• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2304
  • 155
  • 150
  • 150
  • 148
  • 109
  • 35
  • 35
  • 24
  • 17
  • 17
  • 12
  • 7
  • 5
  • 2
  • Tagged with
  • 2362
  • 1247
  • 1039
  • 886
  • 534
  • 523
  • 493
  • 433
  • 425
  • 347
  • 234
  • 192
  • 180
  • 166
  • 163
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
841

Efeito da terapia fotodinâmica sobre a resistência de união e a penetrabilidade dentinária de diferentes protocolos de cimentação de pinos de fibra de vidro /

Ramos, Anna Thereza Peroba Rezende. January 2017 (has links)
Orientador: Marcelo Ferrarezi de Andrade / Resumo: Essa pesquisa avaliou o efeito da Terapia Fotodinâmica (PDT) sobre diferentes protocolos de cimentação de pinos de fibra de vidro com cimentos resinosos convencionais ou autoadesivos, assim como os cimentos ionoméricos, através da resistência de união e penetrabilidade dentinária por meio de ensaio mecânico “push-out”, análise do padrão de fratura e microscopia confocal à laser. Foram utilizados dentes humanos, com raízes padronizadas em 15mm e tratados endodonticamente com o sistema ProTaper (Dentsply, Ballaigues, SW), irrigados com hipoclorito de sódio a 2,5% e obturados pela técnica do cone único com cimento endodôntico contendo resina epóxi (AH Plus; Dentsply DeTrey GmbH, Konstanz, Germany). Após armazenamento em estufa com umidade a 37ºC por 7 dias, foi preparado o espaço e instalado o pino de fibra de vidro com o sistema White Post DC 2 (FGM, Joinville, SC, BR). De forma aleatória, as raízes foram divididas em 6 grupos (n=10) de acordo com o sistema de cimentação e a utilização da PDT. Os grupos que fazem parte da utilização da PDT tiveram seu canal radicular irrigado com soro fisiológico, seco, preenchido com fotossensibilizador (azul de metileno), permaneceu em repouso por 5 minutos e irradiado por uma fibra ótica adaptada em fonte de emissão, então foi removido o corante e seguido o protocolo de cimentação do pino conforme o fabricante recomenda tanto para o tratamento do pino, quanto para o tratamento da dentina radicular e manipulação do cimento. Nessa etapa foi a... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to evaluate the effects of photodynamic therapy (PDT) on the glass-fiber post cementation protocols using conventional or self-adhesive resin cements and a glass ionomer cement (GIC) on the bond strength and dentinal penetrability. The specimens were submitted to the push-out test, failure mode and laser confocal microscopy evaluation. Human canine roots standardized in 15mm were endodontically-treated using ProTaper (Dentsply, Ballaigues, SW) system, irrigated with 2.5% sodium hypochlorite and obturated with single cone technique and epoxi-based sealer (AH Plus; Dentsply DeTrey GmbH, Konstanz, Germany). The specimens were stored under 100% relative humidity, at 37oC for 7 days. Afterwards, the intracanal prosthetic space was prepared and the glass-fiber post (White Post DC 2, FGM, Joinville, SC, BR) was placed. The roots were randomly divided into 6 groups (n = 10) according to the cementation system and PDT use. The groups that used PDT were irrigated with saline, dried, filled with photosensitizer (methylene blue), left untouched for 5min and irradiated using a laser emission source. The pigment was removed, the post cementation protocol was handled according to the manufacturer´s recommendations. Rhodamine B was added in the cementation system to facilitate the evaluation of confocal laser microscopy. The roots were vertically placed inside plastic matrices and filled with polyester resin. After 24h, the set was sectioned in 3 slices according t... (Complete abstract click electronic access below) / Mestre
842

Avaliação da distribuição das tensões em prótese do tipo "All on Four" : estudo pelo método dos elementos finitos tridimensionais /

Amoroso, Andressa Paschoal. January 2013 (has links)
Orientador: Humberto Gennari Filho / Co-orientador: José Vitor Quinelli Mazaro / Banca: Fellippo Ramos Verri / Banca: Ricardo Shibayama / Resumo: Considerando o aumento crescente e contínuo da demanda por tratamento protético reabilitador sobre implantes, aliado ao sucesso comprovado dos implantes osseointegrados, fazem com que a procura de meios possam fortalecer ainda mais este tipo de tratamento, seja abundante, principalmente no que diz respeito à distribuição das forças. Proposta: o objetivo desse trabalho foi analisar a distribuição das tensões geradas em diferentes configurações da prótese tipo protocolo, através do método dos elementos finitos tridimensionais. Materiais e método: para a realização deste estudo foram confeccionados 2 modelos mandibulares com auxílio dos programas de modelagem gráfica SolidWorks 2010 (SolidWorks Corp, Massachusetts, EUA) e Rhinoceros® 3D 4.0 (NURBS Modeling for Windows, EUA). Cada modelo representou uma mandíbula com prótese protocolo sobre implantes de hexágono externo 4,0 x 13,0mm (Master, Conexão Sistemas de Prótese Ltda., São Paulo, Brasil) localizados na região interforaminal, variando a inclinação. Modelo 1: prótese com 4 implantes dispostos perpendicularmente à crista do rebordo e modelo 2: prótese do tipo All on four (implantes distais inclinados em 30º). A representação da prótese foi em resina acrílica e a infra estrutura metálica em NiCr. Os desenhos tridimensionais foram exportados ao programa de elementos finitos FEMAP 11.0 para geração da malha. A carga axial aplicada foi de 300N, bilateral sendo 75N em cada dente, e a oblíqua 150N, unilateral sendo 75N em cada dente, em 1º pré-molares e 1º molares. Resultado: após a análise no programa NEiNastran® 9.2 (Noran Engineering, Inc., EUA), os resultados foram... / Abstract: The increasing and continuous demand for implants prosthetic rehabilitation along with the proven success of dental implants make that search for means which can further strengthen this type of treatment is abundant, especially regarding the distribution of forces. Purpose: The aim of this study was to analyze the stress distribution generated in different configurations of the full-arch implant-supported prostheses, through the three-dimensional finite element method. Material and method: For this study two mandibular models were made using the graphical modeling program SolidWorks 2010 (SolidWorks Corp., Massachusetts, USA) and Rhinoceros® 3D 4.0 (NURBS Modeling for Windows, EUA). Each model represented a jaw with a full-arch implant-supported prosthesis using external hexagon implants with 4.0 x 13.0 mm (Master Connection Implant Systems Ltda., São Paulo, Brazil) located in the interforaminal region, varying the inclination. Model 1: prosthesis with 4 implants arranged perpendicularly to the ridge crest and model 2: All-on-four prosthesis (distal implants tilted at 30 °). The representation of the prosthesis was with acrylic resin and the metallic infrastructure with NiCr. The three-dimensional images were exported to finite element programs FEMAP 11.0 for mesh generation. The axial load applied was 300N, being 75N bilateral in each tooth, and oblique of 150N, being 75N unilateral in each tooth, in 1st premolars and 1st molars. Results: After analysis at the program NEiNastran® 9.2 (Noran Engineering, Inc., EUA), the results were visualized through individualized maps of von Mises stress and main maximum stress on each model. It can be observed in the model with tilted implants, that for both loads the stress concentrations were higher. Conclusion: It was concluded that the All on four prostheses presented highest stress concentrations, especially in the region of the distal implant. / Mestre
843

Avaliação da eficácia de um gel de vedação no selamento da interface pilar/implante e na manutenção da pré-carga dos parafusos de retenção /

Seloto, Camila Berbel. January 2017 (has links)
Orientador: Wirley Gonçalves Assunção / Banca: Paulo Henrique dos Santos / Banca: Juliana Aparecida Delben / Resumo: Esse estudo avaliou a eficácia de um material de vedação na manutenção da pré-carga em parafusos de retenção bem como o desajuste pilar/implante e microinfiltração após ciclagem mecânica. Foram formados seis grupos (n=12) sendo, um grupo teste (T) e um grupo controle (C) para cada tipo de conexão pilar/implante (conexão hexagonal externa (HE) e pilares UCLA; conexão cone Morse (CM) e pilares UCLA; e conexão CM e pilares flexcone (FC)). Nos grupos testes (HET, CMT e FCT) foi aplicado um agente de vedação no parafuso de retenção, enquanto os grupos controle (HEC, CMC e FCC) foram mantidos da forma convencional. Todos os implantes foram embutidos em poliuretano e foram introduzido 0,7μl de Azul de Toluidina (AT) na porção mais profunda de cada um deles. Em seguida, os pilares foram posicionados sobre os implantes e parafusados com o torque recomendado pelo fabricante com auxílio de chave especifica e um torquímetro digital. Formados os corpos-de-prova, estes foram submetidos à ciclagem mecânica (1x106 ciclos), com frequência de 2Hz e carregamento oblíquo de 130N. As avaliações dos desajustes foram realizadas em um estereomicroscópio antes e após a ciclagem mecânica. Para verificar a capacidade de vedação do agente após a ciclagem mecânica foi desenvolvida uma curva padrão, na qual determinou-se a diluição de azul de toluidina (AT). Em seguida, os dados foram analisados em espectrofotômetro para a formação da curva padrão. Na sequência, os corpos-de-prova foram colocadas individu... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated the effectiveness of a sealing material in preload maintaining of retaining screws and the misfit on implant / abutment interface after mechanical cycling. It was formed six groups (n=12), being one test group (T) and other control group (C) for each type of abutment / implant connection (external hexagonal connection (EH) and UCLA abutments, Morse taper (MT) and UCLA abutments, and CM connection and flexcone (CF) abutments). In the test groups (EHT, MTT and CFT) a sealing agent was applied on the retention screw, whereas the control groups (EHC, MTC and CFC) were maintained in the conventional manner. All implants were embedded in polyurethane and into the deeper portion of each implant it was introduced 0.7 μl of Toluidine Blue (TB). After that, the abutments were screwed to the implants with the torque values recommended by the manufacturer with the aid of a specific wrench and a digital torque wrench. The specimens formed were submitted to mechanical cycling (1x106 cycles) with frequency of 2Hz and oblique loading of 130 N. The misfit evaluation were performed at a stereomicroscope before and after a mechanical cycling. In order to verify the gel sealing ability after the mechanical cycling a standard curve was performed to determine the blue toluidine (TB) dilution. Then the data obtained were analyzed in a spectrophotometer for a standard curve formation. Afterwards, the specimens were placed in vials containing 400μl of distilled water. The spectrophotometric analysis was performed at 8 different times (1, 3, 6, 24, 48, 72, 96 and 144 hours). Finally, measurements of final destorque values (post-cycling) were performed. The misfit data, destorque and dye release (sealing ability) were obtained and submitted to normality statistical tests and then analyzed by ANOVA and Tukey tests (α = 0.05). The ANOVA... / Mestre
844

Avaliação das microdeformações ao redor de implantes, na utilização de pilares protéticos retos e angulados 17° e 30°, sob a influência de aplicação de cargas /

Rodrigues, Vinícius Anéas. January 2017 (has links)
Orientador: Renato Sussumu Nishioka / Banca: Sergio Eduardo de Paiva Gonçalves / Banca: Alfredo Mikail Melo Mesquita / Banca: Lucilene Hernandes Ricardo / Banca: Luis Gustavo Oliveira de Vasconcellos / Resumo: O objetivo deste estudo in vitro foi analisar a distribuição das microdeformações geradas ao redor de implantes de hexágono externo, sob a influência da utilização de intermediários do tipo mini pilares cônicos retos e angulados 17° e 30°, sob cargas axiais e não axiais, por meio da análise de elementos finitos e extensometria. Os modelos tridimensionais foram criados simulando três blocos de poliuretano, os quais receberam três implantes cada, um grupo perpendicular e outros dois com fixações inclinadas em 17° e 30°. Para o estudo também foram modelados os intermediários do tipo mini pilar cônico reto e angulados e uma supraestrutura metálica padronizada para ambos os grupos, os materiais foram considerados homogêneos, isotrópicos e lineares. Após a confecção, as geometrias foram exportadas em malhas para o software de análises (ANSYS 15.0, ANSYS Inc., Houston, USA), um carregamento axial de 30 kgf foi aplicado e os valores de tensão e as microdeformações foram analisados. Para análise in vitro, foram confeccionados blocos idênticos aos desenhados anteriormente. Foram colados sete extensômetros na superfície dos blocos, quatro tangenciando cada um dos implantes e três na transversal dos implantes. Coifas plásticas foram adaptadas a um enceramento padronizado e depois fundidas. A supraestrutura metálica foi parafusada com torque de 10 N.cm. Para aplicação de cargas foi utilizado um dispositivo de aplicação de cargas (DAC) com uma carga de 30 kgf. durante 10 segundos. Os dados... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The objective of this in vitro study was to analyze microstrains distribuition generated around external hexagon implants, under the influence of intermediary prosthetic componentes as straight, 17° and 30° angled miniconical abutments, under axial and non-axial loads, by finite elements and strain-gauge analysis. The three-dimensional models were created simulating three polyurethane blocks, being installed three implants each, one perpendicular group and another two with inclined fixations at 17° and 30°. For the study were also created straight and angled miniconical abutments and a standardized metallic superstructure for both groups. The materials were considered symmetrical, isotropic and solid. After the preparation, the geometries were exported in mesh to the analysis software (ANSYS 15.0, ANSYS Inc., Houston, USA). An axial load of 30 kgf was applied and the values of main maximum stress and microstrains were analyzed. For in vitro analysis, blocks identical to those created previously were made, seven strain-gauges were placed on the surface of the block, four tangential to each of the implants and three transverse to the implants. Plastic copings were adapted to a wax pattern and then cast. The metallic superstructure was screwed with a torque of 10 N.cm. For load application, a load application device (DAC) with a load of 30 kgf was used, for 10 seconds. Data were submitted to ANOVA and Tukey tests (p <0.05). Statistical difference was observed for "Implant angulation" factors (P = 0.000) and "Load application point" factor (P = 0.000). The data obtained by the finite element analysis were presented as: qualitative results of stress that were analyzed following the color scheme of the scale and results of deformation values, presented in graphs, where it observed a higher concentration of tension in the inclined implants in 30° at the ... (Resumo completo, clicar acesso eletrônico abaixo) / Doutor
845

Análise in vivo da modulação óssea em implantes de titânio com superfície em nanoescala /

Carvalho, Lais Morandini. January 2017 (has links)
Orientador: Luana Marotta Reis de Vasconcellos / Coorientador: Gustavo Mendonça / Banca: Daniela Baccelli Silveira Mendonça / Banca: Elisa Mattias Sartori / Banca: Yasmin Rodarte Carvalho / Banca: Renata Falchete do Prado / Resumo: Nas últimas décadas houve um aumento considerável na utilização dos implantes metálicos para aplicações na área da ortopedia e odontologia, por isso as pesquisas têm como foco estudar os mecanismos biológicos de interação osso-implante. A nanotopografia de superfície de implantes osseointegráveis apresenta efeito direto sobre a resposta biológica óssea. No entanto a maneira como afeta a osseointegração in vivo ainda não está totalmente elucidada. O objetivo neste estudo foi comparar in vivo a influência da superfície em nanoescala (nano) confeccionada em implantes de titânio comercialmente puro (Ticp), comparado-a a superfície lisa (controle) em modelo experimental de camundongos osterix-mcherry (Osx-mcherry), os quais expressam proteína fluorescente concomitante com a expressão do gene osterix (Osx). Os animais receberam implantes de superfície lisa no fêmur direito e com nanoescala no fêmur esquerdo. Após diferentes períodos de eutanásia baseados na metodologia empregada foram realizados nas peças e nas células os seguintes testes biológicos: microscopia eletrônica de varredura (MEV) para avaliação da adesão celular e da superfície do implante; histologia e nanotomografia (nanoCT) para observação e quantificação de osso neoformado na interface osso/implante; citometria de fluxo para quantificação de células marcadas pelo gene osterix; PCR em tempo real (qPCR) para avaliação da expressão gênica; coloração fosfatase ácida resistente ao tartarato (TRAP) para contagem de osteoc... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: In the last decades there has been a considerable increase in the use of metal implants for applications in the area of orthopedics and dentistry, so the researches are focused on studying the biological mechanisms of boneimplant interaction. Surface nanotopography of osseointegrated implants has a direct effect on the biological response of bone. However the way it affects osseointegration in vivo is not yet fully elucidated. The aim of this study was to compare the in vivo influence of the nanoscale surface (nano) made on implants of commercially pure titanium (Ticp) with the smooth surface (control), using an experimental model of osterix-mcherry mice (Osxmcherry), which express fluorescent protein concomitant with osterix gene expression (Osx). The animals received implants with smooth surface in the right femur and nanoscale in the left femur. After different periods of euthanasia based on the methodology used, biological tests were performed in the femur and cells: scanning electron microscopy (SEM) for evaluation of cell adhesion and implant surface; histology and nanotomography (NanoCT) for observation and quantification of neoformed bone at implant interface; flow cytometry for quantification of cells marked by the osterix gene; Realtime PCR (qRT-PCR) for gene expression evaluation; tartrate resistant acid phosphatase staining (TRAP) for osteoclast counts. Our results showed that most genes studied were overexpressed in the nanoscale surface and some of which presented statistical differences(t Test, p <0.05), such as: Osx (osterix), Alp (alkaline phosphatase), Prx1 (related paired homeobox), Dmp1 (Dolicol-phosphatase mannosyltransferase subunit 1), Bsp (bone sialoprotein) and Ocn (osteocalcin). The two-way ANOVA statistical test followed by the Tukey test when necessary were used for the other experiments and the level ...(Resumo completo, clicar acesso eletrônico abaixo) / Doutor
846

Avulsão dentária : efeito da informação na mudança de comportamento em diferentes grupos profissionais

Frujeri, Maria de Lourdes Vieira January 2006 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Ciências da Saúde, 2006. / Submitted by Thaíza da Silva Santos (thaiza28@hotmail.com) on 2009-09-25T02:14:17Z No. of bitstreams: 1 2006_Maria de Lourdes Vieira Frujeri.pdf: 771107 bytes, checksum: aaa00a64bff42357245a3fa97079e143 (MD5) / Approved for entry into archive by Gomes Neide(nagomes2005@gmail.com) on 2010-07-14T16:54:49Z (GMT) No. of bitstreams: 1 2006_Maria de Lourdes Vieira Frujeri.pdf: 771107 bytes, checksum: aaa00a64bff42357245a3fa97079e143 (MD5) / Made available in DSpace on 2010-07-14T16:54:49Z (GMT). No. of bitstreams: 1 2006_Maria de Lourdes Vieira Frujeri.pdf: 771107 bytes, checksum: aaa00a64bff42357245a3fa97079e143 (MD5) Previous issue date: 2006 / A avulsão dentária é muito comum durante as práticas esportivas, no ambiente escolar e no lazer. Professores, técnicos esportivos e pessoas leigas são freqüentemente requisitados para prestar os primeiros socorros. As primeiras ações são cruciais para o prognóstico do dente avulsionado. Com o objetivo de avaliar a influência do trabalho educativo nos diferentes grupos de profissionais a respeito do conhecimento, prevenção e manuseio urgencial do dente avulsionado foram selecionados cinco grupos profissionais (professores de ensino fundamental, profissionais de educação física, bancários, cirurgiões-dentistas e médicos), inscritos nas Entidades de Classe na cidade de Brasília, região do DF, Brasil. A avaliação foi feita por meio de dois questionários aplicados aos profissionais, sendo um aplicado antes da palestra informativa, com o intuito de averiguar as noções do profissional sobre o assunto, e o outro dois meses após a mesma, para a verificação do ganho de conhecimento pelos profissionais e, naturalmente, avaliar a influência das informações transmitidas. Os resultados dos 479 questionários retornados foram tabulados, apurados e analisados estatisticamente por meio dos Softwares SAS (SAS Institute, Cary NC) e SPSS (Statistical Package for the Social Sciences - SPSS Inc, Chicago). Para avaliar a diferença entre as respostas antes e depois da palestra educativa foi utilizado o teste de Wilcoxon. Verificou-se mudança estatisticamente significante nas respostas dos profissionais após a transmissão das informações em todos os grupos (p < 0,0001). No primeiro questionário, foi observada falta de conhecimento em relação ao assunto e às ações adequadas a serem realizadas diante do traumatismo. Entretanto foi observada substancial melhoria em suas respostas após as informações recebidas na palestra educativa, mostrando deste modo, a importância da informação no conhecimento sobre o pronto atendimento desta injúria traumática. Concluiu-se que a educação é extremamente importante para favorecer o conhecimento da prevenção e do manuseio urgencial de um dente avulsionado e conseqüentemente pode melhorar o prognóstico da avulsão dentária. ______________________________________________________________________________________ ABSTRACT / Dental avulsion is very common during sports practice at school environments or during leisure time. Professors, coaches and the public in general frequently asked to provide first aid in such urgencies. First aids are crucial for the prognosis of the avulsed tooth. With the objective to evaluate the influence of educational work among different group of professionals regarding knowledge, prevention, and urgency tooth management, there were selected five professional groups (first grade teachers, physical education teachers, bank clerks, surgeon-dentists and doctors), who belong to Unions in Brasília, in the Federal District region, Brazil. The evaluation was made by means of 2 questionnaires. One was applied before de lecture, in order to evaluate the professionals’ knowledge on the subject; and the other was applied 2 months after the lecture, to verify the professionals’ gain of knowledge and, naturally, to evaluate the influence of the information delivered. The results on the 479 questionnaires answered were formatted, assessed and analyzed statistically by the Softwares SAS (Institute Cary, NC) and SPSS (Statistical Package for the Social Sciences – SPSS Inc, Chicago). In addition, to evaluate the difference between the responses given on the questionnaires applied before and after the lecture, it was utilized the Wilcoxon test. In all groups of professionals it was observed a statistically significant change in the responses given by participants after the information delivered (p < 0,0001). In the first questionnaire, it was observed a lack of knowledge on the subject and on the adequate actions to be taken in a dental trauma. On the other hand, it was verified a substantial improvement on the responses after receiving information on the lecture. This way, it shows the importance of knowledge on the subject for prompt care of this traumatic injury. It was concluded that Education is extremely important to favor the knowledge of prevention, emergency handling of an avulsed tooth and, consequently, it may better dental avulsion prognosis.
847

Comportamento eletroquímico do Ti2, Ti4, Ti4hard e Ti6Al4V em função de diferentes aplicações tópicas de flúor /

Zanna, Carolina Ferrairo Danieletto. January 2017 (has links)
Orientador: Wirley Gonçalves Assunção / Banca: Leonardo Perez Faverani / Banca: Valentim Adelino Ricardo Barão / Resumo: Pacientes com reabilitações implantossuportadas parciais podem apresentar condições clínicas que necessitem de fluorterapia. Sabe-se que o fluoreto possui uma ação corrosiva em alguns metais, portanto o objetivo deste estudo foi investigar o comportamento eletroquímico e as alterações de superfície, dos titânios Grau 2 (comercialmente puro Grau 2 - Ti2), Grau 4 - Ti4, Grau 4 hard - Ti4h, e Grau 5 - Ti5, comumente utilizados para confecção de implantes e componentes protéticos, frente a exposição de aplicações tópicas de flúor em bochecho e gel. Espécimes cilíndricos (3mm de altura e 8mm de diâmetro) (n=20) foram confeccionados a partir de cada titânio e submetidos a metalografia. A amostra foi dividida em quatro grupos: Baseline (n=20), Controle - C (n=20), Bochecho - B (n=20) e Gel - G (n=20). No Baseline os espécimes foram caracterizados através de microdureza de Vickers, rugosidade superficial - Ra, Microscopia Eletrônica de Varredura - MEV e Espectroscopia de Energia Dispersiva - EED. No Bochecho, os espécimes ficaram imersos em saliva artificial pura (SA) acrescida de NaF (225ppm F-) e mantidos em constante agitação durante 30horas e 41minutos, simulando bochechos diários; no Gel, os espécimes foram imersos em SA acrescida de NaF (12.300ppm F-), mantidos por 1 minuto, na sequência, transferidos para solução de SA pura, na qual permaneceram por 30 minutos (processo repetido 6 vezes), simulando aplicações de flúor fosfato acidulado 1,23% e no Controle, os espécimes não ent... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Patients with partial implant-supported rehabilitations may present clinical conditions that require fluorotherapy. It is known that fluoride has a corrosive action on some metals, so the objective of this study was to investigate the electrochemical behavior and surface changes of grade 2 titanium (commercially pure Grade 2 - Ti2), Grade 4 - Ti4, Grade 4 Hard - Ti4h, and Grade 5 - Ti5, commonly used for the preparation of implants and prosthetic components, against the exposure of topical applications of fluoride in mouthwash and gel. Cylindrical specimens (3mm high and 8mm diameter) (n = 20) were made from each titanium and subjected to metallography. The sample was divided into four groups: Baseline (n = 20), Control - C (n = 20), Bochecho - B (n = 20) and Gel - G (n = 20). In the Baseline the specimens were characterized by Vickers microhardness, surface roughness - Ra, Scanning Electron Microscopy - SEM and Dispersive Energy Spectroscopy - EED. In Bochecho, the specimens were immersed in pure artificial saliva (SA) plus NaF (225ppm F-) and kept in constant agitation for 30hours and 41minutes, simulating daily mouthwashes; In the Gel, the specimens were immersed in SA plus NaF (12,300ppm F-), maintained for 1 minute, then transferred to pure SA solution, in which they remained for 30 minutes (6 times repeated procedure), simulating Fluorinated phosphate 1.23% and in Control, the specimens did not come into contact with fluoride solutions. The groups C, B and G were submit... (Complete abstract click electronic access below) / Mestre
848

Influência da oclusão traumática no processo de reparo do periodonto em dentes submetidos a luxação extrusiva /

Debortoli, Caio Vinícius Lourenço. January 2018 (has links)
Orientador: Celso Koogi Sonoda / Coorientadora: Daniela Atili Brandini de Weert / Banca: Ligia Antunes Pereira Pinelli / Banca: Francisley Ávila Souza / Resumo: O tratamento luxação extrusiva visa o reparo das estruturas de suporte do periodonto com o dente em posição original, contudo pode ser prejudicado por alguns fatores como a oclusão traumática. Este estudo avaliou a influência da oclusão traumática no processo de reparo dos tecidos de suporte periodontais de dentes que sofreram luxação extrusiva. Sessenta ratos Winstar foram divididos em três grupos: Grupo Controle (n=20), Grupo Luxação Extrusiva (n=20) e Grupo Luxação Extrusiva e Oclusão Traumática (n=20), nos períodos experimentais de 7 e 30 dias. O dente de estudo foi o primeiro molar inferior direito. A luxação extrusiva foi simulada pela indução de forças no sentido axial até o seu deslocamento e reposição do dente por pressão digital. A oclusão traumática foi induzida por restauração de resina composta e fio metálico na superfície oclusal, criando uma plataforma plana.Cortes histológicos longitudinais foram corados com hematoxilina e eosina, Picrosirius red e técnica imunoistoquímica para detecção da TRAcP. Foi avaliada a reabsorção óssea e dentária, área de fibras colágenas, matriz extracelular não fibrilar e vasos sanguíneos, número de perfil nuclear e células TRAcP, organização do ligamento periodontal, extensão e intensidade do processo inflamatório. O teste de Kruskal-Wallis e post hoc de Dunn foram utilizados para a comparação entre os grupos (α=0,05). Dentre as diferenças significativas observou-se: aos 7 dias um aumento de células TRAcP e uma diminuição da área ó... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The extrusive luxation treatment aims to repair the structures of the periodontium with the tooth in original position, however it can be impaired by some factors such as traumatic occlusion. This study aims to evaluate the influence of traumatic occlusion on the repairing process of the periodontal tissues of the tooth submitted to extruded luxation. Sixty Winstar rats was divided into three groups: Control group (n=20), Extrusive luxation group (n=20) and Extrusive luxation and Traumatic Occlusion group(=20), in the experimental periods of 7 and 30 days. The experimental tooth was the first lower right molar. The extrusive luxation was simulated by the induction of forces in the axial direction until its displacement and replacement of the tooth by digital pressure. Traumatic occlusion was induced by restoration of composite resin and metallic wire on the occlusal surface, creating a flat platform. Longitudinal histological sections were stained with hematoxylin and eosin, Picrosirius red and immunohistochemical technique for the detection of TRAcP. Bone and dental resorption, area of collagen fibers, extracellular non-fibrillar matrix and blood vessels, number of nuclear profile and TRAcP cells, periodontal ligament organization, extent and intensity of the inflammatory process were evaluated. The Kruskal-Wallis and post hoc Dunn tests were used to compare the groups (α = 0.05). Among the significant differences were observed at 7 days an increase of TRAcP cells and a decr... (Complete abstract click electronic access below) / Mestre
849

Avaliação da fotobiomodulação Laser (λ 780nm) no reparo de reimplantes dentários em ratos

Carvalho, Fabíola Bastos de 12 September 2013 (has links)
Submitted by Hiolanda Rêgo (hiolandar@gmail.com) on 2013-11-25T20:53:18Z No. of bitstreams: 1 Tese_ODONTO_Fabíola Bastos de Carvalho.pdf: 2651347 bytes, checksum: 380f5a3bef49aa07e2f8f877b68e9e3f (MD5) / Approved for entry into archive by Rodrigo Meirelles (rodrigomei@ufba.br) on 2013-11-26T14:55:06Z (GMT) No. of bitstreams: 1 Tese_ODONTO_Fabíola Bastos de Carvalho.pdf: 2651347 bytes, checksum: 380f5a3bef49aa07e2f8f877b68e9e3f (MD5) / Made available in DSpace on 2013-11-26T14:55:06Z (GMT). No. of bitstreams: 1 Tese_ODONTO_Fabíola Bastos de Carvalho.pdf: 2651347 bytes, checksum: 380f5a3bef49aa07e2f8f877b68e9e3f (MD5) / Capes / O reimplante dentário é o tratamento de escolha nos casos de traumatismos com avulsão. Entretanto, seu sucesso é limitado, pois grande parte dos dentes é perdida devido à reabsorção radicular progressiva. O prognóstico depende dos procedimentos realizados antes e após o reimplante. Dessa forma, o objetivo desse estudo foi avaliar por meio de análise histológica em microscopia de luz, o efeito da fotobiomodulação laser, antes e após reimplante dentário, no reparo tecidual em incisivos de ratos. Para tanto foram utilizados 60 ratos Wistar albinus, que tiveram o incisivo superior direito extraído, e em seguida divididos em 4 grupos (G1 – extração, permanência do dente em meio seco por 40 minutos e reimplante, G2 – extração, conservação do dente em leite por 40 minutos e reimplante, G3 - extração, conservação do dente em leite por 40 minutos, irradiação laser AsGaAl na superfície dentária e na entrada do alvéolo (λ= 780nm; P= 70mW; CW; 21J/cm2 por tratamento) seguida de reimplante, G4 - extração, conservação do dente em leite por 40 minutos, irradiação laser AsGaAl na superfície dentária e na entrada do alvéolo nos mesmos parâmetros do G3, seguido de reimplante. No G4 após reimplante a mucosa vestibular e palatina correspondente a raiz do dente reimplantado recebeu irradiação laser (λ= 780nm; P= 70mW; CW; 8,4J/cm2 por sessão a cada 48 horas por 15 dias). A morte dos animais ocorreu após 15, 30 e 60 dias do reimplante. A hemimaxila direita foi removida, fixada em solução de formalina a 10% e processada histologicamente. Foram obtidos cortes longitudinais de 5m, os quais foram corados pela técnica da Hematoxilina e Eosina e avaliados quanto a presença de reabsorções radiculares externas, anquilose, osteoclastos e inflamação. Aos 15 dias o G4 demonstrou inflamação crônica mais intensa, com presença de células clásticas e reabsorção radicular inflamatória moderada, com diferenças estatísticas (p=0,04) quando comparado ao G3, no qual foi observada a ausência desses parâmetros. Aos 30 dias nos Grupos 1, 2 e 4 foi observada inflamação crônica discreta a moderada e reabsorção radicular severa. O G3 permaneceu com ausência de inflamação e reabsorção radicular inflamatória nos períodos de 30 e 60 dias. Concluiu-se que a fotobiomodulação laser na superfície dentária e na entrada do alvéolo antes do reimplante, favoreceu o processo de reparo de reimplante dentário em ratos, quando comparado aos demais grupos.
850

Avaliação das diferenças de resistencia a remoção de coroas fundidas em ligas de cobre-aluminio cimentadas a fundações de amalgama retidas com &quot;amalgapin&quot;

Andrade, Cezar Alves de January 1987 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciencias da Saude / Made available in DSpace on 2012-10-16T01:02:06Z (GMT). No. of bitstreams: 0Bitstream added on 2016-01-08T15:40:16Z : No. of bitstreams: 1 98177.pdf: 3869763 bytes, checksum: 85f60c028a67589e4a18b026a095ada2 (MD5) / Este resumo avalia as diferenças de resistência à remoção de coroas da liga de cobre/alumínio cimentadas a fundações de amálgama, retidas com "amalgapin". Foram formados quatro grupos (A, B, C e D), com dez corpos de prova para cada grupo. Os corpos de prova utilizados foram molares de tamanho parecidos. Os grupos A e B sofreram desgastes parciais em todas as cúspides; no grupo C foram mantidas duas cúspides sem nenhum desgaste, e no grupo D deixou-se, somente, uma cúspide intacta. Os dentes foram preparados para receberem restaurações de amálgama, retidas com dois, três, quatro e seis pinos de amálgama, "amalgapin". Após isto, submeteu-se todos os corpos de prova a preparo para receberem coroas metálicas totais da liga cobre/alumínio. Os preparos tinham a altura cérvico-oclusal de 4 mm. Todos foram preparados com chanfrado até aprofundarem 2 mm na direção cervical em estrutura dentária. Os outros 2 mm eram confeccionados em amálgama (grupo A e B) e em amálgama/dentina (grupos C e D). Os quarentas corpos de prova foram cimentados, receberam coroas totais metálicas fundidas da liga cobre/alumínio e foram submetidos à força de tração para verificação da resistência direta das coroas e indireta das fundações retidas com pinos de amálgama "amalgapin". Através dos resultados obtidos nesta pesquisa foi possível concluir que: não houve diferença estatisticamenre significante com relação à influência do número de "amalgapin" na resistência à remoção de coroas totais metálicas cimentadas em fundações com coroas recontruídas com amálgama.

Page generated in 0.1122 seconds