• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 334
  • 16
  • 9
  • 9
  • 9
  • 9
  • 6
  • 3
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 359
  • 248
  • 94
  • 80
  • 69
  • 56
  • 54
  • 54
  • 51
  • 51
  • 50
  • 44
  • 43
  • 40
  • 38
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
321

Efeito dos agentes clareadores sobre o esmalte dental, a resina composta e a interface dente/restauração / Effect of bleaching agents on the dental enamel, the composite resin and the tooth/restoration interface

Andréa Tami Abe 10 June 2014 (has links)
Este estudo in vitro teve como objetivo avaliar a dureza do esmalte dental, da resina composta, do adesivo e da camada híbrida em esmalte expostos a agentes clareadores à base de peróxido de hidrogênio a 35%, e analisar a interface dente/restauração com microscopia eletrônica de varredura (MEV). Foram utilizadas 40 coroas dentais de incisivos bovinos, que foram incluídas em resina epóxi. Uma cavidade de 2x2x2mm foi confeccionada no terço médio da face vestibular planificada de cada dente. As cavidades foram restauradas com o adesivo Adper Single Bond 2 e a resina nanoparticulada Filtek Z350 XT, e o polimento foi realizado após uma semana da confecção das restaurações. Os corpos de prova foram divididos em quatro grupos (n=10), correspondente a cada agente clareador à base de peróxido de hidrogênio a 35% utilizado (TB: Total Blanc Office; HPB: Whiteness HP Blue; HP: Whiteness HP; PO: Pola Office). A aplicação dos clareadores foi realizada 24 horas após o polimento, de acordo com as recomendações dos respectivos fabricantes. O valor do pH dos agentes clareadores foi medido no início e no final do procedimento clareador. A dureza dos substratos foi mensurada antes (inicial), imediatamente após o clareamento e após 7 dias de armazenamento em saliva artificial com o equipamento ultramicrodurômetro DUH-211S (Shimadzu). As cargas utilizadas foram de 100mN para o esmalte dental e para a resina composta, e de 10mN para o adesivo e para a camada híbrida em esmalte. Para a análise com MEV, foi confeccionado mais um corpo de prova para cada agente clareador, que foi replicado em resina epóxi a cada tempo de análise. Os testes estatísticos empregados foram a ANOVA de 2 fatores sendo 1 com vinculação (p<0,05) e o teste de Tukey. Quanto à dureza do esmalte e da camada híbrida, os corpos de prova expostos aos agentes TB, HPB e HP não apresentaram alteração da dureza nos três tempos de mensuração. O agente PO foi o clareador que apresentou o valor de pH mais baixo e o único que promoveu uma diminuição da dureza desses substratos imediatamente após sua aplicação, porém após 7 dias de armazenamento em saliva artificial a dureza retornou ao valor inicial. Nenhuma alteração foi observada quanto à dureza da resina composta e do adesivo expostos aos agentes clareadores utilizados. A análise em MEV revelou fendas entre o esmalte dental e o adesivo imediatamente após exposição à maioria dos clareadores. Pode-se concluir que o agente PO foi o único que diminuiu a dureza dos substratos dentais e o que promoveu a maior fenda na interface dente/restauração logo após sua aplicação. Nenhum clareador promoveu alteração da dureza da resina composta e do adesivo. / The aim of this in vitro study was to evaluate the hardness of the dental enamel, the composite resin, the dental adhesive and the enamel hybrid layer exposed to 35% hydrogen peroxide bleaching agents, and to analyze the tooth/restoration interface with scanning electron microscopy (SEM). Forty bovine incisor crowns were embedded in epoxy resin and then the labial surface of the teeth was flatted. One 2x2x2mm cavity was prepared on the middle third of each tooth labial surface. The cavities were restored with the adhesive Adper Single Bond 2 and the nanocomposite resin Filtek Z350 XT. After one week of storage, the restorations were polished. The specimens were divided into four groups (n=10), in correspondence to each 35% hydrogen peroxide bleaching agents used (TB: Total Blanc Office; HPB: Whiteness HP Blue; HP: Whiteness HP; PO: Pola Office). The bleaching procedure was performed 24 hours after polish, according to each manufacturer`s recommendation. The pH value of the bleaching agents was measured before and at the end of the bleaching procedure. Hardness test was performed before, immediately after bleaching and after storage in artificial saliva for 7 days, with the ultramicrohardness tester DUH-211S (Shimadzu). Indentations were performed using 100mN load for dental enamel and composite resin, and 10mN load for adhesive layer and enamel hybrid layer. For SEM analysis, one more specimen was made for each bleaching agent, which was replicated in epoxy resin at each measurement time. The statistical tests used were 2-way ANOVA and Tukey test (p<0,05). Regarding to dental enamel and enamel hybrid layer hardness, the specimens exposed to TB, HPB and HP agents did not present hardness alterations at any measurement time. The PO agent presented the lowest pH value and was the only that promoted hardness decrease on these dental surfaces immediately after application, however, after storage in artificial saliva for 7 days the hardness returned to initial value. No alteration was observed regarding to hardness of composite resin and adhesive exposed to bleaching agents. The SEM analysis revealed gaps between the dental enamel and the adhesive immediately after exposure to majority bleaching agents. In conclusion, the PO agent was the only that promoted hardness decrease on dental surfaces, and the major gap formation in tooth/restoration interface after application. No bleaching agents caused any alteration on composite resin and adhesive hardness.
322

Desenvolvimento de Ensaio Não Destrutivo baseado no Ruído Magnético de Barkhausen para caracterização de tensões elásticas e deformações plásticas em aços. / Development of Non-Destructive Test based on Magnetic Barkhausen noise for characterization of stress and elastic plastic deformation in steels.

Freddy Armando Franco Grijalba 30 April 2010 (has links)
Neste trabalho se estuda a aplicação de um método de Ensaio Não Destrutivo, baseado no Ruído Magnético de Barkhausen (RMB), na medição de falhas superficiais em aços. O RMB é gerado por abruptas mudanças na magnetização de materiais quando submetidos a campos magnéticos variáveis. Essas mudanças são afetadas pela microestrutura e a presença e distribuição de tensões elásticas (compressão e tração). Inicialmente apresenta-se um estudo de medições de tensões produzidas por flexão, e perfis de dureza, via RMB. Analisa-se a influência de parâmetros de medição e analise dos sinais, na qualidade do diagnostico. Analisou-se a sensibilidade dos sinais de RMB na medição de tensão a parâmetros tais como direção de laminação da chapa, intensidade e frequência de campo magnético de excitação. Nos estudos da aplicação do RMB em medições de dureza, se usaram amostras de ensaio Jominy, com variação contínua de dureza. Utilizou-se dois tipos de materiais e foram feitas medidas de dureza HRC, RMB e análise metalográfica. O comportamento de diferentes parâmetros dos sinais de RMB se correlacionou com as medições de Dureza e as micrografias obtidas. As amplitudes do RMB mostraram ser inversamente proporcionais aos níveis de dureza. Também se apresenta uma nova tecnologia para inspeção de superfícies, baseado no conceito do Barkhausen Contínuo. São apresentadas análises de parâmetros de medição e de configuração de sonda, na inspeção sob três situações: presença de defeitos volumétricos, deformação plástica, e tensões mecânicas aplicadas. Estudou-se a influência de parâmetros como, amplitude do campo aplicado, velocidade de varredura, posicionamento e características do sensor, no nível de detecção do dano. Métodos de processamento de sinais específicos foram desenvolvidos. Os resultados mostraram, que para cada um dos casos estudados, é possível detectar a posição e nível do dano produzido. Essa nova tecnologia aumenta o espectro de soluções de Ensaios Não Destrutivos para problemas não contemplados pelos métodos existentes. / This work studies the application of a non-destructive testing method, based on the Magnetic Barkhausen Noise (MBN). MBN is generated by abrupt changes in magnetization of ferromagnetic materials subjected to variable magnetic fields. These changes are affected by the presence and distribution of elastic stresses (compression and traction) in the material and by its microstructure. At first, the present study describes MBN measurements of stresses produced by bending and MBN measurements of hardness profiles, in steel samples. The influence of both, measurement parameters and signal analysis, in the quality of fault diagnosis is also analysed. In this context, regarding stress measurements, the MBN signal sensitivity to parameters like surface lamination direction, intensity and frequency of magnetic excitation field is studied. On the other hand, application of MBN to hardness measurements used Jominy essay samples presenting continuous hardness variation. In this case, samples of two different materials were employed and hardness measurements were obtained by HRC, MBN as well as by metallographic analysis techniques. Behaviour of different MBN signal parameters were correlated with obtained hardness measurements and micrography. MBN amplitudes were shown to be inversely proportional to hardness levels. Finally, the work describes a new surface inspection technology, based on the concept of Continuous Barkhausen. In this context, the study analyses probe configuration and measurement parameters, concerning inspection of surface fault from three different origins: volumetric, plastic deformation, applied mechanical stress. The influence of parameters like applied field amplitude, probe velocity, sensor position and characteristics, in detecting damage level was also evaluated. In particular, specific signal processing methods were developed. Results showed that, for each studied case, it is possible to detect damage position and level. This new technology increases the range of NDT essay solutions for problems not yet contemplated by existing methods.
323

Severe-to-mild wear transition during running-in of different steel-on-steel tribosystems in ball-on-disc dry sliding reciprocating tests. / Transição de desgaste severo-moderado de diferentes tribosistemas de ação contra ação durante ensaios reciprocantes a seco-disco-esfera.

Pablo Alejandro Correa Saldarriaga 16 April 2018 (has links)
The main motivation of this doctoral thesis is to extend the current knowledge about the tribological behavior of a precipitation-hardenable (PH) austenitic stainless steel (SAE XEV-F or DIN 1.4882), used for manufacturing exhaust valves for internal combustion engines in passenger cars. For this purpose, dry sliding laboratory tests were carried out using this steel and other steels, mainly austenitic and martensitic, used as model materials for the comparative characterization of wear and friction. Experimental tests were conducted using an SRV®4 tribometer in a ball-on-disc configuration with reciprocating movement, in which the discs were the samples and the balls the counter-bodies. Four kinds of steels were tested: a) AISI 310, b) SAE XEV-F, c) AISI H13, and d) Nitrided SAE XEV-F. The ball was made of AISI 52100 bearing steel. The tests were conducted at room temperature and fixed conditions of time (sliding distance) (up to 73.2 m), load (100 N), frequency (10 Hz) and stroke (2mm). Wear was evaluated by means of mass loss in the disc and the ball, and post examination of the worn surfaces. Post examination was conducted using scanning electron microscopy (SEM), coherence correlation interferometry (CCI), and X-Ray diffraction (XRD). Wear debris resulting from tribological interaction were also investigated using SEM and XRD. Additionally, the friction coefficient was measured. High speed filming and interrupted tests were also performed at specific sliding distances. This work reports a severe-to-mild wear transition occurring during the first stage of tribological interaction (running-in) and its relation to the load distribution variation at the interface throughout the tribological tests. The wear transition was observed in different steel-on-steel tribosystems in ball-on-disc contact configuration and occurred due to the combined effects of two factors: a) the contact pressure reduction, due to the increase of nominal contact area caused by wear; and b) subsurface strain hardening (when relevant). The pressure/distance variation was determined experimentally and modeled empirically. Subsurface strain hardening was observable (and measurable) mainly the austenitic steels. Significant differences in wear (and friction) were observed between homogeneous (monophasic) steels and the heterogeneous (multiphasic) SAE XEV-F valve steel. Wear in the homogeneous steels presented an inverse correlation with hardness. Wear on the AISI 310 presented non-linear wear rates for a significant portion of the test. Wear on the SAE XEV-F valve steel was pronounced (even in the mild regime) due to a combined effect of two factors: a) formation of hard debris, which induced an abrasive component to wear by relative sliding, and b) subsurface NbC fracture, which markedly affected the material removal due to plastic deformation in the surrounding matrix. Wear of the nitrided SAE XEV-F steel was lower than that of the non-nitrided samples by nearly two orders of magnitude. The benefits of nitriding in the SAE XEV-F were two-fold: a) an increased surface hardness, and b) the prevention of NbC fracture and detachment, which results in even higher wear resistance. / A principal motivação desta tese é ampliar o conhecimento atual sobre o comportamento tribológico de um aço inoxidável austenítico endurecível por precipitação (PH), o SAE XEV-F (ou DIN 1.4882), utilizado para a fabricação de válvulas de exaustão de motores de combustão interna para carros de passageiros. Para este propósito, foram realizados ensaios laboratoriais de deslizamento a seco usando este aço e outros, principalmente aços austeníticos e martensíticos, usados como materiais modelo para a caracterização comparativa do desgaste e do atrito. Os ensaios experimentais foram conduzidos usando um tribômetro SRV®4 em uma configuração esfera-disco com movimento alternado, em que os discos foram as amostras e as esferas são os contracorpos. Foram ensaiados quatro tipos de aços: a) AISI 310, b) SAE XEV-F, c) AISI H13, e d) SAE XEV-F nitretado. A esfera era feita de aço para rolamento AISI 52100. Os ensaios foram realizados a temperatura ambiente e usando condições fixas de tempo (distância total percorrida até 73.2 m), carga normal (100 N), frequência (10 Hz) e amplitude da oscilação (2 mm). O desgaste foi avaliado por meio de perda de massa, tanto do disco quanto da esfera, e exame das superfícies desgastadas utilizando microscopia eletrônica de varredura (MEV), interferometria de correlação de coerência (ICC) e difração de raios-X (DRX). Os debris de desgaste resultantes da interação tribológica também foram investigados usando MEV e DRX. Adicionalmente, a evolução do coeficiente de atrito foi analisada. Também foram realizadas filmagens de alta velocidade e ensaios interrompidos em tempos de deslizamento específicos. Este trabalho reporta uma transição de desgaste severo para moderado que ocorre durante as a primeira fase da interação tribológica (running-in) e sua relação com a variação da carga na interface durante os ensaios tribológicos. A transição de desgaste foi observada em diferentes tribo-sistemas de aço-contra-aço na configuração esfera-plano e ocorreu principalmente por efeitos combinados de dois fatores: a) a redução da pressão de contato, devida ao aumento da área nominal causada pelo desgaste; e b) o encruamento subsuperficial (quando relevante). A variação pressão/distância foi determinada experimentalmente e modelada empiricamente. Encruamento por deformação subsuperficial foi observável (e medível) principalmente nos aços austeníticos. Foram observadas diferenças significativas no desgaste (e atrito) entre os aços homogêneos (monofásicos) e o aço de válvula SAE XEV-F, heterogêneo (multifásico). O desgaste nos aços homogêneos apresentou uma correlação inversa com a dureza. O desgaste no aço válvula SAE XEV-F foi pronunciado (mesmo no regime de desgaste moderado) devido a um efeito combinado de dois fatores: a) a formação de debris duros, o que induziu uma componente abrasiva ao desgaste por deslizamento relativo, e b) a fratura subsuperficial do NbC, o que afetou significativamente a remoção de material devida à deformação plástica da matriz. O desgaste do aço nitretado SAE XEV-F foi menor que o das amostras não tratadas em quase duas ordens de grandeza. Os benefícios da nitretação no aço válvula SAE XEV-F foram dois: a) o aumento da dureza da superfície, e b) a prevenção da fratura e desprendimento de NbC, o que resulta em uma resistência de desgaste ainda maior.
324

Avaliação microbiológica, física e mecânica de materiais resilientes modificados pela adição de antimicrobianos para tratamento de estomatite protética / Microbiological, physical and mechanical evaluation of resilient materials modified by the addition of antimicrobial agents for denture stomatitis\' treatment

Mírian Galvão Bueno 31 October 2011 (has links)
No presente estudo, a proposta foi avaliar a ação antimicrobiana sobre o biofilme de Candida albicans (SC 5314) e determinar a mínima concentração inibitória (MCI) de cinco fármacos utilizados no tratamento de estomatite protética (nistatina, miconazol, cetoconazol, itraconazol e diacetato de clorexidina), quando incorporados em reembasadores resilientes temporários à base de resina acrílica (Trusoft e Softone) bem como o efeito dessa modificação sobre as propriedades de dureza Shore A e rugosidade superficial dos materiais. Para determinação das MCIs, o biofilme fúngico foi formado sobre corpos de prova circulares (10 mm x 1 mm) dos materiais (n = 6) modificados (experimentais) ou não (controle) pela adição dos fármacos. Diferentes concentrações dos antimicrobianos foram testadas e a viabilidade celular determinada espectrofotometricamente pelo ensaio de redução de sais de tetrazólio- XTT, nos períodos de 24 h, 48 h, 7 e 14 dias. As medidas espectrofotométricas foram convertidas em porcentagens de redução fúngica e as MCIs determinadas como aquelas suficientes para inibir 90% ou mais do crescimento de C. albicans. Para os ensaios de dureza e rugosidade, corpos de prova retangulares (36 mm x 7 mm x 6 mm) dos materiais resilientes (n= 8) foram confeccionados sem (controle) ou com incorporação dos fármacos nas MCIs previamente definidas. Após armazenamento em água destilada a 37°C por 24 h, 7 e 14 dias, foram realizados os testes de dureza em durômetro Shore A (Woltest, GSD-709A) e de rugosidade superficial em rugosímetro (Surftest SJ-301). Os resultados foram analisados estatisticamente por ANOVA 3 fatores, seguida pelo teste de Tukey (=0,05). De acordo com os resultados, as MCIs determinadas para fármacos incorporados aos materiais resilientes foram: 0,032, 0,256, 0,128, 0,256 e 0,064 g/mL para nistatina, miconazol, cetoconazol, itraconazol e clorexidina, respectivamente. A adição dos antimicrobianos em ambos os materiais não alterou os valores de dureza, ou resultou na sua diminuição em relação ao controle, exceto para a incorporação de miconazol ao Softone, que demonstrou maiores médias após 14 dias (P=0,0035). A incorporação de nistatina aos dois materiais, de clorexidina ao Trusoft e de cetoconazol ao Softone não alterou os valores de rugosidade em relação ao controle após 7 e 14 dias (P>0,05). Nesses períodos, o itraconazol aumentou a rugosidade dos materiais (P<0,0001). Em relação às 24 h iniciais, o período de 14 dias mostrou que a rugosidade com a adição de nistatina, miconazol e cetoconazol foi reduzida para o Trusoft (P<0,05) e não apresentou alteração para o Softone (P>0,05). Foi possível concluir que a incorporação dos antimicrobianos testados inibiu o crescimento de C. albicans nos materiais ao longo de 14 dias de avaliação. A adição de todos os fármacos testados, exceto o miconazol no Softone, não causou alterações deletérias à dureza dos materiais resilientes no período avaliado. No período final, a adição de nistatina, miconazol e cetoconazol em ambos os reembasadores e de clorexidina no Trusoft não resultou em efeitos adversos na rugosidade. / The purpose of this study was to evaluate the antimicrobial action on Candida albicans biofilm (SC5314) and determine the minimum inhibitory concentration (MIC) of five drugs for denture stomatitis\' treatment (nystatin, miconazole, ketoconazole, itraconazole, and chlorhexidine diacetate) incorporated into temporary denture relines (Trusoft e Softone) as well the effect of this addition on the Shore A hardness and surface roughness of the materials. For MIC determination, the fungal biofilm was formed on disc specimens (10mm x 1 mm) of the materials (n= 6) modified (experimental) or not (control) by the addition of drugs. Different dosages of the antimicrobials were tested and cellular viability was determined by spectrophotometric tetrazolium salt XTT reduction assay at 24 h, 48 h, 7 and 14 days of incubation. The spectrophotometric measurements were converted to percentage reduction in candidal growth and the MICs were determined as the concentrations necessary to inhibit 90% or more of fungal viability. For hardness and surface tests, rectangular specimens (36 mm X 7 mm X 6 mm) of the resilient materials (n= 8) were made without (control) or with incorporation of the MIC drugs. After storage in distilled water at 37°C for 24h, 7 and 14 days, the hardness tests were performed using a Shore A hardness tester (Woltest, GSD-709A) and the roughness assay was conducted in a surface roughness tester (Surftest SJ-301). Data were statistically analyzed by 3-way ANOVA followed by Tukeys test (=.05). According to the results, MICs of the drugs incorporated into the material were: 0.032, 0.256, 0.128, 0.256 e 0.064 g/mL for nystatin, miconazole, ketoconazole, itraconazole and chlorhexidine, respectively. The addition of the tested antimicrobial agents in both materials demonstrated no evident hardness change or resulted in its decrease compared to the control, except for miconazole incorporation into Softone, which increased the hardness values after 14 days (P = .0035). The addition of nystatin into the two materials, chlorhexidine into Trusoft and ketoconazole into Softone resulted in no significant changes of roughness values compared to the control after 7 and 14 days (P>.05). In these periods, itraconazole promoted increase of the roughness for both materials (P<.0001). Compare to the 24- h period, the roughness at 14- day time with the addition of nystatin, miconazole and ketoconazole was reduced for Trusoft (P<.05) and remained unaffected for Softone (P> .05). It can be concluded that the incorporation of antimicrobial agents inhibited the C. albicans growth on the materials up to 14 days. The addition of all tested drugs, except for the miconazole into Softone, resulted in no deleterious effects on hardness of the resilient materials over the evaluation time. At the end period, the incorporation of nystatin, miconazole and ketoconazole into both denture relines and chlorhexidine into Trusoft resulted in no detrimental changes on the roughness.
325

Propriedades mecânicas do titânio comercialmente puro e da liga Ti-6Al-4V fundidos em diferentes ambientes / Mechanical properties of commercially pure titanium and Ti-6Al-4V alloys casting in different environments

José Roberto de Oliveira Bauer 05 October 2007 (has links)
Problema: O emprego do titânio e ligas de titânio para aplicações médicas e odontológicas tem aumentado nas últimas décadas, porém, o alto custo do material desestimula o seu uso rotineiro. Objetivos: Avaliar o efeito da pureza do argônio nas propriedades mecânicas, microestrutura e modo de fratura do titânio comercialmente puro (Grau I) e da liga Ti-6Al-4V. Material e Métodos: As fundições para cada liga foram realizadas em uma máquina de indução eletromagnética com um argônio de alta pureza (99,999%) e um argônio conhecido como industrial (99,98%). Os testes de resistência à tração, limite de proporcionalidade e alongamento foram realizados em máquina de ensaio universal sob velocidade de 1 mm/min. Os espécimes fraturados foram embutidos em resina fenólica (baquelite) e polidas para a realização da microdureza Vickers (100g/15s), a a 25, 50, 100, 200 e 500?m da borda do corpo-de-prova. A microestrutura das ligas também foi analisada em alguns espécimes, com o objetivo de avaliar a superfície fraturada dos espécimes alguns foram submetidos à microscopia eletrônica de varredura. Análise estatística: Os dados provenientes de cada teste mecânico foram submetidos a uma análise de variância (tipo de titânio vs. pureza do argônio) e teste de Tukey (? = 0,05). Os dados de microdureza Vickers foram submetidos a uma análise de variância de medidas repetidas (fatores principais: liga e argônio) e medida repetida: distância e teste de Tukey para o contraste entre médias (? = 0,05). Resultados: O grau de pureza do gás não influenciou os valores do limite de proporcionalidade, da resistência à tração e alongamento, assim como a microdureza Vickers, microestrutura e padrão de fratura. A liga Ti-6Al-4V apresentou alto valores de resistência à tração, limite de proporcionalidade e microdureza Vickers, e baixo alongamento. A microdureza dos materiais foi alta nas proximidades da borda, mas a pureza do argônio não teve influência alguma. Conclusões: O argônio industrial pode ser utilizado para realizar as fundições do Ti CP e Ti-6Al-4V sem prejuízos nas suas propriedades. / Background: Although CP titanium and titanium alloys have been used for medical and dental applications, their high cost has not stimulated their current use. Objective: The purpose of this study was to evaluate the effect of argon purity on the mechanical properties, microstructure and fractography of CP Ti (Grade I) and Ti-6Al- 4V cast alloys. Material and Methods: The castings for each alloy were made in a centrifugal casting machine using either a high-purity (99.999%) and or an industrial argon gas (99.98%). The ultimate tensile strength (UTS), proportional limit (PL) and elongation (EL) were evaluated in a universal testing machine at a crosshead speed of 1 mm/min. The fractured specimens were embedded in phenolic resin and polished down for Vicker\'s microhardness (VHN) measurement (100g, 15s) from 25 ?m below the cast surface, then at 50?m, 100?m, 200?m and 500?m. The microstructures of the alloys were also revealed. Scanning electron microscopy fractography was undertaken for the fractured surfaces after tensile testing. The data from the mechanical tests and hardness were subjected to a two-way ANOVA and Tukey\'s test (? = 0.05). Results: The mean values of UTS, PL, EL and VHN were not affected by the argon gas purity. Higher UTS, PL and VHN and lower EL was observed for Ti-6Al-4V. The microhardness values of both alloys were higher at the surface layers and it was not influenced by the argon gas purity. Conclusions: It was concluded that the industrial argon gas can be safely used to cast CP Ti and Ti-6Al- 4V, since it does not alter the mechanical properties of the studied alloys.
326

Estudo de propriedades de resinas compostas bulk fill / Study of properties of bulk-fill resin composites

Ezequias Costa Rodrigues Júnior 20 January 2016 (has links)
Diante da evolução da composição das resinas compostas e do lançamento de compósitos do tipo bulk fill, faz-se necessário o estudo do desempenho dessa nova classe de materiais. Para isso, o presente estudo teve como objetivo avaliar propriedades como grau de conversão (GC) , dureza Knoop (KHN), resistência à flexão (RF) e tenacidade à fratura (KIC) de sete compósitos bulk fill (EverX Posterior, EXP; Filtek Bulk Fill Flow, FBFF; Fill-Up!, FU; SonicFill, SF; Surefil SDR, SDR; Tetric EvoCeram Bulk Fill, TECBF; Venus Bulk Fill, VBF) e um compósito nanohíbrido convencional (Charisma Diamond, CD). De forma complementar, foi realizado tratamento térmico a 170 °C por 10 minutos para melhor compreensão do comportamento desses materiais quanto ao potencial de conversão e à indução de tensões na interface carga/matriz. A avaliação do GC (n=3) foi realizada através de espectroscopia FTIR, a leitura da dureza Knoop foi realizada nas superfícies do topo e da base (n=3), e os ensaios de RF de três pontos (n=10) e KIC (n=10) em máquina de ensaios universais. Os resultados obtidos foram submetidos à analise de variância (complementados pelo teste de Tukey) ou teste Kruskal-Wallis, com nível de significância de 5%. A análise do GC (%) revelou diferença entre os materiais testados, sendo que todas as resinas bulk fill apresentaram valores maiores que a resina convencional: SF (75,7) > VBF (66,7) = EXP (66,4) = SDR (62,8), sendo esta também semelhante a FU (60,0); FU, TECBF (56,6), FBFF (56,6) e CD (54,5) apresentaram conversão semelhante. Os valores de KHN variaram de acordo com o material e com a superfície: apenas SF apresentou KHN semelhante (na superfície do topo) a CD, entretanto não foi possível realizar a leitura da superfície da base deste último material; SF, TECBF e FBFF apresentaram valores de KHN diferentes nas superfícies topo e base; EXP, FU, SDR e VBF mantiveram os valores de dureza do topo semelhantes à superfície da base. Para a RF (MPa), os resultados variaram de acordo com o material: EXP (122,54) = SF (101,09) = CD (99,15), sendo estes dois últimos semelhantes a FU (83,86) e TECBF (82,71), os quais não diferiram da resina SDR (65,18); esta última também mostrou comportamento semelhante a FBFF (60,85) e VBF (59,90). Quanto ao KIC (MPa.mm0,5), EXP (3,35) apresentou o maior valor, semelhante a SF (2,42), que por sua vez também foi igual ao compósito convencional CD (2,01); CD apresentou KIC semelhante a SDR (1,74); SDR = VBF (1,59) = TECBF (1,57); TECBF, FU (1,54) e FBFF (1,37) apresentaram valores semelhantes. Na dependência do material, o tratamento térmico aumentou os valores dos parâmetros estudados, apontando limitações da reação de polimerização dos compósitos estudados. Com base nos resultados obtidos, podese concluir que: resinas bulk fill apresentam elevado GC, superior à resina convencional estudada; a nova classe de materiais restauradores é capaz de polimerizar em profundidade e alguns materiais apresentam KHN semelhantes no topo e na base de espécimes de 4 mm de profundidade; RF e KIC variaram de acordo com o material, e o compósito EXP apresentou os maiores valores para ambos os testes. / Facing the evolution of the resin composites and the release of the bulk-fill composite type, it is necessary to study the performance of this new class of materials. For this, the present study aimed to evaluate properties such as degree of conversion (DC), Knoop hardness (KHN), flexural strength (FS) and fracture toughness (KIC) of seven bulk-fill composites (EverX Posterior, EXP; Filtek Bulk Fill Flowable, FBFF; Fill-Up!, FU; SonicFill, SF; Surefil SDR, SDR; Tetric EvoCeram Bulk Fill, TECBF; Venus Bulk Fill, VBF) and a conventional nanohybrid composite (Charisma Diamond, CD). Complementarily, heat treatment was performed at 170 °C for 10 minutes for better understanding the behavior of these materials. Evaluation of DC (n=3) was performed by FTIR spectroscopy, the evaluation of Knoop hardness was made on the top and bottom surfaces (n=3), and three point bending test (n=10) and KIC (n=10) were evaluated on a universal testing machine. The results were submitted to analysis of variance (complemented by Tukey test) or Kruskal-Wallis test with 5% significance level. Analysis of DC (%) revealed differences between tested materials, and all bulk-fill resins had higher values than the conventional resin: SF (75.7) > VBF (66.7) = EXP (66.4) = SDR (62.8), which was also similar to FU (60.0); FU, TECBF (56.6), FBFF (56.6) and CD (54.4) showed similar conversion. KHN values showed variations according to the material and the surface: only SF showed a similar KHN (on the top surface) to CD, however it was not possible to read the bottom surface of this latter material; SF, TECBF and FBFF presented different KHN values on the top and bottom surfaces; EXP, FU, SDR and VBF maintained top and bottom similar hardness values. For FS (MPa), the results varied according to the material: EXP (122.54) = SF (101.09) = CD (99.15), the latter two being similar to FU (83.86) and TECBF (82.71), which did not differ from SDR resin (65.18); the latter showed similar behavior to FBFF (60.85) and VBF (59.90). As for KIC (MPa.mm0.5), EXP (3.35) had the highest value, similar to SF (2.42), which in turn was also equal to the conventional composite CD (2.01); CD presented KIC similar to SDR (1.74); SDR = VBF (1.59) = TECBF (1.57); TECBF, FU (1.54) and FBFF (1.37) were similar. Depending on the material, heat treatment increased the values of the parameters, pointing limitations of polymerization reaction of the studied composites. Based on these results, it can be concluded that: bulk fill resins have high DC, higher than the conventional resin studied; the new class of restorative materials is capable of polymerizing in depth and some materials exhibited similar KHN at the top and bottom surfaces of 4 mm depth specimens; FS and KIC varied according to the material, and the EXP composite showed the highest values for both tests.
327

Influencia da irrigação endodontica sobre a microdureza, morfologia e rugosidade de dentes deciduos e permanentes / Endodontic irrigation effect on microhardness, morphology and roughness in primary and permanent teeth

Pascon, Fernanda Miori, 1977- 12 August 2018 (has links)
Orientador: Regina Maria Puppin-Rontani / Tese (doutorado) - Universidade Estadual de Campina, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-12T09:08:02Z (GMT). No. of bitstreams: 1 Pascon_FernandaMiori_D.pdf: 20418378 bytes, checksum: 123cef34dc5e16d51cd9c6553ae586c5 (MD5) Previous issue date: 2008 / Resumo: A utilização de substâncias químicas auxiliares, durante o tratamento endodôntico, pode alterar a composição química e as propriedades físicas da estrutura dentinária corono-radicular. Além disso, pode interferir no processo de união do material restaurador às estruturas dentinárias da câmara pulpar. Dessa maneira, pesquisas devem ser realizadas possibilitando a indicação de uma substância, que apresente o mínimo efeito nas propriedades mecânicas dentinárias, enquanto exerce o efeito de debridamento desejado. No intuito de facilitar a apresentação desta Tese, a mesma foi dividida em três capítulos, como descrito nas proposições seguintes. Capítulo 1: revisar sistematicamente a literatura a respeito dos efeitos da solução de hipoclorito de sódio nas propriedades mecânicas da dentina do canal radicular quando a mesma é utilizada durante o tratamento endodôntico. Capítulo 2: verificar os efeitos de diferentes substâncias químicas auxiliares (soro fisiológico, hipoclorito de sódio, clorexidina gel, peróxido de uréia - Endo-PTC® e EDTA) na microdureza (realizada por meio do teste de microdureza Vickers) e morfologia (realizada por meio de análise em Microscopia Eletrônica de Varredura) da dentina da câmara pulpar de dentes anteriores decíduos e permanentes. Capítulo 3: avaliar o efeito de substâncias químicas auxiliares (soro fisiológico, hipoclorito de sódio, clorexidina gel, peróxido de uréia - Endo-PTC® e EDTA) na rugosidade superficial da dentina da câmara pulpar de dentes decíduos e permanentes. Baseando-se na revisão de literatura pôde-se concluir que há forte evidência de que o hipoclorito de sódio altera as propriedades mecânicas da dentina radicular, quando o mesmo é utilizado como solução irrigadora durante o tratamento endodôntico. O uso de substâncias químicas auxiliares diminuiu os valores de microdureza dentinária Vickers tanto para dentes decíduos quanto para os permanentes. Observaram-se resultados não conclusivos com o uso do EDTA 17% na dentina da câmara pulpar dos dentes decíduos e permanentes uma vez que a microdureza superficial não pôde ser mensurada. A solução de hipoclorito de sódio 1% e 5,25% produziu os menores valores de microdureza Vickers para dentes decíduos e permanentes, comparados à clorexidina gel 2% e grupo controle (soro fisiológico). Alterações morfológicas foram observadas quando a dentina da câmara pulpar foi irrigada com solução de hipoclorito de sódio 1% ou 5,25% associados ao EDTA 17%, EDTA 17% utilizado isoladamente e clorexidina gel 2% associada ou não ao EDTA 17%. Em relação à rugosidade superficial pôde-se concluir que a irrigação da dentina da câmara pulpar aumentou a rugosidade superficial dos dentes permanentes e decíduos tratados com hipoclorito de sódio 1% e 5,25% associados ao EDTA 17%. / Abstract: Irrigation solutions, endodontic auxiliary chemical substance, and chelating agents used on root canal treatment might yield changes in the chemical composition and physical properties of dentin surface, and affect its interaction with materials used for coronal sealing. Thus, studies are required to select a suitable chemical agent, which has minimal effects on the mechanical properties of the tooth whilst achieving the desired debridement effect. In order to facilitate the accomplishment of this Thesis, it was divided into three chapters, as described on the following descriptions. Chapter 1: to present a systematic review on the effect of sodium hypochlorite on the mechanical properties of root canal dentin, considering its use as an irrigation solution. Chapter 2: to verify the effects of endodontic irrigants, auxiliaries chemicals substances and chelating agent on the microhardness (Vickers Hardness test) and morphology (Scanning Electron Microscopy) of the pulp chamber dentin in primary and permanent teeth. Chapter 3: to evaluate the effect of endodontic irrigants, auxiliaries chemicals substances and chelating agent on the roughness of the pulp chamber dentin of primary and permanent teeth. Based on literature review it could be concluded that there is strong evidence showing that sodium hypochlorite alters the mechanical properties of root canal dentin, when used as an endodontic irrigant. The use of irrigation solutions decreased the Vickers Hardness Number values for both permanent and primary teeth. Inconclusive results were observed when 17% EDTA was used, since it could not be measured. Sodium hypochlorite provides lower Vickers Hardness Number for primary and permanent teeth, compared with 2% chlorhexidine and control group (saline solution). Morphological alterations were observed when pulp chamber irrigation was performed by 1% or 5.25% sodium hypochlorite associated with 17% EDTA, 17% EDTA, and 2% chlorhexidine gel associated or no with 17% EDTA. Regarding surface roughness, it was concluded that pulp chamber irrigation with 1% and 5.25% sodium hypochlorite associated with 17% EDTA increases pulp chamber roughness of primary and permanent teeth. / Doutorado / Odontopediatria / Doutor em Odontologia
328

Modelos computacionais para análise da influência de parâmetros estatísticos de textura superficial no contato dentário humano

Oliveira, Evelyn Aparecida de 01 April 2016 (has links)
Submitted by isabela.moljf@hotmail.com (isabela.moljf@hotmail.com) on 2017-02-13T14:23:53Z No. of bitstreams: 1 evelynaparecidadeoliveira.pdf: 4026204 bytes, checksum: c1b720f3501ffcd12b38f9d4c877dfa9 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-02-13T16:49:50Z (GMT) No. of bitstreams: 1 evelynaparecidadeoliveira.pdf: 4026204 bytes, checksum: c1b720f3501ffcd12b38f9d4c877dfa9 (MD5) / Made available in DSpace on 2017-02-13T16:49:50Z (GMT). No. of bitstreams: 1 evelynaparecidadeoliveira.pdf: 4026204 bytes, checksum: c1b720f3501ffcd12b38f9d4c877dfa9 (MD5) Previous issue date: 2016-04-01 / O desgaste do dente, que se manifesta com uma grande variedade de graus ou níveis, é uma das anomalias dentárias comumente encontradas em diversas populações. A modelagem computacional do problema de contato oclusal pode ajudar na compreensão das interações entre os dentes, que gera concentrações de tensões. A abordagem utilizada para simular o contato entre as superfícies ásperas, dadas as funções de densidade de probabilidade das alturas das asperezas, consiste em discretizá-las em vários intervalos, de modo que cada um deles represente uma aspereza principal. As deformações das asperezas principais são analisadas e, utilizando técnicas de homogeneização, é possível estabelecer a relação entre as respostas que ocorrem em microescala e as respostas esperadas na macroescala. Neste trabalho, foi criada uma rotina para geração numérica de superfícies, um script acoplado ao programa de elementos finitos, Abaqus, para análise dos microcontatos, e, finalmente, um código para o procedimento de homogeneização e análise paramétrica das medidas de rugosidade. Na estimativa da dureza superficial, verificou-se que a curvatura média das asperezas exerce maior influência. Os parâmetros que mais influenciam nas forças e áreas de contato são o coeficiente de achatamento (kurtosis), cujo aumento leva ao decaimento dessas grandezas, seguido da rugosidade média quadrática, que, por sua vez, tem uma relação diretamente proporcional com a carga e consequentemente com a área de contato. / Tooth wear, which manifests with a great variety of degrees or levels, is one of the dental abnormalities commonly found in different populations. The computational modelling of the occlusal contact problem can help the comprehension of any interaction between teeth generating stress concentration. The approach used in this work to simulate contact between rough surfaces, given the probability density functions of asperities, consists in discretizing them in several intervals, so that each one represents a main asperity. The deformations of the main asperities are analyzed and, using homogenization techniques, it is possible to developed the relationship among the responses occurred in micro-scale and the predicted responses in macro-scale. In this work a routine has been established for numerical generation of surfaces, a script as well as has been coupled to the finite element program Abaqus, for analysis of the micro-contacts, and, finally, a code for homogenization and parametric analysis of the roughness measure. In the estimate of the surface hardness it was found that the mean curvature of the asperities exerts the largest influence. The parameters that influence the forces and contact areas are the flattening coefficient (kurtosis), which when increases leads to decay of these greatness, followed by the mean square roughness, which, in turn, has a direct proportional relationship with the strength and consequently with the contact area.
329

Transformações de fases e relação entre microestrutura e propriedades mecânicas de ligas Ti-Nb-Fe para aplicações biomédicas : concepção de implantes ortopédicos com rigidez gradual / Phase transformation and relationship between microstructure and mechanical properties of Ti-Nb-Fe for biomedical applications : design of orthopedic implants with graded stiffness

Lopes, Éder Sócrates Najar, 1982- 23 August 2018 (has links)
Orientador: Rubens Caram Junior / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecânica / Made available in DSpace on 2018-08-23T09:33:56Z (GMT). No. of bitstreams: 1 Lopes_EderSocratesNajar_D.pdf: 9279894 bytes, checksum: a2ed77cd79f48134e7daf5bc705afb0e (MD5) Previous issue date: 2013 / Resumo: Ligas de Ti do tipo ? metaestável exibem comportamento singular no tocante à possibilidade de manipulação de seu comportamento mecânico. Nessas ligas, a rigidez pode ser alterada por meio do controle das fases presentes, o que permite que esses materiais sejam incluídos no seleto grupo dos materiais com gradientes funcionais (functionally graded materials - FGM). Neste trabalho, objetivou-se projetar, produzir, processar, caracterizar e aplicar ligas Ti-Nb com adições do elemento ? estabilizador de baixo custo Fe. As ligas foram produzidas por fusão a arco voltaico e submetidas a diversas condições de tratamento térmico, incluindo solubilização acima da temperatura ?-transus, resfriamento rápido até a temperatura ambiente e tratamentos térmicos de envelhecimento entre 260 °C e 400 °C. A caracterização envolveu calorimetria diferencial de varredura, difração de raios-X e dureza Vickers em alta temperatura, análises metalográficas e de módulo de elasticidade por técnicas acústicas, ensaios de tração e mapeamento de rigidez por meio de nanoindentação. Os resultados obtidos mostram a retenção completa da fase ? para a liga Ti-30Nb-3Fe solubilizada e resfriada rapidamente e permitem também, compreender a decomposição da fase martensita ?" e a nucleação das fases ? e ?. A adição do elemento Fe tornou a cinética de transformação de fases bem mais lenta, propiciando, sob algumas condições, a supressão da fase ?, que é conhecida por aumentar a dureza em detrimento da ductilidade. Tais resultados foram utilizados no estabelecimento de condições ideais de processamento que permitem obter componentes ortopédicos com rigidez gradual. Finalmente, o conhecimento adquiro foi usado na fabricação de placas e parafusos de osteossíntese a partir da liga Ti-30Nb-3Fe com gradientes de funcionalidade / Abstract: Metastable ? Ti alloys exhibit singular behavior regarding the possibility of manipulating their mechanical behavior. In these alloys, the stiffness can be changed by controlling phases, which allows these materials to be included in the select group of functionally graded materials (FGM). This study aimed to design, produce, process, characterize and apply Ti-Nb alloys with addition of Fe, an inexpensive ? stabilizing element. These alloys were produced by arc melting and subjected to different heat treatment conditions, including solution above the ?- transus temperature, quenching to room temperature and aging heat treatments between 260 °C and 400 °C. Characterization involved differential scanning calorimetry, X-ray diffraction and Vickers hardness at high temperature, metallographic analyzes, elastic modulus by acoustic techniques, tensile test and stiffness mapping via nanoindentation. The results obtained show complete retention of the ? phase in the Ti-30Nb-3Fe alloy after solution in the ? field and rapid cooling to room temperature and also allow understanding martensite ?" decomposition and nucleation of the ? and ? phases. It was found that Fe additions make the phase transformation kinetics much slower, providing, for some conditions, suppression of the ? phase precipitation, which is known to increase the hardness at the expense of ductility. These results were used to establish optimal processing conditions, resulting in orthopedic component with graded stiffness. Finally, the knowledge acquired was used in the manufacturing of osteosynthesis plates and screws with functionality graded from the Ti-30Nb-3Fe / Doutorado / Materiais e Processos de Fabricação / Doutor em Engenharia Mecânica
330

Influência do peróxido de hidrogênio a 7,5% contendo cálcio, ACP, flúor e hidroxiapatita na microdureza, rugosidade superficial, alteração de cor e micromorfologia de esmalte humano / Influence of 7.5% hydrogen peroxide containing calcium, ACP, fluoride and hydroxyapatite on microhardness, surface roughness, color change and micromorphology of human enamel

Sasaki, Robson Tetsuo, 1980- 19 August 2018 (has links)
Orientador: Flávio Henrique Baggio Aguiar / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-19T14:51:35Z (GMT). No. of bitstreams: 1 Sasaki_RobsonTetsuo_M.pdf: 2754665 bytes, checksum: 23869c9999ee4e3552517da97aa3f84e (MD5) Previous issue date: 2012 / Resumo: O objetivo deste estudo in vitro foi determinar a microdureza, rugosidade superficial, micromorfologia e alterações de cor de esmalte dental humano submetido a tratamentos clareadores caseiros com peróxidos de hidrogênio a 7,5% (PH) adicionados de cálcio, fosfato de cálcio amorfo (ACP), flúor e/ou hidroxiapatita (HA). Três agentes de tratamento comerciais: (Pola Day 7,5% (PD), Day White ACP 7,5% (DW), White Class Calcium 7,5% (WC)), três agentes clareadores experimentais (PH 7,5% + NaF (PHF), PH 7,5% + HA (PHH) e PH 7,5% + NaF + HA (PHFH)) e os grupos controle positivo (gel de peróxido de hidrogênio a 7,5% - PC) e controle negativo (gel sem peróxido de hidrogênio a 7,5% - NC), foram avaliados (n=10). Os agentes de tratamento comerciais foram aplicados pelo prazo recomendado pelos fabricantes e os agentes experimentais por 1,5 hora por dia. Todas as amostras foram imersas em solução de saliva artificial pelo resto do dia, num total de 21 dias de tratamento. Após, ficaram armazenados em saliva artificial por 14 dias. Ensaios de microdureza, rugosidade superficial, micromorfologia do esmalte e análise de alteração de cor foram realizados nos tempos baseline, 7, 14, 21 dias de tratamento, 7 e 14 dias de pós-tratamento. Para análise estatística, as médias foram comparadas utilizando o teste de Tukey-Kramer com um nível de significância de 5%. Como resultados, no teste de rugosidade superficial (Ra) foi observado aumento em todos os grupos experimentais (PHF, PHH e PHFH) e nos grupos comerciais DW e WC ao longo do tempo. No teste de microdureza (KHN) observou-se um aumento significativo para o grupo PHH e redução significativa do grupo DW, enquanto os outros grupos não apresentaram alteração significativa ao longo do tempo de estudo. Para o teste de análise de alteração de cor, todos os agentes apresentaram efeito clareador, exceto o grupo NC, sendo que o grupo PHH foi o único que apresentou valores similares aos agentes clareadores comerciais em todos os tempos de estudo. Na análise morfológica observou-se alterações como a presença de porosidades na maioria dos grupos, exceto no grupo NC, além de deposição de cristais de hidroxiapatita nos grupos PHH e PHFH. Concluiu-se que o tratamento clareador contendo hidroxiapatita proporcionou alterações de cor similares aos agentes clareadores comerciais, foi capaz de aumentar a microdureza, e que quando este componente é formulado com ou sem flúor, pode levar a um aumento da rugosidade superficial, devido a deposição de cristais de hidroxiapatita na superfície de esmalte, como observado pela análise de microscopia eletrônica de varredura / Abstract: The aim of this in vitro study was to determine the microhardness, surface roughness, micromorphology and color change analysis of enamel submitted to with home-use bleaching treatment 7.5% hydrogen peroxide (HP) added with calcium, amorphous calcium phosphate (ACP), fluoride and/or hydroxyapatite (HA). Three commercial treatment agents: (Pola Day 7.5% (PD), Day White ACP 7.5% (DW), White Class 7.5% Calcium (WC)), three experimental bleaching agents (7.5% HP + NaF (PHF), HP + 7.5% HA (PHH) and PH + 7.5% NaF + HA (PHFH)), a negative control (Gel without 7.5% hydrogen peroxide - NC) and a positive control (Gel with 7.5% hydrogen peroxide - PC) groups were evaluated (n=10). The treatment agents were applied according to the manufacturer's recommendation and experimental agents were applied for 1,5 hour daily. Then all the specimens were immersed in artificial saliva for the rest of the day, in a total of 21 days of treatment. After the treatment phase, the specimens were stored in artificial saliva for 14 days. Microhardness tests, surface roughness, micromorphology of the enamel and color change analysis were performed at baseline, 7, 14, 21 days of treatment, 7 and 14 days post-treatment. For the statistical analysis, means were compared using the Tukey-Kramer test at a significance level of 5%. As results, the surface roughness test (Ra) presented increase in all experimental groups (PHF, PHH and PHFH) and commercial groups DW and WC in function of time. The microhardness test (KHN) showed a significant increase for the group PHH and a significant reduction on DW group, while the other groups did not show statistical difference in function of timespan study. For the color change analysis test, all the groups presented bleaching effectiveness, except the group NC, and the PHH group was the only one that showed similar values compared to the commercial bleaching agents at all times of study. In the morphological analysis, changes were observed as the presence of porosities in most groups, except on NC group, and deposition of hydroxyapatite crystals on groups PHH and PHFH. It was concluded that the bleaching treatment containing hydroxyapatite provided color changes similar to commercial bleaching agents, was able to increase the microhardness values, and that when this component is formulated with or without fluoride, it can lead to an increase in surface roughness due to deposition of hydroxyapatite crystals over the enamel surface, as observed by analysis of scanning electron microscopy / Mestrado / Dentística / Mestre em Clínica Odontológica

Page generated in 0.0373 seconds