• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2304
  • 155
  • 150
  • 150
  • 148
  • 109
  • 35
  • 35
  • 24
  • 17
  • 17
  • 12
  • 7
  • 5
  • 2
  • Tagged with
  • 2362
  • 1247
  • 1039
  • 886
  • 534
  • 523
  • 493
  • 433
  • 425
  • 347
  • 234
  • 192
  • 180
  • 166
  • 163
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
791

Avaliação da resistência à fratura de dentes tratados endodonticamente com pinos pré-fabricados e resinas compostas variando a quantidade de remanescente dentário coronal / Fracture strength assessment of teeth endodontically treated, restored with prefabricated posts and compound resins, and varying amount of remaining coronal dental structure

Melo, Murilo Pereira de 17 February 2003 (has links)
O objetivo desta pesquisa foi avaliar a influência do remanescente dentário coronal de dentes tratados endodonticamente, restaurados com pinos pré-fabricados e duas resinas como núcleos de preenchimento, uma de presa dual (Enforce Core) e outra fotopolimerizável (Z-250). Foram utilizados 40 caninos superiores humanos extraídos, divididos em quatro grupos de 10 espécimes: Grupo l – com remanescente dentário coronal de 3mm e restaurados com Enforce Core; Grupo ll – com remanescente dentário coronal de 3mm e restaurado com Z-250; Grupo III – sem remanescente dentário coronal e restaurado com Enforce Core; Grupo IV – sem remanescente dentário coronal e restaurado com Z-250. Após restaurados, os dentes foram levados a uma Máquina de Ensaio Universal e submetidos a uma força de compressão à 45º até que ocorresse fratura da restauração. A análise dos resultados (ANOVA, p>0,05) mostrou não haver diferença estatisticamente significativa entre os dentes com e sem remanescente dentário coronal. Com relação ao material utilizado para o preenchimento coronário, constatou-se diferença significativa, sendo que os valores mais elevados de resistência à fratura foram encontrados no grupo restaurado com a resina fotopolimerizável. / The aim of this study was to evaluate the remaining coronal dental structure influence of endodontically treated teeth, restored with prefabricated posts and two different types of resin filling cores, a dual cure resin (Enforce Core) and a photopolymerizing resin (Z-250). 40 extracted upper canine human teeth were used, divided into four groups of 10 specimens each: Group I – with coronal dental structure of 3mm restored with Enforce Core; Group II – with coronal dental structure of 3mm restored with Z-250; Group III – without any remaining coronal dental structure restored with Enforce Core; Group IV – without any remaining coronal dental structure restored with Z-250. After the complete restoration, the teeth were taken to a universal test machine, and then submitted to compression forces at 45º, until reaching the fracture of the restoration. The analysis of the results (ANOVA, p>0,05) showed no statistically significant difference between the teeth with or without coronal dental structure. In relation to the material used for the coronal filling, there has been a statistically significant difference. Higher fracture strength values were found in the group restored with photopolymerizing resin.
792

Estudo de interfases eletroquímicas envolvendo materiais metálicos de uso odontológico / Electrochemistry interphases study involving odontologic metallic materials.

Vieira, Jocicler Claudio 25 April 2006 (has links)
Interfases \"metal - solução eletrolítica de interesse odontológico\" foram estudadas a 36,5 graus Celsius por técnicas eletroquímicas estacionárias. Duas ligas, Au-Pt-Pd e Ni-Cr-Mo-Ti, foram comparadas e, neste caso, empregadas a impedância eletroquímica, a microscopia eletrônica de varredura e a espectroscopia de dispersão de energia. Os estudos também incluíram o Ti-cp e a amálgama Ag-Cu-Sn-Zn. Verificou-se o efeito da adição de NaF, de ácido cítrico (H3Cit) e de albumina de soro bovino (BSA) ao meio de NaCl. A liga Ni-Cr-Mo-Ti, desenvolvida para substituir a liga Au-Pt-Pd, apresenta comportamento bem diverso da segunda, caracterizado por uma superfície irreprodutível, potencial de corrosão 200 mV a 500 mV mais negativo, dependendo do meio, e faixa passiva inexistente ou de pequena amplitude de potencial. O Ti-cp está passivado em todo o intervalo de potencial estudado (2 V/ECS) em meios de NaCl e NaCl+H3Cit; em NaCl+NaF, a faixa passiva é bem mais restrita, e a BSA a eleva de 100 mV. O H3Cit destrói o filme passivo sobre as ligas Ni-Cr-Mo-Ti e amálgama. A BSA exerce efeitos distintos dependendo da natureza do material metálico e do meio, sugerindo ora adsorção física, ora ação complexante. São discutidos diferentes tipos de embutimento para as amostras metálicas, como teflon, resinas epóxi e epóxi-vinil-éster (EVER). O embutimento com EVER é o mais recomendável para materiais de uso odontológico. / Different metal electrolytic interphases with relevance for dental prosthesis and implants were studied at 36,5 degrees Celsius by stationary electrochemical techniques. Two alloys, Au-Pt-Pd and Ni-Cr-Mo-Ti, were compared and in this case, EIS, SEM and EDS were also employed as techniques. The studies also included Ti-cp and Ag-Cu-Sn-Zn amalgam. It was studied the effect of adding NaF, citric acid (H3Cit) and bovine serum albumin (BSA) to NaCl medium. Ni-Cr-Mo-Ti alloy, developed to substitute Au-Pt-Pd alloy, presents a distinct behaviour from the last mentioned alloy, characterized by an irreproducible surface, corrosion potential situated at 200 mV to 500 mV more negative value, depending of the medium, and narrow or absence of passive range. Ti-cp is passive in all the potential range studied (2 V/SCE) in NaCl and NaCl+H3Cit media; in NaCl+NaF the passive range is narrower and it increases 100 mV in the presence of BSA. H3Cit breaks down the passive film deposited on the Ni-Cr-Mo-Ti and amalgam alloy surfaces. BSA exhibits distinct effects depending upon both the nature of the alloy and the media suggesting either physical adsorption either complex formation. Different kinds of polymers for fitting the metallic samples are discussed, such as teflon, epoxy resin and epoxy vinyl ester resin (EVER). The results suggest that the EVER polymer is the most recommendable for fitting dental materials.
793

Efeitos dos protocolos de irrigação durante o preparo do espaço protético sobre a adesão de pino de fibra na dentina radicular /

Ramos, Anna Thereza Peroba Rezende. January 2019 (has links)
Orientador: Milton Carlos Kuga / Resumo: Objetivo: avaliar a influência do protocolo de irrigação: sem irrigação (WI), com irrigação alternada (AI) ou com a irrigação contínua (CI), em diferentes situações que influência diretamente na qualidade de adesão do pino de fibra de vidro ao substrato dentinário, para isso analisamos presença de resíduos, quantidade de túbulos dentinários abertos; resistência de união do sistema de cimentação na dentina; padrão de fratura da adesão e penetrabilidade dentinária. Material e métodos: raízes de incisivos bovinos foram obturadas, submetidas ao preparo para pino de fibra e distribuídas em grupos, de acordo com o protocolo de irrigação: (WI); (AI) e (CI), e o cimento utilizado (Allcem Core RelyX Ultimate). Após a conclusão do preparo, as raízes foram subdivididos em grupos (n=10), onde foram avaliadas em MEV para avaliar a presença de resíduos, em MEV para incidência de túbulos dentinários abertos na superfície dentinária, Microscopia Confocal a laser para avaliar a penetrabilidade, Estereomicroscopio para avaliar o padrão de fratura. Pinos de fibra foram cimentados com sistema de cimentação (RelyX Ultimate) nos demais espécimes (n=10) e submetidos ao teste de push-out e avaliação do padrão de fratura. Resultados: Em todas as avaliações os grupos que tiveram irrigação contínua no preparo do pino apresentaram valores significativamente melhores em relação ao que estava sendo analisado em especifico (P > 0,05). Os terços cervical e médio também apresentaram melhores resultado compar... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Objective: The aim of this study was to assess the influence of the irrigation protocol: without irrigation (WI), alternate irrigation (AI) or continuous irrigation (CI), in different situations that directly influence the adhesion quality of the fiber post to the dentin substrate, for this we analyzed the residues presence, the number of open dentinal tubules; bonding strength of the cementation system in dentin; adhesion failure pattern and dentin penetrability. Material and methods: roots of bovine were obturated, submitted to preparation for fiber post and distributed in groups, according to the irrigation protocol: (WI); (AI) and (CI), and the cement used (Allcem Core RelyX Ultimate). After the preparation was completed, the roots were subdivided into groups (n = 10), where they were evaluated in SEM to evaluate the residues, in SEM for incidence of open dentinal tubules on the dentin surface, Confocal laser microscopy to evaluate the penetrability, stereomicroscope to evaluate the failure pattern. Posts were cemented with cementation system (RelyX Ultimate) in the other specimens (n = 10) and submitted to the push-out test and evaluation of the failure pattern. Results: In all evaluations, the groups that had continuous irrigation in the preparation of the post showed significantly better values than the one being analyzed in specific (P> 0.05). The cervical and middle thirds also presented better results compared to the apical thirds. Conclusion: WI caused a greater p... (Complete abstract click electronic access below) / Doutor
794

Avaliação da resistência a tração de diferentes enxertos em calvária de ratos / Evaluation of the tensile strength of different grafts in rat calvaria

Sanada, Jefferson Tomio 15 December 2010 (has links)
A perda do osso alveolar como resultado de doença periodontal ou secundariamente à cirurgia são fontes de inúmeras complicações para os cirurgiões dentistas, e a solução para tal problema se baseiam em procedimentos regenerativos, que é realizada através de enxertos ósseos que estabelecem um arcabouço para a reparação tecidual, aumentando os tecidos ósseos nos defeitos resultantes de trauma ou cirurgias, preenchendo os alvéolos após extração para preservar a altura e espessura do rebordo alveolar e aumentando e/ou reconstruindo o rebordo alveolar. Este projeto tem como objetivo determinar a resistência à tração do osso neoformado com a utilização de diferentes biomateriais. Foram utilizados 60 animais divididos em 3 grupos. O grupo 1A (n=10): GenO; Grupo 1B (n=10): GenMix; Grupo1C (n=10): Bio-Oss; Grupo 2a (n=10): PerioGlas; Grupo 2b (n=10): Polímero de mamona e Grupo 3 (n=10): coágulo. Após 3 meses de nascimento os animais foram submetidos a anestesia intraperitonial e confecção de defeito não critico (3mm de diâmetro) na calvária dos animais, que foram preenchidos com os biomateriais correspondentes a cada grupo. Após 6 meses da cirurgia foi realizada a morte dos animais, os espécimes foram coletados e submetidos ao teste em uma máquina de teste universal. Observa-se que o grupo que obteve maior média de resistência à tração foi o grupo de polímero de mamona (10,932±4,529MPa). Consequentemente, obteve-se uma comparação descrescente na seguinte ordem: Coágulo (9,563±3,74MPa), Bio-Oss (8,706±4,087MPa), GenMix (8,587±3,602MPa), GenOx (7,709±2,416MPa), PerioGlas (7,185±6,837MPa), não notando-se diferença estatisticamente significante entre os grupos. Nas microscopias eletrônicas de varredura na maioria dos grupos observou-se presença de fibras colágenas ao redor do tecido ósseo neoformado e dos remanescentes de enxerto. Conclui-se que o material foi indiferente para o resultado final da resistência à tração, demonstrando uma boa qualidade dos materiais utilizados, tanto quando comparamos os produtos quanto a sua origem (xenogênica, polimérica ou coágulo), ou a sua procedência de fabricação (nacional ou importado). / The loss of alveolar bone as a result of periodontal disease or secondary to surgery are numerous sources of complications for the dentists, and the solution to this problem are based on regenerative procedures, which is conducted through bone grafts that provide a scaffold for tissue repair by increasing the bone tissues in the defects resulting from trauma or surgery, filling the alveoli after extraction to preserve the height and thickness and increasing the alveolar ridge and/or reconstructing the alveolar ridge. This project aims to determine the tensile strength of newly formed bone with the use of different biomaterials. We used 60 animals divided into three groups. Group 1A (n = 10): GenOx; Group 1B (n = 10): GenMix; Group 1C (n = 10): Bio-Oss; Groups 2a (n = 10): PerioGlas; Group 2b (n = 10): castor bean polymer; Group 3 (n = 10): clot. After 3 months of birth the animals were anesthetized intraperitoneally and making non critical defect (3mm diameter) in the calvaria of the animals, which were filled with biomaterials for each group. After 6 months of surgery was performed the animals\' death, the specimens were collected and tested in a universal testing machine. It is observed that the group had a higher average tensile strength was the castor oil polymer group (10.932 ± 4.529 MPa). Consequently, we obtained a comparison descended in the following order: Clot (9.563 ± 3.74 MPa), Bio-Oss (8.706 ± 4.087 MPa), GenMix (8.587 ± 3.602 MPa), GenOx (7.709 ± 2.416 MPa), PerioGlas (7.185 ± 6.837 MPa), not noticing a significant difference between the groups. In scanning electron microscopies in most groups there was presence of collagen fibers around the newly formed bone and remaining graft. It is concluded that the material was irrelevant to the final result of the tensile strength, showing a good quality of materials used, both when comparing products as their source (xenogenic, polymeric or clot), or its origin of manufacture (national or imported).
795

Efeito da adição de um inibidor de metaloproteinase sobre a resistência à microtração e citotoxicidade de um sistema adesivo autocondicionante / The effect of a matrix metalloproteinase 2 (MMP-2) inhibitor on the microtensile bond strength and cytotoxicity of a selfetching primer

Henn, Sandrina 27 March 2009 (has links)
Submitted by Fabiano Malheiro (fabianomalheiro22@hotmail.com) on 2017-05-18T13:37:08Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Efeito da adição de um inibidor de metaloproteinase sobre a resistência à microtração.pdf: 514427 bytes, checksum: 8b763b182dceaa708a22970145fa8e0c (MD5) / Made available in DSpace on 2017-05-18T13:37:08Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Efeito da adição de um inibidor de metaloproteinase sobre a resistência à microtração.pdf: 514427 bytes, checksum: 8b763b182dceaa708a22970145fa8e0c (MD5) Previous issue date: 2009-03-27 / Sem bolsa / O objetivo do presente estudo foi avaliar a influência da incorporação de um inibidor de metaloproteinase 2, (MMP-2) metacrilato de zinco (MZ), na resistência de união (μTBS) e citotoxicidade de um sistema adesivo autocondicionante comercial, Clearfil SE Bond (CSE). O primer do sistema adesivo autocondicionante foi modificado com o acréscimo de 1% ou 5% em massa de MZ. Clearfil SE Bond sem MZ foi utilizado como controle. Para oensaio de resistência de união, vinte e oito terceiros molares humanos foram utilizados, formando quatro grupos (7 dentes por grupo): CSEcontrole, CSEZM1 e CSEZM5 foram armazenados em água destilada e CSECHX armazenado em digluconato de clorexidina 2%. Os dentes foram restaurados, seccionados para obtenção de palitos e armazenados em estufa a 37°C por 24h, 6 ou 12 meses. Após, os palitos foram submetidos a ensaio de microtração (μTBS ) em máquina de ensaios mecânicos. Para o ensaio de citotoxicidade, fibroblastos de ratos imortalizados (3T3/NIH) foram expostos aos três primers (CSE, CSEZM1 e CSEZM5) por 12h e 24h. Meio DMEM (Meio Essencial de Eagle Modificado por Dulbecco) foi utilizado como controle. As células foram plaqueadas em concentrações de 2 x 104 células por poço e distribuídas em duas placas de cultivo celular. Teste de viabilidade celular MTT (sal tetrazolium [3-(4,5-dimetiltiazol-2-yl)-2,5-difeniltetrazolium brometo] foi utilizado para avaliar função metabólica das células. A absorbância de cada poço foi medida em um espectrofotômetro a 570 nm. Os dados de μTBS foram analisados por Análise de Variância uma Via e teste complementar de Tukey ( =0.05). Grupo CSEcontrol demonstrou silimar μTBS após armazenamento. O grupo CSEZM5 revelou queda na μTBS após 6 meses de armazenamento quando comparados ao controle. Os valores de citotoxicidade foram submetidos ao teste não paramétrico Kruskal-Wallis e método Sudent-Newmans-Keuls). Houve redução na atividade mitocondrial para todos os primers testados quando comparados ao controle contendo apenas DMEM. No entanto, os grupos CSEZM1 e CSEZM5 apresentoaram efeito citotóxico inferior ao primer comercial. De acordo com as limitações do presente estudo é possível concluir que os possíveis mecanismos de inibição de metaloproteinase testados, acréscimo de metacrilato de zinco ou armazenagem em clorexidina pode afetar negativamente a resistência de união do Clearfil SE Bond. No entanto, a citotoxicidade do primer comercial foi diminuída com o acréscimo de Metacrilato de Zinco. / The aim of this study was to investigate the effect of zinc methacrylate (ZM) as a matrix metalloproteinase2 (MMP- 2) inhibitor on the microtensile bond strength (μTBS) and cytotoxicity of a self etching adhesive system (Clearfil SE Bond – CSE). For mechanical test, the self-etching primer was modified with 1 or 5 % (wt) of ZM, while adhesive system served as control (CSE). Twenty-eight human third molars were randomly assigned into four groups (n=7 teeth per group): CSE, CSEZM1 and CSEZM5 were stored in distilled water and CSECHX was stored in 2% chlorhexidine digluconate. After restorative procedures, teeth were sectioned to obtain beams, stored at 37o C for 24 hour, 6 and 12 months. After, μTBS was measured. For cytotoxicity test, mouse fibroblasts (3T3/NIH) were exposed to extracts of three different primers (CSE, CSEZM1 and CSEZM5) for 12 and 24h. Medium DMEM (Dulbecco’s Modified Eagle’s Medium) as used as control. The cell was plated (2 x 104/well) in two 96 round-bottomed tissue culture plates. The MTT (3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide) assay was used to asses cell metabolic function by mitocondrial dehydrogenase activity. The absorption at 570nm was determined spectrophotometrically. Data of μTBS were analyzed by One-Way Anova and Tukey test ( =0.05). Control group show similar μTBS after storage times. The CSEZM5 disclosed a decrease of bond strength after six moth storage and statistically lower μTBS means when compared with control group (p<0.05) Cytotoxicity was analyzed using Kruskal-Wallis test and Sudent-Newmans- Keuls method. There was a reduction in cell viability after exposure in all tested groups when compared to the Control. However, cytotoxicity of CSEZM1 and CSEZM5 were lower than CSE. The addition of zinc methacrylate on self-etching primer or storage in chlorhexidine may negatively affect μTBS of CSE. However, cytotoxicity of the commercial primer may decreased with ZM addition.
796

Avaliação do efeito antifúngico de fixadores de dentaduras modificados pelo acréscimo de derivados pirazolinicos / Antifungal effect evaluation fasteners dentures modified by the addition pirazolinicos derivatives

Oliveira, Simone Gomes Dias de 22 April 2015 (has links)
Submitted by Márcio Ropke (ropke13marcio@gmail.com) on 2017-06-19T11:47:46Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Avaliação do Efeito Antifúngico de Fixadores de Dentaduras Modificados pelo.pdf: 1806073 bytes, checksum: 0b5aa896a1b70dd68b4d7fd54819230d (MD5) / Made available in DSpace on 2017-06-19T11:47:46Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Avaliação do Efeito Antifúngico de Fixadores de Dentaduras Modificados pelo.pdf: 1806073 bytes, checksum: 0b5aa896a1b70dd68b4d7fd54819230d (MD5) Previous issue date: 2015-04-22 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / O uso de próteses totais convencionais configura-se como um importante método de reabilitação bucal devido principalmente a vantagem econômica, sendo a principal queixa quanto ao seu uso a falta de retenção e estabilidade. A fim de melhorar essas características existem no mercado produtos com propriedades adesivas chamados de fixadores de dentadura. O principio de ação desse material resume-se na absorção de líquidos do meio, aumento da viscosidade e aumento da adesividade a mucosa. O presente trabalho foi dividido em três artigos. O artigo 1 objetivou avaliar o estado da técnica e o estado da arte através de revisão sistematizada em banco de patentes e de artigos referentes a fixadores de dentaduras. Para o monitoramento do estado da técnica e da arte, foi realizada uma pesquisa bibliográfica de estudos publicados entre 1960 e 2014, em sete bases de dados MEDLINE ( PubMed), Web of Science , Lilacs , IBECS , Biblioteca Cochrane , Scielo e Scopus . Além disso, os seguintes bancos de dados de patentes foram rastreados: USPTO , EPO , JPO , INPI , Derwent Innovations Index, Patentscope e Questel Orbit . Os dados foram tabulados e analisados pelo Microsoft Office Excel 2013 software e Questel Orbit. Um total de 54 artigos e patentes 78 foram incluídos na análise referente ao monitoramento bibliográfico e tecnológico. Os estudos mais predominantes foram realizados in vivo (n=30), e os tipos de adesivos mais estudados foram em creme ou pó (n=14). Os avanços recentes de tais materiais têm sido mais relacionados com a apresentação comercial do que com os efeitos adicionais de adesivos para próteses dentárias. O artigo 2 objetivou avaliar uma nova metodologia confiável para o teste de adesividade dos fixadores de dentadura frente às variáveis como: meio (saliva artificial, saliva natural e água destilada) e método (imersão e molhamento). Para a validação da metodologia confiável de adesividade dos fixadores este foi definido usando um planejamento experimental com fatores fixos e variáveis. Foi utilizado para tal proposito uma maquina de ensaios universais operando com célula de carga de 100 N e velocidade de 1 mm/min. O método de ensaio estabelecido mostrou que o meio em que o teste é realizado, saliva artificial, água e saliva natural e o método utilizado, imersão ou molhamento, foram determinantes para o resultado de adesividade dos fixadores de dentadura. O artigo 3 objetivou caracterizar e avaliar o efeito do acréscimo de um antifúngico alternativo, derivado de pirazois, em fixadores de dentadura comerciais em três diferentes apresentações (pó, pasta e creme). Os fixadores de dentadura comerciais foram modificados com a inclusão de antifúngicos (Nistatina e Pirazol) em três concentrações por porcentagem em massa diferentes (30%; 3% e 0.3%). A ação antifúngica foi determinada através dos testes de disco difusão e contato direto. O teste de contato direto foi mensurado em 1, 4, 8 e 12 horas. A atividade citotóxica foi avaliada em fibroblastos de camundongos (NIH/3T3) pelo ensaio colorimétrico de redução do MTT. Os resultados obtidos demonstraram que as inclusões dos antifúngicos não afetam a adesividade dos fixadores de dentadura (p>0,05). O teste de disco difusão e de contato direto demonstraram que a inclusão de Nistatina e de Pirazol nos fixadores de dentadura comercial promoveram nestes ação antifúngica frente a Candida albicans. Os fixadores formulados com pirazol se mostraram atividade antifúngica similar aqueles formulados com nistatina. Em relação a citotoxicidade, a concentração mais alta (30%) foi significativamente a mais citotóxica (p<0,05), sendo que as concentrações subsequentes se mostraram com baixa citotoxicidade. Os fixadores com pirazol de comportaram semelhantes a nistatina em relação a citotoxidade nas concentrações 2(3%) e 3(0,3%). Considerando-se as limitações do presente estudo, conclui-se que há possibilidade do uso de fixadores de dentadura como sistema de entrega de antifúngicos comerciais (Nistatina) ou não (pirazol) sendo a segunda concentração (3%) a mais eficiente, que independe da apresentação comercial é menos citotóxica. / The use of conventional dentures still appears as the main oral rehabilitation method of total edentulous patients mainly because the economic advantage of this kind of treatment. Despite these prostheses were made for several years, the main complaint about their use remains the lack of retention and stability. In order to improve these characteristics exists in the market products with adhesive properties called denture adhesives. These denture adhesives have a variety of formulations and commercial presentation, but the principle of action summarized in the absorption of the liquid medium, increased viscosity and increased adhesion to the mucosa. There are controversies in the literature about the effect of these denture adhesives in the oral microbiota and the possibility that these promote accumulation of biofilm which in turn cause chronic infections, such as chronic atrophic candidiasis. This work was divided into three articles. Article 1 aimed to evaluate the state of the art and state of the art through systematic review on bank of patents and articles related to denture adhesives. For monitoring the technique and art state, was performed a literature search of studies published between 1960 and 2014 in seven MEDLINE (PubMed), Web of Science, Lilacs, IBECS, Cochrane Library, SciELO and Scopus. In addition, the following patent databases were screened: USPTO, EPO, JPO, PTO, Derwent Innovations Index, Questel Orbit and Patentscope. Data were tabulated and analyzed using Microsoft Office Excel 2013 software and Questel Orbit. A total of 54 papers and patents 78 were included in the analysis related to bibliographic and technological monitoring. The results showed that the highest number of patents (n = 19) was deposited by Procter & Gamble Company (Cincinnati, Ohio). A total of 54 papers and patents 78 were included in the analysis related to bibliographic and technological monitoring. Furthermore, the most prevalent in vivo studies were performed (n = 30), and the types of adhesives have been most studied cream or powder (n = 14). Recent advances of such materials have been related more to the presentation than for the additional effects of denture adhesives. Article 2 aimed to evaluate a new methodology for the reliable adhesive test of front denture adhesives the variables as a (artificial saliva, natural saliva and distilled water) and method (immersion and wetting). The commercial denture adhesives were modified with the inclusion of antifungals (Pyrazol and nystatin) in three different concentrations in percentages by weight (30%, 3% and 0.3%). To validate the adhesiveness reliable methodology for fixing this was defined using an experimental design with fixed and variable factors. Was used for this purpose universal testing a machine operating with a 100 N load cell and speed of 1 mm / min. The established test method showed that the environment in which the test is performed, artificial saliva, water and natural saliva and the method used, dipping or wetting, was decisive for the outcome of the denture adhesives. It is essential that researchers analyze their methodologies before predicting and say which product is more or less efficient, avoiding misconceptions about them. Article 3 aimed to characterize and evaluate the effect of the addition of an alternative antifungal derived from pyrazoles, in commercial denture adhesives in three different presentations (powder, tape and cream). The antifungal activity was determined by the disk diffusion testing and direct contact. Direct contact test was measured at 1, 4, 8 and 12 hours. The cytotoxic activity was evaluated on mouse fibroblasts (NIH /3T3) using the colorimetric MTT reduction assay. The results showed that the inclusion of antifungals did not affect the adhesion of the denture adhesives (p> 0.05). The disk diffusion test results and demonstrated that direct contact include nystatin and pyrazole in commercial denture adhesives promoted to these antifungal activity against Candida albicans. Adhesives dentures formulated with pyrazol proved similar antifungal those formulated with nystatin. With respect to cytotoxicity, the highest concentration was significantly more cytotoxic (p <0.05), and subsequent concentrations showed low cytotoxicity. The dentures adhesives with pyrazole behaved like nystatin relative cytotoxicity at concentrations of 3% and 0.3%. Considering the limitations of this study, it is concluded that there is possibility of using denture adhesives as delivery system of trade antifungal (Nystatin) or not (pyrazole) and the second concentration (3%) to more efficient, which is independent commercial and less cytotoxic presentation.
797

Síntese e caracterização de tensoativos para uso odontológico / Synthesis and characterization of surfactants for dental use

Ogliari, Aline de Oliveira 27 July 2016 (has links)
Submitted by Márcio Ropke (ropke13marcio@gmail.com) on 2017-06-19T13:16:49Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Síntese e caracterização de tensoativos para uso odontológico.pdf: 1518437 bytes, checksum: 8f1d43b81c8ee411950c9abb45ab6426 (MD5) / Made available in DSpace on 2017-06-19T13:16:49Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Síntese e caracterização de tensoativos para uso odontológico.pdf: 1518437 bytes, checksum: 8f1d43b81c8ee411950c9abb45ab6426 (MD5) Previous issue date: 2016-07-27 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / O objetivo deste estudo foi sintetizar e caracterizar diferentes classes de tensoativos não-iônicos e avaliar a influência nas propriedades e características de materiais de moldagem experimentais a base de polivinilsiloxanos (VPS). Os tensoativos sintetizados e avaliados podem ser utilizados, ainda, para modificação de outros materiais odontológicos. Esta tese foi dividida em dois estudos, apresentados em dois artigos originais. No primeiro estudo, foi realizada a síntese de fluortensoativos com diferentes balanços hidrofílico-lipofílico (HLB) e avaliado o efeito no VPS, enquanto no segundo foi realizada avaliação do desempenho de diferentes tensoativos comerciais não-iônicos do tipo fluorcabono (F), siloxano (S) e hidrocarboneto (H) em uso isolado ou combinado (mais de um tensoativo) adicionados ao VPS. No primeiro estudo, seis fluortensoativos foram sintetizados utilizando polietilenoglicóis com diferentes massas molares (variando de 200 a 1.000.000 g/mol) na porção polar. Os tensoativos sintetizados foram caracterizados e adicionados em concentração de 3% em massa no VPS. No segundo estudo, oito grupos de tensoativos comerciais foram adicionados no VPS, de forma simples ou combinada, em diferentes concentrações: 1%, 3% e 5% em massa. Foram realizadas diferentes metodologias para análise dos tensoativos e dos materiais de moldagem, incluindo espectroscopia no infravermelho, ressonância magnética nuclear de 1H e 19F, tensão superficial, ângulo de contato, viscosidade, capacidade de cópia, resistência mecânica à tração e resistência elástica. Os dados quantitativos foram analisados por Análise de Variância e teste post hoc de Tukey (P<0,05). No primeiro estudo, a síntese dos tensoativos foi confirmada por espectroscopia no infravermelho e ressonância magnética nuclear. Os fluortensoativos, no geral, apresentaram baixa tensão superficial e reduziram a resistência à tração do VPS quando comparados ao grupo controle (sem tensoativo), porém propiciaram excelente capacidade de cópia ao VPS. Foram encontrados diferentes padrões de molhabilidade e obtidos reduzidos ângulos de contato com a água nos grupos FS 200 e FS 400 (fluortensoativos sintetizados com polietilenoglicol de massa molar 200 e 400, respectivamente). A viscosidade foi reduzida com a adição de FS 400 e FS 500; no entanto, foi verificado aumento no tempo de indução do material. No segundo estudo, a menor tensão superficial foi encontrada no grupo que combinou os três tensoativos (F+S+H). Em geral, os grupos que combinaram tensoativos apresentaram menores ângulos de contato e menor viscosidade. O tempo de indução aumentou com o aumento da concentração de tensoativo e nem todos os grupos obtiveram resultados satisfatórios na análise de capacidade de cópia. Os VPS modificados com tensoativos na forma isolada, em geral, apresentaram maior resistência à tração. Em conclusão, a adição de FS 200 e FS 400 melhorou significativamente a molhabilidade do VPS, reduzindo a viscosidade sem alterar o tempo de trabalho significativamente; no entanto, reduziu a resistência à tração. No segundo estudo ficou evidente que a correta seleção do tipo de tensoativo e sua concentração podem melhorar significativamente a molhabilidade dos VPS com pouca interferência em suas propriedades mecânicas. / The aim of this study was to synthesize and characterize different classes of non-ionic surfactants and evaluate their influence on properties and characteristics of experimental impression materials based on vinylpolysiloxanes (VPS). This thesis was divided in two studies, presented as two original articles. In the first study, we synthesized fluorosurfactants with different hydrophilic-lipophilic balances (HLB) and evaluated the effect on the VPS, whereas in the second study we evaluated of the performance of different fluorocabon (F), siloxane (s), and hydrocarbon (H) commercial non-ionic surfactants used alone (one surfactant) or in combination (more than one surfactant) added to the VPS. In the first study, six fluorosurfactants were synthesized using polyethylene glycols of different molar mass (varying from 200 to 1,000,000 g/mol) in the polar portion. The surfactants were characterized and added at a 3 wt% concentration to the VPS. In the second study, eight groups of commercial surfactants were added alone or in combination to the VPS at different concentrations: 1 wt%, 3 wt%, or 5 wt%. Different methods were used to analyze the surfactants and impression materials, including infrared spectroscopy, 1H and 19F nuclear magnetic resonance, surface tension, contact angle, viscosity, detail reproduction tensile strength, and elastic strength. Quantitative data were analyzed using Analysis of Variance and Tukey’s post hoc test (P<0.05). In the first study, the synthesis was confirmed by infrared spectroscopy and nuclear magnetic resonance. The fluorosurfactants, in general, showed low surface tension and reduced the VPS tensile strength when compared to the control group (without surfactant), but yielded excellent copy capacity to the VPS. Different wettability patterns were found and low contact angles were obtained for FS 200 and FS 400 groups (fluorosurfactants synthesized using polyethylene glycol with 200 and 400 molar masses, respectively). The viscosity also decreased with the addition of FS 400 and FS 500; however, an increase in the induction time of the material was observed. In the second study, lower surface tension was found in the group that combined the three surfactants (F+S+H). Overall, the groups that combined surfactants had lower contact angle and lower viscosity. The induction time increased with increased surfactant concentration and satisfactory results on the analysis of copy capacity were not observed for all groups. The VPS modified with surfactants alone, in general, had higher tensile strength. In conclusion, the addition of FS 200 and FS 400 significantly improved wettability of the VPS, reducing viscosity without changing the working time significantly; however, the surfactants reduced the tensile strength. In the second study, it was evident that the correct selection of the surfactant type and its concentration may significantly improve the VPS wettability without major interference on the mechanical properties.
798

Revisão sistemática e caracterização de hidroxiapatita experimental frente a simulação de variáveis de processamento / Systematic review and characterization of experimental hydroxyapatite front simulation processing variables

Oliveira, Héllen de Lacerda 31 March 2016 (has links)
Submitted by Márcio Ropke (ropke13marcio@gmail.com) on 2017-06-21T11:54:02Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Revisão sistemática e caracterização de hidroxiapatita experimental frente a.pdf: 2478739 bytes, checksum: dcf6fc41d4cb572fa54c3b1ff1edb122 (MD5) / Made available in DSpace on 2017-06-21T11:54:02Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Revisão sistemática e caracterização de hidroxiapatita experimental frente a.pdf: 2478739 bytes, checksum: dcf6fc41d4cb572fa54c3b1ff1edb122 (MD5) Previous issue date: 2016-03-31 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / O tecido ósseo apresenta capacidade regenerativa, diretamente dependente do tamanho da lesão óssea, sendo que em casos de lesões mais extensas, pode haver necessidade de utilização de materiais para enxerto ósseo que possam contribuir com esta propriedade. Podemos citar diversos tipos destes materiais, sejam naturais ou sintéticos. Cada um apresentando vantagens e desvantagens na sua utilização, atualmente os fosfatos de cálcio tem se destacado, principalmente a hidroxiapatita, que pode ser utilizado de forma isolada ou como suporte na engenharia tecidual. Dessa forma, o presente trabalho objetivou avaliar a resposta tecidual da hidroxiapatita em estudos animais através de uma revisão sistemática, bem como caracterizar e avaliar microfibras de hidroxiapatita previamente sintetizadas. Para realização da revisão sistemática, a mesma estratégia de busca foi utilizada nas seguintes bases de dados: PubMed (MedLine), ISI Web of Science, Lilacs, Ibecs, BBO, Scopus and Scielo. Inicialmente foram encontrados 4101 potenciais artigos e após remoção de duplicatas e leitura dos títulos e abstracts restaram 75 para leitura na íntegra. Destes, 35 foram incluídos na revisão. No segundo trabalho, uma hidroxiapatita previamente desenvolvida foi caracterizada química e biologicamente após ser submetida a processos de esterilização e indução de contaminação por metais. A hidroxiapatita demonstrou resultados satisfatórios nos trabalhos incluídos na revisão, principalmente quando é utilizada em defeitos maiores que o tamanho crítico. O reparo e regeneração ósseo possuem significativos desafios, tornando-se evidente que o sucesso no desenvolvimento de materiais para este campo de pesquisa trás benefícios duradouros que superam potenciais riscos. Sendo que a hidroxiapatita testada demonstrou estabilidade química e facilidade de esterilização, sem apresentar contaminações em sua composição, o que possibilita o passo seguinte da pesquisa com teste em animais. / Bone tissue has regenerative capacity, directly dependent on the size of the bone injury, and in cases of more extensive lesions, there may be need to use bone graft materials that may contribute to this property. We can cite various types of materials, natural or synthetic. Each has advantages and disadvantages in its use, currently the calcium phosphate has excelled, especially hydroxyapatite, which can be used alone or as support for tissue engineering. Thus, this study aimed to evaluate the biocompatibility of the hydroxyapatite in study animals through a systematic review and characterize and evaluate previously synthesized hydroxyapatite microfibers. For the systematic review, the same search strategy was used in the following databases: PubMed (Medline), ISI Web of Science, Lilacs, IBECS, BBO, Scopus and Scielo. Initially they found 4101 potential articles and after removing duplicates and reading the titles and abstracts remaining 75 to read in its entirety. Of these, 35 were included in the review. In the second study, a previously developed hydroxyapatite has been characterized chemically and biologically after being subjected to sterilization processes and inducing metal contamination. Hydroxyapatite has shown satisfactory results in the studies included in the review, particularly when used in larger defects than the critical size. The repair and bone regeneration have significant challenges, making it clear that the successful development of materials for this field of research behind lasting benefits that outweigh potential risks. The hydroxyapatite tested demonstrated chemical stability and ease of sterilization, without contamination present in the composition, which allows the next step of the research animal testing.
799

Taxa de sucesso e complicações associadas a implantes dentários instalados na região do canal incisivo: revisão sistemática / Success rate and complications associated to dental implants placed at maxillary incisive canal site: a systematic review

Mello, Jerônimo Silva de 15 January 2016 (has links)
Submitted by Márcio Ropke (ropke13marcio@gmail.com) on 2017-06-21T12:11:20Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Taxa de sucesso e complicações associadas a implantes dentários instalados.pdf: 1633997 bytes, checksum: 85a5576924380e0811b404e57cc56896 (MD5) / Made available in DSpace on 2017-06-21T12:11:20Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Taxa de sucesso e complicações associadas a implantes dentários instalados.pdf: 1633997 bytes, checksum: 85a5576924380e0811b404e57cc56896 (MD5) Previous issue date: 2016-01-15 / Sem bolsa / Objetivo: Realizar uma revisão sistemática da literatura através da seguinte pergunta norteadora: qual a taxa de sucesso dos implantes dentários instalados na região do canal incisivo e suas complicações? Materiais e Métodos: Uma revisão sistemática da literatura foi realizada nas seguintes bases de dados: Pubmed, Scopus, Web of Science. Os artigos que utilizaram o procedimento de esvaziamento do canal incisivo ou lateralização do feixe vásculo-nervoso concomitante ou não a instalação de implante dentário e procedimento enxertivo, realizados em seres humanos, sem restrição de idioma nem tempo, foram incluídos. A análise qualitativa dos estudos clínicos foi realizada através de um questionário criado pelo Joanna Briggs Institute. Resultados: Apenas 1 estudo clínico retrospectivo e 1 longitudinal foram encontrados. De acordo com os 10 artigos incluídos na revisão final, 84 implantes foram instalados nesta região, e a taxa de sucesso dos implantes instalados variou entre 84,6 e 100%. Em relação as complicações, 3 artigos relataram perda sensorial transitória, sendo 2 em pacientes que foram submetidos a esvaziamento do canal incisivo e 1 em que ocorreu a lateralização do feixe vásculo-nervoso. A perda sensorial permanente na região de mucosa palatina foi relatada em apenas 1 artigo que realizou o procedimento de lateralização do feixe vásculo-nervoso. De acordo com a análise qualitativa dos artigos avaliados, nenhum alcançou alta qualidade, 4 apresentaram qualidade moderada e 1 baixa qualidade. Conclusão: Apesar de uma alta taxa de sucesso ter sido descrita nos artigos selecionados nesta revisão, recomenda-se cautela na utilização de implantes dentários instalados na região do canal incisivo em virtude do número reduzido de artigos disponível sobre intervenções cirúrgicas utilizando ambas as técnicas aqui descritas. Quanto às complicações, não existem parâmetros que permitam prever a possibilidade ou não da ocorrência de alteração sensorial assim como a amplitude do dano (agravo permanente x agravo transitório) utilizando as técnicas de esvaziamento ou lateralização. / Aim: The aim of the present study was to answer the question: what is the success rate of dental implants placed at maxillary incisive canal zone and its complications? Material and Methods: A systematic literature review was conducted searching at PubMed, Scopus and Web of Science databases. Articles that applied incisive canal deflation or lateralization technique of the neurovascular bundle associated or not to dental implant installation and graft techniques were included at this article. Also, all types of studies, conducted at human beings and without time and language delimitation. The qualitative analysis of clinical trials was conducted in accordance with Joanna Briggs Institute questionnaire. Results: Only 1 retrospective and 1 longitudinal clinical trial was found. In accordance to the 10 articles included at final screening, 84 implants were installed at this site, and the success rate for the implants ranged between 84,6 and 100%. Regarding the complications, 3 articles reported temporary sensory loss at patients (2 articles at patients who underwent incisive canal deflation and 1 article at patients who underwent lateralization technique of the neurovascular bundle). A permanent sensory loss at anterior palatal mucosa was reported in 1 article in patients who underwent lateralization technique. According to qualitative analysis of the selected articles evaluated, none reached high quality, 4 presented moderate quality and 1 exhibited low quality. Conclusion: Although a high rate of success was described in the selected articles, it is recommended precaution when dental implants are installed at incisive canal zone due to the low number of articles available using both surgical techniques. Regarding to the complications, there are no parameters for predicting whether or not the occurrence of sensory disturbance as well as the extent of damage (permanent disturbance x transient disturbance) using the incisive canal deflation or lateralization technique.
800

Metacrilato piperonílico: coiniciador copolimerizável para composição de sistemas de polimerização fotoiniciada / Piperonyl methacrylate: coinitiator copolymerizable for the composition of system of polymerization photoinitiated

Moreira, Andressa Goicochea 29 March 2017 (has links)
Submitted by Márcio Ropke (ropke13marcio@gmail.com) on 2017-07-12T12:38:06Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Metacrilato piperonílico coiniciador copolimerizável para composição de.pdf: 1224200 bytes, checksum: aaa0f95ab36381591948e0528869f28c (MD5) / Made available in DSpace on 2017-07-12T12:38:06Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Metacrilato piperonílico coiniciador copolimerizável para composição de.pdf: 1224200 bytes, checksum: aaa0f95ab36381591948e0528869f28c (MD5) Previous issue date: 2017-03-29 / Sem bolsa / A evolução dos materiais odontológicos vem contribuindo para que se consiga al-cançar a excelência em procedimentos estéticos. Diversos fatores clínicos motivam novos estudos para desenvolvimento de materiais que consigam atingir proprieda-des ópticas, mecânicas e biológicas semelhantes ao elemento dental. Assim, esta pesquisa busca contribuir para a evolução desses materiais por meio de estudos in vitro. Portanto os objetivos deste trabalho foram realizar a síntese de uma molécula, o metacrilato piperonílico, por meio de uma rota de sintese alternativa à utilização do cloreto de metacriloila, com tocixidade conhecida, e analisar se essa moléula possui potencial de atuação como um coiniciador alternativo copolimerizável para composi-ção de sistemas de polimerização radicalar fotoiniciada com tecnologia de alto de-sempenho e biocompatibilidade. Para a síntese do metacrilato piperonílico, o álcool piperonílico foi esterificado utilizando o anidrido metacrilato. O produto obtido foi pu-rificado e posteriormente submetido à ressonância magnética nuclear protônica e espectroscopia no infravermelho para confirmação da estrutura. Adesivos convenci-onais foram desenvolvidos utilizando uma resina adesiva modelo, composta por 50% de bisfenol a glicidil metacrilato (Bis-GMA), 25% de 2-hidroxietil metacrilato (HEMA) e 25% de trietilenoglicol dimetacrilato (TEGDMA). Canforoquinona (CQ) na concen-tração 1% molar foi utilizada como fotoiniciador da polimerização da resina modelo, a qual foi adicionada de diferentes coiniciadores constituindo os seguintes grupos experimentais: metacrilato piperonílico (PipeM Adesivo) e EDAB (EDAB Adesivo) constituindo sistemas binários de fotoativação. Adicionalmente um grupo com adesi-vo de referência comercial Scotch Bond Multi Purpouse - 3M (SBMP Adesivo) foi avaliado. As propriedades físico-químicas, mecânicas, microbiologicas e biológicas do polímero formado pelos adesivos experimentais foram avaliadas utilizando as metodologias de cinética e taxa de polimerização, resistência à mini-flexão, módulo de elasticidade, sorção e solubilidade, resistência de união ao microcisalhamento 10 (MPa) em esmalte e dentina bovina, caracterização da camada híbrida em micros-cópio eletrônico de varredura (MEV), teste antimicrobiano de contato direto modifi-cado e avaliação da sua citotoxidade. Os resultados obtidos foram tabulados e a análise estatística realizada de acordo com o ensaio. O PipeM adesivo apresentou maior grau de conversão, menor sorção e solubilidade em água quando relacionado aos demais grupos. O grupo PipeM foi semelhante apenas ao grupo EDAB no teste de resistência de união ou microcisalhamento em dentina. Em todos os outros tes-tes, os grupos foram semelhantes (p <0,05). A porcentagem de viabilidade celular avaliada após 24h mostrou que os grupos experimentais foram semelhantes à refe-rência comercial apresentando viabilidade celular próxima de 100%. Em suma o me-tacrilato piperonílico apresentou desempenho semelhante ou superior à amina terci-ária, com a vantagem de apresentar maior biocompatibilidade em função de seu po-tencial de copolimerização, representando ser um coiniciador alternativo para com-posições fotopolimerizáveis. / The evolution of dental materials has been contributing to their success in cosmetic procedures. Several clinical factors motivate new studies to develop materials that achieve optical, mechanical and biological properties similar to the dental element. Thus, this research seeks to contribute to the evolution of these materials through in vitro studies. Therefore, the objectives of this work are to carry out the synthesis of a molecule, piperonyl methacrylate, by means of an alternative route to the use of methacryloyl chloride, with known toxicity, and to analyze if this molecule has poten-tial of acting as an alternative copolymerizable coinitiator for the composition of radi-cal polymerization systems photoinitiated with technology of high performance and biocompatibility. For the synthesis of piperonyl methacrylate, piperonyl alcohol was esterified using methacrylic anhydride. The product obtained was purified and sub-sequently subjected to proton magnetic resonance and infrared spectroscopy to con-firm the structure. Conventional adhesives were developed using an adhesive resin model, composed of 50% bisphenol A glycidyl methacrylate (Bis-GMA), 25% 2-hydroxyethyl methacrylate (HEMA) and 25% triethyleneglycol dimethacrylate (TEGDMA). Canforquinone (CQ) at 1 mol% concentration was used as a photoinitia-tor of the polymerization of the model resin, which it was added with different co-initiators constituting the following experimental groups: piperonyl methacrylate (Pi-peM Adhesive) and EDAB (EDAB Adhesive), constituting binary photoactivation sys-tems. In addition, the Scotch Bond Multi Purpose-3M commercial reference adhesive (SBMP Adhesive) was evaluated. The physicochemical, mechanical, microbiological and biological properties of the polymer formed by the experimental adhesives were evaluated using polymerization kinetics methodologies, mini-flexural strength, modu-lus of elasticity, water sorption and solubility, enamel and dentin micro-shear bond strength (MPa) and performed the characterization of the hybrid layer under scanning electron microscope (SEM), Modified direct contact antimicrobial test and evaluation 12 of its cytotoxicity. The results obtained, were tabulated and the statistical analysis performed according to the assay. The PipeM adhesive showed a higher degree of conversion, lower sorption and solubility in water when related to the other groups. The PipeM group was similar only to the EDAB group in the bond strength test or dentin microcracking. In all other tests, the groups were similar (p <0.05). The percentage of cell viability evaluated after 24h showed that the experimental groups were similar to the commercial reference, presenting cell viability close to 100%. In summary, the piperonyl methacrylate presented similar or superior perfor-mance to the tertiary amine, with the advantage of presenting greater biocompatibil-ity as a function of its copolymerization potential, being an alternative co-initiator for photopolymerizable compositions.

Page generated in 0.0529 seconds