• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 31
  • 1
  • Tagged with
  • 34
  • 12
  • 7
  • 6
  • 6
  • 6
  • 6
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Precipitação química associada aos processos de tratamento de lixiviados

Rocha, Etiene Elayne Meireles da 30 July 2013 (has links)
Submitted by Daniella Sodre (daniella.sodre@ufpe.br) on 2015-04-10T14:36:23Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) TESE Etiene Elayne Meireles da Rocha.pdf: 3233442 bytes, checksum: cd4ae7a7d4bec4820b3970f8c67f756a (MD5) / Made available in DSpace on 2015-04-10T14:36:24Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) TESE Etiene Elayne Meireles da Rocha.pdf: 3233442 bytes, checksum: cd4ae7a7d4bec4820b3970f8c67f756a (MD5) Previous issue date: 2013-07-30 / FACEPE; CNPq/FINEP / O tratamento de lixiviados de aterros de resíduos sólidos urbanos tornou-se um desafio no planejamento e elaboração de projetos de dimensionamento de sistemas de tratamento de lixiviados a serem implantados. Diante deste fato pertinente, este trabalho propõe-se à avaliação do tratamento de lixiviados provenientes de aterros de resíduos sólidos urbanos, avaliando a precipitação química associada aos processos de biodegradação, eletrocoagulação e radioativos. Neste trabalho avaliou-se o processo de precipitação química com hidróxido de cálcio, no lixiviado proveniente dos Aterros de resíduos Sólidos de Aguazinha/PE e Muribeca/PE; o mesmo tratamento foi avaliado com um biocoagulante natural, tendo em sua composição a moringa. Foi também estudado o efeito da radiação gama no lixiviado proveniente do Aterro de Resíduos Sólidos da Muribeca/PE (com e sem pré-tratamento por coagulação), obtendo reduções de cor em 80% e remoção de turbidez de 95%, assim como o processo de eletrocoagulação no lixiviado do aterro da Terra Dura/SE, obtendo remoções de turbidez de 95%. Foi testado o acoplamento da precipitação química à radiação gama, empregando uma fonte de Cobalto 60. Foram também realizados ensaios de biodegradabilidade aeróbia, após a coagulação. Por fim, foi analisado o efeito da coagulação na microbiota do lixiviado, revelando remoções de 100% da população microbiana.
12

Estudo da Eficiência da Eletrocoagulação Aplicada a Efluente da Produção de Bebidas Não Gaseificadas e Não Alcoólicas

FOGACA, F. C. 30 August 2016 (has links)
Made available in DSpace on 2018-08-01T21:58:45Z (GMT). No. of bitstreams: 1 tese_10234_Dissertac a o Fernando Fogac a.pdf: 1885054 bytes, checksum: 330d0f1f3d296b8a77370c64f70b25e8 (MD5) Previous issue date: 2016-08-30 / O presente trabalho teve como principal objetivo estudar uma rota de tratamento para o efluente da produção de bebidas não alcoólicas e não gaseificadas, com uma etapa de eletrocoagulação. Como parâmetros analíticos foram monitorados condutividade, pH, temperatura, DQO e turbidez. Outros parâmetros como densidade de corrente e densidade de carga foram avaliados para otimização dos processos. Foram testados os processos de tratamento: Eletrocoagulação, Eletrocoagulação seguida de Fenton, Eletrofenton e Eletrocoagulação seguida de Fotofenton Solar. O efluente de estudo era proveniente de uma empresa situada no Espírito Santo, que é fabricante de sucos prontos para beber, chás e isotônicos. As características do efluente, tais como a heterogeneidade, a alta concentração de DQO e sua elevada acidez, representam os maiores desafios para o tratamento. As amostras foram coletadas e enviadas ao LQA na UFES para os ensaios de tratamento e posterior análise dos parâmetros físico-químicos. A eletrocoagulação não mostrou rendimento suficiente para ser utilizada como única rotina de tratamento para este efluente, o que fez ser necessária a utilização do reagente fenton em três diferentes processos. O eletrofenton apresentou bons resultados, da ordem de 40% de remoção de DQO, mas o processo mais eficiente foi a eletrocoagulação seguida de fenton com remoções de até 60%. A eletrocoagulação seguida de fotofenton solar foi uma técnica promissora, mas precisa ser otimizada. Com o resultado desta pesquisa foi possível observar que há a viabilidade se aplicar a rota de eletrocoagulação seguida de fenton para o tratamento do efluente de bebidas não alcoólicas e não gaseificadas, desde que se adeque a aparelhagem para a realidade industrial.
13

Clarificação de águas por eletrocoagulação alimentada por sistema fotovoltaico / Water clarification by electrocoagulation powered by photovoltaic system

Mendoza Combatt, Maria Paulina 16 August 2018 (has links)
Submitted by Marco Antônio de Ramos Chagas (mchagas@ufv.br) on 2018-09-28T11:52:43Z No. of bitstreams: 1 texto completo.pdf: 1927441 bytes, checksum: 9491b986a90ab6de8c98036bffd8acf4 (MD5) / Made available in DSpace on 2018-09-28T11:52:43Z (GMT). No. of bitstreams: 1 texto completo.pdf: 1927441 bytes, checksum: 9491b986a90ab6de8c98036bffd8acf4 (MD5) Previous issue date: 2018-08-16 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo geral deste trabalho foi implementar o uso de ferramentas estatísticas na otimização do processo de eletrocoagulação para o tratamento de águas superficiais; comparar os mecanismos de coagulação dominantes na eletrocoagulação com eletrodos de alumínio e no tratamento convencional com sulfato de alumínio; e avaliar técnica e economicamente o uso da eletrocoagulação baseada em energia fotovoltaica como tratamento complementar à remoção de poluentes de águas para consumo humano. Inicialmente os modelos e condições ótimas de operação para a eletrocoagulação foram baseados na metodologia de “superfície de resposta” usando o delineamento composto central. A função “desejabilidade” foi utilizada para encontrar as condições operacionais que levassem ao aumento da remoção de cor aparente, da demanda química de oxigênio (DQO) e da turbidez, de maneira simultânea. Foi possível cumprir o padrão estético/organoléptico estipulado para esta etapa do processo (cor < 15 uH, DQO < 18 e turbidez < 5 uT) considerando três amostras de água (turbidez inicial baixa, média e alta). Em uma segunda etapa, gráficos de isoeficiência para remoção de poluentes foram utilizados para determinar e comparar os mecanismos de coagulação atuantes na coagulação convencional e na eletrocoagulação. Para águas com turbidez inicial baixa o mecanismo de adsorção de cargas mostrou eficiências de remoção maiores nos dois tratamentos estudados. Para águas com turbidez inicial média e alta, o mecanismo de varredura mostrou-se eficiente nas duas tecnologias utilizadas. Na terceira fase, a metodologia de superfície de resposta foi utilizada para desenvolver modelos matemáticos considerando os efeitos dos parâmetros intensidade de corrente e tempo de eletrólise (i.t) sobre a remoção da cor aparente e turbidez de uma amostra de água proveniente do rio Turvo Sujo. As condições de desenho e operação para o sistema integrado eletrocoagulação-sistema fotovoltaico (EC-SF) foram estabelecidas assumindo o conceito de reprodutibilidade das condições quando conhecidos os parâmetros de uma única célula eletrolítica. A metodologia estatística utilizada mostrou-se eficiente para a previsão dos melhores valores do binômio i.t, permitindo o cumprimento do padrão estético/organoléptico (cor < 15 uH e turbidez < 5 uT). O desenho de um sistema EC-SF que suprisse a necessidade de consumo de 50 pessoas foi realizado para avaliação do custo do tratamento. Para isto foram considerados o custo do material do eletrodo e o custo de energia elétrica, obtendo-se um custo de R$ 0,70 m -3 de água clarificada. A correlação existente entre as respostas analisadas permitiu encontrar condições especificas dos parâmetros, auxiliando a determinação de pontos de trabalho seguros na operação. A eletrocoagulação mostrou-se eficiente para clarificar águas naturais com diferentes características de turbidez inicial. No que diz respeito aos mecanismos de coagulação encontrados, para águas com turbidez inicial média e alta, o mecanismo de varredura mostrou-se eficiente nas duas tecnologias utilizadas. No entanto, a amplitude de eficiência de remoção, quando utilizada a coagulação convencional, abrange uma área maior do que quando utilizada a eletrocoagulação. Isto implica em uma maior segurança operacional quando ocorrem eventuais flutuações das características da água bruta, bem como no controle da dosagem de coagulante empregado. A metodologia de superfície de resposta permitiu encontrar condições ótimas para os parâmetros de operação, auxiliando na determinação dos parâmetros relativos às necessidades energéticas e de dimensionamento de um sistema fotovoltaico integrado à célula eletrolítica. Assim é possível instalar o sistema EC-SF em qualquer localização onde existam níveis satisfatórios de irradiação como uma alternativa inovadora que ao mesmo tempo ofereça uma opção sustentável ao tratamento de águas em zonas rurais utilizando energias renováveis. / The general objective of this work was to implement the use of statistical tools in the optimization of the electrocoagulation process in surface waters. Also, to compare the dominant coagulation mechanisms in electrocoagulation with aluminium electrodes and in the conventional treatment with aluminium sulphate. Even, technically and economically evaluate the use of electrocoagulation based on photovoltaic energy as a complementary treatment to pollutants removal from water for human consumption. Initially the models and optimal operating conditions for electrocoagulation were based on the response surface methodology using the central composite design. The desirability function was used to find the operating conditions that lead to increased apparent color removal, Chemistry Oxygen Demand (COD) and turbidity simultaneously. It was possible to comply with the aesthetic / organoleptic standard stipulated for this stage of the process (color <15 uH, COD <18 and turbidity <5 uT) considering the three types of studied waters (initial turbidity; low, medium and high). In a second step, isoefficiency plots for pollutants removal were used to determine and compare the coagulation mechanisms acting on conventional coagulation and electrocoagulation. For waters with low initial turbidity, the adsorption mechanism showed higher removal efficiencies in both studied treatments. For water with medium and high initial turbidity, the scanning mechanism was common in both used technologies. In the third step, the response surface methodology was used to develop mathematical models considering the effects of the current intensity and electrolysis time (i.t) parameters on the apparent colour and turbidity removal of a dirty river water sample. The design and operation conditions for the EC-SF integrated system were established assuming the reproducibility concept of the conditions when the parameters of a single electrolytic cell were known. The used statistical methodology proved to be efficient for predicting the best values of the “i.t” binomial, allowing compliance with the aesthetic / organoleptic standard (colour <15 uC and turbidity <5 Ut). The design of an EC-SF system that met the need for consumption of 50 people was conducted to evaluate the cost of treatment. To this, were considered the cost of the electrode material and the cost of electricity for determining a rate of R$ 0,7 m -3 of clarified water. The correlation between the analysed answers allowed to find specific conditions of the parameters, helping to determine safe working points in the operation. Electrocoagulation was efficient to clarify natural waters with different characteristics of initial turbidity. Regarding the coagulation mechanisms found for water, with medium and high initial turbidity, the scanning mechanism was common in both used technologies. However, the breadth of removal efficiency, when using conventional coagulation, covers a larger area than when using electrocoagulation. This may imply greater operational safety, when eventual fluctuations in the raw water characteristics occur, as well as in the dosage control of the employed coagulant. The response surface methodology allowed finding optimum conditions for the operation parameters, helping to determine the parameters related to the energy requirements and the design of a photovoltaic system integrated to the electrolytic cell. Thus, it is possible to install the EC-SF system in any location where irradiation satisfactory levels are reached. Becoming it in an innovative alternative that offers a sustainable option to the water treatment in rural areas using renewable energies.
14

Microtenotomia por radiofreqüência para o tratamento da doença tendinosa insercional crônica : comparação de 2 técnicas cirúrgicas e resultados preliminares

Silva, Ricardo Canquerini da January 2008 (has links)
Resumo não disponível
15

Microtenotomia por radiofreqüência para o tratamento da doença tendinosa insercional crônica : comparação de 2 técnicas cirúrgicas e resultados preliminares

Silva, Ricardo Canquerini da January 2008 (has links)
Resumo não disponível
16

Microtenotomia por radiofreqüência para o tratamento da doença tendinosa insercional crônica : comparação de 2 técnicas cirúrgicas e resultados preliminares

Silva, Ricardo Canquerini da January 2008 (has links)
Resumo não disponível
17

Combinação de eletrocoagulação e processos oxidativos avançados para o tratamento de efluentes da indústria de produtos capilares / Combination of electrocoagulation and advanced oxidative processes for hair care products industry wastewater treatment

Carmo, Andreiva Lauren Vital do 13 July 2018 (has links)
Submitted by Marco Antônio de Ramos Chagas (mchagas@ufv.br) on 2019-02-25T11:49:18Z No. of bitstreams: 1 texto completo.pdf: 2419538 bytes, checksum: 5a19c5f0ce7bde9f77974f5153ae39e6 (MD5) / Made available in DSpace on 2019-02-25T11:49:18Z (GMT). No. of bitstreams: 1 texto completo.pdf: 2419538 bytes, checksum: 5a19c5f0ce7bde9f77974f5153ae39e6 (MD5) Previous issue date: 2018-07-13 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / As indústrias de higiene pessoal, perfumaria e cosméticos demonstram relevância no mercado consumidor mundial e no cenário econômico brasileiro, apresentando grande diversidade de produtos fabricados. Essas indústrias são responsáveis pela geração de efluentes potencialmente poluidores, com características que podem variar conforme as matérias-primas empregadas e a diversidade de produtos fabricados. Os efluentes das indústrias de produtos capilares, por exemplo, podem apresentar em sua composição poluentes que conferem elevada toxicidade e baixa biodegradabilidade, o que dificulta seu tratamento por processos convencionais. O presente estudo teve como objetivo avaliar o desempenho de um sistema combinado de eletrocoagulação e processo oxidativo avançado como tratamento de efluentes gerados pela indústria de produtos capilares. O processo de eletrocoagulação foi investigado em diferentes condições de operação, para as variáveis pH, tempo de eletrólise e densidade de corrente, com melhores resultados de remoção da DQO e da turbidez obtidos para o tratamento realizado em pH 2, 30 min e 50 A/m2. A eletrocoagulação removeu eficientemente a DQO (88%), DBO (90%), COT (85,5%), O&G (>99,5%), surfactantes aniônicos (98,9%), turbidez (97,3%) e toxicidade aguda a Daphnia similis (99,9%) do efluente bruto. Os processos oxidativos avançados H 2 O 2 /UV e TiO 2 /H 2 O 2 /UV foram investigados em diferentes condições de operação, para as variáveis dose de H 2 O 2 , pH, tempo de irradiação e dose de H 2 O 2 , concentração de TiO 2 , tempo de irradiação, respectivamente. Os melhores resultados de remoção da toxicidade aguda foram obtidos para o processo H 2 O 2 /UV, realizado em pH aproximadamente 4, 30 min de irradiação e dose de 20 mmol/L de H 2 O 2 . O processo H 2 O 2 /UV possibilitou elevada remoção (88,4%) da toxicidade aguda remanescente no efluente previamente tratado por eletrocoagulação e moderada remoção da concentração de surfactantes aniônicos (59,5%). O sistema combinado de eletrocoagulação e processo H 2 O 2 /UV removeu eficientemente a matéria orgânica (remoção de 89,4% da DQO) e a toxicidade aguda (>99,99%), porém a CE50 quantificada no efluente tratado foi 44,8%, indicando toxicidade aguda a Daphnia similis remanescente. A geração de residuais de alumínio e peróxido de hidrogênio nos processos de eletrocoagulação e H 2 O 2 /UV, respectivamente, em concentrações que causam efeitos tóxicos, foi possivelmente responsável pela toxicidade aguda remanescente no efluente tratado. / The various sectors of the personal care products industry are highly relevant in the global consumer market, including Brazil, offering a great diversity of manufactured products. This industry is responsible for generating potentially polluting effluents, with characteristics that vary depending on the raw materials used and the variety of products manufactured. For example, the hair care products sector generates effluents containing substances with high toxicity and low biodegradability, which hinders treatment by conventional processes. This study aimed to evaluate the performance of combined electrocoagulation and advanced oxidation process for hair care products manufacturing wastewater treatment. Electrocoagulation process variables investigated included pH, electrolysis time and current density (A/m2), with better COD and turbidity removals obtained for treatment at pH 2, 30 min and 50 A/m2. Electrocoagulation efficiently removed COD (88%), BOD (90%), TOC (85.5%), oils and grease (>99.5%), anionic surfactants (98.9%), turbidity (97.3%) and acute toxicity to Daphnia similis (99.9%) from the raw effluent. The advanced oxidation processes H 2 O 2 /UV and TiO 2 /H 2 O 2 /UV variables investigated were H 2 O 2 and TiO 2 doses, pH and irradiation time. Highest acute toxicity removal was obtained for the H 2 O 2 /UV process, carried out at pH approximately 4, 30 min irradiation and 20 mmol/L H 2 O 2 . The H 2 O 2 /UV process achieved high removal (88.4%) of the acute toxicity remaining after electrocoagulation and moderate anionic surfactants removal (59.5%). The combined electrocoagulation and H 2 O 2 /UV process system efficiently removed organic matter (89.4% of COD removal) and acute toxicity (>99.99%), but the EC50 measured in the treated effluent was 44.8%, which indicates acute toxicity to Daphnia similis still remained. Generation of residual aluminum and hydrogen peroxide in the electrocoagulation and H 2 O 2 /UV process, respectively, at concentrations that cause toxic effects, was possibly responsible for the remaining acute toxicity in the treated effluent.
18

Otimização do tratamento de efluente de matadouro e frigorífico de suínos pela eletrofloculação e combinação eletrofloculaçào/coagulação orgânica / Treatment optimization of effluent from a swine slaughterhouse and packing plant by eletrofloculation and electrofloculation / organic coagulation combination

Orssatto, Fábio 14 February 2017 (has links)
Made available in DSpace on 2017-07-10T19:24:25Z (GMT). No. of bitstreams: 1 Fabio_ Orssatto.pdf: 2716052 bytes, checksum: ab171ebc4e483c9c113d55a88d8297cf (MD5) Previous issue date: 2017-02-14 / This trial aimed at evaluating the electrofloculation performance and its combination with organic coagulation to treat effluents from a swine slaughterhouse and packing plant. This thesis was written and composed of three papers. The first one reports on the removal of COD, turbidity, color, TKN and total phosphorus in the studied effluent according to the electroflocculation technique. It also optimized variables such as potential differential (pd) and hydraulic retention time (HRT) in a batch reactor of electroflocculation using aluminum electrodes. The second paper aimed at evaluating the removal of COD, turbidity, color and TKN from the effluent by electrochemical technique and optimized variables as electric current and HRT in a continuous flow reactor of electroflocculation using aluminum electrodes. The third paper aimed at evaluating the removal of COD, turbidity, color and TKN in the effluent using the combination of electroflocculation / organic coagulation technique. It also optimized variables such as electric current, HRT and tannin-based coagulant concentration in a batch reactor. The effluent used in this study comes from a swine slaughterhouse in the western region of Paraná. For the first paper, the main results were: maximal removal of 99.28% for turbidity, 98.93% for color, 81.01% for COD, 67.15% for TKN and 99% for total phosphorus. According to the statistical analysis, it was possible to obtain mathematical models as well as removal of analyzed parameters, but phosphorus. When the desirability function was calculated, the best optimized treatment conditions were at 30 minutes for HRT and 20 volts for pd, corresponding to 0.86 A of electric current and a 17.2 mA cm-2 current density. The analysis of residual aluminum in the effluent treated in the essays recorded a high concentration, which varied from 15.254 to 54.291 mg L-1. For each cubic meter (m3) of effluent treated by electroflocculation, 10.75 kWh of electric energy and 0.18036 kg of aluminum were used, with a cost of R$ 7.90 m-3. While for the second paper, the main results were: 74.47% of maximum efficiency for turbidity, 91.76% for color and 61.07% for COD. But the system was not efficient for TKN removal, since the maximum removal percentage was 20%. Based on the statistical analysis, it was possible to obtain mathematical models to remove the analyzed parameters. And, when desirability function was calculated, the best optimized treatment conditions were at 18 minutes for HRT, 1.5 A for electric current and a current density of 16.67 mA cm-2. The residual aluminum analysis recorded a concentration range from 1.21 to 4.61 mg L-1. At each cubic meter (m3) of treated effluent, 5.17 kWh of electrical energy and 0.0938 kg of aluminum were used, with a cost of R$ 3.84 m-3. Finally, the main results of the third paper were: the maximum efficiency of removal for turbidity was 98.37%, color was 97.82%, COD was 64.73% and TKN was 65.57 %. Based on the statistical analyses, it was possible to obtain mathematical models to remove parameters of color and turbidity. And when desirability function was calculated, the best optimized treatment conditions were at 10 minutes for HRT, 0.774 mL L-1 of coagulant concentration based on tannin, 0.68 A for electric current and a 13.6 mA cm-2 current density. When analyzing the residual aluminum in the effluent treated during the studied tests, a concentration range from 0.0 to 2.11 mg L-1 was observed. For each cubic meter (m3) of effluent treated by electrocoleculation / organic coagulation combination, 2.96 kWh for electric energy and 0.0475 kg aluminum were used, resulting in R$ 3.49 m-3 cost. The electroflocculation technique and the combination of electroflocculation and organic coagulation were good alternatives to remove pollutants from the studied effluent from swine slaughterhouse and packing plant. / O objetivo deste trabalho foi avaliar o desempenho da eletrofloculação e da combinação eletrofloculação/coagulação orgânica no tratamento de efluentes de um matadouro e frigorífico de suínos. A presente tese foi desenvolvida na forma de três artigos. O primeiro artigo avaliou remoção da DQO, turbidez, cor, NTK e fósforo total no efluente em estudo a partir da técnica eletrofloculação e otimizou as variáveis diferencial de potencial (ddp) e tempo de detenção hidráulica (TDH) em um reator batelada de eletrofloculação utilizando eletrodos de alumínio. O segundo artigo avaliou remoção da DQO, turbidez, cor e NTK do efluente através da técnica eletroquímica e otimizou as variáveis corrente elétrica e tempo de detenção hidráulica (TDH) em um reator de fluxo contínuo de eletrofloculação utilizando eletrodos de alumínio. Já o terceiro artigo avaliou a remoção de DQO, turbidez, cor e NTK do efluente através da combinação eletrofloculação/coagulação orgânica e otimizou as variáveis corrente elétrica, tempo de detenção hidráulica e concentração de coagulante à base de tanino em um reator batelada. O efluente utilizado no estudo provém de um matadouro e frigorífico de suínos localizado na região Oeste do Paraná. Para o primeiro artigo, os principais resultados foram: remoção de até 99,28 % para turbidez, 98,93 % para cor, 81,01 % para DQO, 67,15% para NTK e 99% para fósforo total. Foram utilizadas análises estatísticas para a obtenção de modelos matemáticos e a remoção dos parâmetros analisados, com exceção do fósforo. Ao se calcular a função da desejabilidade, as condições otimizadas de tratamento foram de 30 minutos para o TDH e 20 volts para a ddp, correspondendo a 0,86 A de corrente elétrica e uma densidade de corrente igual a 17,2 mA cm-2. A análise do alumínio residual no efluente tratado nos ensaios registrou elevada concentração, a qual variou de 15,254 a 54,291 mg L-1. A cada metro cúbico (m3) de efluente tratado através da eletrofloculação, utilizam-se 10,75 kWh de energia elétrica e 0,18036 kg de alumínio com um custo de R$ 7,90 m-3. Para o segundo artigo, os principais resultados foram: 74,47 % de eficiência máxima para turbidez, 91,76 % para cor e 61,07 % para DQO. Para a remoção de NTK, o sistema não se mostrou eficiente, cuja remoção máxima foi de 20%. A partir das análises estatísticas, foi possível a obtenção de modelos matemáticos para remoção dos parâmetros analisados. E, ao se calcular a função da desejabilidade, as condições otimizadas de tratamento foram de 18 minutos para o TDH, 1,5 A para a corrente elétrica e uma densidade de corrente igual a 16,67 mA cm-2. A análise do alumínio residual no efluente tratado nos ensaios registrou uma concentração que variou de 1,21 a 4,61 mg L-1. A cada metro cúbico (m3) de efluente tratado, utilizaram-se 5,17 kWh de energia elétrica e 0,0938 kg de alumínio com custo de R$ 3,84 m-3. Por fim, os principais resultados do terceiro artigo foram: a eficiência máxima de remoção de turbidez foi de 98,37 %, para cor, o resultado foi de 97,82 %, para DQO foi de 64,73 % e para NTK, o resultado foi de 65,57 %. A partir das análises estatísticas, foram obtidos modelos matemáticos para os parâmetros de remoção de cor e turbidez. E, ao se calcular a função da desejabilidade, as condições otimizadas de tratamento foram de 10 minutos para o TDH, 0,774 mL L-1 de concentração do coagulante à base de tanino, 0,68 A para a corrente elétrica e densidade de corrente igual a 13,6 mA cm-2. A análise do alumínio residual no efluente tratado nos ensaios registrou uma concentração que variou de 0,0 a 2,11 mg L-1. A cada metro cúbico (m3) de efluente tratado através da combinação eletrofloculação/coagulação orgânica, foram utilizados 2,96 kWh de energia elétrica e 0,0475 kg de alumínio, com custo de R$ 3,49 m-3. A técnica de eletrofloculação e a combinação entre eletrofloculação e coagulação orgânica apresentaram-se como boas alternativas na remoção de poluentes dos efluentes provindos dos matadouros e frigoríficos de suínos
19

Tratamento eletroquímico de esgotos sanitários / Electrochemical Treatment for Municipal Sewage

Formentini, Diana Fatima 28 February 2012 (has links)
Made available in DSpace on 2017-07-10T15:14:44Z (GMT). No. of bitstreams: 1 Diana Formentini.pdf: 3787958 bytes, checksum: 0c6f648ab36ecd404919056defc52426 (MD5) Previous issue date: 2012-02-28 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / Basic sanitation is a public service with the most deficiency in infrastructure in Brazil, in particular the service of collection and treatment of sewage followed by collection services and waste treatment. The scenary of sanitation in Brazil, especially in the big cities, it becomes increasingly costly and challenging because the population is increasingly concentrated in urban areas. In this regard, it is necessary to adopt minimization and water conservation programs, and the implementation of decentralized treatment systems such as compact units which require a smaller area and offer similar performance. Another concern in the area of sanitation is about the removal efficiency of compounds present in small concentrations in sewage treatment plants as medicines for human and veterinary use, as well as beauty and personal care products. This study aimed to evaluate the efficiency of the electrochemical process (electrocoagulation and electro-oxidation) with three different electrodes (aluminum, iron and graphite) for COD removal in sewage and estimate the energy consumption. Evaluate the electro-oxidation in sewage for the degradation of two drugs (diclofenac and clofibric acid). The aluminum electrodes were more efficient for COD removal and achieved efficiency up to 80% for most of the tests performed. Iron electrodes achieved similar result, but it gives residual color in the effluent. Aluminum electrodes save energy compare with iron and graphite electrodes. The electrochemical process is a promising technique for removal pharmaceutical compounds used in this research. / A maior deficiência do Brasil na área de serviços públicos e infraestrutura é o saneamento básico, em especial o serviço de coleta e tratamento de esgotos sanitários, seguido do serviço de coleta e tratamento de resíduos sólidos. A situação do saneamento básico no Brasil, principalmente nos grandes centros urbanos, torna-se cada vez mais onerosa e desafiadora já que a população está cada vez mais concentrada nas áreas urbanas. Nesse sentido, faz-se necessária a adoção de programas de minimização e conservação de água, além da implantação de sistemas de tratamento descentralizados, como, por exemplo, unidades compactas de tratamento que exigem menor área e oferecem igual desempenho. Outra preocupação na área do saneamento diz respeito à eficiência deremoção de compostos presentes em pequenas concentrações nas estações de tratamento de esgotos como fármacos de uso humano e veterinário, bem como produtos de beleza e higiene pessoal. Dentro desse contexto, o presente trabalho teve como objetivo avaliar a eficiência do Processo Eletroquímico (Eletrocoagulação e Eletro-oxidação) em esgoto sanitário para remoção de DQO, utilizando eletrodos de alumínio, ferro e grafite e estimar o consumo de energia para cada sistema. Avaliou-se ainda o uso da Eletro-oxidação em esgoto sanitário para degradação de dois fármacos (diclofenaco sódico e ácido clofíbrico). A eletrocoagulação com eletrodos de alumínio mostrou-se mais eficiente para remoção de DQO, obtendo eficiências acima 80% para a maioria dos ensaios realizados. Os eletrodos de Ferro apresentaram eficiência semelhante, entretanto, forneceram coloração residual ao efluene final. Os eletrodos de alumínios requerem menor consumo de energia. O processo eletroquímico mostrou-se uma técnica promissora para remoção de determinados compostos farmacêuticos que não sofrem remoção ou degradação pelas técnicas convencionais.
20

Efeitos da radiofreqüência nas características mecânicas da cápsula anterior do ombro de coelhos / Radiofrequency effects on mechanical characteristics of anterior shoulder capsule of rabbits

Raymundo, José Luiz Pozo 17 July 2007 (has links)
INTRODUÇÃO - A literatura mostra a utilização da radiofreqüência como alternativa em casos de redundância ou frouxidão de tecido, podendo ser empregada como solução em alguns casos de instabilidade de ombro. O presente estudo avalia os efeitos mecânicos da radiofreqüência em cápsulas anteriores de ombros de coelhos vivos. MÉTODOS O estudo é comparativo e randomizado, tendo sido realizado em trinta e sete ombros de coelhos, machos, da raça Nova Zelândia, na faixa etária de 4 meses 6 meses, com peso médio de 3kg 250mg, criados para o projeto e mantidos no Biotério Central da Universidade Federal de Pelotas UFPEL - RS. O trabalho consta de dezoito ombros do grupo controle sendo estes abertos para gerar instabilidade e não submetidos ao procedimento de radiofreqüência; e dezenove ombros do grupo experimento (radiofreqüência), abertos para gerar instabilidade e submetidos a radiofreqüência com tempo fixado em 7segundos numa temperatura fixa de 650C, com tecido embebido em solução salina. Após cinqüenta dias de pós operatório, os animais foram levados à eutanásia. O material foi mantido em -21,40C por quinze dias e, após transportado para o Laboratório de Investigação Medica 21 da Universidade de São Paulo USP - SP, para avaliação de nove variáveis: altura, comprimento inicial sem carga, área da cápsula, força máxima, deformação máxima, tensão máxima, deformação relativa, rigidez e módulo de elasticidade. RESULTADOS Foram encontradas diferenças estatisticamente significantes entre os grupos controle e o grupo radiofreqüência, para as variáveis força máxima e rigidez (p<0,05), sendo maiores em média, no grupo controle. CONCLUSÃO Desse modo a força máxima e a rigidez da cápsula anterior de ombros de coelhos vivos, submetidas à radiofreqüência em um único ponto, diminui após cinqüenta dias / INTRODUTION literature presents radiofrequency as an alternative tool to be used in redundancy or tissue looseness cases, and to be employed as a potencial solution for shoulder instability. The present study evaluated the mechanical effects of radiofrequency usage in anterior shoulder capsules of living rabbits. METHODS - the study is comparative and randomized, it was carried out with thirty seven shoulders of male rabbits (New Zealand breed), with ages between 4 to 6 months, weighing on average 3kg250g that were raised for the project and kept at Central Biotery from Federal University of Pelotas RS. The study groups encompassed eighteen shoulders as a control group that were operated to generate instability but were not submitted to radiofrequency procedure; and nineteen shoulders as intervention group (radiofrequency), that underwent the same operation procedure but were submitted to radiofrequency by the period of seven seconds at a steady temperature of 650C, the tissue was Embedded in salt solution. Fifty days after surgery the rabbits were taken to euthanasia. The material was kept at - 21,40C for fifteen days and later was taken to the São Paulo University-USP Medical Investigation Laboratory(#21), for the assessment of nine variables: height, unloaded inicial length, capsule area, maximum strength, maximum deformation, maximum tension, relative deformation, stiffness and elasticity module. RESULTS Statistical differences were observed between groups concerning maximum strength and stiffness(p<0.05), that were higher on average in the contrl group. CONCLUSION Maximum strength and stiffness of the anterior shoulder capsule in living rabbits, submitted to radiofrequency in a single spot, decreases after fifty days

Page generated in 0.0736 seconds