• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2304
  • 155
  • 150
  • 150
  • 148
  • 109
  • 35
  • 35
  • 24
  • 17
  • 17
  • 12
  • 7
  • 5
  • 2
  • Tagged with
  • 2362
  • 1247
  • 1039
  • 886
  • 534
  • 523
  • 493
  • 433
  • 425
  • 347
  • 234
  • 192
  • 180
  • 166
  • 163
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
381

O uso de agentes desinfetantes em materiais de moldagem: sua influência na estabilidade dimensional linear

Silva, Sávio Marcelo Leite Moreira da 19 February 2003 (has links)
O objetivo deste trabalho foi avaliar a estabilidade dimensional das siliconas de condensação pesada e leve para moldagem odontológica, quando imersas em solução desinfetante por 10 e 20 minutos, relacionando a importância da biossegurança no manuseio destes materiais. Os materiais de moldagem testados foram: Optosil Confort e Xantopren VL Plus; e as soluções desinfetantes foram o hipoclorito de sódio a 1% (Solução de Milton) e o glutaraldeído a 2% (Glutaron II). Impressões foram obtidas através de moldeiras perfuradas de aço inoxidável, de acordo com a especificação n.º 19 da ADA, perfazendo um total de 50 moldagens, que foram executadas pela técnica em passo único, de acordo com as especificações do fabricante. Para assegurar a completa polimerização o material foi removido após 7 minutos e submetido à imersão nas soluções desinfetantes nos tempos determinados, sendo um grupo controle representado por moldes sem imersão. Depois de removidos das soluções, os corpos de prova foram lavados em água corrente por 15 segundos, secos e medidos 3 vezes cada para registro da média, usando um microscópio óptico, com precisão de 0,001 mm. A análise de variância a dois critérios, com nível de significância de 5%, mostrou que as diferenças nas dimensões lineares da silicona testada não são estatisticamente significantes (p>0,05) após sua imersão em solução de hipoclorito de sódio a 1% e glutaraldeído a 2% até 20 minutos. Os resultados indicaram que a combinação testada de material de moldagem e solução desinfetante pode seguramente ser empregada na clínica odontológica para o controle de infecção e segurança da equipe de saúde bucal. / The purpose of this study was to evaluate the dimensional stability of condensation silicone rubber heavy and light body after immersion in disinfectant solution for 10 or 20 minutes. The impression materials were Optosil Confort e Xantopren VL Plus and the disinfectants solutions were 1% sodium hypochlorite and 2% glutaraldehyde. Impressions were made on a perforated stainless steel tray, according to the American Dental Association specification No. 19, performed a total of 50 samples. The double mixing method (one time, two viscosities) was used. Impressions were removed from the roulette block after 7 minutes to ensure complete polymerization and then immersed in the solutions. Impressions with no treatment composed the control group. After these steps, impressions were taken out the solution and rinsed in running water and air dried. Three dimensional measurements were calculated, using an optic microscope graduated at 0,001 mm. The two- way ANOVA indicated no differences (p>0.05) for any combination between variables. The results have shown that the solution studied can be safety used to disinfect condensation silicon in clinical prosthodontic procedures.
382

Fidelidade de Troquéis de Gesso, Obtidos a Partir de Moldes de Vários Elastômeros, Através de Duas Diferentes Técnicas de Moldagem.

Marchese, Marco Polo 03 August 1999 (has links)
As restaurações fixas são rotineiramente fabricadas sobre um modelo de gesso, obtidos a partir do molde de um dente preparado. A precisão na adaptação destas é influênciada diretamente pelas propriedades dos materiais de moldagem empregado. Qualquer que seja o elastomêro eleito, o método mais confiável para se avaliar o seu desempenho em conduzir a modelos de gesso fiéis, parece ser aquele no qual é empregado um coroa-padrão que se adapta com precisão a um troquel apropriado. Este trabalho tem por objetivo avaliar se dentre as técnicas da dupla moldagem (com alívio de 1 e 2 mm) e a do casquete, existe uma mais adequada ou se ambas apresentam adequações suficiente e semelhantes. Foram empregados cinco elastômeros (Express, Impregum F, Imprint, Permlastic e President), os moldes foram obtidos empregando-se um dispositivo de moldagem idealizado por ARAÚJO e JÖRGENSEN6 e vazados com gesso especial tipo IV (Vel-Mix). A coroa-padrão foi posicionada nos troquéis e avaliada, quanto à sua precisão de adaptação, em um microscópio de medição de profundidade. Os resultados estatístico mostraram que a técnica do casquete apresentou melhores resultados para os materiais Impregum F e Imprint, vindos a seguir o Express e o President (ambos com alívio de 2 mm) e o Express (alívio de 1 mm); o Permlastic e o Express, na técnica do casquete, apresentaram piores resultados que os anteriores, mas semelhantes entre si, sendo o President (casquete) semelhante à este último; o President (alívio de 1 mm), foi o que apresentou pior resultado. / Fixed restorations are usually produced on gypsum dies obtained from a prepared tooth mold and its precise adaptation is directly influenced by the properties of the impression materials. The objective of this study was to compare the performance of five impression materials and different methods of impression. Materials were tested using the putty-wash method being the first impression realeased in 1 or 2 mm (for Express and President) and the individual resin tray shell (Express, Impregum F, Imprint, Permlastic e Predident). The deviced used by ARAÚJO; JÖRGENSEN6 and the Vel-Mix (type IV) gypsum were used. The adaptation of one standard-crown to the dies was analysed with a depth measuring microscope. The results showed that Impregum F and Imprint (with a shell) gave the best results, followed by Express and President (putty/wash – 2 mm) and Express (putty/wash – 1 mm). The results with Permlastic and Express (shell) were less satisfactory and the difference between them wasn’t statistically significant. Express (shell) was not statistically different from the President (shell), and the worse result was given by the President (putty/wash - 1 mm) when compared to all the others.
383

Acompanhamento longitudinal do sucesso das próteses suportadas por implantes osseointegrados do sistema NAPIO / Longitudinal follow-up of NAPIO osseointegrated implants in function for 2 years

Correia, Sylvia Maria Bastos 14 December 1999 (has links)
Nos últimos anos, têm sido possível a reposição de dentes ausentes, utilizando-se os implantes osseointegrados como suporte para próteses. A eficácia clínica desta terapia por implantes foi bem estabelecida por uma miríade de trabalhos longitudinais com alto índice de sucesso e suprindo critérios previamente estabelecidos. Nestes estudos, observou-se concentração das falhas desde a segunda cirurgia até o primeiro ano de instalação da prótese. Para a realização deste estudo foi avaliado o sucesso de implantes do sistema NAPIO (Núcleo de Apoio à Pesquisa de Implantes Odontológicos) confeccionados em titânio grau I e previamente tratados por ataque ácido. Foram inseridos 371 implantes em 109 pacientes suportando 135 próteses unitárias, parciais, protocolo e sobre-dentaduras, durante 2 anos. A distribuição por sexo foi de 39.4% de homens e 60.6% de mulheres com idade variando de 17 a 82 anos. Os implante foram avaliados clinicamente através da profundidade de sondagem, nível de inserção, presença de placa, edema, supuração, alteração na coloração e radiograficamente pela técnica do cone longo padronizando a posição com o registro da mordida em resina acrílica. Os implantes foram classificados como sucesso se suprissem os critérios de SMITH; ZARB186. O índice de sucesso na maxila foi de 90.21% e 99.25% e na mandíbula de 95.90% e de 100%, respectivamente, para os implantes e as próteses, compatível com os relatados na literatura. Detectou-se concentração das falhas até a segunda fase cirúrgica, com mais de 75% destas localizadas na maxila e superior a 55% na mandíbula. Todos os implantes que falharam apresentaram comprimento igual ou inferior a 10 mm. As radiografias foram digitalizadas e medidas no programa Sigma Scan Pro, obtendo-se a perda óssea de 0.95 na face mesial, 1.03 na face distal e a média de 0.99 durante dois anos. A inflamação do tecido peri-implantar, presença de placa e sangramento a sondagem reduziram significativamente nos quatro exames. A medida de profundidade de sondagem e nível de inserção também diminuíram, porém de forma insignificante. A complicação, mais freqüente, da prótese foi o reaperto do parafuso da prótese, seguida da fratura deste. Os pacientes aferiram notas subjetivas, em relação ao conforto, estética e função da prótese suportada por implantes e a média das notas foi sempre superior a 9 na maxila e mandíbula. A partir dos dados obtidos com parâmetros periodontais, percentual de sucesso e falha, perda óssea mensurada radiograficamente, como também das complicações das próteses, concluiu-se que existe compatibilidade com os dados da literatura atestando a efetividade do sistema de implantes avaliado durante os dois primeiros anos . / Replace of missing teeth by osseointegrated implants has become an accepted treatment modality in clinical dentistry. The clinical efficacy of implant therapy has been demonstrated through a myriad of long-term studies following an established criteria for success and showing high survival rates. In those studies most of the failures were concentrated at the second stage surgery and in the first year following the insertion of the prostheses. In the present study , the success of 371 implants of the NAPIO (Center of Supporting Research in Dental Implants) implant system placed in function for 2 years were evaluated. These implants were used to support 135 single units and a variety of fixed and removable prothesis placed in 109 patients presenting partial and complete edentulism. The gender distribution encompassed 43% of males and 66% of females. The age range was between 17 and 82 years old. The implants were made of titanium grade I and acid etched. Clinical and radiografic evaluation were done every 6 months in the first year and then once a year for 2 years. The clinical evaluation was performed using several known periodontal parameters such as, probing depth, attachment level, presence of plaque, suppuration, edema and color alteration. For radiographic assessment, a standardized technique using an individually customized film holder with acrylic resin was used. The implants were evaluated using the success criteria described by SMITH; ZARB186. The success index for the mandible was 95.90% and for the maxilla 90.21% reflecting a clinical efficacy similar to others osseointegrated implant systems. Of the failing implants, 77% of those placed in the maxilla and 45.5% of the ones placed in the mandible were detected at second surgery, and were all of short length. The radiographs were digitized and measured using the software Sigma Scan Pro 4 (Jandel Scientifics) and the bone loss calculated for every time point. Results demonstrated an overall bone loss of 0.99 mm during 2 years. There were very little changes in probing depth and attachment level during the first 2 years and, almost no changes were found using parameters to access inflammation of the peri-implant tissue, presence of plaque, edema and bleeding on probing. The most frequent complication found in the prostheses assessment was loosening and fracturing of the retaining screw. The grades of confort, esthetics and function of the prostheses were assessed by the patients and the results were superior to 9.4 attesting the efficacy of the treatment from the patients point of view. It was concluded that the results found for clinical parameters, implants success, bone loss measured radiografically and complications found in the prosthesis during the first two years of follow-up were in agreement with results presented in the literature for other osseointegrated implant systems.
384

Efeito do acréscimo de nano-hidroxiapatita nas propriedades físico-químicas, mecânicas e antibiofilnme do cimento portland com óxido de zircônio /

Trindade Junior, Adinael. January 2014 (has links)
Orientador: Juliana Maria Guerreiro Tanomaru / Banca: Iara Teresinha Correia Silva Sousa / Banca: Elisabeth Loshchagin Pizzolitto / Resumo: A substituição do óxido de bismuto por óxido de zircônio (ZrO2) e o acréscimo de hidroxiapatita nanoparticulada (HAn) podem favorecer propriedades do Cimento Portland (CP). Este estudo objetiva comparar propriedades físico-químicas, mecânicas e antibiofilme do CP com ZrO2, acrescido de HAn. Os materiais avaliados foram: G1 - MTA Angelus; G2 - CP/ZrO2; G3 - CP/ZrO2/HAn10%; G4 - CP/ZrO2/HAn20%. O pH foi analisado em phmetro digital, a solubilidade pela perda de massa e o tempo de presa pelo teste de Gilmore. A resistência à compressão foi avaliada por meio de ensaio mecânico. Amostras dos materiais foram radiografadas com uma escala de alumínio para análise da radiopacidade. Para a avaliação antibiofilme os materiais foram colocados em contato com biofilme de E. faecalis formado em blocos de dentina, e avaliado pela contagem de unidades formadoras de colônias (UFCmL-1). Os resultados foram submetidos aos testes ANOVA e Tukey com 5% de significância. G2 e G3 apresentaram pH mais elevado. Maior solubilidade foi observada para G3 e G4. O tempo de presa inicial foi menor para G1 e o tempo de presa final para G3. Todos os materiais apresentaram radiopacidade superior a 3 mm Al. A resistência à compressão foi maior para G2 nos períodos avaliados. Nenhum cimento foi capaz de neutralizar completamente o biofilme bacteriano, mas G3 e G4 proporcionaram maior redução bacteriana. Conclui-se que a associação CP/ZrO2 e CP/ZrO2 com 10% de HAn apresentam propriedades físico-químicas adequadas e que o acréscimo de HAn melhora a atividade antibiofilme de E faecalis. / Abstract: The bismuth oxide replacement by zirconium oxide (ZrO2) and the addition of hydroxyapatite nanoparticle may improve the Portland Cement (PC) properties. This study aimed evaluate the physicochemical, mechanical and antibiofilm of Enterococcus faecalis properties of Portland Cement (PC) association with zirconium oxide (ZrO2), added with hydroxyapatite nanoparticles (HAn). The analised materials were: G1 -MTA Angelus; G2 - PC/ZrO2; G3 - PC/ZrO2/HAn10%; G4 - PC/ZrO2/HAn20%. The pH was measure with a digital phmeter and the solubility by the weight loss. Setting time was assayed by Gilmore needle. Compressive strength was tested in universal testing machine. Materials samples were radiographed alongside an aluminum (Al) step wedge. For the antibiofilm test, the samples were place in direct contact with E. faecalis biofilm over dentine blocks, and assessed by colony forming units (CFU mL-1). The results were submitted to ANOVA and Tukey's test at 5% significance. G2 and G3 showed the higher pH in both experimental periods. Bigger solubility was noted for G3 and G4. The initial setting time was shorter for G1, and the final setting time for G3 and G4. All material presented radiopacity greater than 3 mmAl. Compressive strength was better for G2 in both experimental periods. No cement was able to completely neutralize the bacterial biofilm, however G3 and G4 exhibited higher bacteria reduction. The PC/ZrO2 and PC/ZrO2 with HAn 10% association presented the better physicochemical and mechanical properties, and the association with HAn improves the E. faecalis antibiofilm activity. / Mestre
385

Caracterização de um silicone de adição experimental contendo diferentes partículas de reforço / Influence of different particle fillers in properties of an experimental polyvinylsiloxane

Meincke, Débora Könzgen 21 November 2014 (has links)
Submitted by Fabiano Malheiro (fabianomalheiro22@hotmail.com) on 2017-05-26T13:17:26Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Caracterização de um silicone de adição experimental contendo diferentes partículas de reforço.pdf: 1199786 bytes, checksum: d9b686b8ec892d59f40f1dc6fe9c4498 (MD5) / Made available in DSpace on 2017-05-26T13:17:26Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Caracterização de um silicone de adição experimental contendo diferentes partículas de reforço.pdf: 1199786 bytes, checksum: d9b686b8ec892d59f40f1dc6fe9c4498 (MD5) Previous issue date: 2014-11-21 / Sem bolsa / Silicone por adição ou polivinilssiloxanos (VPS), são materiais de moldagem elastoméricos caracterizados principalmente pela precisão de impressão, em termos de reprodução de detalhes e precisão dimensional, pré-requisito essencial para uma boa moldagem, e consequentemente uma boa restauração indireta. Assim, o objetivo deste estudo foi avaliar qualitativamente a incorporação de diferentes partículas de reforço em um silicone de adição experimental (VPS) em duas concentrações diferentes, 20% e 40%. O método de depósito foi baseado na adição de partículas de reforço na matriz do polivinilssiloxano para melhorar as propriedades físicas e mecânicas. Para isso, o estudo foi desenvolvido em três fases, que incluem: (i) preparação do polivinilssiloxano experimental; (ii) incorporação de partículas de reforço em diferentes concentrações: a) 20% de partícula de reforço, b) 40% de partículas de reforço; (iii) caracterização do polivinilssiloxano através da análise de resistência à tração, reprodução de detalhes, dureza shore A, recuperação elástica e MEV. Quanto aos resultados obtidos o AE 40% e PAH 40% obtiveram sua habilidade de cópia prejudicada pela alta viscosidade, e apresentaram maior valores de dureza shore A e de resistência a tração. A recuperação elástica não foi estatisticamente significativa. Por conseguinte, características como morfologia, granulometria e quantidade de partículas inorgânicas na matriz polimérica de um polivinilssiloxano são responsáveis pela caracterização das propriedades do material. / Addition silicones or polyvinylsiloxanes are elastomeric impression materials characterized mainly by printing accuracy in terms of detail reproduction and dimensional accuracy, essential pre-requisites for a good impression and consequently a good indirect restoration. So, the aim of the study was to evaluate qualitatively the incorporation of different filler particles on an experimental polyvinylsiloxane (VPS) at two different concentrations, 20% and 40%. An experimental VPS was developed, and on this were deposited different kinds of filler particles. The deposit method was based on adding filler particles onto a VPS matrix to improve physical and mechanical properties. For this, the study was developed in three stages: (i) preparation of an experimental VPS; (ii) filler particle incorporation in different concentrations, (a) 20% filler particle and (b) 40% filler particle; (iii) silicone characterization through analysis of strength tensile, detail reproduction, shore A hardness, elastic recovery and SEM. The results show that AE 40% and PAH 40% had copy ability hampered by high viscosity, and they present the highest shore A hardness and strength tensile values. The elastic recovery was not statistically significant. Therefore, characteristics such as morphology, particle size and amount of filler particles in a VPS matrix are responsible for characterizing the properties of the material.
386

Avaliação da Taxa de Sobrevivência e da Condição Periimplantar em Pacientes Periodontalmente Comprometidos: Estudo Transversal de Implantes em Função Por um Período de 10 a 18 Anos

LOPES, G. D. R. S. 08 August 2017 (has links)
Made available in DSpace on 2018-08-01T23:26:01Z (GMT). No. of bitstreams: 1 tese_11180_Dissertacao Mestrado Versão Impressão Guilherme Scalzer.pdf: 635625 bytes, checksum: de6fa8a651fa5a86a4368f93e4daea62 (MD5) Previous issue date: 2017-08-08 / Apesar da alta taxa de sobrevivência dos implantes dentários, a região peri-implantar pode apresentar quadros inflamatórios conhecidos como mucosite peri-implantar, que quando não tratados podem evoluir para peri-implantite. Ambas as patologias são inflamações induzidas pelo biofilme de maneira similar a etiopatogenia das doenças periodontais. O objetivo do estudo foi avaliar a taxa de sobrevivência e o perfil peri-implantar em indivíduos com histórico de doença periodontal, pois eles poderiam ser mais suscetíveis às doenças inflamatórias peri-implantares. Sendo assim, o presente estudo avaliou, clínica e radiograficamente, 58 implantes instalados em sete indivíduos, tratados por uma mesma equipe de profissionais, em uma clínica privada da cidade de Vitória/ES, entre os anos de 1997 e 2005, de modo que no momento da coleta de dados todos os implantes apresentavam pelo menos 10 anos em função. Foram avaliadas as seguintes variáveis relacionadas aos implantes: índice de placa visível (IPV), índice de sangramento gengival marginal (ISGM), profundidade de sondagem peri-implantar (PSP), sangramento à sondagem peri-implantar (SSP) e nível ósseo marginal (NOM), a fim de relacioná-las à sobrevivência e à classificação dos implantes. Os resultados mostraram um índice de sobrevivência de 100% e a classificação dos 58 implantes se deu da seguinte forma: 11 (18,9%) foram classificados como saudáveis e 12 (20,7%) como clinicamente estáveis. Os outros 35 implantes (60,4%) apresentaram algum tipo de inflamação peri-implantar, sendo 20 deles (34,5%) diagnosticados com mucosite e 15 (25,9%) com peri-implantite. Dentre as variáveis estudadas, diferenças estatisticamente significativas foram observadas somente para a localização do implante (p<0,01) e para o índice de sangramento gengival marginal (ISGM) (p=0,03). A maioria dos implantes instalados em maxila (85,7%) foram classificados com algum tipo de inflamação peri-implantar (mucosite ou peri-implantite). Para os implantes que apresentaram escore 1 para o ISGM a maioria (75,0%) também foi classificada com algum tipo de inflamação peri-implantar (mucosite ou peri-implantite). O estudo demostrou que implantes instalados em pacientes periodontalmente comprometidos podem apresentar altas taxas de sobrevivência em longo prazo. Porém, apesar dessa alta taxa de sobrevivência, a maioria dos implantes foi classificada com algum tipo de inflamação peri-implantar.
387

Avaliação do comportamento biológico de materiais endodonticos utilizando duas linhagens celulares

Camargo, Samira Esteves Afonso [UNESP] 30 July 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:30:59Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-07-30Bitstream added on 2014-06-13T20:01:19Z : No. of bitstreams: 1 camargo_sea_dr_sjc.pdf: 640663 bytes, checksum: 4cae675acd74b1d6da77301be420d2d3 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Alguns materiais endodônticos são capazes de liberar componentes tóxicos que podem interagir com o tecido pulpar e/ou periapical. A proposta deste estudo foi avaliar in vitro, em nível molecular, os possíveis efeitos citotóxicos e genotóxicos de materiais endodônticos sobre cultura de células pulpares humanas transformadas (tHPC) e fibroblastos V79. Os espécimes de hidróxido de cálcio (HC, Hydro C, Dentsply, Brasil), MTA cinza (Angelus, Brasil), MTA branco (Angelus, Brasil) e polímero da mamona (POM, Poliquil, Brasil) foram misturados e colocados em meio de cultura (91,6 mm2 superfície /ml) por 24h em 37°C. Vitrebond (3M ESPE) foi utilizado como grupo controle positivo. As tHPC foram expostas aos extratos e diluições dos materiais e após 24h, a sobrevivência celular foi determinada pelo teste de cristal violeta. A liberação de espécies reativas de oxigênio (ROS) em tHPC foram mensuradas após 1h de exposição aos materiais. ROS foram detectados pelo manchamento das células com H2DCF-DA e a fluorescência foi mensurada por citometria de fluxo (FACS). A genotoxicidade foi determinada pela formação de micronúcleos em células V79 após 24h de exposição ao HC, MTA cinza, POM e etilmetano sulfanato (controle positivo). O atraso do ciclo celular normal de células V79 foi analisado, após a exposição ao MTA cinza, HC, POM e TEGDMA (controle positivo) por FACS. As diferenças entre a taxa de sobrevivência celular, fluorescência, número de micronúcleos e distribuição de células no ciclo celular foram estatisticamente analisadas pelo teste de Mann-Whitney-U (p<0,05). A citotoxicidade em relação ao grupo controle decresceu na seguinte ordem Vitrebond > HC > MTA branco = MTA cinza >>> POM. O POM causou indução da proliferação celular, enquanto o HC diminuiu a sobrevivência celular significativamente (p<0,05)... / Endodontic materials could release toxic components that may interact with pulp or periapical tissues. The purpose of this study was evaluated the cytotoxicity and genotoxicity of endodontic materials on transformed human pulp-derived cells (tHPC) and fibroblasts V79. Specimens of calcium hydroxide (Hydro C, Dentsply- Brazil), MTA gray (Angelus-Brazil), MTA white (Angelus-Brazil), and castor oil bean (COB, Poliquil-Brazil) were mixed and subsequently extracted in culture medium (91,6 mm2 sample surface/ml) for 24h at 37°C. Vitrebond (3M ESPE) served as a positive control. Exposure of tHPCs to dilutions of the extracts was stopped after 24h, and cell survival was determined photometrically after staining the cells with crystal violet. The generation of reactive oxygen species (ROS) was determined after a 1h exposure of the cells to extracts. ROS were detected by staining the cells with H2DCF-DA, and fluorescence was measured by flow cytometry (FACS). The genotoxicity as indicated by the formation of micronuclei was determined in V79 cells after a 24h exposure period. The modification of the normal cell cycle was analyzed by FACS. Differences between cell survival rates and fluorescence levels were statistically analyzed (Mann-Whitney-U test, p<0.05). The ranking of the cytotoxic effects based on EC50 values was as follows: Vitrebond > Hydro C > MTA gray = MTA white >>> COB. Extract of COB even induced cell proliferation, but Hydro C decrease cell survival in a doserelated manner. ROS production was not detected with any experimental material (p>0,05). Vitrebond increased ROS production about sevenfold (p<0,05). The increase in the number of micronuclei and cell cycle delay in V79 cells were not detected with any experimental material in relation to control group. COB and MTA (gray and white) did not negatively influence cell viability and ROS production. HC presented cytotoxic... (Complete abstract, click electronic access below)
388

Biocompatilibidade in vivo de implantes de titânio submetidos ao processo biomimético

Machado, Ana Cristina Posch [UNESP] 13 February 2002 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:30:59Z (GMT). No. of bitstreams: 0 Previous issue date: 2002-02-13Bitstream added on 2014-06-13T19:01:08Z : No. of bitstreams: 1 machado_acp_dr_sjc.pdf: 3944406 bytes, checksum: 12231bfae0b05fe47117cdc9fa22d4f3 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Propõe-se neste estudo avaliar a neoformação óssea no interior dos poros e ao redor de implantes porosos de titânio, submetidos ao processo biomimético modificado, inseridos em tíbias de coelhos. Foram confeccionados 180 implantes de titânio puro grau 2, com porosidade controlada, obtidos por meio da metalurgia do pó. Noventa implantes foram pré-tratados com solução de NaOH à 130ºC/1h, submetidos à temperatura de 200ºC/1h e posteriormente imersos em fluido corpóreo simulado modificado por 14 dias. Os implantes foram inseridos em 30 coelhos sendo que cada um recebeu 3 implantes tratados na tíbia esquerda e 3 sem tratamento na tíbia direita. Os animais foram sacrificados em 15, 30 e 45 dias após a cirurgia e os fragmentos das tíbias contendo os implantes foram submetidos à análise histológica, histomorfométrica e teste mecânico de cisalhamento. A análise microestrutural das amostras foi realizada por microscopia eletrônica de varredura (MEV), espectrometria por energia dispersiva de raios X (EDS) e espectroscopia Raman e a avaliação da neoformação óssea por microscopia de luz (MO) e MEV, comparando implantes sem tratamento com aqueles submetidos ao tratamento biomimético. O EDS indicou que a superfície do implante após o tratamento biomimético continha principalmente cálcio (Ca) e fósforo (P) além da presença de titânio. A Espectroscopia Raman do implante de titânio, após o tratamento biomimético, indicou pico característico e de grande magnitude a 960cm-1 devido à formação de uma camada de hidroxiapatita. As imagens ao MO e MEV demonstraram que houve neoformação óssea na interface osso-implante e no interior dos poros, inclusive naqueles mais centrais. Observou–se que a porcentagem média de neoformação óssea nos implantes tratados nos três tempos de sacrifício foi maior do que nos implantes não tratados, sendo observada diferença... / The purpose of this study is to define the coating on porous titanium implants submitted to modified biomimetic process and to evaluate bone neoformation inside the porous and around these implants when inserted in tibiae of rabbits. One hundred and eighty pure titanium implants, fabricated by powder metallurgy, were made. Ninety implants were pretreated with NaOH solution at 130ºC/1h and submitted to the temperature of 200ºC/1h and immersed in modified simulated body fluid for 14 days. The implants were inserted in 30 rabbits; each rabbit received 3 treated implants in the left tibia and 3 untreated implants in the right tibia. The animals were sacrificed after 15, 30, and 45 days of surgery and the tibia fragments containing the implants were submitted to histological and histomorphometric analyses and shear strength test. The microstructure analysis of the samples was performed by scanning electron microscope (SEM), energy dispersive spectrometry (EDS) and Raman spectroscopy; the bone neoformation was evaluated by light microscopy (MO) and SEM comparing only sinterized implants with those submitted to biomimetic treatment. The EDS indicated that the implant surface after biomimetic treatment contained mainly calcium (Ca) and phosphorous (P) in addition to the presence of titanium. The Raman spectroscopy of the titanium implant, after biomimetic treatment, indicated the formation of a hydroxyapatite layer due to the characteristic peak and of great magnitude at 960cm-1. The MO and SEM images showed bone neoformation on the interface bone-implant and inside the porous, including the most internal ones. It was observed that the mean percentage of bone neoformation in the treated implants for the three sacrifice periods were higher than the untreated implants, statistically significant for the 15-day period. The mechanical test showed that the coated implants... (Complete abstract, click electronic access below)
389

Comparação das avaliações histológica, clínica e por meio de exames de imagens da qualidade óssea da região maxilomandibular para a instalação de implantes dentários / Comparison of histological, clinical and imaging evaluations of the bone quality of different maxillomandibular regions for placement of dental implants

Oliveira, Marina Reis [UNESP] 14 March 2017 (has links)
Submitted by Marina Reis Oliveira (marinareis89@hotmail.com) on 2017-03-27T11:56:30Z No. of bitstreams: 1 Tese Doutorado - Marina Reis Oliveira.pdf: 3425386 bytes, checksum: ec09aa76b0be923cb1b87f76fc5aee71 (MD5) / Approved for entry into archive by Luiz Galeffi (luizgaleffi@gmail.com) on 2017-03-29T18:49:21Z (GMT) No. of bitstreams: 1 oliveira_mr_dr_arafo.pdf: 3425386 bytes, checksum: ec09aa76b0be923cb1b87f76fc5aee71 (MD5) / Made available in DSpace on 2017-03-29T18:49:21Z (GMT). No. of bitstreams: 1 oliveira_mr_dr_arafo.pdf: 3425386 bytes, checksum: ec09aa76b0be923cb1b87f76fc5aee71 (MD5) Previous issue date: 2017-03-14 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O presente trabalho teve como objetivo avaliar a qualidade óssea das diferentes regiões alveolares da maxila e da mandíbula por meio da classificação óssea proposta por Leckholm e Zarb (1985) (L & Z), radiografias panorâmicas e periapicais, quociente de estabilidade do implante (ISQ), torque de inserção (TI), microtomografia computadorizada (micro-CT) e histomorfometria. Como objetivo secundário, foi avaliada a correlação entre os diversos métodos citados acima. Foram avaliadas 60 áreas edêntulas, sendo 15 áreas de cada quadrante da maxila e da mandíbula. A qualidade óssea tipo III foi a mais frequente na maxila posterior (73,33%) e anterior (73,33%), já a tipo II foi mais frequente na mandíbula posterior (53,33%) e anterior (60,00%). Foi observada uma diferença estatisticamente significante na densidade óssea óptica avaliada por meio de radiografias periapicais na região posterior da maxila (2,38±1,06) e posterior da mandíbula (3,84±0,68), em relação às demais regiões alveolares avaliadas (p≤0,015). Nas radiografias panorâmicas não foram observadas diferenças entre a densidade óptica das regiões alveolares (p=0,6322). A estabilidade inicial dos implantes instalados na região posterior da maxila foi estatisticamente diferente dos instalados na região posterior da mandíbula, tanto na avaliação por meio do TI como por meio do ISQ (p<0,05). Também foi possível detectar diferenças na qualidade óssea das regiões alveolares da maxila e da mandíbula por meio de vários parâmetros da micro-CT (BV, p≤0,002; BV/BT, p≤0,044; BS, p<0,027; BS/BV, p<0,05; BS/TV, p<0,05; Tb.N, p<0,01 e Tb.Sp, p<0,05). Por meio da histometria foi verificada diferença estatística na quantidade de tecido ósseo da região posterior da maxila em relação a região anterior e posterior da mandíbula (p≤0,043). Entretanto, não houve diferenças na contagem de osteócitos entre as regiões alveolares (p=0,2946). Quanto à análise de correlação, a densidade óssea óptica avaliada por meio das radiografias periapicais correlacionou-se com o TI, com o ISQ e com vários parâmetros da micro-CT (BV, BV/BT, Tb.Th, Tb.N, BS/BV, Tb.Pf e ISM) (rho≤0,471; p≤0,028). Entretanto, a radiografia panorâmica apresentou apenas correlação com a BS e a BS/TV (rho≤0,290; p≤0,031). O TI apresentou correlação com o ISQ, histometria e vários parâmetros da micro-CT (BV, BS/TV, Tb.Th, Tb.N, BS/BV, Tb.Pf, Tb.Sp, BV/BT) (rho≤0,550; p≤0,022). Em contrapartida, o ISQ não apresentou correlação com nenhum parâmetro da micro-CT. A classificação de L & Z mostrou correlação com a densidade óptica avaliada por meio das radiografias periapicais, histometria, contagem de osteócitos, TI e vários parâmetros da micro-CT (BS/BV, Tb.Sp, Tb.Pf, BV, BS/TV, Tb.Th, Tb.N) (rho≤0,344; p≤0,042). Esses resultados sugerem que a classificação óssea de L & Z e o TI podem ser considerados métodos confiáveis na avaliação da qualidade óssea. As radiografias periapicais são um método aceitável na avaliação da qualidade óssea. A radiografia panorâmica, por sua vez, não se mostrou um método confiável para a avaliação da qualidade óssea. / This study aimed to evaluate the bone quality of the different alveolar regions of the maxilla and mandible through of the classification proposed by Leckholm e Zarb (1985) (L & Z), panoramic and periapical radiographs, implant stability quotient (ISQ), insertion torque (IT), microcomputed tomography (micro-CT) and histomorphometric analysis. The secondary objective was to evaluate the correlation between the several methods mentioned above. Sixty edentulous areas were evaluated, being 15 areas from each quadrant of the maxilla and mandible. The bone quality III was the most frequent in the posterior (73.33%) and anterior maxilla (73.33%) and quality II was the most frequent in the posterior (53.33%) and anterior (60.00%) mandible. A significant statistical difference was observed in the optical bone density evaluated through periapical radiographs of the posterior maxilla (2.38 ± 1.06) and posterior mandible (3.84 ± 0.68), in relation to the other alveolar regions (p≤0.015). With the panoramic radiograph no differences were observed between the optical density of the alveolar regions (p= 0.6322). The primary stability of the implants in the posterior maxilla was different from the posterior mandible, both in the evaluation through the TI and ISQ (p<0.05). It was possible to detect differences in the bone quality of the alveolar regions using several micro-CT parameters (BV, p≤0.002; BV/BT, p≤0.044; BS/TV, p <0.05; Tb.N, p<0.01 and Tb.Sp, p <0.05). With the histometry it was possible to detect difference in the amount of bone of the posterior maxilla in relation to the anterior and posterior mandible (p≤0,043). However, there were no differences in osteocyte counts between the alveolar regions (p=0.2946). Concerning the correlation analysis, the optical bone density evaluated by the periapical radiographs correlated with the TI, ISQ and various parameters of the micro-CT (BV, BV/BT, Tb.Th, Tb.N, BS/BV, Tb.Pf and ISM) (rho≤0.471, p≤0.028). In contrast, the ISQ did not correlate with any of the micro-CT parameters. The L & Z classification showed correlation with the optical density evaluated by periapical radiographs, histometry, osteocyte count, TI and several microCT parameters (BS/BV, Tb.Sp, Tb.Pf, BV, BS/TV, Tb.Th, Tb.N) (rho≤0.344; p≤0.042). Those results suggest that the L & Z bone classification and TI can be considered reliable methods for evaluating bone quality. Periapical radiographs are an acceptable method for assessing bone quality. The panoramic radiograph, on the other hand, is not a reliable method for evaluating bone quality. / FAPESP: 2014/25253-1
390

Resposta pulpar de dentes de cães submetidos ao tratamento clareador /

Miranda, Carolina Baptista. January 2005 (has links)
Orientador: Clóvis Pagani / Coorientadora: Márcia Carneiro Valera / Texto completo disponível em: http://www.dominiopublico.gov.br/pesquisa/DetalheObraForm.do?select_action=&co_obra=99401 / Doutor

Page generated in 0.0402 seconds