• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 338
  • 7
  • 7
  • 7
  • 7
  • 6
  • 4
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 351
  • 320
  • 216
  • 168
  • 168
  • 140
  • 97
  • 84
  • 75
  • 72
  • 61
  • 60
  • 60
  • 58
  • 41
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
151

Influência do método de preparo cavitário, alta rotação e laser de Er:YAG, sobre a espessura da camada híbrida de diferentes sistemas adesivos, com diferentes filosofias adesivas / Influence of cavity preparation method, high speed turbine and Er:YAG laser, on hybrid layer thickness of different adhesive systems

Marcos de Oliveira Barceleiro 11 October 2006 (has links)
O objetivo deste estudo foi promover uma comparação entre as espessuras de camadas híbridas formadas entre os sistemas adesivos Scotchbond Multi-Uso Plus, Single Bond 2, Prime & Bond 2.1 e Xeno III, e a superfície dentinária, preparada com dois métodos de preparo cavitário, a ponta diamantada montada em turbina de alta rotação, e o laser de Er:YAG, utilizado com dois parâmetros de energia (200 e 400 mJ) e dois parâmetros de freqüência (4 e 6 Hz). Para a realização deste experimento, foram realizados tratamentos superficiais com os dois métodos descritos em fragmentos de dentina superficial aplainada, retirados de vinte terceiros molares humanos recém-extraídos, seguido de preparo da dentina com os sistemas adesivos. Após a aplicação e fotoativação de uma camada de compósito sobre a dentina preparada, os corpos de prova foram cortados, polidos e preparados para visualização em MEV, meio pelo qual foram realizadas cinco medidas da espessura da camada híbrida formada em cada corpo de prova. Os resultados obtidos foram tratados estatisticamente por ANOVA e teste de Student-Newnan-Keuls, em um nível de significância de 95%, e por Kruskal Wallis e Mann Whitney, também em um nível de significância de 95%, através do programa SPSS for Windows release 5.0. A análise foi realizada levando-se em consideração dois fatores de estudo, a presença ou não de camada híbrida e a espessura da camada híbrida. Em relação ao fator espessura da camada híbrida, quando se avaliou o tipo de preparo realizado, a análise estatística por ANOVA e Student-Newman-Keuls levou a formação de quatro grupos homogêneos, sendo Grupo I (ponta diamantada) > Grupo II (Laser 200 mJ / 4 Hz) = Grupo III (Laser 200 mJ / 6 Hz) > Grupo IV (Laser 400 mJ / 4 Hz) > Grupo V (Laser 400 mJ / 6 Hz). Quando se avaliou o tipo de sistema adesivo utilizado, não se encontrou diferença estatisticamente significante. Em relação ao fator presença de camada híbrida, quando se avaliou o tipo de preparo realizado, a análise estatística por Kruskal Wallis e Mann Whitney levou a formação de três grupos homogêneos (Grupo I _ Grupo II = Grupo III = Grupo IV _ Grupo V). Quando se avaliou o tipo de sistema adesivo utilizado, não se encontrou diferença estatisticamente significante. Quando se realizou o cruzamento tipo de preparo x sistema adesivo, a análise estatística mostrou a formação de sete grupos distintos. Pela análise dos resultados obtidos neste estudo in vitro, foi possível concluir que em dentina preparada com ponta diamantada em alta rotação, os quatro sistemas adesivos testados formaram camadas híbridas de formato regular e presentes de forma constante, com espessura média de 2,90 1,71 m, e em dentina preparada com laser de Er:YAG, os quatro sistemas adesivos testados formaram camadas híbridas de formato irregular e presentes de forma intermitente, com espessura média variando entre 0,41 1,00 m e 2,06 2,49 m. Além disso, concluiu-se que o laser de Er:YAG com os parâmetros testados influencia negativamente a formação da camada híbrida, e que os métodos de preparo cavitário influenciam na espessura da camada híbrida. / The objective of this study was to compare the thickness of the hybrid layer formed using Scotchbond Multipurpose Plus, Single Bond 2, Prime & Bond 2.1 and Xeno III on dentine surface, prepared with a diamond bur in a high speed handpiece, or prepared with an Er:YAG laser, used with two parameters of pulse energy (200 and 400 mJ) and two parameters of frequency (4 and 6 Hz). Flat dentine surfaces obtained from twenty third molars human teeth were treated with the two methods, and then were prepared with the dentine adhesive systems, according to manufacturers instructions. After a layer of composite was applied, specimens were sectioned, flattened, polished and prepared for Scanning Electronic Microscopy observation. Five different measurements of hybrid layer thickness were obtained along the bonded surface in each specimen. Results were statistically analyzed using analysis of variance and Student-Newman-Keuls tests (p ≤ 0.05), and using Kruskal Wallis and Mann Whitney tests (p ≤ 0.05). The statistical analysis was made considering two observations parameters, the presence of the hybrid layer, and its thickness. When analyzing the hybrid layer thickness, and comparing the cavity preparation method, four groups were formed, Group I (diamond bur) > Group II (Laser 200 mJ / 4 Hz) = Group III (Laser 200 mJ / 6 Hz) > Group IV (Laser 400 mJ / 4 Hz) > Group V (Laser 400 mJ / 6 Hz). When comparing the dentine adhesive systems, it was not found any statistically significant difference. When analyzing the presence of hybrid layer, and comparing the cavity preparation method, three groups were formed (Group I ≠ Group II = Group III = Group IV ≠ Group V). When comparing the dentine adhesive systems, it was not found any statistically significant difference. When analyzing the hybrid layer thickness, and comparing the cavity preparation method x the dentine adhesive systems, it was found seven different groups. These results showed that the four tested dentine adhesive systems produce a 2.90 1.71 μm hybrid layer in dentine prepared with diamond bur. This hybrid layer was regular and constantly found. In the laser groups, the dentine adhesive systems produced hybrid layers ranging from 0.41 1.00 μm to 2.06 2.49 μm, which were very irregular and were not found constantly. It was also concluded that Er:YAG laser with the parameters used in this experiment, is a negative influence to the hybrid layer formation, and that cavity preparation methods do influence the hybrid layer formation.
152

Análise molecular vibracional da interface adesivo-dentina após aplicação de múltiplas camadas de sistemas adesivos convencionais de dois passos / Dentine-adhesive molecular vibrational analysis of multi-layer applications of one step etch and rinse adhesive systems

Marcelo José Braga Pinhão 28 February 2008 (has links)
O propósito do presente estudo foi analisar o efeito da aplicação de múltiplas camadas consecutivas de dois sistemas adesivos convencionais de dois passos na difusão resinosa e padrão de distribuição dos componentes monoméricos resinosos. Dezesseis terceiros molares humanos hígidos foram tratados com os sistemas adesivos convencionais de dois passos de acordo com as instruções dos fabricantes ou com aplicações em múltiplas camadas consecutivas. Os espécimes foram seccionados paralelamente aos túbulos dentinários e as superfícies submetidas ao polimento com lixas 600, 1200, 1800, 2000 e 4000. Os espectros Raman foram coletados ao longo de uma linha perpendicular a interface adesivo-resina em intervalos de 1 ou 2 m. As medidas de difusão da resina adesiva e distribuição dos componentes monomériccos foram avaliadas pelos picos Raman de 1113 cm-1, 1609 cm-1 e 1454 cm-1. O gradiente de desmineralização usado na determinação da região de hibridização foi avaliado pelo pico de 960 cm-1 da apatita. De acordo com os resultados obtidos, a aplicação de múltiplas camadas apresentou uma tendência de homogeneização dos componentes poliméricos, dependente da composição química da resina adesiva. / The present study analyzed the effect of multiple consecutive adhesive coatings on the pattern of resin diffusion and distribution of monomer components through demineralised dentin after application of two total-etch adhesives. Resin bonded dentin specimens were prepared using two total-etch adhesives (Prime&Bond NT2.1 and Adper Single Bond). The specimens were sectioned parallel to dentinal tubules and the surfaces were polished using 600, 1200, 1800, 2000 and 4000 silicon-carbide papers. Raman spectra were recorded along a line perpendicular to the dentin-resin interface in steps of 1 or 2 m. The measurements of resin diffusion and distribution of monomer components were made on a relative basis by comparing the bands 1113, 1609 and 1454 cm-1. The gradient of dentin demineralization, designed to 960 cm-1, was used to determine the extent of hybridization. From the results of the present study the application of multiple coatings of adhesive showed a trend to produce a homogeneous hybrid layer.
153

Avaliação do efeito do plasma não térmico na resistência adesiva à dentina supericial e profunda / Effect of non-thermal plasma on bond strength to superficial and deep dentin

Franco, Lucas Teixeira [UNESP] 18 January 2016 (has links)
Submitted by LUCAS TEIXEIRA FRANCO null (teixeira_90@hotmail.com) on 2016-02-03T22:56:21Z No. of bitstreams: 1 Dissertação final.pdf: 2325492 bytes, checksum: 36f8ac7caa1da3a9ee584908b80cac74 (MD5) / Approved for entry into archive by Ana Paula Grisoto (grisotoana@reitoria.unesp.br) on 2016-02-05T11:58:03Z (GMT) No. of bitstreams: 1 franco_lt_me_sjc.pdf: 2325492 bytes, checksum: 36f8ac7caa1da3a9ee584908b80cac74 (MD5) / Made available in DSpace on 2016-02-05T11:58:03Z (GMT). No. of bitstreams: 1 franco_lt_me_sjc.pdf: 2325492 bytes, checksum: 36f8ac7caa1da3a9ee584908b80cac74 (MD5) Previous issue date: 2016-01-18 / O tratamento com plasma não térmico pode modificar a superfície da dentina e melhorar a ligação entre os dentes e resinas compostas. O objetivo deste estudo foi avaliar a influência do tratamento do plasma não térmico (PNT) na resistência adesiva de um sistema adesivo autocondicionante aplicado em diferentes espessuras de dentina humana, bem como observar mudanças na micromorfologia das interfaces dentina/resina em MEV. Molares humanos foram divididos em dois grupos (n = 30) de acordo com a espessura da camada de dentina: superficial (S) (2 mm de espessura) e profunda (P) (1 mm de espessura). Cada grupo foi dividido em três subgrupos (n = 10) de acordo com o tratamento de superfície da dentina: grupo SPA (2 mm dentina + plasma + adesivo); Grupo SAP (2 mm dentina + adesivo + plasma); Grupo SA (2mm de dentina + adesivo); PPA (1 mm dentina + plasma + adesivo); Grupo PAP (1 mm dentina + adesivo + plasma) e grupo PA (1 mm dentina + adesivo). Foi confeccionada uma restauração em resina composta e as amostras armazenadas (48 h). Palitos de dentina/resina com área adesiva de aproximadamente 1 mm² foram obtidos e submetidos ao teste de microtração. O padrão de fraturas foi analisado por microscopia óptica. Os dados de resistência foram analisados pelos testes estatísticos ANOVA dois fatores e Tukey (5%). As análises das interfaces adesivas em MEV foram realizadas em amostras selecionadas. Os resultados mostraram uma diferença significativa na resistência adesiva entre a dentina superficial e profunda; independentemente do tratamento de superfície, a dentina superficial apresentou maiores valores de resistência adesiva. Entre os grupos tratados com e sem plasma, a resistência adesiva foi maior quando o plasma foi aplicado na superfície da dentina; no entanto a aplicação de plasma antes ou depois do o adesivo não foi estatisticamente diferente. O PNT aumentou a resistência adesiva da dentina humana S e P. / Treatment with non-thermal plasma can modify dentin surface and improve bond between teeth and composite resin. The objective of this study was to evaluate the influence of non-thermal plasma (NTP) treatment on dentin bond strength of a self-etching adhesive system to different thicknesses of human dentin as well as to observe SEM micromorphology changes of the resin/dentin interfaces. Human molars were divided into two groups (n = 30) according to dentin layer thickness: superficial (S) (2 mm thick) and deep (D) (1 mm thick). Each group was divided into three subgroups (n = 10) according to dentin surface treatment: SPA group (2 mm dentin + plasma + adhesive); SAP group (2 mm dentin + adhesive + plasma); Group SA (2 mm dentin + adhesive); PPA (1 mm dentin + plasma + adhesive); PAP group (1 mm dentin + adhesive + plasma) and PA group (1 mm dentin + adhesive). A composite resin restoration was built up and specimens stored (48 h). Teeth sticks with adhesive area of approximately 1 mm² were obtained and submitted to microtensile test. The pattern of fractures was analyzed with optical microscopy. Bond strength data was analyzed by two-way ANOVA and Tukey (5%) statistical tests. Resin/dentin interfaces SEM analysis was conducted on selected specimens. The results showed a significant difference in bond strength between superficial and deep dentin; regardless surface treatment superficial dentin showed higher bond strength. Among the groups treated with and without plasma, bond strength was higher when plasma was applied on dentin surface; however plasma application before or after the adhesive was not statistically different. NTP increased the bond strength of S and D human dentin.
154

Análise da interface adesiva entre pinos de fibra de vidro e dentina intrarradicular submetida à irrigação com diferentes agentes condicionantes

Suzuki, Thaís Yumi Umeda [UNESP] 02 September 2015 (has links) (PDF)
Made available in DSpace on 2016-02-05T18:30:15Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-09-02. Added 1 bitstream(s) on 2016-02-05T18:34:25Z : No. of bitstreams: 1 000858044.pdf: 2235290 bytes, checksum: 51b5ad1697c21ed4ef39b0820eb09e2b (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O propósito deste estudo foi avaliar a interação das soluções irrigantes e tipos de cimentos resinosos na cimentação de pinos de fibra de vidro nos diferentes terços da dentina intrarradicular, através do teste de resistência de união, avaliação das propriedades mecânicas e capacidade de selamento da interface adesiva. Noventa dentes pré-molares humanos unirradiculares foram utilizados neste estudo. Após obturação endodôntica e preparo mecânico dos condutos radiculares, os dentes foram divididos em 5 grupos de acordo com os agentes condicionantes (água destilada, hipoclorito de sódio 5,25%, ácido poliacrílico 25%, clorexidina 2%, dispersão de nanopartículas de prata à 23 ppm) e subdivididos em 3 grupos experimentais (n=6), de acordo com a técnica adesiva adotada para cimentação de pinos de fibra de vidro: Grupo SBU: adesivo autocondicionante ScotchbondTM Universal + cimento resinoso convencional RelyX ARC; Grupo U200: cimento resinoso autoadesivo RelyX U200; Grupo MCE: cimento resinoso autoadesivo Maxcem Elite. As propriedades mecânicas de dureza e módulo de elasticidade das estruturas da interface adesiva (cimento resinoso e dentina subjacente) foram mensuradas em ultramicrodurômetro digital DUH-211 (Shimadzu), sob carga de 5mN nos diferentes terços da dentina intrarradicular (cervical, médio e apical). A resistência de união foi mensurada pelo teste de push-out em máquina de ensaio universal (Emic DL 3000). A capacidade de selamento foi quantificada através de um sistema de infiltração de fluido (Flodec) durante 5 minutos. Os dados de resistência de união, propriedades mecânicas e capacidade de selamento foram submetidos a testes estatísticos de normalidade e analisados pela ANOVA para medidas repetidas e teste de Fisher (α = 0,05). Os resultados mostraram que as propriedades mecânicas de dureza... / The purpose of this study was to evaluate the interaction of conditioning agents and resin cements in the luting procedure of glass fiber posts in different thirds of intra-root dentin, through the bond strength test, mechanical properties and sealing ability of the adhesive interface. Ninety single-rooted premolares human teeth were used in this study. After endodontic filling and mechanical preparation of root canal, teeth were divided into five groups according to the conditioning agents (distilled water, 5.25% sodium hypochlorite, 25% polyacrylic acid, 2% chlorhexidine and 23 ppm silver nanoparticles dispersion). Three adhesive cementation technique were adopted: Group 1: ScotchbondTM Universal self-etching adhesive + RelyX ARC resin cement, Group 2: RelyX U200 self-adhesive resin cement, Group 3: Maxcem Elite self-adhesive resin cement. The mechanical properties (Martens hardness and elastic modulus) of the adhesive interface structures (resin cement and underlying dentin) were measured in a DUH-211 digital ultra-microhardness tester (Shimadzu), under load of 5mN in different areas of intra-root dentin (cervical, middle and apical). Push-out bond strength was measured in a universal testing machine (Emic DL 3000). Sealing ability was quantified with a fluid-filtration system (Flodec) during 5 min was immediately measured. The data of bond strength and mechanical properties were subjected to statistical tests of normality and analyzed by ANOVA for repeated measures and Fisher's test (α=0.05). The results showed that the mechanical properties of Martens hardness and elastic modulus of resin cements and the underlying dentine can be influenced by conditioning agents, as well as the depth of intraradicular dentin. The same phenomenon was observed in the push-out bond strength test. The 23ppm silver nanoparticle dispersion... / FAPESP: 12/12771-9
155

Resistência de união de cimentos resinosos, convencional e autoadesivo, em substratos dentinários normal e hipermineralizado artificalmente / Bond strength of resin, conventional and self-adhesive cements, under normal dentin substrates and sclerotic artificially

Tavares, Maria Tereza Gomes [UNESP] 21 March 2016 (has links)
Submitted by MARIA TEREZA GOMES TAVARES null (mariatereza_t@hotmail.com) on 2016-04-04T12:44:42Z No. of bitstreams: 1 Dissertação Maria Tereza.pdf: 2059134 bytes, checksum: 54c1a762e9d937d867d45018734397ae (MD5) / Approved for entry into archive by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br) on 2016-04-05T18:59:26Z (GMT) No. of bitstreams: 1 tavares_mtg_me_arafo.pdf: 2059134 bytes, checksum: 54c1a762e9d937d867d45018734397ae (MD5) / Made available in DSpace on 2016-04-05T18:59:27Z (GMT). No. of bitstreams: 1 tavares_mtg_me_arafo.pdf: 2059134 bytes, checksum: 54c1a762e9d937d867d45018734397ae (MD5) Previous issue date: 2016-03-21 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste trabalho foi avaliar a resistência de união de cimentos resinosos, convencional e autoadesivo, em um substrato dentinário normal e hipermineralizado artificialmente. Sessenta e seis (N=67) molares humanos hígidos, doados pelo Banco de Dentes da Faculdade de Odontologia de Araraquara, foram selecionados e divididos aleatoriamente, de acordo com o tipo de substrato dentinário: normal (n= 33) e hipermineralizado artificialmente (n=34). Em seguida o grupo de substrato dentinário normal foi subdividido em N-ARC, N-U200 e N-AC+U200 de acordo com o tipo de protocolo de cimentação: RelyX™ ARC, RelyX™ U200 e condicionamento adicional com ácido fosfórico 37% por 15” + RelyX™ U200; e o de substrato hipermineralizado artificialmente foi subdividido em H-ARC, H-U200 e H-AC+U200 seguindo o mesmo protocolo de cimentação. Um (n=1) espécime de cada grupo foi submetido a análise de microscopia eletrônica de varredura (MEV). As cimentações dos cilindros foram realizadas com a ajuda de uma matriz bipartida de teflon. Após período de armazenagem em ambiente úmido por 24 horas a 37°C, os espécimes foram adaptados a um dispositivo para o teste de resistência de união ao microcisalhamento. A análise estatística utilizada foi Two-way ANOVA/Tukey. Não foram encontradas diferença estatística entre os substratos dentinários e os protocolos de cimentação. O cimento resinoso RelyX ARC apresentou maiores valores de resistência de união (N-ARC=77,60 e H-ARC=68,40), independente do substrato. O padrão de fratura predominante foi do tipo adesiva. As imagens de microscopia mostraram que os cimento autoadesivo RelyX U200 é incapaz de formar camada híbrida. Conclui-se que o cimento autoadesivo apresenta resistência de união ao microcisalhamento semelhante ao cimento convencional, independente do substrato dentinário ser normal ou hipermineralizado artificialmente. / The objective of this study was to evaluate the bond strength of resin, conventional and self-adhesive cements, in a normal dentin and sclerotic artificially. Sixty-six (N = 66) human molars, donated by Teeth Bank of Araraquara Dental School, were selected and randomly divided according to the type of dentin: normal (n = 33) and sclerotic artificially (n = 33). Then normal dentin group was subdivided into N ARC, N-U200 and N-AC + U200 in accordance with the type of cementing protocol: RelyX ™ ARC RelyX ™ U200 and additional conditioning with phosphoric acid 37% by 15 "+ RelyX ™ U200; and the sclerotic substrate was artificially subdivided into M-ARC M-H U200 and U200 AC + following the same protocol cementing. A (n = 1) specimen from each group was subjected to analysis of scanning electron microscopy (SEM). The cementing was carried out with the aid of a metallic mold Teflon. After the storage period in a humid environment for 24 hours at 37 ° C, the specimens were adapted to a device for testing the bond strength of the microshear. The statistical analysis used was Two-way ANOVA / Tukey. There were no statistical difference between the dentinal substrates and cementation protocols. The resin cement RelyX ARC showed higher bond strength values (N = 77.60 ARC and ARC-H = 68.40), regardless of the substrate. The pattern of prevalent fracture was of adhesive type of cement and dentin. The microscopy images showed that the selfadhesive cement RelyX U200 is unable to form hybrid layer. It follows that the selfadhesive cement bond strength has to microshear similar to conventional cement, independent of the substrate normal or sclerotic dentin be artificially.
156

Resistência adesiva e citotoxicidade In vitro de diferentes gerações de adesivos dentinários

Silva, João Maurício Ferraz da [UNESP] 23 July 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:25Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-07-23Bitstream added on 2014-06-13T20:01:53Z : No. of bitstreams: 1 silva_jmf_dr_sjc.pdf: 673718 bytes, checksum: a9a6928557da03c914d3af794e3bd430 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo do estudo foi avaliar quatro diferentes sistemas adesivos (Multi- Purpose, Single Bond, SE Plus e Easy Bond – 3M ESPE) no que se refere à resistência adesiva ao microcisalhamento na dentina bovina. Além de avaliar a citotoxicidade desses novos sistemas adesivos por meio do teste de barrerira dentinária e ensaio de MTT em fibroblastos pulpares bovinos. Para o teste de microcisalhamento 80 dentes bovinos tiveram suas raízes seccionadas, foram embutidos em resina acrílica e tiveram a superfície vestibular desgastada expondo-se a dentina, sendo que em 40 dentes a espessura de dentina remanescente foi de 500μm e nos outros 40 de 200μm. Os cdp receberam então o procedimento adesivo de acordo com as instruções do fabricante e com auxílio de uma matriz metálica, cilindros de resina (Z 250 – 3M ESPE) de 0,8 mm de diâmetro e 1mm de altura foram construídos. Após 24h os cdp foram então submetidos ao ensaio de microcisalhamento. Para avaliar a citotoxicidade foi usado o teste de barreira dentinária. Células pulpares bovinas transformadas foram cultivadas em redes de nylon por 2 semanas, obtendo-se uma cultura de 3 dimensões. Essas culturas celulares foram separadas dos materiais testados por fatias de dentina de 500 e 200μm em um dispositivo de perfusão celular. Os materiais foram aplicados na porção cavitária do dispositivo de acordo com as instruções do fabricante, e um material de moldagem a base de silicona (President, Coltene) foi usado como controle negativo (100% de viabilidade celular). Após 24 h de periodo de exposição, a viabilidade celular foi mensurada fotometricamente (teste MTT). Por meio de estatística descritiva verificou-se que a melhor eficiência adesiva foi apresentada pelo adesivo auto-condicionante de um passo só, Easy Bond (21,06 MPa - 200μm; 27,01 MPa- 500μm) seguido pelo Single Bond (15,64 MPa - 200μm; 23,45 MPa- 500μm), SE Plus... / The aim of this study was to evaluate four different adhesive systems (Multi- Purpose, Single Bond, SE Bond Plus and Easy - 3M ESPE) with regard to microshear bond strength to bovine dentin. In addition evaluate the cytotoxicity of these new adhesive systems by means of a dentin barrier test. To test microshear 80 bovine teeth had their roots sectioned and were embedded in acrylic resin. The buccal surface had been worn to expose the dentin, in 40 teeth the remaining dentin thickness was 500μm and 200μm in the other 40. The specimes received the adhesive procedure according to the manufacturer's instructions and with the aid of a metal matrix, cylinders of resin (Z 250 - 3M ESPE) from 0.8 mm in diameter and 1mm in height were built. After 24h the specimes were then subjected to the microshear testing To evaluate the cytotoxicity, a dentin barrier test was used. SV3NeoB transfected bovine pulp derived cells were grown on nylon meshes for 2 weeks achieving a 3-dimensional cell culture as described. These cell cultures were separated from the test materials by dentin slices of 200 or 500μm thickness in a cell cultures perfusion chamber. The materials were applied into the cavity part of the device according to manufacturer’s instruction, and a silicon impression material (President, Coltene) served as a negative control material (100% cell viability). After a 24h exposure period, cell viability was measured photometrically (MTT test). Median values (plus 25% and 75% percentiles) of cell viability measurements (n=10) were statistically analyzed (Mann-Whitney test, = 0.05). Descriptive statistics found that the best bonding performance was presented by the single step adhesive Easy Bond (21.06 - 200μm, 27.01 - 500μm) followed by Single Bond (15.64 - 200μm; 23.45 - 500μm), SE Plus (18.23 - 200μm; 20.07 - 500μm) and Multi Purpose (15.24 - 200μm; 17.99 - 500μm). Moreover, it was... (Complete abstract click electronic access below)
157

Efeito da ciclagem de ph erosiva nas propriedades mecânicas da dentina utilizando diferentes materiais restauradores

Guedes, Ana Paula Albuquerque [UNESP] 26 July 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:25Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-07-26Bitstream added on 2014-06-13T20:41:41Z : No. of bitstreams: 1 000737081.pdf: 1574523 bytes, checksum: 5bd18c418b9c0819dc40248db7d21062 (MD5) / O objetivo deste estudo in vitro foi avaliar o efeito da ciclagem de pH erosiva com soluções que simulam a erosão dental, provenientes de fatores extrínsecos ou intrínsecos, na dureza e módulo de elasticidade da dentina restaurada com materiais restauradores contendo fluoretos. Quarenta e cinco blocos de dentina medindo 6 x 6 mm foram restaurados com cinco materiais restauradores: sistema adesivo de condicionamento total Adper Single Bond 2 + resina composta Filtek Z250; sistema adesivo autocondicionante One Up Bond F + resina composta Filtek Z250; sistema adesivo autocondicionante Clearfil SE Protect + resina composta Filtek Z250; cimento de ionômero de vidro convencional Riva Self Cure; cimento de ionômero de vidro resinoso Riva Light Cure. Mensurações da dureza Martens e módulo de elasticidade da dentina subjacente à interface de união (10μm, 30μm, 50μm e 70μm) foram realizadas em ultramicrodurômetro digital antes e após a imersão em soluções de água deionizada, ácido cítrico ou ácido clorídrico. Após a ciclagem, os valores de dureza da dentina diminuíram para todos os materiais. Para a dentina restaurada com Adper Single Bond 2, os menores valores foram encontrados próximo a camada híbrida (10 μm) enquanto que para a dentina restaurada com os sistemas adesivos autocondicionantes (Clearfil SE Protect e One Up Bond F), esses valores foram mantidos em todas as distâncias avaliadas. Para os materiais Riva Self Cure e Riva Light Cure somente nas leituras iniciais a distância foi determinante na dureza, uma vez que quanto maior a distância da interface de união, maiores eram os valores encontrados. Com relação ao módulo de elasticidade, para a dentina restaurada com Adper Single Bond 2, não houve diferença significante em todas as distâncias avaliadas. Já na dentina restaurada com os sistemas adesivos autocondicionantes... / The aim of this study was to evaluate the effect of erosive pH cycling with solutions that simulate dental erosion in the hardness and elastic modulus of dentin restored with fluoride-releasing restorative materials. Forty five bovine dentine slabs (6,0 mm x 6,0 mm) were restored with 5 restorative materials: Adper Single Bond 2 total-etch adhesive system + Filtek Z250 composite resin; One Up Bond F self-etching adhesive system + Filtek Z250 composite resin; Clearfil SE Protect self-etching adhesive system + Filtek Z250 composite resin; Riva Self Cure conventional glass ionomer cement and Riva Light Cure light curing glass ionomer cement. The values of hardness and elastic modulus of dentin (10μm, 30μm, 50μm e 70μm) were evaluated in digital ultramicrohardner tester before and after immersion in solutions of deionized water, citric acid and hydrochloric acid. After cycling, the hardness of dentin decreased for all materials. For dentin restored with Adper Single Bond 2, the lowest values were found close to hybrid layer (10 μm), while for the dentin restored with One Up Bond F and Clearfil SE Protect, the values remained unaltered in all the evaluated distances. For dentin restored with Riva Self Cure and Riva Light Cure only in the initial measurements, the distance had a significant effect in the hardness values, since the greater the distance to the bonding interface, higher values of hardness were found. For the elastic modulus analysis, dentin restored with Adper Single Bond 2 showed no significant difference when distances from bonding interface were compared. Dentin restored with self-etching adhesive system (One Up Bond F and Clearfil SE Protect) and glass ionomer cements (Riva Self Cure and Riva Light Cure) showed a reduction in the elastic modulus values from the bonding interface, but after 30 μm the difference was not significant.
158

Resistência de união da resina composta à dentina irradiada com laser de Nd:YAG, utilizando o teste de microtração

Castro, Fabrício Luscino Alves de [UNESP] 03 March 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:27Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-03-03Bitstream added on 2014-06-13T19:41:17Z : No. of bitstreams: 1 castro_fla_dr_arafo.pdf: 7860920 bytes, checksum: 606bfd94b4340fc881305e2763b4ba4a (MD5) / Este estudo avaliou, por meio do teste de microtração, a resistência de união da resina composta à dentina, verificando a influência da irradiação do tecido com laser de Nd:YAG, realizada após a aplicação do adesivo, e associada ou não ao pré-tratamento ácido do mesmo. Superfícies dentinárias planas foram criadas em 37 terceiros molares humanos extraídos, dos quais, 36 foram selecionados para teste. Os adesivos Single Bond (SB) e Clearfil SE Bond (CSEB) foram aplicados, com ou sem o condicionamento da dentina (ácido fosfórico para o SB e primer auto-condicionante para o CSEB). Após aplicação dos adesivos e antes de sua fotopolimerização, as superfícies foram irradiadas com laser, exceto para os controles, testando-se duas potências, 0,75 e 1W. No total, 12 grupos foram criados, 6 para cada sistema. Coroas de resina composta foram construídas e os dentes armazenados a 37ºC por 24h. Depois, os mesmos foram cortados serialmente, resultando em espécimes com secção transversal de união aproximada de 0,49mm2, que foram, em seguida, testados sob tração. Espécimes fraturados, representativos dos diferentes grupos, tiveram suas superfícies dentinárias observadas ao microscópio eletrônico de varredura (MEV). As interfaces adesivas de 2 espécimes não testados em cada grupo também foram observadas ao MEV. O sistema SB foi aplicado na superfície do dente remanescente (sem ácido e sem laser), a coroa de resina construída e o conjunto seccionado em duas metades, para observação da interface ao MEV. Os resultados mostraram que a aplicação do laser aumentou a resistência à microtração apenas quando o SB foi aplicado sem o condicionamento ácido prévio e em relação ao grupo em que só o adesivo foi aplicado (SB / sem ácido/ sem laser). Entretanto, estes valores foram inferiores aos obtidos quando o SB foi... / This study evaluated if the irradiation of dentin trough the adhesive applied on it affected micro-tensile bond strength of composite to this tissue. Flat dentin surfaces were created in 37 extracted human third molars. Thirty-six teeth were selected and received surface treatments. Single Bond (SB) and Clearfil SE Bond (CSEB) systems were individually applied after dentin had been acid-etched or not, with phosphoric acid for SB or self-etching primer for CSEB. Immediately after adhesives application and before light curing, surfaces were lased, except for controls, using two power settings, 0.75 and 1W. So, 12 groups were designed, 6 for each bonding system. After that, composite crowns were built-up over the treated surfaces and the teeth were stored in distillated water, at 37ºC, for 24h. The teeth were serially sectioned in beams with cross-sectional area of approximately 0,49mm2, and the specimens were stressed to failure under tension using a testing machine. Representative fractured specimens were selected and had their dentin surfaces observed under scanning electron microscopy (SEM). Interfaces of two untested beams were also observed under SEM. Moreover, the dentin surface of one additional tooth received SB application (with neither acid etching nor laser irradiation), a composite crown was built-up on it and the tooth was cut longitudinally in two halves, which had their dentin/resin interfaces observed under SEM. This study showed that laser irradiation increased micro-tensile bond strength only in Groups 5 and 6, where SB was applied without previous dentin acid etching, in comparison to the group where this adhesive was used alone (Group 4 - no etching / no laser). However, these values were lower than those found when dentin was etched. There was not an improvement in bond... (Complete abstract, click electronic address below)
159

Análise in vitro da resistência de união da resina composta à dentina tratada com diferentes sistemas adesivos

Xavier, Cláudia Cristina Galvão [UNESP] 28 February 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:27Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-02-28Bitstream added on 2014-06-13T20:41:46Z : No. of bitstreams: 1 xavier_ccg_dr_arafo.pdf: 2502909 bytes, checksum: 3349b0ab0c81badc5aa688fd716eaa6b (MD5) / Este trabalho teve como objetivo avaliar in vitro a força de união da resina composta à dentina tratada com quatro adesivos dentinários, sendo dois sistemas universais simplificados (G1- Prime & Bond® NT/ Dentsply, G2- Single Bond/ 3M) e dois auto-condicionantes (G3- AdheSE® / Vivadent, G4- Adper- PromptL-Pop/ 3M). Para a realização deste estudo, foram selecionados 20 terceiros molares humanos íntegros e livres de cárie, que tiveram suas superfícies oclusais cortadas em 3mm. Após o corte, cada grupo de dentes receberam seus respectivos sistemas de tratamento adesivo, pré-selecionados. Todas as amostras de dentes foram restauradas com a resina composta Tetric Ceram® / IvoclarVivadent, termocicladas em 550 ciclos e cortadas. Dessa forma, obtendo-se espécimes de 1,0mm2 l0,1mm2 que foram levados a uma Máquina de Teste Universal onde foi realizado o ensaio de microtração. Os tipos de fraturas foram analisados, mediante microscopia óptica (40X) e as fraturas mais representativas foram levadas à microscopia eletrônica de varredura. Os resultados mostraram que os sistemas universais simplificados (G1 e G2) apresentaram valores de resistência de união mais elevados do que os sistemas auto-condicionantes (G3 e G4). A maioria das fraturas encontradas foram do tipo adesiva para os grupos G3 e G4, enquanto nos grupos G1 e G2 87% dos modos de fraturas foram distribuídas entre adesivas e coesivas da resina. / This work had with aim to evaluate in vitro the bond strength of composite resin to dentine bonded with four dentin adhesives. In this study, were used two one-step adhesive systems (G1- Prime & Bond® NT/Dentsply, G2-Single Bond/ 3M)and two self-etching adhesive systems (G3- AdheSE® /Vivadent, G4- Adper Prompt L-Pop/3M). For this, were chosen twenty human healthy third molars, that had their oclusal surfaces cut in 3mm. After the cut, each group of teeth received their respectives adhesive systems, even then chosen. All the samples were restored with the composite Tetric Ceram® / IvoclarVivadent, thermocycled 550 times and cut. Then, obtaining specimens of 1,0mm2 l 0,1mm2 that were made a test of micro tensile bond strength in a Universal Test Machine. The fractures were analyzed in a optical microscope (40X), and the more representative fractures were then analyzed at scanning electronic microscope. The results revealed that the one-step adhesive systems (G1 and G2) showed higher values of bond strength compared to the self-etching adhesive systems (G3 and G4). The fractures more commum were the adhesive type in the G3 and G4 groups, while in the G1 and G2 groups, 87% of the fractures were the adhesive and cohesion of resin types.
160

Análise da resistência adesiva à dentina de diferentes sistemas adesivos pelo teste de microtração e microscopia eletrônica de varredura

Mazur, Rui Fernando [UNESP] 10 November 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:27Z (GMT). No. of bitstreams: 0 Previous issue date: 2003-11-10Bitstream added on 2014-06-13T20:41:47Z : No. of bitstreams: 1 mazur_rf_dr_arafo.pdf: 2691655 bytes, checksum: aa6766566238765dc0a1f4d5cb633eda (MD5) / O objetivo deste trabalho foi realizar, in vitro, avaliação da resistência de adesiva pelo teste de microtração de dez sistemas adesivos diferentes. Os sistemas adesivos One Up Bond F - Tokuyama, Clearfil SE Bond - Kuraray, Adper Prompt L-Pop, Single Bond - 3M/ESPE, One Step - Bisco, One Step Plus - Bisco, Prime&Bond NT - Dentsply, Excite - Vivadent, Scotchbond Multi - Uso - 3M/ESPE e All Bond 2 - Bisco. Para a realização do teste foram utilizados quarenta dentes molares hígidos, sendo que destes dentes dez foram utilizados para a microscopia eletrônica de varredura. Para a realização do teste de microtração os dentes foram cortados na superfície oclusal com disco diamantado e posteriormente foram desgastados com discos de lixa. Posteriormente as amostras foram restauradas com os respectivos sistemas adesivos e resina composta Z-100 com tempo de polimerização de 40 segundos cada incremento. Após vinte e quatro horas de armazenagem em temperatura de 37ºC os dentes foram seccionados com disco diamantado com finalidade de obter palitos com área de 1,0 +- 0,2 mm2. Após o corte os palitos foram armazenados em temperatura de 37ºC por vinte e quatro horas e em seguida foram levados para a máquina de ensaio universal EMIC 500 DL onde os palitos foram tracionados com velocidade de 1 mm/min. Os resultados foram analisados pelo através dos testes de normalidade de Lilliefors e de homogeneidade de variância de Bartlett. Quando alguns dos pressupostos não se verificaram, utilizou-se o teste não paramétrico de Kruskal - Wallis. Os resultados obtidos foram em ordem decrescente de 36,73 +- 10,52 para o sistema adesivo One Up Bond F, seguido do sistema de três etapas All Bond 2 com 34,29 +- 12,63 para o sistema adesivo One Step Plus foi de 33,18 +- 11,33 para o sistema Adper Prompt L-Pop de 31,76 +- 11,3, sistema One Step de 29,02 +- 11,28, para o... . / The aim of this study was to analyze the bond strength of ten adhesive systems: One Up Bond F - Tokuyama (OU); Adper Prompt L-Pop - 3M-ESPE (AP); Clearfil SE Bond - Kuraray CO. (SE); Prime Bond NT - Caulk-Dentsply (NT); Single Bond - 3M-ESPE (SB); One Step - Bisco (OS); One Step Plus - Bisco (OP); Excite - Vivadent (EX); Scotchbond Multi - Purpose (SMP) e All Bond 2 - Bisco (AB). Methods: Forty freshly extracted human teeth were transversely wetcut using a diamond disk in order to expose the occlusal dentin surface. Then the adhesive systems were applied according to the manufacturer's instruction. The teeth were restored with composite resin Z-100 (3M) and stored in distilled water at 37ºC for 24 hours. A slow-speed diamond disk was used to prepare microtensile test specimens, with a bonded area of 1,00 +- 0,2 mm2. Each group was composed of thirty sticks, which were stored in distilled water at 37ºC for 24 hours. The sticks were bonded on a universal testing machine at a cross head speed of 1 mm/min. The following results demonstrate values microtensile bond strengths in MPa. Data were statistically analyzed by Kruskal-Wallis Test (p<-0.05). The bond strength values were 36,73 +- 10,52 for One Up Bond F, 34,29 +- 12,63 for All Bond 2, 33,18 +- 11,33 for One Step Plus, 31,76 +- 11,3 for Adper Prompt L-Pop, 29,02 +- 11,28 for One Step, 28,82 +- 14,74 for Single Bond, 28,08 +- 12,09 for Clearfil SE Bond, 26,31 +- 9,02 for Scotchbond Multi - Purpose, 21,35 +- 10,22 for Prime&Bond NT and 19,52 +- 10,08 for Excite. Ten teeth were analysed by SEM and all of them showed resin into the dentin tubules. Most of fractures were adhesive in the composite/teeth interface. One up bond F (OU) resulted in higher bond strength when compared to all the other systems tested and Excite resulted in lower bond strength. Self-etching systems were not statistically... (Complete abstract, click electronic address below).

Page generated in 0.2407 seconds