• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 23
  • 8
  • 5
  • 5
  • 3
  • 2
  • 1
  • 1
  • Tagged with
  • 55
  • 55
  • 12
  • 10
  • 10
  • 10
  • 9
  • 8
  • 8
  • 7
  • 6
  • 6
  • 6
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Microsystème pour la nanomédecine : application aux maladies nosocomiales et à la détection des agents pathogènes / Microsystem for Nanomedicine : Application to nosocomial diseases and detection of pathogens

Kahlouche, Karima 19 December 2018 (has links)
Ce travail a pour objet l’étude et le développement d’un capteur électrochimique pour la détection sélective quantitative des analytes biologiques à l’échelle nano. Il se divise en deux parties après une présentation de l’état de l’art sur les maladies nosocomiales et les capteurs électrochimiques. Tout d’abord, nous avons développé un protocole spécifique qui repose sur la fonctionnalisation localisée de la microélectrode de travail par dépôt électrophorétique d'oxyde de graphène réduit/polyéthylènimine (rGO/PEI) pour amplifier le signal de détection. Le microsystème réalisé en salle blanche, a été exploité avec succès pour la détection sélective de la dopamine avec une limite de détection de 50 nM.Ensuite, nous avons utilisé la même plateforme constituée d’électrodes de plus grande taille (mm) pour la réalisation d’un capteur immunologique. Il a démontré son efficacité, de manière spécifique et sélective, pour discriminer la souche sauvage E. Coli UTI89 de UTI89 Δfim (sans opéron), avec une limite de détection de 10 cfu mL−1. En outre, le concept d’utilisation d’une électrode modifiée par rGO/PEI par la modification covalente avec des anticorps pathogènes est général. Il peut être facilement adapté à toute autre espèce pathogène, rendant l’approche générique. Le capteur a donc abouti à des résultats intéressants en milieu aqueux, sérique et urinaire, ce qui est essentiel pour son utilisation potentielle pour le diagnostic clinique des maladies pathogènes. / The purpose of this work concerns the study and development of an electrochemical sensor for both quantitative and selective detection of biological analytes at the nanoscale. It is divided into two parts after a presentation of the state of the art on nosocomial diseases and electrochemical sensors. First, we have developed a specific protocol based on the localized functionalization of the working microelectrode by electrophoretic deposition. The strategy is based on the localizedfunctionalization of the working microelectrode by electrophoretic deposition of reduced graphène oxide / polyethyleneimine (rGO / PEI) to amplify the detection signal. The microsystem built in a clean room has been successfully tested for the selective detection of dopamine with a detection limit of 50 nM. In addition, the microsystem showed good performance in detecting dopamine levels.Then, we have also used the same electrode platform at a larger scale (mm) for the specific and selective detection of the immunological sensor which has demonstrated its effectiveness in distinguishing the UTI89 E. Coli wild-type strain of UTI89 Δfim (without operon), with a detection limit of 10. cfu mL-1. In addition, the concept of rGO / PEI modified electrode by covalent modification with pathogenic antibodies is general and can be easily transposed to any other pathogenic species, making the approach very versatile and generic.The sensor works in aqueous, serum and urinary media, which is essential for its potential use in clinical diagnosis of pathogenic diseases.
52

Bio-encapsulation d'oxydases et de déshydrogénases par électrogénération sol-gel sur réseau de nano-objets / Bioencapsulation of oxidases and dehydrogenases using electrochemically-assisted sol-gel deposition on the nanoobjects network

Mazurenko, Ievgen 03 June 2013 (has links)
Dans cette thèse, des travaux de recherche ont été menés pour immobiliser différentes enzymes (oxydases et déshydrogénases) au sein d'une matrice de silice dans le but de construire un biocapteur ampérométrique. Des matériaux nanostructurés ont ensuite été introduit dans ce système afin d'améliorer les caractéristiques analytiques de ces biocapteurs. La méthode de dépôt sol-gel par assistance électrochimique a été choisie pour l'immobilisation des enzymes à la surface des électrodes et des nanomatériaux car elle donne la possibilité de contrôler finement l'épaisseur du film déposé afin de couvrir individuellement ces objets. La faisabilité de cette approche a été montrée par la modification de nanofibres de platine présentant une grande surface active pour l'oxydation de H2O2 produit en présence de biocomposite silice-glucose oxidase. Le dépôt sol-gel électrochimiquement assisté permet également la modification d'électrodes imprimées en or par un biocomposite silice-choline oxidase, ce qui donne la possibilité de construire rapidement un biocapteur à choline présentant de très bonnes caractéristiques analytiques. Les nanotubes de carbone ont également été choisis comme matrice pour l'immobilisation de déshydrogénases car ils permettent d'obtenir une grande aire spécifique et des propriétés catalytiques intéressantes pour l'oxydation du co-facteur enzymatique NADH. La méthode de dépôt électrophorétique a été utilisée pour créer des couches de nanotubes poreuses ayant une épaisseur contrôlée à la surface d'un support de carbone vitreux. Les électrodes ainsi préparées présentent de bonne performances électrochimiques, permettant notamment de déplacer le potentiel d'oxydation de NADH et d'augmenter la sensibilité de détection. Un biocomposite silice-sorbitol déshydrogénase a ensuite été déposé à la surface de la couche de nanotubes de carbone en utilisant la méthode de dépôt sol-gel assisté par électrochimie pour construire un biocapteur à sorbitol. La méthode de dépôt électrophorétique a enfin été appliquée pour la première fois à l'élaboration d'assemblages de nanotubes de carbone macroporeux. De tells assemblages ont été utilisés comme support pour co-immobiliser la sorbitol déshydrogénase et le co-facteur enzymatique au sein des macropores, ce qui a permis d'augmenter la sensibilité de la détection du sorbitol par comparaison avec un assemblage de nanotubes de carbone non macroporeux / In this thesis, the research work was focused on the immobilization of different enzymes (oxidases and dehydrogenases) into biocomposite silica matrix with the aim of amperometric biosensors construction. Then, the structured nanomaterials were introduced in the system in order to improve the characteristics of biosensors. The method of electrochemically-assisted deposition was chosen for the immobilization of enzymes on the surface of nanomaterials as it provides possibility of fine tuning of film thickness allowing covering each individual nanoobject. The feasibility of this was shown while modifying the platinum nanofibers, which demonstrate high electroactive surface and H2O2 oxidation rate, with silica-glucose oxidase biocomposite. The electrochemically-assisted deposition also allows the express modification of gold screen-printed electrodes with silica-choline oxidase biocomposite making possible the quick fabrication of cheap choline biosensors with high analytical characteristics. The carbon nanotubes was chosen as matrix for the immobilization of dehydrogenases as they have high surface area and electrocatalytic properties towards the oxidation of enzymatic co-factor NADH. The method of electrophoretic deposition was used for the creation of porous CNT-layer with controllable thickness on the surface of glassy carbon electrode. Created thereby matrix demonstrated good electrochemical performance significantly shifting the potential and increasing sensitivity of NADH oxidation. Then the biocomposite silica-sorbitol dehydrogenase film was deposited on the CNT-layer by means of electrochemically-assisted deposition for the construction of high-performance sorbitol biosensor. The method of electrophoretic deposition was also applied for the first time for the construction of thick macroporous CNT-assemblies with uniform pore size using template approach. Such macroporous CNT-electrode was used for the co-immobilization of sorbitol dehydrogenase and enzymatic co-factor inside the pores demonstrating higher sensitivity of sorbitol detection in comparison with nonporous CNT-electrode
53

Keramische Membranen auf Basis LPS-SiC: Schlickerentwicklung und Beschichtungsverfahren

Piwonski, Michael 23 December 2005 (has links) (PDF)
Die Filtration unter aggressiven Einsatzbedingungen, z.B. Einsatz in korrosiven Medien, Abgasfiltration, stellt besondere Anforderungen an das Filtermaterial. Sogenanntes "Liquid Phase Sintered Silicon Carbide" (LPS-SiC) erfüllt die Anforderungen sehr gut. Deshalb bestand das Ziel der Arbeit besteht darin, erstmals aus LPS-SiC asymmetrische keramische Membranen (grobporöses Substrat mit dünner, feinporiger Membran) herzustellen. Als Additivsystem fanden Yttriumoxid und Aluminiumoxid Verwendung. Es wurde Siliciumcarbid der Körnung F1200 auf Substrat der Körnung F500 abgeschieden. Dem Herstellungsverfahren kommt für die Qualität der Membran eine große Bedeutung zu. Daher wurden in dieser Arbeit folgende Beschichtungsmethoden untersucht, um die optimale Methode zu identifizieren: Tauchbeschichtung, elektrophoretische Abscheidung, Druckfiltration und Einsatz von Transfertapes (Transfertapes: Mischung aus Polyacrylatkleber und Pulver). Im Mittelpunkt stand dabei die Druckfiltration. Hierfür wurde eine neue Apparatur konzipiert und aufgebaut. Für die schlickerbasierten Methoden wurde ein wässriges System entwickelt, bei dem auf den Einsatz von organischen Hilfsstoffen verzichtet werden konnte. Die elektrostatische Stabilisierung konnte durch gezieltes Anlösen von Yttriumoxid, Ausfällen von feinskaligem Yttriumhydroxid und Belegung des Siliciumcarbids mit dem Yttriumhydroxid erreicht werden. Die Elektrophorese führte zu keinen befriedigenden Ergebnissen aufgrund des undefinierten spezifischen Widerstandes des Substrats (siehe Dissertation Jan Ihle, Bergakademie Freiberg 2004). Die Druckfiltration erwies sich als das geeignetste Verfahren. Mit ihr konnten ohne Einschränkungen hochwertige Membranen erzeugt werden. Druck und Zeit sind bei gegebenen Feststoffgehalt frei wählbar. Der Druck wurde zwischen 2*10E4 und 1*10E5 Pa variiert. Höherer Druck führte zu feineren Porengrößen (mittlere und maximale Porengröße). Mit der Druckfiltration konnten Membranen ohne makroskopische Defekte erzeugt werden. Sie führte im Vergleich aller Verfahren zu der geringsten Rauhtiefe der Membranen. Die Tauchbeschichtung ließ sich in diesem System nur über den Feststoffgehalt steuern. Membranen aus der Tauchbeschichtung wiesen makroskopische Fehler (große oberflächliche Poren) auf. Die Methode führte hinsichtlich Porengrößen und Rauhtiefe zu den schlechtesten Werten. Die Transfertape-Methode als neuartiger Ansatz erwies sich für das LPS-SiC System als noch nicht ausgereift. Das direkte Bekleben der Substrate war möglich. Hinsichtlich der Membrandicke sind aber Grenzen bei ca. 50 µm gesetzt. Darüber hinaus reißen die Membranen. Es wurden Schwankungen in der Entbinder- und Sinterschwindung verzeichnet. Weiterhin werden große Hohlräume im Substrat nicht von den Transfertapes abgeformt. Beide Effekte erhöhen die Spannungen beim Sintern, so dass bei geringeren Schichtdicken Risse entstehen. / Silicon Carbide (SiC) fulfills many requirements, e.g. a high robustness in terms of corrosion, which makes it a suitable Material for ceramic membranes. The aim of this work was to produce ceramic membranes out of porous liquid phase sintered Silicon Carbide (LPS-SiC). As additives Alumina and Yttria were used. The SiC based on commercial abrasive powders F1200 (Membrane) and F500 (Substrate). Different techniques of membrane formation were applied in order to find the optimum processing procedure: Dip Coating, Electrophoretic Deposition (EPD), Pressure Filtration and the usage of so called Transfer Tapes, a blend of Polyacrylate and ceramic powders). For the slip based methods a water based system was developed without the need of organic additives. A pure electrostatic stabilization was facilitated by solving Yttria with Hydrochloride Acid and precipitation, resulting in the coverage of the SiC particles with finely dispersed Yttria. The EPD was not successful due to a undefined specific resistance of the substrate. The pressure filtration turned out to be the best, most versatile method, leading to defect free membranes with the lowest measured surface roughness. The pressure ranged between 2*10E4 and 1*10E5 Pa. Higher pressure lead to finer pores. The Dip Coating was controlled only by the solids content. Membranes by Dip Coating showed macroscopic defects. As a new concept for ceramic membrane fabrication the Transfer Tapes needed further investigation. The direct gluing on the substrate was possible. The thickness of the membrane was limited to 50 microns in order to keep free of cracks. The Transfer Tapes exhibited pronounced fluctuations in the debinding and sintering shrinkage, leading to increased tension during sintering. Furthermore cavities, (e.g. big pores) were bridged. Both effects lead to increased tension during sintering.
54

Additive Fertigung von Keramiken mittels Mikrofluidik und elektrophoretischer Abscheidung

Vogt, Lorenz 14 January 2021 (has links)
In dieser Dissertation wurde untersucht, inwieweit die Kombination von Mikrofluidik mit elektrophoretischer Formgebung zur additiven Herstellung von Keramikbauteilen genutzt werden kann. Mit Verfahren der Mikrofluidik sollten räumliche Strukturierung und Materialdifferenzierung erfolgen, während die elektrophoretische Abscheidung für die Ausbildung einer homogenen Mikrostruktur sorgt. Es wurde eine Versuchsanlage aufgebaut, die eine kontrollierte elektrophoretische Abscheidung von Keramikpartikeln, die durch eine Hohlelektrode zugeführt werden, auf porösen Membranen ermöglicht. Die Anlage bietet – im Unterschied zu bereits beschriebenen Verfahren – das Potenzial für eine hochgradige Parallelisierung und Multimaterialdruck. Schließlich wurden Finite-Elemente-Modelle zur Feldverteilung und zur Partikelbewegung entwickelt, mit denen die experimentellen Ergebnisse verglichen wurden. Bei den Versuchen traten viele in ihrem Ausmaß nicht erwartete Phänomene auf: elektrohydrodynamische Effekte und nichtelektrisch verursachte Strömungen des Lösungsmittels, die die Ausbeute und Reproduzierbarkeit sowie die Eigenschaften der abgeschiedenen Strukturen verschlechterten, was zusätzlichen Untersuchungen notwendig machte. In Ethanol wurden relevante Abscheideparameter systematisch variiert und die Struktur und das Gefüge der abgeschiedenen Al2O3-Partikel methodisch analysiert. Die Arbeit war Teil eines von der Deutschen Forschungsgemeinschaft geförderten Sachbeihilfe-Projekts (KU 1327/10-1 | RA 614/7-1).:Inhaltsverzeichnis 1 Einleitung 7 2 Stand der Forschung 8 2.1 Stand der Forschung additive Fertigung keramischer Bauteile 8 2.1.1 Feedstockbasierte additive Fertigungsverfahren 9 2.1.2 Pulverbasierte additive Fertigungsverfahren: 10 2.1.3 Schlickerbasierte additive Fertigungsverfahren 11 2.2 Stand der Forschung elektrophoretische Abscheidung 12 2.3 Stand der Forschung Dielektrophorese 15 2.4 Stand der Forschung EHD-Effekt 16 3 Methodisches Vorgehen 19 3.1 Allgemeiner Aufbau 19 3.2 Elektroden 22 3.3 Lösungsmittel 24 3.4 Abscheidemembranen 25 3.5 Partikel und Suspensionen 27 3.6 Durchführung der Depositionsexperimente 30 3.7 Analyse der abgeschiedenen Strukturen 32 3.7.1 Konfokale 3D Laserscanningmikroskopie (CLSM) 32 3.7.2 Dynamische Differenzkalorimetrie und Thermogravimetrie (DSC/TGA) 33 3.7.3 Rasterelektronenmikroskopie (REM) und Varianzanalyse 33 4 Computersimulationen 35 5 Experimentelle Ergebnisse 41 5.1 Untersuchung des EHD-Effekts 41 5.2 Abscheidung mit verschiedenen Lösungsmitteln und Partikeln 45 5.3 Abscheidung von PEI-Aluminiumoxidpartikeln in Ethanol 51 5.4 DSC-TGA einer bedruckten Membran 60 5.5 Varianzanalyse der Gefügehomogenität elektrophoretisch abgeschiedener Proben 63 6 Zusammenfassung und Ausblick 66 7 Quellenverzeichnis 69 8 Formelverzeichnis 78 9 Tabellenverzeichnis 78 10 Abbildungsverzeichnis 79 11 Anhang 83 / In this dissertation it was examined to what extent the combination of microfluidics with electrophoretic shaping can be used for the additive manufacturing of ceramic components. The spatial structuring and material differentiation should take place using microfluidic methods, while the electrophoretic deposition ensures the formation of a homogeneous microstructure. A test facility was set up that enables controlled electrophoretic deposition of ceramic particles, which are fed through a hollow electrode, onto porous membranes. In contrast to known processes, the system offers the potential for high-quality parallelization and multi-material printing. Finally, finite element models for field distribution and particle movement were developed, with which the experimental results were compared. During the experiments, many phenomena that were not expected occurred: electrohydrodynamic effects and non-electrically induced solvent flows, which reduced the yield and reproducibility as well as the properties of the deposited structures, that made additional studies necessary. We systematically varied relevant deposition parameters in the solvent ethanol and the microstructure of the deposited Al2O3 particles was methodically analyzed. The work was part of a research grant project funded by the German Research Foundation (KU 1327 / 10-1 | RA 614 / 7-1).:Inhaltsverzeichnis 1 Einleitung 7 2 Stand der Forschung 8 2.1 Stand der Forschung additive Fertigung keramischer Bauteile 8 2.1.1 Feedstockbasierte additive Fertigungsverfahren 9 2.1.2 Pulverbasierte additive Fertigungsverfahren: 10 2.1.3 Schlickerbasierte additive Fertigungsverfahren 11 2.2 Stand der Forschung elektrophoretische Abscheidung 12 2.3 Stand der Forschung Dielektrophorese 15 2.4 Stand der Forschung EHD-Effekt 16 3 Methodisches Vorgehen 19 3.1 Allgemeiner Aufbau 19 3.2 Elektroden 22 3.3 Lösungsmittel 24 3.4 Abscheidemembranen 25 3.5 Partikel und Suspensionen 27 3.6 Durchführung der Depositionsexperimente 30 3.7 Analyse der abgeschiedenen Strukturen 32 3.7.1 Konfokale 3D Laserscanningmikroskopie (CLSM) 32 3.7.2 Dynamische Differenzkalorimetrie und Thermogravimetrie (DSC/TGA) 33 3.7.3 Rasterelektronenmikroskopie (REM) und Varianzanalyse 33 4 Computersimulationen 35 5 Experimentelle Ergebnisse 41 5.1 Untersuchung des EHD-Effekts 41 5.2 Abscheidung mit verschiedenen Lösungsmitteln und Partikeln 45 5.3 Abscheidung von PEI-Aluminiumoxidpartikeln in Ethanol 51 5.4 DSC-TGA einer bedruckten Membran 60 5.5 Varianzanalyse der Gefügehomogenität elektrophoretisch abgeschiedener Proben 63 6 Zusammenfassung und Ausblick 66 7 Quellenverzeichnis 69 8 Formelverzeichnis 78 9 Tabellenverzeichnis 78 10 Abbildungsverzeichnis 79 11 Anhang 83
55

Keramische Membranen auf Basis LPS-SiC: Schlickerentwicklung und Beschichtungsverfahren

Piwonski, Michael 13 December 2005 (has links)
Die Filtration unter aggressiven Einsatzbedingungen, z.B. Einsatz in korrosiven Medien, Abgasfiltration, stellt besondere Anforderungen an das Filtermaterial. Sogenanntes "Liquid Phase Sintered Silicon Carbide" (LPS-SiC) erfüllt die Anforderungen sehr gut. Deshalb bestand das Ziel der Arbeit besteht darin, erstmals aus LPS-SiC asymmetrische keramische Membranen (grobporöses Substrat mit dünner, feinporiger Membran) herzustellen. Als Additivsystem fanden Yttriumoxid und Aluminiumoxid Verwendung. Es wurde Siliciumcarbid der Körnung F1200 auf Substrat der Körnung F500 abgeschieden. Dem Herstellungsverfahren kommt für die Qualität der Membran eine große Bedeutung zu. Daher wurden in dieser Arbeit folgende Beschichtungsmethoden untersucht, um die optimale Methode zu identifizieren: Tauchbeschichtung, elektrophoretische Abscheidung, Druckfiltration und Einsatz von Transfertapes (Transfertapes: Mischung aus Polyacrylatkleber und Pulver). Im Mittelpunkt stand dabei die Druckfiltration. Hierfür wurde eine neue Apparatur konzipiert und aufgebaut. Für die schlickerbasierten Methoden wurde ein wässriges System entwickelt, bei dem auf den Einsatz von organischen Hilfsstoffen verzichtet werden konnte. Die elektrostatische Stabilisierung konnte durch gezieltes Anlösen von Yttriumoxid, Ausfällen von feinskaligem Yttriumhydroxid und Belegung des Siliciumcarbids mit dem Yttriumhydroxid erreicht werden. Die Elektrophorese führte zu keinen befriedigenden Ergebnissen aufgrund des undefinierten spezifischen Widerstandes des Substrats (siehe Dissertation Jan Ihle, Bergakademie Freiberg 2004). Die Druckfiltration erwies sich als das geeignetste Verfahren. Mit ihr konnten ohne Einschränkungen hochwertige Membranen erzeugt werden. Druck und Zeit sind bei gegebenen Feststoffgehalt frei wählbar. Der Druck wurde zwischen 2*10E4 und 1*10E5 Pa variiert. Höherer Druck führte zu feineren Porengrößen (mittlere und maximale Porengröße). Mit der Druckfiltration konnten Membranen ohne makroskopische Defekte erzeugt werden. Sie führte im Vergleich aller Verfahren zu der geringsten Rauhtiefe der Membranen. Die Tauchbeschichtung ließ sich in diesem System nur über den Feststoffgehalt steuern. Membranen aus der Tauchbeschichtung wiesen makroskopische Fehler (große oberflächliche Poren) auf. Die Methode führte hinsichtlich Porengrößen und Rauhtiefe zu den schlechtesten Werten. Die Transfertape-Methode als neuartiger Ansatz erwies sich für das LPS-SiC System als noch nicht ausgereift. Das direkte Bekleben der Substrate war möglich. Hinsichtlich der Membrandicke sind aber Grenzen bei ca. 50 µm gesetzt. Darüber hinaus reißen die Membranen. Es wurden Schwankungen in der Entbinder- und Sinterschwindung verzeichnet. Weiterhin werden große Hohlräume im Substrat nicht von den Transfertapes abgeformt. Beide Effekte erhöhen die Spannungen beim Sintern, so dass bei geringeren Schichtdicken Risse entstehen. / Silicon Carbide (SiC) fulfills many requirements, e.g. a high robustness in terms of corrosion, which makes it a suitable Material for ceramic membranes. The aim of this work was to produce ceramic membranes out of porous liquid phase sintered Silicon Carbide (LPS-SiC). As additives Alumina and Yttria were used. The SiC based on commercial abrasive powders F1200 (Membrane) and F500 (Substrate). Different techniques of membrane formation were applied in order to find the optimum processing procedure: Dip Coating, Electrophoretic Deposition (EPD), Pressure Filtration and the usage of so called Transfer Tapes, a blend of Polyacrylate and ceramic powders). For the slip based methods a water based system was developed without the need of organic additives. A pure electrostatic stabilization was facilitated by solving Yttria with Hydrochloride Acid and precipitation, resulting in the coverage of the SiC particles with finely dispersed Yttria. The EPD was not successful due to a undefined specific resistance of the substrate. The pressure filtration turned out to be the best, most versatile method, leading to defect free membranes with the lowest measured surface roughness. The pressure ranged between 2*10E4 and 1*10E5 Pa. Higher pressure lead to finer pores. The Dip Coating was controlled only by the solids content. Membranes by Dip Coating showed macroscopic defects. As a new concept for ceramic membrane fabrication the Transfer Tapes needed further investigation. The direct gluing on the substrate was possible. The thickness of the membrane was limited to 50 microns in order to keep free of cracks. The Transfer Tapes exhibited pronounced fluctuations in the debinding and sintering shrinkage, leading to increased tension during sintering. Furthermore cavities, (e.g. big pores) were bridged. Both effects lead to increased tension during sintering.

Page generated in 0.12 seconds