was carried out by HPLC and TLC. The products were isolated by column chromatography and preparative TLC techniques. The analysis of the powder of tablets and tablets, which were exposed to light, showed the same degradation products presented for solutions. The majority degradation products of fexofenadine were identified by nuclear magnetic resonance and mass spectrometry as a benzophenone derivative (PD-21) and isopropyl derivative (PD-37).
25

Fexofenadina : validação de métodos analíticos e estudo de fotoestabilidade

Breier, Ana Rita January 2007 (has links)
Este trabalho objetivou o desenvolvimento e validação de métodos analíticos para determinação de fexofenadina em cápsulas e comprimidos revestidos e o estudo de fotoestabilidade do fármaco. A determinação da faixa de fusão e a espectrofotometria no infravermelho permitiram identificar fexofenadina substância química de referência. Os métodos por cromatografia em camada delgada, espectrofotometria no ultravioleta (UV), cromatografia líquida de alta eficiência (CLAE) e eletroforese capilar (EC) foram utilizados para análise qualitativa do fármaco nas formas farmacêuticas. A determinação quantitativa foi realizada através da validação dos métodos por UV e CLAE para cápsulas e comprimidos e EC para cápsulas, avaliando-se os parâmetros descritos pelas guias de validação. Os métodos propostos não apresentaram diferença estatística para um nível de significância de 1%. O teste de dissolução foi desenvolvido e validado utilizando HCl 0,01 M como meio de dissolução, cestas a 100 rpm e pás a 75 rpm para cápsulas e comprimidos revestidos, respectivamente. Perfis de dissolução de cápsulas dos medicamentos referência e similar e comprimidos revestidos dos medicamentos referência, similar e genérico foram realizados e comparados através dos fatores de diferença e semelhança e da eficiência de dissolução e não apresentaram-se semelhantes. Estudo preliminar de estabilidade de fexofenadina frente à degradação ácida, alcalina, oxidativa, térmica e fotolítica mostrou a oxidação e a luz como fatores importantes de degradação. A cinética de fotodegradação de fexofenadina em soluções metanólica e aquosa demonstrou cinética de segunda ordem de reação. A estabilidade acelerada da fexofenadina foi realizada utilizando-se soluções metanólicas pH=6 e pH=11, as quais foram expostas às lâmpadas metal haleto e UVC 254 nm, havendo formação dos produtos majoritários, denominados PD-21 e PD-37, os quais foram isolados por cromatografia em coluna e CCD preparativa. A fotólise do pó de comprimidos e de comprimidos demonstrou haver formação dos mesmos produtos de degradação obtidos em solução. Os produtos foram identificados por ressonância magnética nuclear e espectrometria de massas como derivados benzofenona (PD-21) e isopropílico (PD-37) da fexofenadina. / The aim of this study was the development and validation of analytical methods to the determination of fexofenadine in capsules and coated tablets and the photostability study of the drug. The melting range determination and infrared spectrophotometry allowed fexofenadine standard reference identification. Methods of thin-layer chromatography (TLC), ultraviolet spectrophotometry (UV), high performance liquid chromatography (HPLC), and capillary electrophoresis (CE) were employed to the qualitative analysis of the drug in pharmaceutical formulations. The quantitative determination was performed through the validation of UV and HPLC for capsules and coated tablets, and CE for capsules, evaluating the guidances validation parameters. The proposed methods were not statistically different to a 1% significance level. The dissolution test was developed and validated using HCl 0,01 M as dissolution medium, basket at 100 rpm and paddle at 75 rpm to capsules and coated tablets, respectively. Dissolution profiles of reference and similar capsule products and reference, similar and generic coated tablets products were performed and compared using difference factor, similarity factor and the dissolution efficiency, showing not similarity. Preliminary stability study of fexofenadine through acid, alkaline, oxidative, thermal, and photolytic degradation shows sensibility to oxidation and light. The kinetic of photodegradation of fexofenadine in methanol and water solutions show second order kinetic of reaction. The accelerated stability was evaluated using fexofenadine methanolic solutions pH=6 and pH=11, which were exposed to a metal halide lamp and to a fluorescent lamp UVC 254 nm, giving two majority degradation products, assigned PD-21 and PD-37. The separation was carried out by HPLC and TLC. The products were isolated by column chromatography and preparative TLC techniques. The analysis of the powder of tablets and tablets, which were exposed to light, showed the same degradation products presented for solutions. The majority degradation products of fexofenadine were identified by nuclear magnetic resonance and mass spectrometry as a benzophenone derivative (PD-21) and isopropyl derivative (PD-37).
26

Controle de qualidade e avaliação das propriedades tecnológicas das formas polimórficas de talidomida / Quality control and evaluation of technological properties of polymorphic forms of thalidomide

Silva, Ana Paula Cappra January 2011 (has links)
A talidomida foi amplamente prescrita entre 1950 e 1960, em quase 50 países, como hipnosedativo não-barbitúrico e antiemético para indisposição matinal durante a gravidez, sendo em seguida fortemente controlada em função da ocorrência de sérios problemas de teratogenicidade. Nos últimos anos, vários esforços foram realizados no sentido de buscar identificar e elucidar as propriedades antiinflamatórias, imunomodulatórias e antiangiogênicas da talidomida. Na mesma direção, investigações clínicas foram conduzidas em pacientes com diversas doenças, como mieloma múltiplo, carcinoma renal, câncer de próstata, Síndrome da rejeição paciente-enxerto, entre outras. A talidomida possui um centro quiral e dois anéis amida em sua estrutura e é sintetizada como racemato, constituída por dois enantiômeros ativos: (+)-(R)- e (+)-(S)-talidomida. A talidomida racêmica apresenta duas formas polimórficas, alfa ( ) e beta ( ). Assim, a variabilidade observada em relação ao polimorfismo representa um ponto crítico se considerarmos o potencial de alteração de propriedades biofarmacêuticas em decorrência da predominância de um ou outro polimorfo. No Brasil o medicamento talidomida é fabricado exclusivamente pela FUNED – Fundação Ezequiel Dias, laboratório público do Estado de Minas Gerais que integra o Sistema Oficial de produção de Medicamentos do País. Neste contexto, este trabalho tem como principal objetivo a avaliação de características físicas, físico-químicas e tecnológicas dos polimorfos da talidomida, com ênfase nos ensaios de cristalização, dissolução, degradação e compressão. Os resultados deste trabalho contribuíram para um melhor entendimento da relação entre características cristalográficas e propriedades farmacêuticas, agregando uma base científica capaz de avaliar as diferenças existentes destes polimorfos e garantir o controle de qualidade adequado do produto final produzido em um Laboratório Oficial. Estes estudos contribuíram para o cumprimento de exigências regulatórias. / Thalidomide was widely prescribed between 1950 and 1960, in nearly 50 countries, as sedative and antiemetic for morning sickness during pregnancy. After the occurrence of serious problems of teratogenicity it was heavily controlled. Growing interest has been observed in recent years to identify and elucidate the anti-inflammatory, immunomodulatory and anti-angiogenic properties of thalidomide. In the same direction, clinical investigations have been conducted in patients with various diseases such as myeloma, renal carcinoma, and prostate cancer, among others. Thalidomide possesses a chiral center and two amide rings in its structure and is synthesized as racemate, consisting of two active enantiomers: (+)-(R)- and (+)-(S)-thalidomide. It is known that the racemic thalidomide has two polymorphic forms, alpha ( ) and beta ( ). Thus, the observed variability in relation to the polymorphism represents a critical point considering the potential of changes in biopharmaceutical properties due to the predominance of one of them. In Brazil thalidomide tablets are manufactured exclusively by FUNED – Fundação Ezequiel Dias, the public laboratory of the State of Minas Gerais, which integrates the Country's Official System of drug production. In this context, the objectives of this work are the assessment of physical characteristics, physicalchemical and technological properties of polymorphic forms of thalidomide, with emphasis on crystallization, dissolution, degradation and compression. The results of this work contributed to a better understanding of the relationship between characteristic crystallographic properties and pharmaceutical properties, aggregating a scientific basis to assess the differences of these polymorphs and ensure the appropriate quality control of the final product produced in an official laboratory. These studies contributed to compliance with regulatory requirements.
27

[en] INFLUENCE OF POLYMER DEGRADATION ON THE ANALYSIS OF POLYACRYLAMIDE BY TOTAL ORGANIC CARBON / [pt] INFLUÊNCIA DA DEGRADAÇÃO POLIMÉRICA NA ANÁLISE DE POLIACRILAMIDA POR CARBONO ORGÂNICO TOTAL

BRENDA DUARTE GRALHA 29 May 2023 (has links)
[pt] Os copolímeros de poliacrilamida desempenham um papel importante na recuperação avançada de petróleo, cuja utilização visa o aumento da produção de óleo. A avaliação do polímero na água produzida é, portanto, necessária para monitorar a operação do campo petrolífero e para questões ambientais. Entretanto, tal avaliação é desafiadora devido à complexidade da matriz e à possível degradação da macromolécula durante o processo. Entre os diferentes métodos para determinação de polímero, o carbono orgânico total (TOC, do inglês total organic carbon) é vantajoso em comparação com outros métodos reportados na literatura devido ao seu baixo custo, fácil operação e curto tempo de análise. Devido a isso, um método de análise por TOC foi desenvolvido para a determinação do teor de poliacrilamida, e a influência da salinidade, massa molar e dois tipos de degradação química (hidrólise e por Fe2+/O2) na quantificação do polímero por este método foram exploradas neste trabalho. Medidas reológicas, análises de ressonância magnética nuclear (RMN) e de espectroscopia de infravermelho (ATR-FTIR, do inglês Fourier-transform infrared with attenuated total reflectance) também foram realizadas com o intuito de avaliar a degradação. A quantificação do polímero na presença de diferentes teores de sal não foi afetada. De modo similar, as diferentes massas molares dos polímeros não afetaram os resultados das análises por TOC. O grau de hidrólise dos polímeros foi confirmado por 13C RMN e ATR-FTIR, enquanto medidas reológicas confirmaram a degradação por Fe2+/O2. Notavelmente, ambos os mecanismos de degradação investigados não impactaram a determinação de poliacrilamida. Para todos os fatores avaliados, os erros não ultrapassaram 8 por cento. Assim, os resultados obtidos destacam o método TOC como adequado e confiável para a determinação de poliacrilamida com boa exatidão, conferindo-lhe um potencial de aplicação para análises de amostras reais. / [en] Polyacrylamide copolymers play an important role in enhanced oil recovery (EOR), whose widespread use aims to improve oil production. Assessment of polymer in the produced water is thus required for monitoring the oilfield operation and for environmental concerns. However, this task is challenging due to the matrix complexity and the possible degradation of the macromolecule during the process. Among the different methods for polymer determination, total organic carbon (TOC) is advantageous in comparison to others reported in the literature because of its low cost, easy operation and short analysis time. Due to this, a TOC method was developed for the determination of polyacrylamide content, and the influence of salinity, molar mass, and two types of chemical degradation (by hydrolysis and Fe2+/O2) on the polymer quantification through this method were explored in this work. Rheological measurements, NMR and ATR-FTIR analyses were also carried out to evaluate the extent of degradation. The polymer quantification was not affected in the presence of different salt contents. Similarly, analyses of samples with different molar masses did not affect TOC results. The hydrolysis degree of the polymers was confirmed by 13C NMR and ATR-FTIR, while rheological measurements confirmed degradation by Fe2+/O2. Noticeably, both degradation mechanisms investigated did not impair polyacrylamide determination. For all factors evaluated, the errors were never greater than 8 percent. The results obtained highlight the TOC as a suitable and reliable method for the determination of polyacrylamide with good accuracy, showing its potential application in the analysis of real samples.
28

[en] AGING ASSESSMENT OF STRUCTURAL GFRP PROFILES THROUGH NON-DESTRUCTIVE DYNAMIC TESTING / [pt] AVALIAÇÃO DO ENVELHECIMENTO DE PERFIS ESTRUTURAIS DE PRFV UTILIZANDO ENSAIOS DINÂMICOS NÃO DESTRUTIVOS

JOAO PEDRO DE CASTRO TORRES 07 August 2023 (has links)
[pt] Nas últimas décadas, perfis pultrudados de polímeros reforçados com fibra (PRF) vêm despertando grande interesse na indústria civil devido a sua alta relação entre resistência e peso e sua aplicabilidade em ambientes agressivos. Apesar de apresentar grande resistência às intempéries, a degradação dos PRF foi notada após anos de exposição em campo. A utilização de ensaios não destrutivos (END) se mostra como uma boa alternativa para avaliar a integridade deste material, havendo especial interesse para controle de qualidade de baixo custo em campo. Dessa forma, este trabalho utilizou ensaios de vibração livre com duas técnicas de excitação por impulso para detectar danos em polímeros reforçados com fibra de vidro envelhecidos em câmaras com elevada temperatura, umidade e salinidade. Através da avaliação das frequências naturais e amortecimentos, foi observado o impacto das condições ambientais na integridade do material, resultado corroborado pela variação das propriedades elásticas obtidas através da resposta dinâmica acústica. / [en] In the last decades, pultruded profiles of fiber-reinforced polymers (FRP) have been attracting great interest in the civil industry due to their high strength-to-weight ratio and their applicability in aggressive environments. Despite showing great resistance to weathering, the degradation of FRP was noticed after years of exposure in the field. The use of non-destructive techniques (NDT) has been shown to be a good alternative to evaluate the integrity of this material, with special interest for low-cost quality control in the field. Thus, this work used free vibration tests with two impulse excitation techniques to detect damage in glass fiber reinforced polymers aged in chambers with high temperature, humidity and salinity. Through the evaluation of natural frequencies and damping, the impact of environmental conditions on the integrity of the material was observed, a result corroborated by the variation of elastic properties obtained through the acoustic dynamic response.
29

[en] INFLUENCE OF FIBER DEGRADATION ON MECHANICAL BEHAVIOR OF REINFORCED SOILS / [pt] INFLUÊNCIA DA DEGRADAÇÃO DE FIBRAS NO COMPORTAMENTO MECÂNICO DOS SOLOS REFORÇADOS

FERNANDA PECEMILIS DALLA BERNARDINA 20 December 2019 (has links)
[pt] O presente estudo experimental apresenta o comportamento mecânico e a durabilidade de compósitos de solo arenoso reforçado com fibras de polipropileno e de fibras vegetais de coco, sisal e curauá, aleatoriamente distribuídas, submetidos ao envelhecimento natural, com o objetivo de estudar a sua aplicação em obras geotécnicas. O programa experimental consistiu na execução de ensaios triaxiais drenados nas amostras de areia pura, areia-fibra no tempo zero (amostras de controle) e nos compósitos expostos por um período máximo de 8 meses, com o objetivo de avaliar a durabilidade dos compósitos. Foram realizados ensaios de tração direta nas fibras vegetais sem degradação e nas fibras utilizadas como reforço em compósitos expostos ao ambiente externo e ao tempo, localizadas nas profundidades de 75 e 125 cm. Para um melhor entendimento da variação dos resultados obtidos, os ensaios triaxiais e de tração foram executados nos intervalos de tempo: 0, 60, 120 e 240 dias. Foi possível observar que todos os compósitos expostos apresentaram queda na resistência de cisalhamento, em relação às amostras de controle, inclusive os reforçados com fibra de polipropileno. Os compósitos reforçados com fibra de coco apresentaram baixa degradação, se comparados com as amostras reforçadas com outras fibras vegetais. Quanto aos ensaios de tração, a fibra de curauá apresentou as maiores resistências à tração inicial e final, após os 8 meses, porém foi a fibra que mais sofreu degradação durante o período em exposição, sofrendo grandes per-das de resistência. Todas as fibras analisadas apresentaram degradação maior na profundidade de 75 cm. / [en] The present experimental study presents the mechanical behavior and the du-rability of composites of sandy soil reinforced with polypropylene fibers and vegetal fibers of coconut, sisal and curauá, randomly distributed, submitted to the natural aging, with the objective of studying their application in earthworks. The experimental program consisted in the execution of triaxial tests in the sand, sand-fiber samples at zero time (control samples) and in the exposed composites for up to 8 months, in order to evaluate the durability of the composites. Direct tensile tests were done on the non-degraded natural fibers and on the fibers used as reinforcement in samples exposed to the external environment and to the time, located at depths of 75 and 125 cm. For a better understanding of the variation of the obtained results, the triaxial and tensile tests were performed in the time intervals: 0, 60, 120 and 240 days. It was possible to observe that all exposed composites presented a drop in shear strength, in relation to the control samples, inclusive those reinforced with polypropylene fiber. The composites reinforced with coconut fiber presented low degradation when compared with the samples forced with other vegetable fibers. Regarding the tensile tests, the curaua fiber showed the greatest resistance to the initial and final traction, after 8 months, but it was the fiber that suffered the most degradation during the exposure period, suffering great losses of resistance. All the analyzed fibers presented degradation greater in the depth of 75 cm.
30

[pt] CARACTERIZAÇÃO MORFOLÓGICA, QUÍMICA E TÉRMICA DE SUCATA ELETRÔNICA VISANDO DEFINIR UMA ROTA PARA RECUPERAÇÃO DE MATERIAIS / [en] MORPHOLOGICAL, CHEMICAL AND THERMIC CHARACTERIZATION OF EWASTE IN ORDER TO DEFINE A ROUTE FOR MATERIALS RECOVERY

JULIANA SANTOS SETTE DE OLIVEIRA 09 February 2021 (has links)
[pt] O crescimento da produção de resíduos sólidos devido a evolução tecnológica, principalmente nos países em desenvolvimento, vem apresentando-se de maneira acelerada. Esta evolução acarreta na produção de novos produtos eletrônicos mais atualizados e, cada vez mais sofisticados quanto à composição química, com novas funcionalidades, tornando os antigos dispositivos obsoletos. O consumo exarcebado destes novos produtos contribui para um problema que ganha cada vez mais relevância no cenário mundial, o acúmulo de lixo eletrônico de origem urbana. O presente estudo contemplará como matéria prima amostras de placas de circuito impresso de computadores, conhecidas como PCIs, que são um padrão de barramentos, destinado a conectar periféricos à placa-mãe. Tendo em vista que nestes resíduos os teores de metais são tipicamente superiores àqueles de reservas naturais, torna-se interessante buscar rotas que viabilizem a reciclagem desses resíduos com a concomitante recuperação de constituintes de interesse ou concentração de precursores em distintos grupos para a posterior recuperação de metais. Nesta abordagem, foram realizadas análises termogravimétricas para acompanhar as melhores condições de processo e caracterização do material e produtos através de MEV/EDS. Assim, este material, tipicamente constituído por material orgânico (ex: plásticos como PVC) e constituintes inorgânicos (ex: metais e ligas metálicas), será submetido a um processamento térmico em forno tubular a 350 graus C em atmosfera inerte, seguido de etapas de concentração. A partir de 300 graus C a perda de massa se mantém constante, em torno de 30 por cento, e nas seguintes etapas aplicadas, 15 por cento da amostra total em constituintes metálicos com alto valor agregado, no caso Cu, Ni e Au, podem seguir para recuperação. / [en] The production of solid residues due to technological development has been increasing fast, mainly in developing countries. This growth leads to the manufacture of improved electronic products with varied functions, which not only are better versions of the old ones but also more sophisticated in their chemical compounds. The excessive consumption of the new devices contributes to an issue which has been increasing internationally: the accumulation of electronic waste. The raw material used in this study are samples of computer printed circuit boards (PCBs), which are a bus pattern that connects peripherals to the motherboard. Since the metal content in these residues are typically more elevated than in the ones located in natural reserves, it is interesting to find ways to recycle those residues while recovering components of interest or precursor concentrations in distinct groups for later metal recovery. Thermogravimetric analysis were performed on this approach in order to observe the best conditions of the process and the characterization of material and products was through SEM/EDS. Thus, this material, typically composed by organic material (such as plastic or PVC) and inorganic constituents (such as metals and alloys), undergoes a thermal processing in tubular furnace at 350 C degrees in inert atmosphere, followed by the concentration steps. The mass loss is constant from 300 C degrees on, around 30 percent. In the following steps, 15 percent of the total sample presents metallic components with high added value, such as Cu, Ni and Au, may be recovered.

Page generated in 0.0611 seconds