• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 839
  • 37
  • 37
  • 37
  • 37
  • 36
  • 29
  • 9
  • 7
  • 6
  • 4
  • 3
  • 3
  • 1
  • 1
  • Tagged with
  • 899
  • 499
  • 251
  • 202
  • 193
  • 178
  • 152
  • 140
  • 140
  • 121
  • 114
  • 97
  • 97
  • 96
  • 94
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
191

Aplicação de lasers de microssegundos e femtossegundos para o condicionamento de tecidos duros dentais

SILVA, Patricia Fernandes Cassimiro da 17 January 2017 (has links)
Submitted by Pedro Barros (pedro.silvabarros@ufpe.br) on 2018-08-08T20:34:40Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) TESE Patricia Fernandes Cassimiro da Silva.pdf: 3402613 bytes, checksum: 7df862b6abd671c90962e79161be8239 (MD5) / Approved for entry into archive by Alice Araujo (alice.caraujo@ufpe.br) on 2018-08-16T22:48:54Z (GMT) No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) TESE Patricia Fernandes Cassimiro da Silva.pdf: 3402613 bytes, checksum: 7df862b6abd671c90962e79161be8239 (MD5) / Made available in DSpace on 2018-08-16T22:48:54Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) TESE Patricia Fernandes Cassimiro da Silva.pdf: 3402613 bytes, checksum: 7df862b6abd671c90962e79161be8239 (MD5) Previous issue date: 2017-01-17 / FACEPE / A utilização de diferentes LASERs na área odontológica tem se difundido rapidamente, sendo os LASERs de alta potência utilizados como uma alternativa para promover alterações morfológicas e químicas nas superfícies dentárias. O objetivo geral deste trabalho foi analisar o efeito da irradiação do substrato dental com dois LASERs de alta intensidade e com duração temporal diferentes (μs e fs), na resistência de união a compostos resinosos. Em um primeiro momento, avaliou-se diferentes parâmetros do LASER de Er,Cr:YSGG no esmalte, utilizando-se dois diferentes tipos de sistema adesivo (autocondicionante de dois passos e um adesivo universal), e seus efeitos na resistência de união através de testes de microcisalhamento. Os efeitos do LASER no esmalte foram avaliados através de microscopia eletrônica de varredura e a análise do padrão de fratura foi realizada com o auxílio da tomografia por coerência óptica. Não houve diferença significativa entre o grupo controle e o grupo tratado com 44 J/cm2. A análise pelo MEV revelou alterações morfológicas significativas da superfície do esmalte irradiado com laser, mostrando áreas de hidroxiapatita fundida e recristalizada nos grupos de 66 J/cm2. Concluiu-se que o uso do LASER com 44 J/cm² foi estatisticamente tão eficaz quanto o uso do ácido fosfórico e não pareceu influenciar a ação do adesivo autocondicionante. Em um segundo momento analisou-se o efeito da irradiação com LASER de femtossegundo Ti:Safira na dentina sadia e erodida, através de microscopia eletrônica de varredura, microscopia de força atômica e tomografia por coerência óptica, bem como seus efeitos na resistência de união através de testes de microcisalhamento utilizando-se um adesivo autocondicionante de dois passos. A resistência de união máxima foi registrada pelo grupo SD240 (16,42 MPa) e a resistência de união mínima foi registrada pelo grupo ED (8,89 MPa). O teste de Mann Whitney demonstrou diferenças entre ED e todos os outros grupos. Pode-se concluir que o LASER de femtossegundo Ti:Safira foi capaz de ablacionar o tecido dentinário sadio, proporcionando a abertura dos túbulos dentinários e uma certa rugosidade superficial. Entretanto não houve melhora significativa na adesão. A irradiação com LASER de femtossegundo promoveu maior ablação nas amostras de dentina erodida e melhora na adesão de forma significativa. / The use of different lasers in dentistry has been diffused rapidly, with high power lasers being used as an alternative to promote chemical/morphological changes on the tooth surface. The main objective of this work was to analyze the effect of dental substrate irradiation with two high intensity lasers with different temporal duration (μs and fs) on bond strength to resinous compounds. At first, different parameters of the Er,Cr:YSGG laser were evaluated in enamel using two different types of adhesive system (two-step self-etching and universal adhesive), and their effects on bond strength through micro-shear tests. The laser effects on the enamel were evaluated by scanning electron microscopy and the analysis of the fracture pattern was performed with the aid of optical coherence tomography. There was no statistically significant difference between the control group and the treated group with 44J/cm2. SEM analysis revealed significant morphological alterations of the laser-irradiated enamel surface, showing areas of melted and recrystalized hydroxyapatite in the 66 J/cm² groups. It was concluded that the laser use with 44J/cm2 was statistically as effective as the use of phosphoric acid and did not appear to influence the action of the self-etching adhesive. In a second moment, the effect of femtosecond laser irradiation with the Ti:Sa laser was analyzed in sound and eroded dentin, by scanning electron microscopy, atomic force microscopy and optical coherence tomography, as well as their effects on bond strength through micro-shear tests using a two-step self-etching adhesive. The maximum bond strength was recorded for the SD240 (16.42 MPa) and the minimum bond strength was recorded for the ED (8.89 MPa). The Mann Whitney test demonstrated differences between ED and all the other groups. It can be concluded that the femtosecond Ti:Sa laser was able to ablate the sound dentin tissue, providing the opening of the dentinal tubules and a certain superficial roughness. However, there was no significant improvement in adhesion. Femtosecond laser irradiation promoted greater ablation in the eroded dentin samples and improved adhesion significantly.
192

Avaliação da resistencia de união de sistemas adesivos de dupla-presa, fotoativados e autopolimerizavel indicados para cimentação de peças proteticas / Bond strength evaluation of light, self and dual-cured adhesive systems for indirect composite restorations

Menezes, Maria Jose Lorena de 25 October 2005 (has links)
Orientador: Marcelo Giannini / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-05T09:28:29Z (GMT). No. of bitstreams: 1 Menezes_MariaJoseLorenade_M.pdf: 1249482 bytes, checksum: 6b6887d83579b7e88d17d5237808ac6a (MD5) Previous issue date: 2005 / Resumo: O propósito deste estudo in vitro foi avaliar a influência de diferentes sistemas de cimentação que utilizam adesivos dentinários fotoativáveis, de duplapresa e autopolimerizável na resistência à tração (TR) de restaurações indiretas em compósito no substrato dentinário. Trinta e seis terceiros molares extraídos e com tecido dentinário sadio foram seccionados perpendicularmente ao seu longo eixo, na região do terço oclusal da porção coronária com um disco diamantado dupla face e abrasionados com lixa de carboneto de silício (SiC) de granulações 400 e 600, expondo uma superfície dentinária plana de profundidade média sem remanescente de esmalte, observado através do critério visual. Os dentes foram divididos aleatoriamente em seis grupos experimentais de acordo com os sistemas de cimentação (n=6): Grupo 1 - Single Bond/3M-ESPE (SB) e Grupo 2 Scotchbond Multipurpose Plus/3M-ESPE (SBMP), em associação com o cimento resinoso Rely X/3M-ESPE (RX); Grupo 3 - Prime & Bond NT/Dentsply (PB), e Grupo 4 - Prime Bond NT + Self-Cure Activator/Dentsply (PBA), associado ao cimento resinoso Enforce/Dentsply (EN); Grupo 5 - Clearfil SE Bond/Kuraray (CSB) e Grupo 6 - ED Primer/Kuraray (ED), em associação com o cimento resinoso Panavia F/Kuraray (PF). Após a aplicação dos sistemas adesivos de acordo com as recomendações dos fabricantes, foram fixados discos de compósito Clearfil APX (Kuraray) com aproximadamente 2 mm de espessura, com os respectivos cimentos resinosos. Os grupos tiveram os adesivos fotoativados previamente (1, 3, 5) e após a cimentação por 40 segundos. Nos grupos 2, 4 e 6 foram utilizados os adesivos duais e o autopolimerizável sem fotoativação inicial e todo sistema fotoativado por 40 segundos apenas após a fixação. Foram realizadas secções paralelas ao longo eixo das amostras nos sentidos vestíbulolingual (VL) e mésio-distal (MD), originando espécimes em forma de paralelepípedo com área de secção transversal de aproximadamente 0,8 mm2. Quatro espécimes, de cada amostra foram testados em um dispositivo para microtração acoplado em Máquina Universal de Ensaio (4411 Instron), com velocidade de 0,5 mm/min. Os resultados obtidos foram expressos em MPa e submetidos à Análise de Variância e ao Teste de Tukey (5%). Os valores médios de TR (MPa) foram os seguintes: Grupo 1 (SB/RX) = 26,74 ± 7,44 ab; Grupo 2 (SBMP/RX) = 32,89 ± 6,16 a; Grupo 3 (PB/EN) = 26,11 ± 4,48 ab; Grupo 4 (PBA/EN) = 25,30 ± 6,42 ab; Grupo 5 (CSB/PF) = 16,82 ± 5,52 bc e Grupo 6 (ED/PF), = 11,20 ± 6,79 c. O grupo 2 (SBMP/RX) apresentou maior TR que os grupos 5 e 6, os quais utilizaram adesivos autocondicionantes. Na comparação entre sistemas adesivos de mesmo fabricante e com o mesmo agente de fixação resinoso, não houve diferença significativa entre eles, exceto para os materiais do fabricante Dentsply / Abstract: The purpose of this study in vitro was to evaluate the tensile bond strength (µTBS) of light-, self- and dual-cured dentin adhesive systems using foundation of composite blocks with resinous agents. Thirty-six third molars caries-free were extracted and sectioned perpendicully to the long axis, in the third occlusal area of the coronary portion with a diamond disk of high concentration and scorched with 400 and 600 grit SiC, exposing a surface dentinária plane of medium depth without enamel remainder, observed through the visual criteria. The teeth were randomly divided into six experimental groups accorded with the foundation systems (n=6): Group 1-Single Bond/3M-ESPE (SB) and Group 2-Scotchbond Multipurpose Plus/3M-ESPE (SBMP), in association with the resinous cement Rely X/3M-ESPE (RX); Group 3-Prime & Bond NT/Dentsply (PB), and Group 4 Prime & Bond NT + Self-cure Activator/Dentsply (PBA), associated the resinous cement Enforce/Dentsply (EN); Group 5-Clearfil SE Bond/Kuraray (CSB) and Group 6 ED Primer/Kuraray (ED), in association with the resinous cement Panavia F/Kuraray (PF). After the application of the systems according with the manufacturer's instruction, composite blocks Clearfil APX (Kuraray) were fastened with approximately 2 mm thick, with the resinous cement respective. The groups 1, 3 and 5 had the adhesive light-cured previously and after the foundation for 40 seconds. In the groups 2,4 and 6 were used the dual adhesive without initial lightactivated and all light-cured system for 40 seconds, only after the foundation. The samples were vertically, buccal-lingual (VL) and mesiodistal (MD) sectioned, resulting specimens in form of toothpicks with a cross-sectional area of approximately 0,8 mm2. Four specimens from each sample were tested in a microtensile device coupled in an universal testing machine (4411 Instron), at a crosshead speed of 0.5 mm/min. The results were expressed in MPa and statistically analysed by analysis of variance (only facto r) and Tukey test (5%). The medium values of µTBS (MPa) were the following: Group 1 (SB/RX) = 26.74 ± 7.44 ab; Group 2 (SBMP/RX) = 32.89 ± 6.16 a; Group 3 (PB/EN) = 26.11 ± 4.48 ab; Group 4 (PBA/EN) = 25.30 ± 6.42 ab; Group 5 (CSB/PF) = 16.82 ± 5.52 bc and Group 6 (ED/PF), = 11.20 ± 6.79 c. In the medium values of TR the G4 had lower rank than the other groups, excepted to the observed in the G6. The group 2 (SBMP/RX) showed larger µTBS than the groups 5 and 6, which used self-etching adhesive. In comparison among adhesive systems from the same manufacturer and with the same resin cement, there was not significant difference among them, except for the products of Dentsply Company / Mestrado / Dentística / Mestre em Clínica Odontológica
193

Influencia de tratamentos superficiais do substrato dentinario na resistencia a tração de sistemas adesivos

Chaves, Patricia 03 February 2001 (has links)
Orientador : Marcelo Giannini / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T03:36:04Z (GMT). No. of bitstreams: 1 Chaves_Patricia_M.pdf: 3011134 bytes, checksum: 6da628a4429da7224232b60947f51674 (MD5) Previous issue date: 2001 / Resumo: O propósito deste estudo in vitro foi avaliar a influência de diferentes tratamentos superficiais dentinários: aplicação direta sobre a smear layer (SL), condicionamento com ácido fosfórico 37% por 15 segundos (AF), jateamento com óxido de alumínio (Ah03) 50llm por 10 segundos (lA) e condicionamento com ácido etileno diamino tetra-acético (EDT A) 0,5 M pH 7,0 por 2 minutos (ED) na resistência à tração (RT) de três diferentes sistemas adesivos: Prime & Bond NT/Dentsply (PB), Clearfil Mega Bond/Kuraray Co. (CMB) e Etch & Prime 3.0/Degussa (EP). Trinta e seis terceiros molares foram seccionados na altura da metade da coroa clínica no sentido transversal, perpendicularmente ao seu longo eixo, com um disco diamantado de alta concentração e abrasionados com lixa de carbureto de silício (SiC) de granulação 600. Os dentes foram divididos aleatoriamente em doze grupos de acordo com o tratamento superficial e o sistema adesivo utilizado. Blocos de compósito (TPH Spectrum/Dentsply) com altura de 10 mm foram incrementalmente confeccionados nessas superficies e, após 24 horas de armazenamento em solução salina a 37:1: 1 oCo secções foram realizadas paralelamente ao longo eixo das amostras nos sentidos mésio-distal (MD) e vestíbulo-lingual (VL). De cada amostra foram retirados quatro espécimes (n= 12), testados através de um dispositivo específico para microtração (Bencor - Multi-T. Danville Engineering Co, Danville) com velocidade de 0,5 mm/min. O efeito superficial produzido pelas diferentes técnicas e a interface de união foram observados em microscopia eletrônica de varredura (MEV) com magnificações de 2000X e 1000X, respectivamente. Os valores médios de RT em Mega Pascal (MPa) foram: PB/SL= 40,17:t6,14, PB/AF= 38,42:t9,30, PB/JA= 38,58:t12,26 e PB/ED= 44,55:t2,98; CMB/SL= 21,13:t4,27, CM/AF= 32,89:t1O,13, CM/JA= 25,74:t4,O9, CM/ED= 28,37:t7,83; EP/SL= 12,8:t4,21, EP/AF= 17,O4:t2,99, EP/JA= 11,38:t3,60 e EP/ED= 17,72:tO,84. Os dados foram estatisticamente analisados pela análise de variância (ANOV A) e teste Tukey. Diferenças estatísticas significativas foram observadas quanto ao tipo de adesivo utilizado (p<O,O5), enquanto diferenças estatísticas significativas quanto ao tipo de tratamento da smear layer, para o mesmo sistema adesivo, não foram observadas (p>O,O5) / Abstract: The purpose of this in vitro study was to investigate the effects of different smear layer treatments: direct application over smear layer (SL), etching with 37% phosphoric acid for 15 seconds (P A), sandblasting with 50Jlm oxide aluminum for 10 seconds (OA) and etching with 0.5 M EDTA pH 7.0 for 2 minutes (ED) on bond strength (BS) of three adhesive systems: Prime & Bond NT/Dentsply (PB), Clearfil Mega Bond/Kuraray Co. (CMB) and Etch & Prime 3.0/Degussa (EP). Thirty-six third molars were sectioned on middle crown with a high concentrated diamond disc and abraded with a SiC 600 grid paper. Teeth were divided randomly into twelve groups according to treatment and adhesives used. Resin "crowns" with 10.0 mm high were constructed incrementally with TPH Spectrum/Dentsply composite and storaged in distilled water at 37:1:1 °C for 24 hours. Bonded specimens were serially sectioned in both "x" and "y" directions transversally to the bonded interface to obtain four repetitions of bonded sticks, per tooth (n=12). Each bonded stick was tested under tension in a Bencor Multi-T testing assembly (Danville Engineering Co, Danville) at 0.5 mm/min. Superficial effects produced by different techniques and the bonded interface were observed on scanning electron microscope (SEM) on 2000X and 1000X magnifications, respectively. Mean bond strength of specimens tested (MPa) were: PB/SL= 40.17:1:6.14, PBIPA= 38.42:1:9.30, PB/OA= 38.58:1:12.26 and PBIED= 44.55:1:2.98; CMB/SL= 21.13:1:4.27, CM/PA= 32.89:1:10.13, CM/OA= 25.74:1:4.09, CMIED= 28.37:1:7.83; EP/SL= 12.8:1:4.21, EPIPA= 17.04:1:2.99, EP/OA= 11.38:1:3.60 and EPIED= 17.72:1:0.84. Data were statistically evaluated by ANOV A and Tukey testo Statistically significant differences were observed among adhesives (p<O.O5) while no significative differences were found among smear layer treatments with the same dentin adhesive (p>O.O5) / Mestrado / Dentística / Mestre em Clínica Odontológica
194

Avaliação do desempenho clinico de restaurações em resina composta e aspectos morfologicos da interface dentina/resina em dentes deciduos

Puppin-Rontani, Regina Maria, 1959- 29 July 2018 (has links)
Tese (livre-docencia) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-29T04:27:17Z (GMT). No. of bitstreams: 1 Puppin-Rontani_ReginaMaria_LD.pdf: 2566951 bytes, checksum: 0b33eff6232db58b252aea0f5449e540 (MD5) Previous issue date: 1999 / Resumo: O objetivo deste estudo foi avaliar o desempenho clínico de restaurações em resina composta realizadas em dentes decíduos após 18 meses. Foram selecionados 41 molares decíduos de crianças de 4 a 9 anos de idade da Clínica de Odontologia Infantil da FOP/UN1CAMP, que foram restaurados com o sistema adesivo Scotchbond Multipurpose Plus e resina composta Z100. As restaurações foram avaliadas no inicio do estudo, e aos 6, 12 e 18 meses seguintes, empregando o critério de Cvar e Ryge, (1971), para a análise clinica direta e para a análise indireta, modelos em gesso obtidos nos mesmos períodos. As restaurações foram também avaliadas radiograficamente nos mesmos períodos. Para a análise morfológica da interface dentina/resina foram usados 7 dentes esfoliados que foram seccionados longitudinalmente no sentido mésio/distal e observados em microscopia eletrônica de varredura Os resultados mostraram que 100% (n= 40) das restaurações avaliadas aos 6 meses receberam escore A (Alpha) para forma anatômica, cor, alteração de cor e degradação marginal e cáries secundárias. Aos 12 meses, 96,4% (n= 28) das restaurações receberam escore A e 3,4% C (Charlie) para os mesmos critérios avaliados. Aos 18 meses foram avaliadas 27 restaurações, sendo que todas receberam escore A para os mesmos critérios. Foram avaliadas indiretamente 23 restaurações aos 6, 12 e 18 meses após o inicio do experimento Não foi observado desgastes ou fraturas nas restaurações. Na avaliação da interface restauração/dentina, observou-se a formação de camada híbrida consistente e adaptada à estrutura da dentina. Conclui-se que os materiais investigados Scotchbond Multipurpose Plus e Z100 pela técnica do condicionamento ácido total apesar do excelente desempenho clinico/radiográfico observado com relação à forma anatômica, cor, alteração de cor e degradação marginais e cáries secundárias, devem ser empregados com critério em dentes decíduos devido a alta resistência ao desgaste apresentada pelo compósito Z100 / Abstract: The aim of this study was to evaluate the composite resin restorations' performance in primary teeth using total etching technique, after 18 months. Forty-one primary teeth were restored with Scotchbond Muhi-Purpose Plus and Z100 composite resin. The restorations were evaluated at the baseline at 6, 12 and 18 months using the Cvar and Ryge criteria and indirect analyses using stone casts observed at the stereoscopic microscopy. Seven esfoliated teeth from the sample were observed at scanning electron microscopy in order to verify the morphology of the dentin/adhesive interface. The results showed that 100% of the restorations evaluated at 6 months after placement (n=40) were rated as A (Alpha) to anatomic form, color match, marginal discoloration, marginal degradation, and secondary caries. At 12 months 96.4% of the restorations (n=27) were rated as A and 3 6% as C (Charlie) for the same evaluation criteria. At 18 months 100% of the restorations (n=27) were rated as A for the same evaluation criteria. Twenty-three restorations were evaluated at the indirect analyses at 6, 12 and 18 months after placement. No wear was found on the restorations. The enamel wearing could be observed at the restoration margins The SEM samples showed the hybrid layer formation with 3.73 um thickness, resin tags and no spaces between the primary dentin and adhesive. It was concluded that, in spite of the good performance in relation to the anatomic form, color match, marginal discoloration, marginal degradation and secondary caries, the composite investigated should be used carefully at primary teeth due to its hardness. Future researches should be conducted to verify the influence of the hardness of this material in the occlusion features / Tese (livre-docencia) - Univer / Odontopediatria / Livre-Docente em Odontologia
195

Determinação do numero de dentes, palitos e influencia da localização dos palitos na dentina para o ensaio de microtração / Determination of sample size, plot size and beams location on the dentin surface for microtensile test method

Arias, Vanessa Gallego 16 February 2007 (has links)
Orientadores: Luiz Andre Freire Pimenta, Glaucia Bovi Ambrosano / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-08T12:07:02Z (GMT). No. of bitstreams: 1 Arias_VanessaGallego_D.pdf: 611326 bytes, checksum: ec27b51bc2f986d28374469ca93f8730 (MD5) Previous issue date: 2007 / Resumo: Os objetivos deste trabalho foram determinar o número ótimo de dentes (tamanho da amostra), número de palitos (tamanho da parcela) e a influência da localização dos palitos na dentina para o ensaio de Microtração. Foram utilizados 80 dentes bovinos, os quais apresentaram as superfícies vestibulares coronárias desgastadas, para a exposição dentinária. Os dentes foram divididos, aleatoriamente, em dois grupos (n=40). Os sistemas adesivos utilizados foram o Single Bond (SB- G1) e Tyrian SPE /One Step Plus (TY- G2). Os dentes foram restaurados com resina composta Filtek Z-250, formando um bloco com dimensões de 4 mm de largura, 6 mm de comprimento e 4 mm de altura, sendo posteriormente seccionados em cortadeira metalográfica, obtendo-se palitos com aproximadamente 0.8 mm2 de área de interface adesiva (dente/resina), totalizando 12 palitos por dente. Os palitos foram fixados a uma máquina Universal de Ensaio para a obtenção dos valores de união, em MPa, com velocidade de avanço de 0,5mm/min. A partir do delineamento inteiramente ao acaso, com 40 repetições por sistema adesivo e 12 palitos por dente, a análise de variância foi realizada e os cálculos das respectivas médias e desvios-padrão. Para a determinação do número de repetições (dentes), o poder do teste foi calculado em função do número de dentes. Adicionalmente, diferentes tabelas foram obtidas através da simulação da variação entre as médias dos grupos, adotando-se 5, 10, 15, 20, 25, 30, 35 e 40% de variação inter-grupos. Também foi estipulado o Coeficiente de Variação do experimento, ou variação intra-grupos, em 10, 20 e 30% e o mesmo procedimento, citado acima, foi realizado. Para a determinação do número de palitos por dente (tamanho da parcela), 12 diferentes simulações (tamanhos) foram criados a partir dos valores originais, através da exclusão aleatória de 1 palito a cada vez que a ANOVA foi realizada até a permanência de apenas 1 palito por dente. O ponto de máxima curvatura modificado, proposto por Méier & Lessman (1971) foi calculado. Adicionalmente, a mesma metodologia foi aplicada, utilizando-se 20 e 10 dentes por grupo. Já para a análise da região dentinária foi aplicada a Análise de Variância em parcela subdividida e teste de Tukey, para a verificação das possíveis diferenças regionais e suas interações. Os resultados demonstraram que a utilização de 6 dentes por grupo presentou um poder de 88%. Entretanto, este número pode variar em função do CV e da diferença entre as médias dos grupos. Já para o tamanho ideal de parcela obtido foi de 7 palitos por dente, independente do número de unidades experimentais. Com relação à localização dos palitos na dentina, os resultados demonstraram diferença estatística entre os palitos nas diferentes linhas (p=0,005) e entre as colunas (p=0,00001). Também houve a interação entre sistema adesivo e linha (p=0,019). O teste de Tukey demonstrou que tanto para o sistema adesivo SB quanto para o TY os melhores resultados foram encontrados nos palitos centrais. Concluiu-se o número mínimo de dentes foi de 6 com 7 palitos por dente, utilizando os palitos centrais da área de união / Abstract: The objectives of this study were to determine the ideal number of teeth (sample size), number of beams per tooth (plot size) and the influence of the beams location on the dentin surface for microtensile testing-MT. Eighty bovine teeth were selected and the dentin was flat exposed. The teeth were randomly divided in two groups (n=40), using the adhesive systems: Single Bond (SB- G1) and Tyrian/One Step Plus (TY- G2). A â?¿crownâ?? was done with composite resin Filtek Z-250, presenting 4 mm width, 6 mm length and 4 mm high. The specimens were sectioned, at a metalographic machine, in 12 beams with 0,8mm2 area interface (dentin/resin). The beams were attached in a Universal Machine and the MT was performed (0.5mm/min) and the bond strength values expressed in MPa. Using the study design random model, with 40 repetitions per group and 12 beams per tooth, the one-way ANOVA was applied and the means and standard deviation were obtained. To determine the optimal sample size, the powerâ?¿s test was calculated. Additional values were simulated decreasing the difference between the groups means, using 5, 10, 15, 20, 25, 30, 35 and 40% (inter-tooth variability). Different CV were used (10, 20 and 30%) and the same procedures describes above were performed. For the analysis of the plot size, 12 different experimental unit sizes were created from the original values by excluding randomly 1 beam every time when one-way ANOVA was performed until only 1 beam per tooth was left, using 40, 20 and 10 teeth per group (EU). The experimental coefficients of variation (CVexp) were calculated and a regression function was estimated. The maximum curvature point was calculated from the formula proposed by Meier & Lessman (1971). For the dentin region, the Split pot analysis and Tukeyâ?¿s test were applied to analyze the regional influence and the possible interactions. The results demonstrated that using 6 teeth, the power arranged 88%. But this number may variety depending CV and the means between groups. The optimal plot size was obtained with 7 beams per tooth independently of the EU. The regional analysis demonstrated statistical significant differences between rows (p=0.005) and columns (p=0.00001). The interaction between adhesive system and rows was statistical significant (p=0.019). The Tukeyâ?¿s test demonstrated that highest bond strength values were to the central beams for both adhesive systems. The conclusion of the study was the optimal sample size was 6 teeth per group, presenting 7 beams per tooth, using the central beams / Doutorado / Dentística / Doutor em Clínica Odontológica
196

Analise por microscopia de polarização e microscopia eletronica de varredura da estrutura dentinaria de dentes bovinos frente a diferentes substancias quimicas auxiliares de uso endodontico / Polarization and scanning electron microscopy of bovine dentine structure after using different endodontic auxiliary chemical substances

Moreira, Danna Mota 16 February 2007 (has links)
Orientador: Alexandre Augusto Zaia / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-08T12:23:42Z (GMT). No. of bitstreams: 1 Moreira_DannaMota_M.pdf: 5878321 bytes, checksum: 4089eb0ec4e19d31fd9966e0b4a6b16f (MD5) Previous issue date: 2007 / Resumo: O objetivo desse trabalho foi avaliar a ocorrência de alterações na estrutura e organização do colágeno presente na matriz orgânica da parede dentinária do canal radicular de incisivos bovinos bem como, avaliar a topografia da matriz inorgânica desta estrutura após irrigação com hipoclorito de sódio 5,25%, EDTA 17% e clorexidina gel 2%. Foram utilizados 60 dentes bovinos divididos aleatoriamente em seis grupos com 10 dentes cada: G1 - Hipoclorito de sódio (NaOCl) 5,25% e EDTA 17%; G2 - Clorexidina gel 2%; G3 - NaOCl 5,25%; G4 - EDTA 17%; G5 - Clorexidina gel 2% e EDTA 17%; G6 - Solução de cloreto de sódio 0,9% (Controle). Uma análise paralela foi realizada em 10 dentes onde nenhum tipo de procedimento foi realizado, sendo possível a obtenção dos parâmetros da birrefringência característica de incisivos bovinos sem instrumentação. As amostras experimentais foram submetidas à instrumentação e irrigação com as diferentes substâncias químicas auxiliares e em seguida, segmentadas em dois fragmentos. Um fragmento foi processado histologicamente utilizando o corante pricrosirius e em seguida, seu retardo óptico foi mensurado por meio de microscopia de polarização. O outro segmento foi preparado e avaliado por meio de microscopia eletrônica de varredura. Os resultados das mensurações dos retardos ópticos foram submetidos à análise estatística por meio do teste de Dunnet. Os resultados demonstraram que os grupos tratados com a clorexidina gel 2% e EDTA 17%, associados ou não, não obtiveram diferença estatisticamente significante em relação ao grupo controle. Nos grupos tratados com NaOCl 5,25%, associado ou não ao EDTA 17%, as médias dos retardos ópticos foram estatisticamente diferentes ao grupo controle. Concluindo que o NaOCl 5,25% provoca alterações na organização macromolecular do colágeno presente na matriz orgânica da dentina radicular de dentes bovinos. A análise realizada por meio da MEV demonstrou alterações estruturais na matriz inorgânica em todos os grupos em que o EDTA 17% foi utilizado / Abstract: The aim of this study was to evaluate the change in collagen structure and organization present in the organic matrix of the dentine wall of the root canals of bovine inferior incisors as well as the topography of the inorganic matrix after irrigation with 5.25% sodium hypochlorite, 17% EDTA and 2% chlorexidine gel. Sixty bovine incisors were randomly divided into six groups of 10: G1 - 5.25% Sodium Hypochlorite (NaOCl) and 17% EDTA; G2 - 2% Chlorexidine gel; G3 - 5.25% NaOCl; G4 - 17% EDTA; G5 - 2% Chlorexidine gel and 17% EDTA; G6 (Control) - 0.9% Sodium chloride. A parallel analysis was performed with 10 teeth which had not been submitted to any treatment. Hence, it was possible to obtain parameters for the birefringence characteristic of non-instrumented inferior bovine incisors. Experimental samples were submitted to instrumentation and irrigation with different auxiliary chemical substances and then segmented in two. One fragment was histologically processed using picrosirius pigment. Its optical retardations were measured through polarization microscopy. The second fragment was prepared to be evaluated through scanning electron microscopy. The optic retardation measurement data were submitted to statistical analysis using Dunnet?s test. Results revealed that the groups that associated or not 2% chlorexidine gel and 17% EDTA were not statistically different in relation to the control group. For the groups which 5.25% NaOCl was used, associated or not to 17% EDTA, the average optic retardations were statistically different to the control group. Therefore, 5.25% sodium hypochlorite proved to cause alterations to the molecular organization of collagen present in the organic matrix of root dentine of bovine teeth. Scanning electron microscopy showed structural alterations of the inorganic matrix of all groups tested with 17% EDTA / Mestrado / Endodontia / Mestre em Clínica Odontológica
197

Avaliação da adaptação à dentina de vários agentes de proteção com ou sem sistemarestaurador adesivo, em função de diferentes tratamentos da superfície dentinária. / Evaluation of the marginal finishing of cavity preparations in relation to different instrumentation methods.

Margareth da Silva Coutinho 05 April 2000 (has links)
Este estudo quantificou micrometricamente o índice de adaptação à dentina (presença ou ausência de fenda interfacial) de vários agentes protetores à base de hidróxido de cálcio de ativação química - Dycal e de luz visível - Prisma VLC Dycal e Ultra-Blend® plus e cimento de ionômero de vidro convencional - Ketac Bond e fotoativado - Vitrebond; associados a diferentes tratamentos de superfície dentinária, com e sem a presença de sistema restaurador adesivo (Primer & Bond 2.1 + TPH Spectrum). Os tratamentos dentinários foram jatos de ar/água, condicionamento com ácido poliacrílico a 25% por 10s e ácido fosfórico a 37% por 15s. Foram utilizados 200 dentes, os quais numa metade foi desgastado o esmalte e os preparos realizados em dentina e na outra metade repetiu-se o preparo cavitário envolvendo esmalte e dentina. Cavidades tipo classe V foram realizadas com 3mm de diâmetro e 0,8mm de profundidade em dentina e 0,8mm quando envolvido o esmalte. Após o preenchimento da cavidade, os corpos-de-prova foram incluídos em resina epóxica e seccionados longitudinalmente no sentido vestíbulo-lingual. Foram obtidas réplicas em negativo utilizando-se material de moldagem à base de polivinil siloxana (Aquasil), para a avaliação da desadaptação à dentina, por meio de microscópia de luz refletida em campo escuro. Os dados obtidos microscopicamente foram submetidos aos Testes de Kruskal-Wallis e as comparações múltiplas pelo Teste de Dunn. Os resultados demonstraram que quando comparados o comprimento e a largura da desadaptação à dentina dos agentes protetores, entre as condições experimentais com e sem a presença do sistema restaurador adesivo, o cimento de ionômero de vidro fotopolimerizável Vitrebond obteve os melhores resultados, sobrepujando, inclusive, o Ketac Bond ativado quimicamente. Numa posição intermediária vêm o Ultra-Blend® plus e o cimento de hidróxido de cálcio auto-ativado Dycal e, por último, o cimento de hidróxido de cálcio fotopolimerizável Prisma VLC Dycal, que apresentou a maior desadaptação. / The present study evaluated the length and width of interface gaps between dentin and the following lining materials: chemically cured Dycal Advanced Formula II and light cured Prisma VLC Dycal and Ultra-Blend® plus calcium hydroxide bases; chemically cured Ketac Bond and light cured Vitrebond glass ionomer cements. Dentin cavities prepared in human teeth were pre-treated with only an air/water Spray or with a 25% Polyacrylic acid solution for 10s, or a 37% Phosphoric acid solution for 15s. One half of cavities were prepared in dentin (3mm wide, 0.8mm deep) and have been filled with only the linning materials. The other half of the cavities were enamel dentin cavities had a 0.8mm with enamel layer, 3mm wide, 0.8mm deep below the dentinoenamel junction. Theses cavities received a layer of lining material have then been treated with an adhesive system an restored with a composite resin. In order to access the dentinal interfacial adaptation, the specimens were sectioned longitudinally in buccal to lingual direction thorough the center of the restorations. Low viscosity polyvinyl siloxane impression material (Aquasil) was used to obtain negative replicas. The replicas were examined with a Zeiss Photomicroscope and the length and width of the gaps were measured. The values were submitted to Kruskall Wallis Test and Multiple Comparation Dunn Test. Results demonstrated that, on the experimental conditions used, the glass ionomer cements obtained the best results, specially the Vitrebond. The Ultra-Blend plus and Dycal, showed an intermediary position. Prisma VLC Dycal showed the powerest adaptation.
198

Mapeamento da variação regional da resistência adesiva em superfícies planas de dentina.

Raquel Sano Suga Terada 22 February 2001 (has links)
O presente trabalho avaliou a influência das variações morfológicas do substrato dentinário na resistência de união à microtração de três sistemas adesivos resinosos: Clearfil Liner Bond 2V, One-Step e Single Bond, empregando como substrato superfícies planas de dentina. Para o preparo e exposição da superfície de dentina, o esmalte oclusal foi desgastado com lixas de carbureto de silício de granulação 320 e 600. Doze dentes foram tratados com um dos sistemas adesivos e foi aplicada uma camada de 1 centímetro de altura em resina composta Z100, pela técnica incremental. Após armazenagem em água destilada em estufa a 37ºC por 24 horas, os espécimes foram preparados para serem submetidos ao teste de microtração. Utilizando-se uma máquina de cortes seriados, os dentes foram fatiados em espessuras de aproximadamente 0,8 mm nos sentidos mésiodistal e vestíbulo-lingual, obtendo-se médias de áreas de adesão de 0,7 mm2. Foram obtidos, em média, 23 espécimes por dente. Identificando-se cada espécime através de um código de cores, a superfície de cada dente foi mapeada. Para a leitura da resistência de união, cada espécime em forma de “palito” foi afixado individualmente em um dispositivo de microtração, Bencor Multi-T, de modo a posicionar a área de adesão perpendicularmente ao longo eixo do espécime. Após o teste, o modo de fratura da interface adesiva foi avaliado. Os resultados obtidos permitiram concluir que existe uma variação regional da resistência de união em superfícies planas de dentina. Independentemente do sistema adesivo empregado, a variação da resistência de união encontrada em superfícies planas de dentina foi determinada por variações no substrato dentinário.Comparando-se a resistência de união entre os materiais, os sistemas One-Step (53,97 ± 12,58 MPa) e Single Bond (52,59 ± 17,67 MPa) apresentaram uma resistência semelhante e estatisticamente superior ao sistema Clearfil Liner Bond 2V (32,90 ± 12,43 MPa). Comparando-se a resistência de união à dentina central e à dentina periférica, os três materiais não apresentaram uma diferença estatisticamente significante. / The present work evaluated the influence of morphological variations of the dentinal substrate in the microtensile adhesive strength of three adhesive systems: Clearfil Liner Bond 2V, One-Step and Single Bond, using flat dentin surfaces. For the preparation and exposure of the dentin surface, the occlusal enamel was ground with 320 and 600 – grit SiC paper. The teeth were treated with one of the adhesive systems and a 1cm thick layer of Z100 resin composite was built up on the surface. After storage in distilled water at 37ºC for 24 hours, the specimens were prepared to be subjected to the microtensile test. With the aid of a micrometer the teeth were serially sectioned in both “x” and “y” directions to result in several bonded sticks of approximately 0.7 mm2 of cross-sectional area. Approximately twenty-three specimens per tooth were obtained. Each specimen was identified by a color code and the flat dentin surface was mapped. For the reading of the adhesive strength, each bonded stick was individually gluded to a Bencor Multi-T microtensile device with the adhesive area perpendicularly oriented to the long axis of the device. After testing, the mode of fracture of the adhesive interface was evaluated. The conclusions of this study were: there is a regional variance in the adhesive strenght on a flat dentin surface; regardless of the adhesive system used, the variation of the adhesive strength found on flat dentin surfaces was determined by variations in the dentinal substrate; when comparing the adhesive strength among the materials, One-Step (53,97 MPa ± 12,58) and Single Bond (52,59 MPa ± 17,67) systems presented a adhesive strength similar and statistically higher than the Clearfi Liner Bond 2V (32,90 MPa ± 12,43) system; when comparing the adhesive strength to both central and peripheral dentin, the three materials did not present any statistically significant differences.
199

Estudo sobre o papel dos solventes na produção de união à dentina / The role of solvents on bonding to dentin

Fernanda Cristina Pimentel Garcia 07 April 2005 (has links)
O presente estudo teve por objetivo avaliar o efeito das interações moleculares entre solventes e monômeros com a matriz de dentina desmineralizada, nas alterações das propriedades mecânicas, na taxa de evaporação e na resistência de união (RU). As propriedades mecânicas da dentina desmineralizada foram determinadas através da análise do módulo de elasticidade máximo aparente (EMax) e do relaxamento das tensões (RT). Os resultados permitiram concluir que o Emax foi dependente do tipo de solvente utilizado e do tempo. A taxa de enrijecimento da matriz desmineralizada foi maior para acetona e etanol, intermediária para o ar, metanol e propanol, menor para o HEMA e praticamente nenhuma para água. Da mesma forma, o RT dependeu da solução em que os espécimes foram equilibrados, previamente ao ensaio mecânico, e do tipo de deformação induzida ao espécime. De uma maneira geral, a resposta da matriz desmineralizada (RT) foi maior quando equilibrada em acetona, propanol e etanol, intermediária para HEMA, butanol e metanol e menor para água. A tensão máxima gerada com o tempo foi maior quanto maior a deformação inicial induzida (3-5-10%). A taxa de evaporação e a perda de massa total (%) de misturas experimentais à base de 35%HEMA/65%solventes foram determinadas através da medida de perda de massa em função do tempo, a partir de duas superfícies distintas (cubos de dentina desmineralizados x superfície livre). A taxa de evaporação e a perda de massa foi maior para HEMA/acetona (H/AC) e HEMA/metanol (H/M), intermediária para HEMA/etanol (H/E) e menor para HEMA/água (H/A), sendo esses valores superiores a partir dos cubos de dentina. A RU foi determinada pelo emprego do teste de microtração. Para verificar a influência do aspecto de brilho superficial, foram aplicadas 2 ou 3 camadas de misturas experimentais (35%HEMA/65%solventes) sobre a dentina previamente condicionada. Os maiores valores de RU foram obtidos com a manutenção do brilho superficial para todas as soluções testadas (ou seja, com a aplicação de 3 camadas). A durabilidade da RU obtida com o uso das soluções experimentais (35%HEMA/65%solventes) aplicadas sobre dentina desmineralizada seca foi avaliada após 24hs , 6 meses ou 1 ano de armazenagem em água deionizada. O valor de RU sofreu uma redução com a referida armazenagem para a maioria das soluções testadas. Os maiores valores de RU foram obtidos para H/M e H/E em todos os períodos avaliados. Este estudo desenvolveu uma linha de raciocínio que empregou a teoria dos parâmetros de solubilidade para descrever e analisar as interações moleculares que ocorrem durante a execução de um procedimento adesivo à dentina, procurando estabelecer as relações de causa e efeito. / The present study aimed to test the effect of the molecular interactions between solvent and pure monomers with demineralized dentin matrix on its mechanical properties, evaporation rate and consequent change in the bond strength (BS). The mechanical properties were determined by measuring the apparent maximum modulus of elasticity (EMax) and stress relaxation (SR). The results indicated that the Emax is both time and solvent dependent; accordingly, the SR was both strain and solvent dependent. The weight loss (%) and evaporation rate of experimental mixtures (35%HEMA/65%solvents) were determined by the measuring of weight loss over time from different surfaces (demineralized dentin cubes x free surface). The overall evaporation rate and weight loss were higher for dentin cubes and dependent of solvents. The bond strength (BS) was determined by the microtensile test. The effects of surface shininess on bond strength of experimental primers to dentin were evaluated. Dentin surfaces were acidetched, primed with experimental mixtures in two (not shiny) or three (shiny) coats. For the all primers the presence of a shiny surface significantly improved resin-dentin bond strengths. The influence of storage time in resin dentin bond strength mediated by experimental HEMA/solvent primers was determined. Part of specimens were tested after 24 hour storage in deionized water (control) and remaining specimens were tested after 6 months and 1 year of storage in the same condition. Water storage resulted in reduced bond strength for most of the primers. This study develops a rationale that employs the solubility parameter theory to describe and analyze molecular interactions that occur during adhesive procedure to dentin, seeking to establish the cause-effect relationship.
200

Influência dos dessensibilizantes dentinários na resistência ao cisalhamento de dois sistemas adesivos na dentina condicionada com ácido fosfórico a 37%

Vera Aun Penteado 18 October 2005 (has links)
Este estudo visou analisar e comparar as resistências adesivas ao cisalhamento das interfaces entre a dentina e uma resina restauradora fotopolimerizável, criadas por dois sistemas adesivos disponíveis no mercado: Scotchbond Multi-Purpose e One-Step, e a influência do pré-tratamento com os dessensibilizantes dentinários Gluma® Desensitizer e Bisblock, usados, respectivamente, após o condicionamento da dentina com ácido fosfórico a 37%. Quarenta terceiros molares foram usados, livres de cáries, cujas camadas de dentina foram expostas numa tentativa de obter-se superfícies planas com smear layer padronizadas. Os sistemas adesivos, após o condicionamento ácido, foram aplicados de acordo com as instruções dos fabricantes, combinados ou não aos dessensibilizantes. A resistência adesiva ao cisalhamento foi medida após a imersão dos corpos-de-prova, resultantes da união de pequenos cilindros de resina composta, fotopolimerizável, à superfície dentinária, em água deionizada a 37C por 7 dias, usando uma Máquina de Ensaios Universal (KRATOS, São Paulo-SP). Os dados foram analisados através dos testes de ANOVA, a um critério de classificação, e Tukey, o qual houve uma diferença significativa entre os grupos (P < 0,001). Na análise dos tipos de falhas o Grupo 2 apresentou 100% de falhas coesivas e o Grupo 4 apresentou 100% de falhas adesivas. Concluiu-se que o uso dos dessensibilizantes influenciou na resistência ao cisalhamento dos dois sistemas adesivos testados, e a aplicação do Gluma Desensitizer, após o condicionamento ácido da dentina, usado previamente ao sistema adesivo Scotchbond Multi-Purpose, resultou em valores de resistência significativamente superiores do que quando não aplicado, ou seja, 19,72750 ± 4,667893 MPa e 27,29000 ± 6,478825 MPa, após a aplicação do dessensibilizante. O Bisblock, aplicado após o condicionamento ácido da dentina e usado previamente ao sistema adesivo One-Step, apresentou valores de resistência significativamente mais baixos do que quando não aplicado, ou seja, 10,06250 ± 4,4361878 MPa e 5,73750 ± 1,552786 MPa. / This study investigated and compared the bond strengths to the interface shear, created between the dentin and a light-cured restorative resin for two adhesive systems commercially available: Scotchbond Multi-Purpose and One-Step, and the influence of the pre-treatment with the dentin desensitizer Gluma Desensitizer and Bisblock, respectively, after the dentin etching with phosphoric acid at 37%. Forty non-carious human third molars were used, whose layers of dentin were exposed in an attempt to obtain flat surfaces with standardized smear layer. The bond systems were applied according to the manufacturer instructions, and, after the acid etching, it was also used the desensitizing systems according to manufacturer instructions. The bond strength to the shear was measured after the immersion of the specimens, resulting from the bond of small resin composite cylinders light-cured to the dentin surface, in deionized water at 37C for 7 days, using a Kratos testing machine (São Paulo - SP). The data were analyzed by one-way ANOVA and Tukey tests and there was a significant difference among the groups (P < 0.001). In the analysis of the failures types, Group 2 showed 100% of failures cohesive and Group 4 showed 100% of failures adhesive. It was concluded that the use of the desensitizers influenced the shear strength of the two adhesive systems tested, and the application of the Gluma Desensitizer, after the dentin acid etching, used previously in the Scotchbond Multi-Purpose adhesive system, resulted in strength values significantly higher than when not applied, that is, 19.72750 '+ou-' 4.667893 MPa. and 27.29000 '+ou-' 6.478825 MPa, after the application of the desensitizer. The Bisblock, applied after the dentin acid etching and used previously to the One-Step adhesive system, showed strength values significantly lower than when not applied, that is, 10.06250 '+ou-' 4.436187 MPa and 5.73750 '+ou-' 1.552786 MPa

Page generated in 0.0492 seconds