• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2304
  • 155
  • 150
  • 150
  • 148
  • 109
  • 35
  • 35
  • 24
  • 17
  • 17
  • 12
  • 7
  • 5
  • 2
  • Tagged with
  • 2362
  • 1247
  • 1039
  • 886
  • 534
  • 523
  • 493
  • 433
  • 425
  • 347
  • 234
  • 192
  • 180
  • 166
  • 163
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
821

Avaliação da osteointegração de implantes colocados em defeitos ósseos, utilizando diferentes técnicas de regeneração óssea : estudo experimental

Guerra, Isabel Maria Lopes January 2007 (has links)
No description available.
822

Análise mecânica e da deformação da conexão de implantes de hexágono externo após a instalação com um novo tipo de montador /

Oliani, Marcelo Gallo. January 2019 (has links)
Orientador: Lafayette Nogueira Junior / Banca: Tarcísio José de Arruda Paes Junior / Banca: Fernanda de Cassia Papaiz Gonçalves / Banca: Rodrigo Máximo de Araújo / Banca: Jean Soares Miranda / Resumo: A sobrecarga do hexágono durante a inserção dos implantes dentários de hexágono externo pode gerar danos irreversíveis ao mesmo ocasionando problemas futuros na reabilitação. Sendo assim, esse trabalho teve por objetivo avaliar a deformação e resistência ao contra-torque dos hexágonos com o uso de um montador modificado proposto pelo autor para inserção dos implantes tipo hexágono externo (HE) tendo como hipótese de que o montador modificado apresente resultados diferentes do montador padrão. Para isso, 44 implantes foram divididos em dois grupos, controle (montador normal MN; n=12) e o teste (montador modificado MM; n=12), e foram submetidos ao teste de torção seguindo os parâmetros da norma ISO 13498:2013. Em seguida, a deformação dos hexágonos e possíveis deformações causadas às roscas internas dos implantes foram analisadas, respectivamente, de forma qualitativa por meio de microscopia eletrônica de varredura. Já para o teste de fadiga, controle (MN; n=10) e teste (MM; n=10), os parâmetros utilizados foram da norma ISO 14801:2007. Ao final de 1,2 x 106 (4Hz) ciclos, o valor de destorque dos pilares foi registrado. A desadaptação da junta pilar/implante foi avaliada qualitativamente por meio da microscopia MEV. Como resultados pudemos observar maior manutenção da estrutura da conexão pelo grupo MM comparado ao grupo MN, sugerindo-se que o grupo MM apresentaram comportamento mais seguro e previsível quando comparado ao grupo MN / Abstract: Hexagon overload during the insertion of external hexagon dental implants can lead to irreversible damage, leading to future problems in rehabilitation. Thus, this study aimed to evaluate the deformation and reverse torque resistance of hexagons with the use of a modified mount proposed by the author for insertion of external hexagon (HE) implants with the hypothesis that the modified mount presents different results compared to the default assembler. For this, 44 implants were divided into two groups, control (normal mount MN; n = 12) and the test (modified mount MM; n = 12), and were submitted to torsion testing following the parameters of ISO 13498: 2013. Then, the deformation of the hexagons and possible deformations caused to the internal threads of the implants were analyzed qualitatively, respectively by scanning electron microscopy. For the fatigue test, control (MN; n = 10) and test (MM; n = 10), the parameters used were from ISO 14801: 2007. At the end of 1.2 x 106 (4Hz) cycles, the abutment value of the abutments was recorded. Abutment of the abutment / implant joint was qualitatively evaluated by SEM microscopy. As a result we could observe a better maintenance of the connection structure by the MM group compared to the MN group, suggesting that the MM group presented a safer and more predictable behavior when compared to the MN group / Doutor
823

Implantes de diâmetros reduzidos instalados em diferentes níveis ósseos influenciam a biomecânica de próteses unitárias na região anterior maxilar ? /

Mestrener, Leandro Rahal. January 2019 (has links)
Orientador: Fellippo Ramos Verri / Resumo: O objetivo deste estudo foi avaliar a distribuição de tensão e deslocamento em implantes de diâmetro reduzido em reabilitações unitárias em região maxilar anterior, variando o posicionamento do implante (ao nível ósseo e 1,5 mm infra-ósseo), através do método de elementos finitos tridimensionais (MEF-3D). Quatro modelos 3D representando uma hemisecção do lado direito da região anterior da maxila foram simulados com a presença de coroa cimentada sobre implante (cone morse) de 10mm de comprimento, variando-se o diâmetro do implante (2,9 mm e 3,5 mm) e a instalação dos implantes no tecido ósseo em rebordo alveolar de 4,5 mm de espessura. O modelo ósseo tridimensional foi construído por recomposição tomográfica com uso dos softwares Invesalius e Rhinoceros 3D. O implante e os componentes foram modelados a partir de modificações do formato original no programa SolidWorks e finalizados no Rhinoceros, bem como o desenho da coroa simulada. A discretização dos modelos foi feita no software ANSYS 19.2, incluindo caracterização dos materiais, contatos, elaboração das malhas, condições de carregamento (178N em direção de 0, 30 e 60 graus em relação ao longo eixo do implante) e de contorno (com restrição em direção x, y, z nas secções laterais dos modelos). Os resultados mostraram comportamento biomecânico similar, com diminuição dos níveis de deslocamento e estresse para implantes de 3,5 mm e implantes infra-ósseos, muito embora os valores obtidos estiveram dentro de valores fisiológicos... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Abstract: The Aim of this study was to evaluate the distribution of stress on implants of narrow diameter, in single unit cemented crowns in the anterior maxillary region, varying the position of the implant (at the bone level and 1.5 mm infra-osseous), through the 3D finite element analysis (3D-FEA). Four 3D models representing a right hemisection of the anterior maxillary region were simulated with the presence of a cemented crown over a 10mm long implant (morse cone), with the implant diameter varying among 2.9 mm and 3.5 mm in an simulated alveolar ridge of 4,5mm thickness. The bone of 3D models was simulated by tomographic recomposition using the software Invesalius and Rhinoceros 3D. The implant and components were modeled from modifications of the original design in the SolidWorks software and modeled in the Rhinoceros, as well as the design of the simulated crown. The discretization of the models was done in the ANSYS 19,2 software, including characterization of materials, contacts, meshes, loading conditions (178N towards 0, 30 and 60 degrees in relation to the implant long axis) and boundary conditions in the x, y, z direction in the lateral sections of the models). The results of dislodgment and von Mises showed similar maps distribution, decreasing dislodgment and stress in implants of 3,5mm diameter and in infra-osseous position, besides these results were inside physiologic values. It was possible to conclude that 2.9mm implants were no more biomechanically favo... (Complete abstract click electronic access below) / Mestre
824

Influência do tamoxifeno na remodelação óssea periimplantar /

Fiorin, Luiz Guilherme. January 2019 (has links)
Orientador: Juliano Milanezi de Almeida / Resumo: O propósito do presente estudo foi avaliar a remodelação óssea de implantes ósseointegrados instalados em tíbias de ratos modificados ou não sistemicamente pelo tamoxifeno. Foram utilizadas 72 ratas, os animais receberam ovariectomia bilateral, instalação dos implantes em tíbia bilateralmente e após 6 semanas,foram aleatoriamente distribuídas em dois grupos experimentais(n=36), Grupo SS: administração de solução salina e Grupo TAM: administração de citrato de tamoxifeno, via gavagem por todo o período experimenta. Doze animais de cada grupo foram eutanasiados aos 30, 60 e 90 dias após a administração da primeira dose das soluções, as tíbias direita e esquerda foram coletadas, e aleatóriamente processadas com desmineralização para as análises histológicas, imunoistoquímicas e para a análise de porcentagem de tecido ósseo neoformado(PTON) e sem desmineralização para análise do contato osso/implante(BIC) e para as análises de Microscopia Eletrônica de Varredura (MEV) e de Espectroscopia Dispersiva de Raio-x (EDS). Os dados obtidos foram submetidos à análise estatística (p<0,05) em programa computacional especializado. Com relação ao contato osso implante, o grupo TAM, apresentou maior BIC em todos os períodos experimentais quando comparado com o grupo SS. O grupo TAM apresentou também maior PTON em todos os períodos experimentais quando comparado com o grupo SS. A análise histológica dos tecidos periimplantares mostrou que o grupo TAM apresentou características histológicas que ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The purpose of the present study was to evaluate the bone remodeling of osseointegrated implants installed in tibias of rats modified or not systemically modified by tamoxifen. Seventy-two female rats were used, the animals received bilateral ovariectomy, tibial implant placement bilaterally and after 6 weeks were randomly assigned to two experimental groups (n = 36). Group SS: received saline administration and Group TAM: received administration of tamoxifen citrate via gavage throughout the experimental period. Twelve animals from each group were euthanized at 30, 60 and 90 days after administration of the first dose of the solutions. The right and left tibias were collected, processed with demineralization for histológical, immunohistochemical and percentage analysis of neoformed bone tissue. (PTON) and without demineralization for bone / implant contact analysis (BIC) and for Scanning Electron Microscopy (SEM) and Xray Dispersive Spectroscopy (EDS). The data obtained were submitted to statistical analysis (p <0.05) in a specialized computer program. With regard to implant bone contact, the TAM group presented higher BIC in all experimental periods when compared to the SS group. The TAM group also presented higher PTON in all experimental periods when compared to the SS group. Histológical analysis of periimplant tissues showed that the TAM group presented histológical characteristics that were similar to the control group, however, with a larger amount of peri-implant bon... (Complete abstract click electronic access below) / Mestre
825

Utilização do extrato de óleo insaponificável de abacte e soja na osseointegração. Avaliação biomecânca, radiográfica, histológica e histomorfométrica em ratos

Paula, Luiz Guilherme Freitas de [UNESP] 28 March 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:47Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-03-28Bitstream added on 2014-06-13T20:26:55Z : No. of bitstreams: 1 paula_lgf_me_arafo.pdf: 746134 bytes, checksum: 5963765673b2f4be8b648c4119483545 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este estudo avaliou a influência da utilização do extrato de óleo insaponificável de abacate e soja na osseointegração de implantes. Foram utilizados implantes de titânio com 4 mm de comprimento por 2.2 mm de espessura, instalados nas tíbias de ratos. Os 30 ratos foram divididos randomicamente em três grupos: 1- instalação de implantes e administração de soro fisiológico; 2- administração do extrato de óleo insaponificável de abacate e soja 7 dias antes dos implantes; 3- instalação dos implantes e administração do extrato de óleo insaponificável de abacate e soja. O medicamento foi administrado por gavagem diariamente, durante 60 dias até o sacrifício. A avaliação se deu através de exames radiográficos (por densidade óssea/milímetro de alumínio), realizados no dia da instalação dos implantes e no dia do sacrifício; análise biomecânica; análise histomorfométrica de contato osso-implante e preenchimento ósseo entre as roscas dos implantes (regiões medulares e corticais ósseas); e análise histológica. O teste de Shapiro-Wilk foi aplicado para a verificação da normalidade dos dados, e o teste paramétrico ANOVA complementado pelo teste de Tukey foi utilizado para comparação dos dados. Todos os testes foram aplicados com nível de significância de 95%. Os resultados obtidos da análise radiográfica nas imagens iniciais, o grupo II apresentou menores valores de densidade tanto nas regiões de osso cortical como medular comparados aos grupos I e III. Entretanto, as razões de densidade radiográfica do osso nas imagens finais foram sem diferença estatística para todos os grupos. Na análise biomecânica não houve diferenças estatísticas entre os grupos. Na histologia descritiva e histometria, o grupo I apresentou menor contato osso-implante na área da cortical óssea em relação aos demais grupos... / This study evaluated the influence of the use of oil extract of avocado and soybean unsaponifiables on osseointegration of implants. Titanium implants used were 4 mm long by 2.2 mm thick, installed in the rat tibia. The 30 rats were randomly divided into three groups: 1 - implant placement and administration of saline, 2 - Administration of the extract oil of avocado and soybean unsaponifiable 7 days before the implants, 3 - implant placement and administration of the extract oil Avocado and soybean unsaponifiables. The drug was administered by gavage daily for 60 days until sacrifice.The evaluation was made by radiographic examination (for bone density / mm of aluminum), performed on the day of implant placement and the day of sacrifice, biomechanical, histomorphometric analysis of bone-implant contact and bone fill between the threads of the implants ( medullary and cortical bone regions), and histological analysis. The Shapiro-Wilk test was applied to verify the normality of the data, and parametric test ANOVA complemented by Tukey's test was used to compare the data. All tests were applied with a significance level of 95%. The results of radiographic images in the initial group II had lower density in the regions of cortical bone marrow as compared to groups I and III. However, the reasons for radiographic density of bone in the final images were no statistically significant difference for all groups. In biomechanical analysis no statistical differences between groups. Histologically descriptive and histometric analysis, group I showed lower bone-implant contact in the area of cortical bone in relation to other groups. The extract oil unsaponifiable of avocado and soybean had a positive influence on osseointegration of implants
826

Avaliação da efetividade de cimentos resinosos auto-adesivos aplicados sob diferentes pré-tratamentos da dentina radicular na resistência adesiva de pinos de fibra de vidro

Lima, Luiz Rafael Calixto [UNESP] 12 March 2013 (has links) (PDF)
Made available in DSpace on 2014-08-13T14:50:34Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-03-12Bitstream added on 2014-08-13T18:01:15Z : No. of bitstreams: 1 000732205_20140909.pdf: 527845 bytes, checksum: a4c9483a6f8f4f270ac1d61032aec827 (MD5) Bitstreams deleted on 2014-10-03T16:24:43Z: 000732205_20140909.pdf,Bitstream added on 2014-10-03T16:27:41Z : No. of bitstreams: 2 000732205_20140909.pdf.txt: 17075 bytes, checksum: 2d10283196b7e27311acd4c2cfff812d (MD5) 000732205.pdf: 890728 bytes, checksum: 73e31941709b20f0f746950e7ee144ad (MD5) Bitstreams deleted on 2014-10-03T16:33:18Z: 000732205.pdf,Bitstream added on 2014-10-03T16:43:31Z : No. of bitstreams: 2 000732205_20140909.pdf.txt: 17075 bytes, checksum: 2d10283196b7e27311acd4c2cfff812d (MD5) 000732205.pdf: 890728 bytes, checksum: 73e31941709b20f0f746950e7ee144ad (MD5) Bitstreams deleted on 2014-10-03T16:48:57Z: 000732205.pdf,Bitstream added on 2014-10-03T16:49:48Z : No. of bitstreams: 1 000732205.pdf: 890728 bytes, checksum: 73e31941709b20f0f746950e7ee144ad (MD5) Bitstreams deleted on 2014-10-27T11:47:13Z: 000732205.pdf,Bitstream added on 2014-10-27T11:48:06Z : No. of bitstreams: 1 000732205.pdf: 890728 bytes, checksum: 73e31941709b20f0f746950e7ee144ad (MD5) / A retenção de pinos pré-fabricados de fibra de vidro utilizados na restauração de dentes com tratamento endodôntico é baseada na sua união às superfícies das paredes do canal radicular por meio dos agentes de fixação resinosos. Os cimentos resinosos auto-adesivos surgiram recentemente com o objetivo de simplificar o procedimento de cimentação, porém seu desempenho clínico ainda é controverso na literatura. Assim, o propósito desse trabalho é avaliar a efetividade de cimentos autoadesivos sob diferentes condições de tratamento da dentina na resistência à extrusão de pinos de fibra de vidro cimentados intrarradicularmente. Foi avaliada a resistência adesiva (push-out) de pinos de fibra de vidro utilizando cimentos resinosos auto-adesivos e, diferentes substâncias para o tratamento dentinário (ácido poliacrílico 11,5%; EDTA 17% e hipoclorito de sódio) previamente ao procedimento de cimentação. Foi avaliado também o tipo de falha entre o pino/cimento/dentina através de microscopia óptica. Foram utilizados 216 unidades experimentais, em forma de discos com aproximadamente 1 mm de espessura, retirados de 72 raízes bovinas restauradas com retenções intra-radiculares. Foi utilizada uma máquina de ensaios universais MTS 810 Material Test System, à velocidade de 0,5 mm/min-1, com célula de carga de 50 Kg, para avaliação da resistência push-out nos diferentes terços de cada corpo-de-prova. Os valores de resistência em kgf, foram convertidos para Mpa. Os dados foram submetidos ao teste kruskall wallis com post-hoc com teste dunn, com nível de significância de 5%. Os resultados mostraram que o pré-tratamento dentinário não influenciou na resistência adesiva, e que o cimento auto-adesivo RelyX U100 parece ser uma opção viável na cimentação de pinos de fibra. / The retention of prefabricated fiberglass posts used in the restoration of endodontically treated teeth is dependent on their bond between the surface of the post and the root canal walls by means of resin cements. The self-adhesive resin cements have recently introduced to simplify the procedure for cementing, but their clinical performance is still controversial in the literature. Thus, the objective of this study is to evaluate the effectiveness of self-adhesive cements under different pretreatment of dentin in the resistance to extrusion of fiberglass posts. Prior to cementing procedure, the pre-treatment of dentin was performed with 11.5% polyacrylic acid, 17% EDTA or sodium hypochlorite. The type of failure between the post/cement/dentin was evaluated by steriomicroscopy. Two hundred and sixteen bovine dentin discs were used. The disks had approximately 1 mm of thickness and they were taken from 72 bovine roots restored with intraradicular retentions. It was employed a universal testing machine MTS 810 Material Test System at a speed of 0.5 mm/min-1 with a load cell of 50 kg to evaluate the push-out resistance in different thirds of each sample . The values of resistance in kgf were converted to Mpa. Data were submitted to Kruskal-Wallis test with Dunn post-hoc test with significance level of 5%. The results showed that pre-treatment had no effect on dentin bond strength, and that the self-adhesive cement RelyX U100 appears to be a viable option in the cementation of fiber post.
827

Influência do ácido peracético e do hipoclorito de sódio na limpeza dos canais radiculares instrumentados com diferentes sistemas rotatórios /

Jeronymo, Raffaela Di Iorio. January 2012 (has links)
Orientador: Ana Paula Martins Gomes / Banca: Marcia Carneiro Valera / Banca: Cláudio Antonio Talge Carvalho / Banca: Sandra Márcia Habitante / Banca: Danilo Mathias Zanello Guerisoli / Resumo: O objetivo deste estudo foi avaliar o efeito do ácido peracético e do hipoclorito de sódio nas paredes do canal radicular após instrumentação rotatória. Foram utilizadas 80 raízes unirradiculares humanas com comprimento padronizado em 16 mm e que tiveram seus canais instrumentados por 2 sistemas rotatórios: Biorace e Mtwo. Os grupos experimentais foram subdivididos de acordo com a substância química utilizada (n=10): G1.1- Solução de hipoclorito de sódio a 5,25% + Sistema Biorace; G1.2- Solução de hipoclorito de sódio a 5,25% + Sistema Mtwo; G2.1- Solução de ácido peracético a 0,5% + Sistema Biorace; G2.2- Solução de ácido peracético a 0,5% + Sistema Mtwo; G3.1- Solução de ácido peracético a 2% + Sistema Biorace; G3.2- Solução de ácido peracético a 2% + Sistema Mtwo; G4.1 - Solução salina fisiológica + Sistema Biorace; G4.2 - Solução salina fisiológica + Sistema Mtwo. Finalizada a instrumentação, as raízes foram clivadas e as paredes dentinárias foram avaliadas em MEV com aumento de 500x e 2000x nos terços apical, médio e cervical. A área analisada foi quantificada pelo número total de túbulos dentinários presentes e pela porcentagem de túbulos abertos na região avaliada. Os dados relativos à porcentagem de túbulos abertos foram submetidos à análise estatística utilizando os testes de ANOVA e Tukey 5%. Os resultados mostraram maior quantidade de túbulos dentinários abertos no G1.1 e menor quantidade de túbulos dentinários abertos no grupo G2.2 com diferenças estatisticamente significantes. Em todos os grupos a limpeza obtida nos terços cervical e médio foi superior ao terço apical. Pôde-se concluir que a limpeza obtida no terço apical foi inferior em todos os grupos avaliados; que a limpeza dos canais radiculares foi diferente estatisticamente entre os grupos G1.1 e G2.2 e nenhuma técnica... (Resumo completo, clicar acesso eletrônico / Abstract: The aim of this study was to evaluate the effect of peracetic acid and sodium hypochlorite in the root canal walls after rotary instrumentation. We used 80 single rooted human roots with standardized length of 16 mm and their canals were instrumented by two rotary systems: Biorace and Mtwo. The experimental groups were subdivided according to the chemical substance used (n = 10): G1.1-sodium hypochlorite solution 5.25% + System Biorace; G1.2-solution of sodium hypochlorite 5.25% + System Mtwo; G2.1-solution of peracetic acid 0.5% + System Biorace; G2.2-Solution 0.5% peracetic acid system Mtwo +; G3.1-peracetic acid solution at 2% + Biorace system; G3.2-peracetic acid solution at 2% + Mtwo system; G4.1 - saline + physiological System Biorace; G4.2 - + physiological saline Mtwo system. After instrumentation, the roots were cleaved and the dentinal walls were evaluated by SEM with an increase of 500x and 2000x in the apical, middle and cervical. The analyzed area was quantified by the total number of dentinal tubules and the present percentage of open tubules in the region evaluated. Data on percentage of open tubules were statistically analyzed using ANOVA and 5% Tukey. The highest number of open dentinal tubules in G1.1 and fewer open tubules G2.2 in the group with statistically significant differences. In all groups obtained in cleaning cervical and middle thirds was higher than that achieved in the apical third. It was concluded that the cleaning obtained in the apical third were lower in all groups studied, the cleaning of root canals was statistically different between groups G1.1 and G2.2 and no instrumentation... (Complete abstract click electronic access below) / Doutor
828

Avaliação clínica do grau de paralelismo obtido no preparo de planos de guia de dentes suportes de prótese parcial remóvivel, utilizando paralelizador intrabucal /

Borges, Alexandre Luiz Souto. January 2005 (has links)
Orientador: José Eduardo Junho de Araújo / Banca: Arlindo Abreu de Castro Filho / Banca: Paulo Sérgio Mutarelli / Banca: Carlos Rocha Gomes Torres / Banca: Eduardo Shigueyuki Uemura / Resumo: O objetivo do presente estudo foi avaliar a eficiência do paralelizador intrabucal ParalAB como método de transferência de planos de guia e a influência do tipo de arcada e posição dos dentes suportes nos preparos realizados por estudantes e profissionais. Foram selecionados 92 modelos de trabalho de pacientes em tratamento na clínica de Prótese Parcial Removível, nos quais foram preparados 321 planos de guia por diferentes operadores utilizando o ParalAB, divididos em dois grupos: grupo 1: profissionais (n=44) e grupo 2: alunos (n=48). Esses grupos foram subdivididos em subgrupos de acordo com a arcada (S - Superior e I - Inferior) e posição (A - Anterior e P - Posterior). A mensuração da inclinação da superfície preparada foi realizada de maneira indireta utilizando um relógio apalpador para registro do deslocamento que proporcionava um cálculo do valor angular em relação à trajetória de inserção escolhida. O valor médio obtido para os grupos 1 e 2 foram respectivamente 0,64 ± 0,36º e 0,77 ± 0,45º, para os subgrupos S e I foram 0,78 ± 0,47º e 0,64 ± 0,34º e para ambos os subgrupos A e P foram 0,71 ± 0,41o. A aplicação do teste estatístico ANOVA (5%), revelou que os efeitos tipo de operador e posição bem como as interações não apresentaram diferença significante já para o tipo de arcada houve diferença significante. Ao se aplicar o teste de Tukey (5%) para o tipo de arcada obteve-se 0,59 ± 0,32o para o grupo 1I, 0,70 ± 0,38o para o 1S, 0,69 ±0,42o para o 2I e 0,78 ± 0,43o para o 2S. Pode-se concluir que o aparelho ParalAB foi capaz de produzir planos de guia com baixo desvio em relação à trajetória de inserção e de restringir a influência da experiência do operador na qualidade do preparo final de planos de guia para os dentes suportes da maxila e que a quantidade de retoques foi muito baixa / Abstract: The aim of this study was to evaluate the efficiency of the ParalAB intraoral device as a transference method of guide planes and to verify the influence of the arch and position of the abutment teeth on preparations produced by students and dentists. 321 guide planes were prepared by different collaborators using the ParalAB device on 92 casting models deriving from patients of partial removable denture dental clinic. The preparations were divided in two groups: group 1: dentists (n=44) and group 2: students (n=48). These groups were subdivided in subgroups according to the arch (S - maxilla and I - mandible) and position (A - anterior teeth and P - posterior teeth). The inclinations of guide planes were indirectly measured by means of an Order Dial Indicator that provided the angular deviation related to the path of insertion. The mean value obtained for the groups 1 and 2 were respectively 0,64 ± 0,36º and 0,77 ± 0,45º, for the subgroups S and I were 0,78 ± 0,47º and 0,64 ± 0,34º and for both the subgroups A and P were 0,71 ± 0,41o. The ANOVA test (5%) revealed no significant differences for the effects operator and position, as well as their interactions, and for the arch type, there was significant difference. The results of Tukey test (5%) for the type of arch were 0,59 ± 0,32o for the group 1I, 0,70 ± 0,38o for 1S, 0,69 ± 0,42o for 2I and 0,78 ± 0,43o for 2S. It was concluded that the ParalAB device was able to produce guide planes with low deviations related to the path of insertion and to reduce the influence of the professional experience on the quality of preparations made on maxilla and that few new preparations were needed / Doutor
829

Avaliação da resistência de união em dentina submetida ao desafio erosivo: adesão ao substrato tratado com CPP-ACP e irradiado ou não com laser Nd:YAG /

Kamozaki, Maria Beatriz Beber. January 2012 (has links)
Orientador: Clovis Pagani / Banca: Sérgio Eduardo de Paiva Gonçalves / Banca: Ricardo Amore / Resumo: O estudo avaliou a influência do CCP-ACP (casein phosphopeptide - amorphous calcium phosphate) e CPP-ACP associado ao NaF, na resistência de união à dentina submetida ao desafio erosivo por bebida ácida, com ou sem irradiação por laser Nd:YAG. Foram utilizados 60 molares humanos, os quais tiveram a porção coronária seccionada mesio-distalmente, obtendo dois espécimes. Após a exposição da dentina, os espécimes foram embutidos em resina acrílica quimicamente ativada. Quatro grupos (n=30) foram obtidos: GC (grupo controle); DE (desafio erosivo); DE.M (desafio erosivo + MI Paste); DE.MP (desafio erosivo + MI Paste Plus). O desafio erosivo foi realizado pela imersão única das amostras em Sprite Zero, durante 30 min. Os grupos DE.M e DE.MP foram submetidos ao tratamento remineralizador com a aplicação de uma camada de aproximadamente 0,5mm por 3 min. Os grupos foram divididos em dois subgrupos: SL (sem laser Nd:YAG) e CL (sistema adesivo + laser Nd:YAG + fotopolimerização). A densidade de energia utilizada foi 174J/cm2, 140 mJ/pulsos, 10 Hz, 1,4W. Todos os espécimes foram restaurados com o sistema adesivo Clearfil SE Bond (Kuraray) e a resina composta Z350XT (3M-ESPE). Após 24h de armazenagem em água deionizada, os espécimes foram cortados em palitos, com secção transversal de 1mm2 de área e em seguida foi realizado o ensaio de microtração. Os dados foram submetidos à ANOVA 2 fatores e foram encontradas diferenças estatísticamente significantes para o fator tratamento (p=0,00). O grupo DE foi o que apresentou menor valor de resistência adesiva após o teste de Tukey. As... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The purpose of this study was to evaluate the influence of CPP-ACP (MI Paste) and CPP-ACP associated to NaF (MI Paste Plus) on microtensile bond strength of dentin softened by a soft drink, irradiated or not with laser Nd:YAG. Sixty human molars had their crowns sectioned from mesial to distal face in order to obtain two specimens. The enamel was flattened until the exposure of 3 mm dentin area and then were embedded in acrylic resin. The samples were randomly divided into four groups (n=30): CG (control group); EC (erosive challenge); EC.M (erosive challenge + MI Paste); EC.MP (erosive challenge + MI Paste Plus). The erosive challenge consisted by a single immersion of the specimens in Sprite Zero, for 30 min. The EC.M and EC.MP were submitted to remineralizing treatment with the application of a 0,5 mm layer, for 3 min. The groups were subdivided into two subgroups: WITH (WL) or WITHOUT (W) Nd:YAG laser application. Laser application was made by the energy density of 174J/cm2, 140 mJ/pulse, 10 Hz, 1.4W, and the sequence was: adhesive system + Nd:YAG laser + photopolimerization. All the samples were restored by the adhesive system Clearfil SE Bond (Kuraray) and the composite Z350XT (3M-ESPE). After 24h storage in deionized water, the samples were cut in sticks, with 1mm2 cross-section area, then was accomplished the microtensile test. The microtensile data were analyzed with two-way ANOVA. Significant statistically differences were found to the treatment factor (p=0.00) and Tukey test showed that the EC group presented lower values to microtensile bond strength. The averages of each group, in ascending order, were: EC.WL (29.22) < EC.W (33.50) < EC.M.W (33.89) < EC.MP.W (34.96) < CG.W (36.40) < EC.MP.WL (36.92) < CG.WL (37.46) < EC.M.WL (37.68). It was concluded that: the... (Complete abstract click electronic access below) / Mestre
830

Reação exotérmica e expansões de presa e térmica de revestimentos frente às técnicas de fundição convencional e rápida /

Marchiori, André Vinícius. January 2007 (has links)
Orientador: Eulália Maria Martins da Silva / Banca: Wirley Gonçalves Assunção / Banca: Paulo Henrique dos Santos / Banca: Osvaldo Luiz Bezzon / Banca: Paulo Martins Ferreira / Resumo: Os protocolos estabelecidos numa técnica de fundição objetivam compensar a contração de solidificação da liga metálica e obter estruturas metálicas fundida com adequada adaptação cervical. A técnica de fundição rápida tem demonstrado ser uma alternativa, mas há dúvidas sobre como os revestimentos se expandem. Este estudo comparou as expansões de presa, térmica e total de três revestimentos odontológicos perante os procedimentos realizados em técnicas de fundição convencional e rápida. Na primeira parte desse estudo, determinaram-se as curvas das expansões resultantes da reação exotérmica de presa (n=5/revestimentoXtécnica), juntamente com as curvas de temperaturas que permitiram determinar o pico da exotermia e o intervalo médio requerido por cada revestimento para atingí-lo e; na segunda parte, aferiu-se a expansão térmica (n=3/revestimento). Para a análise estatística, utilizou-se o ANOVA e o Teste de Tukey (p<0,05). O maior valor médio de temperatura durante a presa foi determinado para o revestimento Micro Fine 1700 (88oC), que não diferiu estatisticamente do Heat Shock (80,3oC) e o menor, para o All Therm (67oC). O Micro Fine 1700 foi o que atingiu seu pico máximo de temperatura mais precocemente (5,8min), seguido pelo Heat Shock (16,4min) e o All Therm (18,8min), sendo todos diferentes entre si (p<0,05). Pôde-se constatar que os três revestimentos avaliados atingiram seus respectivos picos de temperatura num tempo menor ou igual a 20 minutos. Quanto à expansão de presa, para os revestimentos fosfatados foi muito menor no tempo de 20 minutos (tempo de espera para presa na técnica de fundição rápida) em comparação ao que se obteve com 60 minutos; o que não ocorreu, estatisticamente, para o revestimento cerâmico Micro Fine 1700. Só o revestimento cerâmico Micro Fine 1700 apresentou sua expansão de presa estabilizada aos 20 minutos. / Abstract: The protocols established in casting techniques aimed to compensate the solidification contraction of metallic alloy and to get casting metallic structures with accurate marginal fit. The accelerated casting technique has demonstrated to be an alternative, but some doubts regarding investment expansion remains. This study compared the curves of temperatures resultant setting expansion and expansions of setting, thermal and total of three dental investments before the conventional and accelerated casting techniques. In the first part of this study, the curves of the resultant expansion of the setting exothermic reaction (n=5/investment) were determined, together with the curves of temperatures. Based on theses temperatures curves either the maximum exothermic setting reaction temperature, and the mean time interval required for each investment were calculated. In the second part, thermal expansion (n=3/investmentXtechnique) was analyzed. ANOVA and Tukey Test were used as a statistic analysis at 5% level of significance. Micro Fine 1700 investment showed the highest temperature values during the setting (88oC), and did not differ significantly from the Heat Shock (80.3oC) (p>.05). All Therm exhibited lower values (67oC) that differed from the two other investments (p<.05). Micro Fine 1700 reached the maximum exothermic setting reaction temperature first (5.8min), followed by Heat Shock (16.4min) and All Therm (18.8min) (p<.05). It can be evidenced that the three investments had reached their temperature peak until 20 minutes. The setting expansions of the phosphate bonded investments were very lower in the time of 20 minutes (wait time for setting in the accelerated casting technique) in comparison to 60 minutes. However, this difference did not occur to Micro Fine 1700 ceramic investment (p>.05). Analyzing thermal expansion, only Heat Shock showed statistic difference regarding technique factor. / Doutor

Page generated in 0.0547 seconds