• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 115
  • 27
  • 22
  • 3
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 478
  • 347
  • 155
  • 105
  • 76
  • 58
  • 58
  • 54
  • 47
  • 45
  • 45
  • 45
  • 44
  • 42
  • 41
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Dosimetria da radiação cósmica no interior de aeronaves no espaço aéreo brasileiro / Cosmic radiation dosimetry onboard aircrafts at the brazilian airspace

FEDERICO, CLAUDIO A. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:34:02Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:59:36Z (GMT). No. of bitstreams: 0 / Neste trabalho, cujo objetivo foi fornecer subsídios que permitam estabelecer um sistema de dosimetria para as tripulações de aeronaves que operam no território nacional, foi desenvolvida uma técnica para realizar medições do equivalente de dose ambiente em aeronaves. Foi testado um detector ativo, para uso embarcado em aeronaves, avaliando-se sua adequação a este tipo específico de medição, assim como sua suscetibilidade às interferências magnética e eletromagnética. O equipamento foi calibrado em campos metrologicamente rastreados e foi verificado em um campo especial do laboratório europeu CERN, que reproduz com grande proximidade o espectro de partículas existentes em altitudes de voo de aeronaves, sendo a seguir testado em diversos ensaios em voo, em uma aeronave da Força Aérea Brasileira. Os resultados foram avaliados e comparados com aqueles obtidos por diversos programas computacionais de estimativa de dose oriunda de radiação cósmica, com respeito à sua adequação para uso na região da América do Sul e foi selecionado o programa CARI-6 para avaliar as doses efetivas médias estimadas a que estão sujeitas as tripulações que operam nesta região. Foi efetuada uma avaliação estatística da distribuição de doses efetivas das tripulações dos voos que operam na região da América do Sul e Caribe e concluiu-se que grande parte destas tripulações estão sujeitas a doses efetivas anuais que ultrapassam o limite estabelecido para membros do público. Adicionalmente, foi proposto um dosímetro passivo preliminar, baseado em detectores termoluminescentes, e foram ainda estabelecidas colaborações internacionais com grupos de pesquisa do Reino Unido e da Itália, para a realização de medições conjuntas do equivalente de dose ambiente em aeronaves. / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
82

Desenvolvimento de uma metodologia de calibração e testes de medidores de produto Kerma-Área / Development of a calibration methodology and tests of kerma area product meters

COSTA, NATHALIA A. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:41:31Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:59:54Z (GMT). No. of bitstreams: 0 / A grandeza produto kerma-área (PKA) é importante para estabelecer níveis de referência em exames de radiologia diagnóstica. Essa grandeza pode ser obtida por meio de medidores do PKA. O uso desses medidores é fundamental para avaliar a dose de radiação em procedimentos radiológicos, além de ser um bom indicador para que os limites de dose na pele do paciente não sejam excedidos. Algumas vezes, esses medidores vêm acoplados a equipamentos de radiação X, o que dificulta sua calibração. Neste trabalho foi desenvolvida uma metodologia de calibração de medidores do PKA. O instrumento utilizado para este fim foi o Patient Dose Calibrator (PDC). Ele foi desenvolvido para ser utilizado como referência na verificação da calibração de medidores do PKA e kerma no ar usados na dosimetria de pacientes e para verificação da consistência e do comportamento de sistemas de controle de exposição automáticos. Por se tratar de um equipamento novo, que, no Brasil, ainda não é utilizado como equipamento de referência para calibração, foi realizado, também o controle de qualidade deste equipamento, com testes de caracterização, a calibração e a avaliação da dependência energética. Após os testes, ficou provado que o PDC pode ser utilizado como instrumento de referência para a calibração a ser realizada in situ, de forma que as características de cada equipamento de radiação X onde os medidores do PKA são utilizados sejam consideradas. A calibração foi, então, realizada com medidores do PKA portáteis e em um equipamento de radiologia intervencionista que possui um medidor do PKA acoplado. Os resultados foram bons e ficou provada a necessidade de calibração desses medidores e a importância da calibração in situ com um medidor de referência. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
83

Fracao absorvida especifica no tecido osseo e medula ossea resultante de fotons distribuidos no esqueleto

HIROMOTO, GORO 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:30:40Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:59:54Z (GMT). No. of bitstreams: 1 00325.pdf: 1838359 bytes, checksum: e31db591c99b96c7df4d4760002d6c35 (MD5) / Dissertacao (Mestrado) / IEA/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
84

Desenvolvimento de uma nova metodologia para o calculo de dose em dosimetria fotografica

DALTRO, TERESINHA F.L. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:37:43Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:00:16Z (GMT). No. of bitstreams: 1 05383.pdf: 5069239 bytes, checksum: 7eb90d0ab97b4fe286a135fef870f96f (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
85

Desenvolvimento de cálculos de unidades monitoras para IMRT / Development of monitor unit calculation in IMRT

FLOSI, ADRIANA A. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:34:36Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:00:37Z (GMT). No. of bitstreams: 0 / A verificação de forma independente do cálculo de dose e de unidades monitoras num plano de tratamento de IMRT é um passo importante nos procedimentos de garantia de qualidade da técnica em questão. Atualmente este verificação é baseada apenas em medidas experimentais demoradas e trabalhosas. Neste trabalho foi desenvolvido uma metodologia de cálculo de unidades monitoras de forma independente como uma nova ferramenta para garantir a qualidade e exatidão dos tratamentos de IMRT. Os valores encontrados se aproximam bastante dos valores calculados pelo sistema de planejamento utilizado, de forma que o algoritmo de cálculo desenvolvido apresentou uma concordância dentro de ± 1,8 % para uma geometria simples. Após diversos testes e com os níveis de ação devidamente estabelecidos, a verificação independente da unidade monitora para planos de tratamento de IMRT se tornará uma ferramenta efetiva e eficiente no controle de qualidade que ajuda a identificar e reduzir possíveis erros de tratamento em radioterapia. Como contribuição original deste trabalho, assegura-se aos serviços de Radioterapia a utilização da metodologia desenvolvida como ferramenta de controle de qualidade em tratamentos com IMRT. Em especial aos serviços que não dispõem de recursos econômicos para adquirirem softwares comercialmente disponíveis para o cálculo independente da unidade monitora. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
86

Determinacao de sup210 Pb e sup210 Po em aguas minerais radioativas

NIERI, ARTIDORO 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:40:56Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:01:27Z (GMT). No. of bitstreams: 1 04024.pdf: 3628243 bytes, checksum: 85a871f2396f235238f333eefec1e8ab (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
87

Padronização do método de dosimetria retrospectiva empregando a técnica de ressonância paramagnética eletrônica e hidroxiapatita

PEREIRA, FABIO A. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:50:20Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:02:02Z (GMT). No. of bitstreams: 1 10888.pdf: 3706932 bytes, checksum: b0237234bef6a446b65c83bd4e3205cc (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
88

Aplicacao de modelos metabolicos para a determinacao de funcoes de excrecao e retencao

RODRIGUES JUNIOR, ORLANDO 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:37:35Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:03:23Z (GMT). No. of bitstreams: 1 02232.pdf: 3951264 bytes, checksum: dbd0c0050958a2578e3ec58da9f6ac83 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
89

Impacto radiologico devido ao transporte de radiofarmacos do IPEN-CNEN/SP / Radiological impact from the transport of radiopharmaceuticas IPEN-CNEN/SP

RODRIGUES, DEMERVAL L. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:26:29Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:04:25Z (GMT). No. of bitstreams: 0 / Quando um embalado é transportado, as pessoas que trabalham, residem ou circulam no itinerário percorrido pelo transporte de materiais radioativos são irradiadas, assim como aquelas pessoas que estão dentro dos veículos que viajam no mesmo sentido ou no sentido contrário. Desta forma, o trabalho proposto tem como principal objetivo estimar o impacto radiológico resultante do transporte de radiofármacos do IPEN - CNEN/SP até alguns destinos previamente definidos. Para isso, foram estimadas as doses nos indivíduos do público que estão nas ruas e nos veículos que trafegam próximos dos meios de transporte, ao longo do itinerário percorrido pelos embalados, durante a realização dos transportes dos radiofármacos. Foram estimadas as doses, também, para os trabalhadores, resultantes tanto da operação de condução do meio de transporte como das operações de carga e descarga dos embalados, já que estas tarefas são executadas pelo mesmo trabalhador. / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
90

Desenvolvimento do manequim matematico do homem brasileiro para calculos de dosimetria interna

GUIMARAES, MARIA I.C.C. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:38:44Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:04:51Z (GMT). No. of bitstreams: 1 06045.pdf: 15655492 bytes, checksum: 6cfb83e47451ce75631c870bbce0e7cd (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP

Page generated in 0.0331 seconds