• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 17
  • 2
  • Tagged with
  • 19
  • 8
  • 8
  • 6
  • 6
  • 6
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Efeito da sinterização da cerâmica no desajuste marginal de coroas metalocerâmicas de níquel-cromo e cobalto-cromo / The effect of ceramics sintering in the marginal misfit on nickel-chromium and cobalt-chromium metal-ceramic crowns

Ana Paula Dias 11 December 2013 (has links)
A adaptação marginal é fundamental para o sucesso clínico e longevidade das coroas metalocerâmicas. O objetivo deste trabalho foi avaliar, por meio de microscopia óptica, o desajuste marginal de copings metalocerâmicos obtidos com as ligas metálicas de Ni-Cr [Verabond II e experimental (SR)] e Co-Cr (Keragen). As leituras foram realizadas antes da sinterização (T1), após a sinterização do opaco (T2) e após a sinterização da cerâmica (T3). A partir de uma matriz metálica e uma contra-matriz de teflon, encaixada sobre o preparo da matriz, foram obtidos 30 padrões de resina acrílica Duralay/cera com espessura de 0,7 mm (n=30), que foram incluidos em anel com revestimento Microfine (Talladium). Após a fundição, os copings foram desincluídos, jateados e usinados. Cada copings, adaptado à outra matriz metálica por meio de um padronizador da pressão de assentamento, foi levado ao microscópio óptico. Foram selecionados dois pontos equidistantes de um ponto selecionado no copings, que representava ¼ de volta no dispositivo de leitura, totalizando 8 leituras por etapa em cada copings. Os dados de desajuste marginal (μm) foram analisados estatisticamente pelos testes ANOVA e Bonferroni (α=0,05). Os resultados mostraram que houve diferença para os fatores: tempo (p=0,00) e liga metálica (p=0,001). Com relação aos tempos, após a aplicação da cerâmica, houve maior desajuste marginal (132 μm) que após a sinterização de opaco (111,81) e antes da sinterização (90,44), com diferença entre essas duas etapas. Com relação às ligas metálicas, a liga experimental SR apresentou o menor desajuste marginal (79,75 μm) que as ligas de Ni-Cr (120,23 μm) e Co-Cr (134,28 μm) que não apresentaram diferença entre si. Não houve diferença significativa para as interações (p=0,834). Conclui-se que o desajuste marginal aumenta após as sinterizações da cerâmica e a liga experimental SR pode ser utilizada com segurança para confecção de restaurações metalocerâmicas, por apresentar os melhores resultados entre as ligas utilizadas. / The good marginal fit is a critical point for the clinical success of metal-ceramic crowns after definitive cementation. The knowledge of alloys properties, their interference factors and materials development allows the creation of new crowns within clinically acceptable marginal fit, factor that enables a good periodontal restorations performance and also prevents caries recurrences in cementation line. The present study evaluated, by optical microscopy, marginal fit in metal-ceramic crowns fused with three different alloys; Nickel-Chromium (Verabond II), Cobalt- Chromium (Keragen) and a experimetal Nickel-Chromium (SR) alloy in three distinct stages; after the cast (T1), after opaque layer application (T2) and after ceramic coating (T3). Were selected two equidistant points in a metal coping that representing ¼ turn on the measurement device, in a total of 8 measurements for coping in each step that results in a misfit average. Comparisons were performed using a parametric test for independent data (ANOVA), followed by Bonferroni test where applicable. The level of significance was set at 5%. The results showed there were statistical differences for such factors: time (p = 0.00) and alloy (p = 0.001). In relation to time, after ceramics application, there was higher marginal misfit (132 μm) than after opaque sintering (111.81 μm) and before sintering (90.44 μm) with differences between these two steps. In relation to alloys, the experimental SR alloy showed the lower marginal misfit (79.75 μm) than Ni-Cr alloys (120.23 μm) and Co- Cr (134.28 μm) and there was no statistical difference for these experimental groups There was no significant difference for interaction (p = 0.834). In conclusion the marginal misfit increases after ceramics sintering. Experimental SR alloy showed the best results among the alloys and can be safely used to metal ceramic restorations.
12

Desajuste del comportamiento psicosocial en estudiantes del IV y V ciclos de educación primaria en una institución educativa estatal, Lambayeque durante agosto-diciembre 2018

Sandoval Valenzuela, Carolain Alessandra January 2019 (has links)
La preadolescencia y adolescencia son etapas que se caracterizan principalmente por presentar actitudes de rebeldía frente a los adultos, defensa de sus propias ideas, establecimiento de su grupo social, preocupación por el físico, inquietud por la opinión que tienen los demás acerca de ellos, entre otros. Comportamientos que para la mayoría de padres resulta complicado entender cabalmente y asumir su propio rol; en consecuencia, desatienden a sus hijos en cuanto al apoyo emocional, a la manifestación de cariño y afecto, a la motivación para su integración al ámbito escolar, etc., aspectos que podrían convertir al individuo más vulnerable a un desajuste en su comportamiento psicosocial. En este contexto, se realizó esta investigación que tuvo por objetivo general determinar los niveles y dimensiones de desajuste del comportamiento psicosocial en estudiantes del IV y V ciclos de educación básica regular de una Institución Educativa Estatal de Lambayeque durante agosto –diciembre 2018, y como objetivos específicos: estimar los niveles de desajuste y dimensiones del comportamiento psicosocial de los estudiantes según sexo y ciclo de estudios, así como describir los factores sociodemográficos. El estudio fue de tipo descriptivo, no experimental, participaron 203 estudiantes de ambos sexos. El instrumento que se aplicó fue el Inventario de desajuste del comportamiento psicosocial (INDACPS-niños), el mismo que obtuvo una confiabilidad de ,890 y una validez de 79,69 %. Los resultados revelan que los estudiantes de ambos ciclos de educación primaria, muestran un nivel medio de desajuste del comportamiento psicosocial. Según sexo, no existen diferencias significativas; y en cuanto al ciclo de estudio, los estudiantes del IV ciclo presentan más dimensiones en el nivel medio de desajuste que los del V ciclo.
13

Avaliação biomecânica de prótese parcial fixa com cantilever sobre implantes em região posterior da mandíbula: estudo comparativo in vitro / Biomechanical evaluation of implant-supported cantilever fixed partial denture in posterior region of the mandible: in vitro comparative study

Peixoto, Raniel Fernandes 28 June 2017 (has links)
Nos casos de perda óssea vertical severa, principalmente em áreas posteriores da mandíbula, uma alternativa às cirurgias de enxerto ósseo, pouco empregada e estudada, é a utilização de prótese parcial fixa (PPF) com cantilever distal. Pensando no material de infraestrutura que garanta resistência adequada para suportar as forças mastigatórias em longo prazo, aliado ao desenvolvimento da zircônia (Zr) e da tecnologia CAD/CAM, o objetivo deste estudo foi avaliar o desajuste vertical, perda de torque, resistência à fratura do cantilever e distribuição de tensões em PPFs parafusadas sobre implantes do tipo cone morse, confeccionadas em diferentes materiais de infraestrutura (Co-Cr [Fundição Convencional] e Co-Cr e Zr [CAD/CAM]) e posicionadas na área correspondente à região posterior da mandíbula. Foram confeccionadas 40 PPFs com cantilever distal e distribuídas em 5 grupos (n=8), de acordo com o material da infraestrutura: 1 Co-Cr (Fundição convencional soldagem a laser); 2 Co-Cr (Fundição convencional soldagem TIG); 3 Co-Cr (Fundição convencional monobloco); 4 Co-Cr (CAD/CAM) e 5 Zr (CAD/CAM). A análise do desajuste vertical foi realizada em 4 momentos distintos, com auxílio de estereomicroscopia (aumento de 50×) e usando o método de Sheffiled: T0 Infraestrutura no modelo mestre; T1 Infraestrutura no modelo de poliuretano, antes da aplicação do revestimento cerâmico; T2 PPF após aplicação do revestimento cerâmico e antes da ciclagem termomecânica e T3 PPF após da ciclagem termomecânica. A avaliação do afrouxamento de parafusos foi realizada antes (T2) e após (T3) a ciclagem termomecânica e foi obtida com o auxílio de um torquímetro digital com precisão de 0,1 N.cm. Para a realização da ciclagem termomecânica as PPFs foram posicionadas na máquina de ensaio e uma carga de 120 N foi aplicada sobre elas, buscando simular 14 meses de utilização (1.200.000 ciclos). A resistência máxima à fratura do cantilever foi determinada por meio do ensaio de flexão e, para isso, uma carga perpendicular ao longo eixo da peça protética foi aplicada, com uma velocidade de aproximação de 0,5 mm/min. Uma nova PPF para cada grupo foi confeccionada para ser utilizada na avaliação da distribuição de tensões quando elas foram submetidas a carregamento puntiforme no cantilever e oclusal distribuído (150 N), por meio de análise fotoelástica. Em geral, PPFs com infraestruturas em monobloco (G3) apresentaram maiores desajustes verticais, especialmente no elemento solto da segunda e terceira condição experimental e foram associados com maior concentração de tensões, tanto no carregamento puntiforme (360,07 kPa) quanto oclusal distruído (302,46 kPa). Por outro lado, infraestruturas obtidas por meio do sistema CAD/CAM mostraram os menores desajustes verticais, se assemelhando estatisticamente (p>0,05), em vários momentos, com infraestruturas soldadas e melhores distribuições de tensões, atingindo valores inferiores a 280 kPa no carregamento puntiforme e a 200 kPa no oclusal distribuído. A moldagem de transferência (T0 &rarr; T1) e a ciclagem termomecânica (T2 &rarr; T3) pouco influenciaram no desajuste vertical dos grupos. Já o processo de aplicação do revestimento cerâmico (T1 &rarr; T2) e o seu efeito cumulativo com a ciclagem termomecânica (T1 &rarr; &rarr; T3) foram responsáveis por alterações consideráveis no desajuste vertical dos grupos, sobretudo naqueles fundidos convencionalmente (G1, G2 e G3). A ciclagem termomecânica teve um efeito considerável no percentual de perda de torque intragrupo (pMolar=0,039; pPré-molar=0,044), embora comparações entre os diferentes grupos não tenham demonstrado significância estatística (pMolar=0,116; pPré-molar=0,334). PPFs com infraestrutura metálica (>410,83±72,26 N) apresentaram resistência à fratura consideravelmente maior (p<0,05) do que a zirconia (277,47±39,10 N) e os primeiros sinais de fratura do revestimento cerâmico foram observados em torno de 900 N. Dentro das limitações deste estudo, PPFs com infraestruturas confeccionadas por meio do sistema CAD/CAM foram associadas com melhor adaptação cervical e distribuição de tensões, embora a secção das infraestruturas seguida de soldagem pode também ser uma alternativa viável, com base na proximidade dos valores de desajustes verticais e distribuição de tensão. Adicionalmente, PPFs com infraestruturas em zircônia podem ser usadas com certo grau de segurança, tendo em vista a boa adaptação marginal e distribuição de tensões, bem como altos valores de resistência à fratura constatados. / In cases of severe vertical bone loss, especially in posterior region of the mandible, an alternative to bone graft surgery, little used and studied, is the use of implant-supported cantilever fixed partial denture (FPD). Thinking about the framework material that ensures adequate strength to resist the masticatory loads in long term, together with the development of zirconia (Zr) and of CAD/CAM technology, the aim of this study is to evaluate the vertical misfit, torque loss and fracture resistance of cantilever and stress distribution in FPDs screwretained on Morse taper implants, fabricated with different framework materials (Co-Cr [Conventional Casting] and Co-Cr and Zr [CAD/CAM]) and positioned on the posterior region of the mandible. Forty FPDs with distal cantilever were fabricated and distributed into 5 groups (n=8), according to framework material: 1 Co-Cr (Conventional casting laser welding); 2 Co-Cr (Conventional casting TIG welding); 3 Co-Cr (Conventional casting one-piece); 4 Co-Cr (CAD/CAM) and 5 Zr (CAD/CAM). Analysis of vertical misfit was performed in 4 different moments, using stereomicroscopy (50× magnification) and the Sheffield method: T0 Framework on master model; T1 Framework on polyurethane model, before the ceramic veneering application; T2 FPD after application of the ceramic veneering and before the thermomechanical cycling and T3 FPD after thermomechanical cycling. Evaluation of screw loosening was performed before (T2) and after (T3) thermomechanical cycling and was obtained by a digital torque wrench with an accuracy of 0.1 N.cm. To perform the thermomechanical cycling, FPDs were positioned in the testing machine, and a 120 N load was applied on them, seeking to simulate 14 months of use (1,200,000 cycles). Fracture maximum resistance of the cantilever was determined by the flexural test and, therefore, a perpendicular force on the cantilever was applied at a crosshead speed of 0.5 mm/min. A new FDP for each group was fabricated to be used in the evaluation of the stress distribution, when they were submitted to punctiform on the cantilever and oclusal distributed loads (150 N), by the photoelastic analysis. In general, FPDs with one-piece frameworks (G3) presented higher vertical misfits, especially in the element not tightened of the second and third experimental conditions, and were associated with higher stress concentration in both the punctiform (360.07 kPa) and oclusal distributed (302.46 kPa) loads. On the other hand, the frameworks obtained by the CAD/CAM system showed the smaller vertical misfits, being statistically similar (p>0.05) to welded frameworks at various times, and better stress distributions, reaching values less than 280 kPa in the punctiform load and 200 kPa in the occlusal distributed load. Transfer impression (T0 &rarr; T1) and thermomechanical cycling (T2 &rarr; T3) had little effect on vertical misfit of the groups. The application process of the ceramic veneering (T1 &rarr; T2) and its cumulative effect with thermomechanical cycling (T1 &rarr;T3) were responsible for considerable changes in vertical misfit of the group, especially in those conventionally cast (G1, G2 and G3). A thermomechanical cycling had considerable effect in the percentage of intragroup torque loss (pMolar=0.039; pPré-molar=0.044), although comparisons between the different groups did not show statistical significance (pMolar=0.116; pPrémolar= 0.334). FPDs with metal frameworks (>410.83±72.26 N) showed considerably higher fracture resistance (p<0.05) than zirconia (277.47±39.10 N) and the first signs of fracture of the ceramic veneering were observed around 900 N. Within the limitations of this study, FPDs with frameworks fabricated using the CAD/CAM system were associated with better cervical adaptation and stress distribution, although the section of the frameworks followed by welding may also be a viable alternative, based on the proximity of the values of vertical misfits and stress distribution. Additionally, FPDs with zirconia frameworks can be used with some degree of security, considering the good marginal adaptation and stress distribution, as well as high values of fracture resistance verified.
14

Avaliação biomecânica de prótese parcial fixa com cantilever sobre implantes em região posterior da mandíbula: estudo comparativo in vitro / Biomechanical evaluation of implant-supported cantilever fixed partial denture in posterior region of the mandible: in vitro comparative study

Raniel Fernandes Peixoto 28 June 2017 (has links)
Nos casos de perda óssea vertical severa, principalmente em áreas posteriores da mandíbula, uma alternativa às cirurgias de enxerto ósseo, pouco empregada e estudada, é a utilização de prótese parcial fixa (PPF) com cantilever distal. Pensando no material de infraestrutura que garanta resistência adequada para suportar as forças mastigatórias em longo prazo, aliado ao desenvolvimento da zircônia (Zr) e da tecnologia CAD/CAM, o objetivo deste estudo foi avaliar o desajuste vertical, perda de torque, resistência à fratura do cantilever e distribuição de tensões em PPFs parafusadas sobre implantes do tipo cone morse, confeccionadas em diferentes materiais de infraestrutura (Co-Cr [Fundição Convencional] e Co-Cr e Zr [CAD/CAM]) e posicionadas na área correspondente à região posterior da mandíbula. Foram confeccionadas 40 PPFs com cantilever distal e distribuídas em 5 grupos (n=8), de acordo com o material da infraestrutura: 1 Co-Cr (Fundição convencional soldagem a laser); 2 Co-Cr (Fundição convencional soldagem TIG); 3 Co-Cr (Fundição convencional monobloco); 4 Co-Cr (CAD/CAM) e 5 Zr (CAD/CAM). A análise do desajuste vertical foi realizada em 4 momentos distintos, com auxílio de estereomicroscopia (aumento de 50×) e usando o método de Sheffiled: T0 Infraestrutura no modelo mestre; T1 Infraestrutura no modelo de poliuretano, antes da aplicação do revestimento cerâmico; T2 PPF após aplicação do revestimento cerâmico e antes da ciclagem termomecânica e T3 PPF após da ciclagem termomecânica. A avaliação do afrouxamento de parafusos foi realizada antes (T2) e após (T3) a ciclagem termomecânica e foi obtida com o auxílio de um torquímetro digital com precisão de 0,1 N.cm. Para a realização da ciclagem termomecânica as PPFs foram posicionadas na máquina de ensaio e uma carga de 120 N foi aplicada sobre elas, buscando simular 14 meses de utilização (1.200.000 ciclos). A resistência máxima à fratura do cantilever foi determinada por meio do ensaio de flexão e, para isso, uma carga perpendicular ao longo eixo da peça protética foi aplicada, com uma velocidade de aproximação de 0,5 mm/min. Uma nova PPF para cada grupo foi confeccionada para ser utilizada na avaliação da distribuição de tensões quando elas foram submetidas a carregamento puntiforme no cantilever e oclusal distribuído (150 N), por meio de análise fotoelástica. Em geral, PPFs com infraestruturas em monobloco (G3) apresentaram maiores desajustes verticais, especialmente no elemento solto da segunda e terceira condição experimental e foram associados com maior concentração de tensões, tanto no carregamento puntiforme (360,07 kPa) quanto oclusal distruído (302,46 kPa). Por outro lado, infraestruturas obtidas por meio do sistema CAD/CAM mostraram os menores desajustes verticais, se assemelhando estatisticamente (p>0,05), em vários momentos, com infraestruturas soldadas e melhores distribuições de tensões, atingindo valores inferiores a 280 kPa no carregamento puntiforme e a 200 kPa no oclusal distribuído. A moldagem de transferência (T0 &rarr; T1) e a ciclagem termomecânica (T2 &rarr; T3) pouco influenciaram no desajuste vertical dos grupos. Já o processo de aplicação do revestimento cerâmico (T1 &rarr; T2) e o seu efeito cumulativo com a ciclagem termomecânica (T1 &rarr; &rarr; T3) foram responsáveis por alterações consideráveis no desajuste vertical dos grupos, sobretudo naqueles fundidos convencionalmente (G1, G2 e G3). A ciclagem termomecânica teve um efeito considerável no percentual de perda de torque intragrupo (pMolar=0,039; pPré-molar=0,044), embora comparações entre os diferentes grupos não tenham demonstrado significância estatística (pMolar=0,116; pPré-molar=0,334). PPFs com infraestrutura metálica (>410,83±72,26 N) apresentaram resistência à fratura consideravelmente maior (p<0,05) do que a zirconia (277,47±39,10 N) e os primeiros sinais de fratura do revestimento cerâmico foram observados em torno de 900 N. Dentro das limitações deste estudo, PPFs com infraestruturas confeccionadas por meio do sistema CAD/CAM foram associadas com melhor adaptação cervical e distribuição de tensões, embora a secção das infraestruturas seguida de soldagem pode também ser uma alternativa viável, com base na proximidade dos valores de desajustes verticais e distribuição de tensão. Adicionalmente, PPFs com infraestruturas em zircônia podem ser usadas com certo grau de segurança, tendo em vista a boa adaptação marginal e distribuição de tensões, bem como altos valores de resistência à fratura constatados. / In cases of severe vertical bone loss, especially in posterior region of the mandible, an alternative to bone graft surgery, little used and studied, is the use of implant-supported cantilever fixed partial denture (FPD). Thinking about the framework material that ensures adequate strength to resist the masticatory loads in long term, together with the development of zirconia (Zr) and of CAD/CAM technology, the aim of this study is to evaluate the vertical misfit, torque loss and fracture resistance of cantilever and stress distribution in FPDs screwretained on Morse taper implants, fabricated with different framework materials (Co-Cr [Conventional Casting] and Co-Cr and Zr [CAD/CAM]) and positioned on the posterior region of the mandible. Forty FPDs with distal cantilever were fabricated and distributed into 5 groups (n=8), according to framework material: 1 Co-Cr (Conventional casting laser welding); 2 Co-Cr (Conventional casting TIG welding); 3 Co-Cr (Conventional casting one-piece); 4 Co-Cr (CAD/CAM) and 5 Zr (CAD/CAM). Analysis of vertical misfit was performed in 4 different moments, using stereomicroscopy (50× magnification) and the Sheffield method: T0 Framework on master model; T1 Framework on polyurethane model, before the ceramic veneering application; T2 FPD after application of the ceramic veneering and before the thermomechanical cycling and T3 FPD after thermomechanical cycling. Evaluation of screw loosening was performed before (T2) and after (T3) thermomechanical cycling and was obtained by a digital torque wrench with an accuracy of 0.1 N.cm. To perform the thermomechanical cycling, FPDs were positioned in the testing machine, and a 120 N load was applied on them, seeking to simulate 14 months of use (1,200,000 cycles). Fracture maximum resistance of the cantilever was determined by the flexural test and, therefore, a perpendicular force on the cantilever was applied at a crosshead speed of 0.5 mm/min. A new FDP for each group was fabricated to be used in the evaluation of the stress distribution, when they were submitted to punctiform on the cantilever and oclusal distributed loads (150 N), by the photoelastic analysis. In general, FPDs with one-piece frameworks (G3) presented higher vertical misfits, especially in the element not tightened of the second and third experimental conditions, and were associated with higher stress concentration in both the punctiform (360.07 kPa) and oclusal distributed (302.46 kPa) loads. On the other hand, the frameworks obtained by the CAD/CAM system showed the smaller vertical misfits, being statistically similar (p>0.05) to welded frameworks at various times, and better stress distributions, reaching values less than 280 kPa in the punctiform load and 200 kPa in the occlusal distributed load. Transfer impression (T0 &rarr; T1) and thermomechanical cycling (T2 &rarr; T3) had little effect on vertical misfit of the groups. The application process of the ceramic veneering (T1 &rarr; T2) and its cumulative effect with thermomechanical cycling (T1 &rarr;T3) were responsible for considerable changes in vertical misfit of the group, especially in those conventionally cast (G1, G2 and G3). A thermomechanical cycling had considerable effect in the percentage of intragroup torque loss (pMolar=0.039; pPré-molar=0.044), although comparisons between the different groups did not show statistical significance (pMolar=0.116; pPrémolar= 0.334). FPDs with metal frameworks (>410.83±72.26 N) showed considerably higher fracture resistance (p<0.05) than zirconia (277.47±39.10 N) and the first signs of fracture of the ceramic veneering were observed around 900 N. Within the limitations of this study, FPDs with frameworks fabricated using the CAD/CAM system were associated with better cervical adaptation and stress distribution, although the section of the frameworks followed by welding may also be a viable alternative, based on the proximity of the values of vertical misfits and stress distribution. Additionally, FPDs with zirconia frameworks can be used with some degree of security, considering the good marginal adaptation and stress distribution, as well as high values of fracture resistance verified.
15

Resistência mecânica e desajuste marginal do titânio comercialmente puro submetido a dois métodos de soldagem: TIG e Laser / Mechanic resistance and marginal misfit of pure Ti submitted to two welding methods TIG and Laser

Atoui, Juliana Abdallah 05 December 2008 (has links)
O objetivo deste trabalho foi avaliar o efeito da soldagem TIG (\"tungsten inert gas\") e compará-la com soldagem a laser, em hastes cilíndricas e supra-estruturas implantosuportadas, confeccionadas em titânio comercialmente puro (Ti cp) por meio dos ensaios de resistência mecânica (tração e flexão) e desajuste marginal, respectivamente. Foram confeccionados noventa corpos-de-prova em titânio cp, sendo sessenta, na forma de hastes cilíndricas, obtidas por fundição de hastes de latão, e trinta na forma de supra-estruturas implanto-suportadas, obtidas por modelo de gesso com quatro análogos de implantes Microunit (Conexão), com dez repetições para cada grupo (controle, solda TIG, solda a Laser). Para a obtenção dos corpos-de-prova, foi realizada inclusão em revestimento Rematitan Plus, de acordo com as instruções fabricante. Os anéis foram submetidos aos ciclos térmicos e posicionados na máquina de fundição (Rematitan), sob arco voltaico, vácuo e atmosfera de argônio, com injeção de titânio sob vácuo-pressão. Após resfriamento, as fundições foram desincluídas e jateadas com óxido de alumínio. Os corpos-de-prova obtidos em forma de hastes cilíndricas foram distribuídos aleatoriamente, em três grupos, para ambos os ensaios, resistência à tração e flexão: grupo controle (sem solda), solda TIG e solda a Laser. As trinta supra-estruturas foram divididas aleatoriamente em três grupos: I- controle - monobloco; II-B- pós-soldagem TIG e III-B- pós-soldagem a Laser; os grupos II-A e III-A, foram constituídos dos espécimes antes do processo de soldagem: II-A- pré-soldagem TIG e III-A- pré-soldagem a Laser. Os dados obtidos para o Ensaio de Tração (MPa) foram analisados estatisticamente pelos testes ANOVA e Tukey (&alpha;= 0,05). O teste complementar de Tukey (p = 0,05) evidenciou que houve diferença entre o grupo controle (605,84 ± 19,83) e os métodos de soldagem TIG (514,90 ± 37,76) e Laser (515,85 ± 62,07). Para o Ensaio de Flexão (MPa), o teste não-paramétrico de Kruskal-Wallis mostrou que não houve diferença estatisticamente significante entre os processos de soldagem TIG (1559,66) e Laser (1621,64), contudo a diferença foi significante entre estes grupos e o controle (1908,75). Para análise dos resultados do desajuste marginal (&mu;m) das supra-estruturas implanto-suportadas, o teste nãoparamétrico de Kruskal-Wallis revelou que não houve diferença estatisticamente significante entre os grupos pós-soldagem TIG (250) e pós-soldagem Laser (241), entretanto, o grupo controle (770) apresentou o maior desajuste. Pelos resultados obtidos e dentro das limitações deste estudo, pode-se afirmar que a soldagem a TIG propicia a obtenção de resultados similares à soldagem a Laser. / The aim of this study was to evaluate the effect of TIG welding (tungsten inert gas) and compare it with Laser welding, of the cylindrical rods and implant-supported frameworks, obtained by in commercially pure titanium (cp) through the mechanical resistance (tensile and flexural strength) and misfit marginal, respectively. Ninety specimens have been fabricated titanium cp, and sixty, cylindrical rods, obtained by casting of the brass rods, and thirty implant-supported frameworks, obtained by plaster die with four similar - Microunit implants (Connection), with ten repetitions for each group (control, TIG welding, laser welding). The specimens were invested in Rematitan Plus, according to the manufacturer instructions. The rings were subjected to thermal cycling and positioned in the machine of casting (Rematitan) under voltaic arc, vacuum and atmosphere of argon, with injection of titanium vacuumpressure. After cooling, were manually and airbone-particle abraded with aluminum oxide. The specimes cylindrical rods were randomly distributed in three groups, for tests, tensile and flexural strength: the control group (without welding), TIG welding and soldering laser. The above thirty-structures were randomly divided into three groups: I- one-piece-cast (control)-, II-B-after-TIG welding and III-B-after-Laser welding, the Group II-A, III-A, consisted of specimens before the process of welding: II-A-before-TIG welding and III-A before-Laser welding. The results for the test Traction were submitted to variance analysis ANOVA (p < 0.05) being observed difference between groups. The supplementary Tukey test (p = 0.05) showed that there was a difference between the control group (605.84 ± 19.83) and the methods of welding TIG (514.90 ± 37.76) and laser (515.85 ± 62.07). To test the Flexion nonparametric test Kruskal-Wallis showed that there was no statistically significant difference between the processes of TIG welding (1559.66) and Laser (1621.64), but the difference was significant between these groups and control (1908.75). For analysis of the results of marginal misfit implant-supported frameworks, the non-parametric Kruskal-Wallis test revealed that there was no statistically significant difference between groups after-TIG welding (250) and after- Laser welding (241), however, the control group (770) showed the largest misfit. With these and the limitations of this study TIG welding in may be to Laser welding.
16

Resistência mecânica e desajuste marginal do titânio comercialmente puro submetido a dois métodos de soldagem: TIG e Laser / Mechanic resistance and marginal misfit of pure Ti submitted to two welding methods TIG and Laser

Juliana Abdallah Atoui 05 December 2008 (has links)
O objetivo deste trabalho foi avaliar o efeito da soldagem TIG (\"tungsten inert gas\") e compará-la com soldagem a laser, em hastes cilíndricas e supra-estruturas implantosuportadas, confeccionadas em titânio comercialmente puro (Ti cp) por meio dos ensaios de resistência mecânica (tração e flexão) e desajuste marginal, respectivamente. Foram confeccionados noventa corpos-de-prova em titânio cp, sendo sessenta, na forma de hastes cilíndricas, obtidas por fundição de hastes de latão, e trinta na forma de supra-estruturas implanto-suportadas, obtidas por modelo de gesso com quatro análogos de implantes Microunit (Conexão), com dez repetições para cada grupo (controle, solda TIG, solda a Laser). Para a obtenção dos corpos-de-prova, foi realizada inclusão em revestimento Rematitan Plus, de acordo com as instruções fabricante. Os anéis foram submetidos aos ciclos térmicos e posicionados na máquina de fundição (Rematitan), sob arco voltaico, vácuo e atmosfera de argônio, com injeção de titânio sob vácuo-pressão. Após resfriamento, as fundições foram desincluídas e jateadas com óxido de alumínio. Os corpos-de-prova obtidos em forma de hastes cilíndricas foram distribuídos aleatoriamente, em três grupos, para ambos os ensaios, resistência à tração e flexão: grupo controle (sem solda), solda TIG e solda a Laser. As trinta supra-estruturas foram divididas aleatoriamente em três grupos: I- controle - monobloco; II-B- pós-soldagem TIG e III-B- pós-soldagem a Laser; os grupos II-A e III-A, foram constituídos dos espécimes antes do processo de soldagem: II-A- pré-soldagem TIG e III-A- pré-soldagem a Laser. Os dados obtidos para o Ensaio de Tração (MPa) foram analisados estatisticamente pelos testes ANOVA e Tukey (&alpha;= 0,05). O teste complementar de Tukey (p = 0,05) evidenciou que houve diferença entre o grupo controle (605,84 ± 19,83) e os métodos de soldagem TIG (514,90 ± 37,76) e Laser (515,85 ± 62,07). Para o Ensaio de Flexão (MPa), o teste não-paramétrico de Kruskal-Wallis mostrou que não houve diferença estatisticamente significante entre os processos de soldagem TIG (1559,66) e Laser (1621,64), contudo a diferença foi significante entre estes grupos e o controle (1908,75). Para análise dos resultados do desajuste marginal (&mu;m) das supra-estruturas implanto-suportadas, o teste nãoparamétrico de Kruskal-Wallis revelou que não houve diferença estatisticamente significante entre os grupos pós-soldagem TIG (250) e pós-soldagem Laser (241), entretanto, o grupo controle (770) apresentou o maior desajuste. Pelos resultados obtidos e dentro das limitações deste estudo, pode-se afirmar que a soldagem a TIG propicia a obtenção de resultados similares à soldagem a Laser. / The aim of this study was to evaluate the effect of TIG welding (tungsten inert gas) and compare it with Laser welding, of the cylindrical rods and implant-supported frameworks, obtained by in commercially pure titanium (cp) through the mechanical resistance (tensile and flexural strength) and misfit marginal, respectively. Ninety specimens have been fabricated titanium cp, and sixty, cylindrical rods, obtained by casting of the brass rods, and thirty implant-supported frameworks, obtained by plaster die with four similar - Microunit implants (Connection), with ten repetitions for each group (control, TIG welding, laser welding). The specimens were invested in Rematitan Plus, according to the manufacturer instructions. The rings were subjected to thermal cycling and positioned in the machine of casting (Rematitan) under voltaic arc, vacuum and atmosphere of argon, with injection of titanium vacuumpressure. After cooling, were manually and airbone-particle abraded with aluminum oxide. The specimes cylindrical rods were randomly distributed in three groups, for tests, tensile and flexural strength: the control group (without welding), TIG welding and soldering laser. The above thirty-structures were randomly divided into three groups: I- one-piece-cast (control)-, II-B-after-TIG welding and III-B-after-Laser welding, the Group II-A, III-A, consisted of specimens before the process of welding: II-A-before-TIG welding and III-A before-Laser welding. The results for the test Traction were submitted to variance analysis ANOVA (p < 0.05) being observed difference between groups. The supplementary Tukey test (p = 0.05) showed that there was a difference between the control group (605.84 ± 19.83) and the methods of welding TIG (514.90 ± 37.76) and laser (515.85 ± 62.07). To test the Flexion nonparametric test Kruskal-Wallis showed that there was no statistically significant difference between the processes of TIG welding (1559.66) and Laser (1621.64), but the difference was significant between these groups and control (1908.75). For analysis of the results of marginal misfit implant-supported frameworks, the non-parametric Kruskal-Wallis test revealed that there was no statistically significant difference between groups after-TIG welding (250) and after- Laser welding (241), however, the control group (770) showed the largest misfit. With these and the limitations of this study TIG welding in may be to Laser welding.
17

Duas representações de família : "Os Glass", de J. D. Salinger, e "Os Tenenbaum", de Wes Anderson & Owen Wilson

Rollo, André Corrêa January 2006 (has links)
O presente trabalho analisa o tema das famílias desajustadas no sistema ficcional norte-americano. Os corpora estudados são os contos sobre a família Glass, de J. D. Salinger, e o roteiro do filme The Royal Tenenbaums, escrito por Wes Anderson e Owen Wilson. O enfoque comparatista aqui desenvolvido é duplo: de um lado, o diálogo temático entre a obra dos diferentes autores, de outro lado, a investigação sobre os modos em que os contos de Salinger e o filme dialogam com as demais artes. Desta forma, a leitura crítica aqui efetuada rastreia as estratégias intertextuais e inter-artísticas presentes nos corpora. A análise temática é desenvolvida a partir da definição de um conceito de desajuste. A inadaptação pode ser vista como uma inadequação ou reação do indivíduo ao grupo ou comunidade a que pertence, aos pensamentos, valores e modos de agir desta. Tanto os Glass quanto os Tenenbaums são irmãos que, quando crianças, foram destacadamente brilhantes em atividades comumente desempenhadas por adultos. Ao amadurecer tornaram-se pessoas problemáticas com dificuldades de relacionamento pessoal. Para chegar à síntese da leitura comparativa visualizamos três elementos comuns em ambos os corpora: o conflito do indivíduo com o mundo; a dificuldade da comunicação pessoal (além de discorrermos sobre as estratégias da comunicação ficcional) e a dificuldade em lidar com a instabilidade. Ao final, examino como tais problemas são superados pelos personagens. Além disso, também tentamos descrever como tais obras inserem-se na tradição ficcional norte-americana de produção obras cujo tema principal são as problemáticas relações familiares. / The present work analyses the theme of maladjusted families in the American fictional system. The corpora consists of the short stories about the Glass family, by J. D. Salinger, and the screenplay for The Royal Tenenbaums, written by Wes Anderson and Owen Wilson. The comparative approach here developed is twofold: on the one hand, a thematic dialogue between the different authors' works, on the other hand, a research about the ways in which Salinger's stories and the film dialogue with another arts. Thus, the critical reading searches the intertextual and interartistic strategies present in the corpora. The thematic analysis is developed from a definition of a concept of maladjustment. Maladjustment can be seen as an individual's inadequacy or reaction to the group or community to which he/she belongs, to the thoughts, to the values and ways of behaviour. Both Glass and Tenenbaums are siblings which, when children, were outstandingly brilliant in activities mainly fullfilled by adults. Coming of age they become problematical with difficulties in personal relationship. To summarize the comparative reading we highlight three elements in common to both corpora: the individual's conflict with the world; the difficult of the personal communication (besides the strategies of fictional communication) and the difficulty in deal with instability. Finally, I examine how such problems are overcome by the characters. Besides this, I also try to describe how such works are inserted in the American fictional tradition of producing works whose main theme is the problematic family relationship.
18

Duas representações de família : "Os Glass", de J. D. Salinger, e "Os Tenenbaum", de Wes Anderson & Owen Wilson

Rollo, André Corrêa January 2006 (has links)
O presente trabalho analisa o tema das famílias desajustadas no sistema ficcional norte-americano. Os corpora estudados são os contos sobre a família Glass, de J. D. Salinger, e o roteiro do filme The Royal Tenenbaums, escrito por Wes Anderson e Owen Wilson. O enfoque comparatista aqui desenvolvido é duplo: de um lado, o diálogo temático entre a obra dos diferentes autores, de outro lado, a investigação sobre os modos em que os contos de Salinger e o filme dialogam com as demais artes. Desta forma, a leitura crítica aqui efetuada rastreia as estratégias intertextuais e inter-artísticas presentes nos corpora. A análise temática é desenvolvida a partir da definição de um conceito de desajuste. A inadaptação pode ser vista como uma inadequação ou reação do indivíduo ao grupo ou comunidade a que pertence, aos pensamentos, valores e modos de agir desta. Tanto os Glass quanto os Tenenbaums são irmãos que, quando crianças, foram destacadamente brilhantes em atividades comumente desempenhadas por adultos. Ao amadurecer tornaram-se pessoas problemáticas com dificuldades de relacionamento pessoal. Para chegar à síntese da leitura comparativa visualizamos três elementos comuns em ambos os corpora: o conflito do indivíduo com o mundo; a dificuldade da comunicação pessoal (além de discorrermos sobre as estratégias da comunicação ficcional) e a dificuldade em lidar com a instabilidade. Ao final, examino como tais problemas são superados pelos personagens. Além disso, também tentamos descrever como tais obras inserem-se na tradição ficcional norte-americana de produção obras cujo tema principal são as problemáticas relações familiares. / The present work analyses the theme of maladjusted families in the American fictional system. The corpora consists of the short stories about the Glass family, by J. D. Salinger, and the screenplay for The Royal Tenenbaums, written by Wes Anderson and Owen Wilson. The comparative approach here developed is twofold: on the one hand, a thematic dialogue between the different authors' works, on the other hand, a research about the ways in which Salinger's stories and the film dialogue with another arts. Thus, the critical reading searches the intertextual and interartistic strategies present in the corpora. The thematic analysis is developed from a definition of a concept of maladjustment. Maladjustment can be seen as an individual's inadequacy or reaction to the group or community to which he/she belongs, to the thoughts, to the values and ways of behaviour. Both Glass and Tenenbaums are siblings which, when children, were outstandingly brilliant in activities mainly fullfilled by adults. Coming of age they become problematical with difficulties in personal relationship. To summarize the comparative reading we highlight three elements in common to both corpora: the individual's conflict with the world; the difficult of the personal communication (besides the strategies of fictional communication) and the difficulty in deal with instability. Finally, I examine how such problems are overcome by the characters. Besides this, I also try to describe how such works are inserted in the American fictional tradition of producing works whose main theme is the problematic family relationship.
19

Duas representações de família : "Os Glass", de J. D. Salinger, e "Os Tenenbaum", de Wes Anderson & Owen Wilson

Rollo, André Corrêa January 2006 (has links)
O presente trabalho analisa o tema das famílias desajustadas no sistema ficcional norte-americano. Os corpora estudados são os contos sobre a família Glass, de J. D. Salinger, e o roteiro do filme The Royal Tenenbaums, escrito por Wes Anderson e Owen Wilson. O enfoque comparatista aqui desenvolvido é duplo: de um lado, o diálogo temático entre a obra dos diferentes autores, de outro lado, a investigação sobre os modos em que os contos de Salinger e o filme dialogam com as demais artes. Desta forma, a leitura crítica aqui efetuada rastreia as estratégias intertextuais e inter-artísticas presentes nos corpora. A análise temática é desenvolvida a partir da definição de um conceito de desajuste. A inadaptação pode ser vista como uma inadequação ou reação do indivíduo ao grupo ou comunidade a que pertence, aos pensamentos, valores e modos de agir desta. Tanto os Glass quanto os Tenenbaums são irmãos que, quando crianças, foram destacadamente brilhantes em atividades comumente desempenhadas por adultos. Ao amadurecer tornaram-se pessoas problemáticas com dificuldades de relacionamento pessoal. Para chegar à síntese da leitura comparativa visualizamos três elementos comuns em ambos os corpora: o conflito do indivíduo com o mundo; a dificuldade da comunicação pessoal (além de discorrermos sobre as estratégias da comunicação ficcional) e a dificuldade em lidar com a instabilidade. Ao final, examino como tais problemas são superados pelos personagens. Além disso, também tentamos descrever como tais obras inserem-se na tradição ficcional norte-americana de produção obras cujo tema principal são as problemáticas relações familiares. / The present work analyses the theme of maladjusted families in the American fictional system. The corpora consists of the short stories about the Glass family, by J. D. Salinger, and the screenplay for The Royal Tenenbaums, written by Wes Anderson and Owen Wilson. The comparative approach here developed is twofold: on the one hand, a thematic dialogue between the different authors' works, on the other hand, a research about the ways in which Salinger's stories and the film dialogue with another arts. Thus, the critical reading searches the intertextual and interartistic strategies present in the corpora. The thematic analysis is developed from a definition of a concept of maladjustment. Maladjustment can be seen as an individual's inadequacy or reaction to the group or community to which he/she belongs, to the thoughts, to the values and ways of behaviour. Both Glass and Tenenbaums are siblings which, when children, were outstandingly brilliant in activities mainly fullfilled by adults. Coming of age they become problematical with difficulties in personal relationship. To summarize the comparative reading we highlight three elements in common to both corpora: the individual's conflict with the world; the difficult of the personal communication (besides the strategies of fictional communication) and the difficulty in deal with instability. Finally, I examine how such problems are overcome by the characters. Besides this, I also try to describe how such works are inserted in the American fictional tradition of producing works whose main theme is the problematic family relationship.

Page generated in 0.0846 seconds