• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 839
  • 37
  • 37
  • 37
  • 37
  • 36
  • 29
  • 9
  • 7
  • 6
  • 4
  • 3
  • 3
  • 1
  • 1
  • Tagged with
  • 899
  • 499
  • 251
  • 202
  • 193
  • 178
  • 152
  • 140
  • 140
  • 121
  • 114
  • 97
  • 97
  • 96
  • 94
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
161

Condicionamento com ácido cítrico e os efeitos biológicos na aplicação tópica de bFGF e BMP-7 em células relevantes para a regeneração periodontal

Rocha, Fernanda Regina Godoy [UNESP] 27 March 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-03-27Bitstream added on 2014-06-13T20:17:45Z : No. of bitstreams: 1 rocha_frg_me_arafo.pdf: 2074950 bytes, checksum: 44b81ca3437b0380ff6a9431b98cf128 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A regeneração periodontal ainda representa um importante desafio, devido a limitações na efetividade e imprevisibilidade das abordagens clínicas. O condicionamento radicular e a utilização de mediadores biológicos, como os fatores de crescimento, são duas das técnicas que tem sido estudadas para esta finalidade; também tem sido proposta a combinação de ambas. Foi avaliado in vitro o efeito do condicionamento ácido da dentina na liberação de bFGF e BMP-7 aplicados topicamente de forma isolada ou associados, além da influência de tais tratamentos na expressão de genesalvo relacionados ao metabolismo de tecido conjuntivo mineralizado e não mineralizado em três tipos celulares relevantes para o processo regenerativo no microambiente periodontal. Espécimes de dentina bovina foram subdivididos em dois grupos: não condicionados e condicionados com ácido cítrico 25% durante 3 minutos. bFGF recombinante humano (10 e 50 ng), BMP-7 (100 e 300 ng) e associação bFGF/BMP-7 (50 ng e 100 ng, respectivamente) foram suspendidos em 50 μL de meio de cultura e aplicados topicamente sobre a dentina. A liberação de fatores de crescimento aplicados topicamente sobre a dentina condicionada e não condicionada foi determinada por meio de ELISA. Linhagens celulares de camundongos – fibroblastos do ligamento periodontal, cementoblastos e células do estroma ósseo – foram plaqueadas sobre os espécimes de dentina com e sem condicionamento ácido prévio, tratados ou não com os fatores de crescimento. Após 24 horas, as células aderidas sobre as amostras de dentina foram coletadas, o RNA total extraído e a expressão gênica de colágeno 1-alfa1, fibronectina e Runx2 foi avaliada por RTqPCR. Os resultados encontrados neste estudo indicam que os fatores de crescimento são retidos pela dentina após aplicação tópica... / Periodontal regeneration still poses a challenge both in terms of predictability and magnitude of effect. Chemical root conditioning and the use of biological mediators are two strategies studied to improve the results of regenerative therapies. The objective of this study was to determine the effect of acid conditioning of dentin on the release of topically applied bFGF and BMP-7, isolated or associated. We also evaluated the impact of such treatment in the expression of target genes related to the metabolism of mineralized connective tissue and non-mineralized in three cell types relevant for the regenerative process in the periodontal microenvironment. Dentin specimens, which were obtained from bovine teeth, were divided into two groups: non-conditioned and conditioned with 25% citric acid for 3 minutes. Human growth factors produced by recombinant DNA technology were diluted in 50 mL of culture medium and topically applied on the dentin in the following amounts: recombinant human bFGF (10 and 50 ng), BMP-7 (100 and 300 ng) and associated bFGF/BMP-7 (50 ng and 100 ng, respectively). The released of growth factor topically applied on the conditioned and non-conditioning dentin samples was determined by ELISA. Murine cell lines - periodontal ligament fibroblasts, cementoblasts and bone marrow stromal cells - were grown on dentin specimens with and without prior acid conditioning and application of growth factors. After 24 hours, the cells adhered on the samples of dentin were collected, total RNA extracted and gene expression of collagen 1-alpha 1, fibronectin and Runx2 was determined by RT-qPCR. The results of this study indicate that: growth factors are retained by dentin after topical application and that the peak release occurs in two hours; the conditioning of dentin with citric acid favored the retention of topically applied growth... (Complete abstract click electronic access below)
162

Avaliação de LEDs de alta intensidade quanto à eficiência de polimerização de resina composta e variação de temperatura na dentina bovina

Mollica, Fernanda Brandão [UNESP] 29 June 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-06-29Bitstream added on 2014-06-13T20:31:06Z : No. of bitstreams: 1 mollica_fb_me_sjc.pdf: 859430 bytes, checksum: 9995882b109a407d775d587ef3cb2f1c (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este estudo teve por objetivo avaliar a eficiência de polimerização de uma resina composta (RC) e a variação de temperatura na dentina bovina, empregando aparelhos de Diodo Emissor de Luz (LED) de alta intensidade em comparação a um aparelho de Quartzo-Halogênio-Tungstênio (QTH). Os aparelhos utilizados foram: Curing Light XL 3000 (3M, 600 mW/cm2), LED SmartLite PS (Dentsply, 950 mW/cm2) e LED Radii (SDI, 1400 mW/cm2) e a RC, a Esthet X (Dentsply). Para o teste de microdureza Vickers, foram confeccionados 84 corpos-de-prova (2 mm x 5 mm) em matriz de teflon bipartida, variando-se o tempo de exposição em 10, 20 e 40 s, sendo que o aparelho XL 3000 foi utilizado para o grupo controle apenas pelo tempo de 40 s. Após 24 h, realizou-se o teste de microdureza no topo e na base dos corpos-de-prova com carga de 50 g e duração de 15 s. Para a medida da variação de temperatura ocasionada pelos aparelhos, foram utilizadas 45 fatias de dentina bovina de 0,7 mm de espessura e termopar tipo T conectado a um sistema de aquisição de dados ADS 2000 IP (Lynx Tecnologia). As fatias foram divididas em três grupos, sendo a variação de temperatura medida em três etapas: 1) durante a fotopolimerização do adesivo (10 s); 2) durante a fotopolimerização da RC (40 s) e 3) após 24 h (40 s). Os valores de microdureza do topo e da base e os dados de temperatura foram submetidos ao teste ANOVA de medidas repetidas e aos testes de Tukey e Dunnet (p=5%). Os resultados revelaram diferença estatística significante de microdureza no topo e na base quando se utilizaram ambos os LEDs por 10 s em relação ao uso do XL 3000 por 40 s, não havendo diferenças estatísticas entre os grupos com os tempos de 20 s e 40 s. A utilização do LED Radii pelos tempos de 10 e 20 s não foi suficiente... / The aim of this study was to evaluate the efficiency of polymerization of a resin composite and the temperature variation in bovine dentine, using two curing units of Light Emitting Diode (LED) of high intensity in comparison to a Quartz-Halogen-Tungsten device (QTH). The light curing units used were: Curing Light XL 3000 (3M, 600 mW/cm2), LED SmartLite PS (Dentsply, 950 mW/cm2) and LED Radii (SDI, 1400 mW/cm2) and the resin composite, Esthet X (Dentsply). For the test of Vickers microhardness, 84 specimens (2 mm X 5 mm) were prepared in bipartite matrix of teflon, varying the time of exposition in 10, 20 and 40 s. The curing unit XL 3000 was used for the control group for 40 s. After 24 h, the microhardness test was made on the top and base of the specimens with 50 g of load and 15 s of duration. For the temperature variation measurement caused by the different curing units, 45 slices of bovine dentine of 0.7 mm thickness and a thermocouple type T hardwired to a system of data acquisition ADS 2000 IP (Lynx Technology) were used. The slices were divided in three groups and the temperature variation was measured in three stages: 1) during the adhesive photopolymerization (10 s); 2) during resin composite photopolymerization (40 s) and 3) after 24 h (40 s). The values of microhardness of the top and the base and the data of temperature variation were submitted to ANOVA of repeated measures test and to the tests of Tukey and Dunnet (p=5%). The results showed statistical significant difference of microhardness for the top and base values when both LEDs were used for 10 s in relation to the use of XL 3000 for 40 s, but no statistical differences were found between the groups when the exposition time was 20 s and 40 s. The use of LED Radii for 10 s and 20 s was not enough to equal statistically ... (Complete abstract, click electronic access below)
163

Efeito de um primer experimental contendo carbodiimida na atividade de metaloproteinases, degradação do colágeno e da união resina-dentina

Delgado, Cláudia Cristina [UNESP] 14 September 2015 (has links) (PDF)
Made available in DSpace on 2016-12-09T13:52:19Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-09-14. Added 1 bitstream(s) on 2016-12-09T13:55:23Z : No. of bitstreams: 1 000867016_20170914.pdf: 536998 bytes, checksum: 0606d3388abd5fb14a618e42dbb31b2d (MD5) Bitstreams deleted on 2017-09-15T13:13:30Z: 000867016_20170914.pdf,. Added 1 bitstream(s) on 2017-09-15T13:14:17Z : No. of bitstreams: 1 000867016.pdf: 971975 bytes, checksum: 1eb5675eaa1fbd94d09a21501d6368f8 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Objetivo: Avaliar o efeito da aplicação de um primer experimental contendo carbodiimida (EDC) na atividade total de metaloproteinases (MMPs), na degradação do colágeno dentinário e na estabilidade longitudinal da união resina-dentina. Métodos: Foram desenvolvidos dois estudos para responder aos objetivos do trabalho. Estudo 1:Cem espécimes de dentina (1x1x6mm) foram obtidos de molares permanentes humanos hígidos. Cinquenta espécimes foram condicionados com ácido fosfórico 37% e tratados por 60s com (n=10): água deionizada (controle), EDC 0,5 mol/L, primer experimental (PE), primer experimental com EDC (PE+EDC) ou primer do sistema Scotchbond MP (SBMP). Após lavagem, os espécimes foram submetidos a um teste colorimétrico (SenSolyte) para a análise da atividade total de MMP. Outros 20 espécimes foram submetidos a um protocolo de indução de cárie. Esses e os demais 20 espécimes mantidos hígidos foram completamente desmineralizados em ácido fosfórico 10% por 18h e tratados como descrito acima. Os espécimes foram armazenados em solução semelhante à saliva por 15 dias a 37ºC, quando a saliva foi coletada para a quantificação de hidroxiprolina (HYP). Os dados foram submetidos aos testes ANOVA e Tukey (p<0,05). Estudo 2: Superfícies planas de dentina foram produzidas em 32 molares permanentes hígidos. Os dentes foram condicionados por 15s e tratados (n=8) como descrito no estudo 1, com exceção da água deionizada.Após o tratamento, o adesivo do sistema SBMP foi aplicado sobre todos os dentes seguido da construção de um bloco em resina composta. Os dentes foram seccionados em espécimes com área de secção transversal de 0,81 mm2, os quais foram armazenados em solução semelhante à saliva por 24h ou 6 meses previamente ao ensaio de microtração. Os dados em MPa foram submetidos aos testes de ANOVA a dois critérios fixos...(Resumo completo, clicar acesso eletrônico abaixo) / Objective: To evaluate the effect of an experimental primer containing EDC on the total matrix metalloproteinases (MMPs) activity, collagen degradation and resin-dentin bond stability. Methods: Two studies were developed to answer to the objectives of this dissertation. Study 1: One hundred dentin beams (1x1x6 mm) were obtained from sound human permanent molars. Fifty specimens were acid-etched with 37% phosphoric acid and treated for 60s with (n=10): deionized water (control), 0.5 mol/L EDC, experimental primer (EP), experimental primer with 0.5 mol/L EDC (EP+EDC) or Scotchbond MP primer (SBMP). After rinsing, the total MMP activity was assessed by a colorimetric assay (SenSolyte). Additionally, 20 specimens were subjected to a caries-inducing protocol. These and the remaining 20 sound specimens were completely demineralized in 10% phosphoric acid for 18h. The specimens were treated as mentioned above and stored in saliva-like solution for 15 days at 37°C. After this period, the saliva was collected for the quantification of hydroxyproline (HYP) release. MMP activity and HYP release were submitted to ANOVA and Tukey tests (p<0.05). Study 2: Flat dentin surfaces were obtained from 32 sound third molars. The dentin was acid-etched for 15s and treated (n=8) as described in the study 1, except for deionized water. After treatment, the bond of SBMP was applied to all teeth and resin blocks were constructed. After 24h, the teeth were cut into specimens with 0.81 mm2 of cross-sectional area, which were stored in saliva-like solution for 24h or 6 mo prior to microtensile testing. The bond strength values (MPa) were submitted to two-way ANOVA, Tukey and chi-square (χ2) tests (p<0.05). Types of fractures were descriptively analyzed. Results: All treatments reduced the activity of MMPs, however, 0.5 mol/L EDC (92%) and the EP+EDC (78%) were the most effective...(Complete abstract electronic access below) / FAPESP: 2012/088866-4
164

Biomodificação do colágeno dentinário por Cross-Linkers: efeito na rigidez do colágeno e na longevidade da união resina-dentina produzida pela técnica Dry-Bonding

Bianchi, Luciana [UNESP] 24 November 2015 (has links) (PDF)
Made available in DSpace on 2016-12-09T13:52:20Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-11-24. Added 1 bitstream(s) on 2016-12-09T13:55:24Z : No. of bitstreams: 1 000871154.pdf: 2451026 bytes, checksum: e29c010991d3c7a6ad57c9b8e0e38c24 (MD5) / Os objetivos desse estudo foram investigar o efeito da aplicação de diferentes agentes promotores de ligações cruzadas (cross-linkers) sobre (1) a rigidez do colágeno dentinário e (2) sobre a degradação da união resinadentina produzida pela técnica dry-bonding. Para responder ao primeiro objetivo, 40 discos de dentina com 0,3 mm de espessura foram obtidos de pré-molares hígidos. Após completa desmineralização em ácido fosfórico 10%, os discos foram aleatoriamente divididos em 5 grupos (n=8): água deionizada (controle), carbodiimida (EDC) 0,5 mol/L, proantocianidina (PA) 5% ou glutaraldeído (GA) 5% ou 25%. Os discos permaneceram imersos nas soluções por 60s. A rigidez do colágeno foi indiretamente avaliada com base na contração após desidratação, por meio de transformador linear diferencial variável (LVDT). Para responder ao segundo objetivo, 64 pré-molares humanos hígidos foram desgastados para remoção total do terço coronário, obtendo desta forma superfícies planas de dentina. Estas foram condicionadas com ácido fosfórico a 37% por 15s, seguido do tratamento com as mesmas soluções descritas acima (n=16), exceto para o GA 25%. Após um tempo pré-determinado de tratamento, a dentina foi mantida úmida em metade dos dentes (n=8), e desidratada com jatos de ar nos dentes restantes (n=8). Em seguida, em todos os dentes, foi aplicado o adesivo Prime & Bond 2.1 e foi construído um bloco de resina. Espécimes de 0,81 mm² de área adesiva foram submetidos ao ensaio mecânico de microtração, após 24h ou 6 meses de envelhecimento em saliva artificial. Também foram analisados os tipos de fratura após o teste de microtração e oito espécimes por grupo/período de envelhecimento foram preparados para análise da nanoinfiltração. Para ambos os experimentos, os dados foram submetidos aos testes de ANOVA e Tukey (p<0,05). Na ausência de tratamento...(Resumo completo, clicar acessO letrônico abaixo) / The aims of this study were to investigate the effect of the application of cross-linkers on (1) the stiffness of dentin collagen and (2) the resin-dentin bond degradation produced by the dry-bonding technique. To respond the first objective, forty 0.3 mm-thick dentin disks were obtained from sound premolars. After complete demineralization in 10% phosphoric acid, the discs were randomly divided into 4 groups according to the treatment (n=8): deionized water (control), 0.5 mol/L carbodiimide (EDC), 5% proanthocyanidin (PA) and 5% or 25% glutaraldehyde (GA). The discs were immersed in the solutions for 60s. Collagen stiffness was assessed indirectly based on the shrinkage after dehydration, measured in a linear variable differential transformer (LVDT). For second objective, flat dentin surfaces were produced in 64 sound pre-molars. The dentin was etched with phosphoric acid 37% for 15s, followed by treatment with the same solution described previously (n=16), except for the 25%GA. After the 60s treatment, the dentin was kept moist in half of the teeth (n=8) and dehydrated by air jets in the remaining teeth (n=8). Prime & Bond 2.1 adhesive was applied in all teeth followed by the built up of a composite block. Specimens of 0.81mm² adhesive area were obtained for the microtensile bond strength test, performed after 24h or 6 months of aging in saliva-like solution. After the mechanical test, the failure type was analyzed. Eight specimens by group were prepared for nanoleakage analysis. For both experiments, data were submitted to ANOVA and Tukey tests (p<0.05). In the absence of treatment with cross-linkers (control group), the percentage of shrinkage of the dentin matrix was 60%. Only EDC (23.9%) and glutaraldehyde 25% applied for 10 min (21.7%) were able to significantly reduce dentin shrinkage after dehydration. The highest bond strength values were found for EDC and 10% GA...(Complete abstract eletronic access below)
165

Fnfluência de agentes antiproteolíticos na resistência de união da interface dentina, adesivo e cimento resinoso / Influence of antiproteolytic agents on dentin, adhesive and luting cement interface

Kamozaki, Maria Beatriz Beber [UNESP] 02 December 2016 (has links)
Submitted by Maria Beatriz Beber Kamozaki null (maria.kamozaki@ict.unesp.br) on 2017-01-20T12:46:41Z No. of bitstreams: 1 Tese Final impressão.pdf: 5601023 bytes, checksum: c194d9b1ef2e3281f88141631e69352d (MD5) / Approved for entry into archive by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br) on 2017-01-24T17:01:04Z (GMT) No. of bitstreams: 1 kamozaki_mbb_dr_sjc.pdf: 5601023 bytes, checksum: c194d9b1ef2e3281f88141631e69352d (MD5) / Made available in DSpace on 2017-01-24T17:01:04Z (GMT). No. of bitstreams: 1 kamozaki_mbb_dr_sjc.pdf: 5601023 bytes, checksum: c194d9b1ef2e3281f88141631e69352d (MD5) Previous issue date: 2016-12-02 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste trabalho, foi avaliar a influência de agentes antiproteolíticos, imediatamente e após 12 meses, na cimentação adesiva. Foram utilizadas as porções coronárias de 64 molares humanos hígidos. As amostras foram divididas aleatoriamente em 4 grupos, de acordo com o tratamento da dentina: CT (grupo controle); CXL (grupo clorexidina); EGCG (grupo epigalocatequina-3-galato); AT (grupo antocianina). Para a restauração, foram confeccionados cilindros em resina composta Filtek Z350 XT. Após o condicionamento ácido da dentina, as soluções antiproteolíticas foram aplicadas e mantidas sobre a superfície por 60 s, em seguida as restaurações foram cimentadas às amostras com o adesivo Adper Single Bond 2 + cimento resinoso Variolink II. Todos os grupos foram subdivididos de acordo com o tempo de armazenamento em água destilada para o ensaio mecânico: I (Imediato = após 24 h); A (Armazenado = após 12 meses). As amostras foram cortadas em palitos e submetidas ao teste de microtração. Os dados obtidos foram submetidos ao teste de ANOVA a 2 fatores, seguido do teste de Tukey (α=5%). Foram encontradas diferenças para os fatores Tratamento (p=0,03) e Armazenamento (p=0,00). Os valores em MPa de média e desvio padrão para interação entre os fatores Tratamento X Armazenamento, foram: CT.I: 42.56 (±7,60) A; EGCG.I: 39.6 (±8,99) A; CLX.I: 39.37 (±9,44) A; AT.I: 38.69 (±8,65) A; CT.A: 31.85 (±6,96) A; AT.A: 31.29 (±4,89) AB; EGCG.A: 30.94 (±9,91) AB; CLX.A: 18.68 (±4,53) B. Foram confeccionadas duas amostras adicionais de cada grupo para avaliação descritiva da microdureza knoop de subsuperfície e avaliação qualitativa da interface adesiva em MEV. Conclui-se que as soluções de EGCG e AT foram capazes de manter a estabilidade da resistência de união após 12 meses de armazenamento e que a solução de CLX afetou negativamente os valores de resistência de união comparado aos demais subgrupos. / The aim of this study was to evaluate immediately and longitunally the antiproteolytic agent influence to adhesive cementation. Were used 64 coronary portion of sound human molars. The samples were divided into 4 groups according to the dentin treatment: CG (Control group); CLX (chlorhexidine group); EGCG (epigallocatechin-3-gallate group); AT (anthocyanin group). Cylindrical composite blocks were prepared using a resin composite Filtek Supreme for the restorations. The solutions were applied on the acid-etched dentin and were kept for 60 s. The resin composite blocks were cemented with the adhesive system Adper Single Bond 2 + resin cement Variolink II. All groups were subdivided according to the storage time in distilled water for mechanical testing: I (Immediate = after 24 h); S (Stored = after 12 months). Samples were cut into beams and tested in a universal testing machine at a crosshead speed of 0.5 mm/min until failure. The data were submitted to two-way ANOVA, followed by the Tukey test (α = 5%). Significant differences were found for the Treatment factor (p = 0.03) and Storage factor (p = 0.00). The mean values and standard deviation for interaction between the factors Treatment X Storage, were CG.I: 42.56 (± 7.60) A; EGCG.I: 39.6 (± 8.99) A; CLX.I: 39.37 (± 9.44) A; AT.I: 38.69 (± 8.65) A; CG.S: 31.85 (± 6.96) A; AT.S: 31.29 (± 4.89) AB; EGCG.S: 30.94 (± 9.91) AB; CLX.S: 18.68 (± 4.53) B. Two additional samples from each group were confectioned to descriptive analyses of microhardness knoop of dentin subjacent to the bonding interface and a qualitative interface evaluation with SEM (scanning electron microscope). It can be conclude that EGCG and AT solutions were able to maintain the bond strength stability after 12 months of storage and CLX solution adversely affect the bond strength values compared to other subgroups.
166

Avaliação da eficácia do etanol na resistência de união à dentina utilizando adesivo convencional e autocondicionante sob envelhecimento / Evaluation of the ethanol effectiveness on bond strength to dentin using etch-and-rinse and self-etching adhesives after aging

Souza, Mauricio Yugo de [UNESP] 09 December 2016 (has links)
Submitted by MAURICIO YUGO DE SOUZA null (maauyugo@hotmail.com) on 2017-01-24T20:58:37Z No. of bitstreams: 1 Dissertação Mauricio Yugo.pdf: 1833665 bytes, checksum: 37651512f33725d56391f20be6e23455 (MD5) / Approved for entry into archive by LUIZA DE MENEZES ROMANETTO (luizamenezes@reitoria.unesp.br) on 2017-01-26T16:33:36Z (GMT) No. of bitstreams: 1 souza_my_me_sjrp.pdf: 1833665 bytes, checksum: 37651512f33725d56391f20be6e23455 (MD5) / Made available in DSpace on 2017-01-26T16:33:36Z (GMT). No. of bitstreams: 1 souza_my_me_sjrp.pdf: 1833665 bytes, checksum: 37651512f33725d56391f20be6e23455 (MD5) Previous issue date: 2016-12-09 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar o efeito do etanol na longevidade de união de diferentes modos de aplicação do sistema adesivo ao substrato dentinário bovino, através do teste de microtração. Foram utilizados 80 incisivos bovinos, os quais tiveram a superfície dentinária da face vestibular exposta e a padronização da smear layer. Após a padronização, os espécimes foram divididos aleatoriamente em 2 grupos, Grupo Com Etanol (GE) e Grupo Sem Etanol (GS) e após, subdivididos de acordo com a forma de aplicação do sistema adesivo, Condicionamento Ácido Convencional (GEC, GSC) e Autocondicionante (GEA, GSA). Sobre a superfície tratada foram confeccionados blocos de resina com auxílio de matriz de silicone e armazenados em água deionizada a 37 ºC, por um período de 48 h. Após a cura da resina, metade dos espécimes foi submetida ao envelhecimento termomecânico resultando nos seguintes grupos (n= 10): GEC sem Envelhecimento (GECSE), GEC Envelhecido (GECE), GSC Sem Envelhecimento (GSCSE), GSC Envelhecido (GSCE), GEA Sem Envelhecimento (GEASE), GEA Envelhecido (GEAE), GSA Sem Envelhecimento (GSASE) e GSA Envelhecido (GSAE). Foram obtidos palitos resina/dentina com área adesiva medindo aproximadamente 1x1 mm, e submetidos ao teste de microtração em máquina de ensaios Universal DL-200MF (EMIC). Os dados foram analisados pelos testes ANOVA a três fatores e Tukey (α = 5%). Houve interação entre os três fatores (p = 0,0003). O modo de aplicação foi semelhante, exceto para o GSAE que foi maior que o GSCE. A utilização do etanol resultou em valores superiores de microtração, exceto para GECSE que foi similar a GSCSE. Para os grupos envelhecidos, os valores foram inferiores, exceto quando da utilização do etanol, no qual os resultados não foram influenciados pelo envelhecimento. Conclui-se que utilização do etanol resultou em valores de microtração superiores, principalmente quando associado ao envelhecimento. O modo de aplicação do adesivo de forma geral não influenciou nos resultados. / The aim of this study was to evaluate the effect of ethanol on the longevity on adhesion by different application ways of adhesive system to bovine dentin substrate, through the microtensile test. Eighty bovine incisors were used, which had buccal dentin exposed and the standardization of smear layer obtained by sandpaper polishing (600 SiC, Fepa-P). After standardization, the specimens were randomly divided into 2 groups, With Ethanol Group (GE) and No Ethanol Group (GS) and further, subdivided according to the application ways into: Conventional Acid conditioning (GEC, GCH) and self-etching (GEA, GSA). Resin blocks were built over the treated surface using a silicon mold and specimens were stored in deionized water at 37ºC for 48 hours. After resin lightcuring, half of the specimens was subjected to thermomechanical aging resulting in the following groups (n = 10): GEC No Aging (GECSE), GEC Aged (GECE), GSC No Aging (GSCSE), GSC Aged (GSCE), GEA No Aged (GEASE), GEA Aged (GEAE), GSA No Aging (GSASE) e GSA Aged (GSAE). Resin/Dentin sticks measuring approximately 1x1 mm were obtained and subjected to microtensile test in universal testing machine Universal DL-200MF (EMIC). Data were analyzed by three-way ANOVA and Tukey tests (α = 5%). There was interaction between the three factors (p = 0.0003). The application way was similar except for GSAE which was highest than GSCE. The use of ethanol resulted in higher values of microtensile except for GECSE which was similar to GSCSE. For the aged group, the values were below, except when the use of ethanol, in which the results were not affected by aging. It is concluded that use of ethanol resulted in higher microtensile bond strength values, especially when associated with aging. The application way of universal adhesive system did not influence the results.
167

Biomodificação do colágeno dentinário por Cross-Linkers: efeito na rigidez do colágeno e na longevidade da união resina-dentina produzida pela técnica Dry-Bonding /

Bianchi, Luciana. January 2015 (has links)
Orientador: Fernanda Gonçalves Basso / Banca: Elisa Maria Aparecida Giro / Banca: Rita de Cássia Loiola Cordeiro / Banca: Hérica Adad Ricci / Banca: Adriano Fonseca de Lima / Resumo: Os objetivos desse estudo foram investigar o efeito da aplicação de diferentes agentes promotores de ligações cruzadas (cross-linkers) sobre (1) a rigidez do colágeno dentinário e (2) sobre a degradação da união resinadentina produzida pela técnica dry-bonding. Para responder ao primeiro objetivo, 40 discos de dentina com 0,3 mm de espessura foram obtidos de pré-molares hígidos. Após completa desmineralização em ácido fosfórico 10%, os discos foram aleatoriamente divididos em 5 grupos (n=8): água deionizada (controle), carbodiimida (EDC) 0,5 mol/L, proantocianidina (PA) 5% ou glutaraldeído (GA) 5% ou 25%. Os discos permaneceram imersos nas soluções por 60s. A rigidez do colágeno foi indiretamente avaliada com base na contração após desidratação, por meio de transformador linear diferencial variável (LVDT). Para responder ao segundo objetivo, 64 pré-molares humanos hígidos foram desgastados para remoção total do terço coronário, obtendo desta forma superfícies planas de dentina. Estas foram condicionadas com ácido fosfórico a 37% por 15s, seguido do tratamento com as mesmas soluções descritas acima (n=16), exceto para o GA 25%. Após um tempo pré-determinado de tratamento, a dentina foi mantida úmida em metade dos dentes (n=8), e desidratada com jatos de ar nos dentes restantes (n=8). Em seguida, em todos os dentes, foi aplicado o adesivo Prime & Bond 2.1 e foi construído um bloco de resina. Espécimes de 0,81 mm² de área adesiva foram submetidos ao ensaio mecânico de microtração, após 24h ou 6 meses de envelhecimento em saliva artificial. Também foram analisados os tipos de fratura após o teste de microtração e oito espécimes por grupo/período de envelhecimento foram preparados para análise da nanoinfiltração. Para ambos os experimentos, os dados foram submetidos aos testes de ANOVA e Tukey (p<0,05). Na ausência de tratamento...(Resumo completo, clicar acessO letrônico abaixo) / Abstract: The aims of this study were to investigate the effect of the application of cross-linkers on (1) the stiffness of dentin collagen and (2) the resin-dentin bond degradation produced by the dry-bonding technique. To respond the first objective, forty 0.3 mm-thick dentin disks were obtained from sound premolars. After complete demineralization in 10% phosphoric acid, the discs were randomly divided into 4 groups according to the treatment (n=8): deionized water (control), 0.5 mol/L carbodiimide (EDC), 5% proanthocyanidin (PA) and 5% or 25% glutaraldehyde (GA). The discs were immersed in the solutions for 60s. Collagen stiffness was assessed indirectly based on the shrinkage after dehydration, measured in a linear variable differential transformer (LVDT). For second objective, flat dentin surfaces were produced in 64 sound pre-molars. The dentin was etched with phosphoric acid 37% for 15s, followed by treatment with the same solution described previously (n=16), except for the 25%GA. After the 60s treatment, the dentin was kept moist in half of the teeth (n=8) and dehydrated by air jets in the remaining teeth (n=8). Prime & Bond 2.1 adhesive was applied in all teeth followed by the built up of a composite block. Specimens of 0.81mm² adhesive area were obtained for the microtensile bond strength test, performed after 24h or 6 months of aging in saliva-like solution. After the mechanical test, the failure type was analyzed. Eight specimens by group were prepared for nanoleakage analysis. For both experiments, data were submitted to ANOVA and Tukey tests (p<0.05). In the absence of treatment with cross-linkers (control group), the percentage of shrinkage of the dentin matrix was 60%. Only EDC (23.9%) and glutaraldehyde 25% applied for 10 min (21.7%) were able to significantly reduce dentin shrinkage after dehydration. The highest bond strength values were found for EDC and 10% GA...(Complete abstract eletronic access below) / Doutor
168

Estudo longitudinal da resistência adesiva aos substratos dentários de sistemas adesivos associados ou não ao Nd:YAG Laser /

Barcellos, Daphne Camara. January 2013 (has links)
Orientador: Sérgio Eduardo de Paiva Gonçalves / Banca: César Rogério Pucci / Banca: Ricardo Scarparo Navarro / Banca: Alessandra Nara de Souza Rastelli / Banca: Maria Filomena Rocha Lima Huhtala / Resumo: O objetivo deste estudo foi avaliar a resistência de união dos sistemas adesivos Clearfil SE Bond (CL) e Single Bond (SB) ao esmalte e dentina, em função da associação ou não do Nd:YAG Laser e do tempo de armazenagem (24 h e 12 meses). Foram utilizados 240 dentes bovinos com superfícies de esmalte ou dentina planificadas, que foram divididos em 4 grupos (n = 15) para cada substrato, de acordo com o sistema adesivo e a técnica: G1 (Controle) - CL + fotopolimerização; G2 (Controle) - SB + fotopolimerização; G3 (Experimental/Laser) - CL + Nd:YAG Laser + fotopolimerização; G4 (Experimental/Laser) - SB + Nd:YAG Laser + fotopolimerização. Para o esmalte, foi utilizada a densidade de energia = 174,16 J/cm2 e, para a dentina, a densidade de energia = 149,28 J/cm2 do Nd:YAG Laser. Foram confeccionadas restaurações de resina composta Z-350. Após armazenagem de 24 h ou 12 meses em água destilada à 37º C, foram realizadas as secções nos dentes para obtenção de amostras com área adesiva de aproximadamente 1 mm2, seguido de teste de microtração. Para cada substrato, foi realizado o teste estatístico ANOVA três fatores (Sistema adesivo X Técnica X Tempo de armazenagem), seguido do Teste de Tukey (α = 5%). Foi realizada MEV para análise complementar da interface adesiva. Para o esmalte, foram observadas diferenças significantes para a interação entre Tipo de adesivo X Técnica e Técnica X Tempo de armazenagem. Os valores de média em MPa (±Desvio-padrão) para a interação entre Tipo de adesivo X Técnica: SB/Controle = 35,78 (± 6,04)a; SB/Laser = 26,40 (± 7,25)b; CL/Controle = 26,32 (± 5,71)b; CL/Laser = 23,90 (± 7,49)b. Os valores de média em MPa (±Desvio-padrão) para a interação entre Técnica X Tempo de armazenagem: Controle/24h = 32,58 (± 6,49)a; Controle/12 meses = 29,52 (± 8,38)a; Laser/24h = 29,37 (± 5,71)a; Laser/12 meses = 20,92 (± 6,5)b. Para... / Abstract: The aim of this study was to evaluate the bond strength of Clearfil SE Bond (CL) and Single Bond (SB) adhesive systems to enamel and dentin, depending on whether association with Nd: YAG Laser and storage time (24 h and 12 months). A total of 240 bovine teeth with enamel or dentin surfaces planned were prepared, which were divided into 4 groups (n = 15) for each substrate, according to the adhesive system and technique: G1 (control) - CL + photopolymerization; G2 (Control) - SB + photopolymerization; G3 (Experimental/Laser) - CL + Nd: YAG Laser + photopolymerization; G4 (Experimental/Laser) - SB + Nd: YAG Laser + photopolymerization. To the enamel, was used energy density = 174.16 J/cm2 and for dentine, energy density = 149.28 J/cm2 of Nd: YAG Laser. Composite restorations were fabricated (Filtek Z-350). After storage for 24 h or 12 months in distilled water at 37 ° C, the sections were performed on teeth to obtainment sticks with an area of about 1 mm2 adhesive interface, followed by microtensile test. For each substrate, we performed a three-way ANOVA (adhesive X Technical X Storage time), followed by the Tukey test (α = 5%). SEM analysis was performed to supplement the adhesive interface. For enamel, significant differences were observed for interaction factors Adhesive X Technique and Technique X Storage time. The mean values in MPa (± standard deviation) for interaction factor Adhesive X Technique: SB / Control = 35.78 (± 6.04) a; SB / Laser = 26.40 (± 7.25) b, CL / Control = 26.32 (± 5.71) b, CL / Laser = 23.90 (± 7.49) b. The mean values in MPa (± standard deviation) for interaction factor Technique X Storage time: Control/24h = 32.58 (± 6.49)a; Control/12 months = 29.52 (± 8.38 )a; Laser/24h = 29.37 (± 5.71)a; Laser/12 months = 20.92 (± 6.5)b. For dentin, significant differences were observed for interaction factors Technique X Storage time and Adhesive X Technique ... / Doutor
169

Análise da resistência de união à dentina humana submetida ao condicionamento total sob pressão pulpar simulada e armazenamento em etanol 75% /

Holleben, Priscila. January 2013 (has links)
Orientador: Sérgio Eduardo de Paiva Gonçalves / Co-orientador: Maria Filomena Rocha Lima Huhtala / Banca: Linda Wang / Banca: César Rogério Pucci / Resumo: A degradação hidrolítica da interface adesiva é o fator mais crítico na longevidade dos procedimentos restauradores. O objetivo deste estudo, in vitro, foi avaliar, por meio do teste de microtração, a resistência de união do sistema adesivo Scotchbond Universal (SU, 3M ESPE) à dentina humana, submetida à simulação da pressão pulpar e ao armazenamento em água deionizada ou etanol 75% por 1 dia, 10 dias e 30 dias. O sistema adesivo foi aplicado de acordo com a técnica do condicionamento total e sob a simulação de 0 ou 15 cm de H2O de pressão pulpar (durante todo o procedimento restaurador). Foram utilizados 60 terceiros molares humanos divididos em 4 grupos: G1) SU aplicado sem simulação da pressão pulpar (0 cm H2O) e armazenado em água deionizada; G2) SU aplicado sem simulação da pressão pulpar (0 cm H2O) e armazenado em etanol 75%; G3) SU aplicado com simulação da pressão pulpar (15 cm H2O) e armazenado em água deionizada; G4) SU aplicado com simulação da pressão pulpar (15 cm H2O) e armazenado em etanol 75%. Os espécimes foram restaurados com a resina composta Filtek Z350 XT (3M ESPE). Após 48 h em água deionizada a 37ºC, os espécimes foram seccionados para a obtenção de palitos com área adesiva de aproximadamente 1 mm2, que foram submetidos ao teste de microtração após mais 1 dia, 10 dias ou 30 dias de armazenamento em água deionizada ou etanol 75%. A variação da resistência de união foi analisada pelos testes estatísticos ANOVA 3-fatores e Tukey (5% de significância). Todas as variáveis experimentais - pressão pulpar (p=0,0007), meio de armazenamento (p=0,0006) e tempo (p=0,0033) - tiveram influência estatisticamente significante sobre a resistência adesiva (p<0,05). O grupo restaurado sem pressão pulpar e armazenado em água por 1 dia apresentou a maior média (35,26  4,63 A), que diferiu estatisticamente dos grupos restaurado... / Abstract: The hydrolytic degradation of adhesive interface is the most critical factor affecting the longevity of restorative procedures. The aim of this in vitro study was to evaluate the microtensile bond strength of Scotchbond Universal Adhesive (SU, 3M ESPE) to human dentin, submitted to simulated pulpal pressure and stored in either deionized water or 75% ethanol for 1 day, 10 days and 30 days. The adhesive system was applied according to the total-etch technique and under the simulation of either 0 or 15 cm of H2O pressure (during all the restorative procedure). Sixty human third molars were used and divided into 4 groups: G1) SU applied without pulpal pressure (0 cm H2O) and stored into deionized water; G2) SU applied without pulpal pressure (0 cm H2O) and stored into 75% ethanol; G3) SU applied with pulpal pressure (15 cm H2O) and stored into deionized water; G4) SU applied with pulpal pressure (15 cm H2O) and stored into 75% ethanol. The specimens were restored with Filtek Z350 XT composite resin (3M ESPE). After 48 h in deionized water at 37ºC, the specimens were sectioned into dentin-resin beams with 1 mm2 of bonding area, which were submitted to the microtensile bond strength test after 1 day, 10 days or 30 days of storage in either deionized water or 75% ethanol. The variation of bond strength was determined by using 3-way ANOVA and Tukey's test (5% level of significance) analyses. All experimental variables - pulpal pressure (p=0.0007), storage media (p=0.0006) and time (p=0.0033) - had a statistically significant influence on the bond strength (p<0.05). The group restored without pulpal pressure and stored in water for 1 day showed the highest mean (35.26  4.63 A). This group was significantly different from groups restored with pulpal pressure and stored in water for 30 days (25.21  4.80 B) and ethanol for 10 days (24.63  3.18 B) and 30 days (23.31  6.25 B). Therefore, the .... / Mestre
170

Influência de uma substância antioxidante na união de materiais resinosos à dentina após a realização de clareamento /

Toseto, Roberta Mariano. January 2010 (has links)
Orientador: André Luiz Fraga Briso / Banca: Paulo Henrique dos Santos / Banca: Mirela Sanae Shinohara / Resumo: Este estudo analisou a influência do ascorbato de sódio 10% (AS) na formação de tags e camada híbrida em dentina após clareamento dental. Materiais e métodos: Foram testados 6 grupos. GI- Controle: somente restaurações de Resina Composta (RC); GII- Ascorbato de Sódio (AS) + RC; GIII- clareamento com peróxido de carbamida 10% (PC) + RC; GIV- PC + AS + RC; GV- clareamento com peróxido de hidrogênio 35% (PH) + RC; GVI- PH + AS + RC. Após os tratamentos, os dentes foram seccionados e descalcificados. Os cortes foram montados em lâminas de vidro e corados pelo método Brown & Brenn. A análise em microscopia óptica comum (Axiophot) em 400X, evidenciou os tags e camada híbrida formados. Resultados: Os dados foram tabulados, sendo obtidas as respectivas médias para comprimento dos tags e a espessura da camada híbrida: GI- 10 e 3.1μm, GII- 9.2 e 2.4 μm, GIII- 5.4 e 1.5 μm, GIV- 6.8 e 2.1 μm, GV- 5.7 e 1.6 μm, GVI- 7.1 e 2.1 μm. Conclusão: O clareamento dental com PC ou PH prejudica a formação de tags resinosos e camada híbrida. O uso do AS aumentou o comprimento destas estruturas / Abstract: This study analyzed the influence of 10% sodium ascorbate (SA) on tag and hybrid layer formation in dentin after bleaching. Materials and Methods: Six groups were tested: GI- Control: restoration; GII- Sodium Ascorbate (SA) + restoration; GIII- Bleaching with carbamide peroxide (CP) + restoration; GIV- bleaching with CP + SA+ restoration; GV- bleaching with 35% hydrogen peroxide (HP) + restoration; and GVI- HP + SA + restoration. After treatments, the teeth were sectioned and decalcified. The length of resin tags and thickness of the hybrid layer were analyzed using optical microscopy (Axiophot). Results: The following results were obtained for the groups: GI- 10 and 3.1 μm, GII- 9.2 and 2.4 μm, GIII- 5.4 and 1.5 μm, GIV- 6.8 and 2.1 μm, GV-5.7 and 1.6 μm, GVI-7.1 and 2.1 μm (length of resin tags and thickness of the hybrid layer, respectively). Conclusion: Dental bleaching with CP or HP impairs the formation of resin tags and hybrid layer. The use of SA increases these measures / Mestre

Page generated in 0.0534 seconds