• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 116
  • Tagged with
  • 116
  • 116
  • 76
  • 75
  • 38
  • 37
  • 25
  • 24
  • 23
  • 23
  • 22
  • 22
  • 21
  • 18
  • 18
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Desempenho térmico de habitações do PMCMV em paredes de concreto : estudo de caso em São Carlos-SP e diretrizes de projeto para a Zona Bioclimática 4 / Thermal sensation in low-income brazilian houses built in concrete walls

Simone Mesquita Alvares 13 June 2018 (has links)
O atual programa de contenção do déficit habitacional brasileiro, Minha Casa Minha Vida, criado em 2009, apesar de numericamente significativo, apresenta uma série de complicações e inadequações. Um importante exemplo é a inadequação das construções à Zona Bioclimática na qual o projeto é construído. Diante desse fato, o conforto térmico do usuário deixa a desejar pois os ambientes são desconfortáveis e nada sustentáveis do ponto de vista ambiental. Neste contexto, o trabalho teve como objetivo avaliar o desempenho térmico de habitações de interesse social do PMCMV na Zona Bioclimática 4 construídas com paredes de concreto armado moldadas no local, técnica de rápida execução que vem sendo utilizada em larga escala no país; complementarmente, foi analisada a percepção do usuário frente às condições de conforto térmico em um desses residenciais. A avaliação do desempenho térmico das habitações foi feita com base nos regulamentos nacionais NBR 15220 e NBR 15575 em seus procedimentos simplificados; para avaliar a ventilação, via método de visualização de escoamento (mesa dágua) e a insolação, via simulação computacional de horas de sombreamento com auxílio de cartas solares; para a avaliação da percepção do usuário frente ao conforto térmico, foram feitas pesquisas de campo em um dos empreendimentos de habitações sociais na zona em estudo tendo como base os questionários ASHRAE 55 juntamente com coleta de dados climáticos de temperatura e umidade relativa e com levantamento de modificações projetuais. A partir dos dados coletados, pôde-se confirmar objetivamente a inadequação aos limites mínimos estabelecidos pelas normas de desempenho térmico nos parâmetros de vedação vertical e cobertura. Em entrevista com os moradores, as casas foram consideradas desconfortáveis termicamente no inverno e verão. A partir do diagnóstico das alterações nos projetos, nota-se que a maior parte das casas sofrem alterações para maior adequação à vida dos moradores, essas que se tornam responsáveis pelo desconforto térmico. Fica evidente a necessidade do aumento da inércia térmica do sistema construtivo, para futuras casas construídas com o referido sistema além da necessidade de um plano de expansão da moradia que oriente o morador a fazer modificações que não prejudiquem o desempenho térmico do edifício e o conforto térmico dos habitantes. / The current Brazilian low-income housing program, named Minha Casa Minha Vida, was created in 2009 by the Brazilian government and despite being numerically significant, it has many significant issues that affect its quality. One important example is the used construction methods that do not take into account the climate or the bioclimatic zones where the houses are located resulting in energy efficiency, environmental and thermal confirm issues. This work is developed in this context and aims to evaluate the objective and subjective thermal performance of the houses built in the Zone 4 with reinforced concrete walls molded in place, which is a widespread construction technique within the studied program. Thermal performance of the dwellings was analyzed in the light of the Brazilian regulation norm NBR15220 and NBR 15575. Surveys based on ASHRAE 55 norm were conducted to evaluate the user\'s thermal comfort perception and in situ measurements were taken at the studied bioclimatic zone. From the data collected, we conclude that the houses do not meet the norm limits and that they are also subjectively uncomfortable, during summer and winter. As means to increase comfort, we note that all houses dwellers modified their houses making it clear that future houses should have more thermal inertia and that, as the program expands, dwellers should be instructed to not make construction changes that might affect their thermal comfort.
72

AVALIAÇÃO DO CONFORTO TÉRMICO DE UM APRISCO PARA A CIDADE DE SANTA MARIA/RS / COMFORT ASSESSMENT THERMAL ONE BUILDING FOR SANTA MARIA CITY / RS

Santos, Eudes Vinícius dos 21 October 2015 (has links)
Sheep production has always played a fundamental role in society throughout history, and it has been highlighted as an important economic activity in Rio Grande do Sul, Brazil. Rio Grande do Sul presents climatic peculiarities that in some situations impose a condition of thermal discomfort in animals, generating heat stress, which is one of the main limiting factors of animal production. Seeking alternatives that provide better thermal comfort for confined animals and a consequent greater production is essential. This study was carried out with sheep and lambs confined in a fold (fenced enclosure area) at Universidade Federal de Santa Maria and aimed to evaluate the thermal comfort that the fold gives animals in a typical winter and summer day. We assessed environmental variables such as air temperature, radiant temperature, relative humidity, and air velocity. Subsequently, the Black Globe and Humidity Index (BGHI) and Thermal Comfort Index (TCI) were utilized to evaluate animal thermal comfort. Additionally, rectal temperature, respiratory rate, and skin temperature of the animals as well as thermographic images of the wool surface of the (fur) animals and fold were evaluated. Based on data gathering and calculation of the indices, it was possible to observe that the animals were in thermal discomfort for most part of the experiment. For the typical winter period, no reference values of BGHI and TCI were found; however, some animals had a rectal temperature of 35.5 ° C, which is below normal levels. The fold had thermal cushioning below 28%, imposing internal temperatures of 7.8 ° C in the animals. This temperature is out of the thermal comfort zone (TCZ), which lies between 25 and 30 ° C for newborns and between 15 and 30 ° C for adult animals, being close to 6 ° C, which is considered lower critical temperature (TCL). For the typical summer period, the building had a heat buffer below 10% and it was possible to assess comfort using BGHI and TCI. During the morning, BGHI was below 74, which represents thermal comfort values. On the other hand, the fold in the afternoon presented BGHI ranging between 74 and 79, which represents state of alert. As a conclusion, the fold studied does not provide thermal comfort for animals in most of the typical winter and summer period. As a consequence, it requires constructive improvements to ensure that animals are provided with comfort and well-being so that they reach their maximum productive and reproductive performance. / A ovinocultura exerce papel fundamental na história e na pecuária do Rio Grande do Sul e vem se destacando como importante atividade econômica no Brasil. O Rio Grande do Sul, por sua vez, apresenta peculiaridades climáticas que impõem aos animais, em algumas situações, uma condição de desconforto térmico, gerando o estresse térmico, que é um dos principais fatores limitantes da produção animal. Portanto, torna-se imprescindível a busca por alternativas de conforto térmico que proporcionem bem estar aos animais e que gerem maior potencial na sua produção, principalmente em ambientes protegidos. Pretendeu-se, com este trabalho, avaliar o conforto térmico que a edificação, denominada aprisco (instalação para ovinos) proporciona aos animais (cordeiros e borregos) confinados no laboratório de ovinocultura da Universidade Federal de Santa Maria, para um dia típico de inverno e um dia típico de verão, por meio do levantamento das variáveis ambientais, tais como temperatura do ar, temperatura radiante, umidade relativa, velocidade do ar e posterior cálculo do Índice de Temperatura de Globo Negro e Umidade (ITGU) e do Índice de Conforto Térmico (ICT), ambos índices para avaliar o conforto térmico animal. Também foram realizadas a coleta da temperatura retal, da frequência respiratória e da temperatura da epiderme dos animais, bem como o levantamento de imagens termográficas da superfície da lã (vélo) dos animais e do aprisco. Foi possível avaliar, com base nos levantamentos de dados e no cálculo dos índices, que os animais estavam em desconforto térmico na maior parte do experimento. Para o período típico de inverno, não foram encontrados valores de referência dos índices ITGU e ICT; no entanto, alguns animais apresentaram temperatura retal de 35,5°C, abaixo do normal. A edificação (aprisco) teve um amortecimento térmico abaixo de 28%, impondo aos animais, temperaturas internas de 7,8°C, isto é, fora da zona de conforto térmico (ZCT), que se encontra entre 25 e 30°C para animais recém-nascidos e entre 15 e 30°C para animais adultos, estando mais próximas de 6°C, considerada temperatura crítica inferior (TCI). Para o período típico de verão, a edificação apresentou amortecimento térmico abaixo de 10% e foi possível avaliar o conforto através dos índices, ITGU e ICT. Durante o período da manhã, o ITGU ficou abaixo de 74, o que representa valores de conforto térmico. Já no período da tarde, as instalações apresentaram ITGU compreendidos entre 74 e 79, o que significa situação de alerta. Portanto, ao fim do experimento, foi constatado que a edificação (aprisco) não proporciona conforto térmico aos animais na maior parte do período típico de inverno e verão. Por fim, entendeu-se que a edificação existente precisa de melhorias construtivas para que os animais disponham de conforto e bem estar para que atinjam seu máximo rendimento produtivo e reprodutivo.
73

A produção recente de edifícios residenciais em São Paulo: desempenho e conforto térmico no contexto urbano e climá¡tico em transição / The recent residential building production in São Paulo: performance and thermal comfort in the urban and climate transition context

Alves, Carolina Abrahão 17 April 2019 (has links)
O objeto deste trabalho é o desempenho térmico da produção recente de edifícios residenciais multifamiliares em São Paulo, lançados entre 2005 e 2014, considerando o contexto urbano e climático em transição, visando às condições de conforto térmico. O objetivo é quantificar, por meio de estudos paramétricos com simulações computacionais termodinâmicas, o efeito de elementos, tanto intrínsecos quanto externos, aos edifícios sobre as condições de conforto térmico no clima atual e, em um segundo momento, no futuro (cerca de 50 anos à frente) identificando as melhores estratégias de projeto e operação para o conforto térmico. A hipótese é de que algumas práticas de projeto e operação correntes nos edifícios residenciais multifamiliares, que incluem o uso da varanda como ambiente interno da unidade e a vedação envidraçada de maiores proporções, tudo isso conjugado com as pequenas dimensões das unidades e os decorrentes prejuízos à ventilação natural, fazem com que esse estoque edificado, operando em modo naturalmente ventilado, apresente um desempenho térmico insatisfatório para o conforto térmico, e que isso vai ocorrer em uma parcela considerável do tempo de uso. No entanto, a varanda, valorizada nos edifícios residenciais multifamiliares verticais recentes, quando usada de fato como elemento de transição, consegue ser o vetor de melhoria do conforto térmico interno através da promoção de diferentes possibilidades de operação, incluindo sombreamento e ventilação. O estudo parte de uma leitura de grandes temas relacionados, passa por estudos de casos reais de apartamentos residenciais e estudos de clima urbano e realiza simulações computacionais termodinâmicas de desempenho térmico de uma unidade residencial considerada representativa da produção recente do mercado imobiliário de edifícios verticais multifamiliares. O método é indutivo, por meio de levantamentos de dados e elaboração de um modelo representativo (Ap Base) para as simulações computacionais, e dedutivo, por meio de comparações entre os diversos resultados obtidos pelas simulações computacionais nas diferentes configurações propostas. Dos estudos de simulação computacional depreende-se que, para os padrões construtivos de unidades residenciais em edifícios verticais praticados pelo mercado, alcançar o conforto ambiental em modo de operação naturalmente ventilado será um desafio de maiores dimensões nos cenários de aquecimento global e urbano vislumbrados. A diminuição de massa térmica aliada ao aumento das superfícies envidraçadas não sombreadas e reduzidas possibilidades de ventilação nos ambientes são os principais fatores que contribuem para o aquecimento em edificações. A presença da varanda, por sua vez, é positiva quando ela assume diversas possibilidades de configuração, atuando e sendo ocupada como um ambiente de transição de fato e não como um dos cômodos internos à residência; deste modo ela pode ser vetor das melhores práticas de operação na busca do conforto térmico. Portanto, os resultados comprovam a hipótese inicial, destacando-se que elementos que possibilitem a operação das aberturas, em especial aquelas ligadas à varanda, a saber, envidraçamento externo, porta entre varanda e estar e elemento sombreador externo, precisam estar disponíveis para serem operados pelo usuário, que deve estar apto a perceber as melhores possibilidades de operação e realizá-las. / The objective of this work is the thermal performance of the recent multifamily residential building production in São Paulo, launched between 2005 and 2014, considering the urban and the transition climate contexts aiming at the thermal comfort conditions. The objective is to quantify, through parametric studies using thermodynamic computational simulations, the effect of both intrinsic and external elements on the thermal comfort conditions in the current climate and, in a second moment, in the future about 50 years ahead, identifying the best design and operation strategies for the thermal comfort. The hypothesis is that some current design and operation practices in multifamily residential buildings, which include the use of the balcony as an interior environment and the large glass enclosures combined with the apartment\'s small area and the insufficient natural ventilation possibilities, result in poor thermal comfort performance of this free running building stock in a considerable part of its lifespan. However, the balcony, valued in the recent multi-family residential buildings, when in fact used as a transition space, can be the vector of internal thermal comfort improvements by promoting different operation possibilities, including shading and ventilation. This study starts from a broader context, observing real residential apartments\' study cases, going into urban climate studies and performing thermodynamic simulations of a residential apartment considered representative of the recent vertical multifamily building production of the local real estate market. The method is inductive, through data surveys and elaboration of a representative model (Ap Base) for the simulations, and deductive, through comparisons between the several results obtained by the simulations in the different configurations proposed. From the simulation studies, it can be concluded that, for the building standards of residential apartments in vertical buildings practiced by the market, achieving thermal comfort in free running mode will be a major challenge in the envisioned global and urban heating scenarios. The decrease of the thermal mass coupled with the unshaded large glazed surface area and reduced ventilation possibilities are the main factors for the building heating. The balcony, in turn, is positive when it assumes several configuration possibilities, acting and being occupied as a transitional environment in fact and not as an interior room; in this way it can be a vector of the best operating practices in the search for thermal comfort. Therefore, the results confirm the initial hypothesis, emphasizing that elements allowing the opening operation, especially the ones connected to the balcony, namely external glazing, door between balcony and living room and external shade element, must be available to be operated by the user, who must be able to perceive the best possible operation and perform it.
74

Adaptação tecnológica para teto de habitação social: estudo de caso em Tuxtla Gutiérrez, Chiapas, México / Technological adaptation for roof of social dwelling: study case in Tuxtla Gutierrez, Chiapas, Mexico

Castañeda Nolasco, Gabriel 17 October 2008 (has links)
O presente trabalho trata de um dos componentes da habitação social, o teto, que por suas características técnico-construtivas é o mais complexo dos seus componentes. A pesquisa foi desenvolvida em Tuxtla Gutiérrez, Chiapas, México, entre as atividades do programa 10x10, do projeto XIV.5 con techo, subordinado ao sub programa XIV, tecnologías para vivienda de interés social HABYTED de CYTED. Pelas atividades realizadas com o grupo técnico do programa citado, o objetivo principal foi desenvolver uma adaptação da tecnologia para teto Domozed ao contexto de Tuxtla Gutiérrez, Chiapas, México, orientada a melhorar a transferência tecnológica para habitação social. Esta tecnologia é utilizada no Peru e foi difundida em diversos países de América Latina, assim como muitas outras tecnologias cedidas pelos membros da equipe de trabalho do programa 10x10 con techo. As experiências vividas evidenciaram a necessidade de adaptação das tecnologias difundidas aos contextos selecionados, para sua melhor aceitação e funcionamento ou para sua realização. Partiu-se da hipótese que as tecnologias difundidas pelos membros participantes do programa 10x10, ao serem desenvolvidas para contextos específicos e pretender transferi-las a outros, sua apropriação ao novo contexto está condicionada por sua adaptação. O resultado foi o sistema de teto Domotej com a integração da análise de cinco variáveis priorizadas (processo construtivo, resistência mecânica, preço, desempenho térmico y aceitação social), que permitiram o desenvolvimento da adaptação; onde foi construído para sua avaliação, um protótipo experimental de moradia com o que se comprovou a viabilidade de construção e no contexto social do bairro Julio Cesar Ruiz Ferro, foi explorada a possibilidade de sua transferência. / The present work is about one of the components of the social dwelling, the roof, which is the most complex of the elements that make it a reality, due to its technician-constructive characteristics. The research project was developed in Tuxtla Gutierrez, Chiapas, Mexico, in the mark of activities of the program 10x10, of the project XIV.5 with roof, dependent on the sub program XIV, technologies for housing of social interest HABYTED of CYTED. For the achieved activities with the technical group of the mentioned project, the main objective was the adaptation of the roof Domozed to the study context. This roof technology is used in Peru and it has been diffused to different countries of iberoamerica, the same as many other technologies contributed by the members of the work team of the program 10x10 with roof. The lived experiences showed the adaptation need of the technologies diffused to the chosen contexts, for their best acceptance and function or simply for their realization. We started from the hypothesis that the transference of technologies diffused by the participant members of the program 10x10, when having been developed for specific contexts and intend to transfer them to other different contexts, their production, function, economic viability and social acceptance are conditioned by their adaptation, according to the necessity of making them appropriate and appropriable to the new context The result was the integration of the analysis of five prioritized variables (constructive process, mechanical resistance, price, thermal performance and social acceptance), what allowed the development of the adaptation, which was evaluated by the construction of an experimental prototype of dwelling proving the construction feasibility and in the social context of the neighborhood Julio Cesar Ruiz Ferro, the possibility of its transfer was explored.
75

Adensamento habitacional na cidade de São Paulo: procedimentos para avaliação de desempenho térmico, acústico e luminoso / Housing densification in the city of São Paulo: procedures for assessing termal, accoustic and luminous performance

Guilhon, Vanessa Valdez 24 April 2015 (has links)
Esta pesquisa teve como ponto de partida o viés do adensamento em áreas urbanas consolidadas - dotadas de infraestrutura, serviços urbanos e ofertas de emprego - servindo de alternativa à expansão periférica, apresentando-se como potencial para a produção habitacional e para o adensamento construtivo. E assim, uma questão se fez pertinente: construir com o coeficiente de aproveitamento (C.A.) máximo permitido pela legislação urbana (Plano Diretor Estratégico do município de São Paulo), numa dada área da cidade, é uma garantia do atendimento da qualidade ambiental de seus edifícios? A pesquisa foi estruturada na busca por responder a esta questão. Seu objeto é a implantação dos edifícios residenciais na cidade de São Paulo, dentro do contexto de C.A. máximo permitido pela legislação. Como objetivo tem-se o estabelecimento de procedimentos para avaliação de desempenho térmico, acústico e luminoso das unidades habitacionais dos edifícios implantados na quadra de estudo, em área central da cidade de São Paulo. O método é essencialmente analítico com base na ferramenta de simulação computacional TAO: uma metodologia para implantação de edificação - ênfase no desempenho térmico, acústico, luminoso e energético (ALUCCI, 2007), para a entrada de dados e modelagem da quadra de estudo. O trabalho incluiu procedimentos de levantamento de dados primários através de pesquisa de campo. Como produto da tese tem-se: (I) critérios ambientais que orientarão as escolhas dos arquitetos quanto às distintas alternativas de implantação da edificação no terreno, (II) a flexibilização das decisões de projeto, considerando a realidade local e contemplando, principalmente, as intenções e o partido adotado pelo arquiteto, (III) ao optar por qualquer alternativa de implantação, é possível estimar o desempenho da edificação para todos os critérios de desempenho, (IV) resultados distintos do 1° e do último pavimento tipo, o que aponta a necessidade de projeto de pavimento tipo diferentes, o que ordenará o desenho do edifício, (V) metodologia para avaliação de desempenho térmico, acústico e luminoso do edifício, (VI) proposta de ocupação de quadra e avaliação de desempenho térmico, acústico e luminoso das edificações. / This research took as a starting point the densification of consolidated urban areas - with infrastructure, urban services and jobs - as an alternative to peripheral expansion, posing as potential for housing production and the constructive consolidation. So a question became relevant: Does the use of maximum Floor Area Ratio (FAR) allowed by the urban legislation (Strategic Master Plan of São Paulo) in a given area of the city ensure compliance with environmental quality of its buildings? The research was structured aiming to answer this question. The object of investigation is the implementation of the residential buildings in the city of São Paulo within the maximum FAR allowed by law. The objective has been to establish procedures for assessing thermal, acoustic and luminous performance of housing units in buildings of the study block, in the central area of São Paulo. The method is essentially analytical, based on computational simulation tool TAO: methodology for building\'s site planning to optimize thermal, acoustics, lighting and energy performance (ALUCCI, 2007), for the input of data and modeling study block. The work included collection of primary data through a field survey. As the product of the research we have: (I) environmental criteria to guide the choice of architects among different alternative for site plans, (II) the flexibility of design decisions, considering the local reality and contemplating mainly the approach adopted by the architect, (III) Once the site plan is defined it is possible to estimate the performance of the building for various criteria, (IV) different results of the 1st and last floor type, which points the need for different types of design for the ground floor, (V) methodology for evaluating thermal performance, acoustic and light of buildings, (VI) block site plan proposal and evaluation of its thermal, acoustic and luminous performance.
76

Avaliação da aplicação do modo misto na redução da carga térmica em edifícios de escritórios nas cidades de São Paulo e Rio de Janeiro / Evaluation of mixed-mode application for thermal load reduction in office buildings at the cities of São Paulo and Rio de Janeiro

De Benedetto, Gisele Saveriano 13 April 2007 (has links)
Diante das atuais questões ambientais, o uso eficiente da energia é uma premissa em todos os setores de atividades. Sabe-se que as edificações são grandes consumidores de energia e boa parcela desse consumo se dá em sistemas de condicionamento artificial. São três os principais fatores que atuam no balanço térmico e influenciam esse consumo: arquitetura, ocupação e clima. A arquitetura atua como intermediária nesse balanço térmico, podendo ajudar ou prejudicar as condições internas. Este trabalho estuda o desempenho térmico e energético dos edifícios de escritórios em São Paulo e Rio de Janeiro, cidades que apresentam condições extremas de calor durante o verão e até em outras estações do ano. O tipo de ocupação e a atividade realizada em edifícios de escritórios nos dias de hoje criam, por si sós, cargas térmicas elevadas que dificultam ainda mais a obtenção de conforto. Este trabalho parte do pressuposto de que existem soluções arquitetônicas de edifícios de escritórios na cidade de São Paulo capazes de garantir conforto térmico aos usuários durante parte do período de ocupação sem uso de condicionamento artificial, porém acreditar que é possível obter conforto apenas com sistemas passivos durante o ano todo nos atuais edifícios de escritórios das cidades de São Paulo e Rio de Janeiro é ilusão. Diante desse desafio, o sistema de modo misto de condicionamento ambiental une as vantagens do sistema ativo às do passivo, operando com sistemas naturais sempre que possível, reduzindo o consumo de energia e acionando o sistema ativo em situações fora das condições de conforto. Utilizar o sistema de modo misto não significa abrir as janelas de qualquer edifício no inverno. O edifício deve estar preparado para o sistema desde as etapas de projeto. Com base nesse pensamento, a pesquisa analisa o desempenho térmico e energético de três tipologias arquitetônicas operando com o sistema de modo misto em São Paulo e investiga o desempenho das mesmas tipologias sob as condições climáticas da cidade do Rio de Janeiro. As avaliações de desempenho térmico e energético das tipologias são feitas por meio de análises e comparações de resultados de simulações computacionais com o programa TAS (9.0.7 maio, 2005). / Considering current environmental issues, all sectors of activities are premised on the efficient use of energy. Its known that constructions are great energy consumers and part of this consumption is given by artificial conditioning systems. Therere three main factors in thermal balance that influences this consumption: architecture, occupation and climate. The architecture acts as intermediate in this thermal balance, being able to help or harm internal conditions. This research treats office building thermal and energy performance in São Paulo and Rio de Janeiro, cities with high temperatures not only during the summer but also in other seasons. Nowadays, offices occupation and activity are themselves great heat producers, what makes thermal comfort even more difficult to achieve. This project considers that there are office building design solutions able to produce thermal environmental conditions acceptable to a majority of occupants, without air-conditioning system, during part of the working period, in São Paulo. However, believing the possibility of achieving comfort conditions in actual office buildings, only with passive cooling strategies, during all year, in the cities of São Paulo and Rio de Janeiro, is an illusion. Facing this challenge, mixed mode system combines the best of air-conditioning and natural ventilation, operating with natural strategies whenever its possible, reducing energy consumption and using the air-conditioning system only when thermal environmental conditions are not acceptable. Mixed mode operation does not mean to open any building windows during the winter. The building must have been designed for the mixed mode system since its first projects. This research is based on this thought and thermal analysis and energy performance of three architectural design buildings operating with mixed mode system in São Paulo and investigates the performance of these building types under climate conditions of Rio de Janeiro city. The thermal and energy performance evaluations of the building types are based on the analysis and comparison of computer simulations results, with the software TAS (9.0.7 May, 2005).
77

Estudo das propriedades mecânicas e físicas de um traço comercial de concreto autoadensável com e sem substituição de cinza de casca de arroz

Padoin, Daniela Galiotto 24 April 2017 (has links)
Submitted by Cátia Araújo (catia.araujo@unipampa.edu.br) on 2017-09-29T12:41:16Z No. of bitstreams: 1 Daniela Galiotto Padoin - 2017.pdf: 4389550 bytes, checksum: dc20fb8e625f388d3aa85db0857a79aa (MD5) / Approved for entry into archive by Marlucy Farias Medeiros (marlucy.farias@unipampa.edu.br) on 2017-09-29T16:24:47Z (GMT) No. of bitstreams: 1 Daniela Galiotto Padoin - 2017.pdf: 4389550 bytes, checksum: dc20fb8e625f388d3aa85db0857a79aa (MD5) / Made available in DSpace on 2017-09-29T16:24:48Z (GMT). No. of bitstreams: 1 Daniela Galiotto Padoin - 2017.pdf: 4389550 bytes, checksum: dc20fb8e625f388d3aa85db0857a79aa (MD5) Previous issue date: 2017-04-24 / Neste trabalho, foram estudadas as propriedades físicas, mecânicas, acústicas e térmicas de um traço de Concreto autoadensável (CAA) já utilizado por uma Usina de Concreto, e outros três traços com substituição de cimento Portland (CP) por Cinza de casca de arroz (CCA). O traço referência (sem substituição) foi utilizado na construção de um Edifício de parede de concreto. Os ensaios foram definidos a fim de ser possível a análise tanto da resistência à compressão e resistência à tração diametral, quanto o conforto térmico e acústico apresentado por esse material, quando comparado com o que é normatizado. Para isso, foram realizados os ensaios no estado fresco, garantindo as especificações de todas as propriedades exigidas para um concreto ser considerado autoadensável. Após essa caracterização, moldaram-se os corpos de prova necessários para todos os ensaios do estado endurecido, sendo corpos de prova cilíndricos (100x200mm) para ensaios mecânicos, cilíndricos (20x100mm) para ensaios acústicos e retangulares (300x300x100mm) para ensaios térmicos. No quesito de resistência à compressão, superou o fck estabelecido aos 28 dias, que era de 25 MPa. Analisando os valores encontrados para absorção e isolamento acústico, pode-se dizer que apresentaram resultados satisfatórios na menor faixa de frequência e, na maior, apresentaram alguns problemas que acredita-se serem referentes ao equipamento utilizado. No desempenho térmico, todos os traços, apresentaram resultados próximos entre si e a outros estudos da bibliografia e normas, não sendo influenciado pela substituição da CCA. Os resultados dos ensaios demonstraram que é possível substituir CP por CCA sem que haja prejuízo às características mecânicas os CAAs, e ainda obter ganhos econômicos. O melhor concreto, levando em conta todos os aspectos estudados, foi com 20% de substituição de CP por CCA. / In this work the physical, mechanical, acoustic and thermal properties of a Self-consolidating concrete (SCC) mix design already used by a concrete plant and others three mix design with Portland cement (PC) replacement by Rice husk ash (RHA) were studied. The reference mix design (without replacement) was used in the construction of a concrete wall building. The experimental tests were defined in order to allow the analysis of both the compressive strength and diametral tensile strength, as well as the thermal and acoustic comfort presented by this material, Thus, the tests were realized in the fresh state, guaranteeing the specifications of all properties required for a concrete to be considered self-consolidating. After this characterization, the necessary specimens were molded for all the hardened state tests, being cylindrical specimens (100x200mm) for mechanical tests, cylindrical (20x100mm) for acoustic tests and rectangular (300x300x100mm) for thermal tests. The compressive strength exceeded the fck established at 28 days, which was 25 MPa. Analyzing the values found for absorption and acoustic insulation, it can be said that they presented satisfactory results in the lower frequency range and, in the higher, presented some problems that are believed to be referring to the equipment used. In the thermal performance, all the mix design present close results among themselves and other studies of the bibliography and norms, not being influenced by replacement of the RHA. The tests results demonstrated that it is possible to replacement PC for RHA without impairing the mechanical features of the SCCs as well as to obtain economic gains. The best concrete, taking into account all aspects studied, was with a 20% replacement of PC for RHA.
78

O desempenho térmico de um sistema de cobertura verde em comparação ao sistema tradicional de cobertura com telha cerâmica. / The thermal performance of green roof system in comparison to the traditional ceramic tile roof system.

Ferraz, Iara Lima 29 March 2012 (has links)
As coberturas verdes fazem parte da arquitetura vernacular há séculos como solução para regulação térmica das edificações, retardando a transferência de calor para o ambiente interno e, no inverno, retardando as perdas de calor dos ambientes internos para o exterior da edificação (International Green Roof Association - IGRA). Em se adotando cobertura verde em edificações supõe-se haver economia no consumo de energia para se obter condições de conforto térmico nos ambientes. Baseado nessa suposição foi realizada uma pesquisa experimental onde, por meio de um estudo comparativo entre dois tipos de cobertura: a verde e a de telhas cerâmicas comprovou-se o potencial de economia de energia. A análise do comportamento térmico das coberturas verdes foi realizada por meio de coleta de dados de variáveis ambientais, durante um período de 10 meses, de um protótipo instrumentado, construído no Departamento de Engenharia de Construção Civil da Escola Politécnica da USP, São Paulo. Os dados levantados foram comparados com os dados de um segundo protótipo de mesmas dimensões e igualmente instrumentado, com cobertura cerâmica, sob as mesmas condições ambientais. A comparação dos resultados e análises em dias e episódios representativos de cada estação comprovaram a eficiência das coberturas verdes para retardar o ganho térmico da edificação. Espera-se que os resultados sejam incentivadores à larga aplicação dos telhados egetados, o que trará diversas vantagens para população. / Green roofing is been a part of the vernacular architecture for centuries as solution for constructions thermal regulation. It is known that they delay the heat transfer from the outside to the inside of the building, and during winter, they delay the heating loss from the inside to the outside of the building (International Green Roof Association - IGRA). By adopting green roofs in buildings, one assumes that there is economy in energy consumption to obtain conditions of thermal comfort in inner environments. Based on this assumption, an experimental research was accomplished where, through a comparative study between two types of roofing systems: green and ceramics, it was determined this energy saving potential of green roofs. The analysis of the green roofing thermal behavior was realized through data collection of environmental variables, during the period of ten months, from an instrumented prototype constructed at the Polytechnic School of the University of São Paulo, São Paulo. The collected data was compared to those of a second prototype with the same dimensions and equally instrumented, with ceramics roofing, under the same environmental conditions. The data comparison and analysis of specific days in each season, proved the green roof efficiency on retarding the building thermal gain. One expects that the results will encourage the application of green roofs, which will bring several advantages to the population.
79

Desempenhos térmico e energético de uma edificação na região amazônica brasileira / Thermal and energetic performances of a building in the Brazilian Amazon region

AGUILAR, Heliana Maria Ceballos 06 September 2018 (has links)
Submitted by Luciclea Silva (luci@ufpa.br) on 2018-11-19T17:22:42Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_Desempenhostermicoenergetico.pdf: 10712131 bytes, checksum: 3079c110358b7ad51bae0926fe393b78 (MD5) / Approved for entry into archive by Luciclea Silva (luci@ufpa.br) on 2018-11-19T17:23:01Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_Desempenhostermicoenergetico.pdf: 10712131 bytes, checksum: 3079c110358b7ad51bae0926fe393b78 (MD5) / Made available in DSpace on 2018-11-19T17:23:01Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_Desempenhostermicoenergetico.pdf: 10712131 bytes, checksum: 3079c110358b7ad51bae0926fe393b78 (MD5) Previous issue date: 2018-09-06 / diminuir o consumo de energia, onde é avaliado o impacto de cada uma delas individualmente, e todas em conjunto, nos comportamentos térmico, energético e econômico de uma edificação localizada na Região Amazônica Brasileira. Esta região é caracterizada climaticamente pelas altas temperaturas e umidade, onde alcançar condições adequadas de conforto implica em um alto consumo de energia com sistemas de condicionamento de ar. Diferentes Medidas de Conservação de Energia são avaliadas, com o objetivo de alcançar um melhor aproveitamento da iluminação natural; diminuir as cargas térmicas para resfriamento, onde se considera a instalação de um material isolante térmico nas paredes leste e oeste, e de um isolante térmico e câmara de ar na cobertura, que são as superfícies externas que recebem maior radiação solar na edificação; e também vários sistemas de geração fotovoltaica, sendo que um dos sistemas está integrado como elemento arquitetônico e outro está adaptado sobre a cobertura da edificação. Na edificação são realizados dois tipos de análise: dinâmica e estática. Para a análise dinâmica utiliza-se o programa EnergyPlus, para conhecer seu comportamento térmico e de consumo de energia analisados para o ano inteiro e para os dias de projeto, e o programa Daysim/Radiance para conhecer a autonomia de iluminação natural alcançada, para tanto usando-se dados medidos por uma estação meteorológica instalada no local. Com relação à análise estática, é avaliado o nível de eficiência energética da edificação pelo método prescritivo segundo a regulamentação nacional vigente. Posteriormente, a mesma edificação é simulada para as nove capitais dos estados da Região Amazônica Legal Brasileira, com o intuito de conhecer o comportamento energético e a viabilidade econômica em resposta às características climáticas e tarifas de energia elétrica de cada cidade. Com as avaliações realizadas determina-se que as Medidas de Conservação de Energia (MCE) têm influência direta e significativa sobre a diminuição da carga térmica para resfriamento, pela redução dos efeitos da radiação, com o sombreamento nos beirais e a redução da transmitância das superfícies tratadas. Comprova-se também a possibilidade de maximizar a iluminação natural em espaços internos, para melhorar o conforto dos usuários, possibilitando seu melhor desempenho e economia em energia usada em iluminação artificial. Em termos de consumo de energia e viabilidade econômica, as MCE alcançam uma economia energética anual de até 52 % na edificação tomada como estudo de caso, e as soluções adotadas apresentam retorno do investimento financeiro, mostrando-se também adequadas para a economia de energia e viáveis economicamente em regiões com características climáticas similares. / This work presents an innovative proposal of integration of several strategies to reduce energy consumption, where the impact of each one of them is evaluated individually, and all together, in the thermal, energetic and economic performance of a building located in the Brazilian Amazon Region. High temperature and humidity characterize this region climatically, where achieving adequate comfort conditions implies a high demand for energy for air conditioning systems. Different Energy Conservation Measures are evatuated in order to achieve a better use of daylighting; and to reduce thermal loads for cooling, with the installation of a thermal insulation material in the eastern and western walls, and a thermal insulation and air chamber in the roof, which are the external surfaces that receive higher solar radiation in the building. Additionally, various photovoltaic generation systems are considered, one of which is integrated as an architectural element and another adapted on the roof of the building. In the building, two types of analysis are conducted: dynamic and static. For the dynamic analysis, the EnergyPlus software is used to know its thermal and energy consumption performances, analyzed for the entire year and for the design day, and the Daysim/Radiance software to know the autonomy of daylighting attained, using data measured with an on-site meteorological station. Concerning the static analysis, the level of energy efficiency is evaluated by the prescriptive method according to the current national regulations. Subsequently, the same building is simulated for the nine capital cities of the states of the Legal Brazilian Amazon Region, with the aim of knowing its energetic performance and the economic feasibility depending on the climatic characteristics and electrical energy tariffs of each city. With the assessments performed, it is determined that the ECM have a direct and significant influence on the reduction of the thermal load for cooling, through the reduction of radiation effects, the shading in the eaves and the reduction of the transmittance of the surfaces treated. The possibility of maximizing the daylight in internal spaces, to improve the comfort of the users is also verified, allowing better performance and energy savings with artificial lighting. In terms of energy consumption and economic feasibility, the ECM achieve an annual energy savings of 52 % in the building taken as a case study, and the solutions adopted show a good return on financial investment, and are also suitable for energy saving and economically feasible in regions with similar climatic characteristics.
80

Investigação da viabilidade da redução do consumo de energia elétrica em edificações residenciais através da aplicação de soluções de conforto ambiental passivo / Investigation of the viability of reducing energy consumption in residential buildings through the implementation of passive strategies for environmental comfort

Pires, Josiane Reschke 21 March 2013 (has links)
Submitted by Maicon Juliano Schmidt (maicons) on 2015-04-18T14:41:17Z No. of bitstreams: 1 Josiane Reschke Pires.pdf: 4785187 bytes, checksum: 5dcede27f6c8d94cee536d3dfbfa047d (MD5) / Made available in DSpace on 2015-04-18T14:41:17Z (GMT). No. of bitstreams: 1 Josiane Reschke Pires.pdf: 4785187 bytes, checksum: 5dcede27f6c8d94cee536d3dfbfa047d (MD5) Previous issue date: 2013-03-21 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / PROSUP - Programa de Suporte à Pós-Gradução de Instituições de Ensino Particulares / A preocupação com a sustentabilidade sugere a busca pela otimização dos recursos naturais. Um dos aspectos necessários é adequar as edificações para o clima em que estão localizadas, reduzindo o consumo energético da habitação e ampliando o conforto ambiental. O objetivo desta pesquisa é investigar a viabilidade técnica e econômica da aplicação de critérios de desempenho térmico em edificações residenciais. A investigação foi centrada na identificação dos custos e da energia no ciclo de vida de projetos simulados com soluções baseadas em conforto ambiental passivo (natural) e ativo (artificial), verificando a influência no consumo de energia da edificação. Foi aplicada em projetos de edificações residenciais verticais e horizontais, de classe média e baixa, em dois climas distintos (Porto Alegre e Bento Gonçalves, RS), examinando o tipo de envelope, as absortâncias e o uso de elementos construtivos. Para análise do desempenho térmico foi adotada a norma de desempenho NBR 15575 e método graus-hora, com modelagem BIM, utilizando o Revit/Autodesk e para as simulações térmicas foi empregado o EnergyPlus, software especializado em análise energética para edificações. O ciclo de vida dos projetos propostos foi analisado considerando-se um período de 50 anos, comparando os custos e a energia incorporada das alternativas. Como um segundo parâmetro de sustentabilidade, também se analisou a eficiência energética conforme o selo de eficiência energética Procel Edifica. Os resultados indicam que com o aumento do isolamento da envoltória se verifica uma melhoria do conforto térmico, de até 54%, e economia de energia, em ambos os climas, com um período de retorno de 2 a 6 anos, em alguns casos. / The concern with sustainability brought the need for optimization of the energy resources to reduce the consumption of electric energy and of natural resources. One of the aspects is the need to adapt the buildings to the climate in which they are located, reducing the energy consumption of housing. The aim of this research is to investigate the technical and economic viability of applying some criteria of thermal performance in residential buildings. The methodology is based on the identification of the costs and energy in the life cycle of projects based on environmental comfort on passive (natural) and active (artificial) ways, detailing the influence on energy consumption of the building. It was applied in residential projects, both vertical and horizontal, of lower and middle class, in two distinct microclimates (Porto Alegre and Bento Gonçalves, southern Brazilian cities), examining alternatives of envelope, insulation and the use of architectural façade elements. To analyze the thermal performance was adopted the Brazilian standard NBR 15575 and degree-hour method, with BIM modeling through Revit/Autodesk and for the thermal simulation Ecotect/Autodesk and EnergyPlus. The life cycle of the proposed case studies was analyzed by considering a period of 50 years, comparing the costs and embodied energy of alternatives. As a second measure of sustainability, energy efficiency was also analyzed with the Brazilian standard of energy efficiency Procel Edifica. The results showed that with the increment of envelope’s insulation there are improvement of thermal comfort, of 54%, and energetic economy, in both climates, with a payback period of 2 to 6 years, in some cases.

Page generated in 0.0883 seconds