• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2304
  • 155
  • 150
  • 150
  • 148
  • 109
  • 35
  • 35
  • 24
  • 17
  • 17
  • 12
  • 7
  • 5
  • 2
  • Tagged with
  • 2362
  • 1247
  • 1039
  • 886
  • 534
  • 523
  • 493
  • 433
  • 425
  • 347
  • 234
  • 192
  • 180
  • 166
  • 163
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
451

A percepção do cirurgião dentista quanto ao tipo de infraestrutura utilizado em próteses unitárias implantossuportadas

Melo, Eduardo Vilain de January 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2012-10-26T09:41:12Z (GMT). No. of bitstreams: 1 304953.pdf: 1294497 bytes, checksum: d1f4940f51ab0956e463d12142ccb9a6 (MD5) / Objetivos: Avaliar a percepção de cirurgiões-dentistas pós-graduados nas áreas de periodontia, implantodontia, dentística restauradora e prótese dentária, em diagnosticar qual tipo prótese (cerâmica ou metalocerâmica) foi utilizada na reabilitação protética, em implantes unitários na região dos incisivos laterais superiores. Materiais e Métodos: Cinco implantes unitários na região do incisivo lateral superior foram restaurados, com dois tipos de próteses parafusadas diretamente sobre o implante (próteses metalocerâmica e cerâmica). Foram realizadas fotografias de ambas as próteses em posição, totalizando 10 imagens, que foram apresentadas a 40 avaliadores. Estes foram divididos em 5 grupos, de acordo com a área de especialidade (Pós-graduados em Dentística/Prótese Dental ou Periodontia/Implantodontia) e tempo de formado em odontologia (maior ou menor que 10 anos). Os avaliadores tinham de responder se a prótese era: cerâmica, metalocerâmica ou que não sabiam dizer. Resultados: Os Grupos 1, 3, 4 e 5, falharam em responder corretamente (P > 0.05), qual tipo de prótese foi apresentada, se mantendo, de maneira geral, dentro de um padrão aleatório de acerto. No Grupo 2 (Pós graduados em Periodontia/Implantodontia), em relação as próteses metalocerâmicas, o índice de acerto foi de 35,6% (P = 0.009), abaixo do índice aleatório, apresentando um resultado falso positivo. Conclusão: Os avaliadores foram incapazes de diferenciar de maneira significativa, qual tipo de prótese era cerâmica ou metalocerâmica nos 10 casos apresentados, comprovando assim, a hipótese de que as próteses metalocerâmicas ou cerâmicas são indistinguíveis ao olho humano, nas situações propostas pela metodologia deste estudo. / Objective: To evaluate the perception of postgraduates dentists in the areas of periodontics, implant dentistry, restorative dentistry and prosthodontics, to diagnose what type prosthesis, metal-free or porcelain-fused-to-metal (PFM), was used in the prosthetic rehabilitation of single-tooth implants in the lateral maxillary incisor region. Materials and Methods: Five single-tooth implants in the maxillary lateral incisor region were restored with two types of prostheses (PFM prosthesis and metal-free) directly screwed over the implant. Photographs were taken of both prostheses in position over the same the implant, totaling 10 images, which were presented to 20 evaluators. The evaluators were divided into five groups according to their area of expertise (Postgraduates in Periodontics/Implantology or Restorative Dentistry/Prosthodontics) and time of graduation in dentistry (over or under 10 years). The evaluators had to answer whether the prosthesis was: metal-free, PFM or could not tell. Results: Groups 1, 3, 4 and 5 failed to respond correctly (P > 0.05), which type of prosthesis was presented to him, remaining in a random pattern of accuracy. In Group 2 (Postgraduates in Periodontics/Implantology), in relation to metal-free prostheses, the accuracy rate was 35.6% (P = 0.009), below the random index, showing a false-positive result. Conclusion: The evaluators were unable to significantly differentiate which type of prosthesis, being it free of metal or PFM, was used in the 10 presented cases, thus, proving the hypothesis that PFM or metal-free prostheses are indistinguishable to the human eye in the situation proposed by the methodology of this study.
452

Avaliação da formação óssea em implantes usinados de titanio estimulados eletricamente

Cordero, Ernesto Barquero 04 March 2013 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia. / Made available in DSpace on 2013-03-04T18:56:18Z (GMT). No. of bitstreams: 1 308816.pdf: 15327211 bytes, checksum: f5a29b5fa8f89db479c5e875a0ad9e25 (MD5) / O estimulo eletrico tem sido utilizado para a cicatrizacao nos tratamentos de fratura refrataria ou deficiencia na consolidacao. Sao poucos os estudos que relatam este tipo de estimulo na odontologia, especialmente na implantodontia. No presente estudo foram usinados implantes dentarios sem tratamento de superficie, assim como foi testado e confeccionado um dispositivo eletrico acoplado a eles. O objetivo do presente estudo foi avaliar o contato osso/implante e a area de formacao ossea em implantes associados a um dispositivo que emite um estimulo eletrico continuo com duas diferentes amplitudes, colocados em um modelo animal. Material e metodos: Foram colocados 90 implantes de titanio com superficie usinada em 6 caes da raca Beagle. Os animais foram divididos aleatoriamente em dois tempos de avaliacao, de 7 e 15 dias (3 animais por tempo) e em cada uma de suas patas foi instalado o mesmo grupo de amostras. Para o grupo A: 10 ÊA, B: 20 ÊA e C: controle. Resultados: Obtidos por meio da analise de variancia (ANOVA) e teste de Tukey para as comparacoes multiplas e com nivel de significancia de 5% (p < 0,05). Para o grupo de 7 dias nao ocorreram diferencas estatisticas; para o grupo de 15 dias o estudo apresentou diferencas estatisticas significantes entre os grupos, seja quando avaliado o contato osso/implante, seja pela area periferica ao implante (p < 0,01). Excecao feita quando comparadas as areas do grupo A (10 ÊA) e do grupo C (controle), com relacao as quais nao houve diferenca estatistica (p > 0,05). Conclusao: O estimulo eletrico associado aos implantes de titanio possui a capacidade de gerar maior contato osso/implante, bem como maior formacao ossea, quando comparado com implantes que não utilizam este estimulo
453

Análise de afrouxamento do parafuso de intermediários protéticos de titânio e zircônia em implantes hexágonos externos

Oliveira, Rafaella Monteiro Cid January 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2013-06-25T22:44:47Z (GMT). No. of bitstreams: 0
454

Análise da frequência de ressonância de implantes zigomáticos submetidos a função imediata/precoce

Magalhães Junior, Edival Barreto de January 2005 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2013-07-15T22:54:23Z (GMT). No. of bitstreams: 1 228112.pdf: 1275787 bytes, checksum: 79e019045ca71eb1c0e747afd40fbfdb (MD5) / O objetivo do estudo foi analisar a evolução da freqüência de ressonância de implantes zigomáticos submetidos a função imediata/precoce (teste) num período de 06 meses, em pacientes com maxila severamente absorvida e, compará-los com a estabilidade dos implantes zigomáticos que tiveram função tardia (controle), e ainda, compará-los com implantes convencionais instalados na região anterior da maxila. Foram avaliados 09 pacientes e mensurados um total de 50 implantes, sendo 18 zigomáticos e 32 convencionais. Os registros foram realizados no momento da instalação do implante (0 dia), em 90 dias e 180 dias para o grupo teste, e, 0 e 180 dias para o controle. No grupo teste, os valores médios da análise da freqüência de ressonância dos implantes zigomáticos na instalação foi de 61,3 ± 18,91 ISQ (quoeficiente de estabilidade do implante), 90 dias após foi de 62,56 ± 9,38 ISQ e em 180 dias, a média foi de 69,44 ± 6,12 ISQ. Não houve diferença estatística comparando 0 e 90, e 0 e 180, porém houve diferença estatisticamente significante para 90 a 180 dias. Foram perdidos 01 implante zigomático e 3 convencionais. No grupo controle, a média ISQ foi de 59,88 no dia da instalação e 61,25 180 dias após. Os valores de freqüência de ressonância dos implantes zigomáticos submetidos a carga imediata/precoce apresentaram uma elevação contínua durante todo o período estudado, e registraram valores médios superiores aos tardios, tanto na instalação quanto 180 dias após. Na comparação entre os tipos de implantes localizados na região posterior (zigomático) e anterior (convencional) da maxila, não houve diferença estatisticamente significante. O estudo apresentou uma taxa de sobrevivência para os implantes zigomáticos teste e controle após 180 dias, de 90% e 100%, respectivamente. The purpose of this clinical study was to evaluate during 06 months, in patients with severe resorbed maxilla, the stability of immediate/early loading zygomatic implants (test) by means of resonance frequence analysis (RFA), compare the stability against delayed loaded zygomatic implants (control) and conventional implants in the anterior maxilla. RFA was used for direct measurement of implant stability of 18 zygomatic and 32 conventional implants in 09 patients. Each implant was tested for primary stability at the time of implant placement, after 90 days and 180 days following surgery. Control group was only assessed at placemet and 180 days. In the test group, the mean values of RFA was 61,3 ± 18,91, 62,56 ± 9,38 and 69,2 ± 6,12 implant stability quotient(ISQ), respectively at the placement, at 90 days, and 180 days. there was no statistically significant difference when was compared 0 to 90 , and 0 to 180, however, from 90 to 180 there was difference. One zygomatic implant and 03 conventional implants failed. In the control group, the mean ISQ values were 59,88 at placement and 61, 25 at 180 days. Resonance frequency analysis method showed a continuous increase of zygomatic immediate/early loading ISQ values during the study and the test group mean ISQ values were higher than the control group both at placement and 180 days after. When comparing implant position (length), i.e., zygomatic against conventional implants, there was no difference in the resonance frequency analysis. The clinical zygomatic implant survival rate during this study for the test and control group was 90% and 100%.
455

Avaliação do torque de remoção na interface osso/implante promovida por estimulação elétrica em implantes dentários

Barquero Cordero, Ernesto January 2009 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2009 / Made available in DSpace on 2013-07-16T03:46:36Z (GMT). No. of bitstreams: 1 317105.pdf: 2288579 bytes, checksum: 89f4ec506698ce33280fb35bd48b7266 (MD5) / O objetivo desta pesquisa foi avaliar a influência de estímulos elétricos no torque de remoção de implantes dentários. Para tal foram inseridos 18 implantes nas tíbias de 6 cães da raça Beagle, esses implantes foram divididos em 3 grupos: A (Implante dentário com dispositivo elétrico de 10 µA), B (Implante dentário com dispositivo elétrico de 20 µA) e C (Implante dentário sem dispositivo elétrico - controle). Os torques de inserção foram mensurados no final da instalação do implante e os torques de remoção foram mensurados com 7 e 15 dias pós-cirúrgicos. Os valores obtidos foram analisados estatísticamente por meio do teste Anova One-Way e teste de correlação de Spearman. Não foram encontradas diferenças significativas entre os tempos e os grupos avaliados. Pode-se concluir que, ao teste biomecânico, o estímulo elétrico não influencia no torque de remoção do implante.<br> / Abstract : The objective of this study was to evaluate the influence of electrical stimulation on the removal torque of implants. To that 18 implants were inserted in the tibia of 6 Beagle dogs, these implants were divided into 3 groups: A (Dental implant fixture with 10 ìA), B (Dental implant fixture with 20 ìA) and C (Implant without dental fixture - control). The insertion torques were measured at the end of the installation of the implant and removal torques were measured at 7 and 15 days after surgery. The data were analyzed statistically by means of the One-Way ANOVA test and Spearman correlation. There were no significant differences between times and groups. Can be concluded that the biomechanical test, the electrical stimulation does not influence the torque of the implant.
456

Análise da interface adesiva de materiais obturadores à dentina do canal radicular

Tedesco, Maybell January 2016 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2016. / Made available in DSpace on 2016-09-20T05:06:21Z (GMT). No. of bitstreams: 0 Previous issue date: 2016Bitstream added on 2017-04-04T04:10:03Z : No. of bitstreams: 1 340360.pdf: 2069422 bytes, checksum: 236ac1415e494885dedbc502f10fe93e (MD5) / A adesão em endodontia é um processo complexo que depende de fatores químicos e mecânicos relativos à interação dos cimentos endodônticos à dentina das paredes do canal radicular. O material obturador firmemente aderido à dentina contribui para o preenchimento tridimensional do canal e longevidade da obturação. Estudos comparativos com diferentes materiais e métodos observacionais são essenciais para a avaliação e desenvolvimento de novos produtos. Sendo assim, os objetivos do presente estudo, ex vivo e in vitro, foram: 1º- Comparar a acurácia da microscopia eletrônica de varredura (MEV) com a microscopia de varredura a laser confocal (Confocal) na análise da interface adesiva e penetração intratubular de dois cimentos endodônticos, AH Plus e Endofill; 2º- Avaliar a existência de correlação entre resistência de união à dentina e penetração intratubular de três cimentos endodônticos: Endofill, AH Plus e MTA Fillapex por meio dos testes de push-out e análise com Confocal; 3º- Avaliar a influência da adição do corante fluorescente, rodamina B, nas propriedades físicas-químicas de dois cimentos endodônticos, AH Plus e MTA Fillapex. Embora os objetivos sejam correlacionados, os experimentos tiveram metodologias e amostras distintas, o que fez com que os resultados do presente estudo fossem apresentados em três artigos. Cada artigo foi detalhado de acordo com os objetivos propostos, recebeu análise estatística dos resultados obtidos e discussão embasada na literatura vigente.<br> / Abstract : The adhesion in endodontics is a complex process witch depends on physical and mechanical factors related to the interaction between endodontic sealer to dentine canal walls. The filling material firmly attached to dentin contribute to the tridimensional filling and longevity of treatment. Comparative studies with different materials and observational methods are essential to evaluate and development of new products. Therefore, the objectives of the present study, ex vivo e in vitro were: 1º- Compare the acuracy of the scanning electronic microscopy evaluation (SEM) with confocal laser scanning microscopy (Confocal) on the adhesive interface and intratubular penetration evaluation of two endodontic sealers, AH Plus and Endofill; 2º- Evaluate the existence of a correlation between bond strength (BS) and intratubular penetration of three endodontic sealers: Endofill, AH Plus and MTA Fillapex, through push-out and Confocal evaluation; 3º- Evaluate the influence of the addition of a fluorescent dye, rhodamine B, in the physical-chemical properties of two endodontic sealers, AH Plus e MTA Fillapex. Although the objectives are correlated, the experiments had different methodology and samples; that makes the results of the present study be presented in three individual articles. Each article was detailed according to the goals proposed and have received statistical analysis of the data and discussion based on the current literature.
457

Resistência à fratura de diferentes materiais para retentores intrarradiculares

Teixeira, Karla Nunes January 2016 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2016. / Made available in DSpace on 2016-10-18T03:08:30Z (GMT). No. of bitstreams: 1 342143.pdf: 3205659 bytes, checksum: 638cd711df5fc22fea49e0fe61264b4a (MD5) Previous issue date: 2016 / O objetivo deste trabalho in vitro foi avaliar a resistência à fraturae o tipo de falha de novos materiais utilizados como retentoresintrarradiculares cimentados em condutos de raízes de dentes humanos.Foram selecionados 48 pré-molares inferiores, hígidos, com apenas umconduto radicular. Os dentes tiveram suas coroas seccionadas e oscondutos radiculares endodonticamente tratados e, na sequência,randomizados em 4 grupos (n = 12), conforme o material de composiçãodos pinos/núcleos: poliéter-éter-cetona (PEEK), resina composta comcarga nanocerâmica (RNC), núcleo metálico fundido com liga de níquelcromo(NMF) e pino de fibra de vidro reembasado com resina composta(PFC). As raízes foram incluídas em resina acrílica, os pinos/núcleoscimentados (todos com o mesmo cimento resinoso autoadesivo dual) e,em seguida, os espécimes foram armazenados em água destilada a 37°Cpor 60 dias. Na sequência, foram submetidos ao teste de resistência àfratura por compressão, a 0,5 mm/min sob um ângulo de 45° em relaçãoao eixo longitudinal do dente, em máquina de ensaio universal, até afratura. As fraturas foram classificadas como reparáveis e irreparáveis.Os valores de resistência à fratura assim obtidos foram submetidos aoteste estatístico ANOVA, com grau de confiança de 95%, para detectardiferenças estatísticas entre os grupos (p < 0,001). De acordo com o testePost-hoc Tukey, os resultados de resistência à fratura do Grupo NMF(939,61 N) foram estatisticamente superiores aos dos demais grupos (p <0,05), enquanto não houve diferença estatística entre os Grupos PFC(449,63 N), PEEK (396,07 N) e RNC (511,59 N) (p > 0,05). Falhasirreparáveis aconteceram em maior número no Grupo NMF (10).Também no Grupo RNC ocorreram duas falhas irreparáveis. Já nosGrupos PFC e PEEK todas as falhas foram consideradas reparáveis.Apesar de mostrar maior resistência à fratura, o Grupo NMF teve falhasirreparáveis, desfavoráveis ao retratamento. Um material de reconstruçãoradicular com alta resistência à fratura não garante que o complexoraiz/retentor intrarradicular fique protegido de uma falha catastróficacomo a fratura radicular.<br> / Abstract : The aim of this in vitro study was to evaluate the fracture strengthand the type of failure of new materials used as intracanal retainers,visible in conduits of human teeth roots. We selected 48 premolars,healthy, with only one root canal. The teeth were sectioned crowns andendodontically root canal treated and, randomized into 4 groups (n = 12)as the material composition of post/cores: polyether ether ketone (PEEK)composite resin with nanoceramic load (CRN), molten metallic core withnickel-chromium alloy (NMF) and glass fiber post with composite resin(GFP). The roots were embedded in acrylic resin, the post/core cemented(all with the same resin cement dual self adhesive) and then thespecimens were stored in distilled water at 37°C for 60 days. In thefollowing, they were subjected to compression fracture resistance test at0.5 mm/min at an angle of 45° relative to the longitudinal axis of thetooth in an universal testing machine until fracture. Fractures wereclassified as repairable and irreparable. The fracture resistance valuesthus obtained were submitted to ANOVA, with confidence level of 95%to detect statistical differences between the groups, which have beenproven (p < 0.001). According to the Post-hoc Tukey test, resistance tofracture results of the NMF Group (939.61 N) were statistically superiorto the other groups (p < 0.05), whereas there was no statistical differencebetween the PFC (449.63 N), PEEK (396.07 N), and RNC (511.59 N)Groups (p > 0.05). Irreparable failures occurred in greater numbers in theNMF Group (10). Also in the CRN Group there were two irreparablefailures. Already in the PFC and PEEK Groups all faults were consideredrepairable. Despite showing greater resistance to fracture, the NMFGroup has irreparable flaws, unfavorable to retreatment. A rootreconstruction material with high fracture resistance does not guaranteethat the complex root/post and core be protected from a catastrophicfailure as the root fracture.
458

Avaliação do padrão superficial e geométrico de parafusos para retenção de próteses implanto-suportadas

Souza, Dircilene Colares de January 2004 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2012-10-21T13:06:40Z (GMT). No. of bitstreams: 1 203834.pdf: 3543184 bytes, checksum: a6214c4ff6b59467b73214809fcbf768 (MD5) / O objetivo deste trabalho foi analisar através de microscopia eletrônica de varredura (MEV) o padrão de fabricação de parafusos para retenção de próteses implanto-suportadas. A presença de irregularidades superficiais e parâmetros geométricos foram registrados em 87 parafusos divididos em 6 grupos das marcas comerciais 3i Implant Innovations; Nobel Biocare; Conexão Sistema de Prótese; Neodent; INP e Grupo Experimental. Os dados coletados foram submetidos a tratamento estatístico. Os resultados revelaram que todos os grupos apresentavam diferença estatisticamente significante em pelo menos um dos parâmetros observados dentro da sua amostra. Concluiu-se que todos os grupos avaliados apresentaram irregularidades e diferenças geométricas nos parafusos.
459

Otimização da macrogeometria e avaliação da resistência à torção de parafusos de osso cortical bovino desproteinizado

Oliveira, Octavio Magnani Ramos de January 2004 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia. / Made available in DSpace on 2012-10-21T17:26:43Z (GMT). No. of bitstreams: 1 210534.pdf: 22010334 bytes, checksum: 24b2b72c9c77f55548defd7ad3653db6 (MD5) / O objetivo deste trabalho é propor uma macrogeometria alternativa bem como realizar a avaliação da resistência à torção de parafuso fabricado de osso cortical bovino desproteinizado, para futuro uso clínico, em substituição de enxertos ósseos. Estes parafusos tiveram como referência as dimensões (diâmetro e comprimento) dos implantes bucais do tipo Osseotite NT MicroMini de 3,25mm x 8,5mm da marca 3i. Foram confeccionados com as seguintes dimensões: área da cabeça de 4,0mm x 4,0mm; comprimento da cabeça de 5,0mm e de rosca cônica trapezoidal de 5,0mm, possuindo diâmetro de 3,0mm no maior e 2,0mm no menor. Foi analisado um lote de 12 parafusos cônicos quanto a resistência à torção com o uso de torquímetro, objetivando avaliar sua resistência à fratura. Os resultados do aplicativo deste material e desta geometria cônica, mostraram-se adequados e práticos, atingindo as expectativas iniciais dos pesquisadores quanto ao uso clínico do referido tipo de implante.
460

Avaliação incipiente da influência do plasma rico em plaquetas na proliferação de osteoblastos humanos

Ferreira, Cimara Fortes January 2004 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia. / Made available in DSpace on 2012-10-22T00:06:54Z (GMT). No. of bitstreams: 1 204203.pdf: 259703 bytes, checksum: b99946da0b60552661630267cbaa1f75 (MD5) / Este trabalho avalia a ação de diferentes concentrações de PRP aplicadas em cultura celular da linhagem de osteoblasto humanos hFOB1.19 (American Tissue Culture Collection). A metodologia envolveu o teste proliferativo do ensaio do brometo de 3-[4,4-dimetiltiazol-2-4l]-2,5-difeniltetrazolio (MTT). O plasma rico em plaquetas (PRP) obtido foi processado e diluído em meio de cultura a 50%, 25%, 12,5% e 6,125%. As concentrações de soro fetal bovino (SFB) foram de 0% e 10% em meio de cultura. A proliferação foi lida por densidade óptica após um intervalo de tempo de 96 h em leitor de Elisa. Os resultados obtidos neste trabalho indicam que 50% de PRP adicionado ao meio de cultura para osteoblastos humanos da linhagem hFOB1.19, induziu a melhor resposta proliferativa. As concentrações de 12,5% e 6,125% de PRP não mostraram diferença estatisticamente significativa. Verificou-se que a proliferação celular obtida pelo PRP a 50% foi mais significativa, em cultura com e sem SFB, comparada com as outras diluições realizadas. Conclui-se que o PRP promove proliferação de osteoblastos e indica que não é necessário soro para indução da proliferação de osteoblastos mediada pelo PRP, sugerindo o seu uso clinicamente para otimizar procedimentos de enxertia óssea na implantodontia.

Page generated in 0.0681 seconds