• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 839
  • 37
  • 37
  • 37
  • 37
  • 36
  • 29
  • 9
  • 7
  • 6
  • 4
  • 3
  • 3
  • 1
  • 1
  • Tagged with
  • 899
  • 499
  • 251
  • 202
  • 193
  • 178
  • 152
  • 140
  • 140
  • 121
  • 114
  • 97
  • 97
  • 96
  • 94
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
171

Avaliação "in vitro" da resistência de união de dois sistemas adesivos dentinários à dentina bovina antes e após a termociclagem: teste de cisalhamento e análise estereomicroscópia /

Amendola, Alessandra Buhler. January 1999 (has links)
Orientador: José Roberto Rodrigues / Banca: José Claudio Martins Segalla / Banca: Clovis Pagani / Resumo: O objetivo do presente estudo foi o de avaliar e comparar a efetividade da união de dois sistemas adesivos: Scotchbond Multi-Uso Plus (3M) e Etch & Prime 3.0 (Degussa) à dentina bovina antes e após a termociclagem, bem como o de avaliar o tipo de fratura ocorrido na interface dentina/material. Empregaram-se dentes bovinos, que tiveram a superfície vestibular desgastada com lixas de papel de granulação crescente para a exposição da dentina. Os espécimes foram divididos em dois grupos, nos quais aplicou-se os sistemas adesivos e, posteriormente, a resina composta Z100 (3M) por meio de uma matriz de teflon com 4mm de diâmetro. Estes grupos foram subdivididos em dois subgrupos (A e B). O subgrupo A foi submetido ao ensaio mecânico de cisalhamento após 24h e o subgrupo B recebeu a ciclagem térmica, que consistiu de quinhentos ciclos entre 5°C e 55°C, com duração de 30s em cada temperatura, para depois ser submetido ao teste de cisalhamento. O ensaio mecânico foi realizado em máquina lnstron Universal à velocidade de 0,5mm/min. As superfícies fraturadas foram analisadas em estereomicroscópio (Karl Zeiss). A aplicação do teste estatístico ANOVA, ao nível de significância de 0,05, revelou que os valores de resistência de união dos dois sistemas adesivos avaliados não apresentaram diferença estatisticamente significativa e que a utilização da termociclagem não influenciou a resistência adesiva dos materiais testados. O Scotchbond Multi-Uso Plus apresentou predominância de falhas adesivas e o Etch & Prime 3.0 apresentou maior quantidade de fraturas mistas, seguidas pelas fraturas adesivas / Abstract: The aim of fhe present study was to investigate the shear bond strength of two adhesive systems, Scotchbond Multi-Purpose Plus (3M) and Etch & Prime 3.0 (Degussa), to bovine dentin, before and after thermal cycling. Bovine incisors were embedded in self-cured resin and labial dentin surfaces were ground with sequential abrasive sandpapers. The specimens were separated into two groups to receive the adhesive systems. A composite resin cylinder (Z100-3M) was bonded to the dentinal surface. The two groups were divided into two more groups (A and B). The subgroup A was shear tested after 24h and the subgroup B was subjected to 500 thermal cycles, between 5ºC and 55ºC, with a dwell time of 30 seconds and, then, shear tested. The bond strength was performed on a Universal lnstron machine 4301, with a load cell of 500 Kg and a speed of 0,5mm/min. The mode of failure were classified. The analysis of variance (ANOVA), at 5% significant level, revealed that there were no significant differences among the bond strength of the two adhesive systems, and that the thermal cycling did not significantly influence strength of the two materials tested. The Scotchbond Multi-Purpose Plus showed a considerable number of adhesive failures and the Etch & Prime 3.0 showed predominantly mixed fractures, followed by adhesive fractures / Mestre
172

Avaliação da obliteração de túbulos dentinários, concentração mineral e permeabilidade dentinária após o uso de dentifrícios contendo trimetafosfato de sódio microparticulado e nanoparticulado : estudo in vitro /

Favretto, Carla Oliveira. January 2016 (has links)
Orientador: Denise Pedrini Ostini / Coorientador: Alberto Carlos Botazzo Delbem / Banca: Robson Frederico Cunha / Banca: Daniela Rios / Banca: Daniela Cristina de Oliveira / Resumo: O objetivo deste trabalho foi avaliar in vitro a ação do trimetafosfato de sódio microparticulado (TMPm) ou nanoparticulado (TMPn) associado ao fluoreto (F) em formulações de dentifrícios na obliteração dos túbulos dentinários (TD), concentração mineral e condutância hidráulica. Blocos de dentina radicular bovina (4×4×2 mm) foram planificados e os TD desobliterados com solução de ácido fosfórico a 37%. Para o estudo da avaliação da obliteração dos túbulos e concentração mineral, os blocos (n=20/grupo) foram submetidos à escovação mecânica (2x/dia) durante 7 dias com dentifrícios: placebo, 1100 ppm F, 1100 ppm F associado a 3% TMPm, 1100 ppm F associado a 3% TMPn. Ao final dos tratamentos, dez blocos por grupo foram imersos em ácido cítrico (pH 3,2), durante 1 minuto. O número, diâmetro e área de TD desobstruídos foram quantificados utilizando microscopia eletrônica de varredura (MEV) e a % atômica dos elementos químicos (Ca, P, C, N e O) dos precipitados presentes nos TD foi determinada por energia dispersiva de raios-X. Foi avaliada a concentração mineral da dentina (gHAp × cm-3) utilizando um microtomógrafo com resolução espacial de 1,5 μm. Os dados foram submetidos à análise de variância (2-critérios) seguida pelo teste de Student-Newman-Keuls (p<0,05). Os dentifrícios contendo TMPm e TMPn produziram maior obliteração dos TD e maior concentração mineral quando comparados com outros grupos. Não foram observadas diferenças significativas entre 1100 TMPm e 1100 TMPn ou entre ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The objective of this study was to evaluate in vitro the effect of TMP microparticles (TMPm) or nanoparticles (TMPn) associated with fluoride (F) in toothpaste formulations on the obliteration of dentinal tubules (DT), mineral concentration and hydraulic conductance. Bovine root dentin blocks (4×4×2 mm) were ground flat and the DT were unobstructed by phosphoric acid 37%. For study of evaluation of the tubules obliteration and mineral concentration, the blocks (n=20/group) were submitted to mechanical brushing (2x/day) during 7 days with toothpastes: placebo, 110 0 ppm F, 1100 ppm F associated with 3% TMP m, 1100 ppm F associated with 3% TMPn . After that, ten blocks of each group were immersed in citric acid (pH 3.2) for 1 minute. The number, diameter and area of unobstructed DT were quantified using scanning electron microscopy ( SEM ) and atomic % of chemical elements (Ca, P, C, N and O) from precipitates in DT were determined by energy-dispersive X-ray . Dentin mineral concentration (g HAp × cm -3 ) was evaluated utilizing Micro-CT at 1.5 μm of spatial resolution. Data were submitted to 2-way ANOVA, followed by Student-Newman-Keuls test (p<0.05). Toothpastes containing TMPm and TMPn promoted higher obliteration of DT and greater mineral concentratio n when compared to other groups. No significant differences were observed between 1100 TMPm and 1100 TMPn, or between placebo and 1100 ppm F; however 1100 ppm F group had higher mineral concentration compared to placebo. Higher Ca/P ratios Carla Oliveira Favretto were observed in the groups treated with TMP; the acid challenge reduced Ca/P ratio for all groups. The atomic % of C and N was significantly lower for 1100 TMPm and 1100 TMP n before acid challenge, but increased afterwards. T he atomic % of O was higher before before aci d challenge to T MP groups . For study of hydraulic conductance ... (Complete abstract electronic access below) / Doutor
173

Influência do tratamento expectante sobre propriedades acidogênicas e acidúricas de Streptococcus mutans e LLactobacillus acidophilus/

Correia, Marília Ferreira. January 2014 (has links)
Orientador: Denise Madalena Palomari Spolidório / Banca: Elisa Maria Aparecida Giro / Banca: Fernanda Lourenção Brighenti / Banca: Juliana Rico Pires / Banca: Cristiane Duque / Resumo: A remoção parcial de tecido cariado, realizada por meio do tratamento expectante, apresenta um alto índice de sucesso clínico, além de promover uma redução dos microrganismos presentes na dentina cariada. Porém, a permanência de tais microrganismos geram questões a respeito de certas propriedades que tais bactérias apresentam que as fazem ser capazes de continuar desmineralizando o tecido dentinário. Assim, esse estudo analisou as propriedades acidogênicas e acidúricas de Streptococcus mutans e Lactobacillus acidophilus, além de avaliar alterações clínicas como coloração e consistência e quantificar através de meios de cultura específicos alguns microrganismos presentes nesse tipo de lesão. Para isto, foram selecionados 20 pacientes apresentando molares decíduos com lesões passíveis de receber o tratamento expectante, sendo realizado coletas de lascas de dentina em dois momentos diferentes: na primeira intervenção após a remoção parcial de tecido cariado e na segunda intervenção durante a reabertura da cavidade 90 dias após o selamento provisório da lesão. As amostras coletadas foram cultivadas, identificadas e quantificadas, além de serem analisadas quanto aos testes fenotípicos de acidogenicidade e aciduridade. Os dados foram submetidos a análise estatística, e observou-se que apesar de ocorrer uma diminuição estatisticamente significante no número de microrganismos viáveis analisados, não houve diferença estatística com relação as propriedades acidogênicas e acidúricas de Streptococcus mutans e Lactobacillus acidophilus coletados nos dois momentos especificados. Conclui-se que o tratamento expectante apesar de promover alterações clínicas como escurecimento e endurecimento dentinário, associado com a redução no número de microrganismos viáveis, parece não exercer influência nas características fenotípicas de aciduridade...(Complete abstract electronic access below) / Abstract: Partial caries removal performed by the stepwise treatment has a high rate of clinical success and also promotes a reduction of microorganisms in carious dentin. However, the permanence of these microorganisms raises the question about certain properties which such bacteria present that make them able to continue the demineralization of the dentin. Thus, the aim of this study was to examine the acidogenic and aciduric properties of Streptococcus mutans and Lactobacillus acidophilus as well as to assess clinical changes in color and consistency of carious dentine and to quantify some microorganisms present in this type of lesion. Therefore 20 patients presenting deep caries lesion in primary molars eligible to receive the stepwise treatment were selected and dentin samples were collected in two different moments: in the first intervention just after partial caries removal and in the second intervention during the reopening of the cavity, 90 days after the temporary sealing of the lesion. The samples were cultured, identified and quantified, and were analyzed for phenotypic tests to available their acidogenicity and aciduricity. Data were statistically analyzed and it was observed that despite a decrease statistically significant in the number of viable microorganisms, there was no statistical difference in the acidogenicity and aciduricity properties of Streptococcus mutans and Lactobacillus acidophilus over the time. It was concluded that the stepwise treatment promoted clinical changes as darkening and hardening of carious dentine and also promoted a reduction in the number of viable microorganisms, although it seemed not to influence the phenotypic characteristics like acidogenicity and aciduricity of the species analyzed during the period of 90 days. / Doutor
174

Citotoxidade de cimentos resinosos sobre célular obtidas da polpa de dentes humanos (HDPCs) e odontoblastóides (MDPC-23) /

Pontes, Elaine Cristina Voltolini. January 2014 (has links)
Orientador: Carlos Alberto de Souza Costa / Banca: Gelson Luis Adabo / Banca: Adriano Lima / Resumo: O objetivo deste estudo foi avaliar a citotoxicidade de cimentos resinosos quando aplicados sobre cultura de células odontoblastóides (MDPC-23) e pulpares humanas (HDPC). Os seguintes grupos foram formados: G1 - controle (sem tratamento); G2 - Rely X Luting 2; G3 - Rely X U200; G4 - Rely X ARC. Corpos de prova padronizados, preparados com os cimentos, foram imersos em 1 mL de meio de cultura (DMEM) por 24hs para obtenção dos extratos (DMEM + componentes liberados dos cimentos). Após aplicar os extratos sobre as células por 24hs, a viabilidade (MTT assay) e tipo de morte celular (Anexina/PI), bem como a morfologia das células (MEV) foram avaliados. Os dados obtidos foram submetidos à análise estatística de Kruskal-Wallis complementada por Mann-Whitney (α=5%). A análise química dos extratos foi realizada por cromatografia liquida de alta performance (HPLC). Nos grupos G2, G3 e G4, observou-se redução de 95,8%, 31,5% e 22,7% na viabilidade das células MDPC-23, respectivamente. Redução de 89,4% para G2 e aumento em 11,3% e 29% para G3 e G4, respectivamente, foram observados para as HDPCs. Para as células MDPC-23, redução significativa de viabilidade ocorreu em G2 e G3 quando comparado à G1; todavia, para as HDPCs esta redução foi observada apenas em G2 (p<0,05). Para ambas as culturas usadas no estudo, ocorreu 100% de morte celular por necrose apenas em G2, onde o pH do extrato era ácido. Em G3, onde uma pequena quantidade de TEGDMA foi detectado no extrato, houve reduzida morte celular por necrose e discreta alteração morfológica nas células. Todavia, nenhum dano celular ocorreu em G4. De maneira geral, a células MDPC-23 são mais sensíveis do que as HDPCs. Concluiu-se que apenas o cimento Rely X Luting 2 causou intenso efeito citotóxico para ambas culturas de células pulpares usadas neste estudo. Rely X U200 apresentou discreta citotoxicidade, enquanto o cimento Rely X ARC não foi tóxico para as células pulpares... / Abstract: The aim of this study was to evaluate the cytotoxicity of luting cements on cultured MDPC-23 odontoblast-like cells and human dental pulp cells (HDPCs). The following groups were formed: G1 - control (no treatment), G2 - Rely X Luting 2, G3 - Rely X U200; G4 - Rely X ARC. Standard round specimens prepared with resin cements were immersed in 1 ml of culture medium (DMEM) for 24 hours to obtain the extract (DMEM + components released from the cement). After applying the extracts to the cells for 24 hours, the viability (MTT assay) and type of cell death (Annexin/PI) as well as cell morphology (SEM) were evaluated. The data obtained was submitted to Kruskal-Wallis statistical analysis complemented by Mann-Whitney test (α=5%). The chemical analysis of the extracts was performed by high performance liquid chromatography (HPLC). In G2, G3 and G4, there was a reduction of 95.8 %, 31.5 % and 22.7 % in the MDPC-23 cells viability, respectively. A reduction of 89.4 % for G2, as well as an increase of 11.3 % and 29% for G3 and G4 was observed for the HDPCs, respectively. Significant reduction of MDPC-23 viability occurred for G2 and G3 compared to G1. However, for HDPCs this reduction was only observed in G2 (p<0.05). For both cell cultures used in this study, there was 10 % of cell death by necrosis only in G2, in which the pH of the extract was acid. In G3, where a small amount of TEGDMA was detected in the extracts, there was reduced cell death by necrosis and a discrete morphological alteration in cells. No cellular damage occurred in G4. In general, the MDPC-23 cells are more sensitive than HDPCs against the toxicity of resin cement components. It was found that only the Rely X Luting cement caused intense cytotoxic effect for both pulp cell cultures used in this study. Rely X U200 showed mild cytotoxicity, whereas the cement Rely X ARC was not toxic to the pulp cells. / Mestre
175

Propriedades mecânicas, físico-químicas e biológica de adesivo experimental com incorporação de epigalocatequina-3-galato /

Fonseca, Beatriz Maria da. January 2015 (has links)
Orientador: Sérgio Eduardo de Paiva Gonçalves / Co-orientador: Anuradha Prakki / Banca: Alexandre Luiz Souto Borges / Banca: Kátia Regina Hostílio Cervantes Dias / Banca: Roberta Caroline Bruschi Alonso / Banca: César Rogério Pucci / Resumo: O objetivo desse estudo foi avaliar o efeito da adição de EGCG em adesivo experimental na manutenção da camada híbrida, avaliando suas propriedades mecânicas, físico-químicas e biológica. A primeira etapa do estudo envolveu a manipulação do adesivo com incorporação de EGCG (0,5%, 1,0% e 1,5%) na relação BisGMA 55% / HEMA 45%, canforoquinona 0,5% e DMAEMA 0,5%. O grau de conversão (GC) dos monômeros foi avaliado por Espectroscopia micro-Raman (GC : EGCG 1.5 - 99,11a; EGCG 1.0 - 99,02a; EGCG 0.5 - 96,58ab; Controle - 85,47b). A segunda etapa envolveu a realização de análises mecânicas e físico-químicas [resistência flexural (RF) e módulo de elasticidade (ME); módulo de resiliência (RE) e resistência a compressão(RCo); sorção (A) e solubilidade (S) em água; contração de polimerização (CP)]; teste de resistência à microtração (RA) imediato (24 h) e longitudinal (6 meses); e teste biológico [ensaio de citotoxicidade (CI)]. Os resultados foram: RF, ME, RE, RCo e CP não apresentaram diferença significativa entre os grupos. Os testes de A e S apresentaram redução dos valores para os grupos EGCG 0.5 e 1.0; RA imediato (24 h) não apresentou diferença entre os grupos. Após 6 meses houve redução dos valores somente para os grupos Controle e EGCG 1.5, os grupos EGCG 0.5 e 1.0 mantiveram os valores de RA constantes. CI: a incorporação de EGCG aumentou a viabilidade celular nas diluições de 0,1% e 1,0%, comparado ao grupo Controle. Pôde-se concluir que a incorporação de EGCG independente da concentração não afetou o GC. As concentrações de 0,5% (100 μg/ml) e 1,0% (200 μg/ml) em volume de EGCG é capaz de preservar a camada híbrida formada e prorrogar a longevidade das restaurações em resina composta, além de aumentar a viabilidade celular / Abstract: The aim of this study was to evaluate the effect of EGCG in an experimental adhesive to reduce the hybrid layer degradation, through mechanical, physical-chemical and biological analysis. The first step of this study involved manipulation of the adhesive model with the incorporation three different concentrations of EGCG (0.5%, 1.0% and 1.5%) in relation BisGMA 55% / 45% HEMA, 0.5% camphorquinone and 0.5% DMAEMA. The conversion degree (DC) of adhesive monomers was evaluated by micro-Raman spectroscopy (GC: EGCG 1.5 (1.5%) - 99,11a; EGCG 1.0 (1.0%) - 99,02a; EGCG 0.5 (0.5%) - 96,58ab; Control - 85,47b). The second step involved the mechanical and physicochemical analysis [flexural strength (FS) and elastic modulus (EM); resiliency modulus (RM) and compressive bond strength (CBS), sorption (A) and solubility (S) in water; shrinkage polymerization (SP)]; microtensile bond strength test (μTBS) immediately (24 h) and longitudinal (6 months) and biological analyze [cytotoxicity assay (CY)]. The results were: FS, EM, RM, CBS and SP showed no significant difference between groups; A and S tests showed reduced values only for EGCG 0.5 and 1.0 groups. RA immediately (24) did not differ between groups. After six months there was a reduction of the values only for the control and EGCG 1.5 groups, EGCG groups 0.5 and 1.0 maintained the RA values. CY: EGCG incorporation increased the cell viability in 0.1% and 1.0% dilutions compared to the control group. It was concluded incorporation of EGCG at 0.5, 1.0 and 1.5 concentrations did not affect the degree of conversion of the monomers. Thus, the incorporation of 0.5% (100 μg/ml) and 1.0% (200 μg/ml) EGCG amount can preserve the hybrid layer formed and prolong longevity composite resin restorations in addition to increasing cell viability. / Doutor
176

Ablação de esmalte e dentina bovinos e humanos com laser de Ti:safira no regime de femtossegundos: análises morfológicas e fisico-químicas comparativas /

Dutra-Corrêa, Maristela. January 2008 (has links)
Resumo: Dentes bovinos têm sido convencionalmente utilizados em pesquisas odontológicas substituindo dentes humanos. Diferenças nas propriedades físico-químicas, estruturais e morfológicas dos substratos representarão diferenças na resposta frente a diversos tratamentos. Foi investigada a ablação em esmalte e dentina de dentes bovinos (30) e humanos (30) com laser de Ti:Safira, no regime de femtossegundos (70fs), com λ= 800±1 nm, taxa de repetição=1 KHz, utilizando diferentes potências médias com diferentes tempos de exposição. Foram realizadas análises morfológicas e físico-químicas. Os corpos-de-prova foram observados ao microscópio de luz, ao MEV e analisados por EDX. As microcavidades em esmalte (bovino e humano) apresentaram ablação precisa, integridade e definição das margens. No esmalte humano não houve danos térmicos ou microfraturas; o bovino apresentou microfraturas, provavelmente resultado de sua menor resistência à ablação com laser. As microcavidades da dentina (bovina e humana) apresentaram bordas definidas, entretanto com microfraturas, sendo que na dentina bovina foram mais numerosas, mais amplas e mais intensas, mostrando maior susceptibilidade frente à irradiação com laser. Quanto à proporção Ca/P, as alterações proporcionais entre números de átomos de Ca em relação ao P, não foram estatisticamente significantes, para nenhum tecido. Conclui-se que o laser de Ti:Safira no regime de femtossegundos, além de muito rápido, potente e seguro, tem a vantagem de poder ser bem controlado e preciso, promovendo profundidades pequenas e específicas. Diante dos resultados e dependendo do tipo de tecido, fica evidente a necessidade de prévio conhecimento das diferenças entre eles antes da direta extrapolação dos resultados obtidos em substrato bovino para humano. / Abstract: Bovine teeth have been conventionally used in dental research to replace human teeth. Differences in the physicochemical, structural and morphological properties of these substrates cause differences in their response to several treatments. This study investigated the ablation of enamel and dentin of bovine teeth (30) and human teeth (30) using a Ti:Sapphire laser at Femtosecond pulse width (70fs), λ= 800±1nm and repetition rate of 1 KHz. Different output power levels and irradiation times were investigated. Morphological and physicochemical analysis were conducted. Irradiated specimens were evaluated under light microscopy, SEM and EDX. Microcavities in bovine and human enamel showed accurate ablation, with sharp margins and preserved morphologies. Human enamel did not exhibit induced thermal damage or microfractures; bovine enamel presented microfractures, probably due a lower resistance to laser ablation. The microcavities in dentin (bovine and human) presented defined borders, yet with microfractures, which were more frequent, wider and more intense in the bovine dentin, demonstrating a higher susceptibility to laser irradiation. Concerning the Ca/P ratio, the proportional alterations between the numbers of Ca atoms compared to P atoms were not statistically significant for any tissue. In this study Femtosecond Ti:Sapphire laser showed to be a fast, powerful and safe ablation system. Additionally, it promotes removal at small and specific depths. Considering the present results and depending on the type of tissue, it is clear that previous knowledge on the differences between them is required before direct extrapolation of results obtained in bovine substrate to the human substrate. / Orientador: José Roberto Rodrigues / Coorientador: Vanderlei S. Bagnato / Banca: José Roberto Rodrigues / Banca: Cristina Kurachi / Banca: Victor Elias Arana-Chavez / Banca: Camilo Anauate Netto / Banca: Sérgio Eduardo de Paiva Gonçalves / Doutor
177

Dentina humana e bovina estudo da profundidade de desmineralização e da espessura da hibridização empregando-se sistema adesivo convencional ou autocondicionante : análise em mev /

Anido, Andréa Anido. January 2005 (has links)
Orientador : Sérgio Eduardo de Paiva Gonçalves. / Doutor
178

Ação de enxaguatórios clareadores e sua associação ao clareamento caseiro com peróxido de carbamida /

Oliveira, Juliana Boa Sorte de. January 2016 (has links)
Orientador: Caneppele, Taciana Marco Ferraz / Banca: Eduardo Bresciani / Banca: Carlos Martins Agra / Resumo: Objetivos: o objetivo deste estudo foi comparar a efetividade de enxaguatórios clareadores sobre dentes, clareados previamente ou não, expostos a corantes alimentícios. Material e Método: Cento e vinte espécimes de esmalte e dentina de 3 mm de diâmetro foram obtidos a partir de incisivos bovinos. Os espécimes foram manchados por 14 dias em caldo de manchamento. Após o manchamento, a leitura inicial da cor foi realizada, por meio do espectrofotômetro CM-2600d (Konica Minolta, Osaka, Japão). Sessenta espécimes (Subgrupos PC) foram submetidos ao clareamento com Peróxido de Carbamida a 10% por 14 dias. Após, foram subdividos em 4 subgrupos, com ciclos de manchamento (5 min) e enxaguatório (2 min) por 12 semanas, sendo PC-LI: Listerine Whitening Pré- escovação; PC-PL: Plax Whitening; PC-BP: Bromelina + Papaína; PC-AG: água deionizada. Os subgrupos LI, PL, BP e AG foram submetidos aos mesmos ciclos citados, porém não foram submetidos ao clareamento prévio. A leitura de cor dos espécimes foi feita após 4, 8 e 12 semanas de tratamento com os enxaguatórios. Os dados foram coletados e submetidos à Análise de variância (ANOVA) de medidas repetidas. A comparação entre os subgrupos para a avaliação das diferenças estatísticas foi realizada pelo Teste de Tukey. Todos os testes empregados admitiram 5% como nível de significância estatística. Os resultados mostraram que os valores de ΔL*, Δa*, Δb* e ΔE* confirmaram o clareamento para os subgrupos PC-LI, PC-PL, PC-BP e PC-AG, após o tratamento com peróxido de carbamida, e para os subgrupos PC-LI, PC-PL, LI e PL, após os ciclos manchamento-enxaguatório. Os subgrupos PC-BP e BP assemelharam-se aos subgrupos controle PC-AG e AG. Conclui-se, desse modo, que o enxaguatório bucal Listerine Whitening apresentou maior efeito clareador, seguido do enxaguatório Plax Whitening. Porém, nenhum desses enxaguatórios foi capaz de produzir clareamento semelhante ao evidenciado pelo.. / Abstract: Objectives: The aim of this study was to compare the effectiveness of whitening mouthrinses on teeth previously whitened or not, exposed to food dyes. Material and Methods: One hundred and twenty specimens of enamel and dentin of 3 mm in diameter were obtained from bovine incisors. The specimens were stained for 14 days in broth staining. After staining, the initial color reading was performed by a spectrophotometer CM-2600d (Konica Minolta, Osaka, Japan). Sixty specimens (Subgroups CP) were submitted to whitening (Carbamide Peroxide 10%) for 14 days. Then they were subdivided into 3 subgroups, and were submitted to cycles of staining (5 min) and mouthrinse (2 min) for 12 weeks, with CP-LI: Listerine Whitening Pré- Escovação; CP-PL: Plax Whitening; CP-BP: Bromelain + Papain; CP-DW: deionized water. LI, LP, BP and DW subgroups were submitted to the same cited cycles, but without bleaching before. The color measurements were performed after 4, 8 and 12 weeks of treatment with mouthrinses. Data were collected and subjected to analysis of variance (ANOVA) for repeated measures. The comparison between the subgroups for the evaluation of statistical differences was performed by Tukey test. All tests admitted statistical significance level of 5%. The results showed that the values ΔL*, Δa*, Δb* and ΔE* confirmed bleaching to PC-LI, PC-PL, PC-BP and PC-DW subgroups, after treatment with carbamide peroxide and to CP-LI, CP-PL, LI and PL subgroups, after the staining-mouthrinse cycles. CP-BP and BP subgroups were similar to CP-DW and DW. We conclude, therefore, that the mouthrinse Listerine Whitening presented the highest bleaching effect, followed by mouthrinse Plax Whitening. Both of them were able to maintain the bleaching effect of CP after 12 weeks of dye-rinse cycles. However, none of these rinses was able to produce whitening similar to that evidenced by the Carbamide Peroxide. The mouthrinse containing... / Mestre
179

Influência do tratamento dentinário com Clorexidina, Ácido Hialurônico ou Vitamina C na resistência adesiva e propriedades mecânicas da camada híbrida /

Silva, Patricia Rondon Pleffken da. January 2013 (has links)
Orientador: Maria Amélia Maximo de Araujo / Co-orientador: Maria Filomena Rocha Lima Huhtala / Banca: Miriam Lacalle Turbino / Banca: César Rogério Pucci / Banca: Sérgio Ricardo Garcia Badini / Banca: Ana Paula Martins Gomes / Resumo: O objetivo deste estudo foi avaliar a influencia da Clorexidina, Ácido Hialurônico e Vitamina C na resistência adesiva à dentina e na propriedade mecânica (nanodureza e módulo de elasticidade) da camada híbrida. A dentina superficial de noventa e seis dentes bovinos foi exposta. Os espécimes foram divididos em quatro grupos (n=24) de acordo com o tratamento dentinário: G1 (Controle) - aplicação do sistema adesivo (Adper Single Bond 2); G2 - tratamento com solução de clorexidina a 2% por 1 min + sistema adesivo; G3 - tratamento de solução com Ácido Hialurônico 1% por 1 min + sistema adesivo; G4 - tratamento com solução de Vitamina C (Vit C) 10% por 1 min + sistema adesivo. Após polimerização do sistema adesivo foi aplicado duas camadas de resina composta Filtek 250 (3M ESPE) de forma incremental com auxílio de uma matriz e fotopolimerizada por 20 s cada. Em seguida, os espécimes foram armazenados em água destilada a 37°C por 24 h (n=12) e 6 meses (n=12). Após o período de armazenamento, os espécimes foram seccionados onde se obteve um espécime de aproximadamente 1 mm2 de área. Foram submetidos ao teste de microtração em máquina de ensaio universal (DL-1000, EMIC/10 kgf/ 0,5 mm/min). Cinco espécime de cada grupo armazenado por 6 meses foi submetido ao teste de nanodureza e módulo de elasticidade da camada híbrida. Os dados foram submetidos aos testes estatísticos Anova 2 fatores e Tukey. No grupo após armazenamento 24 h mostraram que os maiores valores foram obtidos nos G1, G2 e G3, mas após 6 meses de armazenamento apenas o G2 e G3 apresentaram os maiores valores. Com relação às propriedades mecânicas o G3 apresentou o maior valor de dureza quando comparado aos demais grupos estudados. Não houve diferença estatística significante quanto ao módulo de elasticidade entre os grupos. Concluimos que a aplicação da clorexidina e ácido hialurônico na dentina foi .... / Abstract: The aim of this study was to evaluate the influence of chlorhexidine, hyaluronic acid and C vitamin C on dentin bond strength and on the hybrid layer mechanical properties. The buccal surface of ninety six extracted bovine teeth was ground to exposure a flat dentin surface. The specimens were divided in four experimental groups (n=24): G1 (Control) - application of the adhesive system (Adper Single Bond 2); G2: dentin treatment with chlorhexidine 2% for 1 min + adhesive system; G3: dentin treatment with hyaluronic acid 1% for 1 min + adhesive system; G4: dentin treatment with C vitamin 10% for 1 min + adhesive system. After polymerization of the adhesive system, two increments of the composite resin, Filtek Z 350 (3M ESPE), were placed on dentin with the aid of a matrix and polymerized for 20 s each. The specimens were stored in distilled water at 37ºC for 24 h (n=12) and 6 months (n=12). They were then sectioned in order to obtain specimens with an area of approximately 1 mm2. They were submitted to microtensile bond strength tests using a universal testing machine (DL- 1000, EMIC/10 kgf/ 0,5 mm/min). One specimen of each of the groups stored for 6 months was submitted to nanohardness and elasticity module tests for the hybrid layer. Data were analyzed by two-way ANOVA and Tukey's test. Tests performed after 24 h showed higher adhesive bond strength for groups G1, G2 and G3, but after six months the highest values were presented by groups G2 and G3. Nanohardness tests revealed greater resistance for G3 compared to the other groups. Modulus of elasticity was found to be the same for all groups. It could be concluded that the application of chlorhexidine and hyaluronic acid on dentin was effective in keeping high bond strength values after 6 months but regarding the hybrid layer only hyaluronic acid increased nanohardness / Doutor
180

Efeito longitudinal de tratamentos de superfície modificados por Nd:YAG laser na permeabilidade dentinária /

Esteves, Stella Renata Machado Silva. January 2013 (has links)
Orientador: Sérgio Eduardo de Paiva Gonçalves / Co-orientador: Maria Filomena Rocha Lima Huhtala / Banca: Ricardo Scarparo Navarro / Banca: Taciana Marco Ferraz Caneppele / Resumo: A hipersensibilidade dentinária acomete grande parte da população e gera muito desconforto. A maioria dos tratamentos baseia-se na utilização de agentes de redução da permeabilidade que tem seu efeito relacionado a fatores individuais e baixa longevidade. O objetivo deste estudo foi avaliar, in vitro, a eficácia e longevidade de tratamentos para redução da permeabilidade dentinária, tais como o flúor, o adesivo e a desproteinização do colágeno, associados ou não ao Nd:YAG laser por meio da movimentação do fluido dentinário medido pela máquina de permeabilidade (Odeme, Brazil). Setenta espécimes de dentina bovina com 6mm de diâmetro e 1 mm de espessura foram divididos em 7 grupos conforme o tratamento realizado. Grupo C: controle, sem tratamento; Grupo F: verniz com flúor; Grupo FL: verniz com flúor + Nd:YAG laser; Grupo A: adesivo Scotchbond Universal; Grupo AL: adesivo + Nd:YAG laser; Grupo D: 10% de NaOCl + adesivo; Grupo DL: 10% NaOCl + adesivo + Nd:YAG laser. Os espécimes tiveram a permeabilidade dentinária medida em 4 momentos: com a presença de smear layer na parte oclusal (Permeabilidade Mínima); depois da aplicação de EDTA por 1 min (Permeabilidade Máxima); após os tratamentos e; após o desafio erosivo/abrasivo, para analisar a efetividade e durabilidade de cada tratamento. Os modelos estatísticos RM ANOVA (2 fatores) e Tukey (α=0,05) foram aplicados. Os tratamentos foram efetivos na redução da permeabilidade com exceção do grupo FL. Os tratamentos associados ao laser tiveram redução significativa da permeabilidade, exceto para o grupo FL; o grupo AL foi o tratamento mais eficaz na análise imediata pós-tratamento, e o grupo DL foi o mais eficaz pós-desafio (longitudinal). Podemos concluir que somente o tratamento DL foi eficaz longitudinalmente / Abstract: Dentin hypersensitivity affects a large population and generates a lot of discomfort. Most treatments are based on the use of agents to reduce permeability with their effect related to individual factors and with low longevity. The aim of this study was to evaluate in vitro the efficacy and longevity of treatments for reducing dentin permeability, such as fluoride, adhesives and collagen deproteinization, associated or not with Nd : YAG laser by measuring the dentinal fluid flow in a permeability machine ( Odeme , Brazil). Seventy bovine dentin specimens of 6mm diameter and 1 mm thickness were divided into 7 groups according to treatment: Group C: control without treatment; Group F: fluoride varnish; Group FL: fluoride varnish + Nd:YAG laser, Group A: Scotchbond Universal, Group AL: adhesive + Nd:YAG laser, Group D: 10 % NaOCl + adhesive; group DL: 10 % NaOCl, adhesive + Nd:YAG laser. The specimens had dentin permeability measured in 4 phases: in the presence of the occlusal smear layer (Minimum Permeability), after EDTA application for 1 min (Maximum Permeability), after the treatments and after erosion / abrasive challenge; in order to analyze the effectiveness and durability of each treatment. RM ANOVA (2 factors) and Tukey (α = 0,05) were applied. Treatments were effective in reducing permeability except for group FL; the laser treatments were associated with significant reduction in permeability, except for the FL group; group AL was the most effective treatment in the immediate post-treatment analysis and; the DL group was the most effective post- challenge (longitudinal). We conclude that only the DL treatment was effective longitudinally / Mestre

Page generated in 0.0759 seconds