• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 34
  • 4
  • 4
  • 4
  • 4
  • 4
  • 1
  • 1
  • Tagged with
  • 38
  • 17
  • 10
  • 8
  • 8
  • 8
  • 7
  • 7
  • 7
  • 6
  • 5
  • 5
  • 5
  • 5
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Dispositivo para avaliar a força muscular dos membros superiores

Cortez, Paulo José Oliveira [UNESP] 21 August 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:34Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-08-21Bitstream added on 2014-06-13T18:57:55Z : No. of bitstreams: 1 cortez_pjo_me_guara.pdf: 2510243 bytes, checksum: 26b672349be7c1399c87d0ca359b2271 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Os objetivos do presente trabalho foram o desenvolvimento de um dispositivo capaz de mensurar a força muscular gerada pelos músculos do membro superior e, a verificação do funcionamento e adaptabilidade desse dispositivo, através de um estudo comparativo da força muscular em sujeitos saudáveis. Foi idealizada uma Estação de Medição de Força para avaliar a força muscular dos membros superiores a partir de contrações isométricas na direção vertical (flexão) e horizontal (rotação) contendo transdutores, condicionador de sinais e placa de aquisição de dados e, por fim, um computador. Após a construção e calibração do dispositivo, foi realizado um estudo comparativo da força muscular. Participaram do estudo 22 sujeitos do sexo masculino, com idade de 18 e 19 anos, militares, massa corpórea entre 57,7 e 93 kg (71,8 ± 9,45 kg) e com estatura entre 1,67 e 1,90 m (1,75 ± 0,06 m), saudáveis e sem história clínica de patologia ortopédica ou qualquer tipo de lesão no sistema músculoesquelético. Foram aplicados 3 testes de força: Flexão (sentido vertical), Rotação Interna e Rotação Externa (sentido horizontal). Para cada tipo de esforço foram solicitadas 3 (três) contrações voluntárias máximas por 10 segundos, com intervalo de 30 segundos entre cada contração. Através da análise comparativa dos dados, foi observada semelhança estatística entre as forças geradas pelo membro superior direito e esquerdo. Conclui-se que o dispositivo construído e testado apresenta inúmeras possibilidades para a análise biomecânica. / The aim of this study were the development of a device capable of measuring the muscle strength generated by the muscles of the upper limb and verification of efficiency and adaptability of this device through a comparative study of muscle strength in healthy subjects. It was an idealized Measurement of Force Station, to measure the muscular strength of senior members from isometric contractions in vertical direction (flexion) and horizontal (rotation) containing transducers, signal conditioning and data acquisition card and, finally, a computer. After the construction and calibration of the device it was made a comparative study of muscle strength. Twenty two make people participated in this study , were male, aged 18 and 19 years, military, body mass between 57.7 and 93 kg (71.8 ± 9.45 kg) and height between 1.67 and 1.90 m (1.75 ± 0.06 m), and healthy with no history of clinical orthopedic pathology or any kind of damage to the musculo-skeletal system. It was applied 3 tests of strength: Flexion (vertical direction), internal rotation and lateral rotation (horizontal direction). For each type of effort were required three (3) maximum voluntary contractions for 10 seconds, with an interval of 30 seconds between each contraction. Through analysis of comparative data, was observed statistical similarity between the forces generated by the upper right and left limbs. It was concluded that the device built and tested presents many possibilities for biomechanical analysis.
2

Dispositivo para avaliar a força muscular dos membros superiores /

Cortez, Paulo José Oliveira. January 2008 (has links)
Orientador: José Elias Tomazini / Banca: José Elias Tomazini / Banca: Celso Pinto Moraes Pereira / Banca: Mauro Gonçalves / Resumo: Os objetivos do presente trabalho foram o desenvolvimento de um dispositivo capaz de mensurar a força muscular gerada pelos músculos do membro superior e, a verificação do funcionamento e adaptabilidade desse dispositivo, através de um estudo comparativo da força muscular em sujeitos saudáveis. Foi idealizada uma Estação de Medição de Força para avaliar a força muscular dos membros superiores a partir de contrações isométricas na direção vertical (flexão) e horizontal (rotação) contendo transdutores, condicionador de sinais e placa de aquisição de dados e, por fim, um computador. Após a construção e calibração do dispositivo, foi realizado um estudo comparativo da força muscular. Participaram do estudo 22 sujeitos do sexo masculino, com idade de 18 e 19 anos, militares, massa corpórea entre 57,7 e 93 kg (71,8 ± 9,45 kg) e com estatura entre 1,67 e 1,90 m (1,75 ± 0,06 m), saudáveis e sem história clínica de patologia ortopédica ou qualquer tipo de lesão no sistema músculoesquelético. Foram aplicados 3 testes de força: Flexão (sentido vertical), Rotação Interna e Rotação Externa (sentido horizontal). Para cada tipo de esforço foram solicitadas 3 (três) contrações voluntárias máximas por 10 segundos, com intervalo de 30 segundos entre cada contração. Através da análise comparativa dos dados, foi observada semelhança estatística entre as forças geradas pelo membro superior direito e esquerdo. Conclui-se que o dispositivo construído e testado apresenta inúmeras possibilidades para a análise biomecânica. / Abstract: The aim of this study were the development of a device capable of measuring the muscle strength generated by the muscles of the upper limb and verification of efficiency and adaptability of this device through a comparative study of muscle strength in healthy subjects. It was an idealized Measurement of Force Station, to measure the muscular strength of senior members from isometric contractions in vertical direction (flexion) and horizontal (rotation) containing transducers, signal conditioning and data acquisition card and, finally, a computer. After the construction and calibration of the device it was made a comparative study of muscle strength. Twenty two make people participated in this study , were male, aged 18 and 19 years, military, body mass between 57.7 and 93 kg (71.8 ± 9.45 kg) and height between 1.67 and 1.90 m (1.75 ± 0.06 m), and healthy with no history of clinical orthopedic pathology or any kind of damage to the musculo-skeletal system. It was applied 3 tests of strength: Flexion (vertical direction), internal rotation and lateral rotation (horizontal direction). For each type of effort were required three (3) maximum voluntary contractions for 10 seconds, with an interval of 30 seconds between each contraction. Through analysis of comparative data, was observed statistical similarity between the forces generated by the upper right and left limbs. It was concluded that the device built and tested presents many possibilities for biomechanical analysis. / Mestre
3

Desenvolvimento de um dinamometro para determinação de duas componentes da força de usinagem no processo de retificação plana tangencial

Carvalho, Jose Francisco Ribeiro 14 July 2018 (has links)
Orientador : Dino Ferraresi / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Campinas / Made available in DSpace on 2018-07-14T22:46:20Z (GMT). No. of bitstreams: 1 Carvalho_JoseFranciscoRibeiro_M.pdf: 2191818 bytes, checksum: 702223447f56aabf95fc231db1b54a43 (MD5) Previous issue date: 1976 / Resumo: : Estuda-se inicialmente as características de trabalho. Discutem-se o projeto, construção, aferição e ensaios de um dinamômetro para medida de duas componentes da força de usinagem, com elementos de deformação à base de lâminas. Estudo analítico das solicitações nas lâminas. Medida de forças até 50 kgf, através de extensômetros elétricos. Inexistência de interferência de uma direção, em outra. Comenta-se o estudo estatístico, curvas de aferição, comportamento estático e dinâmico. Frequência natural do dinamômetro em tôrno de 1000 HZ. Comenta-se o procedimento experimental, registros de forças pàra algumas condições de usinagem, comportamento do dinamômetro, considerações e conclusões finais / Abstract: The publication deals initially with metal workirig characteristics. Design, constrution and analysis of a special force transducer developed to independently measureforçes in two directions in metal grinding are described. Beams under bending with aplied strain-gages constitute the measuring elements for forces up to 50kgf . The analytical solution for the problem of the beam solicitation is also shown. Inexistence of iriterference from one component on the other. Statistic investigation, gaging curves, static and dynamic test's procedure are commented. Natural frequency of the dynamometer about 1000HZ. Experimental procedure, record of the forces for some machining conditions, dynamometer performance, considerations and conclusion are shown / Mestrado / Mestre em Engenharia Mecânica
4

Estudo eletromiografico dos musculos biceps femoral (cabeça longa), semitendineo e semimembranaceo na contração isometrica voluntaria maxima em 30, 60 e 90 graus de flexão da perna, com e sem o uso de bandagem funcional

Cerveny, Gislaine C. O 22 November 2001 (has links)
Orientador : Fausto Berzin / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-31T20:03:22Z (GMT). No. of bitstreams: 1 Cerveny_GislaineC.O_D.pdf: 8051312 bytes, checksum: 9a2c23b0daad7927ee1ba26457e02c74 (MD5) Previous issue date: 2001 / Resumo: O objetivo deste estudo foi o de verificar o efeito de uma técnica de bandagem funcional, na atividade elétrica e força dos Mm. bíceps femoral (Cabeça longa), semitendíneo e semimembranáceo, no membro inferior direito (membro dominante) de 12 voluntárias, sem histórias de distúrbios osteoarticulares e/ou musculares da região do joelho, com faixa etária variando de 21 a 26 anos (X = 23,08 ::I:: 2,24) e índice de massa corpórea no padrão da normalidade. A coleta dos sinais eletromiográficos foi realizada durante a contração isométrica voluntária máxima em 30, 60 e 90 graus de flexão da perna, de três maneiras: sem bandagem, com a bandagem aplicada na forma proposta por KAZEMI (1997), e com a bandagem frouxa. A técnica consistiu na colocação de bandagem rígida de 5 cm (Smith+Nephew@), a partir da aplicação de uma "almofada" feita com mousse de proteção na região medial posterior da coxa, no ponto médio entre o sulco infraglúteo e o eletrodo de superfície do M. semitendíneo. A bandagem era então fixada, tracionada lateralmente e para baixo, fixando-a no sentido transversal, de modo a promover uma força centrípeta em toda a circunferência da coxa. Os sinais foram captados por um módulo condicionador de sinais com conversão analógica-digital. A aquisição e o armazenamento dos dados em arquivo, se deram por meio do aplicativo AqDados@, versão 4.18 para MS-DOS (Lynx@). O software utilizado para o processamento e análise dos dados foi o Matlab@ (versão 5.0). Para a análise estatística dos dados utilizou-se o sistema computacional Statistical Analysis System. Estudou-se a suposição de normalidade dos dados através do teste de Shapiro- Wilk e como os conjuntos de dados experimentais para todas as variáveis consideradas não apresentaram evidências estatísticas para aceitar a suposição de normalidade, analisou-se cada uma das variáveis através do teste não-paramétrico de Kruskal-Wallis. Para todas as análises de variância considerou-se o nível crítico de 5% (p<o, 05). As variáveis analisadas foram a densidade espectral de potência e a envoltória não normalizada com base nos diferentes músculos, angulações e tratamentos aplicados. Diante dos resultados obtidos conclui-se que: O recrutamento de unidades motoras em 30° e 60° de flexão da perna foi maior no M. semimembranáceo em comparação ao M. semitendíneo e dos dois em relação ao M. bíceps femoral (Cabeça longa); a bandagem foi efetiva no aumento dos valores da amplitude do sinal eletromiográfico em relação ao tempo (envoltória não normalizada) do M. bíceps femoral em 90° de flexão da perna, em comparação à condição da bandagem frouxa e sem a bandagem; o M. semimembranáceo, na situação sem bandagem, apresentou valores para a envoltória não normalizada menores à medida em que o ângulo de flexão da perna aumentou sendo a bandagem efetiva aos 60° e 90°, visto que os valores foram maiores nestas angulações; a bandagem foi eficaz e a bandagem frouxa promoveu efeito placebo positivo nos valores da envoltória não normalizada do M. semitendíneo em comparação com a situação sem bandagem; a bandagem produz melhores resultados em situações de menor alavanca dos segmentos envolvidos; a bandagem frouxa teve efeito placebo positivo nos músculos estudados nos ângulos de flexão da perna que estes tendem a apresentar menor atividade; a força dos músculos flexores é maior na medida em que a angulação de flexão da perna é menor e estes estão mais distendidos; a bandagem foi eficaz e a bandagem frouxa teve efeito placebo positivo no aumento da força dos músculos nos ângulos de 60° e 90° de flexão da perna / Abstract: The purpose of this study was to determine the effect of a functional bandage technique on the electric activity and strength of the biceps femoris (long head), semitendinous and semimembranosus, of the right lower member (dominant limb) of 12 volunteers without any previous injuries ofthe knee, aged between 21 the 26 years old (23,08 X =::1:: 2,24) and body mass index within the standard normality. The electromyographic signs were collected during the maximum voluntary isometric contraction at 30, 60 and 90 degrees of knee flexion, in three ways: without bandage, with the bandage applied in the form proposed by KAZEMI (1997), and with the loose bandage. The technique consisted to apply a rigid bandage with 5 cm width (Smith+Nephew@), from the application of a little cushion made with mousse of protection in the posterior medial region of the thigh, in the average point between the infragluteous wrinkie and the surface electrode of the semitendinous muscle. The bandage was then fixed, pulled laterally and down, fixing it in the transversal direction, in order to promote a centripetal force in all the circumference of the thigh. The signs were registered by a conditioning module of signs with analog-digital conversion. The acquisition and storage of the data in the file were done by means of the applicatory AqDados@, version 4.18 for MS-dos (Lynx@). The software used for the processing and analysis of the data was the Matlab@ (version 5.0). The computational system Statistical Analysis System was used for the statistical analysis of the data. The supposition of normality of the data was studied through the Shapiro- Wilk test. Since the sets of experimental data for all the considered variables did not show statistical evidences supporting the normality assumption, each variable was analyzed through the non-parametric Kruskal- Wallis testo The critical level of 5% was considered (p<0,05) for all the variance analyses. The analyzed variables were the spectral density of strength and the non-normalized covering on the basis of the different muscles, angles and applied treatments. Based on the results obtained it can be concluded that: the recruitment of the motor units at 30° and 60° of knee flexion was bigger in the semimembranosus muscle as compared to the semitendinous muscle, and in both as compared to the biceps femoris (long head) muscle; the bandage was effective in the increase of the values of the amplitude of electromyographic sign in relation to the time (non normalized covering) of the biceps femoris at 90° of knee flexion, as compared to the condition of the loose bandage and without the bandage; the semimembranosus muscle in the situation without any bandage showed values for the non-normalized covering gradually smaller as the angle of the flexion of the leg increased, the bandage being effective at 60° and 90°, since the values were bigger at these angles; the bandage was effective and the loose bandage had positive placebo effect for the values of non-normalized covering of the semitendinous muscle in comparison to the situation without bandage; the bandage produces better results in situations of smaller lever of the segments involved; the loose bandage had positive placebo effect on the studied muscles in angles of the flexion of the leg that these muscles tend to show less activity; the force of the flexor muscles is bigger as the angle of the flexion of the leg is smaller and these muscles are more distended; the bandage was effective and the loose bandage had positive placebo effect in increase the muscle strength at 60° e 90° of the flexion of the leg / Doutorado / Doutor em Biologia Buco-Dental
5

Análise comparativa da atividade muscular do flexor superficial dos dedos e força de preensão palmar em atividades laborativas de uma indústria /

Rodrigues, Daniel Érico. January 2014 (has links)
Orientador: José Elias Tomazini / Banca: Marcelo Sampaio Martins / Banca: Elaine Cristina Martinez Teodoro / Resumo : O presente trabalho teve como objetivo desenvolver um dispositivo capaz de mensurar a força de preensão palmar de forma dinâmica e, a verificação do funcionamento e adaptabilidade desse dispositivo, através de um estudo comparativo da força e a atividade muscular por meio da Eletromiografia do Flexor Superficial dos Dedos em sujeitos saudáveis em uma atividade laborativa de grampeação em uma empresa do ramo automotivo. Para isso o estudo idealizou um Dispositivo de Mensuração da Força de Preensão Palmar contendo extensômetros para avaliar a força muscular de preensão palmar a partir da reprodução de movimentos de grampeação. Participaram do estudo 7 sujeitos do sexo masculino, com idade entre 20 a 30 anos, massa corpórea entre 55 e 80 kg (77,39 ± 13,46 kg) e com estatura entre 1,65 e 1,75 m (1,71 ± 0,03 m), saudáveis e sem história clínica de patologia ortopédica ou qualquer tipo de lesão no sistema musculoesquelético. Foram realizadas 3 coletas simulando o movimento de grampeação. Através da análise comparativa dos dados, não foi observada diferença estatística intrasujeitos entre as forças de preensão e o RMS em cada coleta. Conclui-se que o dispositivo construído e testado apresenta possibilidades de mensuração de parâmetros quantitativos e que possa ser direcionado a novos estudos ergonômicos e biomecânicos / Abstract: This study aimed to develop a device capable of measuring handgrip strength dynamically and verification of operation and adaptability of this device, through a comparative study of strength and muscle activity through electromyography Flexor Superficial fingers in healthy subjects in a work activity of bolting in a automotive company. For this study devised a Device for Measuring Force Gripping Palmar containing gages to evaluate muscle grip strength from playing movements stapling. The study included seven male subjects, aged 20 to 30 years, body mass index between 55 and 80 kg (77.39 ± 13.46 kg) and height between 1.65 and 1.75 m (1.71 ± 0.03 m), healthy with no history of orthopedic disease or any type of injury in the musculoskeletal system. Three collections were performed simulating the motion stitching. Through comparative analysis of the data, no statistical difference between intrasubjectives forces hold and RMS in each collection was observed. It is concluded that the device has built and tested possibilities of quantitative measurement of parameters and the new ergonomic and biomechanical studies can be directed / Mestre
6

Estudo introdutório e desenvolvimento experimental de sistemas automatizados para exercícios terapêuticos e esportivos

Saldías, Daniel Alejandro Ponce January 2009 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Mecânica, Florianópolis, 2009 / Made available in DSpace on 2012-10-24T14:36:40Z (GMT). No. of bitstreams: 0 / Os dinamômetros isocinéticos têm uma grande participação na área médica, da fisioterapia, e esportiva. Estes equipamentos permitem a avaliação, reabilitação e treinamento muscular mediante o monitoramento contínuo do esforço realizado pelo paciente/esportista para vários tipos de exercícios. O exercício e avaliação isocinética se destaca pela qualidade e quantidade de informações que fornece. Estas informações permitem ao fisioterapeuta diagnosticar com exatidão lesões musculares e determinar o plano de recuperação do paciente. Este trabalho se preocupa em demonstrar as utilidades e princípios de funcionamento dos dinamômetros isocinéticos. Levantam-se críticas dos atuais dinamômetros isocinéticos e se propõem alterações projetivas que poderiam reduzir o custo fixo do equipamento. Para assimilar a tecnologia necessária para a realização de exercícios mediante equipamentos automatizados, é desenvolvido um protótipo básico de sistemas automatizados para exercícios terapêuticos e esportivos. Este protótipo, designado como "SMTE", é projetado mediante o processo de desenvolvimento de produto.
7

Análise comparativa da atividade muscular do flexor superficial dos dedos e força de preensão palmar em atividades laborativas de uma indústria

Rodrigues, Daniel Érico [UNESP] 31 July 2014 (has links) (PDF)
Made available in DSpace on 2014-12-02T11:16:52Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-07-31Bitstream added on 2014-12-02T11:21:17Z : No. of bitstreams: 1 000798713.pdf: 1962363 bytes, checksum: 87be5eeb20767bd37130fc408150897e (MD5) / O presente trabalho teve como objetivo desenvolver um dispositivo capaz de mensurar a força de preensão palmar de forma dinâmica e, a verificação do funcionamento e adaptabilidade desse dispositivo, através de um estudo comparativo da força e a atividade muscular por meio da Eletromiografia do Flexor Superficial dos Dedos em sujeitos saudáveis em uma atividade laborativa de grampeação em uma empresa do ramo automotivo. Para isso o estudo idealizou um Dispositivo de Mensuração da Força de Preensão Palmar contendo extensômetros para avaliar a força muscular de preensão palmar a partir da reprodução de movimentos de grampeação. Participaram do estudo 7 sujeitos do sexo masculino, com idade entre 20 a 30 anos, massa corpórea entre 55 e 80 kg (77,39 ± 13,46 kg) e com estatura entre 1,65 e 1,75 m (1,71 ± 0,03 m), saudáveis e sem história clínica de patologia ortopédica ou qualquer tipo de lesão no sistema musculoesquelético. Foram realizadas 3 coletas simulando o movimento de grampeação. Através da análise comparativa dos dados, não foi observada diferença estatística intrasujeitos entre as forças de preensão e o RMS em cada coleta. Conclui-se que o dispositivo construído e testado apresenta possibilidades de mensuração de parâmetros quantitativos e que possa ser direcionado a novos estudos ergonômicos e biomecânicos / This study aimed to develop a device capable of measuring handgrip strength dynamically and verification of operation and adaptability of this device, through a comparative study of strength and muscle activity through electromyography Flexor Superficial fingers in healthy subjects in a work activity of bolting in a automotive company. For this study devised a Device for Measuring Force Gripping Palmar containing gages to evaluate muscle grip strength from playing movements stapling. The study included seven male subjects, aged 20 to 30 years, body mass index between 55 and 80 kg (77.39 ± 13.46 kg) and height between 1.65 and 1.75 m (1.71 ± 0.03 m), healthy with no history of orthopedic disease or any type of injury in the musculoskeletal system. Three collections were performed simulating the motion stitching. Through comparative analysis of the data, no statistical difference between intrasubjectives forces hold and RMS in each collection was observed. It is concluded that the device has built and tested possibilities of quantitative measurement of parameters and the new ergonomic and biomechanical studies can be directed
8

Teste de preensão isometrica da mão: metodologia e implicações fisiologicas

Novo Junior, Jose Marques 27 March 1998 (has links)
Orientadores: Lourenço Gallo Junior, Alberto Cliquet Junior / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-07-23T15:26:29Z (GMT). No. of bitstreams: 1 NovoJunior_JoseMarques_D.pdf: 4195338 bytes, checksum: 67841d221106de2079e71eedf5fb69d6 (MD5) Previous issue date: 1998 / Resumo: o propósito deste estudo foi explorar as possibilidadesde futuras aplicações das curvas força-tempo nos testes de preensão isométrica da mão. Uma análise qualitativa da força total e das forças individuais dos dedos e das relações com alguns fatores fisiológicos, tais como fadiga e frequência cardíaca, são relatadas. É descrito o desenvolvimento de um instrumento controlado por microcomputador, o qual possibilita a identificação das forças dos dedos simultaneamente, durante apreensão exercida numa empunhadura anatõmica. Esta última, acoplada a dispositivos hidráulicos instrumentados com sensores de pressão, viabiliza a medição da força. Num primeiro momento, participaram 100 sujeitos normais que realizaram o teste de preensão com o dinamõmetro Jamar para efeitos de comparação. No laboratório, quatro voluntários foram avaliados tendo estimulação visual e verbal durante o esforço. Antes dos testes, foram submetidos a exercícios de aquecimento. Durante as medições, o eletrocardiograma foi registrado. Os testes foram executados em contrações voluntárias máximas, com a mão dominante. Foi observado o decréscimo da força ao longo do teste (fadiga), o aumento da frequência cardíaca em um sujeito, e as contribuições dos dedos. Para todos os voluntários os dedos indicador e médio apresentaram uma parcela de contribuição maior. Emalguns casos não se verificou a ação do dedo mínimo. Os procedimentos acima relatados estabelecem a base para uma metodologia que auxilie o terapeuta na avaliação da severidade de uma patologia, como também o acompanhamento da recuperação de um paciente após um tratamento. A metodologia seria útil também na pesquisa sobre estimulação elétrica neuromuscular em indivíduos tetraplégicos e na avaliação e diagnóstico das doenças ocupacionais / Abstract: The purpose of this work is to explore the possibilities for further applications of the force-time curves in the handgrip tests. A qualitative analysis of total and finger forces and their relationship with some physiological factors, such as fatigue and heart rate, are reported. A microcomputer-controlled instrument which measures forces of ali four fingers forces simultaneously, in a single attempt at squeezing an anatomic handle, is described. The handle, linked to four hydraulic devices instrumented with pressure sensors, provides the force measurement. In a first esperiment, 130 normal subjects exerted their handgrip on the Jamar dynamometer as a basis for comparative data. In a laboratory set, four individuais were tested under visual and verbal stimulation. Prior the tests each one was submitted to tlexibility exercises. During isometric hand-dynamometry the ECG signal was recorded. The tests were performed at maximum voluntary contraction with the dominant hand. The decrease of force along the test (fatigue), the increase in heart rate owing isometrid eftort in one subject, and the contributions of the fingers were observed. For ali subjects, the index and middle fingers contributed more to the total grasp force. In some cases the little finger had no participation. The above assessment procedure provides baseline methodology which could serve as guidelines to a clynician in assessing the severity of the disease and observing the patient's recovery following the treatment. It would also be useful in the research on neuromuscular electrical stimulation in quadriplegic patients and on screening and diagnosis of occupational diseases / Doutorado / Automação / Doutor em Engenharia Biomédica
9

Análise do equilíbrio dinâmico do membro inferior em uma situação de instabilidade provocada pela prancha de equilíbrio e tênis instáveis /

Silva, Glauce Gonzaga. January 2014 (has links)
Orientador: Tamotsu Hirata / Banca: José Elias Tomazini / Banca: Marcelo Sampaio Martins / Banca: Elaine Cristina Martinez Teodoro / Banca: Jayme Pereira de Gouvêia / Resumo: O equilíbrio corporal é um evento dinâmico que está diretamente relacionado à independência funcional do indivíduo. O objetivo do presente estudo foi investigar a influência de diferentes tipos de calçados e da imobilização da articulação do tornozelo sobreos componentesbiomecânicos do equilíbrio dinâmico.Doze mulheres saudáveis (idade: 27,08± 4,79 anos,IMC: 22,58 ± 2,17 kg/m2) foram analisadas durante uma tarefa de oscilação corporal ântero-posterior sobre umaprancha de equilíbrio em quatro condições: descalças, usando tênis habitual, usando tênis instáveis e com o tornozelo dominante imobilizado em 50% de sua total amplitude de movimento. As análises consistiram em duasetapas: realização da contração voluntária máxima (CVM), condição estática, e oscilação livre, condição dinâmica.Uma plataforma de força foi posicionada sobrea prancha deequilíbrio para avaliar as distribuições das forças de reação. A análise cinemática tridimensional foi realizada para avaliar as oscilações daprancha, do centrode massa edos ângulos articulares do tornozelo. Foi realizadaanálise eletromiográficados músculos reto femoral, tibial anterior,gastrocnêmio medial e lateral do membro dominante. Os valores foram comparados por análise de variância one way e teste T pareado(p<0,10). A análise dinamométrica revelou maior força vertical dereação do solo durante a oscilação anteriorem relaçãoà posterior (p< 0,001). A condição de imobilização foi significativamente maior em relação às demais (p=0,049 para todas). Na análise cinemática, maior ângulo de inclinação da prancha durante a oscilação posterior foi observado (p=0,001). A análise eletromiográfica revelou maior ativação na condição de imobilização (p = 0,08). A maior amplitude de oscilação anterior em relação à posterior ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Body balance is a dynamic event that is directly related to the functional independence of individual. Thepurpose of this study was to investigate the influenceof different typesof shoes and immobilization of the ankle joint on the mechanical componentsof dynamic equilibrium. Twelve healthy women(age: 27.08 ± 4.79 years;BMI: 22.58 ± 2.17 kg/m2) wereanalyzed duringa task anteroposterior body sway on a balanceboard for four conditions: barefoot, with a regular tennis, with an unstable shoes andwith dominant ankle immobilized at 50% of itsfull range of motion. Analysisconsistedof two steps: achievement of maximumvoluntary contraction (MVC), static condition, andfree oscillation, dynamiccondition. One force platformwas properly positioned on the balance board to evaluate the distributions of the reaction forces. Three-dimensional kinematic analysis was performedto evaluate the fluctuationsof the mass center. Electromyographic analysis of therectus femoris,tibialis anterior, medial and lateralgastrocnemius of thedominant limb was performed. Values were compared by one way variance analysis and pared t-test (p<0,10).Dinamometricanalysis showed greater vertical ground reaction force during theanterior body away compared to posteriorbody away (p<0,001). Immobilization condition was significantly higher compared to all conditions (p=0.049 for all). In kinematic analysis, a greater angle of inclination of the board during the posterior body away was observed (p=0,001). Higher activation in immobilization condition was observed in relation to other (p=0,08). Equality of electromyographic values of other muscles investigated was due the co-contraction performed during the oscillations. The largest amplitude of anterior body away compared to the posterior oscillation reflects better conditions fall protection in immobilization condition. Ankle and hip strategies were activated of effective ... (Complete abstract click eletronic access below) / Doutor
10

Implementação de um sistema de aquisição de dados da técnica de judô Osotogari utilizando dummy na realização do uchikomi /

Nagata, Eduardo Yoshinori. January 2015 (has links)
Orientador: Tamotsu Hirata / Banca: José Elias Tomazini / Banca: Marcelo Sampaio Martins / Banca: Cesar Ferreira Amorim / Banca: Luiz Heleno Moreira Duque / Resumo: O judô é um esporte muito praticado no mundo todo, sendo uma modalidade que exige boa condição física para a melhor performance. Para a execução dos golpes é necessária a coordenação das ações dos membros superiores e inferiores, assim como a força exercida pelos membros ser sincronizada para atingir eficiência no gesto motor. O presente estudo teve por objetivo construir um equipamento de avaliação de desempenho para verificar o comportamento dos sinais de força na execução da técnica de judô Osotogari no treinamento de uchikomi. O equipamento de avaliação de desempenho confeccionado com 4 células de carga que foram posicionados nos 4 contatos do uke (pessoa que recebe o golpe) no tori (pessoa que executa o golpe) ao realizar o golpe. O equipamento foi construído num dummy com uma célula de carga acoplada no peito esquerdo, outra célula de carga posicionada na parte posterior da coxa direita. O dummy foi vestido com um kimono adaptado, e nele foram colocados uma célula de carga na manga direita e outra célula de carga na gola esquerda. Participaram da pesquisa 12 sujeitos com dominância lateral direita, sendo 5 experientes e 7 iniciantes. Os sujeitos realizaram 1 série de 10 repetições do Osotogari. Verificou-se diferença significativa (p < 0,05) entre os sujeitos experientes e iniciantes nos valores de força da célula de manga e célula de gola. Os valores de força da célula da perna e célula do peito não apresentaram diferença significativa. Foi observado média correlação linear entre os valores de pico da força da célula de manga e de gola, que pode ser explicado pelo sincronismo temporal e ritmo que é empregado pelas duas mãos. Foi verificado que há um instante ideal para aplicar a força para se obter um melhor desempenho na execução do golpe. A utilização do dummy tem o intuito de suprir a ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Judo is a worldwide practiced sport which requires physical fitness for better performance. For the fulfilment of the techniques, it is necessary the coordination of lower and inferior limbs, as well as the synchronization of power delivered by the limbs to achieve efficiency on the gesture. The objective of the present study was to develop an equipment for the performance evaluation of the judo technique Osotogari during uchikomi training, through the behavior of strength signals. The device had 4 load cells placed on four locations of the uke's body (one who receives the technique) on the tori (one who performs the technique) while applying the technique. The device as built based on a dummy, with one load cell placed on the left side of the chest, other on the back side of the right thigh. The dummy was dressed in a adapted kimono, that received a load cell on the right sleeve and another one on the left side collar. 12 subjects of right side dominance took part on the survey, 7 of them were beginners and 5 were experienced. Each of these subjects performed 1 serie of 10 repetitions of Osotogari. A significant difference was observed between experienced subjects and beginners for the sleeve and the collar load cells data. In the other hand, no significant difference was observed on the chest and thigh load cells. Moderate linear correlation was observed between peak force data of the sleeve and collar load cells, which can be explained by the hands' temporal synchronization and rhythm. It was observed that there is an ideal moment to apply strength when performing the technique, in order to achieve better performance. The dummy is intended to meet the need for more practical performance analysis methods, contributing this way to the advance in athletes training / Doutor

Page generated in 0.0728 seconds