Quantificação de imagens tomográficas para cálculo de dose em diagnose e terapia  em medicina nuclear / Quantification of tomography images for dose calculation for diagnosis and therapy in nuclear medicine

Massicano, Felipe 05 November 2010 (has links)
A área da medicina nuclear possui uma crescente vertente em terapia de doenças, particularmente no tratamento de tumores radiosenssíveis. Devido à alta dose utilizada na terapia desses tumores é de extrema importância a quantificação da distribuição da dose, para assim evitar os efeitos deletérios nos tecidos sadios. No Brasil o sistema de dosimetria interna utilizado é o MIRD (Medical Internal Radiation Dose) baseado em um modelo de referência que não possui dados suficientes do paciente para obter uma avaliação detalhada da dose em terapia. Novos sistemas de dosimetria interna utilizam imagens de tomografia computadorizada para obter tanto informações do corpo do paciente, como informações da distribuição da atividade interna do paciente, para assim, com base nessas informações, realizar o cálculo de dose mediante um código de Monte Carlo. Esse tipo de dosimetria é denominado dosimetria personalisada do paciente. No Centro de Engenharia Nuclear do Ipen, está em desenvolvimento uma metodologia em que as informações das imagens tomográficas são inseridas no código de Monte Carlo MCNP5 mediante um software denominado SCMS (Sistema Construtor de Manequins Segmentadores). Assim, a dosimetria pode ser realizada de forma personalizada para cada paciente, obtendo-se a deposição de energia nos órgãos de interesse. O presente trabalho teve por objetivo contribuir para a área de medicina nuclear com o desenvolvimento de parte do sistema mencionado de dosimetria personalizada do paciente para terapia radionuclídica. Para isso foram propostos três objetivos específicos: (1)Desenvolver um software para converter imagens de tomografia computadorizada (CT) em parâmetros do tecido (ρ,ωi); (2) Desenvolver um software para realizar a correção de atenuação em imagens tomográficas de medicina nuclear (SPECT ou PET) para fornecer o mapa de atividade relativa e (3) Preparar os dois softwares anteriores para fornecerem dados de entrada ao SCMS. O software desenvolvido para o primeiro objeto específico foi o Image Converter Computed Tomography (ICCT) que obteve uma boa precisão para determinar a densidade, e em relação à composição dos tecidos, os únicos elementos que obtiveram alta variação foram o carbono e oxigênio. Felizmente, essa variação para a faixa de energia utilizada em terapia radionuclídica não é prejudicial para a distribuição da dose. Uma das vantagens é a alta precisão em relação a cálcio e fósforo que possuem grande influência na distribuição da dose. Para o segundo objetivo foi desenvolvido o Attenuation Corretion PET SPECT (ACPS) que efetua a correção de atenuação em imagens de PET e SPECT mediante o método de Chang de 1a ordem e gera a distribuição da atividade relativa no interior do paciente. Por fim, os dados gerados pelos dois softwares foram formatados para o SCMS. / The nuclear medicine area has an increasing slope in the therapy of diseases, particularly in the treatment of radiosensitive tumors. Due to the high dose levels in radionuclide therapy, it is very important the accurate quantify of the dose distribution to avoid deleterious effects on healthy tissues. In Brazil, the internal dosimetry system used is the MIRD (Medical Internal Radiation Dose) based on a reference model that does not have adequate patient data to obtain a dose accurate assessment in therapy. However, in recent years, internal radionuclide dosimetry evaluates the spatial dose distribuition basead on information obtained from CT and SPECT or PET images together with the using of Monte Carlo codes. Those systems are called patient-specific dosimetry systems. In the Nuclear Engineering Center at IPEN, this methodology is in development. When the CT images are inserted into the Monte Carlo code MCNP5 through of use of a interface software called SCMS the dosimetry can be accomplished using patient-specific data, resulting in a more accurate energy deposition in organs of interest. This work aim to contribute with the development of part of that patient-specific dosimetry for therapy. To achieve this goal we have proposed three specific objectives: (1) Development of a software to convert images from Computed Tomography (CT) in the tissue parameters (ρ, ω(i)); (2) Development of a software to perform attenuation correction in nuclear medicine tomographic images (SPECT or PET) and to provide the map of relative activity and (3) Provide data to the SCMS code by these two softwares. The software developed for the first specific objective was the Image Converter Computed Tomography (ICCT), which obtained a good accuracy to determine the density and the tissue composition; the elements that had high variation were carbon and oxygen. Fortunately, this variation for the energy range used in radionuclide therapy is not detrimental to the dose distribution. A major advantage is the high accuracy obtained to calcium and phosphorus which have great influence on the dose distribution calculation. For the second objective it was developed the Attenuation Corretion SPECT PET (ACPS) software which performs the attenuation correction in PET and SPECT images through of 1a order Chang method and create the relative activity distribution within of patient. Finally, the data generated by the two softwares, was formatted to SCMS which in provides the complete information do the MCNP5 Monte Carlo code for radiation transport simulation for dose distribution estimation.
252

Confecção e caracterização de dosímetros luminescentes de cerâmicas de BaTiO3 nanoestruturadas. / Preparation and characterization of luminescent dosimeters nanostructured BaTiO3 ceramic.

Camargo, Shiva do Valle 23 August 2013 (has links)
Conforme pesquisas realizadas na literatura, o estudo do Titanato de Bário (BTO) na dosimetria é inédito, este material foi escolhido porque exibe propriedades luminescentes, demonstradas em experimentos de medidas de espectros de emissão. Para a confecção do BTO fez-se o uso da técnica química Sol-Gel, foi produzido amostras de BTO Puro, BTO dopado e co-dopado com diversas terras-raras. Todas as amostras produzidas sofreram calcinações com temperaturas definidas em 800, 1000 e 1200°C. As dopagens foram realizadas com os seguintes elementos terras-raras: Nd, Tb, Eu, Yb, Er, Pr, e as amostras co-dopadas foram com Tb/Eu e Yb/Er; no total foram confeccionadas trinta e uma amostras. No estudo de redução de massa foi constatada uma redução de metade das massas das amostras durante o processo de calcinação. Nas análises de Termoluminescência (TL) pelo menos uns dos tipos de calcinações apresentaram picos TL, com exceção das amostras co-dopadas com Tb/Eu. As amostras dopadas com Eu e Tb se destacaram nas análises das respostas termoluminescentes. A amostra com Tb e calcinada a 1200°C forneceu pico TL entre 90 a 200°C, e a dopada com Eu (1mol%) e calcinado a 1000°C apresentou picos TL em 110°C e 370°C. A mínima dose detectável para o pico de 110°C foi de 119 mGy e para o pico de 370°C foi de 143 mGy. As análises de MEV mostraram que as micrografias das amostras de BTO dopado tanto com Tb, quanto com Eu apresentaram superfícies porosas, diferentemente das Puras, que apresentaram superfície mais lisa. As análises de DRX indicaram uma fase tetragonal para as amostras Pura e dopadas com Eu (1 mol%), ambas calcinadas a 1000°C. / According to the literature, the study of Barium Titanate (BTO) for dosimetry is unpublished yet, this material was chosen because it exhibits luminescent properties, demonstrated in emission spectra experiments. To make the BTO samples the chemical sol-gel technique was used. Samples of BTO Pure, doped and co-doped with different rare earths were made. All produced samples were calcinated with temperatures at 800, 1000 and 1200°C. The doping was performed with the following rare earths: Nd, Tb, Eu, Yb, Er, Pr, and some samples were co-doped with Tb / Eu and Yb / Er; in total were made thirty-one samples. In the study of weight reduction, a reduction, by half of the mass of raw material, was observed during the calcination process. In the TL analysis, at least one of the types (temperature) of calcinations provides TL peaks formation, except for the samples co-doped with Tb / Eu. The BTO: Eu and Tb provided the best TL response. The BTO: Tb and calcined at 1200°C showed TL peak at 90 to 200°C and the one doped with Eu (1mol%) and calcined at 1000°C supplied peaks at 110°C and 370°C. The minimum detectable dose to the TL peak at 110°C was 119 mGy and for TL peak at 370°C was 143 mGy. SEM analyzes showed that the micrographs of BTO samples doped with both Tb and Eu supplied porous surfaces, unlike the pure sample, that showed smoother surface. XRD analyzes indicated a tetragonal phase to pure sample and the one doped with Eu (1 mol%), both calcined at 1000°C.
253

Montagem e caracterização de um fantoma para utilização em radioterapia utilizando imagens convencionais por ressonância magnética e contraste por transferência de magnetização / Phanton developing and caractherizing for radiotherapy using conventional magnetic resonance imaging and magnetization transfer contrast

Pastorello, Bruno Fraccini 04 August 2006 (has links)
A dosimetria 3D utilizando gel à base de monômeros é uma importante ferramenta utilizada em casos de Radioterapia, em que há necessidade de uma alta resolução da distribuição espacial de dose. Neste trabalho, desenvolvemos um gel à base de monômeros do acido metacrilico, denominado MAGIC®, com a finalidade de avaliar a distribuição espacial de dose em simulações de tratamento de radioterapia, utilizando duas técnicas de imagens por ressonância magnética, Magnetic Resonance Imaging (MRI): a relaxometria (RT) e a transferência de magnetização (Magnetization Transfer, MT). Para tal, o trabalho foi desenvolvido em três etapas. Na primeira, desenvolvemos fantomas para serem irradiados com radiação ? e x, sobre os quais imagens de ressonância foram obtidas e analisadas. Desenvolvemos também um software, escrito em Matlab®, para analisar as imagens e traçar curvas de isodose dos fantomas irradiados. Em seguida, aperfeiçoamos o preparo, a composição, e as maneiras de adquirir e processar as imagens do gel irradiado. Nessa etapa incorporamos o formaldeido ao gel MAGIC, aumentando sua sensibilidade em 15%. Por fim, simulamos cinco configurações de tratamento de radioterapia e avaliamos as isodoses adquiridas, comparando-as com aquelas obtidas pelo software de planejamento radioterápico virtual, TPS®. As avaliações feitas com a técnica de relaxometria corresponderam às nossas expectativas. Com ela foi possível caracterizar o gel MAGIC, com alguns testes dosimétricos, bem como avaliar as 5 simulações de tratamentos radioterápicos propostas. O gel se mostrou linear até 20 Gy, mas não apresentou níveis aceitáveis de reprodutibilidade, necessitando de uma curva de calibração em cada teste. O gel possui número atômico efetivo próximo ao da água não necessitando de fatores de correções. Na maioria dos casos simulados, as isodoses das simulações feitas com o gel MAGIC reproduziram as simulações virtuais. Infelizmente, não obtivemos, por enquanto, o mesmo sucesso com a avaliação por MT. As imagens de MT não se mostraram confiáveis e por esse motivo as simulações com o gel só foram feitas com a técnica de RT. / The 3D monomeric gel dosimetry is an important tool in radiation therapy cases which needs high spatial dose resolution. In this work we developed a methacrilic acid monomeric gel called MAGIC® to evaluate spatial dose distributions in simulations of radiation therapy treatments. We used two Magnetic Resonance Imaging (MRI) techniques, the relaxometry (RT) and the magnetization transfer (MT). The work was developed in three stages. First of all, the phantoms were created to be irradiated using and x radiations, the MRI were acquired and analyzed. We also developed a software, programmed in Matlab®, to analyze the images and to draw isodoses curves of irradiated phantoms. Following it, we improved the way the gel was prepared and its composition, as well the image acquisition and processing. In this part we added formaldehyde to the gel, improving its sensibility in 15%. Finally, we simulated 5 different radiation therapy treatments and compared the isodoses measured with the isodoses of the radiation therapy treatment planning software (TPS®). The results of the RT technique corresponded to our expectations. Using the RT we characterized the gel with dosimetric tests and evaluated five different radiation therapy treatments. The gel showed a linear relation with the dose until 20 Gy, but the results of the tests were not reproducibles, because of that we made a calibration curve for each test. The effective atomic number of the gel is close to the water, so it was not necessary any correction. In most of the simulated cases, the isodoses measured with the gel reproduced the virtual simulations. Unfortunately, until now, we didn\' t have the same success using the MT technique. The MT images were not reliable and because of that the simulations were only made with the RT technique.
254

Verificação de tratamentos radioterápicos diversos com dosimetria termoluminescente / Assessment of radiotherapic treatments with thermoluminescent dosimetry

Morlotti, Marcelo Scolaro 28 March 2007 (has links)
As técnicas radioterápicas evoluíram muito nas últimas décadas, destacando-se a utilização de feixes segmentados por colimadores de multifolhas, os quais permitem entregar maior quantidade de dose com maior precisão espacial. Os sistemas de planejamento em radioterapia (TPS), entretanto, são em grande parte fechados, com acesso restrito aos parâmetros de cálculo de dose. Desta forma, o presente trabalho teve como principal objetivo comparar valores de dose envolvidas em tratamentos radioterápicos, medidos com a técnica de dosimetria termoluminescente (TL), usando um objeto simulador antropomórfico (Alderson Rando Phantom - ARP) como paciente, com valores de referência extraídos dos TPS em simulações realistas de tratamento. O objeto simulador continha dosímetros TL de LiF (TLD100) posicionados na pelve, no tórax, na cabeça e no pescoço, a fim de que fossem monitoradas regiões com dose homogênea (como no volume alvo planejado - PTV), regiões com gradiente de dose e regiões afastadas do PTV. As irradiações foram feitas usando técnicas de radioterapia conformacional 3D e radioterapia por modulação da intensidade do feixe (IMRT). Quatro TPS foram utilizados: CadPlan, ECLIPSE, Helax-TMS e KonRad. Em algumas situações utilizaram-se algoritmos de cálculo implementados pelos fabricantes nos TPS; dois deles baseados em correção de heterogeneidades (Batho e pencil beam) e um deles baseado em convolução e superposição de feixes simulados (collapsed cone). Nos casos de irradiações com IMRT os algoritmos foram sempre usados. Paralelamente ao uso do ARP, utilizou-se um objeto simulador com água com objetivo de verificar o comportamento dos dosímetros TL expostos a feixes de fótons de alta energia, em comparação com câmaras de ionização cilíndricas do tipo Farmer (volume interno de 0,6 cm3). Além disso, esse objeto simulador possibilitou garantir a qualidade de suportes desenvolvidos para a câmara e para os dosímetros, nos casos de medidas em água. A irradiação da pelve do objeto simulador ARP, região com poucas heterogeneidades, revelou que o comportamento do material que o constitui é equivalente ao da água e, por isso, pode ser usado na simulação de tecido humano em feixes de radioterapia. Simulações de tratamentos revelaram compatibilidade entre valores medidos e planejados no interior do PTV, com discrepâncias menores que 2%; valores que estão dentro dos limites estabelecidos pelo ICRU62 (+7%/-5%, 2?). Nas regiões afastadas do PTV, todos os códigos de planejamento apresentaram discrepâncias relativamente grandes, evidenciando limitações no cálculo de componentes secondárias. Apesar dos algoritmos de cálculo aumentarem a concordância entre doses medidas e planejadas, não foi possível identificar diferenças entre os algoritmos pencil beam e collapsed cone. Em regiões onde havia alto gradiente de dose, as discrepâncias se tornam maiores devido à dificuldade em posicionar os dosímetros no mesmo ponto em que o cálculo é feito. Sistematicamente, observou-se que a técnica para radioterapia 3D apresenta valores de dose dentro dos limites preestabelecidos, enquanto IMRT mostra valores com maior exatidão. / The last decades noticed a massive improvement in radiotherapy techniques and the use of segmented beams produced by multileaf collimators. However, the dose radiation therapy planning systems (TPS) in use are characterized by the restriction of access to the calculation algorithms. The aim of this work was to compare dose values measured in an anthropomorphic phantom (Alderson Rando Phantom - ARP) to the reference dose values obtained from the TPS in real case simulations of radiotherapy treatments. Thermoluminescent dosimetry (TLD) technique was used to evaluate the doses. LiF dosimeters (TLD100) were positioned on the phantom pelvis, thorax, head and neck at homogeneous dose regions, as the Planned Target Volume (PTV), gradient dose regions, and areas far from PTV. The doses were delivered using two techniques, 3D conformal radiotherapy and Intensity Modulated Radiation Therapy (IMRT). Four TPS were used: CadPlan, ECLIPSE, Helax-TMS and KonRad. In several situations, calculation algorithms implemented in these planning systems were employed to take heterogeneities into account: two of them were correction-based algorithms (Batho and Pencil Beam) and one of them based in beam convolution-superposition (Collapsed Cone). Furthermore, a liquid water phantom was used to compare the TLD behavior to the Farmer thimble chamber (0,6 cc internal volume) results when exposed to high-energy photon beams. It was also possible to verify the quality of the PMMA supports that wer used in the calibration of the dosimeters on clinical beam, obtaining reliable results. Both the ARP pelvis and a water phantom showed similar behavior under irradiation, indicating that, in highly homogenous regions, the ARP material can be used to simulate human soft tissues under radiotherapy treatment. Inside the PTV, the dosimetry performed in the ARP, showed compatibility between measured and planned dose values, with discrepancies smaller than 2%, which are within the ICRU62 fixed limits (+7%/-5%, 2?). When the algorithms were used, a better agreement between the experimental and planned doses was achieved, but it was not possible to discriminate the Pencil Beam and Collapsed Cone algorithms. In regions with large dose gradients, the discrepancies between experimental and planned dose values are higher as the difficulties the position of the dosimeters are more critical. The measured doses, when the 3D radiotherapy technique was used, were within the ICRU62 pre-established limits whereas the IMRT technique provider more accurate values.
255

Dosimetria termoluminescente de altas doses de raios gama, raios beta, feixe de prótons e de nêutrons epitérmicos utilizando minerais naturais de silicatos e dosímetros de LiF: Mg, Cu, P (MCP) / High-dose thermoluminescent dosimetry of gamma rays, beta rays, proton beams and epithermal neutrons using natural silicate minerals and LiF: Mg, Cu, P (MCP) detectors

Carmo, Lucas Sátiro do 04 September 2015 (has links)
No mundo de hoje, onde o uso da radiação de diversas naturezas está generalizado, a quantificação da energia depositada por essas diferentes radiações se tornou uma atividade de grande importância, principalmente quando a faixa de energia é considerada elevada, estas altas energias de radiação estão presentes, geralmente, em aceleradores de partículas, reatores nucleares e em irradiadores industriais, por exemplo. Este trabalho tem como objetivo medir altas doses de radiação de raios gama, feixes de elétrons e feixes de prótons utilizando duas variedades de um silicato natural (água-marinha e goshenita) e medir altas doses de nêutrons epitérmicos de alta fluência utilizando dosímetros de Fluoreto de Lítio dopados com Mg, Cu e P (MCP). A técnica utilizada para medir a dose absorvida por esses materiais foi a termoluminescência. As irradiações com raios- γ provenientes de fontes de 60Co foram de 100 kGy a 2000 kGy para a água-marinha e de 600 kGy a 2000 kGy para a goshenita, os resultados de intensidade TL vs Dose mostram que a partir de certa dose - 250 kGy e 1234,8 kGy para água-marinha e goshenita, respectivamente - o sinal TL começa a decrescer. Foi observado neste trabalho que, estes materiais quando irradiados com tais doses e posteriormente irradiados com doses baixas de alguns Gys até cerca de 400-500 Gy, o sinal TL decresce regularmente, podendo ser utilizado na dosimetria das radiações nessa faixa de dose. Para a irradiação de feixe de prótons e de feixe de elétrons foram utilizados dosímetros em placa de goshenita e dosímetros de pastilhas de água-marinha, a carga do feixe de prótons vai de 20 a 216 μC e a dose do feixe de elétrons vai de 10 kGy a 70 kGy. As irradiações com nêutrons epitérmicos utilizando LiF: Mg, Cu, P foram realizadas no reator IEA-R1/IPEN com fluências de 1014 a 1017 n/cm² e a quantificação das doses absorvidas foram realizadas utilizando o método UHTR (Ultra High Temperature Ratio). / In the present days the usage of ionizing radiation from several different sources is spread all over the world. The measurement of the absorbed energy from these radiations became a very important task, mainly when the dose range is considered being in a very high level. These high energies of radiation are associated with particles accelerators, nuclear reactors and industrial irradiators, for example. This work is concerned for measuring high-doses of gamma radiation, electron beams and proton beams using two varieties of a natural silicate (aqua-marine and goshenite) and measuring effects of high-fluence neutrons using LiF: Mg, Cu, P (MCP) detectors. Thermoluminescence was employed to measure the absorbed dose for irradiations with gamma rays ranging from 100 kGy up to 2000 kGy for aquamarine and from 600 kGy and 2000 kGy for goshenite. The TL intensity reaches maximum at 250 kGy in aquamarine and at 1234 kGy for goshenite; this means that for doses larger than 250 kGy in aquamarine and 1234 kGy in goshenite the TL intensity drops. However, the descending part can be used in very high dose dosimetry. Furthermore, has been observed in this study that starting with aquamarine irradiated with 250 kGy and goshenite with 1234 kGy, the subsequent irradiation with doses from low to 400-500 Gy produces a regularly decreasing TL intensity, so that it can be used in radiation dosimetry from low to 400-500 Gy doses. For proton beams, goshenite were used. The beam charge ranges from 20 a 216 μC. For electron beams small pressed pellets of aquamarine were used. The dose ranges from 10 kGy to 70 kGy. The epithermal neutron irradiation was performed at IEA-R1 research reactor at IPEN and MCP-LiF detectors were used to measure the absorbed dose. A method called UHTR (Ultra High Temperature Ratio) was employed for calculating the amount of energy absorbed by the dosimeter. The fluence of epithermal neutrons ranges from 1014 a 1017 n/cm².
256

Músicos de pop-rock: queixas auditivas e não auditivas decorrentes da exposição à música eletronicamente amplificada / Pop-rock musicians: auditory and non-auditory effects due to electronically amplified music exposure

Salgado, Joana D Arc Aparecida 31 January 2012 (has links)
Made available in DSpace on 2016-04-27T18:11:54Z (GMT). No. of bitstreams: 1 Joana DArc Aparecida Salgado.pdf: 633670 bytes, checksum: 89b7c4535d7f94caddc5a7dde577a01c (MD5) Previous issue date: 2012-01-31 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Introduction: The musicians are part of a professional category under the risk of auditory issues and health complaints, due to electronically amplified music exposure. Objective: Measuring sound levels and identifying auditory and non-auditory complaints on pop-rock musicians groups. Method: 34 male pop-rock musicians, ages between 26 and 60 years old were evaluated. The subjects answered a questionnaire composed of health history, complaints related to hearing and information about music exposure. The noise dosimeter was applied on the musicians during a band concert on a nightclub in São Paulo. It was used a dosimeter type 1, properly calibrated, in which the microphone was positioned behind the musician s ear, 5 minutes before the beginning of the presentation. Results: The prevalence of auditory complaints, loud sound intolerance and the felling of occluded ears was 20,6%. From all, 50% of the sample reported the thought of being exposure to that sound can damage their hearing. The majority (27, 79,4%) of the musicians work in this area for further than 10 years. The highest sound level obtained on Lmax variation medium maximum levels, Lavg - average levels and Lmin - medium minimum levels in dB (A) were of 129,6; 119,1 and 94,5 (respectively). The values were further above the maximum level daily allowed, according to the occupational legislation. Conclusions: Dosimeter can be useful on levels investigation. Although, measures for musicians protection must be immediately taken, so that it can avoid deleterious effects on this population health / Introdução: Os músicos representam uma categoria profissional sob risco de problemas auditivos e queixas de saúde, em decorrência da exposição à música eletronicamente amplificada. Objetivo: Medir os níveis sonoros e identificar queixas auditivas e não auditivas em músicos de bandas de pop-rock. Método: Foram avaliados 34 músicos de pop-rock, do sexo masculino, com idades entre 26 e 60 anos. Os sujeitos responderam um questionário com dados sobre histórico de saúde, queixas relacionadas à audição e informações sobre exposição à música. Foi realizada a dosimetria de ruído no músico durante uma apresentação da banda em uma casa noturna de São Paulo. Para tanto foi utilizado um dosímetro do tipo 1, devidamente calibrado, cujo microfone foi posicionado próximo à orelha do músico, cinco minutos antes do início da apresentação. Resultados: A prevalência das queixas auditivas intolerância a som intenso e sente os ouvidos tampados foi de 20,6%. Do total, 50% da amostra relataram achar que o som ao qual está exposto afeta sua saúde. A maioria (27, 79,4%) dos músicos trabalha na profissão há mais de 10 anos. Os maiores níveis sonoros obtidos nas variáveis Lmax nível médio máximo, Lavg nível médio e Lmin nível médio mínimo em dB (A) foram de 129,6; 119,1 e 94,5 (respectivamente). E os menores foram de 105,9; 94,5 e 62,2 (respectivamente). Os valores estavam muito acima dos níveis máximos diários permitidos, segundo a Legislação Trabalhista. Conclusões: A dosimetria pode ser útil na investigação dos níveis. Entretanto, medidas de proteção aos músicos devem ser imediatamente adotadas com o objetivo de evitar os efeitos deletérios à saúde dessa população
257

Campos pequenos de radiação e materiais alternativos em dosimetria com espectroscopia de ressonância magnética eletrônica / Small radiation field and alternative materials in dosimetry with electron magnetic resonance spectroscopy

Amanda Burg Rech 26 June 2017 (has links)
Para acompanhar os avanços em radioterapia, os sistemas dosimétricos necessitam de aperfeiçoamento para garantir a acurácia do tratamento; e, paralelamente, a exposição radioativa vai além do uso clínico, sendo de interesse também a detecção em cenários radiológicos imprevistos. A espectroscopia de ressonância magnética eletrônica (RME) é capaz de detectar centros paramagnéticos criados em materiais expostos à radiação, relacionando resposta espectral com dose absorvida, executando assim a dosimetria de maneira não destrutiva, ao preservar a informação após a leitura. Após a padronização da alanina como detector de altas doses e a também aplicabilidade em estudos clínicos, dificuldades apresentadas propiciaram a investigação de outros materiais para dosimetria com RME; em contrapartida, classificar compostos presentes no cotidiano e com possibilidade de tecido equivalência é outro argumento para a expansão da análise de materiais alternativos. O desenvolvimento desta tese é entre dois tópicos distintos, porém interligados; primeiramente são apresentados minidosímetros para uso em campos pequenos, com abordagem clínica, e então a investigação de materiais alternativos, ambos para uso em dosimetria com RME. Em relação aos minidosímetros, o formato de pastilha é estudado, e são apresentados um novo conceito de detector, denominado EPResize®, e auditoria de ponta-a-ponta de um tratamento de radiocirurgia estereotáxica; sobre a investigação de materiais, foram estudados mais de 20 compostos, estes baseados em amônio, lítio, potássio e sódio. Os resultados mostraram que as dificuldades na determinação de dose com campos pequenos para um intervalo de dose clínico é uma questão que ainda necessita de muita atenção e adequação dos sistemas dosimétricos, de modo a extrair a maior sensibilidade possível, necessitando empregar parâmetros e métodos de análise além do rotineiramente utilizados; variados materiais se apresentaram adequados para a dosimetria com RME, tais como sulfato de amônio, formiato de sódio, ditionito de sódio, citrato de sódio e diferentes sulfitos, mesmo quando não satisfazendo aspectos clínicos, são alternativas para controle e determinação de doses em cenários não usuais. A capacidade de realizar a dosimetria com RME para campos pequenos e a padronização deste sistema possibilitam a verificação de tratamentos mais confiáveis em radioterapia não convencional; e a disponibilização de maior variedade de materiais para dosimetria com RME facilita a necessidade de mapeamento de dose em casos não previstos. / To keep up with advances in radiotherapy, dosimetric systems need improvement to meet the standards established for treatment accuracy; simultaneously, radioactive exposure goes beyond clinical use, and the detection in unforeseen scenarios is of interest too. Electron magnetic resonance spectroscopy (EMR) can detect paramagnetic centers created in materials exposed to radiation, relating spectral response with absorbed dose, thus performing non-destructively dosimetry, by keeping the information after the readout. After standardization of alanine as a high dose detector and the applicability in clinical studies, difficulties allowed the investigation of other EMR dosimetry materials; on the other hand, classifying compounds that are present daily and with the possibility of tissue equivalence is another stimulus for the expansion of alternative materials analysis. The development of this thesis is between two distinct but interconnected topics; first minidosimeters are presented for small field dosimetry, with a clinical approach, and the investigation of alternative materials, both topics applied in EMR dosimetry. Concerning the minidosimeters, some pellets aspects are studied, a new concept of detector, called EPResize®; and a stereotactic radiosurgery end-to-end audit are presented; about alternative materials research, more than 20 compounds were studied, based on ammonium, lithium, potassium and sodium. The results showed that the difficulties in determining the dose with small fields in a clinical dose range is an issue that still needs much attention and adequacy of the dosimetric systems, in order to extract the greatest possible sensitivity, with the need to employ parameters and methods of analysis besides the daily used; several materials were adequate for EMR dosimetry, such as ammonium sulfate, sodium formate, sodium dithionate, sodium citrate and different sulfites, which, even when not satisfying clinical aspects, are alternatives for control and determination of doses in other scenarios. The ability to perform clinical dosimetry with RME and the standardization of this system allow the improvement of treatments accuracy, and the availability of a greater variety of EMR dosimetry materials facilitates the need for dose mapping unforeseen cases.
258

Distribuição da dose absorvida no tratamento da micose fungóide através da dosimetria Fricke Xilenol Gel / Absorbed dose distribution in the treatment of Mycosis Fungoides using Fricke Xylenol Gel dosimetry

Silveira, Michely Cristina da 28 May 2010 (has links)
A radioterapia utiliza a radiação ionizante para a destruição de células tumorais. O controle da dose absorvida de um tipo específico de radiação aplicada a um volume alvo (tumor) é feito através da dosimetria, (uso de sensores de radiação), que neste trabalho foram utilizados os dosímetros químicos Fricke e filme. Dentre os diversos tipos de câncer, indicados para tratamento, utilizando a radiação ionizante, têm-se também a neoplasia Micose Fungóide (MF), linfoma que se alastra na superfície e em profundidade na pele para o qual elétrons com alta energia são utilizados para seu tratamento, devido aos seus alcances. Neste trabalho o Fricke Xilenol Gel (FXG) foi utilizado para o planejamento do tratamento da MF, para averiguar a distribuição da dose absorvida proveniente das interações dos elétrons com os tecidos. Para tal, foram construídas cubetas especiais em acrílico (tomos) conformacionadas aos contornos do crânio e do abdômen, que uma vez preenchidas com o FXG serviram para avaliar as doses absorvidas num objeto simulador antropomórfico, o Rando Phantom. O simulador, completado com cubetas e filmes radiocrômicos, este último também conformacionado aos dois contornos de interesse, foi submetido à técnica de Stanford para irradiação do corpo total com elétrons de 6 MeV. Imagens CCD e de densidade radiográfica foram feitas e posteriormente avaliadas, através de perfis horizontais e verticais passando por seus centros. Estes a seguir foram analisados por programas computacionais: um desenvolvido no Matlab para as imagens do FXG e o outro pelo programa já conhecido, ImageJ, para as imagens do filme. Das medidas, pode-se inferir que o dosímetro FXG se presta, similarmente ao filme, para as avaliações da dose absorvida devida aos elétrons na superfície do paciente e no seu interior, devida à contaminação por raios-X. / Radioterapy uses ionizing radiation to destroy tumor cells. The absorbed dose control in a target volume is done through dosimetry, using radiation sensors, being the Fricke and film used in this study. Among several types of cancer indicated for treatment using ionizing radiation, there is also the Mycosis Fungoides (MF), lymphom that spreads on surface and depth in the skin, for which high-energy electrons are used for its treatment. In this work the Fricke Xylenol Gel (FXG) was used for MF treatment control, to obtain the absorbed dose distribution from electrons interaction with the tissues. For this scope cuvettes were manufactured of acrylic (slices), with the same contours of the skull and abdomen anthropomorphic simulator tomos. Once filled with the FXG, these cuvettes were used to infer the absorbed dose by the anthropomorphic simulator Rando Phantom. This simulator, completed with the cuvettes and radiochromic films, this last one also with the same contours similar to skull and abdomen were submitted to the Stanford technique, for 6 MeV electrons total body irradiation. CCD and radiographic density images were acquired and evaluated by horizontal and vertical profiles through theirs centers. These profiles were analyzed through a computer programs: one developed in Matlab for FXG images and the other by an already known program, ImageJ, for film images. From the results one can infer that the FXG dosimeter presents similarity with that of film, in the evaluation of the absorbed dose distribution on surface and also inside of the patient.
259

Implementação de uma análise computadorizada da curva de emissão termoluminescente e aplicação em dosimetria clínica / Implementation of a computerized glow curve analysis and application in clinical dosimetry

Ferreira, Marcela Felix Chaves 28 February 2018 (has links)
Nas décadas de 1960 e 1970, as primeiras investigações de dosímetros termoluminescentes (TLD), especificamente, os picos dosimétricos, rapidamente revelaram um número surpreendente de fenômenos que poderiam estar diretamente relacionados à densidade de ionização. Um pouco mais tarde, nos anos 80 e no início dos anos 90, a radiação aparentemente desconectada induziu fenômenos que foram descobertos em outros sistemas baseados em fluoreto de lítio (LiF). A última década, no entanto, testemunhou o surgimento de vários modelos, encabeçado através de uma compreensão mais profunda dos mecanismos TL subjacentes, bem como na modelagem micro dosimétrica e especificamente desenvolvida para explicar fenômenos de densidade de ionização. Muitas aplicações em radioterapia fornecem níveis de dose de radiação superiores a 1 Gy, porém em radiodiagnóstico estão na faixa de alguns mGy, e níveis muito altos de precisão são necessárias para promover o tratamento ideal. Isto exige uma atenção muito cuidadosa aos protocolos de medição altamente detalhados, bem como à calibração demorada de todos os TLDs para corrigir a não-linearidade da resposta à dose. Essas propriedades podem variar de lote para lote e também podem ser uma função da exposição à radiação, do aquecimento e histórico de manuseio. Deste modo, mesmo com excelentes avanços nos estudos do TLD com relação aos tratamentos térmicos e às formas de análise da curva de emissão TL, é necessário continuar os estudos a fim de possibilitar uma melhor utilização desta técnica na clínica. Uma análise computadorizada da curva de emissão (CGCA do inglês, computadorized glow curve analisys) foi implementada utilizando dados provenientes do software WinREMS de dosímetros TL que absorvem e armazenam a energia da radiação ionizante, reemitida na forma de fóton na região do ultravioleta visível. A luz emitida é, então, detectada por uma fotomultiplicadora e correlacionada à dose absorvida recebida pelo material. Os picos de emissão foram ajustados por meio de um algoritmo no programa MATLAB adotando-se o modelo de cinética de primeira ordem. O material testado foi o LiF:Mg,Ti (fluoreto de lítio dopado com magnésio e titânio) da marca Harshaw e a qualidade do ajuste foi determinada por um parâmetro chamado figura de mérito (FOM - do inglês, figure of merit). O menor FOM obtido para o grupo de dosímetros foi de 1,04 % e o maior foi de 9,79 %. Também foi avaliada a dose mínima detectável, utilizando o parâmetro que apresentou melhor desempenho, segundo a homogeneidade do grupo de dosímetros. O valor médio de dose mínima apresentado foi 28 µGy. Os resultados de reprodutibilidade, índice de variabilidade do detector (DVI - do inglês, device variability index) foi 14,01 %, que pode ser explicado pelo alto número de dosímetros no lote. Então, com a diminuição do tempo de preparo do dosímetro e com a análise computadorizada da curva de emissão, a utilização clínica do TLD torna-se mais viável, visto que não houve interferência na sensibilidade do dosímetro. Apesar de a reprodutibilidade ter sido a cima do esperado, é indicado uma correção individual para cada dosímetro e o descarte daqueles que apresentarem valores mais discrepantes comparado ao lote. / In the decades of 1960 and 1970, the first investigations of termoluminescentes dosimeters (TLD), specifically, the dosimetric peaks quickly revealed a surprising number of phenomena that could be directly related to the density of ionization. A little later, in the years 80 and 90 at the beginning of the year, seemingly disconnected radiation induced phenomena were discovered on other systems based on lithium fluoride (LiF). The last decade, however, has witnessed the emergence of several models, spearheaded through a deeper understanding of the underlying TL mechanisms as well as in modeling specifically developed for microdosimetric and explain phenomena of ionization density. Many applications in radiation oncology provide levels of radiation dose in excess of 1 Gy, however in diagnostic radiology are in the range of a few mGy, and very high levels of precision are necessary to promote the ideal treatment. This requires careful attention to the highly detailed measurement protocols, as well as the time-consuming calibration of all TLDs to correct the non-linearity of dose-response. These properties can vary from batch to batch, and can also be a function of exposure to radiation, heating and handling history. In this way, even with excellent advances in the studies of the TLD for the heat treatment and the ways of issuing TL curve analysis, it is necessary to continue studies in order to enable a better use of this technique in the clinic. A computerized analysis of the emission curve (CGCA computadorized glow curve analysis) was implemented using data from the WinREMS software of TL dosimeters that absorb and store energy from ionizing radiation, reissued in the form of photon in the visible ultraviolet. The light emitted is then detected by a photomultiplier and correlated to the absorbed dose received by the material. The emission peaks were adjusted by means of an algorithm in MATLAB program by adopting the model of first-order kinetics. The material tested was the LiF: Mg, Ti (lithium fluoride doped with magnesium and titanium) brand Harshaw and the quality of the fit was determined by a parameter called figure of merit (FOM- figure of merit). The smallest FOM obtained for the group of dosimeters was 1.04% and the highest was 9.79%. Also minimum detectable dose was evaluated, using the parameter that showed better performance, according to the homogeneity of the Group of dosimeters. The average value of minimum dose presented was 28 µGy. The results of reproducibility, index of variability of the detector (DVI-English, device variability index) was 14.01%, which can be explained by the high number of dosimeters in the batch. Then, with the decrease in the time of preparation of the dosimeter and the computerized analysis of the emission curve, the clinical use of the TLD becomes more viable, since there was no interference on sensitivity of the dosimeter. Although the reproducibility have been above expectations, indicated a single correction for each badge and the disposal of those who submit more discrepant values compared to the batch.
260

Avaliação de dose administrada no tratamento de neoplasia ginecológica por ressonância de spin eletrônico com L-alanina / Dose evaluation administered in the treatment of gynecological câncer by eléctron spin resonance with L-alanine

Rech, Amanda Burg 29 June 2012 (has links)
Neoplasias ginecológicas são os tumores de maior incidência no público feminino. Como alternativa para o tratamento destes tumores existe a radioterapia, em que a sua eficácia depende prioritariamente da correta administração da dose prescrita ao tumor, com acurácia de ±5%, conforme estabelecido pela American Association of Physicists in Medicine (AAPM). Para verificar a administração de doses existem diversas técnicas dosimétricas, entre elas a ressonância de spin eletrônico (RSE) com L-alanina, material tecido-equivalente, que relaciona dose com a quantidade de radicais livres formados pela radiação. Portanto, o objetivo deste estudo é a verificação da dose administrada na região tumoral de pacientes diagnosticadas com câncer ginecológico submetidas à teleterapia, utilizando L-alanina e a RSE. Para comparação entre as modalidades de radioterapia, foi realizada braquiterapia ginecológica com objeto simulador, verificando a dose no reto durante o tratamento, que deve ser inferior a 65% da dose prescrita ao tumor, conforme a International Commission on Radiation Units (ICRU). Para a análise de teleterapia foi construído um aparato, para a inserção vaginal do material radio-sensível, que foi utilizado durante 5 das 25 sessões de tratamento. As doses foram determinadas com o sistema de planejamento do tratamento mediante as imagens da tomografia computadorizada, em conjunto com softwares de planejamento, e a existência de marcadores radiopacos no aparato permitiu a confirmação das doses, conforme referência óssea através de imagens de portal feitas no momento anterior ao tratamento. Após a irradiação foi feita a leitura das amostras com o espectrômetro de RSE, em que a amplitude pico a pico da linha principal do sinal, normalizado pela massa, determinou a dose entregue nas regiões de interesse. Previamente ao estudo in vivo foi efetuada a teleterapia com objeto simulador, nas mesmas condições de tratamentos in vivo, apresentando desvio médio em relação ao planejamento de (0,2 ± 3,5)%, viabilizando o estudo com pacientes. Para a primeira paciente o desvio médio obtido foi de (0,5 ± 3,7)% e para a segunda de (-0,7 ± 2,8)%. Na simulação da braquiterapia o desvio médio observado foi de (-1,3 ± 9,2)%. Por causa do pequeno número amostral de pacientes, esta pesquisa é classificada como um estudo de viabilidade, em que a utilização de L-alanina com a RSE se mostrou eficiente para o objetivo proposto, fazendo com que os resultados da teleterapia estivessem de acordo com o estipulado pela AAPM e na braquiterapia a dose administrada no reto obedecesse ao relatório 38 da ICRU. / Gynecological malignancies are the most incident female tumors. As an alternative treatment for these tumors exist the radiotherapy, which their effectiveness mainly depends on the right administration of the prescribed dose to the tumor, with an accuracy of ±5%, as established by the American Association of Physicists in Medicine (AAPM). There are a lot of dosimetric techniques for dose verification, including electron spin resonance (ESR) with L-alanine, a tissue-equivalent material, which relates dose with the amount of free radicals formed by radiation. Therefore, the aim of this study is to verify the dose administered in the tumor of patients diagnosed with gynecological cancer subjected to external beam radiation therapy using L-alanine and ESR. For comparison between the radiotherapy modalities was performed gynecological brachytherapy in phantom, verifying the dose to the rectum during treatment, which must be less than 65% of the prescribed dose to the tumor, according to the International Commission on Radiation Units (ICRU). For teletherapy analysis was constructed an apparatus for vaginal insertion of the radio-sensitive material, which was used in 5 of the 25 treatment fractions. The doses were determined with the treatment planning system with the computed tomography images, together with the planning software, and the existence of radiopaque markers in the apparatus allowed the dose confirmation, according to the bone reference through portal images made before treatment. After the irradiation the samples was read with the ESR spectrometer, wherein the peak to peak amplitude of the signal main line, normalized by weight, determined the dose delivered into the regions of interest. Prior to the in vivo study was performed the teletherapy with phantom, under the same conditions of in vivo treatments, presenting mean deviation to the planning dose of (0.2 ± 3.5)%, enabling the study with patients. For the first patient, the mean deviation obtained was of (0.5 ± 3.7)% and for the second one of (-0.7 ± 2.8)%. In the brachytherapy simulation the mean deviation observed was of (-1.3 ± 9.2)%. Due to the small sample of patients, this research is classified as a feasibility study, which the use of L-alanine with the ESR was efficient for the objective proposed, making the teletherapy results consistent with the stipulated by the AAPM, and in the brachytherapy the dose to the rectum obey the ICRU report 38.