• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 120
  • 23
  • 12
  • Tagged with
  • 156
  • 64
  • 64
  • 49
  • 49
  • 32
  • 30
  • 28
  • 27
  • 20
  • 19
  • 18
  • 18
  • 17
  • 16
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Quantification en thérapie radionucléique par radiopeptides au 177 Lu

Frezza, Andrea 27 January 2024 (has links)
Le présent travail de thèse concerne la quantification en imagerie moléculaire en trois dimensions (3D), en particulier, dans le cadre de la thérapie radionucléique par radiopeptides (TRRP) au ¹⁷⁷Lu pour les tumeurs neuroendocrines (TNE). Le ¹⁷⁷Lu est un radioisotope émetteur beta, à courte portée dans les tissus (2 mm), et gamma, avec des énergies utilisables pour l'imagerie de tomographie par émission mono-photonique (TEM). Ces caractéristiques font de celui-ci un bon radioisotope pour la TRRP des TNE : de petite taille et répandues dans le corps. De plus, avec plusieurs images de TEM prises lors d'un traitement, il est possible de quantifier la distribution du radioisotope dans le corps du patient et même d'évaluer la progression du traitement. L'objectif principal du projet est le développement et la validation des outils, expérimentaux et informatiques, pour la quantification de la dose absorbée lors d'une TRRP au ¹⁷⁷Lu, avec la possibilité d'étendre les méthodes à d'autres radioisotopes. Deux étapes principales ont été nécessaires. La première était la calibration et la caractérisation de l'appareil d'imagerie de TEM. Dans ce contexte, plusieurs techniques d'acquisitions et d'analyse ont été testées et un protocole de calibration simplifié a été proposé. Un accent particulier est mis sur la détermination du facteur de calibration (CF) et du temps mort (τ ) de l'appareil de TEM pour la correction et la quantification des images acquises. D'une évaluation de l'équation qui gouverne le comportement de détection de l'appareil de TEM, une nouvelle formulation plus concise et analysable mathématiquement a été proposée. Celle-ci permet l'extraction des deux facteurs de façon approximative, mais simple ainsi que la proposition d'un nouveau protocole de calibration. Avec des images bien quantifiées en activité (biodistribution du radiopeptide dans le corps), il est possible, par simulations Monte Carlo (MC), de calculer le dépôt de dose. Une deuxième étape a été la validation du code irtGPUMCD. Il s'agit d'un code MC, fonctionnant sur processeur graphique (GPU), pour le calcul de la dose absorbée lors d'une TRRP et précédemment développé au sein du Groupe de recherche en physique médicale du CHU de Québec - Université Laval. Le code irtGPUMCD a été adapté pour l'utilisation dans des conditions standard et validé sur les modèles informatiques de la International Commission on Radiological Protection (ICRP110), non seulement pour le ¹⁷⁷Lu, mais aussi pour le ¹³¹I et ⁹⁹ᵐTc. Avec les simulations exécutées sur une géométrie de référence et une comparaison avec d'autres résultats présents en littérature, le code a été validé. Dans le cadre de l'optimisation en termes de temps et exactitude des résultats fournis par irtGPUMCD, un algorithme de traçage de rayons (raytracing) ainsi qu'une technique de réduction de variance ont été implémentés, testés et validés. Ces changements de code ont permis une réduction d'un facteur dix du temps de calcul pour une simulation. Les images/cartes de dose absorbée tridimensionnelle bien quantifiées donnent la possibilité de calculer les histogrammes dose-volume (DVH) et d'extraire toutes les informations dosimétriques intéressantes tel que fait dans d'autres branches de la radiothérapie. Une petite section de cette thèse est consacrée à la proposition de techniques statistiques, qui permettent, en associant les données dosimétriques avec celles du patient, de construire des modèles de probabilité de complication des tissus normaux (NTCP). Le principal impact de cette étude est l'introduction de toute une chaîne, bien validée, pour la quantification dans les TRRP. Avec une calibration adéquate de l'appareil d'imagerie de TEM et l'utilisation du code MC irtGPUMCD, il sera possible d'effectuer des études dosimétriques et statistiques plus avancées, par rapport à l'état de l'art en médicine nucléaire, et se diriger vers une personnalisation plus poussée des traitements. / The present thesis work concerns quantification in three-dimensional molecular imaging (3D), in particular, in the context of peptide receptor radionuclide therapy (PRRT) with ¹⁷⁷Lu for neuroendocrine tumors (NET). The ¹⁷⁷Lu is a beta emitting radioisotope, with short-range in tissue (2 mm), and gamma, with energies usable for single-photon emission computed tomography (SPECT) imaging. These characteristics make ¹⁷⁷Lu a good radioisotope for the PRRT of NETs: small and widespread in the body. In addition, with several SPECT images taken during a treatment, it is possible to quantify the distribution of the radioisotope in the patient body and assess the progress of the treatment itself. The main objective of the project is the development and validation of tools, experimental and computational, for the absorbed dose quantification during a ¹⁷⁷Lu PRRT, with the possibility to extend the methods to other radioisotopes. Two main steps were necessary. The first step was the calibration and characterization of the SPECT imaging device. In this context, several acquisition and analysis techniques were tested and a simple calibration protocol was proposed. Particular emphasis is given to the determination of the calibration factor (CF) and dead time (τ ) constant of the SPECT device for the correction and quantification of the acquired images. From an evaluation of the equation describing the behavior of the SPECT system, a new, more concise and mathematically tractable formulation has been proposed. This formulation allows the extraction of the two factors in an approximate but simple way as well as the proposal of a new calibration protocol. With well-quantified images in activity (bio-distribution of the radio-peptide in the body) it is possible to calculate the dose deposition by Monte Carlo simulations (MC). A second step was the validation of the irtGPUMCD code. It is a MC code, operating on a graphics processing unit (GPU), previously developed within the Research Group in Medical Physics of the CHU de Québec, which allows the calculation of the absorbed dose received during a PRRT. The irtGPUMCD code has been used and validated under standard conditions with International Commission on Radiological Protection (ICRP110) phantoms, not only for the ¹⁷⁷Lu, but also for the ¹³¹I and ⁹⁹ᵐT c. With the simulations performed on a referenced geometry and with a comparison to other results present in literature, the code was validated. In the context of the optimization in time and accuracy of the results provided by irtGPUMCD, a new raytracing algorithm and a variance reduction technique were introduced, tested and validated. These code changes have led to a reduction in execution time of a factor ten for a simulations. The well quantified three-dimensional absorbed dose images/maps give the possibility of calculating dose-volume histograms (DVH) and extracting all the dosimetric information of interest as done in other branches of radiotherapy. A small part of this thesis is dedicated to the proposal of statistical techniques, which allow, by linking the dosimetric data with patient outcomes, to build models of normal tissues complication probability (NTCP). The main impact of this study is the introduction of a whole chain, well validated, for the quantification in PRRT. With an accurate calibration of the SPECT imaging system and the use of the irtGPUMCD MC code, it will be possible to carry out more advanced dosimetric and statistical studies, compared to the state of the art in nuclear medicine, and to head towards a more personalized treatment.
72

Conception d'un formalisme de pouvoir d'arrêt équivalent et accélération graphique : des simulations Monte Carlo plus efficaces en protonthérapie

Maneval, Daniel 27 April 2019 (has links)
En radiothérapie, la planification de traitement correspond à l’optimisation de la balistique pour administrer la dose prescrite aux lésions à traiter, tout en minimisant les doses collatérales reçues par les tissus sains. L’algorithme de calcul de dose qui est au cœur de cette simulation numérique se doit d’être précis et efficace. L’antagonisme de ces deux compétences a abouti au développement d’algorithmes analytique rapides dont l’amélioration de la précision dosimétrique a, de nos jours, atteint sa limite. L’exactitude de l’algorithme de calcul de dose est particulièrement importante en protonthérapie pour exploiter pleinement le potentiel balistique des protons. La méthode Monte Carlo de transport de proton est la plus précise mais également la moins efficace. Cette thèse a pour sujet le développement d’une plateforme Monte Carlo de calcul de dose suffisamment efficace pour envisager son utilisation en routine clinique. L’objectif principal du projet est d’accélérer le transport Monte Carlo de protons sans compromettre la précision des dépôts de dose. Pour ce faire, deux voies de recherche ont été exploitées. La première a consisté à établir une nouvelle méthode de réduction de variance nommée formalisme du pouvoir d’arrêt restreint équivalent (formalisme Leq). Cette technique améliore significativement la complexité algorithmique temporelle rendue constante (O(1)) au lieu de linéaire (O(n)) des algorithmes Monte Carlo actuels. La seconde voie de recherche s’est attardée à l’utilisation des processeurs graphiques pour améliorer la vitesse d’exécution du transport Monte Carlo de protons. La plateforme développée, nommée pGPUMCD, réalise le transport des protons sur des processeurs graphiques au sein de géométries voxelisées. Dans pGPUMCD, les techniques d’interactions condensées et ponctuelles sont considérées. Les interactions inélastiques de faibles portées sont modélisées par la décélération continue du proton à l’aide du formalisme Leq, et les interactions élastiques par la diffusion coulombienne multiple. Les interactions ponctuelles modélisées sont les interactions inélastiques, les intéractions nucléaires élastiques et non-élastiques proton-noyaux. pGPUMCD est comparé à Geant4, et les procédés physiques implémentés sont validés les uns après les autres. Pour les cas cliniques de calcul de dose, 27 matériaux sont définis pour la segmentation des tissus du scanner tomodensitométrique. L’exactitude dosimétrique du formalisme Leq est meilleure que 0.31% pour divers milieux allant de l’eau à l’or. Les gains d’efficacité intrinsèque au formalisme Leq sont supérieurs à 30 : entre 100 et 630 à précisions dosimétriques similaires. Combiné à l’accélération du GPU, le gain d’efficacité est d’un ordre de grandeur supérieur à 10⁵. pGPUMCD concorde à Geant4 à moins de 1% jusqu’au pic de Bragg et à moins de 3% dans sa pénombre distale, pour différentes configurations de simulations allant des milieux homogènes jusqu’aux cas cliniques. De plus, 99.5% des points de dose passent le critère 1% et les portées de prescription concordent avec celles de Geant4 à moins 0.1%. Les temps de calcul de pGPUMCD sont inférieurs à 0.5 seconde par million de protons transportés contre plusieurs heures avec Geant4. Les performances dosimétriques et d’efficacité de pGPUMCD lui confèrent les bonnes caractéristiques pour être employé dans un environnement de planification dosimétrique clinique. L’apport médical attendu est un meilleur contrôle sur les doses administrées, ce qui permet une réduction significative des marges et des toxicités des traitements. / In radiotherapy, treatment planning is the optimization of the ballistics to administer the prescribed dose to the treated lesions while minimizing collateral doses received by the healthy tissue. The algorithm of the dose calculation is at the heart of this numerical simulation. It must be precise and computationally efficient. The antagonism of these two features has led to the development of rapid analytical algorithms whose improvement in dosimetric accuracy has nowadays reached its limit. The accuracy of the dose calculation algorithm is particularly important in proton therapy to fully exploit the ballistic potential of protons. The Monte Carlo proton transport method is the most accurate but also the least efficient. This thesis deals with the development of a Monte Carlo dose calculation platform that is sufficiently effective to consider its use in clinical routine. The main objective of the project is to accelerate the Monte Carlo proton transport without compromising the precision of the dose deposition. To do this, two lines of research have been exploited. The first was to establish a new variance reduction technique called the equivalent restricted stopping power formalism (formalism Leq). This technique significantly improves the algorithmic time complexity made constant (O(1)) instead of linear (O(n)) for the current Monte Carlo algorithms. The second line of research focused on the use of graphics processing units to improve the execution speed of the proton Monte Carlo transport. The developed platform, named pGPUMCD, transports protons on graphic processors in a voxelized geometry. In pGPUMCD, condensed and discrete interaction techniques are considered. The inelastic low-range interactions are modeled with a continuous proton slowing down using the Leq formalism and the energy straggling is considered. The elastic interactions are based on the multiple Coulomb scattering. The discrete interactions are the inelastic interactions, the nuclear elastic and the non-elastic proton-nuclei interactions. pGPUMCD is compared to Geant4 and the implemented physical processes are validated one after the other. For the dose calculation in a clinical context, 27 materials are defined for the tissue segmentation from the CT scan. The dosimetric accuracy of the Leq formalism is better than 0.31% for various materials ranging from water to gold. The intrinsic efficiency gain factors of the Leq formalism are greater than 30, between 100 to 630 for a similar dosimetric accuracy. Combined with the GPU acceleration, the efficiency gain is an order of magnitude greater than 10⁵. Dose differences between pGPUMCD and Geant4 are smaller than 1% in the Bragg peak region and below 3% in its distal fall-off for the different simulation configurations with homogeneous phantoms and clinical cases. In addition, 99.5% of the dose points pass the criterion 1% and the prescribing ranges match with those of Geant4 at less than 0.1%. The computing times of pGPUMCD are below 0.5 seconds per million of transported protons compared to several hours with Geant4. The dosimetric and efficiency performances of pGPUMCD make it a good candidate to be used in a clinical dosimetric planning environment. The expected medical benefit is a better control of the delivered doses allowing a significant margin and toxicity reductions of the treatments.
73

Conception et caractérisation d'un dosimètre à fibre scintillante pour des applications en imagerie diagnostique et interventionnelle

Boivin, Jonathan 24 April 2018 (has links)
Cette thèse a pour sujet le développement d’un détecteur à fibre scintillante plastique pour la dosimétrie des faisceaux de photons de basses énergies. L’objectif principal du projet consiste à concevoir et caractériser cet instrument en vue de mesurer la dose de radiation reçue au cours des examens d’imagerie diagnostique et interventionnelle. La première section est consacrée à la conception de six différents systèmes et à l’évaluation de leur performance lorsqu’ils sont exposés à des rayonnements de hautes et basses énergies. Tous les systèmes évalués présentaient un écart type relatif (RSD) de moins de 5 % lorsqu’ils étaient exposés à des débits de dose de plus de 3 mGy/s. Cette approche systématique a permis de déterminer que le tube photomultiplicateur répondait le mieux aux conditions d’exposition propres à la radiologie. Ce dernier présentait une RSD de moins de 1 % lorsque le débit de dose était inférieur à 0.10 mGy/s. L’étude des résultats permis également de suggérer quelques recommandations dans le choix d’un système en fonction de l’application recherchée. La seconde partie concerne l’application de ce détecteur à la radiologie interventionnelle en procédant à des mesures de dose à la surface d’un fantôme anthropomorphique. Ainsi, plusieurs situations cliniques ont été reproduites afin d’observer la précision et la fiabilité du détecteur. Ce dernier conserva une RSD inférieure à 2 % lorsque le débit de dose était supérieur à 3 mGy/min et d’environ 10 % au débit le plus faible (0.25 mGy/min). Les mesures sur fantôme montrèrent une différence de moins de 4 % entre les mesures du détecteur et celles d’une chambre d’ionisation lors du déplacement de la table ou du bras de l’appareil de fluoroscopie. Par ailleurs, cette différence est demeurée sous les 2 % lors des mesures de débit de dose en profondeur. Le dernier sujet de cette thèse porta sur les fondements physiques de la scintillation dans les scintillateurs plastiques. Les différents facteurs influençant l’émission lumineuse ont été analysés afin d’identifier leur contribution respective. Ainsi, la réponse du détecteur augmente de près d’un facteur 4 entre un faisceau de 20 kVp et 250 kVp. De ce signal, la contribution de la fluorescence produite dans la fibre claire était inférieure à 0.5 % lorsque les fibres étaient exposées sur 10 cm par des faisceaux de 20 à 250 kVp. Le phénomène d’extinction de la fluorescence par ionisation a également été étudié. Ainsi, l’atténuation du signal variait en fonction de l’énergie du faisceau et atteignit environ 20 % pour un faisceau de 20 kVp. En conclusion, cette étude suggère que les détecteurs à fibres scintillantes peuvent mesurer avec précision la dose de radiation reçue en imagerie diagnostique et interventionnelle, mais une calibration rigoureuse s’avère essentielle. / This thesis deals with the development of a plastic scintillation detector for low energy photon eams. The main goal of the project consists in the design and characterization of this tool in the aim of measuring the radiation dose involved during diagnostic and interventional radiology examinations. The first section is devoted to the design of six different systems and to their performance evaluation when they are exposed to high and low energy radiation. For all photodetectors, the relative standard deviation (RSD) was less than 5% for dose rates higher than 3 mGy/s. This systematic approach identified the photomultiplier tube as the most appropriate photodetector for radiology specific beam qualities. Indeed, its RSD was less than 1% when the dose rate was below 0.10 mGy/s. The result analysis allowed the suggestion of some guidelines for the selection of an appropriate detector for a specific application. The second part was about this detector application to interventional radiology procedures by performing dose measurements at an anthropomorphic phantom surface. Several clinically relevant setups were reproduced to observe the detector’s accuracy and reliability. The RSD remained under 2% when the dose rate was more than 3 mGy/min and about 10% at the lowest dose rate (0.25 mGy/min). Phantom measurements showed a dose rate difference between the detector and the ion chamber of less than 4% when moving the table’s height or rotating the fluoroscope gantry. Moreover, this difference was below 2% for depth dose rate measurements. The last subject of this thesis was about the fundamental physics of scintillation within the plastic scintillators. The factors affecting the light emission were analyzed in order to identify their respective contribution. The detector’s response increased by a factor of about 4 when the tube potential varied between 20 kVp and 250 kVp. The clear optical response was below 0.5%of the scintillator’s light when the fibers were exposed on 10 cm-long by these beam qualities. he ionization quenching phenomenon was also investigated. The signal attenuation varied with the beam energy and reached about 20% for a 20 kVp beam quality. In conclusion, this study suggests that the plastic scintillation detectors can accurately measure the radiation dose involved in diagnostic and interventional radiology, but a rigorous calibration is essential.
74

Conception d'un détecteur à scintillateur plastique pour les mesures dosimétriques en petits champs de radiation

Morin, Jonathan 19 April 2018 (has links)
La radiochirurgie stéréotaxique consiste à irradier une petite zone cérébrale à l'aide d'un champ de radiation de très petite dimension. Contrairement à la radiothérapie externe conventionnelle, les tissus sains sont épargnés par l'amélioration géométrique de la conformité de dose plutôt que par fractionnement du traitement. L'utilisation de collimateurs très atténuant et d'un système de stéréotaxie permettent d'obtenir la conformité de dose et la précision spatiale nécessaires pour ce type de traitement. Par contre, de telles conditions d'irradiation engendrent l'addition de défis dosimétriques supplémentaires. À ce jour, aucun dosimètre ne possède toutes les propriétés nécessaires pour la mesure de dose en petits champs, que ce soit au niveau du volume sensible trop important, de la non équivalence à l'eau, de la dépendance angulaire ou sur le débit de dose. Nous proposons les détecteurs à scintillateur plastique à titre de référence pour la dosimétrie en petits champs, car ils possèdent plusieurs avantages très attrayants vis-à-vis la radiochirurgie stéréotaxique. Deux détecteurs ont donc été développés ayant des volumes sensibles cylindriques de 0.5 et 1.0 mm de diamètre ainsi qu'une longueur de 1.0 mm. Ceux-ci ont été comparés à plusieurs dosimètres commerciaux de radiochirurgie, soit la chambre à ionisation A-16, la diode SFD, la diode blindée 60008, la diode non blindée 60012 et la chambre à ionisation liquide (MicroLion). Pour ce faire, des facteurs de cône ont été mesurés sur un appareil CyberKnife. Pour évaluer la performance de chacun des détecteurs par rapport à l'eau, ces mesures ont été comparées à deux études Monte Carlo indépendantes. Finalement, des profils de dose ont été mesurés avec les deux détecteurs développés, une diode 60012 et des Gafchromics EBT2 pour vérifier si les propriétés des différents détecteurs créent des erreurs significatives sur ce type de mesure.
75

Calcul de dose avec images de tomographie à faisceau mégavoltage conique pour le développement de la radiothérapie guidée par la dose

Aubry, Jean-François 16 April 2018 (has links)
L'imagerie mégavoltage à faisceau conique (MVCBCT) est une technique de tomographie qui permet d'obtenir des images 3D d'un patient quelques instants avant son irradiation. Le présent projet se consacre à cette technologie et est bâti en trois étages superposés: d'abord une étude des caractéristiques du système d'imagerie et des images qu'il produit, suivi du développement de méthodes de correction des images permettant un calcul de dose exact, pour terminer avec quelques applications cliniques adhérant au principe de radiothérapie guidée par la dose (DG RT). Les images MVCBCT présentent invariablement un artéfact en creux, caractérisé par une diminution de l'intensité au centre de l'image et causant des erreurs de calcul de dose allant facilement jusqu'à 10%. L'étude du système MVCBCT, réalisée à partir de simulations Monte Carlo, conclut que l'artéfact en creux est majoritairement dû à l'adoucissement radial et au duricissement en pronfondeur du faisceau de photons. Deux méthodes de correction de l' artéfact en creux ont été développées, l'une pour les images de la région ORL (tête et cou), l'autre pour les images pelviennes. L'algorithme de correction d'images ORL met à profit l'information contenue dans l'image CT de planification pour rétablir les densités sur l'image MVCBCT. Le traitement des images pelviennes est quant à lui basé sur des facteurs de correction obtenus à partir de mesures sur différents fantômes anthropomorphiques. Ces deux méthodes permettent de réduire l'incertitude des calculs de dose à partir d'images MVCBCT à ±3%. Enfin, une étude de recalcul de dose pour un nombre de cas d'ORL et de prostate a été menée à l'aide d'images MVCBCT acquises au début de plusieurs fractions du traitement. Cette étude confirme que les patients recoivent la dose prescrite au volume cible, sauf pour une fraction d'un cas de prostate où une erreur de positionnement n'a pas été détectée sur le fait. Il a aussi été révélé que la dose moyenne aux glandes parotides des patients ORL peut augmenter jusqu'à 50% au cours du traitement. D'importantes variations dans la dose par fraction reçue par le rectum et la vessie ont aussi été remarquées pour les cas de prostate. Des stratégies d'adaptation des plans de traitement évitant une replanification totale n'ont pu permettre de rétablir les valeurs dosimétriques originales chez les patients ORL.
76

Development and evaluation of low-dose rate radioactive gold nanoparticles for application in nanobrachytherapy

Laprise-Pelletier, Myriam 14 March 2024 (has links)
Depuis les dix dernières années, l’innovation des traitements d’oncologie a fait une utilisation croissante de la nanotechnologie. De nouveaux traitements à base de nanoparticules (NPs) sont notamment rendus au stade de l’essai clinique. Possédant des caractéristiques physico-chimiques particulières, les NPs peuvent être utilisées afin de bonifier l’effet thérapeutique des traitements actuels. Par exemple, l’amélioration de la curiethérapie (c.-à-d. radiothérapie interne) nécessite le développement de nouvelles procédures permettant de diminuer la taille des implants, et ce, tout en augmentant l’homogénéité de la dose déposée dans les tumeurs. Des études théoriques et expérimentales ont démontré que l’injection de NPs d’or à proximité des implants traditionnels de curiethérapie de faible débit de dose (par ex. 125I, 103Pd) permettrait d’augmenter significativement leur efficacité thérapeutique. L'interaction entre l’or et les photons émis par les implants de curiethérapie (c.-à-d. l’effet de radiosensibilisation) génère des rayonnements divers (photoélectrons, électrons Auger, rayons X caractéristiques) qui augmentent significativement la dose administrée. Dans le cadre de cette thèse, l’approche proposée était de développer des NPs d’or radioactives comme nouveau traitement de curiethérapie contre le cancer de la prostate. L’aspect novateur et unique était de synthétiser une particule coeurcoquille (Pd@Au) en utilisant l’isotope actuellement employé en curiethérapie de la prostate: le palladium-103 (103Pd, 20 keV). Dans ce cas-ci, la présence d’atomes d’or permet de produire l’effet de radiosensibilisation et d’augmenter la dose déposée. La preuve de concept a été démontrée par la synthèse et la caractérisation des NPs 103Pd@Au-PEG NPs. Ensuite, une étude longitudinale in vivo impliquant l’injection des NPs dans un modèle xénogreffe de tumeurs de la prostate chez la souris a été effectuée. L’efficacité thérapeutique induite par les NPs a été démontrée par le retard de la croissance tumorale des souris injectées par rapport aux souris non injectées (contrôles). Enfin, une étude de cartographie de la dose générée par les NPs à l’échelle cellulaire et tumorale a permis de comprendre davantage les mécanismes thérapeutiques liés aux NPs radioactives. En résumé, l’ensemble des travaux présentés dans cette thèse font office de précurseurs relativement au domaine de la nanocuriethérapie, et pourraient ouvrir la voie à une nouvelle génération de NPs pour la radiothérapie. / The last decade saw the emergence of new innovative oncology treatments based on nanotechnology. New treatments using nanoparticles (NPs) are now translated to clinical trials. NPs possess unique physical and chemical properties that can be advantageously used to improve the therapeutic effect of current treatments. For instance, therapeutic efficiency enhancement related to internal radiotherapy (i.e., brachytherapy), requires the development of new procedures leading to a decrease of the implant size, while increasing the dose homogeneity and distribution in tumors. Several theoretical and experimental studies based on low-dose brachytherapy seeds (e.g., 125I and 103Pd) combined with gold nanoparticles (Au NPs) showed very promising results in terms of dose enhancement. Gold is a radiosensitizer that enhances the efficiency of radiotherapy by increasing the energy deposition in the surrounding tissues. Dose enhancement is caused by the photoelectric products (photoelectrons, Auger electrons, characteristic X-rays) that are generated after the irradiation of Au NPs. In this thesis, the proposed approach was to develop radioactive Au NPs as a new brachytherapy treatment for prostate cancer. The unique and innovative aspect of this strategy was to synthesize core-shell NPs based on the radioisotope palladium-103 (103Pd, 20 keV), which is currently used in low-dose rate prostate cancer brachytherapy. In this concept, the administrated dose is increased via the radiosensitization effect that is generated through the interactions of low-energy photons with the gold atoms. The proof-ofconcept of this approach was first demonstrated by the synthesis and characterization of the core-shell NPs (103Pd@Au-PEG NPs). Then, a longitudinal in vivo study following the injection of NPs in a prostate cancer xenograft murine model was performed. The therapeutic efficiency was confirmed by the tumor growth delay of the treated group as compared to the control group (untreated). Finally, a mapping study of the dose distribution generated by the NPs at the cellular and tumor levels provided new insights about the therapeutic mechanisms related to radioactive NPs. In summary, the studies presented in this thesis are precursors works in the field of nanobrachytherapy, and could pave the way for a new generation of NPs for radiotherapy.
77

L'utilisation de marges personnalisées dans le traitement du cancer du poumon en radiothérapie

Germain, François 12 April 2018 (has links)
L’utilisation de marges personnalisées dans le traitement du cancer du poumon en radiothérapie : analyse des mouvements physiologiques et des impacts dosimétriques OBJECTIFS : Le but de cette étude est d’analyser les mouvements physiologiques et leurs impacts dosimétriques lors de la planification de traitements en radiothérapie par tomodensitométrie thoracique (TDM). MÉTHODES : Il s’agit d’une étude de 15 patients. Des plans de radiothérapie conforme tridimensionnelle (3D-CRT) ont été utilisés. Un plan de référence a été fait et comparé à des plans utilisant des marges personnalisées (obtenue par 5 TDM). Des analyses volumétriques et dosimétriques ont été faites. RÉSULTATS : Les volumes obtenus progressent rapidement avec la fusion de TDM. Lorsqu’une couverture semblable est obtenue, le volume cible est moindre et l’irradiation pulmonaire est discrètement réduite. CONCLUSION : Malgré les avantages d’une marge personnalisée, elle ne produit qu’un avantage clinique limité. Toutes les techniques augmentant le volume total pour inclure les mouvements devraient en venir à des conclusions semblables. / Individualized margins in radiotherapy planning of lung cancer: analysis of physiological movements and their dosimetric impacts OBJECTIVE: This study is an analysis of physiological movements and their dosimetric impacts when a single thoracic CT-scan is used for treatment planning purposes in radiation oncology. METHODS: This is a study of 15 patients. Three-dimensional conformal radiation therapy was (3D-CRT) was used. A reference clinical plan was constructed and compared with plans using individualized margins (obtained by using five CT-scans). Volumetric and dosimetric analyses were made for each. RESULTS: The total volume occupied by GTV progressed quickly with the fusion of CT-scans. For a similar coverage, target volume was smaller and lung irradiation was slightly decreased. CONCLUSIONS: Even if the individualized margin was used, it produced a limited clinical advantage. All techniques that increase total volume with an aim to include more movements should come to similar conclusions.
78

Irradiation corporelle totale dynamique à vitesse variable : de la planification au traitement

Lavallée, Marie-Claude 17 April 2018 (has links)
Le but de cette thèse est de proposer des solutions aux diverses lacunes de la technique d'irradiation corporelle totale (TBI) dynamique à vitesse variable. Le premier aspect étudié est la protection des organes à risque par des atténuateurs de plomb. La couverture de ces derniers a d'abord été caractérisée, puis une proposition de design a été faite afin de pallier aux lacunes engendrées par l'aspect dynamique de la technique. Ensuite le calcul de la dose et la planification du traitement ont été étudiés. Le calcul de la dose a d'abord été intégré dans le logiciel Pinnacle³, afin de permettre un calcul réaliste en milieu homogène ou hétérogène. Deux approches de modélisation de la fluence de radiation ont été évaluées, soit une modélisation standard pour faisceaux conventionnels et une modélisation d'un faisceau spécifique adapté aux particularités de la technique TBI. Ensuite, les calculs de dose obtenus ont été comparés aux doses calculées par le logiciel de planification utilisé jusqu'à présent pour le calcul des TBI, soit Theraplan plus et un modèle de faisceau standard. Les résultats ont montré que le modèle spécifique au TBI dans Pinnacle³ permet un calcul de dose précis qui reproduit bien les caractéristiques du champ TBI et ses conditions particulières. Puisque Pinnacle³ permet aussi un calcul de dose hétérogène précis, une étude sur la distribution de dose dans tout le corps des patients a été conduite. Cette étude rétrospective réalisée sur 10 patients a permis de visualiser les distributions tridimensionnelles de dose et ainsi, de localiser les différentes régions de surdosages et de sous dosages comme par exemple, au niveau des os et des poumons. L'aspect de l'optimisation du traitement a ensuite été abordé, soit par l'évaluation de différentes approches comme l'optimisation sur des points de dose ou sur des volumes et l'optimisation à partir d'un calcul de dose homogène ou hétérogène. Finalement, le dernier aspect étudié est celui de la mesure de la dose in vivo. Les chambres à ionisation et les MOSFET ont été caractérisés puis mis à l'étude lors de traitements afin de mesurer la dose à la sortie du patient et de calculer la dose au point de prescription à la mi-plan du patient.
79

Évaluation des impacts anatomique et dosimétrique des mouvements induits par la respiration

St-Pierre, Christine 18 April 2018 (has links)
Le mouvement induit par la respiration dans la région thoraco-abdominale a été évalué à l'aide de séries d'images de tomodensitométrie en quatre dimensions (4DCT) pour un échantillon de 40 patients présentant principalement des tumeurs pulmonaires et gastro-intestinales. L'observation du déplacement des structures par rapport à leur position d'équilibre respective a révélé un déplacement en phase en supérieur-inférieur. L'amplitude est plus importante pour le diaphragme et les reins. Il n'y a pas de différences significatives entre les tumeurs pulmonaires et les autres sites étudiés. La méthodologie de planification dosimétrique actuelle (3D-CRT ou IMRT) s'est révélée adéquate en moyenne pour une population de 10 cas de tumeurs pulmonaires ayant une grande amplitude de déplacement. L'utilisation de la phase de mi-ventilation ne modifie pas significativement la couverture de dose, mais diminue les variable dosimétriques du poumon. La moyenne des phases du 4DCT n'apporte pas d'avantages par rapport à la méthodologie actuelle. / Respiration-induced motion in the thoracoabdominal region was studied with fourdimensional computed tomography (4DCT) for 40 patients mainly with lung and gastrointestinal tumours. Relative distance to mean amplitude position of internal structures showed an inphase motion in superior-inferior direction. Diaphragm and kidneys displayed in average the greatest amplitude. There were no significant amplitude differences between lung and other locations motion. The actual treatment planning method (3D-CRT or IMRT) turned out to be, in average, adequate for ten lung cases with large motion. The use of mid-ventilation phase for treatment planning does not change significantly dose coverage but lower lung dosimetric parameters. The use of 4DCT average showed not benefits over the actual procedure.
80

Caractérisation d’un système d’acquisition CCD sans lentilles pour la mesure de dose employant un dosimètre à scintillateur plastique

Gagnon, Louis-Philippe 19 April 2018 (has links)
Actuellement, les mesures de dose en radiothérapie sont effectuées en employant différents types de détecteurs tels que les chambres à ionisation, les diodes et les films radiosensibles. Bien que ces différents détecteurs permettent d’obtenir une mesure de dose très précise, aucun d’entre eux n’a les propriétés nécessaires pour permettre la mesure de dose en temps réel sur un patient tout en ne perturbant pas le champ radiatif de traitement. Depuis une vingtaine d’années, les scintillateurs plastiques gagnent en popularité grâce à leurs propriétés relativement identiques à celles de l’eau, et du fait qu’ils génèrent un signal lumineux proportionnel à la dose déposée. Cette étude vise à construire un dispositif CCD sans lentilles pour la collecte de la lumière de scintillation, pour ensuite caractériser le signal obtenu et comparer le tout à un système optique plus conventionnel à base de lentilles. Pour ce faire, nous avons conçu un détecteur à fibre scintillante ayant servi pour l’acquisition des mesures des deux systèmes étudiés, soit le système à objectif photographique et le système équipé d’un « taper » à fibre optique. Nous avons évalué les signaux mesurés en termes de qualité par le ratio de signal sur bruit, en limite minimale de dose mesurable, en stabilité et en reproductibilité des mesures. Les résultats obtenus démontrent la supériorité du nouveau système sans lentille sur le système conventionnel en termes de gain de collecte de photon et en diminution des incertitudes de mesures. Ces résultats ouvrent la voie à des applications de mesure de très faibles doses et à la réduction des dimensions des détecteurs à des fins d’applications cliniques « in vivo », ou encore pour effectuer divers tests de contrôle de qualité des appareils.

Page generated in 0.06 seconds