31

Extension et validation de bGPUMCD, un algorithme de calcul de dose Monte Carlo pour la curiethérapie implémenté sur processeur graphique

Joachim-Paquet, Charles 02 February 2024 (has links)
Le présent mémoire présente les récents travaux de développement d'un algorithme de calcul de dose monte carlo en brachythérapie implémenté sur GPU (bGPUMCD, GPU Monte Carlo Dose for brachytherapy) ainsi que la validation des résultats et de la performance de celui-ci en vue d'une utilisation clinique future pour les cas de curiethérapie HDR et d'une utilisation académique permettant de remplacer l'utilisation de codes Monte Carlo plus lents dans le domaine académique. Les cas de test définis par le Groupe de travail sur les algorithmes de calcul de dose en curiethérapie (WG-DCAB, Working Group on Dose Calculation Algorithms in Brachytherapy)[1] et quatre cas de patients cliniques représentant des sites de traitement représentatifs sont utilisés pour explorer la précision, la vitesse et les limites de l'algorithme dans une multitude de contextes. bGPUMCD est comparé aux résultats de calcul de dose provenant de plusieurs codes Monte Carlo tel que MCNP6 et ALGEBRA[2]. Les résultats obtenus par bGPUMCD sont dans les limites d'incertitudes requises par les recommandations du Rapport du Groupe de Travail No.186 de l'AAPM (TG-186, Report on the Task Group No.43)[3]. Une simulation en situation de Rapport du Groupe de Travail No.43 de l'AAPM (TG-43, Report on the Task Group No.43)[4] a été effectuée pour trois modèles de source et les fonctions 𝑔𝐿(𝑟) et 𝐹 (𝑟, 𝜃) obtenues correspondent avec une erreur de 2 % aux valeurs de référence à l'exception des grands angles. Nous démontrons aussi que bGPUMCD est capable de simuler une dose cliniquement équivalente à un code Monte Carlo de référence en une fraction du temps ; en fonction des différents paramètres pouvant modifier le temps de calcul, bGPUMCD permet d'obtenir un résultat équivalent à la dose de référence avec un temps de calcul se trouvant entre quelques secondes à quelques minutes par rapport à plusieurs heures pour ALGEBRA.
32

Planification multimodale et optimisation de la dose pour la radiothérapie externe du cancer du poumon

St-Hilaire, Jason 19 April 2018 (has links)
L'objectif de cette thèse est d'améliorer les traitements du cancer du poumon en radiothérapie par modulation d'intensité (IMRT) réalisés grâce à un logiciel maison (Ballista) et à un logiciel commercial (Pinnacle3 de Philips). Dans un premier temps, nous avons constaté que de mélanger les basses et hautes énergies dans un même plan permettait d'obtenir une meilleure épargne des tissus périphériques tout en conservant la couverture du volume cible et l'épargne des organes sensibles. Ensuite, le système Ballista a été mis à profit pour explorer les limites d'augmentation de la dose à la tumeur pour des plans d'IMRT simples. En explorant des configuration d'angles non coplanaires, la dose à la maladie macroscopique a pu être augmentée à des niveaux supérieurs à 78 Gy dans un nombre important de cas, sans augmentation excessive de la dose aux organes à risque. Finalement, nous avons utilisé des images de perfusion pulmonaire acquises par tomographie par émission monophotonique (TEM) pour caractériser spatialement et quantitativement la fonction pulmonaire et obtenir des plans qui évitent les régions les plus saines. Nous avons cherché à identifier une méthode simple et avantageuse pour générer ces plans. Toutes les méthodes tentées ont permis d'obtenir un gain incrémentiel sur l'épargne des régions fonctionnelles. Nous n'avons cependant pas pu trouver de corrélation possible entre l'épargne fonctionnelle obtenue et divers paramètres géométriques spécifiques à chaque patient. Le grand résultat de cette thèse a été la création d'un cadre d'applications pour un système de planification 5D, combinant ainsi les trois dimensions de l'espace, la dimension temporelle (mouvements intrafraction et interfraction) et la dimension de l'information fonctionnelle. On pourrait ainsi imaginer un logiciel permettant d'optimiser les angles d'incidence des faisceaux en tenant compte de la distribution spatiale de la fonctionnalité (autant tumorale que celle des tissus normaux), avec une définition de volume cible tenant compte du déplacement intrafraction des structures internes et avec un niveau de modulation suffisant pour obtenir une conformité accrue.
33

Développement d'un modèle de tumeur oculaire dans un hydrogel pour les mesures de dose en brachythérapie du mélanome uvéal

Gros-Louis, Philippe 10 May 2024 (has links)
Le mélanome uvéal est la tumeur primaire intraoculaire la plus fréquente chez l'adulte. L'un des traitements le plus souvent utilisé afin d'obtenir un contrôle local de la tumeur s'appelle la curiethérapie par plaque. Malgré un faible taux de récidive locale avec cette technique, la grande majorité des patients développeront des complications oculaires secondaires à la radiation cinq ans après le diagnostic initial. Le manque de modèles ex vivo ou in vitro de mélanome uvéal rend difficile la validation de plaques de curiethérapie personnalisées et le calcul des différents profils de dose par les algorithmes Monte-Carlo. Un fantôme dosimétrique bio-imprimé représentant l'œil humain contenant une tumeur uvéale de forme définie serait un modèle in vitro optimal pour l'évaluation de différents profils de dose dans le développement de plaques de curiethérapie personnalisées. Dans cette étude, la viabilité et la prolifération des cellules cancéreuses du mélanome uvéal ainsi que des fibroblastes et mélanocytes choroïdiens en culture dans un environnement tridimensionnel, soit une matrice extracellulaire commerciale (Matrigel®) ou un hydrogel imprimable, ont d'abord été mesurées par microscopie en contraste de phase ou en fluorescence. Ensuite, l'expression de marqueurs de prolifération, d'hypoxie et de dommages à l'ADN a été déterminée dans les cellules cancéreuses du mélanome uvéal cultivées en monocouche ou enrobées dans le Matrigel®, dans l'optique future d'étudier ces marqueurs lors de l'irradiation du modèle bio-imprimé de tumeur uvéale avec une plaque personnalisée. L'évaluation chirurgicale de prototypes de plaques de curiethérapie non radioactives a été faite afin de comparer les différentes itérations entre elles et aux plaques conventionnelles. Enfin, les caractéristiques à améliorer pour le développement d'un modèle biologique contenant une tumeur uvéale ont été discutées et les aspects techniques problématiques des premières plaques imprimées ont été identifiés afin d'optimiser les prochains prototypes de plaques personnalisées. Mes travaux représentent un avancement des connaissances sur les modèles in vitro 3D du mélanome uvéal et le traitement de cette tumeur oculaire par curiethérapie par plaque. Mon mémoire pourra servir de base aux projets subséquents visant soit i) à élucider l'impact des interactions des cellules cancéreuses avec leur microenvironnement sur la résistance thérapeutique de ce cancer ou ii) à tester de nouvelles stratégies thérapeutiques sur un modèle bio-imprimé de mélanome uvéal primaire. / Uveal melanoma is the most common primary intraocular tumor in adults. One of the treatments most often used to achieve local tumor control is called plaque brachytherapy. Despite a low local recurrence rate with this technique, most patients will develop ocular complications secondary to radiation five years after the initial diagnosis. The lack of ex vivo or in vitro models of uveal melanoma makes it difficult to validate personalized brachytherapy plates and to calculate the different dose profiles by Monte-Carlo algorithms. A bioprinted dosimetry phantom representing the human eye containing a defined uveal tumor would be an optimal in vitro model for the evaluation of different dose profiles in the development of personalized brachytherapy plates. In this study, the viability and proliferation of uveal melanoma cells, as well as choroidal fibroblasts and melanocytes in culture in a three-dimensional environment, either a commercial extracellular matrix (Matrigel®) or a printable hydrogel, were first measured by phase contrast or fluorescence microscopy. Then, the expression of markers of proliferation, hypoxia and DNA damage was determined in uveal melanoma cells cultured as monolayer or embedded in Matrigel®, in the future perspective of studying these markers after the irradiation of the bioprinted uveal tumor model using a personalized plate. The surgical evaluation of prototypes of non-radioactive brachytherapy plates was done in order to compare the different iterations with each other and with conventional plates. Finally, the characteristics to be improved for the development of a biological model containing an uveal tumor were discussed, and the problematic technical aspects of the printed plates were identified in order to optimize the next prototypes of personalized plates. My work represents an advancement of knowledge on in vitro 3D models of uveal melanoma and the treatment of this ocular tumor by plaque brachytherapy. My master's thesis could serve as a basis for subsequent projects aiming either i) to elucidate the impact of interactions of cancer cells with their microenvironment on the therapeutic resistance of this cancer or ii) to test new therapeutic strategies on a bioprinted model of primary uveal melanoma.
34

Caractérisation de points quantiques comme matériau luminescent pour applications en dosimétrie

Delage, Marie-Ève 06 April 2024 (has links)
La thèse présentée porte sur l’investigation d’un nouveau matériau luminescent pour une application en dosimétrie à scintillation, un matériau développé pour la première fois il y a environ une vingtaine d’années : les points quantiques colloïdaux (cQDs). Ces derniers sont des nanocristaux de semi-conducteurs possédant des propriétés uniques, découlant entre autres du confinement tridimensionnel de leurs porteurs de charge. Les cQDs constituent un matériau d’intérêt pour la dosimétrie à scintillation d’abord grâce à leur luminescence dont l’intensité est bonifiée par rapport à celle de leur équivalent macroscopique. Plusieurs autres propriétés des cQDs les rendent intéressants pour le développement d’un dosimètre à scintillation. Ils possèdent un large spectre d’absorption et un étroit spectre d’émission, dont la position du maximum d’absorption (émission) est dépendante de la taille et de la composition des cQDs. De plus, il existe de multiples supports physiques dans lesquels peuvent être insérés les cQDs, des supports comme divers solvants ou plastiques. Peu de travaux ont été menés sur la caractérisation de cQDs comme scintillateurs, spécialement dans le contexte d’une application en dosimétrie à scintillation pour la radio-oncologie. Une panoplie d’avenues nécessitaient donc d’être explorées pour établir un portrait des cQDs comme matériau luminescent pour des applications en dosimétrie. Plusieurs formes physiques dans lesquelles étaient inclus les cQDs ont été testées : de la poudre, des liquides et des plastiques. La majeure partie de la thèse traite de la caractérisation de cQDs comme scintillateur, mais une portion de la thèse porte aussi sur le développement d’instrumentation spécifique à la mesure aux accélérateurs linéaires. Celui-ci a été motivé par le fait que l’accélérateur linéaire a un rapport cyclique de 0,144%, faisant en sorte que la majorité de l’intégration continue de signal lumineux collecte du bruit. Un prototype de circuit intégrateur synchronisé a donc été développé, ce qui a permis de faire un gain sur le rapport signal sur bruit du signal mesuré. Concernant la caractérisation des cQDs, la première étude présentée rapporte les résultats d’une comparaison de la résistance à la radiation ionisante de cQDs à coquille simple et de cQDs à coquilles multiples, ce dernier étant le type utilisé pour le projet de thèse. Il a été montré que les cQDs à coquilles multiples ont une meilleure résistance à la radiation que les cQDs à coquille simple grâce à leur meilleure passivation de surface. De plus, la répétition de multiples irradiations entrecoupées de pauses a fait ressortir deux effets antagonistes pour chaque type de cQDs concernant la récupération, ou non, de leur efficacité de scintillation. Les cQDs à coquille simple ont présenté une accélération de la dégradation de leur scintillation entre les pauses alors que les cQDs à coquilles multiples ont présenté un recouvrement systématique de leur intensité de scintillation. Ensuite, une étude portant sur les dispersions liquides de cQDs est présentée. On en retire que l’efficacité de scintillation dépend de la nature du solvant dans lequel sont dispersés les cQDs. L’alkylbenzène, le meilleur solvant, permet notamment d’obtenir une intensité de scintillation constituant le dixième de celle du scintillateur commercial Ultima Gold, et ce, malgré que la concentration de cQDs soit cinq ordres de grandeur plus faible que celle du fluorophore dans Ultima Gold. La dernière étude présentée porte sur la poursuite de la caractérisation des formes poudreuse et liquide de cQDs comme dosimètres. Des mesures rapportant la linéarité du signal en fonction de la dose déposée ont été menées pour des faisceaux de photons et d’électrons. D’autres mesures ont permis de caractériser la dépendance du signal en fonction de l’énergie du faisceau. Il a été montré que les dispersions liquides ont la dépendance la moins marquée, ayant une variation maximale de 15% à 220 kVp par rapport au signal à 6 MV pour la dispersion dans l’alkylbenzène. Cette variation se trouve même à être plus petite que celle observée pour la fibre scintillante BCF-60 et pour Ultima Gold. Quelques résultats préliminaires sont finalement rapportés concernant les scintillateurs plastiques de cQDs. Entre autres, il a été observé, aux énergies kV, que la dépendance en énergie du signal suit une tendance similaire à celle du BCF-60, mais dont l’amplitude de variation est moindre. En conclusion, chacune des formes de cQDs testées possède des particularités qui pourraient mettre de l’avant son utilisation en dosimétrie à scintillation. Ces dernières sont relatées en détail dans la conclusion de la thèse. / This thesis presents the investigation of a new luminescent material as the sensible volume of scintillating dosimeters, a material which has been developed in the past twenty years: colloidal quantum dots (cQDs). These nanocrystals are composed of semiconductors and have unique properties, which are in part due to the three-dimensional quantum confinement of their charge carriers. cQDs constitute a material of interest for scintillation dosimetry since they have a more important light emission than their bulk counterpart. Moreover, they have a wide absorption and a narrow emission spectrum, for which their maximum absorption (emission) is tuneable with the cQD size and composition. The cQDs can be incorporated to many physical supports like liquids or plastics. Few studies have characterized cQDs as scintillators for an application in radiation oncology dosimetry. Thus, many research paths had to be explored to establish the portrait of cQDs as a luminescent material for applications in dosimetry. cQDs under multiple physical forms were tested: powder, liquids and plastics. Even though the major part of the thesis deals with the characterization of cQDs, work has been done on improving the light signal collection. This part of the project was motivated by the low duty cycle of the linear accelerator (0.144%), which results in a continuous light acquisition including a lot of noise. Thus, a prototype of an integrated synchronized circuit was developed and lead to a better signal to noise ratio of the light signal collected, evaluated to be up to 8 times better. The first study on the cQD characterization reports the comparison results of the resistance to ionizing radiation of core/shell (CS) and multishell (MS) cQDs, the type that is used throughout the thesis. MS cQDs have proven to have a better radiation resistance than CS cQDs due to their better surface passivation. Moreover, repeated irradiations separated with pauses put forward an opposite trend concerning the effect of the pauses on the recovery of the scintillation efficiency. CS cQDs presented an accelerated degradation of their light production efficiency while MS cQDs showed a systematic scintillation efficiency recovery. In the second study, measurements were conducted in order to characterize the cQD liquid dispersions. It was observed that the cQD dispersion scintillation efficiency was dependent on the nature of the solvent. The alkylbenzene dispersion, offering the best light production, wasshown to reach a tenth of the light emission intensity of the commercial scintillator Ultima Gold. This observation is remarkable since the cQD concentration is five orders of magnitude lower than the fluorophore concentration in Ultima Gold. The last study presents the continuing characterization of the cQD powder and the cQD liquid dispersions as dosimeters. It is reported that their scintillation output is linear with dose when the cQDs are irradiated with various photon and electron beam energies. The light output dependence on beam energy was also quantified and it was shown that the cQD liquid dispersions have the least important dependence. Indeed, the alkylbenzene dispersion has a maximal signal variation from 6 MV of 15% observed at 220 kVp, a variation lower than what was reported for the scintillating fiber BCF-60 and Ultima Gold. Preliminary results are also presented for the cQD plastic scintillators. At kV energies, it was observed that the energy dependence of the scintillation output followed a similar trend than that of the BCF-60’s but had a lower variation amplitude. To conclude, each of the cQD forms has a potential in being used for scintillation dosimetry considering their proper particularities. These particularities are discussed in detail in the conclusion of the thesis.
35

Détermination de l'incidence de l'ajout d'un fluorophore à l'eau sur la dosimétrie Cherenkov en radiothérapie externe

Jean, Emilie 12 April 2024 (has links)
Le passage de particules chargées dans un milieu ayant une vitesse excédant celle de la lumière dans ce même milieu entraîne l’émission de photons. Ce phénomène, nommé effet Cherenkov, peut être utilisé afin de déterminer la dose déposée dans un fantôme d’eau par un accélérateur linéaire utilisé en radiothérapie externe. Toutefois, les photons Cherenkov sont toujours émis de façon anisotrope et rendent le calcul de la dose complexe en raison de l’absence de linéarité entre l’intensité collectée et la dose déposée. Une alternative proposée par certains consiste à ajouter un fluorophore à l’eau afin d’absorber une portion de la lumière Cherenkov anisotrope et la réémettre de façon isotrope par fluorescence. Afin d’évaluer l’efficacité de cette méthode, la présente étude vise à déterminer les proportions de chaque processus d’émission lors de l’irradiation d’une solution aqueuse de quinine et quantifier l’absorption de photons Cherenkov par le fluorophore. Cela devait permettre de mieux comprendre les mécanismes menant à une amélioration de la mesure de dose lors de l’ajout du fluorophore. Pour ce faire, diverses concentrations de solution aqueuse de quinine ont été irradiées à l’aide d’un accélérateur linéaire et le spectre émis a été recueilli à l’aide d’un spectromètre. Afin de déterminer la quantité de photons produits initialement dans le solvant par effet Cherenkov, une solution témoin constituée uniquement d’eau distillée a été irradiée sous les mêmes conditions. De plus, à l’aide de l’intensité lumineuse mesurée par une caméra CCD, une comparaison de la mesure de la dose déposée a été réalisée entre l’eau et la solution de quinine. Finalement, ces mesures de dose expérimentales ont été comparées avec les doses prédites par un système de planification de traitement afin de quantifier l’amélioration observable lors de l’ajout du fluorophore. / Particles traveling through a medium at a speed exceeding light speed in that same medium gives rise to a phenomenon of photon emission. This phenomenon, called the Cherenkov effect, can be used to determine the dose deposition in a water phantom from a linear accelerator used in external radiotherapy. However, Cherenkov effect produces an anisotropic emission which makes the calculation of the dose complex as the relation between the dose deposition and the intensity of the signal collected is not linear. An alternative recently proposed consist of adding a fluorescent agent to the water with the hypothesis that it can absorb the Cherenkov emission and reemit it as an isotropic fluorescent light. To evaluate the efficiency of this method, the present study aims to determine the contribution of each excitation source producing the total light signal measured in the visible range during the irradiation of an aqueous quinine solution. Moreover, it aims to quantify the Cherenkov light absorption by the fluorophore in the UV region. To achieve this, various concentrations of aqueous quinine solutions were irradiated with a linear accelerator and the spectra where collected with a spectrometer. To determine the initial Cherenkov light production in the solvent, a control sample of distilled water was irradiated under the same conditions as the fluorophore solutions. Furthermore, using the light signal collected by a CCD camera, a comparison between the dose deposition along the beam path was performed between the quinine solution and the pure Cherenkov light. It was then possible to compare the percent depth dose obtained with both solution with a treatment planning system dose calculation to determine how quinine improves measurements.
36

Deep learning-based advanced dose calculations in low-dose rate prostate brachytherapy

Berumen, Francisco 17 July 2024 (has links)
La curiethérapie, une forme spécialisée de traitement du cancer, consiste à placer des sources radioactives près ou directement dans la lésion cancéreuse. Un aspect crucial de cette thérapie est le calcul de la dose de radiation. Traditionnellement, ce calcul s'appuie sur un formalisme qui considère l'eau comme milieu de transport, ce qui ne tient pas suffisamment compte des variations dans la composition des tissus du patient et des effets d'atténuation entre sources pour la curiethérapie permanente à faible débit de dose (LDR pour low-dose rate). La méthode Monte Carlo (MC) est la référence pour les calculs de dose avancés en curiethérapie, offrant une solution à ces limites. Cependant, l'application pratique de la méthode MC dans la planification du traitement est limitée par son temps d'exécution relativement lent. Cette thèse explore le potentiel des méthodes d'apprentissage profond (DL pour deep learning) pour surmonter ce défi. Plus précisément, la faisabilité d'utiliser des algorithmes DL pour prédire rapidement et avec précision la distribution de dose volumétrique pour patients de cancer de la prostate traités par la curiethérapie LDR est étudiée. Premièrement, le logiciel TOPAS a été systématiquement validée pour les simulations MC en curiethérapie en comparant les résultats simulés avec les données de référence TG-186 publiées. Le spectre d'énergie d'émission de photons, l'air-kerma strength et la constante de débit de dose de la source générique $^{192}$Ir MBDCA-WG ont été extraits. Pour les calculs de dose, un estimateur de longueur de trajectoire a été validé. Les quatre cas de test du groupe de travail MBDCA-WG AAPM/ESTRO/ABG ont été évalués. Un cas de prostate, un cas palliatif de poumon et un cas de sein ont été simulés. L'air-kerma strength et la constante de débit de dose étaient respectivement à 0,3% et 0,01% des valeurs de référence. Pour tous les cas de test, 96,9% des voxels avaient des différences de dose locales dans une plage de ±1%, tandis que les différences de dose globales concernaient 99,9% des voxels dans une plage de ±0,1%. Les histogrammes dose-volume des cas cliniques étaient cohérents avec les données de référence. TOPAS offre un accès étendu à un code MC de pointe pour les simulations en curiethérapie. Deuxièmement, un modèle DL à source unique entraîné avec des simulations MC comme référence a été proposé pour prédire avec précision les distributions de dose dans le milieu (D$_\textup{M,M}$ pour dose to medium in medium) en curiethérapie prostatique LDR. Des connaissances antérieures ont été incluses dans le réseau sous forme de noyau r$^2$ lié à l'inverse de la dépendance de dose de premier ordre en curiethérapie. Les caractéristiques du modèle montraient une représentation anisotrope tenant compte des organes du patient et de leurs interfaces, de la position de la source et des régions de faible et haute dose. La métrique CTV D$_{90}$ prédite présentait une différence moyenne de -0,1% par rapport au calcul basé sur MC. La prédiction d'un volume D$_\textup{M,M}$ complet de 1,18 M de voxels se réalise en 1,8 ms. Le modèle DL proposé représente donc un algorithme de calcul extrêmement rapide et simplifié, intégrant des connaissances physiques préexistantes pertinentes à la curiethérapie. Ce modèle est conçu pour tenir compte des caractéristiques anisotropes d'une source de curiethérapie et de la composition spécifique des tissus du patient, garantissant une approche précise et adaptée des calculs de dose. Enfin, deux algorithmes DL prédictifs de dose à plusieurs sources ont été validés pour la curiethérapie prostatique LDR. Les données de référence prenaient en compte les effets d'atténuation entre les sources et une définition des matériaux basée sur les organes du patient. De plus, les incertitudes aléatoires (associées aux données d'entrée) et épistémiques (associées au modèle) des modèles DL ont été évaluées. Les résultats ont montré que la métrique D$_{90}$ de la prostate prédite présentait une différence de -0,64% et de 0,08% pour les modèles UNet et ResUNet TSE, respectivement. Les deux modèles DL prédisaient un volume de dose de 2,56 M de voxels (128×160×128) en 4 ms. L'incertitude dérivée est quantifiable et interprétable, mettant en évidence les régions où les modèles DL pourraient rencontrer des difficultés pour fournir des estimations précises de dose. L'analyse de l'incertitude est un outil précieux pour une évaluation approfondie, améliorant le processus d'évaluation des modèles de prédiction de dose. De plus, cette analyse fournit des informations critiques sur la performance du modèle, identifiant les domaines d'amélioration potentielle et garantissant une application plus fiable dans un contexte clinique. / Brachytherapy, a specialized form of cancer treatment, involves the placement of radioactive sources near or directly within the cancerous lesion. A critical aspect of this therapy is the calculation of radiation dose. Traditionally, this calculation relies on a water-based formalism, which does not adequately account for variations in patient tissue compositions and interseed effects in low-dose rate (LDR) brachytherapy. The Monte Carlo (MC) method is the gold standard for advanced dose calculations in brachytherapy, offering a solution to these limitations. However, the practical application of the MC method in treatment planning is hindered by its relatively slow execution time. This thesis explores the potential of deep learning (DL) methods to overcome this challenge. Specifically, it investigates the feasibility of using DL algorithms to accurately predict the volumetric dose distribution in LDR prostate brachytherapy patients, aiming to streamline the treatment planning process while maintaining the precision of dose calculations. Firstly, the TOPAS MC toolkit was systematically validated for brachytherapy simulations by comparing simulated results with published TG-186 reference data. The photon emission energy spectrum, the air-kerma strength, and the dose-rate constant of the MBDCA-WG generic $^{192}$Ir source were extracted. For dose calculations, a track-length estimator was implemented. The four Joint AAPM/ESTRO/ABG MBDCA-WG test cases were evaluated. A prostate, a palliative lung, and a breast case were simulated. The air-kerma strength and dose-rate constant were within 0.3% and 0.01% of the reference values, respectively. For all test cases, 96.9% of voxels had local dose differences within ±1%. On the other hand, the global dose difference histograms had 99.9% of voxels within ±0.1%. Dose-volume histograms of clinical cases were consistent with the reference data. Overall, TOPAS provides access to a state-of-the-art MC code for brachytherapy simulations. Secondly, a single-seed DL model trained with MC simulations as the gold standard was built to predict accurate single-seed dose to medium in medium (D$_\textup{M,M}$) distributions in LDR prostate brachytherapy. Existing knowledge was included in the network as an r$^2$ kernel related to the inverse of the first-order dose dependency in brachytherapy. DL model features showed an anisotropic representation that considered the patient organs and their interfaces, the source position, and the low- and high-dose regions. The predicted CTV D$_{90}$ metric had an average difference of -0.1% with respect to the MC-based calculation. The single-seed DL model takes 1.8 ms to predict a complete 3D D$_\textup{M,M}$ volume of 1.18 M voxels. The proposed DL model represents a streamlined and rapid computational engine, incorporating pre-existing physics knowledge pertinent to brachytherapy. This engine is designed to consider the anisotropic characteristics of a brachytherapy source and the specific composition of patient tissues, ensuring an accurate, fast, and tailored approach to dose calculations. Lastly, two multi-seed DL-based predictive dose algorithms were trained for LDR prostate brachytherapy. Ground truth data considered interseed effects and an organ-based material assignment. Additionally, the aleatoric (associated with the input data) and epistemic (associated with the model) uncertainties of the DL models were assessed. Results showed that the predicted prostate D$_{90}$ metric had a difference of -0.64% and 0.08% for the UNet and ResUNet TSE models, respectively. Both DL models predicted a 3D dose volume of 2.56 M voxels (128×160×128) in 4 ms. The derived uncertainty is quantifiable and interpretable, highlighting regions where DL models might face challenges in delivering precise dose estimations. The uncertainty analysis is a valuable tool for a thorough evaluation, enhancing the assessment process of the dose prediction models. This analysis provides critical insights into the model's performance, pinpointing areas for potential improvement and ensuring a more reliable application in clinical settings.
37

Etudes expérimentales et modélisations Monte Carlo de l'auto-absorption gamma et de la dosimétrie active par capteurs CMOS

Nachab, Abdellatif 13 December 2003 (has links) (PDF)
Les travaux de recherche de cette thèse portent sur deux parties: l'évaluation de l'auto-absorption des rayonnements gamma et l'étude de la fonction de réponse des capteurs à pixels actifs pour la dosimétrie en temps réel. Dans le processus d'analyse quantitative de la radioactivité par spectrométrie gamma, l'étalonnage en rendement de détection de la chaîne est une étape essentielle. Outre le problème des interférences, l'atténuation des photons dans l'échantillon et l'effet de sommation en cas de cascade de transitions gamma sont les deux principaux facteurs déterminants dans ce type d'analyse. Dans ce contexte des mesures expérimentales et des calculs de simulation Monte Carlo, ont été réalisés pour étudier le phénomène de la self-absorption et évaluer les effets de matrice dans le cas des échantillons volumineux. Cette étude a permis de corriger les analyses par spectrométrie gamma des phosphates marocains. La deuxième partie de la thèse consiste à appliquer des capteurs CMOS de type MIMOSA, dérivés de ceux développés par l'IReS et le LEPSI pour la physique des particules, à la détection de rayonnements de neutrons et alpha, pour en faire des dosimètres léectroniques impulsionnels personnels. Ces appareils doivent permettre de suivre en temps réel les concentations du radon dans des environnements variés. Des codes ont été élaborés pour l'acquisition et l'analyse des données enregistrées par un système conçu pour cette application. Des tests ont été effectués pour la détection du radon et descendants émanant d'une source de Radium. Les résultats de ces tests ont été comparés aux mesures obtenues par d'autres techniques passives et actives. Des calculs de simulation Monte Carlo de la fonction de réponse du système aux neutrons rapides à l'aide du code MCNP ont été effectués.
38

Etude expérimentale et modélisation Monte Carlo des grandeurs opérationnelles en métrologie des rayonnements ionisants : application à la dosimétrie neutrons par radiophotoluminescence / Experimental study and Monte Carlo modeling of operational quantities in metrology of ionizing radiation : application to neutrons dosimetry by radiophotoluminescence

Salem, Youbba Ould 09 September 2014 (has links)
Nous mettons au point un dosimètre passif capable de détecter les neutrons rapides et thermiques, destiné à la fois à la dosimétrie d'ambiance et personnelle. Ce dosimètre détecte les neutrons au moyen de convertisseurs appropriés (polyéthylène et cadmium). Cette étude s'est appuyée sur des simulations Monte Carlo, qui ont aidé à la conception géométrique du dosimètre et au choix des matériaux. La caractérisation expérimentale du dosimètre montre que les réponses à ces neutrons en termes de H*(10) et Hp(10) sont linéaires, avec des seuils de détection de 2 mSv pour les neutrons rapides et de 0, 19 mSv pour les neutrons thermiques. Les dépendances angulaires sont satisfaisantes selon les recommandations de la norme ISO 21909. Un facteur de calibration de (9,5 +- 0,5)x10 puissance -2 mSv.cm2/signal RPL a été obtenu pour les neutrons rapides de la source calibrée de 241Am-Be de l'IPHC. Ce facteur est de (9,7 +- 0,3)x10 puissance-3 mSv.cm2/signal RPL pour les neutrons thermalisés. / We characterize a passive dosimeter capable of measuring both fast and thermal neutrons for ambiant and persona! dosimetry. These neutrons can be detected in a mixed neutron-gamma field with appropriate converters (polyethylene for fast neutrons, cadmium for thermal neutrons). Monte Carlo simulations with MCNPX helped with the geometrical conception of the dosimeter and the choice of materials. The responses of the RPL dosimeter to these neutrons are linear in H*(1 O) and Hp(10) with detection limits of 2 mSv for fast neutrons and 0.19 mSv for thermal neutrons. The angular dependencies are satisfactory according to the ISO 21909 norm. A calibration factor of (9.5 +- 0.5)x10 exponent -2 mSv.cm2/RPL signal is obtained to the fast neutrons of the IPHC's 241 Am-Be calibrator. This factor is (9.7 +- 0.3)x10 exponent -3 mSv.cm2/RPL signal for the thermalized neutrons.
39

Simulation Monte Carlo GATE et dosimétrie en radiothérapie peropératoire pour le cancer du sein / GATE Monte Carlo simulation and dosimetry in intra-operative radiation therapy for breast cancer

Bouzid, Dounia 20 November 2015 (has links)
La radiothérapie externe représente une part importante du traitement conservateur du sein. Le calendrier classique consiste à délivrer une dose totale de 50 Gy en 25 fractions sur 5 semaines. Pour certaines catégories de femmes, une radiothérapie de 5 à 6 semaines, avec des transports longs et fréquents est parfois difficile à réaliser. La radiothérapie peropératoire (RIOP) permet de prévenir le risque de récidive locale dans le lit tumoral, et ne nécessite que quelques jours d’hospitalisation. Cette étude se concentre sur l’utilisation d'une source de rayons X miniaturisée de faible énergie (50kV). Après résection chirurgicale de la tumeur, un applicateur est inséré dans le lit tumoral et le système délivre une dose unique de 20 Gy à sa surface. Cependant, il n'y a pas de prescription personnalisée ni d'information sur la dose délivrée et ce point est contestable, car un texte officiel recommande une optimisation de la dose individuelle. Dans ce contexte, un calcul Monte Carlo permet d'évaluer avec précision la dose délivrée à la patiente en simulant le transport des particules. Cette thèse propose d'évaluer ce critère de dose absorbée le plus justement possible à partir d'une modélisation réaliste de la source de rayons X et de calculs de dose individuels à l'aide de simulations de Monte Carlo en prenant en compte les hétérogénéités tissulaires du sein. Des mesures dosimétriques in vivo viennent également confirmer les résultats de simulations. / External radiation therapy is an important part of breast conservative treatment. The conventional calendar is to deliver a total dose of 50 Gy in 25 fractions over 5 weeks. For certain categories of women, 5 to 6 weeks of radiotherapy, with long and frequent transport is sometimes difficult to achieve. Intra-operative radiotherapy (IORT) helps to prevent the risk of local recurrence in the tumor bed, and only requires a few days of hospitalization. This study focuses on the use of a miniaturized low energy X-ray source (50kV). After surgical resection of the tumor, an applicator is inserted into the tumor bed and the system delivers a single dose of 20 Gy on its surface. However, there is no custom prescription and this is questionable since an official text recommends optimizing the individual dose. In this context, a Monte Carlo calculation makes it possible to accurately assess the dose delivered to the patient by simulating the transport of particles. This thesis proposes to assess the absorbed dose criterion as accurately as possible from a realistic model of the X-ray source and individual dose calculations using Monte Carlo simulations taking into account the tissue heterogeneities of the breast. In vivo dosimetric measurements also confirm the results of simulations.
40

Le 4-fluoro-11[bêta]-méthoxy-[[indice supérieur 18]F]fluoroestradiol (4FMFES) pour l'imagerie des récepteurs d'oestrogènes par tomographie par émission de positrons

Beauregard, Jean-Mathieu January 2008 (has links)
La majorité des cancers du sein surexpriment des récepteurs d'oestrogènes (RO) et/ou de progestérone. Connaître le statut en RO est primordial pour déterminer le meilleur traitement à offrir aux patientes. Ce statut est habituellement déterminé par biopsie, une technique invasive et limitée aux sites accessibles, en plus d'être sujette à l'hétérogénéité de l'expression des RO au sein d'une même lésion tumorale et entre les lésions (lésion primaire et métastases). L'imagerie des RO est une alternative non-invasive pour déterminer in vivo le statut en RO des tumeurs. Parmi les nombreux traceurs des RO radiomarqués développés durant les 3 dernières décennies, le 16[alpha]-[[indice supérieur 18]F]-fluoroestradiol (FES), un traceur pour la tomographie par émission de positrons (TEP), est celui ayant connu le plus de succès. Cependant, il est métabolisé rapidement in vivo, ce qui limite son accumulation optimale au niveau des tumeurs exprimant les RO (RO+). Parmi une série de nouveaux traceurs des RO, le 4-fluoro-11[bêta]-méthoxy-16[alpha]-[[indice supérieur 18]F]fluoroestradiol (4FMFES) a démontré des résultats précliniques prometteurs. Comparativement au FES, le 4FMFES à une très faible affinité pour la sex hormone-binding globulin (SHBG). Certains auteurs ont suggéré qu'une bonne affinité pour la SHBG est souhaitable en imagerie des RO chez l'humain. L'activité spécifique effective (ASE), ou la quantité de radioactivité par quantité de masse biologiquement active, est un paramètre important en imagerie des RO, un système saturable. Dans nos expériences de saturation in vivo chez la souris, un effet de masse fut observé au niveau de l'utérus et de tumeurs murines RO+ implantées à partir d'une masse équivalente d'estradiol d'environ 100 pmol. Nous avons développé une méthode simple et efficace pour mesurer de routine l'ASE des traceurs des RO, qui utilise la scintillation par proximité lors d'un essai compétitif de liaison sur des RO purifiés. Nous avons évalué la biodistribution et la dosimétrie du 4FMFES lors d'une étude de phase I chez dix femmes saines. Après avoir été injecté avec du 4FMFES, chaque participante a subi 4 acquisitions TEP rapides sériées, couplées à 2 acquisitions tomodensitométriques (TDM) à faible dose, durant 2 heures, sur une caméra TEP/TDM. Le logiciel OLINDA fut utilisé pour calculer les courbes temps-activité, les temps de résidence et la dosimétrie. L'activité sanguine et plasmatique fut mesurée par des prises de sang sériées.La sûreté du 4FMFES a été évaluée par le monitoring des signes vitaux et de certains paramètres sanguins et urinaires. Le 4FMFES fut bien toléré chez toutes les participantes. Le foie a démontré une captation intense, associée à une excrétion hépatobiliaire massive, et relativement peu d'excrétion urinaire. Les demi-vies de clairance de l'activité sanguine et plasmatique, entre 30-150 minutes post-injection, étaient d'environ 110 minutes.La captation utérine fut visualisée chez toutes les participantes et est demeurée relativement constante en fonction du temps. L'activité de bruit de fond était faible et décroissante en fonction du temps, résultant en un ratio utérus-sur-bruit croissant. L'organe critique fut la vésicule biliaire (0.80 « 0.51 mGy/MBq), suivie par le côlon proximal, l'intestin grêle et le foie. Pour une dose typique de 185 MBq, la dose effective (DE) fut calculée à 4.82 « 0.70 mSv. Le 4FMFES est considéré sécuritaire pour usage chez l'humain et sa DE demeure dans des limites acceptables. Le 4FMFES a démontré une captation utérine significative tant chez les participantes préménopausées que ménopausées, qui est probablement médiée par les RO, i.e. spécifique. Aussi, ces résultats suggèrent que la liaison à la SHBG n'est pas nécessaire pour imager les RO in vivo chez l'humain. Une comparaison directe entre le FES et le 4FMFES chez des patientes atteintes du cancer du sein sera nécessaire pour déterminer quel est le traceur optimal pour l'imagerie TEP des RO.