• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 46
  • 10
  • 7
  • Tagged with
  • 64
  • 64
  • 26
  • 23
  • 20
  • 11
  • 10
  • 10
  • 10
  • 9
  • 9
  • 9
  • 9
  • 9
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Effets d'optique non-linéaire d'ordre trois dans les cavités à cristaux photoniques en silicium : auto-oscillations GHz dues aux porteurs libres et diffusion Raman stimulée

Cazier, Nicolas 13 December 2013 (has links) (PDF)
Dans ce travail de thèse, nous avons étudié des effets d'optique non-linéaire d'ordre trois dans les cavités à cristaux photoniques en silicium. Le premier d'entre eux est un phénomène d'auto-oscillations à haute fréquence (GHz) dans ces cavités, qui a pour origine une modulation de la transmission de la cavité due à l'interaction entre la dispersion due aux porteurs libres et l'absorption à deux photons. Nous avons observé ces auto-oscillations, pour la première fois, dans les nanocavités à cristaux photoniques silicium avec une fréquence de l'ordre de 3 GHz et une grande pureté spectrale. Nous avons développé un modèle pour analyser les mécanismes qui régissent l'apparition de ces auto-oscillations, ainsi que les amplitudes des fréquences fondamentale et harmoniques de ces oscillations. Ce phénomène d'auto-oscillations permettrait de réaliser des sources micro-ondes en silicium très compactes. Le deuxième phénomène étudié est celui de la diffusion Raman, qui est le seul moyen d'obtenir des lasers entièrement en silicium démontré jusqu'à présent. Cette diffusion Raman a été mesurée tout d'abord dans des guides d'onde à cristaux photoniques étroits (W0.63) de longueur 100 microns, où nous avons pu obtenir un nombre de photons Stokes allant jusqu'à 9, montrant ainsi que la diffusion Raman stimulée prédominait dans ces guides d'onde, bien que nous n'ayons pas pu y obtenir un effet laser Raman franc. Nous avons ensuite mesuré la diffusion Raman dans des nanocavités doublement résonantes conçues spécifiquement à partir de ces guides d'ondes pour optimiser l'effet Raman, avec des facteurs de qualités allant jusqu'à 235000 pour la résonance Stokes. Bien que nous n'ayons pu mesurer que de la diffusion Raman spontanée dans ces cavités, avec un facteur de Purcell de 2.9, l'étude théorique que nous avons effectuée sur les lasers Raman, et qui s'accorde parfaitement avec les résultats expérimentaux, montre qu'il serait possible d'obtenir un laser Raman dans ces cavités avec un seuil en dessous du milliwatt à condition de diminuer ces pertes dues à l'absorption par porteurs libres. Ceci pourrait être accompli en diminuant le temps de vie des porteurs libres, par exemple en les retirant du silicium à l'aide d'une jonction MSM.
32

Etude expérimentale de la modification des instabilités paramétriques en plasmas multiples.

Yahia, Vincent 12 May 2014 (has links) (PDF)
La présence simultanée de plusieurs plasmas le long de la trajectoire d'un faisceau laser énergétique est susceptible de modifier de manière importante le comportement des instabilités paramétriques par rapport au cas où un seul plasma est présent. Afin d'identifier les différents effets pouvant intervenir dans ce type de situation, un système de cible double dont l'écartement est ajustable a été développé, la première cible étant une mousse de faible densité et la seconde une feuille de plastique. Une partie de cette thèse est consacrée à la caractérisation de l'interaction dans les mousses seules, cette dernière étant encore peu connue à l'heure actuelle pour de si faibles densités. Dans le cas d'interaction en présence de deux plasmas, nous analysons successivement trois effets : celui du mélange hydrodynamique des deux plasmas, celui de l'incohérence induite par plasma et enfin celui du couplage électromagnétique entre les deux plasmas. Pour la première fois, il a été mis en évidence que l'incohérence induite par plasma sur un faisceau conduisait à la réduction de la rétrodiffusion Brillouin dans un plasma séparé. En revanche, cette incohérence ne parvient plus à compenser les effets hydrodynamiques se produisant par collision des plasmas lorsque ceux-ci sont suffisamment proches. Le couplage électromagnétique entre les plasmas affecte plus particulièrement la rétrodiffusion Raman, lorsque la rétrodiffusion du plasma de feuille traverse le plasma de mousse. Outre une réamplification du signal rétrodiffusé qui est un phénomène recherché dans l'amplification d'impulsions laser en milieu plasma, nous avons observé le développement de l'instabilité Raman dans une zone de plasma dominée par l'amortissement Landau ce qui est la signature d'effets cinétiques importants.
33

Synthèses de nanocarbones fluorés pour le stockage électrochimique de l'énergie

Ahmad, Yasser 04 October 2013 (has links) (PDF)
Dans les piles primaires au lithium, l'anode de lithium peut être couplée principalement à quatre matériaux de cathode (MnO2, SO2, SOCl2 et des composés fluorés CFx). Les piles Li/CFx présentent de nombreux avantages tels qu'une densité d'énergie élevée (jusqu'à 2200 Wh.kg-1), un potentiel de décharge relativement élevé (environ 2,4 V vs Li+/Li) et une longue durée de vie (plus de 10 ans à la température ambiante). Au cours de ce travail, nous avons intensément étudié les propriétés électrochimiques des carbones fluorés nanostructurés. Pour plus de performances, des précurseurs nanocarbonés de dimensionnalité différentes, et des procédés de synthèse gaz-solide variés ont été employés. Ainsi, des structures fermées comme les nanofibres de carbone (1D, tubulaire), ouvertes comme les nanodisques / nanocônes (2D en majorité, discotiques) et intermédiaires avec les noirs de carbone graphitisés. Chaque mode de synthèse a été optimisé en fonction du précurseur de départ (son facteur de forme, sa dimensionnalité, son degré de graphitisation ...). Pour remédier aux limitations des carbones fluorés commerciaux, leur mécanisme de décharge a été finement étudié afin d'améliorer notre compréhension sur la défluoration électrochimique d'une cathode CFx, et de les comparer aux CFx synthétisés au laboratoire, le but principal étant de dépasser les performances actuelles et de synthétiser des matériaux inédits pour la pile primaire au lithium. Des extracapacités par rapport aux valeurs théoriques dans les batteries Li/CFx ont été obtenues avec de nanocarbones fluorés spécifiques et le phénomène électrochimique à l'origine de cette extracapacité a été clairement expliqué.
34

Mise en oeuvre de biocapteurs en vue de la détection de pesticides dans l'eau par diffusion Raman exaltée / Implementation of biosensors for the detection of pesticides and pollutants in water by exalted Raman scattering

El Alami, Amal 20 April 2017 (has links)
La diffusion Raman exaltée de surface (SERS) est utilisée pour la mise au point d’un biocapteur capable de détecter des pesticides dans l’eau, en se basant sur le suivi de l’activité enzymatique de l’Acétylcholinestérase (ACHE). Les nanoparticules d’or sont utilisées comme substrats SERS actifs. Le signal Raman exalté de l’analyte est optimisé en testant plusieurs types de nanoparticules.Le Raman SERS a permis la détection directe du Paraoxon (PO) et du carbaryl (CA) et la possibilité de suivi de l’activité de l’ACHE. En absence d'inhibiteurs, la molécule d’acétylcholine (ATC) est transformée en acide acétique et en choline par l’enzyme ACHE. La mesure de l’activité de l’ACHE repose sur le suivi des concentrations en ATC car sa transformation est inhibée en présence de pesticides. Il a été ainsi possible d’établir une relation linéaire entre la concentration de pesticides et l’exaltation du signal Raman de l’ATC non transformé. La méthode a permis la détection du PO et du CA, avec une limite de détection beaucoup plus faible que la détection directe. Ce biocapteur basé sur l’activité de l’ACHE a ensuite été utilisé pour l'évaluation d’autres polluants (inhibiteurs d’ACHE) comme les additifs contenus dans les plastiques notamment. Enfin, nous avons développé une seconde approche qui consistait à mesurer l’activité de l’ACHE en utilisant la diffusion dynamique de la lumière. En effet, nous avons montré que les paramètres physicochimiques (agrégation) des AuNPs en contact avec certaines molécules, sont fortement influencés par l’activité enzymatique de l’ACHE. C’est ce phénomène d’instabilité qui nous a permis de distinguer entre les deux cas : absence et présence de PO. / Surface-enhanced Raman scattering (SERS) was used to develop a biosensor for the detection of pesticides through the monitoring of the enzymatic activity of acetylcholinesterase (ACHE). Gold nanoparticles (AuNPs) were used as an active SERS substrate. The enhanced Raman signal of the analyte is optimized by testing several types of nanoparticles. Raman SERS allowed the direct detection of Paraoxon (PO) and carbaryl (CA) pesticides and the possibility of follow-up of the activity of the ACHE. In the absence of inhibitors, the acetylcholine (ATC) is transformed into acetic acid and choline by the enzyme ACHE. The measurement of ACHE activity is performed through the monitoring of ATC concentrations because its transformation is inhibited in the presence of pesticides. Results showed a linear correlation between the concentration of pesticides and the SERS signal of the untransformed ATC. The method was optimized for the quantification of paraoxon and carbaryl with a limit of quantification much lower than the one obtained with a direct detection. Their identification was also possible using chemometrics. This biosensors, based on the ACHE activities, was applied to the evaluation of emergent pollutants: additives of commercial polymers. Our results suggested that most of the tested polymers contained molecules that act as inhibitors of the ACHE. Finally, we propose another very simple approach to measure the ACHE activity using dynamic light scattering measurements. We found that the physicochemical parameters (aggregation) of AuNPs were strongly influenced by the enzymatic activity of ACHE when in contact with specified molecules, allowing to detect the presence of PO.
35

Competing Orders in URu2Si2 : from ordered magnetism to spin liquid phases / Ordres en compétition dans URu2Si2 : de l’ordre magnétique aux phases de liquide de spin

Silva de Farias, Carlene Paula 10 April 2017 (has links)
L’objectif central de cette thèse est d’étudier des phases ordonnées en compétition dans des matériaux magnétiques présentant une structure cristalline tétragonale centrée.Ce travail est divisé en deux parties principales. Dans la première, nous présentons les résultats de notre étude de la compétition entre des états ordonnés antiferromagnétiques et des phases liquides de spin. Nous montrons comment ces dernières peuvent être stabilisées par la frustration géométrique et par une généralisation de la symétrie de spinau groupe SU(n). Les états antiferromagnétiques sont décrits par une théorie d’onde despin et l’analyse de liquide de spin est effectuée par une représentation fermionique des opérateurs de spin. Dans la deuxième partie, nous décrivons une théorie effective pour dércrire des expériences de diffusion Raman. Nous fournissons un aperçu de la phase d’ordre caché affichée par le composé de fermions lourds URu2Si2. / The main objective of this thesis is to investigate the competing ordered phases in the metallic heavy fermion compound URu2Si2, which displays a body-centered tetragonallattice. We first provide a study case of the competition between antiferromagnetic(AF) and spin liquid phases. The antiferromagnetic state is study with spin-wave theory. Whereas the spin liquid analysis has been carried out in an algebraic spin liquid representation.In the second part, we describe an effective theory for Raman scattering experiments at these particular phases. We provide insight about the hidden order phase displayed by the heavy fermion compound URu2Si2.
36

Description théorique des interférences de raies dans les spectres d'absorption et de diffusion de gaz moléculaire / theoretical description of the line mixing in the absorption and scattering spectra of the molecular gas

Daneshvar Salehi, Leila 06 June 2014 (has links)
La modélisation des interférences de raies dans des spectres de gaz moléculaires repose sur le concept de la matrice de relaxation dont les éléments diagonaux décrivent les raies isolées et les éléments non-diagonaux représentent le transfert d'intensité entre les raies. Ces éléments non-diagonaux sont modélisés en appliquant des lois d'échelle comme le modèle ECS (Energy-Corrected-Sudden). Nous avons considéré la molécule de CO2 car ce gaz joue un rôle important dans les atmosphères terrestre et planétaires. En plus, à cause de la petite valeur de sa constante de rotation, les raies se serrent et se chevauchent, donnant naissance à des interférences de raies. Grâce aux nouvelles valeurs des paramètres ajustés,nous avons réexaminé l'application de l'approche ECS non-Markovienne (déjà développée pour des spectres de diffusion Raman anisotrope de CO2) _a des spectres de diffusion Raman isotrope, spectre rotationnel pur et spectres ro-vibrationnels de la bande _1 et 2_2. Nous avons également présenté une généralisation de cette approche, aux bandes parallèles et perpendiculaires d'absorption infrarouge, pour les molécules linéaires avec des modes de flexion, accompagnée d'applications au cas de CO2. / Modeling of line mixing in the molecular gas spectra is based on the concept of the relaxation matrix whose diagonal elements describe the isolated lines and non-diagonal elements represent the transfer of intensity between the lines. Thesenon-diagonal elements are modeled by applying scaling laws such as ECS (Energy-Corrected Sudden) model. We considered the CO2 molecule due to its important role in the terrestrial and planetary atmospheres. In addition, because of the small value of the rotational constant, the lines over lap, giving rise to the line-mixing.Using the new values of the tted parameters, we reviewed the application of ECSnon-Markovian (already developed for an isotropic Raman scattering spectra ofCO2) approach to isotropic Raman scattering spectra, rotational spectrum andro-vibrational spectra of 1 and 2 2 band. We also presented a generalization of this approach for the parallel and perpendicular bands of infrared absorption for linear molecules with the bending modes, and their applications for CO2 molecule
37

Sources optiques fibrées pour applications biomédicales / Fiber-based light source for biomedical applications

Hage, Charles-Henri 23 January 2013 (has links)
Ce mémoire présente les travaux effectués sur le développement d'une source optique servant à des applications d'imagerie biomédicale en général et de diffusion Raman cohérente en particulier. En effet la diffusion de ces dernières est freinée par le verrou technologique que constitue la nécessité de deux impulsions synchronisées et décalées en longueur d’onde. La praticité et les possibilités de conversions de fréquences offertes par l’optique non-linéaire fibrée sont ainsi utilisées pour adresser ce verrou technologique. Tout d’abord, une source simplement réglable en longueur d’onde est générée par l’effet d’auto-décalage en fréquence optique d'un soliton par effet Raman. Une étude des principaux paramètres de fibre aboutit à des décalages de 320 à plus de 500 nm, permettant une imagerie des résonances d’intérêt (≈ 1000-4000 cm-1). Deux applications de ce décalage sont présentées. Ensuite, l’autre impulsion voit sa largeur spectrale réduite de 70 à 10 cm-1 par compression spectrale, qui consiste en un "regroupement non-linéaire de fréquences sans pertes", afin de bénéficier de la résolution spectrale nécessaire. Enfin, la source développée est validée par l’acquisition de spectres CARS de différents échantillons de référence, pour différentes résonances (850 à 1750 cm-1). Une extension de la source à d'autres types d'imagerie est proposée, ainsi qu'une architecture de source quasiment entièrement fibrée exploitant les principes développés au cours de cette thèse / This manuscript presents the work done concerning the development of a light source used for biomedical imaging and more particularly for coherent Raman scattering imaging. In fact an efficient broadcasting of these ones is hampered by the need of two synchronized and wavelength shifted pulses. As so, the handiness and frequency conversion capabilities of nonlinear fiber optics are used to circumvent this technological lock. First of all, an easy wavelength tunable source is set by the use of the self-shifting in optical frequency of a soliton. A study of the main fiber parameters lead to shifts of 320 to more than 500 nm which allows interesting molecular resonances imaging (≈ 1000-4000 cm-1). Two applications of this shift are also reported. Then, the second pulse sees its spectral width reduced from 70 to 10 cm-1 by spectral compression, which consists in a "loss-less frequency regrouping", in order to obtain a proper spectral resolution. Finally, the developed source is validated by acquiring CARS spectra of different reference solvents and for different resonances (850 to 1750 cm-1). An evolution of this source to allow other imaging techniques is proposed, as well as a quasi-all-fibered source exploiting the principles addressed during this thesis work
38

Microscopie de mélange à quatre ondes résolue en polarisation pour sonder l’ordre moléculaire dans les milieux biologiques / Polarization resolved four-wave mixing microscopy : a tool to probe molecular order in biological media

Bioud, Fatma Zohra 28 November 2013 (has links)
Nous avons développé une méthodologie basée sur phénomène de mélange à quatre ondre polarimétrique « Four wave Mixing FWM » et son équivalen résonant la diffusion Raman cohérente anti-Stokes (CARS, Coherent Anti-Stokes Raman Scattering) polarimétrique et réalisé des mesures sur des systèmes cristallins, simili biologiques : les membranes cellulaires connues sous le nom de « Multilamellar Vesicles MLV » et des échantillons de biologiques : la myeline, et ce, en variant les polarisations des lasers excitateurs, Pompe et Stokes. Le signal anti-Stokes émis est ensuite analysé afin d’en extraire les ordres 2 et 4 de la fonction de distribution angulaire des molécules actives constituant l’échantillon. Pour cela, plusieurs approches sont explorées telles que des algorithmes d’optimisation ou par décomposition en série de fourrier du signal polarimétrique. Ces multiples approches en traitement du signal permettent d’obtenir de manière rapide les coefficients des fonctions de distribution angulaire recherchées, et ainsi d’avoir des informations sur la symétrie des échantillons imagés, allant jusqu’à l’observation d’une symétrie d’ordre 4. La capacité de la microscopie non linéaire résolue en polarisation à sonder des ordres moléculaires est clairement démontrée et ainsi son intérêt dans l’étude de la relation entre la structure et la fonction de systèmes biologiques. / The capacity to quantify molecular orientational order in tissues is of a great interest since pathologies (skin lesion, neurodegenerative diseases, etc) can induce strong modifications in proteins’ organization. While numerous studies have been undertaken using polarization resolved second order nonlinear optical microscopy which is only specific to non-centrosymmetric organizations, higher order effects have been less explored. Four-wave mixing (FWM) microscopy and its resonant counterpart coherent anti-Stokes Raman scattering (CARS) can be of a great utility as label free diagnosis tools benefiting from less constraining symmetry rules. In this work, we implement incident polarizations tuning in FWM and CARS microscopy to probe molecular order, using a generic method to read-out symmetry information.Fourier analysis of the polarization-resolved FWM/CARS signal processed with an analytical model provides a fast and direct determination of the symmetry orders of the distribution function of the probed molecules. This method does not require a priori knowledge of the organization structure and provides quantitatively its second and fourth order symmetries. We applied this technique on different systems, from crystalline to less organized (multilamellar vesicles and proteins aggregates). We show that this new approach brings additional and more refined information on supra-molecular structures in complex media.
39

Thermographie et mesures de concentrations multi-espèces par diffusion Raman spontanée pour la combustion turbulente / Thermography and multi-species concentrations measurements by spontaneous Raman scattering for turbulent combustion

Ajrouche, Hassan 08 July 2016 (has links)
Les diagnostics lasers ont prouvé leur potentiel pour l'analyse des écoulements et des phénomènes de combustion par la mesure de champs de vitesses, de concentration d'espèces et de température. La diffusion Raman spontanée (DRS) est une des rares méthodes permettant de mesurer la température et la concentration de manière in-situ avec la possibilité de sonder plusieurs espèces simultanément. L'analyse des flammes turbulentes par DRS est difficile en raison de la nécessité de mesures mono-coup avec de fortes résolutions spatiales et temporelles et de la présence de lumière parasite. L'originalité de notre nouveau dispositif de mesure réside dans l'utilisation d'un obturateur électro-optique à base de cellule de Pockels (OCP), permettant d'éliminer les lumières non polarisées de fond de flamme, compatible avec une mesure 1D. Une réduction significative de l'émission de flamme et une amélioration du rapport signal sur bruit des espèces Raman actives ont été obtenues. La capacité de la DRS en tant que méthode de thermométrie mono-coup a été testée avec succès dans le cas d'une flamme de prémélange et de diffusion laminaire fuligineuse. L'écart relatif entre les températures moyennes mesurées dans les gaz brûlés et celles données par la modélisation de flamme est inférieur à 1 %. L'analyse de la thermométrie Raman à basse température a montré qu'une meilleure précision était obtenue avec la modélisation de 02 comparée à celle N2. Par la suite, le potentiel de la DRS à fournir des mesures simultanées de concentrations instantanées de N2, 02 et CO dans les flammes a été validé. Une évaluation des performances de différents détecteurs CCD accompagnés de l'OCP a également été réalisée. Les résultats obtenus avec la BI-CCD et la BI-EMCCD pour la température, le gradient de température et la forte densité sont en bon accord avec les calculs laminaires 1D de flamme adiabatique fournis par COSILAB. La BI-EMCCD a montré qu'elle est le détecteur le plus sensible pour la détection des espèces à faibles concentrations comme le CO. Enfin, des mesures par DRS ont été obtenues dans une flamme-jet de diffusion turbulente, en présence des suies illustrant le potentiel de cette technique pour construire une base de données importante pour la modélisation numérique des flammes / Laser diagnostics have been proven to be an indispensable tool to analyze the flow and combustion phenomena by allowing non-intrusive measurements of the velocity field, concentration and temperature. Spontaneous Raman Scattering (SRS) is one of the few methods providing simultaneously in-situ temperature and multi-species concentrations. Measurement in turbulent flames by SRS is still challenging due to the emission background and the requirement of single-shot measurements with high spatial and temporal resolutions. The originality of the present approach consists in use of a large aperture Pockels cell based electro-optical shutter (PCS), that allows removing unpolarised background flame emission and compatible with a 1D measurement. A significant reduction of flame emission was observed and consequently signal to noise ratio was enhanced. The ability of SRS in terms of thermometric single-shot method was demonstrated successfully in premixed laminar flames and sooty laminar diffusion flames. The measured temperature in burnt gases and those calculated by adiabatic flame modelling was within 1 %. Thermometric Raman analysis for low temperatures demonstrates the reliability of measurements, with a better accuracy for 02 compared to N2. Subsequently, the ability of SRS technique to simultaneously measure instantaneous concentrations of N2, 02 and CO was demonstrated. The ability to measure single-shot scalar values accurately is assessed by comparing different CCD detectors with the PCS. The results obtained from the BI-CCD and the BI-EMCCD concerning temperature, temperature gradient and high density were in good agreement with the COSILAB calculation for 1D laminar adiabatic flame. The BI-EMCCD observed to be the most sensitive in detecting low concentration elements like CO. Finally, SRS technique was applied to a turbulent sooting jet flame, illustrating the potentiel of this technique to build an important database for flame modelling
40

Développement de la spectroscopie DRASC femtoseconde à sonde à dérive de fréquence pour la thermométrie haute cadence dans les milieux gazeux réactifs / Development of the chirped probe pulse femtosecond coherent anti-Stokes Raman scattering for high-speed temperature measurements in gaseous reactive flowfields

Berthillier, Frédéric 19 December 2017 (has links)
L’étude expérimentale des processus physico-chimiques de la combustion nécessite de disposer de diagnostics non-intrusifs. Le présent manuscrit reporte le développement du diagnostic laser de mesure de température DRASC (Diffusion Raman anti-Stokes Cohérente) en régime d’impulsions laser femtoseconde pour lequel la configuration à sonde à dérive de fréquence (CPP) a permis d’effectuer des mesures instantanées de température à 1kHz. Un travail à la fois théorique, numérique et expérimental a permis d’extraire la température des spectres DRASC instantanés acquis dans des mélanges air/argon (300-600K) et en flamme prémélangée CH4/Air avec une précision de l’ordre de 1% à 2100 K. La validité de ces résultats est obtenues par des confrontations numérique/expérimental pour différentes grandeurs d’influence. Cette étude permettra dans un proche futur d’appliquer le diagnostic DRASC fs CPP dans des flammes turbulentes représentatives d’écoulements réels observés en combustion aéronautique. / The experimental study of the physico-chemical processes of combustion requires the use of non-intrusive diagnostics. This manuscript reports the development of the CARS (Coherent Anti-Stokes Raman Scattering)) laser diagnostic in the femtosecond pulse regime for which the Chirped Pulse Probe (CPP) configuration enabled instantaneous measurements of temperature at 1kHz. A theoretical, numerical and experimental study allowed highlighting the possibility to measure temperature from the data processing of instantaneous DRASC spectra acquired in air/argon mixtures (300-600K) and in premixed flame CH4/Air with an accuracy of 1% at 2100 K. Validity of these results was obtained from numerical/experimental confrontations for different scalar parameters configurations. This study would enable in the near future the application of the CPP fs CARS diagnostic in turbulent flames representative of real flows observed in aeronautical combustion.

Page generated in 0.0835 seconds