• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 10
  • Tagged with
  • 10
  • 10
  • 6
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo comparativo dos processos eletroqu?micos oxidativos avan?ados (PEOAs) no tratamento de efluentes contendo corantes org?nicos de dif?cil degrada??o / Comparative study of oxidative process electrochemical advanced (PEOAS) in treating wastewater containing organic dyes hard to decay

Solano, Aline Maria Sales 02 July 2015 (has links)
Submitted by Automa??o e Estat?stica (sst@bczm.ufrn.br) on 2016-07-06T19:31:44Z No. of bitstreams: 1 AlineMariaSalesSolano_TESE.pdf: 4891520 bytes, checksum: da7eefacf64cc710af8c295780904937 (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2016-07-06T21:35:58Z (GMT) No. of bitstreams: 1 AlineMariaSalesSolano_TESE.pdf: 4891520 bytes, checksum: da7eefacf64cc710af8c295780904937 (MD5) / Made available in DSpace on 2016-07-06T21:35:58Z (GMT). No. of bitstreams: 1 AlineMariaSalesSolano_TESE.pdf: 4891520 bytes, checksum: da7eefacf64cc710af8c295780904937 (MD5) Previous issue date: 2015-07-02 / Corantes org?nicos t?m sido amplamente utilizados em diversos ramos das ind?strias de tingimento. Esses compostos s?o conhecidos por serem bastante t?xicos, mutag?nicos, carcinog?nico al?m de causarem polui??o est?tica e danos irrevers?veis aos ecossistemas aqu?ticos e a sa?de humana. Estes s?o considerados contaminantes recalcitrantes devido a sua elevada estabilidade e resist?ncia a bio e foto degrada??o. Diante deste contexto, a busca por tecnologias capazes de minimizar os efeitos provocados por esses poluentes se faz necess?ria. Nas ultimas d?cadas os Processos Eletroqu?micos Oxidativos Avan?ados (PEOA?s) baseados na gera??o de esp?cies fortemente oxidantes (radicais ?OH) oferecem abordagens promissoras para a preven??o dos problemas provocados por efluentes industriais. O presente trabalho analisou a degrada??o e mineraliza??o dos corantes t?xteis e o estudo de um efluente real, a fim de avaliar a viabilidade dos PEOA?s tais como Eletrofeton (EF), Fotoeletro-Fenton (FEF) e Oxida??o An?dica (OA), bem como a implementa??o de Fotoeletro-Fenton Solar (FEFS) em uma planta pr?-piloto, a fim de estudar o tratamento eletroqu?mico em escala industrial. No estudo desenvolvido foram comparados o efeito dos PEOA?s na remo??o da cor, decaimento do COT e cin?tica de degrada??o dos compostos e, ainda para o VC utilizando o SFEFS foram realizados estudos da Efici?ncia de Corrente de Mineraliza??o (ECM). Os melhores resultados se deram com o tratamento do FEF para todos os corantes estudados. A partir dos resultados obtidos foi poss?vel eleger o FEF como m?todo mais eficiente e promissor para aplica??o do tratamento quando comparado aos demais m?todos de tratamento, al?m de comprovar a partir do FEFS que o processo pode ser utilizado em escalas industriais, uma vez que esse m?todo FEF foi aperfei?oado e a irradia??o solar substituiu a l?mpada UVA. / Organic dyes have been widely used in various branches of dyeing industries. These compounds are known to be very toxic, mutagenic, cancinogenic only cause aesthetic pollution and irreversible damage to aquatic ecosystems and human health. Are recalcitrant contaminants due to its high stability and resistance to photobleaching and bio. Given this context, the search for technologies that can minimize the effects of such pollutants is required. In recent decades the Electrochemical Oxidation Process Advanced (PEOAs) based on the generation of strongly oxidizing species (radicals ?OH) offer promising approaches for the prevention of problems caused by industrial effluents. This study analyzed the degradation and mineralization of textile dyes and the study of a real effluent in order to assess the feasibility of PEOAs: Electro-Fenton (EF), Photo Electro-Fenton (PEF) and anodic oxidation (AO), and these methods still was studied the Solar Fotoelectro-Fenton (SPEF) in a pre-pilot plant, in order to study the electrochemical treatment on an industrial scale. In the study has compared the effect of PEOAs in the removal of color, TOC and decay kinetics of degradation of the compounds, and also for using the Congo Red (CR) SPEF studies were performed mineralization current efficiency (MCE). The best results are given to the treatment of the PEF for all the studied dyes. From the results it was possible to choose the PEF as the most effective and promising for application of treatment when compared to other methods of treatment, and prove from SPEF that the process can be used in industrial scales, since this method PEF has been improved and solar irradiation replaced the UVA lamp.
2

Estudo da influ?ncia de diferentes grupos funcionais em corantes t?xteis na aplica??o de processos eletroqu?micos oxidativos avan?ados (PEOAs) para descolora??o e remedia??o dos seus efluentes

Soares, Izabelle Cristina da Costa 25 November 2016 (has links)
Submitted by Automa??o e Estat?stica (sst@bczm.ufrn.br) on 2017-06-02T19:23:37Z No. of bitstreams: 1 IzabelleCristinaDaCostaSoares_DISSERT.pdf: 2041673 bytes, checksum: 6a5dc94b62fca433977fd1524cd40197 (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2017-06-05T23:13:43Z (GMT) No. of bitstreams: 1 IzabelleCristinaDaCostaSoares_DISSERT.pdf: 2041673 bytes, checksum: 6a5dc94b62fca433977fd1524cd40197 (MD5) / Made available in DSpace on 2017-06-05T23:13:43Z (GMT). No. of bitstreams: 1 IzabelleCristinaDaCostaSoares_DISSERT.pdf: 2041673 bytes, checksum: 6a5dc94b62fca433977fd1524cd40197 (MD5) Previous issue date: 2016-11-25 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior (CAPES) / A qualidade da ?gua, assim como sua polui??o, tem gerado grande inquieta??o na comunidade cient?fica. Esta problem?tica tem sido acompanhada pelo crescente interesse p?blico, gerando uma demanda pol?tica para legislar de forma mais rigorosa os limites de emiss?o e conte?dos de poluentes nas ?guas. A ind?stria t?xtil tem sido uma das causadoras da polui??o ambiental, principalmente em raz?o da gera??o de uma vasta quantidade de res?duos, devido ? elevada carga org?nica e intensa colora??o de sua produ??o. Os corantes org?nicos, utilizados extensivamente em diversos ramos da ind?stria de t?xtil, s?o conhecidos por serem bastante t?xicos, mutag?nicos e carcinog?nicos, al?m de causarem polui??o est?tica e danos irrevers?veis aos ecossistemas aqu?ticos e a sa?de humana. Dentro deste contexto, tecnologias eletroqu?micas de tratamento de ?gua s?o altamente promissoras para a descolora??o global de efluentes tingidos de corante, tal como demonstrado em v?rios estudos sobre a tem?tica. Portanto, no presente estudo, foi comparado alguns Processos Eletroqu?micos Oxidativos Avan?ados (PEOAs), Oxida??o Eletroqu?mica e Eletro-Fenton, e a sua potencialidade na descolora??o e na remedia??o dos efluentes t?xteis contaminados, assim como a influ?ncia de diferentes grupos funcionais que modificam a estrutura do corante condicionando a descolora??o. Os corantes t?xteis azos reativos Reactive Orange 16, Reactive Violeta 4, Reactive Red 228 e Reactive Black 5 foram escolhidos devido apresentarem a mesma estrutura de base molecular com diferentes grupos funcionais. Os resultados demonstraram que os grupos funcionais que reduzem a nucleofilicidade do poluente, impedem o ataque eletrof?lico do radical hidroxila gerado eletricamente. Deste modo, a efici?ncia global de descolora??o ?, consequentemente, reduzida, bem como a taxa de descolora??o. Al?m disso, a presen?a de uma liga??o crom?foro azo adicional na mol?cula aumenta a elevada resist?ncia dos corantes az?icos como poluentes, devido ? forma??o de um sistema ? conjugado maior e mais est?vel, tornando-se maior a energia de ativa??o necess?ria para o ataque eletrof?lico de ?OH e tamb?m afetando o desempenho de metodologias eletroqu?micas na descolora??o de efluentes. / The water quality as well as its pollution, has caused great concern in the scientific community. The textile industry has been one of causing environmental pollution, mainly due to the generation of a large amount of waste due to the high organic load and intense color of their production. Within this context, electrochemical water treatment technologies are highly promising to achieve complete decolorization of dyebath effluents, as demonstrated by several studies reported in the literature. Therefore, in the present study, we compared different Processes Electrochemical Advanced Oxidation (EOAPs) and their potential in discoloration of contaminated textile effluents, as well as discoloration to the influence of different functional groups which modify the dyestuff structure (Reactive Orange 16, Reactive Violet 4, Reactive Red 228 and Reactive Black 5). The results demonstrate that the functional groups that reduce the nucleophilicity of the pollutant hinder the electrophilic attack of electrogenerated hydroxyl radical. Thereby, the overall decolorization efficiency is consequently reduced as well as the decolorization rate. Moreover, the presence of an additional chromophore azo bond in the molecule enhances the recalcitrant character of the azo dyes as pollutants due to the formation of a larger and more stable conjugated ? system, becoming greater the activation energy required for the electrophyilic attack of ?OH and also affecting the performance of electrochemical technologies on effluents decolorization.
3

Estudo da degradação do metil parabeno utilizando processos Fenton, foto-Fenton e eletro-Fenton / Study of methyl paraben degradation using Fenton, photo-Fenton and electro-Fenton processes

Güere, Carlos Dante Gamarra 15 April 2014 (has links)
Os disruptores endócrinos são frequentemente relatados na literatura como contaminantes de ambientes aquáticos. Por isso, os processos oxidativos avançados (POAs) têm sido estudados como alternativa para o tratamento em meio aquoso. Os POAs consistem na oxidação de compostos orgânicos por radicais hidroxilas com alto poder oxidante. Diante desses aspectos, o presente trabalho tem como principal objetivo o estudo da degradação do metil parabeno (MeP) por processos Fenton, utilizando planejamento experimental e a análise dos modelos matemáticos, possibilitando a avaliação da influência das variáveis e determinando as melhores condições. As degradações de 300 mL de 100 mg L-1 de MeP com o processo Fenton foram realizadas em um reator de vidro onde as concentrações ótimas foram: 16 mg L-1 de Fe2+, 62 mg L-1 de H2O2, pH = 3, agitação constante e 30°C chegando a 100% de degradação em 20 minutos. Para o foto-Fenton, as degradações foram de 500 mL de 100 mg L-1 de MeP em um reator com lâmpada de mercúrio de 4 W , utilizando-se uma concentração de 4 mg L-1 de Fe2+ e 52 mg L-1 de H2O2, pH = 3, 30°C e agitação constante chegando a 100% de degradação em 16 minutos. Finalmente a degradação de 300 mL de 100 mg L-1 de MeP por eletro- Fenton foi realizada em um reator, com 4 mg L-1 de Fe2+, com densidade de corrente (j = 25 mA cm-2) para a produção de H2O2 com eletrodos ADE(cátodo), platina(ânodo), 0,05 mol L-1 de Na2SO4 como eletrólito suporte, pH = 3, sob agitação constante e 30°C chegando a 100% de degradação em 11 minutos. A eficiência da degradação de MeP foi monitorada por espectroscopia UV-VIS e cromatografia liquida de alta eficiência (CLAE) e, a mineralização, pelo monitoramento do carbono orgânico total (COT). / Endocrine disruptors are frequently reported in the literature as contaminants of aquatic environments. Therefore, the advanced oxidation processes (AOPs) have been studied as an alternative to aqueous media treatments. AOPs involve the oxidation of organic compounds by hydroxyl radicals with high oxidation power. Considering these aspects, the aim of the present work is to study the methyl paraben (MeP) degradation by Fenton processes using experimental design and analysis of mathematical models, allowing the evaluation of the influence of variables and determining the best conditions. The degradation of 300 mL of 100 mg L-1 of MeP with Fenton process was performed in a glass reactor where the optimal concentrations were 16 mg L-1 of Fe2+, 62 mg L-1 of H2O2, pH = 3, constant stirring and T = 30°C, reaching 100 % degradation in 20 minutes . For the photo-Fenton degradations were 500 mL of 100 mg L-1 of MeP in a reactor with a mercury lamp with 4 W, using concentration of 4 mg L-1 of Fe2+, 52 mg L-1 of H2O2, pH = 3 , T = 30°C and constant stirring, reaching 100 % biodegradation in 16 minutes. Finally, the degradation of 300 mL of 100 mg L-1 of MeP by electro-Fenton was carried out in a reactor with 4 mg L-1 of Fe2+ with current density (j = 25 mA cm-2) for the production of H2O2 with ADE electrodes (cathode), platinum (anode), 0.05 mol L-1 Na2SO4 as supporting electrolyte, pH = 3, T = 30°C and constant stirring, to reaching 100 % degradation in 11 minutes. The degradation efficiency of MeP was monitored by UV- VIS spectroscopy and liquid chromatography (HPLC) and mineralization, by monitoring the total organic carbon (TOC).
4

Estudo da degradação do metil parabeno utilizando processos Fenton, foto-Fenton e eletro-Fenton / Study of methyl paraben degradation using Fenton, photo-Fenton and electro-Fenton processes

Carlos Dante Gamarra Güere 15 April 2014 (has links)
Os disruptores endócrinos são frequentemente relatados na literatura como contaminantes de ambientes aquáticos. Por isso, os processos oxidativos avançados (POAs) têm sido estudados como alternativa para o tratamento em meio aquoso. Os POAs consistem na oxidação de compostos orgânicos por radicais hidroxilas com alto poder oxidante. Diante desses aspectos, o presente trabalho tem como principal objetivo o estudo da degradação do metil parabeno (MeP) por processos Fenton, utilizando planejamento experimental e a análise dos modelos matemáticos, possibilitando a avaliação da influência das variáveis e determinando as melhores condições. As degradações de 300 mL de 100 mg L-1 de MeP com o processo Fenton foram realizadas em um reator de vidro onde as concentrações ótimas foram: 16 mg L-1 de Fe2+, 62 mg L-1 de H2O2, pH = 3, agitação constante e 30°C chegando a 100% de degradação em 20 minutos. Para o foto-Fenton, as degradações foram de 500 mL de 100 mg L-1 de MeP em um reator com lâmpada de mercúrio de 4 W , utilizando-se uma concentração de 4 mg L-1 de Fe2+ e 52 mg L-1 de H2O2, pH = 3, 30°C e agitação constante chegando a 100% de degradação em 16 minutos. Finalmente a degradação de 300 mL de 100 mg L-1 de MeP por eletro- Fenton foi realizada em um reator, com 4 mg L-1 de Fe2+, com densidade de corrente (j = 25 mA cm-2) para a produção de H2O2 com eletrodos ADE(cátodo), platina(ânodo), 0,05 mol L-1 de Na2SO4 como eletrólito suporte, pH = 3, sob agitação constante e 30°C chegando a 100% de degradação em 11 minutos. A eficiência da degradação de MeP foi monitorada por espectroscopia UV-VIS e cromatografia liquida de alta eficiência (CLAE) e, a mineralização, pelo monitoramento do carbono orgânico total (COT). / Endocrine disruptors are frequently reported in the literature as contaminants of aquatic environments. Therefore, the advanced oxidation processes (AOPs) have been studied as an alternative to aqueous media treatments. AOPs involve the oxidation of organic compounds by hydroxyl radicals with high oxidation power. Considering these aspects, the aim of the present work is to study the methyl paraben (MeP) degradation by Fenton processes using experimental design and analysis of mathematical models, allowing the evaluation of the influence of variables and determining the best conditions. The degradation of 300 mL of 100 mg L-1 of MeP with Fenton process was performed in a glass reactor where the optimal concentrations were 16 mg L-1 of Fe2+, 62 mg L-1 of H2O2, pH = 3, constant stirring and T = 30°C, reaching 100 % degradation in 20 minutes . For the photo-Fenton degradations were 500 mL of 100 mg L-1 of MeP in a reactor with a mercury lamp with 4 W, using concentration of 4 mg L-1 of Fe2+, 52 mg L-1 of H2O2, pH = 3 , T = 30°C and constant stirring, reaching 100 % biodegradation in 16 minutes. Finally, the degradation of 300 mL of 100 mg L-1 of MeP by electro-Fenton was carried out in a reactor with 4 mg L-1 of Fe2+ with current density (j = 25 mA cm-2) for the production of H2O2 with ADE electrodes (cathode), platinum (anode), 0.05 mol L-1 Na2SO4 as supporting electrolyte, pH = 3, T = 30°C and constant stirring, to reaching 100 % degradation in 11 minutes. The degradation efficiency of MeP was monitored by UV- VIS spectroscopy and liquid chromatography (HPLC) and mineralization, by monitoring the total organic carbon (TOC).
5

Avaliação do processo de tratamento de chorume do aterro sanitário de Jardim Gramacho utilizando a técnica de Eletro-Fenton / Process evaluation of treatment of leachate from Jardim Gramacho landfill using electro-fenton process

Alan de Oliveira Teixeira 29 February 2012 (has links)
Este trabalho compara a utilização do tratamento eletrolítico e do tratamento Eletro-Fenton, em corrente alternada (CA), no chorume proveniente do aterro de Gramacho, no estado do Rio de Janeiro. O tratamento eletrolítico consiste em utilizar eletrodos de Fe em contato com a eletricidade, que em pH adequado, sofrem dissolução formando o agente coagulante in situ. O tratamento Eletro-Fenton consiste na geração de um dos componentes do reagente de Fenton pelo método eletrolítico. Nesse trabalho o reagente de Fenton é formado pelos íons ferro gerados pelo tratamento eletrolítico unindo-se ao peróxido de hidrogênio 30% adicionado exteriormente. Amostras do chorume foram caracterizadas pelos parâmetros pH, condutividade, salinidade, temperatura, turbidez, sólidos totais dissolvidos (STD) e Demanda Química de Oxigênio (DQO). O uso do tratamento eletrolítico só mostrou resultados de remoção para DQO e cor. Para garantir um melhor desempenho na remoção de DQO e cor e encontrar valores de remoção para a turbidez foi necessário o uso do tratamento Eletro-Fenton. Alguns parâmetros são importantes no uso dessa técnica, tais como pH, dosagem de peróxido, intensidade de corrente e tempo reacional. Os resultados obtidos para a remoção de DQO, cor e turbidez, foram respectivamente, 74%, 95% e 95%, nas condições operacionais: pH 4, dosagem de 5 mL de peróxido de hidrogênio a 30 %, intensidade de corrente de 2A e tempo reacional de 30 minutos. O tratamento Eletro-Fenton se mostrou mais favorável, pois o tratamento eletrolítico nas mesmas condições operacionais, só apresentou resultado de remoção de DQO que foi de 56%, mesmo sendo o consumo energético idêntico para ambos os processos (0,6 k W h m-3)
6

Avaliação do processo de tratamento de chorume do aterro sanitário de Jardim Gramacho utilizando a técnica de Eletro-Fenton / Process evaluation of treatment of leachate from Jardim Gramacho landfill using electro-fenton process

Alan de Oliveira Teixeira 29 February 2012 (has links)
Este trabalho compara a utilização do tratamento eletrolítico e do tratamento Eletro-Fenton, em corrente alternada (CA), no chorume proveniente do aterro de Gramacho, no estado do Rio de Janeiro. O tratamento eletrolítico consiste em utilizar eletrodos de Fe em contato com a eletricidade, que em pH adequado, sofrem dissolução formando o agente coagulante in situ. O tratamento Eletro-Fenton consiste na geração de um dos componentes do reagente de Fenton pelo método eletrolítico. Nesse trabalho o reagente de Fenton é formado pelos íons ferro gerados pelo tratamento eletrolítico unindo-se ao peróxido de hidrogênio 30% adicionado exteriormente. Amostras do chorume foram caracterizadas pelos parâmetros pH, condutividade, salinidade, temperatura, turbidez, sólidos totais dissolvidos (STD) e Demanda Química de Oxigênio (DQO). O uso do tratamento eletrolítico só mostrou resultados de remoção para DQO e cor. Para garantir um melhor desempenho na remoção de DQO e cor e encontrar valores de remoção para a turbidez foi necessário o uso do tratamento Eletro-Fenton. Alguns parâmetros são importantes no uso dessa técnica, tais como pH, dosagem de peróxido, intensidade de corrente e tempo reacional. Os resultados obtidos para a remoção de DQO, cor e turbidez, foram respectivamente, 74%, 95% e 95%, nas condições operacionais: pH 4, dosagem de 5 mL de peróxido de hidrogênio a 30 %, intensidade de corrente de 2A e tempo reacional de 30 minutos. O tratamento Eletro-Fenton se mostrou mais favorável, pois o tratamento eletrolítico nas mesmas condições operacionais, só apresentou resultado de remoção de DQO que foi de 56%, mesmo sendo o consumo energético idêntico para ambos os processos (0,6 k W h m-3)
7

Degradação eletroquímica dos corantes alimentícios amaranto e tartrazina utilizando H2O2 eletrogerado in situ em eletrodo de difusão gasosa (EDG) modificado com ftalocianina de cobalto (II) e cobre (II) / Electrochemical degradation of the amaranth and tartrazine food dyes using H2O2 electrogenerated in situ in modified gas diffusion electrode(GDE) with copper (II) and cobalt (II) phthalocyanine

Barros, Willyam Róger Padilha 14 August 2014 (has links)
Este trabalho descreve o estudo da geração eletroquímica do H2O2 em eletrólito ácido (H2SO4 (0,1 mol L-1) + K2SO4 (0,1 mol L-1)) e eletrólito alcalino (KOH 1,0 mol L-1) utilizando eletrodo de difusão gasosa (EDG), sendo este fabricado com carbono Printex 6L e modificado com 3,0; 5,0 e 10,0% de ftalocianina de cobalto (II) ou cobre (II). Os experimentos foram realizados em uma célula eletroquímica de compartimento único contendo eletrodo de referência Ag/AgCl, contra eletrodo de Pt e como eletrodo de trabalho foi utilizado o EDG. Nos testes de eletrólise a potencial constante (-0,4 V ≤ E ≤ -1,4 V) durante 90 minutos com O2 pressurizado a 0,2 Bar, a concentração de H2O2 alcançou valor máximo de 178 mg L-1 a - 1,0 V (vs. Ag/AgCl) para o EDG não modificado em eletrólito ácido e em eletrólito alcalino, o valor máximo foi de 3.370 mg L-1 a -1,1 V (vs. Ag/AgCl). Quando incorporada a porcentagem de 5,0% de ftalocianina de cobalto (II) à massa do EGD verificou-se que a concentração de H2O2 alcança valor máximo em 331 mg L-1 a -0,7 V (vs. Ag/AgCl), o que representa um aumento de 86,0% no rendimento da produção de H2O2 em meio ácido, além de uma diminuição de 300 mV no potencial aplicado para formação da espécie oxidante. Para o estudo da degradação eletroquímica foram utilizados os corantes amaranto e tartrazina com concentração de 100 mg L-1. Para o estudo do processo eletro-Fenton homogêneo foram utilizados 0,05; 0,1 e 0,15 mmol de Fe2+ ou Fe3+ e para o processo eletro-Fenton heterogêneo em meio alcalino foi utilizado 0,15 mmol das nanopartículas do tipo Fe3-xCuxO4 (0 ≤ x ≤ 0,25). As eletrólises foram realizadas a potencial constante em -0,7 V (vs. Ag/AgCl) no EDG modificado com 5,0% de ftalocianina de cobalto (II) sob fluxo constante de O2 durante 90 minutos no processo eletro-Fenton homogêneo enquanto no processo eletro-Fenton heterogêneo o EDG não modificado foi utilizado e as eletrólises foram realizadas a -1,1 V (vs. Ag/AgCl). Todos os ensaios eletroquímicos foram realizados em um potenciostato PGSTAT- 302 acoplado a um com módulo de alta corrente BSTR-10A e controlado por meio do software GPES (Metrohm Autolab). As nanopartículas Fe3-xCuxO4 (0 ≤ x ≤ 0,25) foram caracterizadas por Análise de Ativação de Neutrons (AAN), DRX, BET, XPS e MET. As amostras dos corantes foram analisadas por espectrofotometria UV/Vis, cromatografia líquida de alta eficiência (CLAE) e teor de carbono orgânico total (COT). Em termos de descoloração, houve uma pequena diminuição no espectro dos corantes quando utilizado H2O2 eletrogerado em meio ácido o que não ocorre na degradação quando utilizado o processo eletro-Fenton homogêneo sendo mais evidente quando utilizado Fe2+, alcançando uma descoloração máxima de 80,0 e 99,2% respectivamente para os corantes amaranto e tartrazina. O decaimento da concentração por CLAE foi bastante eficiente quando utilizado o processo eletro-Fenton, com melhores resultados para Fe2+ e Fe3-xCuxO4 (x= 0,25) sendo a cinética dos processos de pseudo-primeira ordem. Foram identificados os subprodutos formados durante a degradação dos corantes durante o processo eletro-Fenton homogêneo. Os maiores valores de remoção de COT (67,3%) e consumo energético (CE) (370 kwh kg-1 foram obtidos para o processo utilizando íons Fe2+ e as nanopartículas Fe3-xCuxO4 (x=0,25) respectivamente para o corante amaranto. Os valores da concentração de ferro residual solúvel estão dentro do limite permitido segundo a Resolução CONAMA nº 430/2011. Para o processo eletro-Fenton heterogêneo, a concentração de H2O2 residual e consumida diminuiu e aumentou respectivamente com o aumento do valor de \"x\" na espinela da Fe3-xCuxO4 (0 ≤ x ≤ 0,25). / This work describes the electrogeneration of H2O2 study in acidic medium (H2SO4 (0.1 mol L-1) + K2SO4 (0.1 mol L-1)) and alkaline medium (KOH 1.0 mol L-1) using gas diffusion electrode (GDE), being these GDE manufactured with the Printex 6L carbon and modified with percentages of 3.0, 5.0 and 10.0% of cobalt (II) phthalocyanine or copper (II) phthalocyanine. The experiments were performed in an electrochemical cell single compartment containing the reference electrode Ag/AgCl, platinum counter electrode and the working electrode was used the GDE. In tests electrolysis at constant potential (-0.4 V ≤ E ≤ - 1.4 V) for 90 minutes pressurized with O2 at 0.2 Bar, H2O2 concentration reached a maximum value at 178 mg L-1 to -1.0 V (vs. Ag/AgCl) for GDE unmodified in acid electrolyte and alkaline electrolyte, the maximum value was 3,370 mg L-1 at potential -1.1 V (vs. Ag/AgCl).When incorporated percentage of 5.0% of cobalt (II) phthalocyanine to mass GDE, it is verified that the concentration of H2O2 reaches maximum value at 331 mg L-1 at -0.7 V (vs. Ag/AgCl), which represents increase in yield of 86.0% relative to Printex 6L carbon in acidic medium, addition to a decrease of 300 mV at potential applied to the formation of oxidizing species. To study the electrochemical degradation were amaranth and tartrazine dyes with concentration of 100 mg L-1. To study the homogeneous electro-Fenton process were used 0.05; 0.1 e 0.15 mmol de Fe2+ or Fe3+ and to heterogeneous electro-Fenton process in alkaline medium was used 0.15 mmol of Fe3-xCuxO4 (0 ≤ x ≤ 0.25) nanoparticles. The electrolysis were performed at constant potential -0.7 V (vs. Ag/AgCl) in the GDE modified with 5.0% of cobalt (II) phthalocyanine under constant flow of O2 for 90 minutes in the homogeneous electro-Fenton process while in the heterogeneous electro-Fenton process, GDE unmodified was used and the electrolysis were performed at -1.1 V (vs. Ag/AgCl). All electrochemical tests were performed using a potentiostat/galvanostat model PGSTAT 302 coupled to a BSTR-10A current booster and controlled by GPES software (Metrohm Autolab). The Fe3-xCuxO4 (0 ≤ x ≤ 0.25) nanoparticles were characterized by Neutron Activation Analysis (NAA), XRD, BET, XPS and TEM. The samples of the dyes were analyzed by spectrophotometry UV/Vis, high performance liquid chromatography (HPLC) and total organic carbon (TOC). In terms of discoloration, was a small decrease in the spectrum of the dye when used H2O2 in acidic medium which doesn\'t occur in the degradation when used homogeneous electro-Fenton process being more evident when used Fe2+, reaching a maximum discoloration of 80.0 and 99.2% respectively for amaranth and tartrazine dyes. The decay concentration by HPLC was very efficient when using the electro-Fenton process with better results for Fe2+ and Fe3-xCuxO4 (0 ≤ x ≤ 0.25) nanoparticles being the kinetics of the process of pseudo-first order. Were identified by-products formed during the degradation of dyes during the homogeneous electro-Fenton process. The higher values of TOC removal (67.3%) and energy consumption (EC) (370 kWh kg-1) were obtained to process using Fe2+ ions and Fe3-xCuxO4 (x= 0.25) nanoparticle respectively for amaranth dye. The values of residual soluble iron concentrations are within the permissible limit according to CONAMA Resolution nº 430/2011. To the heterogeneous electro-Fenton process, the residual and consumed concentration of H2O2 decreased and increased respectively with increasing value of \"x\" in the spinel of Fe3-xCuxO4 (0 ≤ x ≤ 0.25).
8

Degradação eletroquímica dos corantes alimentícios amaranto e tartrazina utilizando H2O2 eletrogerado in situ em eletrodo de difusão gasosa (EDG) modificado com ftalocianina de cobalto (II) e cobre (II) / Electrochemical degradation of the amaranth and tartrazine food dyes using H2O2 electrogenerated in situ in modified gas diffusion electrode(GDE) with copper (II) and cobalt (II) phthalocyanine

Willyam Róger Padilha Barros 14 August 2014 (has links)
Este trabalho descreve o estudo da geração eletroquímica do H2O2 em eletrólito ácido (H2SO4 (0,1 mol L-1) + K2SO4 (0,1 mol L-1)) e eletrólito alcalino (KOH 1,0 mol L-1) utilizando eletrodo de difusão gasosa (EDG), sendo este fabricado com carbono Printex 6L e modificado com 3,0; 5,0 e 10,0% de ftalocianina de cobalto (II) ou cobre (II). Os experimentos foram realizados em uma célula eletroquímica de compartimento único contendo eletrodo de referência Ag/AgCl, contra eletrodo de Pt e como eletrodo de trabalho foi utilizado o EDG. Nos testes de eletrólise a potencial constante (-0,4 V ≤ E ≤ -1,4 V) durante 90 minutos com O2 pressurizado a 0,2 Bar, a concentração de H2O2 alcançou valor máximo de 178 mg L-1 a - 1,0 V (vs. Ag/AgCl) para o EDG não modificado em eletrólito ácido e em eletrólito alcalino, o valor máximo foi de 3.370 mg L-1 a -1,1 V (vs. Ag/AgCl). Quando incorporada a porcentagem de 5,0% de ftalocianina de cobalto (II) à massa do EGD verificou-se que a concentração de H2O2 alcança valor máximo em 331 mg L-1 a -0,7 V (vs. Ag/AgCl), o que representa um aumento de 86,0% no rendimento da produção de H2O2 em meio ácido, além de uma diminuição de 300 mV no potencial aplicado para formação da espécie oxidante. Para o estudo da degradação eletroquímica foram utilizados os corantes amaranto e tartrazina com concentração de 100 mg L-1. Para o estudo do processo eletro-Fenton homogêneo foram utilizados 0,05; 0,1 e 0,15 mmol de Fe2+ ou Fe3+ e para o processo eletro-Fenton heterogêneo em meio alcalino foi utilizado 0,15 mmol das nanopartículas do tipo Fe3-xCuxO4 (0 ≤ x ≤ 0,25). As eletrólises foram realizadas a potencial constante em -0,7 V (vs. Ag/AgCl) no EDG modificado com 5,0% de ftalocianina de cobalto (II) sob fluxo constante de O2 durante 90 minutos no processo eletro-Fenton homogêneo enquanto no processo eletro-Fenton heterogêneo o EDG não modificado foi utilizado e as eletrólises foram realizadas a -1,1 V (vs. Ag/AgCl). Todos os ensaios eletroquímicos foram realizados em um potenciostato PGSTAT- 302 acoplado a um com módulo de alta corrente BSTR-10A e controlado por meio do software GPES (Metrohm Autolab). As nanopartículas Fe3-xCuxO4 (0 ≤ x ≤ 0,25) foram caracterizadas por Análise de Ativação de Neutrons (AAN), DRX, BET, XPS e MET. As amostras dos corantes foram analisadas por espectrofotometria UV/Vis, cromatografia líquida de alta eficiência (CLAE) e teor de carbono orgânico total (COT). Em termos de descoloração, houve uma pequena diminuição no espectro dos corantes quando utilizado H2O2 eletrogerado em meio ácido o que não ocorre na degradação quando utilizado o processo eletro-Fenton homogêneo sendo mais evidente quando utilizado Fe2+, alcançando uma descoloração máxima de 80,0 e 99,2% respectivamente para os corantes amaranto e tartrazina. O decaimento da concentração por CLAE foi bastante eficiente quando utilizado o processo eletro-Fenton, com melhores resultados para Fe2+ e Fe3-xCuxO4 (x= 0,25) sendo a cinética dos processos de pseudo-primeira ordem. Foram identificados os subprodutos formados durante a degradação dos corantes durante o processo eletro-Fenton homogêneo. Os maiores valores de remoção de COT (67,3%) e consumo energético (CE) (370 kwh kg-1 foram obtidos para o processo utilizando íons Fe2+ e as nanopartículas Fe3-xCuxO4 (x=0,25) respectivamente para o corante amaranto. Os valores da concentração de ferro residual solúvel estão dentro do limite permitido segundo a Resolução CONAMA nº 430/2011. Para o processo eletro-Fenton heterogêneo, a concentração de H2O2 residual e consumida diminuiu e aumentou respectivamente com o aumento do valor de \"x\" na espinela da Fe3-xCuxO4 (0 ≤ x ≤ 0,25). / This work describes the electrogeneration of H2O2 study in acidic medium (H2SO4 (0.1 mol L-1) + K2SO4 (0.1 mol L-1)) and alkaline medium (KOH 1.0 mol L-1) using gas diffusion electrode (GDE), being these GDE manufactured with the Printex 6L carbon and modified with percentages of 3.0, 5.0 and 10.0% of cobalt (II) phthalocyanine or copper (II) phthalocyanine. The experiments were performed in an electrochemical cell single compartment containing the reference electrode Ag/AgCl, platinum counter electrode and the working electrode was used the GDE. In tests electrolysis at constant potential (-0.4 V ≤ E ≤ - 1.4 V) for 90 minutes pressurized with O2 at 0.2 Bar, H2O2 concentration reached a maximum value at 178 mg L-1 to -1.0 V (vs. Ag/AgCl) for GDE unmodified in acid electrolyte and alkaline electrolyte, the maximum value was 3,370 mg L-1 at potential -1.1 V (vs. Ag/AgCl).When incorporated percentage of 5.0% of cobalt (II) phthalocyanine to mass GDE, it is verified that the concentration of H2O2 reaches maximum value at 331 mg L-1 at -0.7 V (vs. Ag/AgCl), which represents increase in yield of 86.0% relative to Printex 6L carbon in acidic medium, addition to a decrease of 300 mV at potential applied to the formation of oxidizing species. To study the electrochemical degradation were amaranth and tartrazine dyes with concentration of 100 mg L-1. To study the homogeneous electro-Fenton process were used 0.05; 0.1 e 0.15 mmol de Fe2+ or Fe3+ and to heterogeneous electro-Fenton process in alkaline medium was used 0.15 mmol of Fe3-xCuxO4 (0 ≤ x ≤ 0.25) nanoparticles. The electrolysis were performed at constant potential -0.7 V (vs. Ag/AgCl) in the GDE modified with 5.0% of cobalt (II) phthalocyanine under constant flow of O2 for 90 minutes in the homogeneous electro-Fenton process while in the heterogeneous electro-Fenton process, GDE unmodified was used and the electrolysis were performed at -1.1 V (vs. Ag/AgCl). All electrochemical tests were performed using a potentiostat/galvanostat model PGSTAT 302 coupled to a BSTR-10A current booster and controlled by GPES software (Metrohm Autolab). The Fe3-xCuxO4 (0 ≤ x ≤ 0.25) nanoparticles were characterized by Neutron Activation Analysis (NAA), XRD, BET, XPS and TEM. The samples of the dyes were analyzed by spectrophotometry UV/Vis, high performance liquid chromatography (HPLC) and total organic carbon (TOC). In terms of discoloration, was a small decrease in the spectrum of the dye when used H2O2 in acidic medium which doesn\'t occur in the degradation when used homogeneous electro-Fenton process being more evident when used Fe2+, reaching a maximum discoloration of 80.0 and 99.2% respectively for amaranth and tartrazine dyes. The decay concentration by HPLC was very efficient when using the electro-Fenton process with better results for Fe2+ and Fe3-xCuxO4 (0 ≤ x ≤ 0.25) nanoparticles being the kinetics of the process of pseudo-first order. Were identified by-products formed during the degradation of dyes during the homogeneous electro-Fenton process. The higher values of TOC removal (67.3%) and energy consumption (EC) (370 kWh kg-1) were obtained to process using Fe2+ ions and Fe3-xCuxO4 (x= 0.25) nanoparticle respectively for amaranth dye. The values of residual soluble iron concentrations are within the permissible limit according to CONAMA Resolution nº 430/2011. To the heterogeneous electro-Fenton process, the residual and consumed concentration of H2O2 decreased and increased respectively with increasing value of \"x\" in the spinel of Fe3-xCuxO4 (0 ≤ x ≤ 0.25).
9

Degradação eletroquímica/química dos corantes têxteis Reativo Azul 19 e Reativo Preto 5 utilizando eletrodos de diamante dopado com boro e H2O2 eletrogerado em eletrodo de carbono vítreo reticulado / Electrochemical/chemical degradation of textile dyes Reactive Blue 19 and Reactive Black 5 using boron doped diamond electrodes and H2O2 electrogenerated in reticulated vitreous carbon electrode

Vasconcelos, Vanessa Moura 11 September 2015 (has links)
A problemática envolvendo os efluentes têxteis decorre principalmente da elevada coloração que apresentam, devido à presença de corantes que além de serem quimicamente estáveis, podem ser tóxicos e/ou carcinogênicos. Logo, quando são descartados in natura no meio ambiente causam problemas estéticos e, sobretudo, ambientais mesmo em baixas concentrações, além da possibilidade de serem nocivos à saúde humana e dos animais. Neste contexto, o objetivo deste trabalho foi estudar a degradação eletroquímica de dois corantes têxteis, Reativo Azul 19 (RA-19) e o Reativo Preto 5 (RP-5) via Oxidação Anódica (OA), utilizando ânodos de Diamante Dopado com Boro (DDB) suportados em titânio ou em nióbio, via processo Eletro-Fenton (EF) e pela combinação dos processos com H2O2 eletrogerado e OA (CP), usando um eletrodo de Carbono Vítreo Reticulado (CVR) como cátodo. As degradações foram realizadas em célula eletroquímica de um compartimento e em reator de fluxo do tipo filtro-prensa com dois compartimentos. A eficiência das degradações foi monitorada pelas técnicas de espectrofotometria no UV-VIS, Cromatografia Líquida de Alta Eficiência (CLAE) e análise do teor de Carbono Orgânico Total (COT). As variáveis estudadas foram densidade de corrente (10-100 mA cm-2 em célula e 4-41 mA cm-2 em reator), dopagem do eletrodo de DDB/Ti (5.000 e 15.000 ppm B/C), concentração inicial dos íons Fe2+ (0-0,10 mmol L-1) e dos corantes (10-250 mg L-1). As degradações dos corantes apresentaram uma cinética de pseudo ordem zero; exceto quando o corante RP-5 foi degradado pelo processo EF, sendo o melhor ajuste ao modelo de pseudo primeira ordem. Além disso, em iguais condições eletroquímicas o corante RP-5 foi degradado em menor tempo em relação ao RA-19; sendo que em todos os processos estudados os corantes foram totalmente removidos. Considerando a OA em célula com os eletrodos de DDB/Ti, a degradação foi positivamente influenciada pelo aumento da densidade de corrente e dopagem do eletrodo, especialmente em relação a cinética. Além disso, os corantes RA-19 e RP-5 foram completamente removidos em 35 e 50 min de eletrólise quando 100 mA cm-2 foi aplicada ao eletrodo de DDB/Ti dopado com 15.000 ppm relação B/C. Em 2 h, 37% em mineralização foi observado para ambos os corantes e a toxicidade do RA-19 diminuiu contra as bactérias Vibrio fischeri. Ainda nessa condição total mineralização foi alcançada após 8 h de degradação. A remoção de COT foi favorecida utilizando o reator contendo os eletrodos de DDB/Nb e CVR ao invés da célula eletroquímica, chegando a percentuais de 84 e 82% em 30 e 90 min para os corantes RA-19 e RP-5 que foram removidos em 7,5 e 5 min, respectivamente, quando a densidade de 41 mA cm-2 foi aplicada ao DDB/Nb durante a degradação via exclusivamente OA. Entre os processos realizados no reator, o EF foi o energeticamente mais favorável, promovendo remoção em COT de 60 e 74% para os corantes RA-19 e RP-5 com consumo energético de 204 e 208 kWh kg-1, além disso, a completa remoção dos corantes ocorreu em 15 e 7,5 min, respectivamente, quando o eletrólito continha íons Fe2+ na concentração de 0,10 mmol L-1 e aplicando-se -0,4 V vs Ag/AgCl ao eletrodo de CVR. Na degradação os corantes via CP o RA-19 e RP-5 foram completamente removidos em 30 e 15 min com mineralização de 72 e 82% em 90 min associada a consumos energéticos de 562 e 745 kWh kg-1, respectivamente, quando 41 mA cm-2 foi aplicada ao DDB/Nb. Por fim, concluiu-se que os resultados das degradações dos corantes foram promissores, já que rápida remoção dos corantes foi observada, além da parcial mineralização. Logo os processos propostos podem ser aplicados na remoção dos corantes em água; sendo necessários realizar mais estudos, principalmente em relação ao material eletródico e configuração do sistema eletroquímico visando a aplicação industrial. / The main problem involving the textile wastewater is theirs high coloration since they present dyes, which are chemically stable and can be toxic and/or carcinogenic. Therefore, when the textile wastewater are discarded in nature in the environment, even in low concentrations, they may cause not only aesthetic and environmental problems, but also can be harmful to human and animal health. In this context, the aim of the study was to evaluate the electrochemical degradation of two textile dyes, Reactive Blue 19 (RB-19) and Black 5 (RB-5) via Anodic Oxidation (AO) using as anodes Boron Doped Diamond electrodes (BDD) supported on titanium or niobium, via Electro-Fenton (EF) process and by combination of processes with electrogenerated H2O2 and AO (CP) using a Reticulated Vitreous Carbon electrode (RVC) as cathode. The degradations assays were carried out in an electrochemical cell with one compartment and in a filter-press flow reactor with two compartments. The efficiency of degradation was monitored by UV-VIS spectrophotometry, High Performance Liquid Chromatography (HPLC) and analysis of Total Organic Carbon (TOC). The variables studied were current density (10-100 mA cm-2 for cell and 4-41 mA cm-2 for reactor), doping of the BDD/Ti electrodes (5,000 e 15,000 ppm B/C), initial concentration of the Fe2+ ions (0-0,10 mmol L-1) and dyes (10-250 mg L-1). The kinetic results showed that the removal of dyes followed the model of pseudo zero order; except when the RB-5 dye was degraded by EF process, which the best fitted was to pseudo first order model. Furthermore, for equal conditions the RB-5 was degraded in less time in comparison to the RB-19. In addition, the dyes were fully removed in all the processes studied. Regarding the AO in cell with BDD/Ti, the degradation was positively influenced by the increasing in current density and doping of the electrode, primarily the kinetics parameters. In addition, total removal of RB-19 and RB-5 was achieved in 35 and 50 min of electrolysis when 100 mA cm-2 was applied to the electrode doped with 15,000 ppm ratio B/C. In 2 h, 37% in mineralization was attained for both dyes and the toxicity effect of the RB-19 decreased against the bacteria Vibrio fischeri. In this condition, total TOC removed was also reached after 8 h. The TOC removal was enhanced using the reactor fitted with BDD/Nb and RVC instead of the electrochemical cell, achieving TOC removal of 84 and 82% in 30 and 90 min for RB-19 and RB-5 which were removed in 7.5 and 5 min, respectively, when 41 mA cm-2 was applied to the BDD/Nb in the degradation exclusively via AO. Among the processes carried out in the reactor, the EF was the energetically most favourable since TOC removal of 60 and 74% for RB-19 and RB-5 with energy consumption of 204 and 208 kWh kg-1 were noted. In addition, the RB-19 and RB-5 were completely removed in 15 and 7.5 min, respectively, when the electrolyte containing 0.10 mmol L-1 of Fe2+ ions and -0.4 V vs Ag/AgCl was applied to CVR electrode. The combination of processes with electrogenerated H2O2 and AO for degradation of the dyes removed the RB-19 and RB-5 in 30 and 15 min with mineralization of 71.6 and 81.8% in 90 min associated to energy consumptions of 562 and 745 kWh kg-1 respectively, when 41 mA cm-2 was applied to BDD/Nb. Therefore, the degradation results of the dyes were promised since quickly removal of the dyes and partial mineralization were observed hence the proposed processes could be used to remove the dyes from water. However, more studies are needed to enable an industrial application, especially regarding the electrode material and configuration of the electrochemical system.
10

Degradação eletroquímica/química dos corantes têxteis Reativo Azul 19 e Reativo Preto 5 utilizando eletrodos de diamante dopado com boro e H2O2 eletrogerado em eletrodo de carbono vítreo reticulado / Electrochemical/chemical degradation of textile dyes Reactive Blue 19 and Reactive Black 5 using boron doped diamond electrodes and H2O2 electrogenerated in reticulated vitreous carbon electrode

Vanessa Moura Vasconcelos 11 September 2015 (has links)
A problemática envolvendo os efluentes têxteis decorre principalmente da elevada coloração que apresentam, devido à presença de corantes que além de serem quimicamente estáveis, podem ser tóxicos e/ou carcinogênicos. Logo, quando são descartados in natura no meio ambiente causam problemas estéticos e, sobretudo, ambientais mesmo em baixas concentrações, além da possibilidade de serem nocivos à saúde humana e dos animais. Neste contexto, o objetivo deste trabalho foi estudar a degradação eletroquímica de dois corantes têxteis, Reativo Azul 19 (RA-19) e o Reativo Preto 5 (RP-5) via Oxidação Anódica (OA), utilizando ânodos de Diamante Dopado com Boro (DDB) suportados em titânio ou em nióbio, via processo Eletro-Fenton (EF) e pela combinação dos processos com H2O2 eletrogerado e OA (CP), usando um eletrodo de Carbono Vítreo Reticulado (CVR) como cátodo. As degradações foram realizadas em célula eletroquímica de um compartimento e em reator de fluxo do tipo filtro-prensa com dois compartimentos. A eficiência das degradações foi monitorada pelas técnicas de espectrofotometria no UV-VIS, Cromatografia Líquida de Alta Eficiência (CLAE) e análise do teor de Carbono Orgânico Total (COT). As variáveis estudadas foram densidade de corrente (10-100 mA cm-2 em célula e 4-41 mA cm-2 em reator), dopagem do eletrodo de DDB/Ti (5.000 e 15.000 ppm B/C), concentração inicial dos íons Fe2+ (0-0,10 mmol L-1) e dos corantes (10-250 mg L-1). As degradações dos corantes apresentaram uma cinética de pseudo ordem zero; exceto quando o corante RP-5 foi degradado pelo processo EF, sendo o melhor ajuste ao modelo de pseudo primeira ordem. Além disso, em iguais condições eletroquímicas o corante RP-5 foi degradado em menor tempo em relação ao RA-19; sendo que em todos os processos estudados os corantes foram totalmente removidos. Considerando a OA em célula com os eletrodos de DDB/Ti, a degradação foi positivamente influenciada pelo aumento da densidade de corrente e dopagem do eletrodo, especialmente em relação a cinética. Além disso, os corantes RA-19 e RP-5 foram completamente removidos em 35 e 50 min de eletrólise quando 100 mA cm-2 foi aplicada ao eletrodo de DDB/Ti dopado com 15.000 ppm relação B/C. Em 2 h, 37% em mineralização foi observado para ambos os corantes e a toxicidade do RA-19 diminuiu contra as bactérias Vibrio fischeri. Ainda nessa condição total mineralização foi alcançada após 8 h de degradação. A remoção de COT foi favorecida utilizando o reator contendo os eletrodos de DDB/Nb e CVR ao invés da célula eletroquímica, chegando a percentuais de 84 e 82% em 30 e 90 min para os corantes RA-19 e RP-5 que foram removidos em 7,5 e 5 min, respectivamente, quando a densidade de 41 mA cm-2 foi aplicada ao DDB/Nb durante a degradação via exclusivamente OA. Entre os processos realizados no reator, o EF foi o energeticamente mais favorável, promovendo remoção em COT de 60 e 74% para os corantes RA-19 e RP-5 com consumo energético de 204 e 208 kWh kg-1, além disso, a completa remoção dos corantes ocorreu em 15 e 7,5 min, respectivamente, quando o eletrólito continha íons Fe2+ na concentração de 0,10 mmol L-1 e aplicando-se -0,4 V vs Ag/AgCl ao eletrodo de CVR. Na degradação os corantes via CP o RA-19 e RP-5 foram completamente removidos em 30 e 15 min com mineralização de 72 e 82% em 90 min associada a consumos energéticos de 562 e 745 kWh kg-1, respectivamente, quando 41 mA cm-2 foi aplicada ao DDB/Nb. Por fim, concluiu-se que os resultados das degradações dos corantes foram promissores, já que rápida remoção dos corantes foi observada, além da parcial mineralização. Logo os processos propostos podem ser aplicados na remoção dos corantes em água; sendo necessários realizar mais estudos, principalmente em relação ao material eletródico e configuração do sistema eletroquímico visando a aplicação industrial. / The main problem involving the textile wastewater is theirs high coloration since they present dyes, which are chemically stable and can be toxic and/or carcinogenic. Therefore, when the textile wastewater are discarded in nature in the environment, even in low concentrations, they may cause not only aesthetic and environmental problems, but also can be harmful to human and animal health. In this context, the aim of the study was to evaluate the electrochemical degradation of two textile dyes, Reactive Blue 19 (RB-19) and Black 5 (RB-5) via Anodic Oxidation (AO) using as anodes Boron Doped Diamond electrodes (BDD) supported on titanium or niobium, via Electro-Fenton (EF) process and by combination of processes with electrogenerated H2O2 and AO (CP) using a Reticulated Vitreous Carbon electrode (RVC) as cathode. The degradations assays were carried out in an electrochemical cell with one compartment and in a filter-press flow reactor with two compartments. The efficiency of degradation was monitored by UV-VIS spectrophotometry, High Performance Liquid Chromatography (HPLC) and analysis of Total Organic Carbon (TOC). The variables studied were current density (10-100 mA cm-2 for cell and 4-41 mA cm-2 for reactor), doping of the BDD/Ti electrodes (5,000 e 15,000 ppm B/C), initial concentration of the Fe2+ ions (0-0,10 mmol L-1) and dyes (10-250 mg L-1). The kinetic results showed that the removal of dyes followed the model of pseudo zero order; except when the RB-5 dye was degraded by EF process, which the best fitted was to pseudo first order model. Furthermore, for equal conditions the RB-5 was degraded in less time in comparison to the RB-19. In addition, the dyes were fully removed in all the processes studied. Regarding the AO in cell with BDD/Ti, the degradation was positively influenced by the increasing in current density and doping of the electrode, primarily the kinetics parameters. In addition, total removal of RB-19 and RB-5 was achieved in 35 and 50 min of electrolysis when 100 mA cm-2 was applied to the electrode doped with 15,000 ppm ratio B/C. In 2 h, 37% in mineralization was attained for both dyes and the toxicity effect of the RB-19 decreased against the bacteria Vibrio fischeri. In this condition, total TOC removed was also reached after 8 h. The TOC removal was enhanced using the reactor fitted with BDD/Nb and RVC instead of the electrochemical cell, achieving TOC removal of 84 and 82% in 30 and 90 min for RB-19 and RB-5 which were removed in 7.5 and 5 min, respectively, when 41 mA cm-2 was applied to the BDD/Nb in the degradation exclusively via AO. Among the processes carried out in the reactor, the EF was the energetically most favourable since TOC removal of 60 and 74% for RB-19 and RB-5 with energy consumption of 204 and 208 kWh kg-1 were noted. In addition, the RB-19 and RB-5 were completely removed in 15 and 7.5 min, respectively, when the electrolyte containing 0.10 mmol L-1 of Fe2+ ions and -0.4 V vs Ag/AgCl was applied to CVR electrode. The combination of processes with electrogenerated H2O2 and AO for degradation of the dyes removed the RB-19 and RB-5 in 30 and 15 min with mineralization of 71.6 and 81.8% in 90 min associated to energy consumptions of 562 and 745 kWh kg-1 respectively, when 41 mA cm-2 was applied to BDD/Nb. Therefore, the degradation results of the dyes were promised since quickly removal of the dyes and partial mineralization were observed hence the proposed processes could be used to remove the dyes from water. However, more studies are needed to enable an industrial application, especially regarding the electrode material and configuration of the electrochemical system.

Page generated in 0.0553 seconds