• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 115
  • 27
  • 22
  • 3
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 478
  • 347
  • 155
  • 105
  • 76
  • 58
  • 58
  • 54
  • 47
  • 45
  • 45
  • 45
  • 44
  • 42
  • 41
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Propriedades de termoluminescencia do LiF:Mg

WATANABE, SHIGUEO 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:24:54Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:04:54Z (GMT). No. of bitstreams: 1 01042.pdf: 2867797 bytes, checksum: 7d025b68770b969cf1af56bb1194ce50 (MD5) / Tese (Livre docencia) / IEA/T / Faculdade de Filosofia Letras e Ciencias Humanas, Universidade de Sao Paulo - FFLCH/USP
92

Desenvolvimento e estudo de materiais termoluminescentes baseados em óxido de alumínio para aplicação em dosimetria / Development and study of thermoluminescent materials based on aluminium oxide for dosimetry application

FUKUMORI, DAVID T. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:32:58Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:11Z (GMT). No. of bitstreams: 0 / O óxido de alumínio foi um dos primeiros compostos investigados, com vista a detectar e medir a radiação por meio da termoluminescência (TL). Comumente referido como \"alumina\", o óxido de alumínio tem características interessantes para o desenvolvimento de materiais para a dosimetria. Seu número atômico efetivo é intermediário entre o do osso e do tecido mole do corpo. Pode ser transformado em material termoluminescente pela inserção de elementos químicos em sua estrutura cristalina. Além da TL, a alumina pode apresentar luminescência opticamente estimulada (OSL), fenômeno que também pode ser usado para determinar a dose de radiação. Neste estudo, dois métodos foram investigados para inserir íons metálicos na alumina. O primeiro método foi baseado na capacidade de adsorção da alumina e o segundo denominado método da coprecipitação foi baseado na formação simultânea de compostos insolúveis. As amostras obtidas por adsorção de íons Cu2+ e Mn2+ não mostraram resultados satisfatórios. No entanto, as pastilhas de óxido de alumínio impurificado com Tm3+ via coprecipitação mostraram sinais de TL e OSL. Foi verificado também que a alumina eletrofundida disponível comercialmente é um material que apresenta resposta TL e OSL. Este material que contém diversos íons metálicos em sua estrutura foi transformado em pastilhas por sinterização com vidro. As curvas da resposta TL em função da temperatura e da resposta TL e OSL em função da dose foram determinadas. Os resultados obtidos indicam que estudos mais aprofundados das pastilhas desenvolvidas podem melhorar suas características para que sejam aplicadas em dosimetria. / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
93

Propriedades termoluminescentes do fluoreto de calcio natural

OKUNO, EMICO 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:23:47Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:36Z (GMT). No. of bitstreams: 1 01265.pdf: 3555927 bytes, checksum: 1f15fc90d6320240cb55282e4d484224 (MD5) / Tese (Doutoramento) / IEA/T / Instituto de Fisica, Universidade de Sao Paulo - IF/USP
94

Desenvolvimento do fantasma matematico de uma crianca de 10 anos de idade para fins de dosimetria interna

DEUS, SUDERNAIQUE F. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:26:09Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:41Z (GMT). No. of bitstreams: 1 01056.pdf: 9216178 bytes, checksum: 1bd6e90e03bfc38d02eb59996c618992 (MD5) / Tese (Doutoramento) / IEA/T / Instituto de Energia Atomica - IEA
95

Dosimetria biologica em protecao radiologica. Elaboracao de curvas dose-reposta para o Cosup60 e Cssup137

SILVA, MARCIA A. da 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:42:55Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:07:39Z (GMT). No. of bitstreams: 1 05407.pdf: 4903042 bytes, checksum: 419915481d530053b3055a4afa7c0e1f (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
96

Avaliacao das consequencias radiologicas de liberacoes rotineiras em sitio com varias intalacoes nucleares

LUCINIO, ELENA A.G. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:47:58Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:07:23Z (GMT). No. of bitstreams: 1 09023.pdf: 5020333 bytes, checksum: fad008e6f2df7382a16c31dafc1045b1 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
97

Caracterizacao de sistemas tandem de camaras de ionizacao comerciais para dosimetria de feixes de raio X (nivel radioterapia)

GALHARDO, EDVALDO P. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:43:06Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:08:03Z (GMT). No. of bitstreams: 1 06118.pdf: 5177469 bytes, checksum: 1a0ed58fc3fd28df339dcde05cba57d4 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
98

Dosimetria biologica citogenetica em protecao radiologica .Analise de aberracoes cromossomicas radioinduzidas em linfocitos humanos

CAMPOS, ISIDA M.A. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:32:46Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:08:48Z (GMT). No. of bitstreams: 1 03362.pdf: 1393147 bytes, checksum: 01489b7356e00847fe76c389e08056f8 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
99

Calculo de Monte Carlo da dose equivalente recebida por um feto humano de fontes gama localizadas no trato-gastrointestinal

SEGRETO, VERA S.A. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:26:01Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:10:08Z (GMT). No. of bitstreams: 1 00459.pdf: 1460675 bytes, checksum: 4ee7893eae68fa2c5b514f7d0a9872b8 (MD5) / Dissertacao (Mestrado) / IEA/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
100

Novas rotas de preparação de filmes de polianilina e caracterização dosimétrica para radiação gama em altas doses

Paula Lima Pacheco, Ana January 2003 (has links)
Made available in DSpace on 2014-06-12T23:14:57Z (GMT). No. of bitstreams: 2 arquivo8993_1.pdf: 2950400 bytes, checksum: 22e85ebad0ed18e65dfe07ff3a73864d (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2003 / Este trabalho apresenta um novo material polimérico condutor, a base de polianilina (PANI) na forma de filmes finos, que foi utilizado na confecção de dispositivos com fins dosimétricos. Para o preparo dos dispositivos os filmes foram depositados sobre as superfícies de substratos de poli(metacrilato de matila) (PMMA). Esta deposição foi feita através do espalhamento de uma pasta altamente viscosa e homogênea, contendo poli(ácido acrílico) e agente oxidante (MnO2), sobre as superfícies dos substratos de PMMA (formando uma película). Em seguida o substrato contendo a película foi imerso em uma solução ácida de anilina resultando na formação dos filmes. Os filmes formados por esta nova metodologia de síntese apresentam resistividade elétrica (6 x 102 W. m.), boa resistência mecânica e maior aderência aos eletrodos do sistema, quando comparados com os primeiros dispositivos desenvolvidos. A caracterização foi feita por infravermelho, medidas de condutividade elétrica e pela análise elementar de manganês. Os resultados dos ensaios dosimétricos mostraram: correlação linear (r2 = 0,9928) para variação da resistência elétrica em função da dose de irradiação gama, na faixa de 1000 6000 Gy; erro médio menor que 5%; sensibilidade de resposta; e estabilidade de suas propriedades por três dias antes e após a irradiação. A utilização do compósito PANI/poli(ácido acrílico) como dosímetro, para aplicações em instalações industriais que trabalhem com altas doses de radiação gama, foi estudada e resultou em uma curva de calibração com excelentes resultados. Os dispositivos dosimétricos preparados de acordo com esta nova rota apresentam leitura em tempo real e são de baixo custo. Sendo assim, podem vir a ser utilizados para calibração de fontes radioativas industriais, substituindo com eficácia o dosimetro Fricke (modificado) que vem sendo utilizado neste intervalo de dose

Page generated in 0.0252 seconds