• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 839
  • 37
  • 37
  • 37
  • 37
  • 36
  • 29
  • 9
  • 7
  • 6
  • 4
  • 3
  • 3
  • 1
  • 1
  • Tagged with
  • 899
  • 499
  • 251
  • 202
  • 193
  • 178
  • 152
  • 140
  • 140
  • 121
  • 114
  • 97
  • 97
  • 96
  • 94
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
151

Influência do tratamento expectante sobre propriedades acidogênicas e acidúricas de Streptococcus mutans e LLactobacillus acidophilus

Correia, Marília Ferreira [UNESP] 11 March 2014 (has links) (PDF)
Made available in DSpace on 2015-09-17T15:24:19Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-03-11. Added 1 bitstream(s) on 2015-09-17T15:48:01Z : No. of bitstreams: 1 000837199.pdf: 1080798 bytes, checksum: f2ec8aa2deb92d0dae09d3a96a0c2ff0 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A remoção parcial de tecido cariado, realizada por meio do tratamento expectante, apresenta um alto índice de sucesso clínico, além de promover uma redução dos microrganismos presentes na dentina cariada. Porém, a permanência de tais microrganismos geram questões a respeito de certas propriedades que tais bactérias apresentam que as fazem ser capazes de continuar desmineralizando o tecido dentinário. Assim, esse estudo analisou as propriedades acidogênicas e acidúricas de Streptococcus mutans e Lactobacillus acidophilus, além de avaliar alterações clínicas como coloração e consistência e quantificar através de meios de cultura específicos alguns microrganismos presentes nesse tipo de lesão. Para isto, foram selecionados 20 pacientes apresentando molares decíduos com lesões passíveis de receber o tratamento expectante, sendo realizado coletas de lascas de dentina em dois momentos diferentes: na primeira intervenção após a remoção parcial de tecido cariado e na segunda intervenção durante a reabertura da cavidade 90 dias após o selamento provisório da lesão. As amostras coletadas foram cultivadas, identificadas e quantificadas, além de serem analisadas quanto aos testes fenotípicos de acidogenicidade e aciduridade. Os dados foram submetidos a análise estatística, e observou-se que apesar de ocorrer uma diminuição estatisticamente significante no número de microrganismos viáveis analisados, não houve diferença estatística com relação as propriedades acidogênicas e acidúricas de Streptococcus mutans e Lactobacillus acidophilus coletados nos dois momentos especificados. Conclui-se que o tratamento expectante apesar de promover alterações clínicas como escurecimento e endurecimento dentinário, associado com a redução no número de microrganismos viáveis, parece não exercer influência nas características fenotípicas de aciduridade...(Complete abstract electronic access below) / Partial caries removal performed by the stepwise treatment has a high rate of clinical success and also promotes a reduction of microorganisms in carious dentin. However, the permanence of these microorganisms raises the question about certain properties which such bacteria present that make them able to continue the demineralization of the dentin. Thus, the aim of this study was to examine the acidogenic and aciduric properties of Streptococcus mutans and Lactobacillus acidophilus as well as to assess clinical changes in color and consistency of carious dentine and to quantify some microorganisms present in this type of lesion. Therefore 20 patients presenting deep caries lesion in primary molars eligible to receive the stepwise treatment were selected and dentin samples were collected in two different moments: in the first intervention just after partial caries removal and in the second intervention during the reopening of the cavity, 90 days after the temporary sealing of the lesion. The samples were cultured, identified and quantified, and were analyzed for phenotypic tests to available their acidogenicity and aciduricity. Data were statistically analyzed and it was observed that despite a decrease statistically significant in the number of viable microorganisms, there was no statistical difference in the acidogenicity and aciduricity properties of Streptococcus mutans and Lactobacillus acidophilus over the time. It was concluded that the stepwise treatment promoted clinical changes as darkening and hardening of carious dentine and also promoted a reduction in the number of viable microorganisms, although it seemed not to influence the phenotypic characteristics like acidogenicity and aciduricity of the species analyzed during the period of 90 days.
152

Influência do tratamento dentinário com Clorexidina, Ácido Hialurônico ou Vitamina C na resistência adesiva e propriedades mecânicas da camada híbrida

Silva, Patricia Rondon Pleffken da [UNESP] 06 December 2013 (has links) (PDF)
Made available in DSpace on 2014-08-13T14:51:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-12-06Bitstream added on 2014-08-13T17:59:36Z : No. of bitstreams: 1 000776581.pdf: 10189394 bytes, checksum: 53453d9130a3b619a837af68f2b9ac1c (MD5) / O objetivo deste estudo foi avaliar a influencia da Clorexidina, Ácido Hialurônico e Vitamina C na resistência adesiva à dentina e na propriedade mecânica (nanodureza e módulo de elasticidade) da camada híbrida. A dentina superficial de noventa e seis dentes bovinos foi exposta. Os espécimes foram divididos em quatro grupos (n=24) de acordo com o tratamento dentinário: G1 (Controle) - aplicação do sistema adesivo (Adper Single Bond 2); G2 - tratamento com solução de clorexidina a 2% por 1 min + sistema adesivo; G3 - tratamento de solução com Ácido Hialurônico 1% por 1 min + sistema adesivo; G4 - tratamento com solução de Vitamina C (Vit C) 10% por 1 min + sistema adesivo. Após polimerização do sistema adesivo foi aplicado duas camadas de resina composta Filtek 250 (3M ESPE) de forma incremental com auxílio de uma matriz e fotopolimerizada por 20 s cada. Em seguida, os espécimes foram armazenados em água destilada a 37°C por 24 h (n=12) e 6 meses (n=12). Após o período de armazenamento, os espécimes foram seccionados onde se obteve um espécime de aproximadamente 1 mm2 de área. Foram submetidos ao teste de microtração em máquina de ensaio universal (DL-1000, EMIC/10 kgf/ 0,5 mm/min). Cinco espécime de cada grupo armazenado por 6 meses foi submetido ao teste de nanodureza e módulo de elasticidade da camada híbrida. Os dados foram submetidos aos testes estatísticos Anova 2 fatores e Tukey. No grupo após armazenamento 24 h mostraram que os maiores valores foram obtidos nos G1, G2 e G3, mas após 6 meses de armazenamento apenas o G2 e G3 apresentaram os maiores valores. Com relação às propriedades mecânicas o G3 apresentou o maior valor de dureza quando comparado aos demais grupos estudados. Não houve diferença estatística significante quanto ao módulo de elasticidade entre os grupos. Concluimos que a aplicação da clorexidina e ácido hialurônico na dentina foi .... / The aim of this study was to evaluate the influence of chlorhexidine, hyaluronic acid and C vitamin C on dentin bond strength and on the hybrid layer mechanical properties. The buccal surface of ninety six extracted bovine teeth was ground to exposure a flat dentin surface. The specimens were divided in four experimental groups (n=24): G1 (Control) - application of the adhesive system (Adper Single Bond 2); G2: dentin treatment with chlorhexidine 2% for 1 min + adhesive system; G3: dentin treatment with hyaluronic acid 1% for 1 min + adhesive system; G4: dentin treatment with C vitamin 10% for 1 min + adhesive system. After polymerization of the adhesive system, two increments of the composite resin, Filtek Z 350 (3M ESPE), were placed on dentin with the aid of a matrix and polymerized for 20 s each. The specimens were stored in distilled water at 37ºC for 24 h (n=12) and 6 months (n=12). They were then sectioned in order to obtain specimens with an area of approximately 1 mm2. They were submitted to microtensile bond strength tests using a universal testing machine (DL- 1000, EMIC/10 kgf/ 0,5 mm/min). One specimen of each of the groups stored for 6 months was submitted to nanohardness and elasticity module tests for the hybrid layer. Data were analyzed by two-way ANOVA and Tukey's test. Tests performed after 24 h showed higher adhesive bond strength for groups G1, G2 and G3, but after six months the highest values were presented by groups G2 and G3. Nanohardness tests revealed greater resistance for G3 compared to the other groups. Modulus of elasticity was found to be the same for all groups. It could be concluded that the application of chlorhexidine and hyaluronic acid on dentin was effective in keeping high bond strength values after 6 months but regarding the hybrid layer only hyaluronic acid increased nanohardness
153

Efeito longitudinal de tratamentos de superfície modificados por Nd:YAG laser na permeabilidade dentinária

Esteves, Stella Renata Machado Silva [UNESP] 17 December 2013 (has links) (PDF)
Made available in DSpace on 2014-08-13T14:51:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-12-17Bitstream added on 2014-08-13T17:59:33Z : No. of bitstreams: 1 000776704.pdf: 1940929 bytes, checksum: d4c86f66952020d3ca68e98798ef8d5c (MD5) / A hipersensibilidade dentinária acomete grande parte da população e gera muito desconforto. A maioria dos tratamentos baseia-se na utilização de agentes de redução da permeabilidade que tem seu efeito relacionado a fatores individuais e baixa longevidade. O objetivo deste estudo foi avaliar, in vitro, a eficácia e longevidade de tratamentos para redução da permeabilidade dentinária, tais como o flúor, o adesivo e a desproteinização do colágeno, associados ou não ao Nd:YAG laser por meio da movimentação do fluido dentinário medido pela máquina de permeabilidade (Odeme, Brazil). Setenta espécimes de dentina bovina com 6mm de diâmetro e 1 mm de espessura foram divididos em 7 grupos conforme o tratamento realizado. Grupo C: controle, sem tratamento; Grupo F: verniz com flúor; Grupo FL: verniz com flúor + Nd:YAG laser; Grupo A: adesivo Scotchbond Universal; Grupo AL: adesivo + Nd:YAG laser; Grupo D: 10% de NaOCl + adesivo; Grupo DL: 10% NaOCl + adesivo + Nd:YAG laser. Os espécimes tiveram a permeabilidade dentinária medida em 4 momentos: com a presença de smear layer na parte oclusal (Permeabilidade Mínima); depois da aplicação de EDTA por 1 min (Permeabilidade Máxima); após os tratamentos e; após o desafio erosivo/abrasivo, para analisar a efetividade e durabilidade de cada tratamento. Os modelos estatísticos RM ANOVA (2 fatores) e Tukey (α=0,05) foram aplicados. Os tratamentos foram efetivos na redução da permeabilidade com exceção do grupo FL. Os tratamentos associados ao laser tiveram redução significativa da permeabilidade, exceto para o grupo FL; o grupo AL foi o tratamento mais eficaz na análise imediata pós-tratamento, e o grupo DL foi o mais eficaz pós-desafio (longitudinal). Podemos concluir que somente o tratamento DL foi eficaz longitudinalmente / Dentin hypersensitivity affects a large population and generates a lot of discomfort. Most treatments are based on the use of agents to reduce permeability with their effect related to individual factors and with low longevity. The aim of this study was to evaluate in vitro the efficacy and longevity of treatments for reducing dentin permeability, such as fluoride, adhesives and collagen deproteinization, associated or not with Nd : YAG laser by measuring the dentinal fluid flow in a permeability machine ( Odeme , Brazil). Seventy bovine dentin specimens of 6mm diameter and 1 mm thickness were divided into 7 groups according to treatment: Group C: control without treatment; Group F: fluoride varnish; Group FL: fluoride varnish + Nd:YAG laser, Group A: Scotchbond Universal, Group AL: adhesive + Nd:YAG laser, Group D: 10 % NaOCl + adhesive; group DL: 10 % NaOCl, adhesive + Nd:YAG laser. The specimens had dentin permeability measured in 4 phases: in the presence of the occlusal smear layer (Minimum Permeability), after EDTA application for 1 min (Maximum Permeability), after the treatments and after erosion / abrasive challenge; in order to analyze the effectiveness and durability of each treatment. RM ANOVA (2 factors) and Tukey (α = 0,05) were applied. Treatments were effective in reducing permeability except for group FL; the laser treatments were associated with significant reduction in permeability, except for the FL group; group AL was the most effective treatment in the immediate post-treatment analysis and; the DL group was the most effective post- challenge (longitudinal). We conclude that only the DL treatment was effective longitudinally
154

Citotoxidade de cimentos resinosos sobre célular obtidas da polpa de dentes humanos (HDPCs) e odontoblastóides (MDPC-23)

Pontes, Elaine Cristina Voltolini [UNESP] 25 February 2014 (has links) (PDF)
Made available in DSpace on 2014-12-02T11:16:38Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-02-25Bitstream added on 2014-12-02T11:21:06Z : No. of bitstreams: 1 000796605.pdf: 2231117 bytes, checksum: 2cb8d762ad76e855d47d13daf8e4e4f2 (MD5) / O objetivo deste estudo foi avaliar a citotoxicidade de cimentos resinosos quando aplicados sobre cultura de células odontoblastóides (MDPC-23) e pulpares humanas (HDPC). Os seguintes grupos foram formados: G1 - controle (sem tratamento); G2 - Rely X Luting 2; G3 - Rely X U200; G4 - Rely X ARC. Corpos de prova padronizados, preparados com os cimentos, foram imersos em 1 mL de meio de cultura (DMEM) por 24hs para obtenção dos extratos (DMEM + componentes liberados dos cimentos). Após aplicar os extratos sobre as células por 24hs, a viabilidade (MTT assay) e tipo de morte celular (Anexina/PI), bem como a morfologia das células (MEV) foram avaliados. Os dados obtidos foram submetidos à análise estatística de Kruskal-Wallis complementada por Mann-Whitney (α=5%). A análise química dos extratos foi realizada por cromatografia liquida de alta performance (HPLC). Nos grupos G2, G3 e G4, observou-se redução de 95,8%, 31,5% e 22,7% na viabilidade das células MDPC-23, respectivamente. Redução de 89,4% para G2 e aumento em 11,3% e 29% para G3 e G4, respectivamente, foram observados para as HDPCs. Para as células MDPC-23, redução significativa de viabilidade ocorreu em G2 e G3 quando comparado à G1; todavia, para as HDPCs esta redução foi observada apenas em G2 (p<0,05). Para ambas as culturas usadas no estudo, ocorreu 100% de morte celular por necrose apenas em G2, onde o pH do extrato era ácido. Em G3, onde uma pequena quantidade de TEGDMA foi detectado no extrato, houve reduzida morte celular por necrose e discreta alteração morfológica nas células. Todavia, nenhum dano celular ocorreu em G4. De maneira geral, a células MDPC-23 são mais sensíveis do que as HDPCs. Concluiu-se que apenas o cimento Rely X Luting 2 causou intenso efeito citotóxico para ambas culturas de células pulpares usadas neste estudo. Rely X U200 apresentou discreta citotoxicidade, enquanto o cimento Rely X ARC não foi tóxico para as células pulpares... / The aim of this study was to evaluate the cytotoxicity of luting cements on cultured MDPC-23 odontoblast-like cells and human dental pulp cells (HDPCs). The following groups were formed: G1 - control (no treatment), G2 - Rely X Luting 2, G3 - Rely X U200; G4 - Rely X ARC. Standard round specimens prepared with resin cements were immersed in 1 ml of culture medium (DMEM) for 24 hours to obtain the extract (DMEM + components released from the cement). After applying the extracts to the cells for 24 hours, the viability (MTT assay) and type of cell death (Annexin/PI) as well as cell morphology (SEM) were evaluated. The data obtained was submitted to Kruskal-Wallis statistical analysis complemented by Mann-Whitney test (α=5%). The chemical analysis of the extracts was performed by high performance liquid chromatography (HPLC). In G2, G3 and G4, there was a reduction of 95.8 %, 31.5 % and 22.7 % in the MDPC-23 cells viability, respectively. A reduction of 89.4 % for G2, as well as an increase of 11.3 % and 29% for G3 and G4 was observed for the HDPCs, respectively. Significant reduction of MDPC-23 viability occurred for G2 and G3 compared to G1. However, for HDPCs this reduction was only observed in G2 (p<0.05). For both cell cultures used in this study, there was 10 % of cell death by necrosis only in G2, in which the pH of the extract was acid. In G3, where a small amount of TEGDMA was detected in the extracts, there was reduced cell death by necrosis and a discrete morphological alteration in cells. No cellular damage occurred in G4. In general, the MDPC-23 cells are more sensitive than HDPCs against the toxicity of resin cement components. It was found that only the Rely X Luting cement caused intense cytotoxic effect for both pulp cell cultures used in this study. Rely X U200 showed mild cytotoxicity, whereas the cement Rely X ARC was not toxic to the pulp cells.
155

Avaliação da microinfiltração marginal em restaurações de resina composta, quando o colágeno dentinário é mantido ou eliminado após o condicionamento ácido, alterando-se o período de armazenamento e a termociclagem

Torres, Carlos Rocha Gomes [UNESP] 15 March 2002 (has links) (PDF)
Made available in DSpace on 2015-01-26T13:21:31Z (GMT). No. of bitstreams: 0 Previous issue date: 2002-03-15Bitstream added on 2015-01-26T13:30:16Z : No. of bitstreams: 1 000148105.pdf: 6603398 bytes, checksum: b573466a374fbc1a46aedaa48a08fe0f (MD5) / O objetivo deste estudo foi avaliar o grau de microinfiltração marginal em restaurações de resina composta, diante das variáveis remoção ou não do colágeno dentinário após o condicionamento ácido, e utilização ou não de uma camada de resina composta fluida sobre a dentina desproteinizada, alterando-se os seguintes fatores: a)tempo de armazenagem (0, 6 e 12 meses): b) ciclagem térmica (500, 1.500 e 2.500 ciclos). Para tal, 180 dentes bovinos receberam preparos classe V ao nível da junção amelocementária. Eles foram divididos em três grupos: grupo C - foi aplicado o sistema adesivo Single Bond (3M), segundo as recomendações do fabricante, e a seguir procedida a restauração com a resina composta Z250 (3M); grupo H - após o condicionamento ácido foi aplicada uma solução aquosa de NaOCI a 10% por 1 min, e então aplicado o adesivo Single Bond e a resina composta Z250; grupo HF- semelhante ao grupo H, exceto que após a polimerização do adesivo, uma fina camada de resina composta fluída Natural Flow (DFL) foi aplicada e polimerizada, antes da inserção da resina Z250. Todos os espécimes sofreram 500 ciclos ténnicos (5 ±5°C a 55 ±5°C). Os espécimes em cada grupo foram divididos ao acaso em três subgrupos. No primeiro, a microinfiltração marginal foi avaliada após 24h. No segundo, os espécimes permaneceram imersos em água destilada contendo 0,4% de azida sódica em estufa a 37°C por seis meses, sendo que após este período sofreram mais 1.000 ciclos térmicos. No terceiro, os espécimes permaneceram imersos por 12 meses, e receberam mais 1.000 ciclos térmicos a cada 6 meses, totalizando 2.500 ciclos. Após os respectivos períodos de armazenagem, a microinfiltração marginal foi avaliada pelo método do nitrato de prata seguido pela diafanização. Os espécimes foram analisados em estereomicroscópio e receberam escores de 0 a 4. Os dados... / The aim of this study was to evaluate the marginal microleakage in composite resin restorations. under the variables removal or not of the dentin collagen after the acid conditioning, and utilization or not of a flowable composite resin layer on deproteinized dentin, changing the factors: a) storage time (0, 6 and 12 months); b) thermal cycling (500, 1.500 and 2.500 cycles). For this, 180 bovine teeth received class V cavit preparation at cementun-enamel junction. They were assigned to three groups: group C - was applied the Single Bond adhesive system (3M), according to manufacturer instructions, and restored with Z250 composite resin (3M); group H - after the acid conditioning was applied a 10% NaOCI aqueous solution for 1min, and then applied the adhesive and restored with Z250; group HF - like the group H, except that after the adhesive polymerization. a thin layer of a flowable composite resin Natural Flow (DFL) was applied and polimerized, before the placement of Z250. AIl specimens received 500 thermal cycles (5±5'C to 55±5-'C). The specimens in each group were randomly assigned to three subgroups. In the first, the microleakage was evaluated after 24h. In second, the specimens were stored in distillate water containing 0,4% of sodium azide in stove at 37'C, for 6 months, and after this time received more 1.000 thermal cycles. In the third, the specimens were stored for 12 months, and they received more 1.000 thermal cycles for each 6 months. At the end of each storage time, the microleakage was evaluated by the silver nitrate method, followed by cleaning technique. The specimens were analyzed in stereomicroscope and received scores of 0 to 4. The data were submitted to statistical analysis, using the Kruskal Wallis's and Multiple Comparisons tests. After 6 months of storage, the groups H and HF showed falls in microleakage, while the group C didn't showed significant differences
156

Influência do instrumento de preparo protético e da estratégia de cimentação adesiva na resistência de união à dentina

Souza, Marco Antonio Pereira Morais de 19 July 2017 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Ciências da Saúde, Programa de Pós-Graduação em Ciências da Saúde, 2017. / Submitted by Raquel Almeida (raquel.df13@gmail.com) on 2017-11-24T16:10:06Z No. of bitstreams: 1 2017_MarcoAntonioPereiraMoraisdeSouza.pdf: 1980984 bytes, checksum: 814efed68e5ebf889dbd6a4805857f49 (MD5) / Approved for entry into archive by Patrícia Nunes da Silva (patricia@bce.unb.br) on 2017-12-20T11:56:04Z (GMT) No. of bitstreams: 1 2017_MarcoAntonioPereiraMoraisdeSouza.pdf: 1980984 bytes, checksum: 814efed68e5ebf889dbd6a4805857f49 (MD5) / Made available in DSpace on 2017-12-20T11:56:04Z (GMT). No. of bitstreams: 1 2017_MarcoAntonioPereiraMoraisdeSouza.pdf: 1980984 bytes, checksum: 814efed68e5ebf889dbd6a4805857f49 (MD5) / Os diferentes instrumentos disponíveis para o preparo protético podem produzir padrões de smear layer distintos e alterar a interação da dentina com os sistemas adesivos e cimentos resinosos. Os objetivos da presente pesquisa foram caracterizar a smear layer decorrente do preparo protético com diferentes instrumentos e avaliar a resistência de união à dentina de diferentes combinações de instrumentos de preparo protético e estratégias de cimentação adesiva. Material e método: 50 terceiros molares humanos foram utilizados para o estudo. 4 discos de dentina foram utilizados para a caracterização sob microscopia eletrônica de varredura da morfologia da smear layer produzida pelos diferentes instrumentos de preparo protético testados, ponta diamantada rugosa (C), ponta diamantada fina (F), broca multilaminada (L) e jateamento com óxido de alumínio (O). 96 hemi-dentes tiveram dentina coronária média exposta e planificada com lixas. A dentina foi então preparada com os quatro instrumentos para preparo protético (C, F, L e O). Três diferentes estratégias de cimentação foram utilizadas, condicione e lave (ER), autocondicionante (SE) e autoadesiva (SA) para cimentar à dentina preparada em blocos de resina composta. Os hemi-dentes (n=8 para cada combinação de instrumento e estratégia de cimentação) foram então seccionados em palitos e submetidos ao teste de resistência de união à microtração. Os dados foram submetidos à análise estatística por ANOVA a 2-critérios e teste post hoc de Tukey (α=0,05). Os padrões de fratura foram analisados sob microscopia óptica e microscopia eletrônica de varredura (MEV). Resultados: O tipo de instrumento utilizado promoveu smear layers com características morfológicas distintas. A variável instrumento de preparo não teve efeito estatisticamente significativo na resistência de união à dentina (p=0,531). A variável estratégia de cimentação apresentou diferença estatisticamente significativa entre grupos (p<0,001). As estratégias de cimentação ER e SE apresentaram resistência de união significativamente superior à estratégia SA. Conclusões: Dentro das limitações deste estudo in vitro, o uso de diferentes instrumentos de preparo não alterou a resistência de união de restaurações indiretas à dentina para as estratégias de cimentação testadas. A cimentação autoadesiva promoveu valores de resistência de união à dentina inferiores às estratégias condicione e lave e autocondicionante. / The different tools available for teeth preparation for dental prosthetics can produce different patterns of smear layer and alter the interaction of the dentin with the resin cements and bonding agents. The objectives of the present research were to characterize the residual smear layer that results from the teeth preparation with different burs and air abrasion and evaluate the tensile bond strength to the dentin with the association of different resin cementation strategies and different preparation instruments. Materials & Methods: 50 human fresh extracted teeth were used. 4 dentin discs were used to characterize the smear layer morphology produced by the tested tools under scanning eletron microscopy, coarse diamond bur (C), fine diamond bur (F), multibladed bur (L) and air abrasion with aluminium oxide (O). 96 hemi-teeth were ground flat to expose mid-coronal occlusal dentin surface with grit SiC paper. Dentin was then further prepared with four different preparation instruments (C, F, L e O). Three different cementation protocolos were used, etch & rinse (ER), self- etching (SE) and self-adhesive (SA) to bond resin-based composite blocks to the dentin surface. Simple shaped specimens were fabricated and microtensile bond strengths were determined. The sub- sequent debond pathway and micromorphological structures of representative dentin surfaces were examined under scanning electron microscopy (MEV). 2- way ANOVA and post hoc Tukey (α=0,05) were used to data analysis. Results: The instrument used in teeth preparation produced smear layers with distinct morphologic characteristics. The instrument variable did not produce significant satistical differences in the dentin bond strength (p=0,531). The cementation strategy variable presented significant statistical differences between the groups (p<0,001). ER and SE strategies produced higher bond strength values in comparison to the SA strategy. Conclusions: Within the limitations of our in vitro study, the use of different teeth preparation instruments did not alter the bond strength of indirect resin composites to the cementation strategies tested. The SA strategy resulted in lower bond strength results then those produced with ER and SE strategies.
157

Micromorfologia e resistência da união à dentina decídua tratada com dois sistemas adesivos estudo in vitro

Casagrande, Luciano January 2003 (has links)
O objetivo deste estudo in vitro foi avaliar a interação de dois sistemas adesivos (Scotchbond Multi-Purpose - 3M; Clearfil SE Bond - Kuraray) aplicados à dentina de dentes decíduos, através do ensaio de resistência da união à microtração, e da análise da micromorfologia da interface adesiva. Foram confeccionadas duas cavidades ocluso-proximais padronizadas (tipo slot vertical) na mesial e distal de dezoito molares decíduos hígidos. Cada um dos sistemas adesivos foi aplicado em uma das cavidades do mesmo dente. As cavidades foram restauradas com resina composta (Filtek Z 250 – 3M) pela técnica incremental, sendo cada camada fotopolimerizada por 20 s, utilizando uma fonte de luz visível (XL 2500 - 3M). Os dentes foram armazenados por uma semana em água destilada a 4o C e seccionados no sentido vestíbulo-lingual para análise isolada de cada restauração. Cada uma destas foi seccionada em fatias de 0,7 mm de espessura e, em seguida, efetuou-se uma constrição (1 mm) na região da interface de união (parede axial) para obtenção de uma área adesiva com aproximadamente 0,7 mm2. Os corpos-de-prova foram fixados isoladamente em um dispositivo conectado em uma máquina de ensaio universal (Instron – modelo 4411) e submetidos à tração com velocidade de 0,5 mm/min. As superfícies das secções fraturadas foram avaliadas ao MEV (Jeol –5600 LV) e categorizadas em relação aos padrões de fratura ocorridos. Adicionalmente, superfícies planas contendo a interface de união foram preparadas com lixas de carbureto de silício (granulação 1000) e polimento com pastas de diamante (6, 3, 1 e 0,25 µm). Após desidratação em sílica coloidal em temperatura ambiente por 24 h, as superfícies foram cobertas com liga de ouro e, a micromorfologia da união formada na parede axial das restaurações ocluso-proximais, analisadas ao MEV (Jeol –5600 LV). Os resultados do ensaio de resistência de união foram submetidos à análise estatística utilizando o teste t de student em nível de 5% de significância, e os tipos de fraturas e os aspectos micromorfológicos da interface adesiva submetidos à avaliação descritiva. Os valores médios de resistência de união dos adesivos Scothbond Multi-Purpose (21,84±9,90 MPa) e Clearfil SE Bond (25,19±5,33 MPa) não apresentaram diferenças estatisticamente significantes entre si (p=0,27). A análise do tipo de fratura revelou uma maior quantidade de falhas na região de dentina desmineralizada (G1: SMP) e na porção superior da camada híbrida (G2: CSE). A interface de união, em ambos os grupos, foi caracterizada pela formação da camada híbrida, projeção de prolongamentos resinosos adaptados à dentina e com direcionamento relacionado à disposição dos túbulos dentinários na área da cavidade avaliada.
158

Avaliação da eficácia do etanol na resistência de união à dentina utilizando adesivo convencional e autocondicionante sob envelhecimento /

Souza, Mauricio Yugo de. January 2016 (has links)
Orientador: Rebeca Di Nicoló / Coorientador: Prof. Adj. Eduardo Bresciani / Banca: Alessandra Bühler Borges / Banca: Levy Anderson César Alves / Resumo: O objetivo deste estudo foi avaliar o efeito do etanol na longevidade de união de diferentes modos de aplicação do sistema adesivo ao substrato dentinário bovino, através do teste de microtração. Foram utilizados 80 incisivos bovinos, os quais tiveram a superfície dentinária da face vestibular exposta e a padronização da smear layer. Após a padronização, os espécimes foram divididos aleatoriamente em 2 grupos, Grupo Com Etanol (GE) e Grupo Sem Etanol (GS) e após, subdivididos de acordo com a forma de aplicação do sistema adesivo, Condicionamento Ácido Convencional (GEC, GSC) e Autocondicionante (GEA, GSA). Sobre a superfície tratada foram confeccionados blocos de resina com auxílio de matriz de silicone e armazenados em água deionizada a 37 ºC, por um período de 48 h. Após a cura da resina, metade dos espécimes foi submetida ao envelhecimento termomecânico resultando nos seguintes grupos (n= 10): GEC sem Envelhecimento (GECSE), GEC Envelhecido (GECE), GSC Sem Envelhecimento (GSCSE), GSC Envelhecido (GSCE), GEA Sem Envelhecimento (GEASE), GEA Envelhecido (GEAE), GSA Sem Envelhecimento (GSASE) e GSA Envelhecido (GSAE). Foram obtidos palitos resina/dentina com área adesiva medindo aproximadamente 1x1 mm, e submetidos ao teste de microtração em máquina de ensaios Universal DL-200MF (EMIC). Os dados foram analisados pelos testes ANOVA a três fatores e Tukey (α = 5%). Houve interação entre os três fatores (p = 0,0003). O modo de aplicação foi semelhante, exceto para o GSAE que fo... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to evaluate the effect of ethanol on the longevity on adhesion by different application ways of adhesive system to bovine dentin substrate, through the microtensile test. Eighty bovine incisors were used, which had buccal dentin exposed and the standardization of smear layer obtained by sandpaper polishing (600 SiC, Fepa-P). After standardization, the specimens were randomly divided into 2 groups, With Ethanol Group (GE) and No Ethanol Group (GS) and further, subdivided according to the application ways into: Conventional Acid conditioning (GEC, GCH) and self-etching (GEA, GSA). Resin blocks were built over the treated surface using a silicon mold and specimens were stored in deionized water at 37ºC for 48 hours. After resin lightcuring, half of the specimens was subjected to thermomechanical aging resulting in the following groups (n = 10): GEC No Aging (GECSE), GEC Aged (GECE), GSC No Aging (GSCSE), GSC Aged (GSCE), GEA No Aged (GEASE), GEA Aged (GEAE), GSA No Aging (GSASE) e GSA Aged (GSAE). Resin/Dentin sticks measuring approximately 1x1 mm were obtained and subjected to microtensile test in universal testing machine Universal DL-200MF (EMIC). Data were analyzed by three-way ANOVA and Tukey tests (α = 5%). There was interaction between the three factors (p = 0.0003). The application way was similar except for GSAE which was highest than GSCE. The use of ethanol resulted in higher values of microtensile except for GECSE which was similar to GSCSE.... (Complete abstract click electronic access below) / Mestre
159

Efeito transdentinário do LED em diferentes comprimentos de onda sobre células odontoblastóides

Turrioni, Ana Paula Silveira [UNESP] 25 July 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:48Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-07-25Bitstream added on 2014-06-13T19:15:18Z : No. of bitstreams: 1 turrioni_aps_me_arafo.pdf: 6913344 bytes, checksum: d860b5c16f62f7513a0953411968f01f (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Pesquisas recentes demonstraram que a irradiação transdentinária da polpa pode resultar em aumento na síntese de matriz de dentina e redução na resposta inflamatória local. Entretanto, os mecanismos que regem estes processos permanecem desconhecidos. Assim, o objetivo desta pesquisa foi investigar o efeito transdentinário do LED, em três comprimentos de onda (CO: 455nm, 630nm e 850nm) e duas doses de energia (DE: 4J/cm2 e 25 J/cm2), sobre células odontoblastóides MDPC-23 cultivadas em discos de dentina (molares humanos) com 0,2 mm de espessura. Foram realizadas análises do metabolismo celular (SDH), proteína total (PT) e fosfatase alcalina (ALP), através dos ensaios de MTT, Read Northcote e Ponto Final, respectivamente. O ensaio de RT-PCR foi aplicado para avaliação da expressão dos genes que codificam para colágeno tipo I (Col-1), fibronectina (FN) e fosfatase alcalina (ALP). Além disso, foi realizada a análise da morfologia celular em Microscopia Eletrônica de Varredura (MEV). Para a produção de PT, os resultados não apontaram diferença estatisticamente significante entre os grupos irradiados e controle (Mann-Whitney, p>0,05). Entretanto, para o metabolismo celular, o grupo irradiado com LED no CO de 630 nm, na DE de 25 J/cm2, obteve melhores resultados (aumento de 21,8 %), com diferença significante quando comparado ao grupo controle (Mann-Whitney, p<0,05). Para a produção de fosfatase alcalina, houve aumento significante pra todos os parâmetros utilizados (Mann-Whitney, p<0,05), com exceção da luz azul na dose de 4 J/cm2 (Mann-Whitney, p>0,05). Na análise por RT-PCR, houve maior expressão de Col-1 para o LED infravermelho na dose de 4 J/cm2. Um maior número de células MDPC-23 com morfologia normal aderidas aos discos de dentina, semelhante ao grupo controle, foi... / Several studies have demonstrated that the transdentinal irradiation of dental pulp may increase the dentin matrix synthesis as well as decrease the local inflammatory reaction. However, the mechanisms that regulate these processes remain unknown. Therefore, the objective of this in vitro study was to investigate the transdentinal effect of LED irradiation at three different wavelengths (λ= 455, 630 and 850 nm) and two doses (4J/cm2 and 25 J/cm2) on odontoblast-like cells seeded on 0.2-mm-thick dentin disks obtained from sound human molars. Cell metabolism (MTT), alkaline phosphatase expression (ALP), total protein synthesis, and cell morphology (MEV) were evaluated. The expression of genes that encode for collagen type-1 (Col-1), fibronectin (FN) and alkaline phosphatase (ALP) was analyzed by RT-PCR. For total protein synthesis, the results showed no statistical difference among irradiated and control groups (Mann-Whitney test, p>0.05). However, for cellular metabolism, the group irradiated with 630 nm LED (dose of 25 J/cm2) showed better results (21,8% increase), with significant difference when compared to control group (Mann-Whitney test, p<0.05). For alkaline phosphatase activity, a significantly increase was observed for all parameters (Mann-Whitney test, p<0.05), except for the blue light at a dose of 4 J/cm2 (Mann-Whitney test, p>0.05). RT-PCR showed a higher expression of Col- 1 for the infrared LED at a dose of 4 J/cm2. A larger number of MDPC-23 cells with normal morphology adhered to the dentin discs was observed after irradiation with 25 J/cm2 when compared to 4 J/cm2, for all wavelengths evaluated. It may be concluded that LED irradiation was effective for transdentinal cell biostimulation and the cellular response was dose and wavelength-dependent.
160

Avaliação in vitro da dissolução de um Biosilicato® sobre a superfície dentinária: análise por meio de microscopia eletrônica de varredura

Pinheiro, Michele Carolina [UNESP] 19 April 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-04-19Bitstream added on 2014-06-13T20:08:37Z : No. of bitstreams: 1 pinheiro_mc_me_arafo.pdf: 512491 bytes, checksum: 7c0cc39d1c41c985914ef27350be16db (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O tratamento da hipersensibilidade dentinária cervical ainda é tema de diversos estudos em odontologia, pois um resultado permanente e satisfatório para essa sintomatologia dolorosa ainda não foi encontrado. Uma possibilidade nova de tratamento pode ser a utilização de vidros bioativos, que podem formar hidroxicarbonatoapatita sobre a superfície dentinária e obliterar os túbulos dentinários, no entanto, as formulações disponíveis deste material apresentam inconvenientes que dificultam sua aplicação sobre a superfície dentinária. Este estudo buscou avaliar a dissolução das partículas de uma vitrocerâmica modificado, denominado Biosilicato®, sobre a superfície dentinária, em diferentes veículos de preparo e formas de aplicação. Foram obtidos espécimes de dentina para a aplicação do produto testado e divididos em grupos que variavam quanto à forma de aplicação do Biosilicato® (escova de Robinson ou microbrush) e veiculo utilizado para a aplicação do produto (água ou flúor). Após a aplicação do produto sobre os espécimes estes foram imersos em saliva artificial e deixados em repouso em diferentes tempos: 0 minuto; 15 minutos; 30 minutos; 1 hora; 2 horas; 12 horas e 24 horas e depois levados para secar antes de serem analisadas no microscópio eletrônico de varredura. Após a obtenção das fotomicrografias, estas foram examinadas por um examinador calibrado e cego que atribuiu a elas um escore que variou de 1 a 3, segundo um “Índice de Dissolução de Partículas”. A análise estatística não mostrou diferenças entre os meios utilizados para a dissolução do Biosilicato® e nem entre os métodos utilizados para sua aplicação. Não foram encontradas diferenças estatísticas entre os grupos em nenhum dos tempos analisados, no entanto uma diferença estatística foi encontrada... / Treatment of cervical dentin hypersensitivity is still the subject of several studies in dentistry, as a result of continuous and satisfactory to the painful symptoms that have not been found. A new possibility of treatment may be the use of bioactive glasses, which can form hidroxicarbonatoapatita on the dentin surface and obliterate the tubules, however, the formulations of this material available have drawbacks that hinder its application on the dentin surface. This study investigates the dissolution of particles of a modified ceramic, called Biosilicato ® on the dentin surface at different vehicle preparation and application methods. We obtained specimens of dentin to the application of the product tested and divided into groups that differed as to the application of Biosilicato ® (Robinson bristle brush or microbrush) and vehicle used for the application of the product (water or fluorine). After applying the product on these specimens were immersed in artificial saliva and left to stand at different times: 0 minutes, 15 minutes, 30 minutes, 1 hour, 2 hours, 12 hours and 24 hours and then taken to dry before be analyzed in a scanning electron microscope. After obtaining the photomicrographs, they were examined by one blinded and calibrated examiner who gave them a score ranging from 1 to 3, according to an Index of Dissolution of Particles. Statistical analysis showed no differences between the means used for the dissolution of Biosilicato ®, nor between the methods used for its implementation. There were no statistical differences between groups in any of the periods analyzed, but a statistical difference was found between the times of 1 hour and 24 hours for the group Robinson bristle brush with fluoride and between times of 15 minutes and 24 hours for microbrush group with fluorine.

Page generated in 0.1012 seconds