• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2304
  • 155
  • 150
  • 150
  • 148
  • 109
  • 35
  • 35
  • 24
  • 17
  • 17
  • 12
  • 7
  • 5
  • 2
  • Tagged with
  • 2362
  • 1247
  • 1039
  • 886
  • 534
  • 523
  • 493
  • 433
  • 425
  • 347
  • 234
  • 192
  • 180
  • 166
  • 163
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
851

Acurácia dimensional e visibilidade do canal mandibular na tomografia computadorizada de feixe cônico

Waltrick, Karen Borges 25 October 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2010 / Made available in DSpace on 2012-10-25T09:24:13Z (GMT). No. of bitstreams: 1 285114.pdf: 1107603 bytes, checksum: 98af1c441fcb1bf6610b33c83996e213 (MD5) / O presente estudo in vitro teve como objetivos verificar a acurácia de mensurações lineares para o planejamento de implantes nas imagens de tomografia computadorizada de feixe cônico (TCFC) obtidas com diferentes tamanhos de voxel, e analisar a visibilidade do canal mandibular nestas imagens. Doze hemimandíbulas humanas secas foram escaneadas com três tamanhos de voxels (0,2; 0,3 e 0,4mm) gerando 108 imagens transversais de TCFC, nas quais dois observadores realizaram 648 medidas e avaliaram a visualização do canal mandibular. A média geral dos erros de medição entre as medidas nas imagens e as medidas diretas (feitas por meio de paquímetro digital) foi de 0,23mm (DP± 0,20). As medidas de TCFC subestimaram as medidas diretas em 390 casos (60,2%). Todos os erros de medição encontrados foram inferiores a 1mm. De modo geral, não houve diferença estatisticamente significativa entre os erros de medição nos diferentes tamanhos de voxel e entre os observadores. Entre os dois observadores houve diferença estatisticamente significativa (p<0,05) apenas na medida em largura, nos dois sítios localizados mais posteriormente. Entre os diferentes tamanhos de voxel, houve diferença estatisticamente significativa (p<0,05) apenas para um dos observadores, em uma medida em altura, no sítio localizado na região do 1º molar. Foi possível visualizar o canal mandibular em todas as 108 imagens avaliadas. As imagens transversais de TCFC mostram-se aceitáveis para mensurações lineares na região posterior da mandíbula e com um alto desempenho na visualização do canal mandibular nos tamanhos de voxel 0,2; 0,3 e 0,4mm. Os resultados deste estudo apontam a opção por um tamanho de voxel de 0,3mm como sendo a mais propícia, pois conjuga boa qualidade da imagem e baixa dose de radiação. / The aims of the present in vitro study was to verify the accuracy of linear measurements for implant planning performed in cone beam computed tomography (CBTC) images obtained with different voxel sizes, and to analyze the visibility of the mandibular canal in these images. Twelve dry human hemimandible were scanned with three voxel sizes (0.2, 0.3 and 0.4 mm), generating 108 cross-sectional images in which two observers made 648 measurements and evaluated the visibility of the mandibular canal. The mean overall measurement errors between the measurements in the images and the direct measurements was 0.23 mm (SD ± 0.20). CBTC measurements underestimated the direct measurements in 390 cases (60.2%). All measurement errors were smaller than 1mm. Overall, no statistically significant difference between the measurement errors in different voxel sizes and among observers. Between the two observers, there was one statistically significant difference (p <0.05) in the width of two sites located more posteriorly in the mandible. Among the different voxel sizes, there was a statistically significant difference (p <0.05) for an observer at a height measured at the site located in the region of the first molar. It was possible to visualize the mandibular canal in all the 108 files evaluated. The cross-sectional images of CBCT are acceptable for linear measurements in the posterior mandible and with a high performance visualization of the mandibular canal in voxel sizes of 0.2, 0.3, and 0.4mm. The results show the option for a voxel size of 0.3 mm as the most suitable, because it combines good image quality and low radiation dose.
852

Osteopromoção através do uso combinado de parafusos de osso bovino e membranas reforçadas com titânio

Bianchini, Marco Aurélio January 2006 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia. / Made available in DSpace on 2012-10-22T16:17:23Z (GMT). No. of bitstreams: 1 227228.pdf: 1062066 bytes, checksum: 0c7c90d03e3ae12cc37a210d9b41fd92 (MD5) / O presente trabalho avaliou o papel dos parafusos de osso bovino associados a membranas reforçadas com titânio na osteopromoção. Dezoito cães beagle receberam oito parafusos instalados na tíbia direita, sendo que 4 ficaram isolados e 4 foram recobertos por uma membrana reforçada com titânio. Os cães foram avaliados clinica e histologicamente após 2, 4 e 6 meses. A análise histológica demonstrou haver a presença de novo osso nas áreas enxertadas. As observações clínicas detectaram um ganho ósseo vertical médio de 5,15 mm. Os resultados sugerem que os parafusos de osso cortical bovino podem ser utilizados em associação com as membranas reforçadas com titânio melhorando a osteopromoção.
853

Análise pelo método dos elementos finitos de um dispositivo para estabilização de implantes em áreas de pneumatização do seio maxilar

Siqueira, Aline Franco January 2006 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia. / Made available in DSpace on 2012-10-22T21:48:30Z (GMT). No. of bitstreams: 1 233953.pdf: 926085 bytes, checksum: 982f9d5ec7bea19f1093b0dbe9ca4f03 (MD5) / A instalação de implantes na região posterior da maxila é um desafio frente aos padrões de reabsorção pós-exodontia, pneumatização do seio maxilar e também pela qualidade do tecido ósseo remanescente. Este estudo analisou a distribuição de tensões, através do método dos elementos finitos, no tecido ósseo adjacente a um implante instalado em uma maxila posterior edêntula submetida a diferentes tratamentos. A maior concentração de tensões foi no osso cortical tanto da crista óssea quanto do assoalho do seio maxilar. O dispositivo de retenção proposto apresentou uma melhor distribuição de tensões quando comparado a ausência de tratamento, porém, as situações com enxerto ósseo mostraram-se mais favoráveis que as demais. In the posterior maxilla, implant placement is frequently complicated by unfavorable postextraction resorptive patterns, pneumatization of the maxillary sinus and the often poor quality of the remaining alveolar bone. Many techniques have been developed and tested to reduce the size and alter the anatomy of the sinus to augment the quantity of bone available for an adequate number of prosthetically well-placed implants of a satisfactory length. This in vitro study investigated the stress distribution in the bone surrounding an implant placed in a posterior edentulous maxilla. Material and Methods: 4 3D-Finite Element models of a maxillary posterior section were used to simulate different clinical scenarios: 1-no treatment, 2- a retention device, 3-bone grafts and 4-sufficient residual bone for implant placement. Axial and oblique loads of 300 N were considered and the stresses developed in the supporting structures were analyzed. Results: The von Mises stress distribution showed a high stress concentration in both cortical bone (maxillary bottom and crestal bone). The stress distribution in proposed device was better than the model with the absence of treatment and the bone grafts showed a more suitable stresses distribution than the others models. Conclusion: These findings suggest that this device could be a new clinical approach for the posterior atrophic edentulous maxilla if the in vivo studies validated the present results.
854

Teste mecânico de compósitos indiretos aplicados diretamente sobre abutments implanto-suportados

Andriani Júnior, Wilson January 2007 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia. / Made available in DSpace on 2012-10-23T01:48:19Z (GMT). No. of bitstreams: 1 248356.pdf: 800328 bytes, checksum: 2cbd10e89943f6262ee950f18f7b0fee (MD5) / O objetivo deste estudo foi avaliar a resistência a fratura de 3 compósitos indiretos aplicados diretamente sobre abutments de Ti-6Al-4V, implanto suportados. Quarenta e oito abutments coroas integrados foram alocados aleatoriamente em 3 grupos. Os abutments foram submetidos à abrasão (sandblasting) e em seguida foram deixados em recipiente contendo etanol, por 5min no ultra-som. Depois de secos em condições ambientais, um molde personalizado foi utilizado para confecção de coroas idênticas (n=16 por grupo) deTescera (Bisco, Schaumburg,USA), Ceramage (Shofu, Kyoto ,Japan), e Diamond Crown (DRM Research Laboratories,Braford, CT,USA). As coroas foram fabricadas de acordo com as instruções do fabricante. As coroas foram carregadas mecanicamente até a fratura através de um identador posicionado na ponta de uma das cúspides com uma velocidade avaliada em 1mm/min. Em seguida a análise das fraturas foi realizada através de estereomicroscopia e microscópico eletrônico de varredura. ANOVA, com nível de significância 95% e Tukey`s post-hoc para comparações múltiplas foram utilizados para análise estatística. Os resultados de resistência à fratura com este tipo de carga (single-load) foram: Tescera (1130 ± 105Na), Ceramage (1099 ± 105Na), e Diamond Crown(1155 ± 105Na) (p> 0,85). A análise pela estereomicroscopia mostrou dois modos distintos de fratura das cúspides, com ou sem exposição do abutment. Fraturas sem exposição do abutment ocorreram em aproximadamente 80% das amostras de Tescera, 60% das amostras de Ceramage e 40% das amostras de Diamond. Análise das fraturas através de microscópio eletrônico de varredura (MEV) mostrou múltiplas propagações das trincas em direção a região cervical da coroa, abaixo da região de deformação plástica onde o identador contactava. Uma redução na quantidade de vazios (bolhas) foi observada na microestrutura do Tescera quando comparado com os outros materiais compósitos. Todos os compósitos apresentaram alta resistência à fratura com os valores excedendo a função oclusal normal. The purpose of this study was to test the strength to failure of three indirect composite materials directly applied onto Ti-6Al-4V implant abutments. 48 locking taper abutments were randomly allocated to three groups and were cleaned in ethanol in an ultrasonic bath for 5 minutes. After drying under ambient conditions, the abutments were grit-blasted and a custom 4-cusp molar crown mold was utilized to produce identical crowns (n=16 per group) of Tescera (Bisco, Schaumburg, USA), Ceramage (Shofu, Kyoto, Japan), and Diamond Crown (DRM Research Laboratories, Bran ford, CT,USA). The crowns were produced according to the manufacturer's instructions. The crowns were loaded to failure by an indenter placed at one of the cusp tips at a 1mm/min rate. Subsequently, fracture analysis was performed by means of stereomicroscopy and scanning electron microscopy. One-way ANOVA at 95% significance level and Tukey's post-hoc multiple comparisons were utilized for statistical analysis. The single load to failure results were: Tescera (1130 ± 105Na), Ceramage (1099 ± 105Na), and Diamond Crown (1155 ± 105Na) (p > 0.85). Stereomicroscopy analysis showed two distinct failure modes, where the loaded cusp failed either with or without abutment exposure. Fractures without abutment exposure comprised ~80% for Tescera, ~60% for Ceramage, and ~40% for Diamond crown samples. SEM analysis of the fractures showed multiple crack propagation towards the cervical region of the crown below a region of plastic deformation at the indenter contact region. A reduced amount of micro structural voids were observed for Tescera compared to the other composite materials. All composite materials presented high strength to failure values which exceeded normal occlusion function.
855

Influência do uso de pino fibro/resinoso intra-radicular na resistência à fratura de dentes anteriores

Melo, Fernando Vilain de January 2007 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de de Pós-Graduação em Odontologia. / Made available in DSpace on 2012-10-23T12:33:05Z (GMT). No. of bitstreams: 1 242121.pdf: 4720698 bytes, checksum: 4901e54bc769c9d7586cd0b7de8f81ef (MD5) / Este estudo teve como objetivo avaliar a resistência à fratura de dentes anteriores endodonticamente tratados e restaurados com resina composta, ou com o uso de pinos intra-radiculares de fibra de vidro. Para isso, foram utilizados 30 incisivos inferiores, divididos em 3 grupos de 10 dentes. No grupo "H" os dentes permaneceram hígidos para o teste. No grupo "E", após a endodôntia, os dentes tiveram a abertura endodôntica restaurada com resina composta, e no grupo "P", após a endodontia, foi cimentado um pino de fibra de vidro (FRC Postec Plus, Ivoclar/Vivadent) no conduto radicular e a abertura endodôntica restaurada com resina composta. Após os testes, os grupos não apresentaram diferenças estatísticas (p=0,423). Dessa forma, de acordo com os resultados obtidos na presente pesquisa, pôde-se concluir que dentes anteriores inferiores endodonticamente tratados não diminuem a sua resistência à fratura, se a abertura endodôntica for restaurada com resina composta, ou ainda, se for cimentado pino fibro-resinoso no conduto radicular.
856

Análise da distribuição de tensões em implantes dentários de PEEK pelo método de elementos finitos 3D

Sarot, João Rodrigo January 2008 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia. / Made available in DSpace on 2012-10-24T01:45:39Z (GMT). No. of bitstreams: 1 261027.pdf: 4353804 bytes, checksum: 6be9021b709bbac2e775e9a1c87cd29f (MD5) / O PEEK vem se mostrando um excelente material na substituição do titânio em aplicações ortopédicas. Seus compostos relacionados podem ser fabricados com larga escala de propriedades físicas, mecânicas e de superfície e nos mais diversos formatos. Esta versatilidade abre um novo horizonte de possibilidades no projeto de novos implantes e componentes para reabilitação bucal, especialmente ao se levar em consideração o comportamento biomecânico deste material. O objetivo deste estudo foi comparar, por meio do Método de Elementos Finitos (MEF), a distribuição de tensões ao osso de suporte periimplantar em modelos distintos compostos por componentes e implantes de PEEK com 30% de reforço de fibras de carbono (30% CFR-PEEK) e titânio. Nas simulações, com união perfeita entre implante e osso, o 30% CFR-PEEK apresentou maior concentração de tensões no pescoço do implante e osso adjacente devido a sua menor rigidez e maior deformação em relação ao titânio. Implantes e componentes de 30% CFR-PEEK não mostraram vantagens, no que se refere à distribuição de tensões, quando comparados aos implantes e componentes de titânio. PEEK (poly ether ether ketone) has proved to be an excellent material for the titanium substitute in orthopedic applications. Its related composites can be manufactured with many physical, mechanical and surface properties and in several shapes. This versatility opens a new horizon of possibilities in the development of new implants and components for bucal rehab, especially when the biomechanical behavior of this material is taken into consideration. The aim of this study was to compare, using the three-dimensional finite element method, the stress distribution in the peri-implant support bone in distinct models composed by PEEK components and implants with 30% carbon fiber reinforced (30% CFR-PEEK) and titanium. In the simulations, with a perfect bonding between the bone and the implant, the 30% CFR-PEEK presented higher stress concentration in the implant neck and the adjacent bone due to its lower hardness and higher deformation in relation to the titanium. 30% CFR-PEEK implants and components did not show any advantages in relation to the stress distribution when compared to the titanium implants and components.
857

Avaliação da resposta tecidual e capacidade de mineralização de cimentos que contém compostos biocerâmicos, resinosos e com hidróxido de cálcio /

Bueno, Carlos Roberto Emerenciano. January 2015 (has links)
Orientador: Eloi Dezan Junior / Banca: Luciano Tavares Ângelo Cintra / Banca: Marco Antonio Húngaro Duarte / Resumo: A obturação ideal é uma combinação de um cimento com um material sólido, geralmente guta percha, que corrobora com o escoamento do cimento fluido, espalhando-o e preenchendo possíveis espaços vazios. Em virtude da possibilidade de contato direto com os tecidos periapicais, estes cimentos devem ser biocompatíveis e, se possível, estimular a mineralização para proporcionar selamento apical. Com o objetivo de avaliar, in vivo, a resposta tecidual e a capacidade de mineralização dos cimentos endodônticos Smartpaste® Bio, Sealapex® e Acroseal®, foi realizado implante subcutâneo em 40 ratos Wistar e adotados os períodos experimentais de 7, 15, 30 e 60 dias (10 animais por período de tempo). Cada animal recebeu quatro implantes, três tubos de polietileno com os cimentos a serem testados e um tubo vazio como controle. Após cada período pós-operatório, os animais foram eutanasiados e os tubos de polietileno, juntamente com o tecido circunjacente foram removidos e fixados. Para a análise histológica da espessura da cápsula fibrosa, infiltrado inflamatório e mineralização as peças foram incluídas em historresina, e coradas em HE, Von Kossa ou permaneceram sem coloração para a luz polarizada. Os resultados foram submetidos ao teste de Kruskal Wallis e Dunn (p<0,05). Resultados: Todos os cimentos produziram reação inflamatória moderada nos períodos iniciais. O Smartpaste Bio® apresentou a menor reação inflamatória aos 15 dias (p<0,05). O Sealapex® induziu maior mineralização, seguido do Smartpaste Bio®. O Acroseal® não apresentou indução de mineralização. Conclusão: Ao final do experimento, todos os cimentos testados apresentaram compatibilidade tecidual. Com exceção do Acroseal, todos induziram mineralização. / Abstract: The cleaning and shaping of root canals is essential to achieve biological and mechanical goals in the endodontic treatment, providing the appropriate conical shape for subsequent obturation. The optimal obturation is a combination of a sealer with a central core, usually gutta percha, spreading and filling possible gaps. Once there is a direct contact with periapical tissue, the sealer should be biocompatible and, if possible, stimulate mineralization to perform an apical sealing. In order to evaluate in vivo biological response and tissue mineralization capacity of the endodontic sealers Smartpaste Bio® Sealapex® and Acroseal®, subcutaneous implants in 40 Wistar rats were performed. Analisys were at 7, 15, 30 and 60 days experimental periods (10 animals for each time period). Each animal received four implants, three polyethylene tubes with the sealers in test and one empty tube as control. After each post-operative period animals were euthanized and the polyethylene tubes, along with surrounding tissue were removed and fixed. In order to histologically analysis fibrous capsule thickness, inflammatory infiltrate and mineralization, the pieces were included in historesin and stained in HE, Von Kossa or remained without staining for observation under polarized light. The results were statistically analyzed by Kruskal-Wallis and Dunn (p<0,05). Results: All sealers promoted moderate inflammatory reaction at initial periods. Smartpaste Bio® presented the lowest inflammatory reaction at 15 days period (p<0.05). Sealapex® induced higher mineralization, followed by Smartpaste Bio®. Acroseal® showed no mineralization areas. Conclusion: At the end of the experiment, all tested sealers presented biocompatibility. With exception of Acroseal, all induced biomineralization. / Mestre
858

Avaliação do efeito osteoindutivo do PDGF-BB associado a diferentes carreadores na regeneração óssea em cavidades cirurgicamente criadas /

Oliveira, Júlio César Silva de. January 2015 (has links)
Orientador: Idelmo Rangel Garcia Junior / Coorientadora: Eloá Rodrigues Luvizuto / Banca: Roberta Okamoto / Banca: Joel Ferreira Santiago Junior / Resumo: Objetivos Defeitos ósseos extensos em região maxilo-facial podem ser corrigidos com enxerto autógeno, no entanto as desvantagens desta modalidade terapêutica levam à pesquisa por novos substitutos ósseos. Com isso, avaliamos o comportamento biológico e osteoindutivo do PDGF-BB associado a diferentes carreadores, por meio de análise histológica, histométrica e imunoistoquímica em defeitos críticos realizados em calotas cranianas de ratos. Materiais e método 96 defeitos críticos de 5 mm de diâmetro foram criados em calotas cranianas de ratos. Cada defeito foi aleatoriamente dividido em 8 grupos experimentais (AUT, COA, TCP, TCP+PDGF, END, END+PDGF, BIO, BIO+PDGF), avaliados aos 15 e 30 dias pós-operatórios com relação a histomorfometria e imunoistoquímica. Resultados Os resultados mostraram que houve neoformação óssea em todos os grupos analisados, independentemente do tempo pós-operatório. Aos 30 dias, o grupo TCP só não diferiu do grupo BIO na neoformação óssea (p = 0,1403). Em nenhum dos grupos de biomateriais analisados, o fator de crescimento estimulou o aumento da neoformação óssea (p > 0,05). Conclusão Com a metodologia utilizada, o fator de crescimento associado com os biomateriais testados não induziu neoformação óssea. Relevância clínica Baseado nestes resultados, é necessário desvendar os mecanismos osteoblásticos nas fases iniciais da cicatrização óssea e o seu desfecho em longo prazo, para que a concentração adequada do PDGF-BB possa ser bem empregada com o arcabouço ósseo que mais o favorece para as reconstruções maxilofaciais. / Abstract: Objectives Extensive bone defects in maxillofacial region can be corrected with autograft, however the disadvantages of this type of therapy lead to the search for new bone substitutes. Thus, we evaluated the biological behavior and osteoinductive PDGF-BB associated with different carriers, by histological analysis and immunohistochemical histometric critical defects performed in rats calvaria. Materials and method 96 critical defects were created with 5 mm diameter calvaria of rats. Each defect was randomly divided into eight experimental groups (AUT, COA, TCP, TCP + PDGF, END, END + PDGF, BIO, BIO + PDGF), evaluated at 15 and 30 postoperative days for histomorphometry and immunohistochemistry. Results The results showed new bone formation in all groups, independent of postoperative time. At 30 days, the TCP group just did not differ from BIO group in the new bone formation (p = 0.1403). In none of the groups analyzed biomaterials, growth factor stimulated increase in bone formation (p > 0.05). Conclusion With the methodology used, the growth factor associated with the tested biomaterials did not induce new bone formation. Clinical relevance Based on these results, it is necessary to unravel the osteoblastic mechanisms in the early stages of bone healing and their outcome in the long term, so that the appropriate concentration of PDGF-BB may be well employed with the bone structure that most favors for maxillofacial reconstructions. / Mestre
859

Estudo da distribuição das tensões geradas por implantes odontológicos com diferentes perfis de rosca /

Chimendes, Luis Henrique. January 2009 (has links)
Orientador: José Geraldo Trani Brandão / Banca: José Elias Tomazini / Banca: José Roberto Rodrigues / Resumo: Muitas das características do implante estão relacionadas com sua longevidade, e uma dessas é o perfil de rosca empregado no projeto de sua criação. Assim, este estudo teve como objetivo analisar a distribuição da tensão gerada por implantes com diferentes perfis de rosca, através do método dos elementos finitos, num modelo bidimensional. Foram realizados oito modelos matemáticos de implantes mantendo-se as mesmas dimensões e modelo do conjunto implante e tecido ósseo, houve alteração somente no desenho do perfil de rosca empregado. Através do programa Ansys, simulou-se um carregamento axial de 100 N para todos os modelos, e os resultados das tensões obtidos foram analisados à luz do critério de Von Mises. Desse modo, observaram-se, modificando o desenho da rosca, variações de tensão no implante de até 30%, no osso compacto de até 40%, e no osso esponjoso de até 70%. Levando-se em conta o que foi observado, percebe-se a grande importância no planejamento do desenho das roscas do implante. Dentre os perfis de rosca analisados, dois modelos propostos na inovação obtiveram melhores resultados na distribuição de tensão no tecido ósseo. / Abstract: Many features of the implant are related to their longevity, and one of them is the profile of screw employed in the project of creation. Thus the present study aimed to analyze the distribution of stress generated by implants with different profiles threaded, through the finite element method in a two-dimensional model. Were up eight models of implants and has been the same size and model of the whole implant and bone tissue, there was only change in the design of screw profile employee. Through the program ANSYS, is a simulated axial loading of 100 N for all models, and the results of the tensions were analyzed in light of the criterion of Von Mises. Thus, there were, modifying the design of screw, variations of tension in the implantation of up to 30% in the compact bone of up to 40% and the spongy bone of up to 70%. Taking into account what has been observed, it is very important in planning the design of the threads of the implant. Among the scenarios analyzed threads, two proposed models in innovation obtained better results in the distribution of stress in bone tissue. / Mestre
860

Fratura precoce da porcelana em restaurações com infra-estrutura de zircônia : influência de gradientes térmicos no desenvolvimento e magnitude de tensões residuais e transitórias /

Benetti, Paula. January 2012 (has links)
Orientador: Alvaro Della Bona / Coorientador: Tarcísio José Arruda Junior / Coorientador: John Robert Kelly / Banca: Alexandre Luiz Souto Borges / Banca : Rubens Nisie Tango / Banca : Liliana Gressler May / Banca : Mario Alexandre Coelho Sinhoreti / Resumo: Esse estudo avaliou o desenvolvimento de tensões dentro da porcelana de restaurações metalo-cerâmicas (MC) e de zircônia-porcelana (ZC) como resultado de diferentes taxas de resfriamento a partir de temperaturas acima da transição vítrea (Tg). Restaurações unitárias (coroas) foram fabricadas com 1 ou 2 mm de espessura de porcelana. Termopares foram posicionados nas superfícies de cimentação (T1) e oclusal (T4) e inseridos na interface (T2) e dentro da porcelana (T3). Para o resfriamento rápido, o forno foi aberto imediatamente após o tempo de sinterização e desligado. O resfriamento lento foi obtido pela abertura do forno quando a 50°C abaixo da Tg. Modelos axi-simétricos foram construídos para simulação de tensões térmicas tempo-dependentes usando análise de elementos finitos (AEF). Equações de temperatura em função do tempo obtidas por termopares foram inseridas no modelo como condições das margens. A mudança do coeficiente de expansão térmica, densidade, módulo de cisalhamento, capacidade térmica e da Tg de acordo com a taxa de resfriamento foi considerada para simulação do comportamento da porcelana em temperaturas acima da Tg (visco-elástico). O comportamento dos materiais de infra-estrutura e da porcelana abaixo da Tg foi considerado elástico. A taxa de resfriamento na faixa de temperatura próxima a Tg foi 20°C/min e 900°C/min para resfriamento lento e rápido. Durante o resfriamento lento, os diferentes termopares mostraram temperaturas similares em ambas as coroas. Gradientes de temperatura foram observados no resfriamento rápido da coroa ZC (T1-T4 = 100°C) e, em menor magnitude, para a MC (T1-T4 = 30°C). Os resultados de AEF mostraram diferenças de tensão... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated the development of transient and residual stresses within the porcelain of veneered restorations (zirconia- and metal-based) as a result of different cooling rates from temperatures above the glass transition temperature (Tg). All-ceramic (porcelain on zirconia-based ceramic) and porcelain-fused-to-metal (PFM) molar crowns were fabricated with 1 mm or 2 mm porcelain thickness. Thermocouples were attached to intaglio (T1) and occlusal (T4) surfaces and embedded within the ceramics interface (T2) and inside the porcelain (T3) to acquire temperature readings by time. For fast cooling, the furnace was opened immediately after the holding time and switched off afterward. Slow cooling was determined by opening the furnace when it reached 50 °C bellow the Tg. Axially-symmetric crown-like models were constructed to perform a simulation of time-dependent thermal stresses using finite element analyses (FEA). Time-dependent temperature equations from thermocouples were set as boundary conditions for surfaces of the model. Coefficient of thermal expansion, density, shear modulus, heat capacity and Tg dependency on cooling rate were considered for the porcelain simulation (visco-elastic above Tg). Porcelain below the Tg and the framework materials were considered to behave elastically. The cooling rates at Tg range were 20 °C/min and 900 °C/min for slow and fast cooling. During slow cooling, different thermocouples showed similar temperatures for both zirconia and metal crowns. Remarkable temperature gradients were observed for the fast cooled all-ceramic crown (T1-T4 = 100 °C) and, of lower magnitude, for PFM (T1-T4 = 30 °C). FEA results showed differences... (Complete abstract click electronic access below) / Doutor

Page generated in 0.0778 seconds