• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1119
  • 253
  • 51
  • 21
  • 18
  • 18
  • 18
  • 14
  • 6
  • 4
  • 3
  • 3
  • 3
  • 2
  • 1
  • Tagged with
  • 1450
  • 531
  • 204
  • 194
  • 152
  • 143
  • 141
  • 115
  • 115
  • 115
  • 115
  • 115
  • 110
  • 102
  • 99
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Avaliação clinica do uso do dispositivo intra-uterino T-Cu 200B em adolescentes

Ribeiro, Gizelda Nogueira de Oliveira, 1943- 22 July 2018 (has links)
Orientadores: Abraham Juan Antonio Diaz Moraguez, Luis Bahamondes / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-07-22T23:47:34Z (GMT). No. of bitstreams: 1 Ribeiro_GizeldaNogueiradeOliveira_D.pdf: 1446840 bytes, checksum: 3b0c4ab8a4d34e8715975f3e8c0f5b0e (MD5) Previous issue date: 1997 / Resumo: O objetivo do presente estudo foi avaliar o desempenho do OIU T Cu 200B em mulheres menores de 20 anos de idade que tinham tido pelo menos um filho, comparado com o desempenho em mulheres com dez anos a mais de idade. O grupo de estudo foi constituído por 1.248 mulheres que receberam um DI U T -Cu 200B e que tinham menos de 20 anos no momento da inserção. Para formar o grupo-controle, cada mulher do grupo de estudo foi comparada a outra mulher com dez anos a mais de idade e com a mesma paridade. Ambos os grupos foram acompanhados por quatro anos depois da inserção. O desempenho foi avaliado pelo método de tabela de vida e as diferenças entre os grupos foram testadas pelo método de log-ranl<. Gravidez, expulsão e extração por dor e/ou hemorragia foram significativamente mais freqüentes no grupo de mulheres mais jovens e a taxa de continuação foi mais baixa no mesmo grupo. As taxas de extração por infecção foram baixas em ambos os grupos (taxa acumulada a quatro anos de 2/100 mulheres). A principal conclusão foi que as usuárias do OIU T-Cu 200B com menos de 20 anos tiveram taxas de fracasso maiores e mais expulsões e extrações que as mulheres com dez anos a mais de idade. Entretanto, a taxa de falha com DIU nas mulheres mais jovens foi similar ou menor que a observada com outros métodos reversíveis em adolescentes. A taxa de continuação também foi mais alta no grupo de estudo que a habitualmente observada em adolescentes com outros métodos. Concluiu-se que o DIU T-Cu 2008 não deve ser contra-indicado em mulheres com menos de 20 anos que já tiveram pelo menos um filho, desde que o processo de seleção, a técnica de inserção e o acompanhamento sejam adequados / Abstract: The objective of the study was to evaluate the clinical performance of the T-Cu 2008 IUD in women under 20 years old, having had at least one child, compared to women ten years older. The study group was constituted by 1.248 women who received a T -Cu 2008 and had less than 20 years old at insertion. To constitute the control group every woman of the study group was paired with a woman 10 years older at insertion and having the same parity. 80th groups were followed for four years afie r the insertion. Performance was evaluated by life table analysis and the differences between the groups were tested by the log-rank method. Pregnancy, expulsion, ánd removal for bleeding and or pain were significantly higher in the group of young women and continuation rate was lower in the same group. Rates of removal for infection were low in both groups (cumulative rate of 2% at four years). The main conclusion was that T Cu 2008 IUD users under 20 years old hàd higher failure rate and more expulsions and removals than women ten years older. However, failure rate with IUD in the group of women under 20 years, was similar or better than the rates observed with other reversible methods in adolescents. Continuation rate in the study group was also higher than the one usually observed in adolescents with other methods. Therefore we concluded that the Copper IUD should not be contraindicated in women under 20 years old who have had at least one child, provided a good selection procedure is used, the insertion technique is appropriate, and adequate follow-up is available / Doutorado / Tocoginecologia / Doutor em Medicina
22

Projeto de uma celula de carga para aplicação em suspensões veiculares

Napolitano, Flavio 29 February 2000 (has links)
Orientador: Robson Pederiva / Dissertação (mestrado) - Universidade Estadual de Campinas. Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-07-27T04:58:54Z (GMT). No. of bitstreams: 1 Napolitano_Flavio_M.pdf: 6939786 bytes, checksum: fac37a8262e23e973d8467ffb9b189a8 (MD5) Previous issue date: 2000 / Resumo: Este trabalho apresenta o projeto de uma célula de carga para aplicação em suspensões veiculares, parte integrante de um Dispositivo Automático de Pesagem - DAP. O projeto desta célula de carga foi concebido a partir da teoria de flexão de placas circulares carregadas simetricamente com relação ao centro. Consequentemente, obtiveram-se as equações de tensões máximas no centro da placa e suas direções principais, que foram utilizadas no cálculo da geometria da célula de carga. Fez-se um projeto inicial da célula de carga, sem o efeito do assento esférico da região de aplicação da força, utilizando-se os conceitos teóricos e comparando os resultados com os obtidos pelo programa ANSYS. O projeto :final inclui o efeito do assento esférico, sendo que as diferenças entre os resultados da análise experimental e modelagem numérica confirmaram a correta escolha da geometria da célula de carga. Finalmente, fez-se um estudo da célula de carga trabalhando com uma força aplicada com pequenos desvios em relação à direção nominal, possibilidade mais próxima da realidade para aplicação em veículos / Abstract: The project of the load cell for application in vehicular suspension, as a part of an Automatic Weighting System is presented. The project of this load cell was conceived trom bending theory of circular plate loaded symmetrically related with the center. Consequently were obtained the equations of maximum tensions in the center of the plate, and the principal directions that was used to determine the load cell's geometry. The initial project of the load cell was done without the spherical angel effect, region of load application. It was used theoretical concepts and compared the results with the others obtained by ANSYS programme. In the final project was inc1uded the spherical angel effect. The difference between experimental analyze and numerical modeling confirm the right chose of the load cell's geometry. Finally, it was studied the load cell working with load applied with small diversion related with the nominal direction. This is the nearest possibility to the reality in vehicle application / Mestrado / Mecanica dos Sólidos e Projeto Mecanico / Mestre em Engenharia Mecânica
23

Escalonamento das transferencias de dados entre PLC'S no nivel de celulas no ambiente industrial

Haye Bardina, Juan Antonio 26 February 2004 (has links)
Orientador: Mauricio Ferreira Magalhães / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-04T00:12:24Z (GMT). No. of bitstreams: 1 HayeBardina_JuanAntonio_M.pdf: 464696 bytes, checksum: 7cea867d254c06ec819588aef8442f2a (MD5) Previous issue date: 2004 / Resumo: Este trabalho tem como objetivo apresentar uma metodologia para determinar a utilização do limite da Taxa Monotônica nas transferências entre dispositivos no nível de célula numa área industrial. Foi usado o protocolo de rede padrão IEEE 802.3 por vários motivos, entre os quais podemos mencionar: largura de banda, desenvolvimento dos dispositivos como comutadores e repetidores, baixo custo e taxas de transmissão de 10, 100, 1000 Mb/seg (em estudo 10Gb/seg). Nos PLC's foi feito um estudo dos tempos para a geração e transferência dos dados / Abstract: This work presents a methodology to determine the utilization of the limit of Rate Monotonic on the data transfer among devices in cell level in industrial process. The IEEE 802.3 standard network protocol was used for various reasons like as: bandwidth; device development such as switches and repeaters; low cost and transmission bit rates of 10, 100, 1000 Mb/sec (10 Gb/sec is in study). Times for data generation and transfer inside the PLC¿s were studied. / Mestrado / Automação / Mestre em Engenharia Elétrica
24

SOASim : simulador do controle dinamico de ganho em amplificadores opticos a semicondutor, incluindo validação experimental e aplicações

Gallep, Cristiano de Mello, 1974- 08 May 1999 (has links)
Orientador: Evandro Conforti / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-07-25T00:00:03Z (GMT). No. of bitstreams: 1 Gallep_CristianodeMello_M.pdf: 6529137 bytes, checksum: 7370f871095bc12c86cbfef907807d6f (MD5) Previous issue date: 1999 / Resumo: Apresenta-se o SOA Sim, programa de simulação para amplificadores ópticos a semicondutor (SOA) com controle dinâmico de ganho. Tal programa foi escrito em linguagem C++ utilizando-se de ambiente com interface amigável. São descritos o modelamento matemático utilizado e sua implementação computacional. Resultados de simulação referentes a cascatas de SOAs operados em regime de saturação profunda, com modulação da corrente injetada no SOA e a operação com controle dinâmico de ganho são apresentados em conjunto com resultados experimentais correspondentes, observando-se boa concordância. Resultados exclusivamente teóricos também são apresentados, mostrando as capacidades de regeneração/apagamento do sinal óptico desse tipo de configuração do SOA. Devido, porém, ao tempo de vida finito dos portadores elétricos, essa funções ficam limitadas a taxas médias de transmissão(~1Gb/s) / Abstract: The SOAs Sim, a semiconductor optical amplifier (SOA) with feed-forward gain (FFG) control simulation program, is presented. Such program was written in C++ computer language, using an environment with friedly interfaces. The mathematical model and its implementation are described. Simulation results of deep-saturated cascaded SOAs, with modulated injected current and operations with FFG control are presented, with good agreement with their respective experimental results. Exclusive theoretical results are presented too, showing the capabilities of optical signal regeneration/erasing with this kind of SOA configuration. However, the finite electronic carrier lifetime limits those functions to middle bit rates (~1Gb/s) / Mestrado / Eletronica e Comunicações / Mestre em Engenharia Elétrica
25

Aplicação da técnica de recozimento com solução de Ga-Sn-As ao processamento de F.E.Ts em GaAs dopado por implantação iônica

Oliveira, Rogerio C. de 09 August 1989 (has links)
Orientador: Francisco C. Prince / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin / Made available in DSpace on 2018-07-14T00:00:08Z (GMT). No. of bitstreams: 1 Oliveira_RogerioC.de_M.pdf: 9899732 bytes, checksum: bc7bd394357f8aeb99ceca962bef9b24 (MD5) Previous issue date: 1989 / Resuma: Não informado / Abstract: Not informed. / Mestrado / Física / Mestre em Física
26

Estudos dos fatores que influenciam o desempenho clinico do DIU TCU-200B

Bueno, Jose Geraldo Romanello 14 July 2018 (has links)
Orientadores: João Luiz Pinto e Silva, Abrahan Juan Diaz Moraguez / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-07-14T00:17:18Z (GMT). No. of bitstreams: 1 Bueno_JoseGeraldoRomanello_M.pdf: 1350044 bytes, checksum: 7c153cd509caab42db87e88f1daaa8ff (MD5) Previous issue date: 1989 / Resumo: Foram estudadas 2.318 usuárias de DIU TCu-200B no Ambulatório de Planejamento Familiar do Departamento de Tocoginecologia da UNICAMP, entre Janeiro de 1979 a Dezembro de 1983, com a finalidade de conhecer o desempenho clínico deste método anticoncepcional. Para tanto foram analisados um conjunto de variáveis suspeitas de influenciar o desempenho clinico do dispositivo: idade; paridade; antecedente de cesáreas, abortos e tipo de método anticoncepcional anterior e número de cesáreas e abortos. Após análise estatística apropriada, concluiu-se que somente a idade e o número de cesáreas anteriores influenciaram o desempenho clínico do DIU TCu-200B, ou seja, há uma relação direta entre a taxa de continuidade e a idade da paciente e inversa quanto ao número de cesáreas. Demonstrou-se assim que, para se obter um máximo desempenho deste método anticoncepcional, o dispositivo deve ser inserido preferencialmente em pacientes com mais de 25 anos de idade e sem o antecedente de cesárea. A taxa acumulada de gravidez até o quinto ano de uso foi de 5,7%, sendo considerada uma das mais baixas para este tipo de dispositivo. As causas de abandono do método por gravidez e desejo de nova gestação mostraram-se estatisticamente significantes quando se avaliou a idade e o número de cesáreas. Quanto às causas de abandono do método por expulsão e sangramento, os resultados mostraram-se significantes somente quando se analisou o número de cesáreas, resultados estes, únicos e singulares para este tipo de dispositivo. / Abstract: Two thousand three hundred and sixteen patients with Cooper T 200B (TCu-200B) intra-uterine device (IUD) were studied between january 1979 and december 1983, with the purpose of knowing the clinical performance of this contraception method. For such, some variables suspected of influencing the IUD clinical performance were analysed: age; parity; history of previous Cesaran section (C-section), abortions and contraceptive method; number of C-sections and abortions. After appropriate statistical analysis, one concludes that only age and number of previous C-sections have influence on the clinical performance of IUD TCu-200B, in other words, there is a straight relationship between the continuation rate and patient age but oppositive for number of C-sections. In order to obtain the maximum performance, the IUD should be inserted preferably in patients. more than 25 years old and with no history of previous C-sections. The acummulated pregnancy rate for the fifth year of method usage was 5.7%, considered to be very low for the IUD TCu-200B. The causes for abandoning the method due to pregnancy and desire of a new gestation, proved to be statistically significant for age; and, causes like pregnancy, expulsion and vaginal bleeding, statistically significant for C-section numbers / Mestrado / Mestre em Ciências Médicas
27

Oscilador Impatt na banda X

Cardoso, Edson Pereira 14 July 2018 (has links)
Orientador : Rui Fragassi Souza / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Campinas / Made available in DSpace on 2018-07-14T15:52:08Z (GMT). No. of bitstreams: 1 Cardoso_EdsonPereira_M.pdf: 2265476 bytes, checksum: 1a33b5e2522ef06704ebd31152f3290f (MD5) Previous issue date: 1982 / Resumo: Este trabalho trata do estudo, projeto e implementação de um oscilador Impatt na banda X. Faz-se um estudo sobre a caracterização do diodo Impatt e uma análise sobre a admitância de uma cavidade coaxial com terminação capacitiva. A interação entre o elemento ativo (o diodo) e a cavidade, através da qual ocorre a oscilação em freqüências de microondas, também e analisada. Na parte final são apresentados alguns resultados sobre o desempenho do oscilador Impatt construído em cavidade coaxial / Abstract: Not informed / Mestrado / Mestre em Ciências
28

Efetividade do sistema intra-uterino liberador de levonorgestrel nas lesões da adenomiose diagnosticada e monitorada pela ressonancia nuclear magnetica

Bragheto, Aristides Manoel dos Santos 25 August 2006 (has links)
Orientadores: Carlos Alberto Petta / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-08T00:18:42Z (GMT). No. of bitstreams: 1 Bragheto_AristidesManoeldosSantos_M.pdf: 1677539 bytes, checksum: c3f953cf02eb088df2330c79c408a064 (MD5) Previous issue date: 2006 / Resumo: O Sistema Intra-uterino liberador de Levonorgestrel (MIRENA®) tem sido usado recentemente no tratamento sintomático da adenomiose, porém o seu efeito sobre as lesões não é conhecido. O objetivo deste estudo foi avaliar a efetividade do Sistema Intra-uterino liberador de Levonorgestrel no tratamento das lesões adenomióticas. Realizou-se um ensaio clínico não aleatorizado, em que o sujeito foi o seu próprio controle, pré e pós-intervenção, ensaio do tipo N=1. Vinte e nove mulheres com idade entre 24 a 46 (média de 37,5 ± 5,1) anos, com quadro de dismenorréia e menorragia, atendidas no ambulatório de Endometriose do CAISM-Unicamp, entre 2004 e 2006, foram selecionadas após confirmação do diagnóstico da adenomiose através da ressonância nuclear magnética. Foi inserido um Sistema Intra-uterino liberador de Levonorgestrel e repetida a ressonância nuclear magnética, após seis meses da inserção, para controle das lesões. As mulheres foram reavaliadas em três e seis meses para coleta de dados. Foram avaliados a dismenorréia, através da Escala Visual Analógica de Dor, o padrão menstrual e os efeitos colaterais. As variáveis estudadas foram volume uterino, zona juncional e espessura endometrial, avaliados pela ressonância nuclear magnética, antes e após seis meses da inserção do Sistema Intra-uterino liberador de Levonorgestrel. Para a comparação pré-tratamento e seis meses após, foram realizados os testes T student pareado, Wilcoxon e teste Friedman para variáveis contínuas, e teste de McNemar para as variáveis categóricas. O nível de significância foi assumido em 5%. Os resultados obtidos foram redução do quadro menorrágico em todas as mulheres, redução significativa do quadro doloroso através da Escala Visual Analógica 80-0 (p<0,0001), da espessura do endométrio 10,2-5,8 (p<0,0001) e do percentual da zona juncional em 24,17% (p<0,0001). Houve discreta redução do volume uterino 142,6-136,4 (p=0,2077). Os efeitos colaterais mais comuns foram ganho de peso superior a 2kg (27,5%), cefaléia (20,6%), mastalgia (20,6%), seborréia e acne (6,8%) e quadro depressivo transitório resolvido sem medicação (6,8%). Nenhum Sistema Intra-uterino liberador de Levonorgestrel foi removido e não ocorreu sequer uma expulsão. Concluímos que o Sistema Intra-uterino liberador de Levonorgestrel é um tratamento clínico eficaz para tratamento dos sintomas com poucos efeitos colaterais, baixo custo e que reduz as lesões causadas pela adenomiose / Abstract: The levonorgestrel-releasing intrauterine system (MIRENA ®) has been recently used in the symptomatic treatment of adenomyosis, although its effect on the lesions is unknown. The objective of this study was to evaluate the effectiveness of the levonorgestrel-releasing intrauterine system in the treatment of adenomyotic lesion. The type of study was a clinical trial nonrandomized, where the subject is its own control, before and after the intervention, as N=1. Twenty-nine women age between 24 and 46 years old (average 37 years old ) presenting dysmenorrhea and menorrhagia were selected after the confirmed diagnosis of adenomyosis through magnetic resonance imaging in the Endometriosis Clinic of CAISM - UNICAMP between the years of 2004 and 2006. It was inserted an levonorgestrel-releasing intrauterine system and then repeated the magnetic resonance imaging 6 months later, to control the lesions. The women underwent clinic examination at the insertion and then again, three and six months later for data coletion. Dysmenorrhea was evaluated through the Visual Analogue Scale of Pain, their menstrual standard and side effects. The parameters studied were uterine volume, junctional zone, endometrial thickness evaluated through magnetic resonance imaging before and after insertion of levonorgestrel-releasing intrauterine system. To compair results before the insertion and 6 months after it, we used macthed t-student test, Wilcoxon and Friedman Test for continuous variable and Mc. Nemar for category variable. Significance level was assumed at 5%. Results were: reduction of the menstrual flow in every woman , a great reduction of pain through the Visual Analogue Scale 80 - 0 (p< 0,0001) , the endometrial thickness 10, 2 - 5, 8 (p <0,0001) and junctional zone percentage in 24,17% (p <0,0001), but with discreet uterine volume reduction 142,6 - 136,4 (p = 0,2077). The most common side effects were: weight gain superior to 2kg (27,5%), headaches (20,6%), breast tenderness (20,6%), seborrhea and acne (6,8%) and reported a transitory depressive episode (6,8%), that was solved without pharmacologic treatment. None of the levonorgestrel-releasing intrauterine system was removed or expelled. We concluded that the intra uterine system that releases levonorgestrel is an efficient symptomatic treatment, with very few side effects, low cost and that reduces lesions caused by adenomyosis / Mestrado / Tocoginecologia / Mestre em Tocoginecologia
29

Estudo da dinamica das transmissões mecanicas por trens de engrenagens planetarias

Morais, Ricardo Ferrari de 17 June 2004 (has links)
Orientador: Franco Giuseppe Dedini / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-04T00:52:54Z (GMT). No. of bitstreams: 1 Morais_RicardoFerraride_M.pdf: 12492278 bytes, checksum: f32f59831e5bafe79dc0254d8038f3e7 (MD5) Previous issue date: 2004 / Resumo: As transmissões veiculares são a forma de adaptar o torque fornecido pelo motor ao necessário para cada momento do percurso de um veículo. Dentre as várias formas possíveis de transmissões existentes estão os câmbios automáticos. Nas transmissões automáticas, os trens de engrenagens planetárias são componentes fundamentais. Esses mecanismos foram exaustivamente estudados ao longo dos anos. Seu estudo de forma combinada de dois ou mais conjuntos é recente e ainda incipiente. Este trabalho apresenta uma modelagem, dentre as possíveis, para a caixa Wilson. A caixa Wilson é uma das maneiras possíveis para a montagem de uma transmissão automática. Essa modelagem é feita com a equação de Lagrange. Uma vez feita a modelagem dinâmica é feita a modelagem do fluxo de torque. A modelagem permite a realização de simulações numéricas para a avaliação preliminar do modelo. A primeira simulação realizada forma um conjunto de dados que serve como parâmetro de comparação para os dados subseqüentes. Os resultados obtidos dessa simulação inicial apresentam são incoerentes com o esperado, desacelerações durante o acionamento das relações de transmissão. Nas simulações posteriores são realizadas variações nos parâmetros inicialmente impostos para o modelo sem carga. Essa variação de valores serve para perceber a necessidade da seleção correta dos parâmetros construtivos da transmissão e mostra, ainda, a necessidade de uma estratégia de controle para a obtenção de melhor desempenho da transmissão. Após a variação de parâmetros, partiu-se para a simulação utilizando dados realistas, cujos resultados foram qualitativamente próximos da realidade, aceleração durante o acionamento das relações de transmissão. A última etapa de simulação é a aplicação de uma carga à transmissão. Apesar de ser uma carga arbitrária, ela mostra que há uma influência significativa do carregamento no comportamento e no desempenho da transmissão / Abstract: Vehicular transmissions are the way to adapt the torque supplied by the engine to that required at each moment of the path of a vehicle. Automatic gearboxes are among severa! types oftransmissions. Epicyclic Gear Trains, EGTs, are fundamental components ofthis kind of mechanical transmission. This kind of mechanism have been studied exhaustively trough the years. The study oftwo or more EGTs is very recent indeed. This work presents a model procedure of the Wilson gearbox. The Wilson gearbox is one in severa! ways to build combinations ofEGTs in automatic gearbox. This modeling is done with the Lagrangean processo Once that the dynamic model was done it was time to model the torque flow across the transmission. Modelling allows the numerica1 simulations in order to have primary results of the model. The very first set of results was used as comparison parameter for the subsequent result sets. The results obtained in this initial simulation were not as expected deceleration whi1e setting the gear ratios. Others simulations were done with variation on the values of the initially imposed parameters. Those variations are useful to know that a real need to do an appropriated selection of the constructive parameters of the transmissions. Other important result that was got from the parameter variation was to know that a control strategy is indicated to avoid some irregular behavior of the transmission. After the parameter variation realistc data are used. These data provide result that are expected, acceleration during the gear ratio setting. The last simulations done was that one were there was a loading applied to the transmission. It was an arbitrary loading, but it showed that there is a significant influence on the behavior and performance of the Wilson gearbox / Mestrado / Mecanica dos Sólidos e Projeto Mecanico / Mestre em Engenharia Mecânica
30

Aplicação do metodo dos movimentos no estudo do efeito de uma cobertura dialetica em um dipolo em microfita

Soares, Antonio Jose Martins 15 July 2018 (has links)
Orientadores : Attilio Jose Giarola, Sergio Barroso de Assis Fonseca / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Campinas / Made available in DSpace on 2018-07-15T13:16:55Z (GMT). No. of bitstreams: 1 Soares_AntonioJoseMartins_M.pdf: 1481638 bytes, checksum: 8125a0aa80bc7e5f30a5d19ad9c017a9 (MD5) Previous issue date: 1983 / Resumo: Neste trabalho é apresentada uma análise teórica da influência de uma cobertura dielétrica em antenas de microfita, com aplicação em dipolo impresso num substrato dielétrico aterrado. Em diversas situações, as antenas de microfita podem ser cobertas por uma camada de neve ou, para a sua proteção, por urna camada dielétrica conveniente. Este carregamento altera as propriedades elétricas das antenas, como a frequência de ressonância, o que, devido à largura de banda limitada das antenas de circuito impresso, pode prejudicar o desempenho do sistema se o efeito do carregamento não for considerado no projeto. A distribuição de corrente é obtida resolvendo-se a equação de Pocklington pelo método dos momentos. O potencial de Hertz apropriado é determinado considerando-se um dipolo elementar num meio estratificado. A função de Green resultante envolve integrais do tipo Sommerfeld, que são de convergência lenta e requerem o conhecimento dos campos na região da fonte. Essas integrais são calculadas utilizando-se urna técnica de integração no eixo real que consiste de etapas numérica e analítica / Abstract: Not informed / Mestrado / Mestre em Engenharia Elétrica

Page generated in 0.0698 seconds