• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 701
  • 110
  • 21
  • 14
  • 14
  • 14
  • 14
  • 14
  • 12
  • 11
  • 9
  • 7
  • 7
  • 6
  • 2
  • Tagged with
  • 1013
  • 499
  • 276
  • 266
  • 237
  • 224
  • 216
  • 191
  • 179
  • 137
  • 126
  • 121
  • 114
  • 113
  • 111
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Studies of dentin matrix protein 1 (DMP1) regulation and function in vivo

Lu, Yongbo. Feng, Jian Q. January 2007 (has links)
Thesis (Ph. D.)--School of Dentistry. University of Missouri--Kansas City, 2003. / "A dissertation in oral biology and molecular biology and biochemistry." Advisor: Jian Q. Feng. Typescript. Vita. Title from "catalog record" of the print edition Description based on contents viewed July 16, 2008. Includes bibliographical references (leaves 109-121). Online version of the print edition.
62

Comparison of digital and optical criteria used for detecting sound dentin a thesis submitted in partial fulfillment ... in restorative dentistry (operative) ... /

Anderson, Maxwell H. January 1982 (has links)
Thesis (M.S.)--University of Michigan, 1982.
63

The microhardness of cementum and dentin a thesis submitted in partial fulfillment ... periodontics ... /

Rautiola, Clifton A. January 1960 (has links)
Thesis (M.S.)--University of Michigan, 1960.
64

Laboratory simulation of microleakage in class 5 composite resin restorations placed without retention a thesis submitted in partial fulfillment ... restorative dentistry, operative ... /

Tay, Hock Hin. January 1988 (has links)
Thesis (M.S.)--University of Michigan, 1988.
65

Avaliação morfológica, físico-química e mecânica longitudinal de adesivo dental experimental manipulado com diferentes concentrações de água /

Esteves, Stella Renata Machado Silva. January 2018 (has links)
Orientador: Sergio Eduardo de Paiva Gonçalves / Coorientadora: Paulette Spencer / Banca: Flávia Lucisano Botelho do Amaral / Banca: Taciana Marco Ferraz Caneppele / Banca: Alessandra Cassoni Ferreira / Banca: Renata Marques de Melo Marinho / Resumo: O objetivo desse estudo foi avaliar um adesivo experimental com diferentes concentrações de água, bem como sua degradação morfológica, química, física e mecânica. A primeira etapa envolveu a manipulação do adesivo experimental contendo 45/55% de HEMA e BisGMA, 0.5% de canforoquinona, 0.5% EDMAB e 1% de DPIHP. Foram incorporadas diferentes concentrações de água a partir dessa formulação adesiva (0, 10 e 16%). Os modelos adesivos foram fotopolimerizados e as análises iniciais realizadas: Morfológicas (Estereomicroscopio e Micro-xct); Físicas (Rugosidade-Ru, Sorção-Sor, Solubilidade-Sol); Químicas (Grau de conversão-GC, Mapeamento do espécime com 16% de água e os monômeros liberados pela CLAE); Mecânicas (Resistência flexural-RF, Módulo de elasticidade-ME e Resistência a compressão-RC). Em seguida os espécimes foram divididos conforme a solução de envelhecimento (água, etanol e acetona). Foram realizadas novas análises após o envelhecimento por 2 e 84 dias. Os testes estatísticos ANOVA e Tukey (5%) foram realizados. Os resultados iniciais, sem o envelhecimento, mostraram que as diferentes concentrações de água influenciam as propriedades dos adesivos. Na análise morfológica notou-se a presença de bolhas no espécime com 16% de água. Para a Ru e GC os maiores valores foram encontrados para os espécimes com mais água em sua composição e os menores para 0%. Já nas análises mecânicas, para RF e ME os espécimes com 10% de água foram mais resistentes; e em RC os espécimes com 16% foram... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was evaluated an experimental adhesive with different water content, as well the degradation morphological, physical, chemical and mechanical. Firstly the dental adhesive was manipulated with 45/55% of HEMA and BisGMA, 0.5% of CQ, 0.5% EDMAB e 1% of DPIHP. Was added different water content (0, 10 and 16%). The adhesive model was cured and the analysis was done: Morphological (Stereomicroscope and Micro-xct); Physical (Surface Roughness), Sorption, Solubility); Chemical (Degree of convertion, Map of the pore on 16% water content sample and the released monomers- HPLC); Mechanicals (Flexural strength, Modulus of elasticity and Compressive strength). After the these analyzes, the samples were divided to each evaluation into 3 groups according to solution for performed ageing (water, ethanol and acetone). Further analyzes were performed after aging for 2 and 84 days. Statistical tests of ANOVA and Tukey (5%) were performed. Initial results, without aging, showed that the different water content influence adhesive properties. In the morphological analysis, bubbles were present on the sample with 16% water. For Ru and DC all specimens differed from each other, with the highest values for the specimens with 16% and the lowest to 0%. In the mechanical analyzes, for RF and ME the specimens with 10% water were more resistant; and in RC the specimens with 16% were less resistant. After aging it is possible notice cracks on the border of specimens 0% and 16% in the ... (Complete abstract click electronic access below) / Doutor
66

Resistência adesiva de um sistema auto-condicionante e um convencional simplificado, aplicados à dentina tratada com diferentes condicionadores

Jacques, Paula [UNESP] 14 May 2002 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:48Z (GMT). No. of bitstreams: 0 Previous issue date: 2002-05-14Bitstream added on 2014-06-13T20:36:15Z : No. of bitstreams: 1 jacques_p_me_arafo.pdf: 6578711 bytes, checksum: 7ce3c1075cc06b0164a5b42ddcb9c7d0 (MD5) / A resistência adesiva de um sistema auto-condicionante e um convencional simplificado, Clearfil SE Bond e Single Bond, respectivamente, quando aplicados à dentina superficial tratada com diferentes agentes condicionadores, foi avaliada por meio de ensaios mecânicos de microtração. Superfícies planas de dentina, obtidas removendo-se a superfície oclusal de 30 terceiros molares humanos foram polidas com lixa de granulação 600 antes da aplicação de diferentes agentes condicionadores, SE Primer, ácido fosfórico ou EDTA. O primer acidificado SE Primer foi aplicado sobre a superfície por 20 segundos, seguido de suave secagem com jatos de ar. O ácido fosfórico a 37% foi aplicado por 15 segundos, seguido de lavagem e remoção do excesso de água com papel absorvente e a solução de EDTA 0,5M pH7,2 foi aplicada por 30 segundos, também seguida de lavagem e secagem. Com exceção das superfícies que receberam a aplicação do primer acidificado, as demais foram mantidas úmidas para a posterior aplicação dos sistemas adesivos avaliados. Sobre a superfície coberta pelo sistema adesivo foi construída uma coroa em resina composta Z250 e os dentes foram mantidos em água a 37% por 24h. Após 500 ciclos térmicos em temperaturas de 5o e 55oC, cortes paralelos no sentido mesio-distal e cortes perpendiculares aos primeiros, no sentido vestibulo-lingual, permitiram a obtenção de amostras com área de secção transversal quadrangular de 1,0mm2 em número mínimo de 10 para cada dente. Cada amostra foi colada a um dispositivo especialmente desenvolvido, e este foi acoplado à uma máquina universal de testes operada à velocidade de 0,5mm/min. O lado correspondente à dentina de aproximadamente 50% das superfícies fraturadas após o ensaio mecânico foi analizado em MEV. Os resultados mostraram que o maior valor médio de resistência adesiva foi observado para a associação SE Primer... . / Microtensile bond strength of a self-etching primer and a conventional one-bottle system, Clearfi SE Bond and Single Bond, respectively, bonded to superficial dentin treated with different conditioners was investigated. Flat dentin surfaces obtained by removing the occlusal enamel with a diamond saw were ground with 600-grit SiCs under wet conditions to create the smear layer before the conditioners application. Three different dentin conditioning was performed, SE Primer, phosphoric acid and EDTA. The SE Primer was applied on dentin for 20 seconds followed by slight air-drying. Phosphoric acid (37%) was applied for 15 seconds followed by rinsing. EDTA 0.5M pH7.2 was applied for 30 seconds, also followed by water rinsing. Except for the surfaces that received the SE Primer conditioner, the surfaces were left moist by blot-drying the excess water. The adhesive systems were applied and a 5mm high composite resin (Z250) was built up covering the whole surface. After 24h of storage in water at 37oC the teeth were thermocycled for 500 cycles at preset temperatures of 5o and 55oC. The teeth were sectioned with a diamond saw, perpendicular to the adhesive interface to produce beams with 1.0mm2 of adhesive area. These specimens were then attached to a testing apparatus and a tensile load was applied by a universal machine at a crosshead speed of 0.5mm/min. After the micro-tensile bond test, the dentin side of 50% of the fractured surfaces was examined under a scanning electron microscope. The highest tensile bond strength mean was found for the association of SE Primer and Single Bond, 58.51MPa, followed by the association Clearfil SE Bond and EDTA, 47.81MPa. The remaining associations showed mean tensile bond strength statistically similar, except for the association Single Bond and EDTA, which showed the lowest... (Complete abstract, click electronic address below).
67

AnÃlise da expressÃo das mmps -2 e -9 em dentina humana sadÃa e sua interaÃÃo na interface adesiva / ANÃLISE DA ATIVIDADE PROTEOLÃTICA DAS MMPS -2 E -9 EM DENTINA HUMANA SADIA E SUA INTERAÃÃO NA INTERFACE ADESIVA

Fabianni MagalhÃes Apolonio 18 December 2014 (has links)
FundaÃÃo Cearense de Apoio ao Desenvolvimento Cientifico e TecnolÃgico / As metaloproteinases sÃo enzimas capazes de degradar o colÃgeno exposto na interface dentina/resina provocando sÃrios danos à manutenÃÃo da integridade da interface adesiva. Este estudo està dividido em trÃs capÃtulos, cujos objetivos foram: 1) Avaliar o efeito da desmineralizaÃÃo atravÃs de diferentes Ãcidos na ativaÃÃo de MMP-2 em dentina humana (CapÃtulo 1); 2) Avaliar o efeito de um sistema adesivo de passo Ãnico na ativaÃÃo de MMP-2 e -9 dentinÃria usando zimografia in situ e teste de atividade enzimÃtica; 3) Avaliar a capacidade do agente de ligaÃÃo cruzada 1-etil-3-(3-dimetilaminopropril) carbodiamida (EDC) na inibiÃÃo da atividade das MMPs em dentina (CapÃtulo 3). Como abordagens metodolÃgicas foram realizados 3 estudos in vitro com avaliaÃÃo enzimÃtica em dentina humana. ProteÃna dentinÃria foi extraÃda apÃs desmineralizaÃÃo com os Ãcidos fosfÃrico a 1% e a 10% e cÃtrico a 10% por 1, 5 e 10 min, e submetida a zimografia gelatinosa e teste de anÃlise enzimÃtica especifica, para a avaliaÃÃo da atividade de MMP-2 (CapÃtulo 1). Dentina em pÃ/blocos foi tratada com o adesivo de passo Ãnico Adper Easy Bond (3M ESPE) e a atividade de MMP-2 e -9 foi avaliada atravÃs de zimografia in situ e quantificada atravÃs do ELISA (CapÃtulo 2). Dentina em pÃ/blocos foi tratada com os sistemas adesivos Optibond FL ou Scotchbond 1XT com ou sem tratamento prÃvio com EDC. A atividade enzimÃtica foi analisada atravÃs de zimografia gelatinosa e in situ (CapÃtulo 3). A atividade de MMP-2 esteve presente em todos os grupos testados e aumentou apÃs desmineralizaÃÃo com Ãcido fosfÃrico 10% e Ãcido cÃtrico 10% (CapÃtulo 1). ApÃs tratamento com o adesivo de passo Ãnico, houve aumento da atividade enzimÃtica dentinÃria. A anÃlise in situ mostrou que a aÃÃo das MMPs està associada ao colÃgeno exposto e nÃo protegido pelos monÃmeros adesivos (CapÃtulo 2). Zimograma revelou um aumento na expressÃo de MMP-2 e -9 apÃs a exposiÃÃo aos sistemas adesivos, enquanto o uso de EDC 0.3M como prÃtratamento, inativou as gelatinases dentinÃrias (CapÃtulo 3). Pode-se concluir que tanto soluÃÃes Ãcidas (CapÃtulo 1), quanto os adesivos autocondicionantes sÃo capazes de ativar as MMPs dentinÃrias (CapÃtulo 2) e que algumas substÃncias, como o agente de ligaÃÃo cruzada EDC, sÃo capazes de inibir a ativaÃÃo destas enzimas (CapÃtulo 3). / MMPs are enzymes that can degrade exposed collagen in dentin/resin interface causing serious damage to maintaining the integrity of the adhesive interface. The present study is divided in three chapters, whose aims: 1) To evaluate the effect of demineralization by different acid solutions in MMP-2 activation on human dentin (Chapter 1); 2) To evaluate the effect of a one-step adhesive system on dentinal MMP-2 and -9 activation using in situ zymography and an enzymatic activity assay (Chapter 2); and 3) To evaluate the ability of MMPs inhibition by 1-ethyl-3-(3- dimethylaminopropryl) carbodiimide (EDC) EDC cross-linker on dentin (Chapter 3). As for the methodology approaches, 3 in vitro studies were performed to evaluate enzymatic expression of human dentin. Dentin protein was extracted after demineralization by 1% phosphoric acid, 10% phosphoric acid and 10% citric acid for 1, 5 and 10 minutes, and subjected to gelatin zymographic and activity assay (Chapter 1). Dentin powder/slabs were treated with one-step adhesive Adper Easy Bond (3M ESPE) and MMP-2 and -9 activities were evaluated using in situ zymography and quantified by means of an specific enzymatic assay (Chapter 2). Dentin powder/slabs were treated with one of those adhesive systems: Optibond FL or Scotchbond 1XT with or without pre-treatment using EDC. The enzymatic activity was analyzed using gelatin zymography and in situ zymography (Chapter 3). MMP-2 activity was present in all tested groups and increased after demineralization by 10% phosphoric acid and 10% citric acid (Chapter 1). After treated with one-step adhesive, enzymatic activity increased. In situ evaluation showed that MMPs action is associated with the exposed and unprotected collagen promoted by adhesive monomers (Chapter 2). Zymograms revealed increased expression of dentin endogenous MMP-2 and -9 after adhesives systems application, while the use of 0.3M EDC as a primer, inactivated dentin gelatinizes (Chapter 3). It can be concluded that both acid solutions (Chapter 1) and self-etch adhesives (Chapter 2) are able to activate dentin MMPs and that solutions like EDC cross-linker can inhibit the activation of those enzymes (Chapter 3).
68

Avaliação in vitro dos efeitos da aplicação de sistemas adesivos, do oxalato de potássio, ou a combinação de ambos, na permeabilidade dentinária / Effects of a potassium oxalate gel/adhesive agent combined application on dentin permeability: an in vitro study

Safira Marques de Andrade e Silva 17 June 2005 (has links)
A tendência atual de simplificação de sistemas adesivos transformou-os em polímeros altamente hidrofílicos e prontamente susceptíveis à permeação de água através de sua estrutura. Estudos recentes têm demonstrado que os sistemas adesivos simplificados se comportam como membranas semipermeáveis, permitindo o movimento de fluidos através da sua estrutura. Soluções a base de oxalato de potássio são efetivos agentes de redução da condutividade hidráulica dentinária. Quando são aplicados na dentina após o condicionamento ácido, podem ser utilizados em associação com os sistemas adesivos sem o comprometimento da adesão. Este trabalho objetivou avaliar os efeitos dos sistemas adesivos AdheSE, One Up Bond F e Single Bond, associados ou não a uma solução a base de oxalato de potássio, na condutividade hidráulica da dentina. Foram realizados preparos de coroas totais em terceiros molares humanos que tiveram suas raízes secionadas e a polpa coronária removida. Os segmentos coronários obtidos foram conectados ao ?Medidor de Fluxo? (Flodec?System, De marco Engineering, Switzerland). A condutividade hidráulica dos espécimes foi mensurada antes e após a aplicação dos sistemas adesivos Single Bond -3M ESPE, One UP Bond F -Tokuyama Inc, AdheSe- Ivoclar- Vivadent. Os adesivos foram aplicados seguindo as recomendações do fabricante (grupos SBF, ADF e OBF), de forma experimental (grupos ADE e OBE), e em combinação com uma solução a base de oxalato de potássio (grupos SBO, ADO e OBO). Cada espécime teve seu valor de permeabilidade original ( smear layer) e máxima (após condicionamento ácido) medidos anteriormente, os quais serviram como parâmetros para o cálculo das respectivas alterações frente aos tratamentos, expressas em porcentagem. Após a determinação da condutividade hidráulica, os preparos foram moldados para obtenção de réplicas em resina, as quais foram examinadas em MEV (JEOL 2800, Japão) para qualificar a permeação de fluido através do adesivo. A Análise de variância a 2 critérios mostrou que apesar dos procedimentos adesivos causarem uma redução significante (p< 0.05) na condutividade hidráulica da dentina condicionada, nenhum foi capaz de eliminar completamente a passagem de fluidos através do adesivo polimerizado. Para os três adesivos testados, o tratamento com o oxalato de potássio foi o tratamento mais eficaz na redução da permeabilidade dentinária e esta diferença foi estatisticamente significante quando comparada aos outros tratamentos (p<0,05). Não houve diferença entre os três sistemas adesivos estudados com relação à redução da permeabilidade dentinária (p> 0,05). A análise das réplicas em MEV mostrou que mesmo após a polimerização do adesivo, a transudação de fluidos pôde ser identificada na superfície de todas réplicas examinadas. Nenhum dos sistemas adesivos testados foi capaz de eliminar a permeação de fluidos através da dentina, contudo a associação destes adesivos com uma solução a base de oxalato de potássio reduziu de forma significante a permeabilidade dentinária. / There is an ongoing trend to move away from classical multi-component bonding systems toward simplified adhesives. An immediate consequence of adhesive simplification is the intrinsic permeability to water that result from their increase in hydrophilicity. Current studies have demonstrated that single-step adhesives may act as semi-permeable membranes that allow water diffusion through its structure. Oxalate desensitizers are effective in reducing the hydraulic conductance of dentin. When oxalates are used after acid- etching they do not interfere with subsequent resin bonding. The objective of this study was to test the effects of adhesives systems with or without the application of an oxalate desensitizer on dentin permeability. Crown preparations were made from human extracted teeth. After the roots were sectioned and the coronal pulp removed, the crown segments were connected to an automatic flow-recording device (Flodec-System, De Marco Engineering, Switzerland). Fluid conductance was measured before and after the bonding procedures with the adhesives Single Bond -3M ESPE, One UP Bond F -Tokuyama Inc and AdheSe- Ivoclar Vivadent. Specimens were prepared and tested after the surface had been bonded according to manufacturer?s instructions (SBF,ADF and OBF groups) , in a experimental way (ADE and OBE groups) or integrating with a oxalate desensitizer gel (SBO, ADO and OBO groups). For each specimen, fluid flow across the smear-layer and bonded dentin was expressed as a percentage of acidetched dentin, which was assigned a value of 100% flow rate. After the hydraulic conductance measures, impressions were taken from the crown segments and epoxy resin replicas were produced for SEM examination. Two-Way ANOVA reveled that the adhesive systems reduced dentin permeability significantly (p< 0.05) compared to acid etched dentin, but no bonding system was able to eliminate the fluid flow though dentin. For the three bonding systems tested, treating the acid-etched dentin with potassium oxalate prior to the application of the adhesive was the most effective in reducing the hydraulic conductance of the specimens, and this difference was significant (p< 0.05) when comparing to the other treatments. There were no significant differences among the adhesives in their ability to reduce dentin permeability (p> 0.05). SEM micrographs of resin replicas showed that transudation of dentinal fluid droplets could be identified on the surfaces of all replicas examined.
69

Avaliação in vitro da condutibilidade hidráulica da dentina após a irradiação de diferentes parâmetros de laser associados ou não com verniz fluoretado / In vitro evaluation of dentin hydraulic conductance after irradiation with different LASER parameters, associated or not with a fluoride varnish

Fabio Antonio Piola Rizzante 24 February 2015 (has links)
Os tratamentos que visam a remissão dos sintomas provocados pela hipersensibilidade dentinária são baseados na obliteração física dos túbulos dentinários com o objetivo de reduzir a condutibilidade hidráulica da dentina. Nesse contexto, diversos tratamentos têm sido avaliados, entre eles, a irradiação da superfície dentinária com laser. O objetivo do presente estudo foi avaliar a condutibilidade hidráulica da dentina radicular bovina, após irradiação com um laser de diodo (980nm), associado ou não com um verniz fluoretado. Sessenta espécimes de dentina radicular bovina com dimensões 5,5 X 5,5 X 1mm foram divididos em 6 grupos (n=10): Grupos 1, 3 e 5 (laser de diodo com 0,5; 0,7 e 1W respectivamente); Grupos 2, 4 e 6 (associação entre verniz fluoretado e laser de diodo com 0,5; 0,7 e 1W). A condutibilidade hidráulica da dentina, avaliada em FLODEC, foi analisada em 4 momentos: após criação da smear layer (permeabilidade mínima), após condicionamento com gel de ácido fosfórico a 37% (permeabilidade máxima), após os tratamentos propostos e após o desafio ácido com ácido cítrico a 6%. Os dados obtidos foram avaliados pela ANOVA a 2 critérios e teste de Tukey para comparação entre os diferentes grupos e ANOVA 1 critério de medidas repetidas e teste de Tukey para comparação entre as diferentes leituras dentro de cada grupo, sempre com p<0,05%. As análises demonstraram um melhor resultado conforme o aumento da potência de irradiação, principalmente se esta for associada à aplicação do verniz fluoretado, garantindo uma melhor estabilidade dos tratamentos, mesmo após o desafio ácido. Após essa última etapa, os espécimes foram avaliados quanto à composição mineral em EDX, apresentando como principais alterações nos grupos irradiados com laser, um aumento na proporção de ions Cálcio e Fósforo, associada à redução dos íons Carbono e Oxigênio. Dessa forma, a irradiação da dentina exposta com laser de diodo promoveu redução significante na condutibilidade hidráulica, principalmente com densidades de energia mais elevadas e quando associado ao verniz fluoretado. / The dentin hypersensitivity treatments are based on the physical obliteration of dentinal tubules in order to reduce the dentin hydraulic conductance. Hence, many treatments have been evaluated, such as the dentin surface laser irradiation. The aim of the present study was to evaluate the bovine root dentin hydraulic conductance after 980nm diode laser irradiation, associated or not with a fluoride varnish. Sixty bovine root dentin specimens were divided into six groups (n=10): Groups 1, 3 and 5 (0.5, 0.7 and 1W diode laser respectively); Groups 2, 4 and 6 (association between fluoride varnish application and 0.5, 0.7 and 1W diode laser irradiation). The dentin hydraulic conductance was evaluated at 4 moments, with FLODEC: after smear layer (minimum permeability), after 37% phosphoric acid gel etching (maximum permeability), after the treatments and after 6% citric acid challenge. The analysis demonstrated a better result with increased irradiation power, especially if the diode laser irradiation was associated with the application of a fluoride varnish, ensuring a greater treatment stability, even after acid challenge. After the citric acid challenge, the specimens were evaluated for mineral composition in EDX. The irradiated groups showed, as major changes after laser irradiation, an increase in the proportion of calcium and phosphorus ions, associated with the reduction of carbon and oxygen ions. In conclusion, the laser irradiation of the exposed dentin promoted a significant reduction in hydraulic conductance, mainly with higher energy densities and when combined with a fluoride varnish.
70

Fluid transport across bonded dentin interfaces

Yiu, Kar-yung, Cynthia., 姚嘉榕. January 2006 (has links)
published_or_final_version / abstract / Dentistry / Doctoral / Doctor of Philosophy

Page generated in 0.0885 seconds