• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 568
  • 164
  • 20
  • 18
  • 18
  • 17
  • 17
  • 10
  • 10
  • 9
  • 9
  • 8
  • 4
  • 4
  • 2
  • Tagged with
  • 814
  • 814
  • 518
  • 484
  • 154
  • 137
  • 127
  • 114
  • 101
  • 85
  • 80
  • 77
  • 75
  • 74
  • 60
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
341

Estudo comparativo da interação celular entre quatro tipos de implantes dentários / Comparative study of cellular interactions between four types of dental implants

Alves, Fabiana Ferreira 26 February 2015 (has links)
O tratamento de superfície dos implantes dentários é um critério importante para a osseointegração. Considerando a variedade de modificações das superfícies encontradas, estas podem acelerar ou melhorar o processo de osseointegração. Para tanto foram estudadas as características da composição química e a rugosidade, a partir das quais foram encontradas diferentes respostas celulares em estudos comparativos in vitro. O objetivo deste estudo foi comparar a adesão e o crescimento dos OSTEO-1 em implantes dentários com diferentes tratamentos de superfície. Foram utilizados quatro tipos de implantes dentários comercialmente disponíveis, com os seguintes tratamentos de superfície: (A) jateamento e condicionamento ácido com revestimento de fosfato e cálcio (CaP); (B) duplo condicionamento ácido; (C) condicionamento ácido; (D) oxidação anódica. Os implantes de mesmo tamanho foram fixados com dispositivo biocompatível no fundo dos poços das placas de cultura de 12 poços e cobertas com meio de cultura de células. Os OSTEO-1 foram colocados no corpo do implante. Nos períodos de 24, 48 e 72 horas mais tarde, as culturas foram submetidas ao ensaio de redução de MTT para avaliar a viabilidade celular. Os dados foram utilizados para analisar a adesão celular (24h) e para obter as curvas de crescimento das células (24, 48 e 72h). Os experimentos foram realizados em triplicata. Os dados foram comparados por ANOVA, complementado pelo teste de Tukey (p <0,05). Os OSTEO-1 aderiram ao corpo de todos os tipos de implantes testados. A maior taxa de crescimento celular foi observada em culturas semeadas sobre tratamento de superfície A. O menor crescimento celular foi apresentado por culturas semeadas no tratamento de superfície D (p <0,05). Com base nesta investigação in vitro é possível concluir que todos os implantes dentários testados, independentemente do tratamento de superfície, não são citotóxicos para os OSTEO-1. No entanto, as características físico-químicas do tipo de tratamento de superfície dos implantes dentários influencia o crescimento celular. A superfície A pareceu ter o comportamento mais compatível com os OSTEO-1, uma vez que promoveu mais crescimento celular. / The surface treatment of dental implants is a major feature for osseointegration. The variety of surface modifications found may be speed up or enhance the osseointegration process. In much was studied the chemical composition and characteristics of roughness, from which found different cellular responses in comparative studies in vitro.The aim of this study was to compare the adhesion and growth of osteoblast-like cells in response to dental implants characterized by different superficial treatments. Four types of dental implants with different superficial treatments were used. The commercially available implants presented the following superficial characteristics: (A) sandblasted with acid-etched and calcium phosphates (CaP) coating; (B) double acid-etched; (C) anodized, or (D) acid-etched. The implants of the same size (n= 3 per group/experimental time) were fixed with a biocompatible device on the bottom of the wells of 12 wells cell culture plates and covered with cell culture medium. Osteoblast-like cells (Osteo 1 cell line) were plated on the top of the implants (5x104 cells/implant). Twenty-four, 48 and 72 hours later, the cultures were submitted to the MTT reduction assay to assess cell viabilities. Data was used for analyze cell adhesion (24 h) and to obtain cell growth curves ( 24, 48 and 72 h). The experiments were done in triplicate. Data were compared by ANOVA complemented by the Tukey\'s test (p<0.05). Osteoblast-like cells adhered on the top of all types of implants tested. The highest cell growth was observed in cultures plated on the top of sandblasted with acid-etched and CaP coating surfaces. The smallest cell growth was presented by cultures plated on double acid-etched surfaces (p < 0.05). Based on this in vitro investigation, it is possible to conclude that all dental implants tested irrespective to the surface treatment, are non-cytotoxic for osteoblast-like cells. However, the physicochemical chacteristics of the type of dental implants surface treatment influences the cell growth. In fact, the surface treated by sandblasting with acid-etched and CaP coating seemed to the most compatible with osteoblast-like cell biology, once it promoted the highest cell growth.
342

O bombardeamento da superfície de titânio com íons de argônio influencia a resposta biológica de pré-osteoblastos / Argon ions bombardment of titanium surface influences preosteoblastic biological behavior

Moura, Carlos Eduardo Bezerra de 14 December 2007 (has links)
As propriedades da superfície do implante têm papel crítico na indução das respostas celulares necessárias para o sucesso do implante. Os objetivos deste trabalho foram investigar o efeito do bombardeamento com íons de argônio sobre a superfície de titânio comercialmente puro (TiCP) e sua influencia na interação célula-superfície. Superfícies bombardeadas e lisas foram avaliadas quanto à topografia, rugosidade e molhabilidade. Ensaios de adesão, proliferação, atividade de fosfatase alcalina (ALP) e expressão de osteocalcina (OC) foram conduzidos usando células MC3T3-E1 cultivadas sobre essas duas diferentes superfícies. Os níveis de rugosidade na superfície bombardeada e lisa foram 0,11µm and 0,027µm, respectivamente. A Microscopia eletrônica de Varredura (MEV) e Microscopia de força atômica (AFM) também revelaram rugosidade uniforme nestas amostras. A molhabilidade foi maior na superfície bombardeada. O número de células aderidas (30 e 60 min) foi significativamente maior sobre a superfície bombardeada. A proliferação celular depois de 3 e 7 dias também foi maior na superfície bombardeada. A atividade de ALP e expressão de OC não apresentaram diferença significativa entre as superfícies. Esses dados nos levam a propor que a técnica processamento a plasma em atmosfera de argônio com uso de cátodo planar é uma excelente ferramenta para obtenção de biomateriais que favoreçam a osseointegração. / Titanium surfaces were modified by argon ions bombardment aiming to evaluate the influence of the treatment on cell-surface interaction. The effects of topographic (roughness, microstructure) and physiochemical (wettability - contact angle) parameters on the morphology, adhesion, proliferation and MC3T3-E1 preosteoblasts differentiation were analyzed. No-treated surfaces (smooth) were used as a control. The levels of roughness observed in bombarded and smooth titanium surfaces were of 0.11µm and 0.027µm respectively. Scanning electron microscopy (SEM) and atomic force microscopy (AFM) analysis showed that the roughness distribution was uniform. The wettability increased in treated surfaces. The number of attached cells (30 and 60min) was significantly higher on the bombarded surface, as well as, cell proliferation after 3 and 7 days was also significantly higher on ion-bombarded surface. The ALP activity and OC expression did not show not significant differences between the surfaces. Based on the results showed one can propose that the bombardment of titanium surfaces with argon ions is an excellent procedure for obtaining biomaterials and improve the osseointegration.
343

Avaliação da deformação gerada na região peri-implantar de prótese fixa implantossuportada, com a utilização de extensômetros lineares elétricos / Evaluation of peri-implant bone deformation of a mandibular cantilevered implant-supported prosthesis, with the use of strain gages

Suedam, Valdey 07 August 2009 (has links)
O comportamento mecânico das próteses parciais fixas implanto-suportadas são foco de vários estudos, onde o entendimento do processo de transmissão de forças mastigatórias e suas reações na estrutura óssea peri-implantar ainda não são totalmente compreendidos. Por isso, o objetivo deste trabalho foi verificar a deformação gerada na região peri-implantar de prótese parcial fixa mandibular. Para isto foi utilizado um modelo de poliuretano em forma de U simulando o osso mandibular com dois implantes hexágono externo de 3,75mm de diâmetro por 13mm de comprimento, nos quais foram fixados intermediários multi-unit. O trabalho apresentou dois grupos divididos de acordo com o tipo de liga das infraestruturas (CoCr ou PdAg) os quais foram submetidos a quatro situações de aplicação de carga. Foram aplicadas forças de 300N, nos pontos de referência pré-determinados na barra entre os implantes e na extremidade livre (5mm, 10mm e 15mm de cantilever). Foram realizadas leituras das deformações geradas na distal, lingual, mesial e vestibular de cada implante, com o uso de extensômetros lineares elétricos, as quais foram correlacionadas com a teoria de remodelação óssea proposta por Frost. Os resultados do estudo demonstraram que a deformação é influenciada pelo ponto de aplicação de carga e pelo módulo de elasticidade da liga da barra. A deformação é diretamente proporcional ao comprimento do cantilever, onde comprimentos maiores do que 10mm provocam tensões que superam a tensão máxima fisiológica proposta pela teoria de Frost. / The mechanical behavior of implant-supported prosthesis is focus of some studies, with the process of bite forces transmissions and its peri-implant bone reactions is not completely understood yet. Therefore, the aim of this study was to verify the deformation in peri-implant region of mandibular fixed partial prosthesis. A U shaped polyurethane model was used to simulated the mandibular bone with two external hexagon implants with 3.75mm of diameter an 13mm of length, provided with multi-unit abutments. Two groups were formed according to the type of alloy of the framework (CoCr or PdAg), which were submitted to four load conditions. Loads of 300N were applied, in the predetermined points on the framework between the implants and the cantilever (5mm, 10mm and 15mm distal to the terminal implant). Readings of the deformations generated on the distal, lingual, mesial and bucal aspects of each implant were obtained with the use of strain gages, which were correlated to the theory proposed by Frost on bone remodeling. The results of the study demonstrated that deformation is influenced by the point of load application and by the elastic modulus of the alloy of the framework. The deformation is directly proportional to the cantilever length. Lengths bigger than 10mm generate tensions that exceed the maximum effective strain proposed by Frost.
344

\"Análise prospectiva da estabilidade dos tecidos moles ao redor de implantes imediatos com restaurações imediatas em incisivos centrais superiores\" / Prospective analysis of the soft tissue stability around the immediate implant with immediate restoration in central superior incisive.

Camargo, Luiz Otavio Alves 23 March 2007 (has links)
Os implantes imediatos que recebem restaurações imediatas vêm sendo apresentados na literatura como uma opção de tratamento confiável para a reposição de dentes condenados. No entanto, recentemente, dúvidas com relação à estabilidade dos tecidos periimplantares utilizando esta técnica têm sido levantadas. Neste estudo prospectivo, doze pacientes tiveram seus incisivos centrais superiores condenados substituídos por implantes imediatos e restaurações imediatas. Durante 18 meses, foram acompanhados o comprimento das coroas implanto-suportadas e a distância entre a ponta das papilas e a borda incisal dos dentes vizinhos. Não foi observada diferença estatisticamente significativa entre as medidas obtidas. Os resultados obtidos podem ser atribuídos ao rigoroso critério de seleção dos casos e a técnica cirúrgica aplicada. Pode-se afirmar que os tecidos moles periimplantares de implantes imediatos com restaurações imediatas, mantiveram-se estáveis ao longo dos 18 meses de observação seguindo-se os critérios de seleção e execução desse estudo. / The immediate implants that receive immediate restorations have been presented in literature as a reliable alternative to the replacement of condemned teeth. Recently, however, doubts regarding the perimplantar tissue stability have been raised. In this prospective study, twelve patients had their central maxillary incisor replaced by immediate implant and immediate restoration. After 18 months the papillae height and the Zenith of implant supported crown were compared to the dimensions before dental extraction. No statistically significant difference was observed between the obtained measurements. The authors justify the obtained results to the rigorous selection criteria of the cases that had been part of this sample and the surgical technique applied. In the selections criteria and executions followed in this work to the immediate implant placement and immediate restorations, we can state that the soft perimplantar tissues have been remained stable for the 18 months? observation.
345

Avaliação da passagem de micro-organismos por meio da interface entre implantes e conectores protéticos com parafusos convencionais planos e experimentais cônicos pela técnica DNA-Checkerboard / Evaluation of microorganisms leakage through the interface between implants and prosthetic connectors with conventional plane and experimental conical screws by DNA-Checkerboard technique

Carla Gabaldo Pessoa dos Santos 03 March 2017 (has links)
Apesar da confiabilidade e da sobrevivência relacionadas aos tratamentos com implantes, falhas das reabilitações orais implanto-suportadas ainda são persistentes. Estas falhas podem causar tanto danos mecânicos -como o afrouxamento do parafuso de retenção devido à instabilidade das conexões- quanto danos biológicos -como as reações inflamatórias nos tecidos peri-implantares devido à ocorrência de infiltração bacteriana através da interface implante/pilar e a consequente colonização do interior dos implantes e seus componentes. Os mecanismos responsáveis por estas falhas mecânicas/biológicas dos sistemas de implantes não estão totalmente elucidados, e modificações nos modelos das conexões protéticas e dos parafusos de retenção vêm sendo desenvolvidas com o intuito de aumentar a estabilidade das conexões e minimizar estas intercorrências. Entretanto, a literatura relativa à configuração ideal destas modificações e seus fatores determinantes envolvidos ainda é inconclusiva. Assim, os objetivos do presente do estudo foram avaliar microbiologicamente por meio da técnica de hibridização DNA-Checkerboard, a ocorrência de infiltração bacteriana do meio externo para o interior dos implantes através das diferentes interfaces implante/pilar em dois diferentes sistemas de conexão de implantes, hexágono externo (HE) e triângulo interno (TI), com parafusos de retenção de pilares planos convencionais e parafusos experimentais cônicos. Quarenta e oito implantes dos dois tipos de conexão foram analisados, sendo estes HE ( n = 24) ou TI (n = 24). Os pilares foram fixados a implantes com parafusos convencionais ou parafusos cônicos experimentais. Após a incubação em saliva, a hibridização DNA Checkerboard foi utilizada para identificar e quantificar até 38 espécies bacterianas na área interna dos implantes. Para análise estatística utilizou-se o teste de Kruskal-Wallis seguido de pós-testes de Bonferroni para comparações múltiplas. Vinte e quatro das trinta e oito espécies estudadas, incluindo patógenos putativos periodontais, foram encontradas colonizando as superfícies internas dos implantes HE e TI. Peptostreptococcus anaerobios (P = 0,003), Prevotella melaninogenica (P <0,0001) e Candida dubliniensis (P <0,0001) apresentaram diferenças significativas entre os diferentes grupos. As médias de contagem microbiana total (× 104, ± DP) para cada grupo foram registradas como: G1 (0,27 ± 2,04), G2 (0 ± 0), G3 (1,81 ± 7,50) e G4 (0,35 ± 1,81). As diferentes geometrias das conexões de implantes e parafusos apresentaram distintos níveis de penetração microbiana através da interface implante-pilar. Os implantes ligados com parafusos de pilar de cabeça cônica experimental apresentaram contagens menores de micro-organismos quando comparados com os parafusos convencionais. / Despite the reliability and high success rates related to treatment with implants, failures of implant-supported oral rehabilitation are still persistent. These failures can cause both mechanical damage, such as loosening the retaining screw connections due to instability, as biological damage, such as inflammatory reactions in periimplants tissues due to the occurrence of bacterial leakage along the implant/abutment interface and the subsequent colonization of the subsequent colonization of the internal/inner parts of the implants and components. The mechanisms responsible for these mechanical/biological failures of implant systems are not fully elucidated, and changes to the models of prosthetic connections and retaining screws have been developed in order to increase the stability of connections and minimize these problems. However, the literature related to these changes and its impact on the implant-components stability is still inconclusive. The objective of this study was to evaluate microbiologically by the DNA-Checkerboard hybridization, the occurrence of bacterial leakage from the external environment to the interior of the implant through these different implant/abutment interface. For the study will be evaluated two different implant connections, one external hexagonal (EH) and other internal triangle (IT), with either conventional and experimental tapered screws abutment. Forty-eight two-part implants with external hexagon (EH; n = 24) or tri-channel internal (TI; n = 24) connections were investigated. Abutments were attached to implants with conventional flat-head or experimental conical-head screws. After saliva incubation, Checkerboard DNA-DNA hybridization was used to identify and quantify up to 38 bacterial colonizing the internal parts of the implants. Kruskal-Wallis test followed by Bonferroni\'s post-tests for multiple comparisons was used for statistical analysis. Twenty-four of thirty-eight species, including putative periodontal pathogens, were found colonizing the inner surfaces of both EH and TI implants. Peptostreptococcus anaerobios (P = 0.003), Prevotella melaninogenica (P < 0.0001), and Candida dubliniensis (P < 0.0001) presented significant differences between different groups. Means of total microbial count (×104 , ±SD) for each group were recorded as follows: G1 (0.27 ± 2.04), G2 (0 ± 0), G3 (1.81 ± 7.50), and G4 (0.35 ± 1.81). Differences in the geometry of implant connections and abutment screws have impacted the microbial leakage through the implant-abutment interface. Implants attached with experimental conical-head abutment screws showed lower counts of microorganisms when compared with conventional flat-head screws.
346

Avaliação da infiltração bacteriana através da interface implante-conector protético sob aplicação de carga - avaliação in vitro pelo método DNA Checkerboard / Bacterial leakage along the implant-abutment interface after loading simulation. In vitro evaluation by DNA Checkerboard method

Cássio do Nascimento 03 September 2010 (has links)
A passagem bacteriana através da interface entre implante e conector protético com a conseqüente colonização dos implantes tem sido relatada em diversos estudos na literatura. O objetivo deste estudo in vitro foi avaliar a passagem de espécies bacterianas da saliva humana para o interior dos implantes através da interface implante-conector protético após simulação de carga cíclica controlada. Foram avaliados 60 implantes de um sistema de 2 componentes e seus respectivos conectores protéticos, divididos em 3 grupos de acordo com o tipo de conexão utilizado: hexágono externo, hexágono interno e cone morse. Cada grupo foi dividido em 2 subgrupos (n=10), submetidos à aplicação de carga e controle. Previamente ao teste, amostras do interior dos implantes foram coletadas para servirem como controle negativo da contaminação. Os conectores foram adaptados aos implantes com um torque final de 20 Ncm, de acordo com a recomendação do fabricante. Os conjuntos foram imersos em saliva humana e submetidos a 500.000 ciclos de carga com uma força de 120 N ou incubados em 35°C durante 7 dias sem aplicação de carga (controle). A eventual contaminação do interior dos implantes foi avaliada após o período experimental usando o método DNA Checkerboard. Microrganismos foram encontrados no interior dos implantes de todos os tipos de conexões avaliadas após o teste de carga cíclica. Os grupos cone morse apresentaram os menores valores de contagem bacteriana nos grupos submetidos a ciclagem de carga e controle. Os implantes submetidos à carga cíclica apresentaram maiores valores de contagem bacteriana do que seus respectivos controles no hexágono externo e interno. Nenhuma espécie bacteriana foi encontrada abrigando o interior dos implantes antes do teste de contaminação (controle negativo). Os implantes do grupo cone morse apresentaram menores quantidades de microrganismos nas duas condições testadas. Pode-se concluir que espécies bacterianas provenientes da saliva humana podem penetrar através da interface implante-conector protético com ou sem a simulação de carga cíclica, e que a aplicação de carga contribuiu para o aumento da contaminação nos implantes com conexão hexagonal externa e interna. / Bacterial leakage along the implant-abutment interface with consequent species harboring the inner parts of two-part dental implant systems has been reported. The aim of this in vitro study was to evaluate the bacterial leakage from human saliva to the internal part of the implants along the implant-abutment interface under loading conditions. Sixty dental implants, 20 for each external or internal hexagon and morse cone connection, and their conical abutments were used in this study. Each connection was sub-divided in 2 groups (n=10), loaded implants and control (unloaded). Previously to the bacterial leakage test, samples from the inner parts of the implants were collected with sterile microbrushes as negative control of contamination. The abutments were tightened to 20 Ncm on the implants. The assemblies were immersed in human saliva and loaded with 500,000 cycles of 120 N in experimental or incubated for 7 days at 35°C in control group. After this period, possible contamination of the internal parts of the implants was evaluated using the DNA Checkerboard method. Microorganisms were found in the internal surfaces of all connections evaluated. Morse cone connection presented the lowest count of microorganisms in control and loading group. Loaded implants present higher counts of microorganisms than control group in external and internal hexagon. No microorganisms were found in the samples recovered from the implants before contamination test (negative control). It can be concluded that bacterial species from human saliva may penetrate along the implant-abutment interface under unloaded and loaded conditions, and morse cone connection presented the lowest count of microorganisms.
347

Osteoblastic cell adhesion on implant surfaces contaminated by Aggregatibacter actinomycetencomitans and treated by photodynamic therapy and chemical decontamination / Adesão de células osteoblásticas em superfícies de implantes contaminadas por Aggregatibacter actinomycetencomitans e tratadas com terapia fotodinâmica e descontaminação química

Balderrama, Ísis de Fátima 06 April 2018 (has links)
The decontamination process of titanium implants surface is important for the successful treatment of peri-implantitis. The methods of decontamination can be classified in two major groups: chemical or physical. However, the best method of decontamination of implant surfaces is yet undertermined. The aim of this study is to analyze the effectiveness of decontamination of titanium implants surface by chemical conditioning agents and photodynamic therapy, by Scanning Electron Microscopy (SEM) and to analyze the adhesion and proliferation of osteoblastic cells on the previously decontaminated surfaces. Commercially available implants of different brands: Biomet 3i® (Nanotite NT; Osseotite - OT), Straumann® (SLActive SLA) and Neodent® (Acqua Drive CM ACQ; Neoporos Drive CM CM) were acquired in the market and analyzed in SEM images in 3 different areas (n= 1/group) to determine surface roughness parameters and wettability properties. After that, the surface of dental implants was inoculated with Aggregatibacter actinomycetemcomitans (A.a.) strains for 4 days and prepared for SEM analysis to determine the percentage area of contamination in a software for image analysis. Samples were then decontaminated by two different chemical treatments (citric acid 10% and ethylenediamine tetraacetic acid EDTA - 24%) and photodynamic therapy (methylene blue associated with LASER), both with a 3-minutes application time. In the control group, surfaces were decontaminated with chlorhexidine 0.12% for 3 minutes. The area of decontamination was determined in ImageJ software for SEM images analysis. After decontamination, the adhesion and proliferation of human osteoblastic osteosarcoma cell lineage (Saos-2) on the surface of uncontaminated sterile implants (control; n: 1/period) and decontaminated implants (n: 3/period/group) were investigated. Saos-2 cells [5x104] were seeded on implant surfaces and incubated for 24h (adhesion assay) and 72h (proliferation assay), determined on SEM images. No significant differences were found among the different implants regarding roughness parameters, with exception Rv (SLA: 19.57}4.01 vs. OT: 8.36}7.91; p=0.0031). Chemical composition varied among implants depending on surface treatment, with all groups showing prevalence of Titanium. Values showed greater contact angle (wettability analysis) for NT (hydrophobic) and smaller for ACQ (highly hydrophilic) (p<0.0001). Nanotite/Biomet 3i® showed significantly greater percentage of area contaminated by bacteria (68.19% } 8.63%; p=0.050; Kruskal Wallis/Dunn) than ACQ (57.32% } 5.38%). Osseotite/Biomet 3i® resulted in a smaller remaining contaminated area (50.89% } 9.12%) after decontamination treatments. Increased Saos-2 cells adhesion and proliferation were observed on SLA after 24h (p= 0.0006; ANOVA/Tukey) and 72h (<0.001; ANOVA/Tukey). Decontaminated groups showed significantly less number of cells adhered to the surfaces at 24h and 72h than uncontaminated controls (p < 0.005; ANOVA post hoc Sidak). Regarding decontamination methods, no differences in the number of cells attached to implants treated by photodynamic therapy and chemical agents compared to chlorhexidine at 24h, but implants treated by photodynamic therapy and chemical agents showed greater number of cells attached after 72h. These findings suggest that surface characteristics influenced bacterial contamination and decontamination of implant surfaces; none of the decontamination methods were able to completely remove bacterial contamination, impairing cell adhesion and spreading. These findings may explain the varying clinical results of decontamination methods in re-osseointegration. / O processo de descontaminação de implantes de titânio é importante para o sucesso do tratamento da peri-implantitite. Os métodos de descontaminação podem ser classificados em dois maiores grupos: químico ou físico. Entretanto, o melhor método de descontaminação de superfícies de implantes está ainda indeterminado. O objetivo desse estudo é analisar a efetividade da descontaminação de implantes com superfície de titânio por agentes condicionantes químicos e terapia fotodinâmica, por Microscopia Eletrônica de Varredura (MEV) e analisar a adesão e proliferação de células osteoblásticas previamente com superfícies descontaminadas. Implantes disponíveis comercialmente de diferentes marcas: Biomet 3i® (Nanotite NT; Osseotite - OT), Straumann® (SLActive SLA) e Neodent® (Acqua Drive CM ACQ; Neoporos Drive CM CM) foram adquiridos no mercado e analisados em imagens de MEV em 3 diferentes áreas (n=1/grupo) para determinar o parâmetro de rugosidade da superfície e a propriedade de molhabilidade. Depois disso, a superfície dos implantes dentários foi inoculada com cepa de Aggregatibacter actinomycetemcomitans (A.a.) por 4 dias e preparada para análise da MEV afim de determinar a área de porcentagem da contaminação em um software de análise de imagem. Amostras foram então descontaminadas por dois diferentes tratamentos químicos (ácido citrico 10% e ácido etilenodiamino tetraacético- EDTA 24%) e terapia fotodinâmica (azul de metileno associado com LASER), ambos em 3 minutos com tempo de aplicação. No grupo controle, os implantes foram descontaminados com clorexidina 0.12% por 3 minutos. A área de descontaminação foi determinada no software Image J para análise das imagens de MEV. Depois da descontaminação, a adesão e proliferação da linhagem de células de osteosarcoma osteoblástica humana (Saos-2) em superfícies não contaminadas de implantes estéreis (controle; n: 1/período) e implantes descontaminados (n: 3/período/grupo) foram investigados. Células da Saos-2 [5x104] foram cultivadas sobre as superficies dos implantes e incubadas por 24 horas (ensaio de adesão) e 72 horas (ensaio de proliferação) e determinadas em imagens de MEV. Não foram encontradas diferenças significantes entre os implantes em relação a parâmetros de rugosidade, com exceção para Rv (SLA: 19.57±4.01 vs. OT: 8.36±7.91; p=0.0031). Houve variação na composição química dos implantes de acordo com o tratamento de superfície, com todos os grupos mostrando prevalência do Titânio. Houve maior ângulo de contato (análise de molhabilidade) para NT (hidrofóbico) e menor para ACQ (altamente hidrofílico; p<0.0001). Nanotite/Biomet 3i® mostrou porcentagem significativamente maior de área contaminada por bactérias (68.19% ± 8.63%; p=0.050; Kruskal Wallis/Dunn) que ACQ (57.32% ± 5.38%). Osseotite/Biomet 3i® resultou em significativa menor área contaminada remanescente (50.89% ± 9.12%) depois dos tratamentos de descontaminação. Foi observada maior adesão e proliferação de células Saos-2 em SLA após 24 (p= 0.0006; ANOVA/Tukey) e 72 horas (<0.001; ANOVA/Tukey). Os grupos descontaminados mostraram número significativamente menor de células aderidas às superfícies nos dois períodos de tempo comparativamente aos controles não contaminados (p < 0.005; ANOVA post hoc Sidak). Em relação aos métodos de descontaminação, não foram observadas diferenças no número de células aderidas aos implantes tratados por terapia fotodinâmica e agentes químicos comparados com clorexidina em 24 horas, mas os primeiros mostraram maior número de células aderidas depois de 72 horas. Esses achados sugeriram que as características de superfície influenciaram a contaminação bacteriana e a descontaminação de superfície; nenhum método de descontaminação é capaz de remover completamente a contaminação bacteriana, dificultando a adesão e proliferação celular. Esses achados poderiam explicar a variação de resultados clínicos nos métodos de descontaminação e obtenção de reosseointegração.
348

Avaliação da distribuição das tensões ao redor de implantes em diferentes níves de inserção / Stress distribution around dental implants placed at different depths: a photoelastic evaluation

Zanardi, Piero Rocha 16 February 2017 (has links)
A perda óssea progressiva ao redor da plataforma dos implantes dentários é um desafio a ser vencido na clínica, uma vez que, interfere na manutenção e controle dos tecidos peri-implantares e pode afetar a estética. Esta pesquisa teve como objetivo avaliar a concentração de tensões ao redor de diferentes implantes dentários, variando a macrogeometria, conexão protética e profundidade da inserção da plataforma protética, sob carregamento axial ou oblíquo. Foram criados três modelos de resina fotoelástica para cada tipo de implante avaliado (hexágono externo, hexágono externo wedge, hexágono interno e cone Morse). Cada corpo de prova se diferenciou pelo posicionamento da plataforma do implante em relação à margem superior do bloco, em três posições diferentes: I - plataforma posicionada 2mm abaixo da margem do bloco; II - plataforma posicionada no mesmo nível da margem do bloco; III - plataforma posicionada 2mm acima da margem do bloco. Foi aplicada uma força de 100N através de um dispositivo instalado sobre pilares retos e angulados, simulando um carregamento axial e oblíquo respectivamente. Um total de 4 pontos foram avaliados de um lado do implante. Dados quantitativos foram coletados e utilizados para análise estatística. A regressão linear múltipla mostrou relação entre a distribuição das tensões com relação à profundidade de inserção independentemente do tipo de conexão protética ou do carregamento oclusal. O grupo I (2mm abaixo da margem) foi o que apresentou os menores valores (p<0.05) de tensão quando comparado com os outros grupos (II e III). De acordo com as limitações deste estudo pode-se concluir que a macrogeometria, profundidade de inserção da plataforma e tipo de carregamento oclusal influenciam no comportamento da distribuição das tensões ao redor dos implantes. Em relação à conexão protética, os resultados mostraram padrões de franjas semelhantes independentemente do tipo de conexão / The progressive bone loss at the neck of dental implant is a clinical concern since it affects the maintenance of dental esthetics. The stress concentration, the connection type and the microgap appear to be factors that cause alterations at the marginal bone level. The aim of this research was to evaluate the stress concentration around different dental implants, varying the macrogeometry, prosthetic connection and depth of the insertion of the prosthetic platform, under axial or oblique loading. Three blocks of photoelastic resin for each type of implant connection (external hexagon, external hexagon flattened, internal hexagon and Morse taper) were built. Each block differed in the position of the implant platform in relative to the upper margin of the block: I (2mm below), II (at the same level) and III (2mm above). A force of 100N was applied to both a straight and tilted abutments. A multiple linear regression showed the relation between the stress distribution and the insertion depth. For all the implant types, both with straight and tilted abutments, Group I presented the lowest stress concentration around the fixture when compared to group II and III (p<0,05). According to the limitations of this study it could be concluded that the macrogeometry, depth of insertion of the platform and type of occlusal loading influence the behavior of the distribution of stresses around the implants. Regarding the prosthetic connection, the results showed similar patterns of fringes regardless of the type of connection
349

Análise do comportamento biomecânico por meio de elementos finitos, de próteses parciais fixas, apoiadas sobre diferentes conexões entre dente-implante / Fit evaluation on prefabricated abutments and transmitted stress to implants by I beam superstructures as a function of implants number

Lencioni, Karina Albino 03 July 2015 (has links)
Limitações anatômicas, falhas na osseointegração, necessidade de esplintagem de dentes naturais com comprometimento periodontal podem levar a união dente-implante. Alguns autores relatam que a união com conexão da prótese semi-rígida pode causar a intrusão do dente natural, por esse motivo o uso de conexão da prótese em monobloco vem causando maior sucesso. Com isso o objetivo do trabalho é analisar a distribuição de tensão pelo método dos elementos finitos, em prótese sobre conexão dente-implante alterando o tipo de conexão da prótese, rígida e semi-rígida, e o tipo de conexão do implante, cone morse ou hexágono externo, em regiões de ligamento periodontal, osso periimplantar e conjunto prótese e implante. Para a realização do trabalho foi realizado o escaneamento dos dentes 45 e 46, através de um microtomógrafo (SkyScan, Kontich, Bélgica), as imagens em 3D dos implantes e componentes protéticos foram cedidas pela empresa Neodent (Curitiba, PR, Brasil). Nesse trabalho foram desenvolvidos quatro modelos tridimensionais todos eles representavam um hemiarcada mandibular direita com presença do dente 45 e ausência do dente 46 e 47, foram feitos modelos com implante com conexão hexagonal externa e prótese com conexão rígida ou semi-rígida, e modelos com implantes cone morse com prótese com conexão rígida ou semi-rígida. As modelagens foram realizadas no programa Rhinoceros 3D (Robert McNeel& Associates, EULA, EUA) o programa utilizado para análise dos elementos finitos foi o ABAQUS FEA (Simulia, Providence, RI, EUA).Os resultados mostraram que modelos com conexão do implante em hexágono externo geraram uma tensão de tração na distal do ligamento periodontal com presença de tensão de compressão da região apical do ligamento periodontal, sugerindo uma possível rotação do elemento dentário com posterior intrusão, independentemente do tipo de conexão protética. Já em modelos com implantes cone morse observamos uma maior distribuição de tensão no ligamento sugerindo até mesmo uma anulação da forças de tração, também independentemente do tipo de conexão da prótese. Foi observado também que próteses com implantes cone morse sofreram maior distribuição de tensão, que próteses com implantes hexágono externo, porém foi observado maior concentração de tensão na região de união pilar/implante nos dois tipos de implantes usados, não dependendo do tipo de conexão da prótese. Outro resultado observado foi um maior acúmulo de tensão no osso cortical que no osso medular, e também maior tensão no osso cortical em modelos com implante cone morse que em modelos com implante hexagonal externo, para os dois tipos de conexão da prótese. Com isso, concluímos que independentemente do tipo de conexão da prótese, o uso de implantes cone morse na união dente-implante gerou melhores resultados que o uso de implantes hexágono externo. / Anatomical limitations, failures in osseointegration, need for splinting of natural teeth with periodontal disease can lead to tooth-implant union. Some authors report that the union with the semi-rigid prosthesis connection can cause the intrusion of the natural tooth, therefore the use of the prosthesis connection monobloc is causing greater success. Thus the objective of this study is to analyze the stress distribution by finite element method, in denture on implant-tooth connection by changing the type of prosthesis connection, rigid and semi-rigid, and the type of implant connection, morse taper or external hexagon in areas of periodontal ligament, peri-implant bone and joint prosthesis and implant. To carry out the work was carried out scanning of teeth 45 and 46, through a microtomography (SkyScan, Kontich, Belgium), the 3D images of prosthetic implants and components were provided by Neodent company (Curitiba, Brazil). In this work we developed four-dimensional models they all represented a mandibular right hemi-arch with presence and absence of the tooth 45 of the tooth 46 and 47 models were made with implants with external hex connection and prosthesis with rigid or semi-rigid connection, and models with implants morse taper with prosthesis with rigid or semi-rigid connection. The modeling was performed in Rhinoceros 3D program (Robert McNeel & Associates EULA, USA) program used for finite element analysis was ABAQUS FEA (SIMULIA, Providence, RI, USA) .The results showed that implant connection with models in hexagon generated a distal external tensile stress in the periodontal ligament with presence of the apical region compressive stress of the periodontal ligament, suggesting a possible rotation of the tooth with subsequent intrusion, regardless of the type of prosthetic connection. Already in models with morse taper implants found a higher voltage distribution ligament even suggesting a reversal of traction, also regardless of the type of prosthesis connection. It was also observed that prostheses with morse taper implants suffered greater stress distribution, which aids with external hex implants, but there was a higher concentration of stress in the joining region pillar / implant in the two types of implants used, not depending on the type of connection prosthesis. Another result was observed a higher voltage accumulation in the cortical bone in the cancellous bone, and also higher voltage on cortical bone models in morse taper implant external hexagon implant models for the two types of prosthesis connection. Thus, we conclude that regardless of the type of prosthesis connection, using morse taper implants in implant-tooth union gave better results than the use of external hex implants.
350

Validação de uma máquina de testes de flexão rotacional e seus efeitos em implantes de hexágono externo e interno / Validation of a rotating bending machine and its effects on external and internal hexagon implants

Oliveira Neto, Luiz Alves de 24 April 2013 (has links)
O sucesso do tratamento com implantes dentários depende do conhecimento teórico-prático do profissional, condições biológicas do paciente, e das propriedades mecânicas dos seus componentes. Dois testes de fadiga podem avaliar as propriedades mecânicas destes materiais: ensaios monotônicos unidirecionais e testes de flexão rotacional. A vantagem do dispositivo de flexão rotacional é o ensaio mais rápido que fornece dados relevantes e uma previsão mais realista da longevidade clínica. Oliveira-Neto (2011) avaliou o dispositivo de flexão rotacional desenvolvido por Ferreira (2010), e mostrou que componentes do dispositivo necessitavam ser revistos para assegurar melhor fixação do implante, controle de temperatura, frequência e permitir modificação do momento de força aplicado aos espécimes. O objetivo deste trabalho foi confeccionar e avaliar novos componentes para o dispositivo de flexão rotacional de Ferreira (2010) e avaliar seus efeitos em sistemas de implante de hexágono externo e interno. Os grupos testados foram: Aimplantes Hexagono Externo (HE) com munhão (UCLA); B- implantes HE com Pilar Cônico; C- implantes Hexagono Interno (HI) com munhão (UCLA); D- implantes HI com Pilar Cônico. O novo método consistiu em modificações no: porta implante, porta rolamento, centralizador do implante, material de fixação (resina acrílica). As amostras foram submetidas a ciclagem em torno do seu eixo longitudinal enquanto uma extremidade estava fixada em um mandril à 45o e a outra extremidade recebia a carga. O objetivo foi determinar o nível de carga em que 50% dos espécimes sobreviveram e 50% fraturaram antes de 106 ciclos girando a 16Hz. Assim, a resistência a fadiga (F50) foi determinada através da técnica staircase analysis. Após a ciclagem, os componentes que não apresentaram falhas tiveram o destorque de remoção mensurado eletronicamente, e todas as amostras foram analisadas através de microscópio eletrônico de varredura, radiografia e fotografia digital. Os resultados mostraram que os grupos UCLA têm maior resistência à fadiga. O sistema de HI-UCLA mostrou um desempenho mais estável, com uma resistência igual ao HE. Os grupos com Pilar Cônico apresentaram falhas clinicamente melhor, permitindo a substituição de componentes protéticos. Os danos mais graves ocorreram em ambos os grupos HE, com danos aos implantes. O método de desinclusão do implante da resina precisa ser revisto visando a obtenção de imagens sem artefatos. O dispositivo de Ferreira (2010) associado às modificações propostas por Oliveira-Neto permitiu a execução do ensaio de flexão rotativa em sistema de implantes com variadas configurações, produzindo resultados clinicamente relevantes. / Implant success depends on professional ability, patient biological conditions and also mechanical properties. Two fatigue tests can study implant mechanical properties: unidirectional bend-release fatigue testing and rotational fatigue testing. Advantages of rotational bending devices include faster tests that can generate relevant data and provide more realistic prediction of clinical performance. Oliveira- Neto (2011) evaluated a rotational bending device developed by Ferreira (2010), and showed its components need to be revised to ensure better implant fixation, temperature control, frequency and also enable to increase force moment. The aim of this study was fabricate and evaluate new components to Ferreiras device and it evaluate it effects in external and internal hexagon implant systems.Following groups were tested: A-external hex (EH) implants with UCLA abutment, B- EH implants with Conical Abutment, C- internal hex (HI) implants with UCLA abutment, D- IH implants with Conical Abutment. The new methodology consisted in changes on implant holder, bearing case, implant centralizer and bone material simulator (acrylic resin). Samples were spun around their long axes while being clamped into a 45o revolving collet on one end and loaded normal to their long axis on the other end. The aim was to determine the load level at which 50% of the specimens survived- and 50% fractured before 106 cycles at 16Hz. Fatigue resistance (F50) were determined using the staircase procedure. After cycling, torque of survival components were measured electronically, and all samples were analyzed by scanning electron microscopy, x-ray and digital photography. Results showed that UCLA groups have higher fatigue resistence. The IH-UCLA system showed more stable performance, with equal resistance to EH. Conical Abutment groups failure clinically better, allowing replacement of prosthetic components. The most severe damage occurred in both EH groups, with implant damages. Ferreiras device with Oliveira-Neto changes enabled to perform a rotating bending test on implant system in numerous configurations, producing clinically relevant results.

Page generated in 0.0888 seconds