• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 41
  • 2
  • 2
  • 2
  • Tagged with
  • 43
  • 15
  • 14
  • 14
  • 12
  • 12
  • 11
  • 11
  • 11
  • 10
  • 10
  • 10
  • 10
  • 10
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Fonoforese e eletroestimulação neuromuscular em cães: uma contribuição para a fisioterapia veterinaria / Phonophoresis and neuromuscular electrical stimulation in dogs: a contribution to the veterinary phisiotherapy

Pelizzari, Charles 02 March 2011 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The aim of the first study was to evaluate the plasma concentration of diclofenac sodium (DS) in dogs submitted to diclofenac phonophoresis and to evaluate if phonophoresis induces greater absorption of this drug. .Five dogs were used in eight different groups at different times: Group 1, application of ultrasound for six minutes, removal of the ultrasound gel and topical application of two grams of DS gel for six minutes; Group 2, topical application of two grams of DS gel for six minutes; Group 3 topical application of two grams of DS gel and then covering it with common gel to apply ultrasound for six minutes; Group 4, similar to Group 1, but the ultrasound device was switched off; Group 5, similar to Group 3, but the ultrasound device was switched off, Group 6, the application of ultrasound was performed using only two grams of DS; Group 7, similar to Group 6, but the ultrasound device was switched off and Group 8, oral administration of 40mg of DS. The application area was 20cm². It was used a frequency of 1MHz, continuous ultrasound and intensity of 0,4W cm-2. Blood collections were performed before treatment (T0), 1h (T1) and 4h (T2) after ultrasound application for all groups. DS concentrations in plasma were measured by high performance liquid choramatohraphy (HPLC). There was significant increase of DS plasma concentration only at T1 in the Group 8. It was no possible to detect any concentration of DS in the plasma of dogs after topical application of DS, even after DS phonophoresis. The facilitation of transdermal penetration by ultrasound has not been verified under the protocol specified in this research. The aim of the second study was to use medium frequency Neuromuscular Electrical Stimulation (NMES) in femoral quadriceps of dogs with induced muscular atrophy, evaluate the occurrence of gain in mass in these muscles and to compare NMES in different periods of treatment. Eight dogs, weighing between 15 and 25kg, were randomly placed in two groups: GI (NMES for 30min), GII, (NMES for 60min). For the induction of the muscular atrophy, the right femoral-tibial-patellar joint was immobilized for 30 days by the percutaneous transfixation type II method. NMES was carried out in the dogs of groups, three times a week, with an interval of 48h between each session, during 60 days. The parameters measured were: thigh perimetry, knee goniometry, creatine kinase (CK) enzyme activity and morphometry of the muscular fibers in transversal cuts of the vastus lateralis muscle, collected through a muscular biopsy. There was no significant difference regarding the values of thigh perimetry and CK enzyme activity. The goniometry presented a significant increase (P<0.05) in the groups GI and GII at 30 days from the surgical procedure for immobilization when compared with time zero. As for the morphometry of the fibers of the vastus lateralis, a significant increase (P<0.05) was observed in the transversal area of the treated groups GI e GII at 90 days from the surgical procedure for immobilization when compared with time zero. Thus, it can be concluded that NMES of medium frequency brings about hypertrophy of the vastus lateralis muscle in dogs after induced muscular atrophy. NMES for 60min (GII) presents a greater muscular gain related to the GI / Esta tese foi dividida em duas pesquisas distintas utilizando fonoforese e eletroterapia, na primeira pesquisa o objetivo foi constatar a concentração plasmática de diclofenaco sódico emulgel em cães com ou sem o uso de fonoforese e se a fonoforese induz maior absorção deste fármaco. Para a realização da fonoforese foram utilizados cinco cães em oito grupos distintos, denominados: Grupo1: aplicação de ultrassom (US) por 6 minutos, remoção do gel com papel toalha e após aplicação de dois gramas de diclofenaco sódico (DS) emulgel permanecendo por 6 minutos; Grupo2: aplicação de dois gramas de DS emulgel tópico permanecendo por 6 minutos; Grupo3 aplicação de dois gramas de DS emulgel, posteriormente recobrindo-o com gel comum para acoplamento e realizado US pelo tempo de 6 minutos; Grupo4: repetiu-se o protocolo do Grupo1 com o ultrassom desligado; Grupo5: repetiu-se o protocolo do Grupo3 com o ultrassom desligado; Grupo6: aplicação de dois gramas de DS emulgel tópico e realizado diretamente sobre este o US pelo tempo de 6 minutos; Grupo7: repetiu-se o protocolo do Grupo6 com o ultrassom desligado; Grupo8: administração oral de um comprimido de DS (40mg) por animal. A área de aplicação foi de 20cm². A frequência do ultrassom foi de 1MHz, modo contínuo, com intensidade de 0,4W cm-2. Realizou-se a coleta de amostra sanguínea antes de executar os protocolos (Tempo zero), após uma hora (Tempo 1) e após 4 horas da aplicação (Tempo 2) em todos os grupos e posterior análise das mesmas por Cromatografia Líquida de Alta Eficiência (CLAE). Houve diferença (P<0,05) apenas no Tempo 1 do Grupo8. Não foi possível verificar concentração plasmática de diclofenaco sódico com aplicação tópica, em cães submetidos ou não à fonoforese, apenas quantificou-se o diclofenaco sódico pela administração via oral. A facilitação da penetração transdérmica pelo ultrassom não foi verificada sob o protocolo especificado nesta pesquisa. Na segunda pesquisa o objetivo foi avaliar a ocorrência de ganho de massa muscular utilizando a estimulação elétrica neuromuscular de média freqüência (corrente de Kotz 2500Hz) no músculo quadríceps femoral de cães com atrofia muscular induzida e comparar a EENM sob diferentes tempos de tratamento. Para a realização da eletroterapia foram utilizados oito cães, pesando entre 15 e 25kg e distribuídos aleatoriamente em dois grupos denominados de GI (30minutos) e GII (60minutos). Para a indução da atrofia muscular, a articulação fêmoro-tíbio-patelar direita foi imobilizada por 30 dias por transfixação percutânea tipo II. Foi realizada a EENM nos cães dos grupos GI e GII três vezes por semana, com intervalo mínimo de 48 horas entre cada sessão, pelo período de 60 dias. Foram mensuradas a perimetria das coxas, goniometria dos joelhos, atividade da enzima creatina-quinase (CK) e morfometria das fibras musculares do vasto lateral em cortes transversais colhido mediante a biópsia muscular. Não houve diferença quanto aos valores da perimetria da coxa e atividade da enzima CK. A goniometria revelou significância (P<0,05) nos grupos GI e GII entre os tempos zero e 30. Os grupos GI e GII tiveram aumento significativo (P<0,05) da área de secção quando comparados com o dia zero e noventa. Pode-se concluir que a EENM de média freqüência ocasiona hipertrofia do músculo vasto lateral em cães após atrofia muscular induzida. A EENM com duração de 60minutos (GII) promove um maior ganho de massa muscular em relação ao GI.
22

Ação bactericida (in vitro) de gerador de alta frequência sobre culturas bacterianas comumente encontradas em feridas crônicas

Bampi, Gabriela Manosso 23 January 2015 (has links)
Na prática fisioterapêutica utilizam-se diversas técnicas de eletroterapia com finalidades antissépticas e bactericidas. Porém, poucos estudos são encontrados sobre a ação de gerador de alta frequência no tratamento de enfermidades causadoras de contaminação/infecção, como feridas crônicas. Contudo, geradores de alta frequência são conhecido por seu efeito bactericida e antisséptico, graças à produção de ozônio na superfície onde é aplicado. Tendo em vista que o gerador de alta frequência apresenta baixo custo, fácil manuseio e ação potencializadora do processo cicatricial, por meio da sua ação bactericida, a presente dissertação teve como objetivo avaliar o efeito antimicrobiano de gerador de alta frequência sobre as bactérias Staphylococcus aureus, Pseudomonas aeruginosa e Acinetobacter baumannii. Realizou-se testes de tamanho de halo de inibição; contagem de unidades formadoras de colônia, citometria de fluxo usando o kit Live/Dead® para verificar integridade da membrana e rodamina 123 para avaliar o estresse oxidativo e avaliação da temperatura. Conclui-se que o gerador de alta frequência apresenta ação bactericida, sendo, que o tempo e a frequência comportam-se de forma dependente, sua ação é dose-dependente e age de forma mais expressiva em bactérias Gram-negativas, Sua utilização não causa aumento da temperatura local, apenas no eletrodo de vidro e a produção de radicais livres aumenta com o tempo de exposição ao gerador de alta frequência (833Hz), enquanto a viabilidade celular decresce. / Submitted by Ana Guimarães Pereira (agpereir@ucs.br) on 2016-12-09T17:12:27Z No. of bitstreams: 1 Dissertacao Gabriela Manosso Bampi.pdf: 1053473 bytes, checksum: 47b9df5694f5409de46618b2d0f7c98b (MD5) / Made available in DSpace on 2016-12-09T17:12:27Z (GMT). No. of bitstreams: 1 Dissertacao Gabriela Manosso Bampi.pdf: 1053473 bytes, checksum: 47b9df5694f5409de46618b2d0f7c98b (MD5) Previous issue date: 2016-12-09 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / In the physiotherapy practices, various electrotherapy techniques are used with antiseptic and antibacterial purposes; however, few studies are found about the action of high-frequency generator in the treatment of diseases causing contamination/infection, such as chronic wounds; nevertheless, the high-frequency generator is known for its antiseptic and bactericidal effect by producing ozone at the surface where it is applied. Considering that the high-frequency generator is inexpensive, easy handling and potentiating action of the healing process through their bactericidal action, this thesis aims to evaluate the antimicrobial effect of highfrequency generator on bacteria of the genus Staphylococcus aureus, Pseudomonas aeruginosa and Acinetobacter baumannii. To analyzed the action of highfrequency generator the following tests are realizes: inhibition zone size; counting colony forming units, flow cytometry using the kit Live / Dead® to verify membrane integrity and rhodamine 123 to assess oxidative stress and temperature evaluation. Concluding that the high-frequency generator has bactericidal action, time and frequency behave as dependents, revealing its action is dose-dependent and acts more significantly in Gram-negative bacteria. Its use does not cause local temperature increase, only the glass electrode and the free radical production increases with time of exposure to the high-frequency generator (833Hz), while cell viability decreased.
23

A versatile current source for low, middle frequencies and interferential pulse therapies

Oliveira, Paulo Henrique de 27 April 2012 (has links)
Electrical stimulation is an important tool in medicine with applications like muscle rehabilitation, pain management and pacemakers. Portable stimulation devices for home use are divided mainly in two domains: low and middle frequency therapies. Due to the lack, in Germany, of a system to provide both therapies at the same equipment, the main objective of this project is the development of a current source not only capable of that, but also able to generate arbitrary stimulation patterns controlled by an external microcontroller. Moreover, the system should make possible the use of interferential current therapy. The result of the project is an electronic device that triggers current stimulation patterns based on three control signals, which could be easily generated by a microcontroller. The system provides LF stimulation with balanced current pulses up to 80mA through 1k? load impedance, pulse widths between 50 and 1000µs, and frequencies up to 150Hz. It also provides MF stimulation outputs up to 100mApp, with a modulation frequency up to 4kHz and a simple interface to control the envelope waveform. It presents also two galvanic isolated channels to allow interferential current therapy and, when no output current is intended, it is able to provide a short circuit on the load to remove possible net charges introduced by the system to the patient’s body. Additionally, a MATLAB application and a SPICE simulation were developed to assist the creation of control signals. As the system is able to deliver stimulation currents with an arbitrary pattern, it can be used to find the best pulse waveforms for a series of different applications involving electrical therapy, like TENS and MES. / Elektrostimulation ist ein wichiges Hilfsmittel in der Medizin mit Anwendungen im Bereich der Muskelrehabilitation, der Schmerztherapie und in Herzschrittmachrn. Tragbare Stimulatoren zum hauslichen Gebrauch warden hauptsachlich in zwei Gruppen unterteit: Niederfrequenz- und Mittelfrequenztherapiegerate. Bisher gibt es in Deutschland kein Great das beide Therapieformen durchfuhren kann, sodas das Hauptziel dieses Projekts die Entwicklung einer Stromquelle ist, die in der Lage ist, beide Therapieformen anzuwender. Das Great ist zusatzlich in der Lage beiebige, einstellbare Stimulationsmuster zu erzeugen, welche durch einen externen Mikrocontroller gesteuent warden. Auberdem soll disses System Interferenzstromtherapie ermoglichen. Das Ergebnis dieses Projekts ist ein elektronisches Great, das auf drei Steuersignalen basierende Reizstrommuster erzeugt. Diese Steuersignale konnen von einem Mikrocontroller einfach generiert warden. Das System ermoglicht NF-Stimulation mit ausbalancierten Stromimpulsen bis zu 80mA bei 1K? Lastimpedanz, Pulsbreiten zwischen 50 und 1000us und Frequezen bis 150Hz. Es beinhaltet MF-Stimulationsausgange fur bis zu 100mApp Ausgangsstrom, mit Modulationsfrequenzen bis zu 4k Hz und einem einfachen Interface zur Steuerung der Wellenform der Hullkurve. Es bietet zwei galvanische getrennte Kanale zur Interferenzstromtherapie. Falls Kein Ausgangsstrom benotgt wind, konnen die Ausgange Kurzeschlossen warden, um den korper des Patienten vo einer moglichen elektrischen Aufladung das Gerate zu schutzen. Daruber hinaus wurden eine MATLAB application und eine SPICE Simulation entwickelt, um die Erstellung von Steuersignalen zu unterstutzen. Das System Kann beliebige Reiztrommuster erzengen, dadurch eignet es zur Erforschung der optimalen Impulswellenformen vieler verschiedener Elektrotherapien. / 5000
24

A versatile current source for low, middle frequencies and interferential pulse therapies

Oliveira, Paulo Henrique de 27 April 2012 (has links)
Electrical stimulation is an important tool in medicine with applications like muscle rehabilitation, pain management and pacemakers. Portable stimulation devices for home use are divided mainly in two domains: low and middle frequency therapies. Due to the lack, in Germany, of a system to provide both therapies at the same equipment, the main objective of this project is the development of a current source not only capable of that, but also able to generate arbitrary stimulation patterns controlled by an external microcontroller. Moreover, the system should make possible the use of interferential current therapy. The result of the project is an electronic device that triggers current stimulation patterns based on three control signals, which could be easily generated by a microcontroller. The system provides LF stimulation with balanced current pulses up to 80mA through 1k? load impedance, pulse widths between 50 and 1000µs, and frequencies up to 150Hz. It also provides MF stimulation outputs up to 100mApp, with a modulation frequency up to 4kHz and a simple interface to control the envelope waveform. It presents also two galvanic isolated channels to allow interferential current therapy and, when no output current is intended, it is able to provide a short circuit on the load to remove possible net charges introduced by the system to the patient’s body. Additionally, a MATLAB application and a SPICE simulation were developed to assist the creation of control signals. As the system is able to deliver stimulation currents with an arbitrary pattern, it can be used to find the best pulse waveforms for a series of different applications involving electrical therapy, like TENS and MES. / Elektrostimulation ist ein wichiges Hilfsmittel in der Medizin mit Anwendungen im Bereich der Muskelrehabilitation, der Schmerztherapie und in Herzschrittmachrn. Tragbare Stimulatoren zum hauslichen Gebrauch warden hauptsachlich in zwei Gruppen unterteit: Niederfrequenz- und Mittelfrequenztherapiegerate. Bisher gibt es in Deutschland kein Great das beide Therapieformen durchfuhren kann, sodas das Hauptziel dieses Projekts die Entwicklung einer Stromquelle ist, die in der Lage ist, beide Therapieformen anzuwender. Das Great ist zusatzlich in der Lage beiebige, einstellbare Stimulationsmuster zu erzeugen, welche durch einen externen Mikrocontroller gesteuent warden. Auberdem soll disses System Interferenzstromtherapie ermoglichen. Das Ergebnis dieses Projekts ist ein elektronisches Great, das auf drei Steuersignalen basierende Reizstrommuster erzeugt. Diese Steuersignale konnen von einem Mikrocontroller einfach generiert warden. Das System ermoglicht NF-Stimulation mit ausbalancierten Stromimpulsen bis zu 80mA bei 1K? Lastimpedanz, Pulsbreiten zwischen 50 und 1000us und Frequezen bis 150Hz. Es beinhaltet MF-Stimulationsausgange fur bis zu 100mApp Ausgangsstrom, mit Modulationsfrequenzen bis zu 4k Hz und einem einfachen Interface zur Steuerung der Wellenform der Hullkurve. Es bietet zwei galvanische getrennte Kanale zur Interferenzstromtherapie. Falls Kein Ausgangsstrom benotgt wind, konnen die Ausgange Kurzeschlossen warden, um den korper des Patienten vo einer moglichen elektrischen Aufladung das Gerate zu schutzen. Daruber hinaus wurden eine MATLAB application und eine SPICE Simulation entwickelt, um die Erstellung von Steuersignalen zu unterstutzen. Das System Kann beliebige Reiztrommuster erzengen, dadurch eignet es zur Erforschung der optimalen Impulswellenformen vieler verschiedener Elektrotherapien. / 5000
25

Ação bactericida (in vitro) de gerador de alta frequência sobre culturas bacterianas comumente encontradas em feridas crônicas

Bampi, Gabriela Manosso 23 January 2015 (has links)
Na prática fisioterapêutica utilizam-se diversas técnicas de eletroterapia com finalidades antissépticas e bactericidas. Porém, poucos estudos são encontrados sobre a ação de gerador de alta frequência no tratamento de enfermidades causadoras de contaminação/infecção, como feridas crônicas. Contudo, geradores de alta frequência são conhecido por seu efeito bactericida e antisséptico, graças à produção de ozônio na superfície onde é aplicado. Tendo em vista que o gerador de alta frequência apresenta baixo custo, fácil manuseio e ação potencializadora do processo cicatricial, por meio da sua ação bactericida, a presente dissertação teve como objetivo avaliar o efeito antimicrobiano de gerador de alta frequência sobre as bactérias Staphylococcus aureus, Pseudomonas aeruginosa e Acinetobacter baumannii. Realizou-se testes de tamanho de halo de inibição; contagem de unidades formadoras de colônia, citometria de fluxo usando o kit Live/Dead® para verificar integridade da membrana e rodamina 123 para avaliar o estresse oxidativo e avaliação da temperatura. Conclui-se que o gerador de alta frequência apresenta ação bactericida, sendo, que o tempo e a frequência comportam-se de forma dependente, sua ação é dose-dependente e age de forma mais expressiva em bactérias Gram-negativas, Sua utilização não causa aumento da temperatura local, apenas no eletrodo de vidro e a produção de radicais livres aumenta com o tempo de exposição ao gerador de alta frequência (833Hz), enquanto a viabilidade celular decresce. / Conselho Nacional de Desenvolvimento Científico e Tecnológico / In the physiotherapy practices, various electrotherapy techniques are used with antiseptic and antibacterial purposes; however, few studies are found about the action of high-frequency generator in the treatment of diseases causing contamination/infection, such as chronic wounds; nevertheless, the high-frequency generator is known for its antiseptic and bactericidal effect by producing ozone at the surface where it is applied. Considering that the high-frequency generator is inexpensive, easy handling and potentiating action of the healing process through their bactericidal action, this thesis aims to evaluate the antimicrobial effect of highfrequency generator on bacteria of the genus Staphylococcus aureus, Pseudomonas aeruginosa and Acinetobacter baumannii. To analyzed the action of highfrequency generator the following tests are realizes: inhibition zone size; counting colony forming units, flow cytometry using the kit Live / Dead® to verify membrane integrity and rhodamine 123 to assess oxidative stress and temperature evaluation. Concluding that the high-frequency generator has bactericidal action, time and frequency behave as dependents, revealing its action is dose-dependent and acts more significantly in Gram-negative bacteria. Its use does not cause local temperature increase, only the glass electrode and the free radical production increases with time of exposure to the high-frequency generator (833Hz), while cell viability decreased.
26

A colocação dos eletrodos interfere na antihiperalgesia promovida pela tens? / Does placement of electrodes influence tens-induced antihyperalgesia?

Poderoso Neto, Maurício Lima 25 January 2012 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Among the non-pharmacologic therapy resources for inflammatory pain treatment, transcutaneous electric nerve stimulation (TENS) has been gaining attention in the literature. However, the clinical literature on TENS is sometimes difficult to be interpreted due to limitations in clinical trials and little methodological rigor. Another controversial issue is the lack of standardization in the parameters of the current as well as the ways of application of the electrodes, both needing to be better elucidated. Methods: Carrageenan and kaolin were used to (3%) to mimetize knee ostheoarthritis in rats. Twenty-five male Wistar rats were divided according to electrodes location in 5 groups (n=5, in each group): ipsilateral dermatome, contralateral dermatome, paravertebral, acupoints (Bp6 and E36) and control group. The frequency and the duration of the application were the same in all groups. In all groups, thermal and secondary mechanical hyperalgesia, as well as motor performance and joint edema were measured before and after TENS was applied by stimulating rats with 4 Hz,100 μs of pulse duration, at a sensory intensity during 20 minutes. Mechanical withdrawal threshold was tested for the differences between the treatment groups by using Kruskal Wallis followed by Tukey test, Wilcoxon Matched Pairs test for differences into the group and Friedman followed by Turkey test for repeated measures. P values less than 0.05 were considered significant. Results: Following TENS application with electrodes placed on ipsilateral or contralateral dermatome, paraspinal muscles or acupoints, there was a significant reduction in both mechanical and thermal hyperalgesia. Moreover, an increase in time for performing rota rod test when compared to control group and prior TENS was observed in all groups treated with active TENS. However, there was no difference for the edema between groups. The intensity was significantly lower in the contralateral dermatome in comparison to other electrode placements. Results for paw withdrawal latency and threshold and intensity suggest there is a tendency for developing tolerance to TENS after the fifth day of stimulation. Conclusion: It seems that TENS-induced antihyperalgesia does not depend on the electrode placement, indicating TENS acts through the central nervous system. / Dentre as terapêuticas não-farmacológicas para o tratamento da dor inflamatória, vem ganhando destaque na literatura a neuroestimulação elétrica transcutânea (TENS). Entretanto, a literatura clínica sobre TENS é, às vezes, difícil de ser interpretada devido a limitações nos ensaios clínicos e pouco rigor metodológico. Outro fator controverso é a falta de padronização nos parâmetros da corrente assim como nas formas de aplicação dos eletrodos, ambos necessitando ser melhor elucidados. Objetivos: a presente pesquisa teve como objetivo analisar se as diferentes localizações de eletrodos interfeririam na anti-hiperalgesia promovida pela TENS de baixa freqüência em um modelo de dor inflamatória. Métodos: Utilizando-se caolina e carragenina (3%), induziu-se a osteoartrite, modelo de dor inflamatória, em joelhos de ratos. Foram utilizados 25 ratos machos da linhagem Wistar, divididos de acordo com a localização dos eletrodos em 5 grupos (n=5, em cada grupo), sendo eles: dermátomo ipsilateral, dermátomo contralateral, região paravertebral, pontos de acupuntura (Bp6 e E36) e controle. Em todos os grupos, foram mensurados antes e pós a aplicação da corrente a hiperalgesia térmica, a hiperalgesia mecânica secundária e o edema da articulação do joelho. A TENS foi aplicada com a frequência de estimulação de 4 Hz, duração de pulso (100 μs), intensidade sensorial por 20 minutos durante 5 dias consecutivos. Para medidas entre grupos foram utilizados o teste de Kruskal-wallis e ANOVA seguido pelo post hoc teste de Tukey. Para medidas intra grupos foram utilizados os testes de Wilcoxon Matched Pairs e teste t. Os valores de p < 0,05 foram considerados significativos. Resultados: Após a aplicação da TENS com os eletrodos posicionados no dermátomo ipsilateral, dermátomo contralateral, na paravertebral e em pontos de acupuntura, observou-se uma redução significativa na hiperalgesia térmica e na hiperalgesia mecânica quando comparado ao grupo controle e ao pré-tratamento em cada grupo. Entretanto, não houve diferença significativa para a medida do edema articular. A intensidade de estimulação foi significativamente inferior no dermátomo contralateral em comparação aos demais locais de aplicação dos eletrodos. Os dados de latência, limiar mecânico e de intensidade mostram uma tendência a tolerância aos efeitos da TENS a partir do quinto de sua aplicação. Conclusão: Os achados sugerem que o efeito analgésico promovido pela TENS não depende do local de aplicação dos eletrodos, sugerindo ação da TENS no sistema nervoso central.
27

Estudo da regeneração do nervo ciático de rato submetidos à estimulação elétrica após lesão por esmagamento / not available

Mendonça, Adriana Clemente 20 December 2000 (has links)
Uma investigação experimental sobre a influência da estimulação elétrica direta na regeneração do nervo usando uma lesão por esmagamento do nervo ciático de ratos como modelo foi realizada. Quarenta e dois ratos foram utilizados e divididos em quatro grupos, de acordo com o procedimento: 1) Sem lesão e sem estimulação; 2) lesão por esmagamento, sem estimulação; 3) sem lesão, com estimulação; 4) lesão por esmagamento, com estimulação. O nervo ciático foi exposto através de uma incisão lateral na coxa direita e submetido à lesão por esmagamento numa máquina universal de testes com uma carga de 15.000 g concentrada em um segmento de 5 mm por 10 minutos, nos grupos 2 e 4. Um estimulador elétrico foi desenvolvido para liberar uma corrente elétrica contínua de baixa intensidade (1 &#956A). O mesmo foi implantado no espaço subcutâneo próximo a coluna lombar, o ânodo foi colocado proximalmente e o catôdo distalmente ao esmagamento. A recuperação funcional foi avaliada em intervalos semanais até o 21º dia pós-operatório, através do Índice Funcional do Ciático (IFC) e calculada por um programa específico, apresentando melhora progressiva em ambos os grupos com lesão por esmagamento, porém mais acentuada naqueles com estimulação elétrica. Os animais foram sacrificados no 21º dia pós-operatório para análise histológica e morfométrica dos nervos, onde os resultados mostraram aumento da densidade das fibras nervosas mas decréscimo do diâmetro das fibras nervosas, assim como um aumento no número e diâmetro dos vasos sangüíneos intra e extra~fasciculares no grupo estimulado. Similar, mas um menos evidente fenômeno foi observado no grupo sem lesão por esmagamento mas com estimulação elétrica. Concluiu-se que a estimulação elétrica direta de baixa intensidade provoca a regeneração nervosa após lesão por esmagamento em condições controladas e que o IFC é um método confiável para avaliar a recuperação nervosa uma vez que seus resultados aproximam-se do estudo morfométrico. / An experimental investigation of the influence of direct electrical stimulation on nerve regeneration using a crush injury of the sciatic nerve of rats as model was undertaken. Forty two rats were used and divided into four groups according to the procedure carried out: 1) no injury, no stimulation; 2) crush injury, no stimulation; 3) no injury, stimulation; 4) crush injury, stimulation. The sciatic nerve was exposed through a lateral incision on the Iight thigh and submitted to a crush injury in an universal testing machine with a 15000 g load concentrated on a 5 mm-long segment for 10 minutes, in groups 2 and 4. An electrical stimulator was developed to deliver a continuous direct low intensity electrical current (1 &#956A). The device was implanted into the subcutaneous space near the lumbar spine, the anode placed proximally and the cathode distally to the crush injury. Functional recovery was checked at weekly intervals up to the 21st postoperative day, by means of the Sciatic Functional Index (SFI) as calculated by a specific software and showed progressive improvement in both groups with crush injury but more marked in that with electrical stimulation (4). The animals were killed on the 21st post operative day for morphometric and histological examination of the nerves, whose results showed an increased nerve fiber density but decreased nerve fíber diameter, as well as increased number and diameter of intra and extrafascicular blood vessels in the stimulated group. Similar but less marked phenomena were observed in the group without crush injury but with electrical stimulation. It was concluded that low intensity direct electrical stimulation enhances nerve regeneration followíng a crush injury in controlled conditions and that the SFI is a reliable method to evaluate the nerve recovery since its results closely matched those of the morphometric study.
28

Estudo da regeneração do nervo ciático de rato submetidos à estimulação elétrica após lesão por esmagamento / not available

Adriana Clemente Mendonça 20 December 2000 (has links)
Uma investigação experimental sobre a influência da estimulação elétrica direta na regeneração do nervo usando uma lesão por esmagamento do nervo ciático de ratos como modelo foi realizada. Quarenta e dois ratos foram utilizados e divididos em quatro grupos, de acordo com o procedimento: 1) Sem lesão e sem estimulação; 2) lesão por esmagamento, sem estimulação; 3) sem lesão, com estimulação; 4) lesão por esmagamento, com estimulação. O nervo ciático foi exposto através de uma incisão lateral na coxa direita e submetido à lesão por esmagamento numa máquina universal de testes com uma carga de 15.000 g concentrada em um segmento de 5 mm por 10 minutos, nos grupos 2 e 4. Um estimulador elétrico foi desenvolvido para liberar uma corrente elétrica contínua de baixa intensidade (1 &#956A). O mesmo foi implantado no espaço subcutâneo próximo a coluna lombar, o ânodo foi colocado proximalmente e o catôdo distalmente ao esmagamento. A recuperação funcional foi avaliada em intervalos semanais até o 21º dia pós-operatório, através do Índice Funcional do Ciático (IFC) e calculada por um programa específico, apresentando melhora progressiva em ambos os grupos com lesão por esmagamento, porém mais acentuada naqueles com estimulação elétrica. Os animais foram sacrificados no 21º dia pós-operatório para análise histológica e morfométrica dos nervos, onde os resultados mostraram aumento da densidade das fibras nervosas mas decréscimo do diâmetro das fibras nervosas, assim como um aumento no número e diâmetro dos vasos sangüíneos intra e extra~fasciculares no grupo estimulado. Similar, mas um menos evidente fenômeno foi observado no grupo sem lesão por esmagamento mas com estimulação elétrica. Concluiu-se que a estimulação elétrica direta de baixa intensidade provoca a regeneração nervosa após lesão por esmagamento em condições controladas e que o IFC é um método confiável para avaliar a recuperação nervosa uma vez que seus resultados aproximam-se do estudo morfométrico. / An experimental investigation of the influence of direct electrical stimulation on nerve regeneration using a crush injury of the sciatic nerve of rats as model was undertaken. Forty two rats were used and divided into four groups according to the procedure carried out: 1) no injury, no stimulation; 2) crush injury, no stimulation; 3) no injury, stimulation; 4) crush injury, stimulation. The sciatic nerve was exposed through a lateral incision on the Iight thigh and submitted to a crush injury in an universal testing machine with a 15000 g load concentrated on a 5 mm-long segment for 10 minutes, in groups 2 and 4. An electrical stimulator was developed to deliver a continuous direct low intensity electrical current (1 &#956A). The device was implanted into the subcutaneous space near the lumbar spine, the anode placed proximally and the cathode distally to the crush injury. Functional recovery was checked at weekly intervals up to the 21st postoperative day, by means of the Sciatic Functional Index (SFI) as calculated by a specific software and showed progressive improvement in both groups with crush injury but more marked in that with electrical stimulation (4). The animals were killed on the 21st post operative day for morphometric and histological examination of the nerves, whose results showed an increased nerve fiber density but decreased nerve fíber diameter, as well as increased number and diameter of intra and extrafascicular blood vessels in the stimulated group. Similar but less marked phenomena were observed in the group without crush injury but with electrical stimulation. It was concluded that low intensity direct electrical stimulation enhances nerve regeneration followíng a crush injury in controlled conditions and that the SFI is a reliable method to evaluate the nerve recovery since its results closely matched those of the morphometric study.
29

Sistema de eletroestimulação portátil com oito síncronos

Pepino, André Luiz Gonçalves 06 June 2011 (has links)
A Estimulação Elétrica Funcional (EEF), que utiliza pulsos elétricos para a reprodução de movimentos artificialmente, é uma técnica consolidada no tratamento de pacientes em reabilitação. Para tal, são usados equipamentos específicos para a geração destes sinais, chamados de eletroestimuladores. O presente trabalho descreve o desenvolvimento de um eletroestimulador portátil com oito canais independentes e síncronos entre si, permitindo a programação temporal de ativação dos seus canais, o que proporciona a reprodução de movimentos artificiais similares aos reais. O hardware do dispositivo possui dimensões reduzidas (115 mm X 162 mm X 43 mm) e gera estímulos elétricos bifásicos com amplitudes de ±100 mA. Estes pulsos possuem durações de 100 a 800 µs e freqüência de 50 a 1000 Hz. Utilizou-se uma interface em display líquido (LCD) sensível ao toque (touchscreen), para a interação do usuário com o software embarcado, que é responsável por controlar todo o sistema. Um software desktop foi criado para a geração dos programas estimulatórios, contendo também um simulador virtual que por meio de um modelo humano 3D permite ajustes no programa estimulatório antes de executá-lo em um paciente. O equipamento foi desenvolvido de forma a cumprir as normas de segurança elétrica da ABNT referentes a equipamentos eletromédicos para estimulação neuromuscular. Testes in vitro foram feitos seguindo os roteiros descritos nessas normas para garantir a conformidade de seu funcionamento e dos pulsos elétricos fornecidos pelo dispositivo. O equipamento apresentou resultados dentro dos limites de segurança, de temperaturas excessivas, de exatidão de dados de operação, de proteção contra características de saída incorreta e, contra erros humanos. Também, 10 voluntários participaram de testes in vivo com o objetivo de validação clínica do dispositivo. A validação consistiu na comparação de amplitudes de movimento obtidas pelos voluntários em reproduções de movimentos funcionais durante o uso do eletroestimulador desenvolvido e de um comercial. Com erro máximo de 3%, o eletroestimulador desenvolvido foi capaz de executar movimentos funcionais por meio de parâmetros da EEF, podendo ser útil no tratamento de reabilitação física. / The use of electrical pulses for artificial reproduction movements, or Functional Electrical Stimulation (FES), is a consolidated technique for treating patients in rehabilitation. For this use, special instruments are employed to generate the signals, known as electrostimulators. This work describes the development of a portable electrostimulator with eight independent and synchronous channels, allowing a temporal activation program of their channels and making it possible to reproduce artificial movements similar to real ones. The hardware of this device has small dimensions (115 mm X 162 mm X 43 mm) and generates biphasic electrical pulses with maximum amplitudes of ± 100 mA. The pulses have durations from 100 to 800 µs and frequency from 50 to 1000 Hz. Also, there is an interface with a touchscreen liquid crystal display (LCD) for user interaction with the embedded software, which is responsible for controlling the complete system. A desktop software was developed to generate stimulatory programs, containing a virtual simulator that, using a 3D human model, allows adjustments in the stimulatory program before running it on a patient. The instrument complies with the electrical standards of the ABNT relating to electromedical equipment for neuromuscular stimulation. In vitro tests were performed following the rules described in standards to ensure compliance of functioning, and the electrical pulses provided by the device. As a result, the device showed values within the standard limits of safety, excessive temperatures, accuracy of operating data, protection of incorrect output, and human errors. Also, ten volunteers participated of in vivo tests to validate the instrument. The in vivo tests consisted on a comparison of movement ranges obtained by the volunteers in reproduction of functional movements during the use of a commercial electrostimulator and the developed one. With a maximum error of 3%, the developed instrument was capable to perform functional movements, and thus may be useful in treatment of physical rehabilitation.
30

Efeitos da eletroestimulação intravaginal e da eletroestimulação de superfície em mulheres com incontinência urinária de esforço

Correia, Grasiéla Nascimento 03 October 2013 (has links)
Made available in DSpace on 2016-06-02T20:18:21Z (GMT). No. of bitstreams: 1 5505.pdf: 1074978 bytes, checksum: 1a5242e29b80454e7c9d5c62084d3bb8 (MD5) Previous issue date: 2013-10-03 / Financiadora de Estudos e Projetos / Several Studies evaluated the effects of intravaginal electrical stimulation (IVES) in the stress urinary incontinence (SUI) treatment. However, few studies assessed the effects of surface electrical stimulation (SES), which, according to studies, is effective to SUI, cheap, and less embarrassing to the patient. Despite these advantages of SES, the IVES is the most used type of electrotherapy in clinical practice. Moreover, there are not any studies which compared the effects of SES with the ones of IVES treatment, what justifies the importance of this doctoral studies. Two studies were performed. In the STUDY I the objective was to evaluate and compare the effects of SES e IVES in women with SUI. In the STUDY II, the objective was to verify the effects of SES in the pelvic floor muscle (PFM) electrical activity. In order to performe these studies, were included 45 women, with SUI and who were more than 50 years old. These volunteers were randomized in three groups: intravaginal electrical stimulation group (IVESG, n=15), surface electrical stimulation group (SESG, n=15), and control group (CG, n=15). The IVESG used intravaginal electrode in the treatment and the SESG performed the electrical stimulation with four silicone electrodes, bilaterally fixed in ischial tuberosity and suprapubic region. Both, IVESG and SESG performed 12 sessions of treatment (equipment Dualpex 961), with the same parameters. The CG did not receive any treatment during the corresponding time. In the STUDY I, the volunteers from all the groups performed the evaluation before and after the treatment. In which was performed the 1-hour pad test, the quality of life with the King s Health Questionnaire ad the evaluation of PFM function and pressure with the equipment (Peritron 9300). The STUDY II, which included the SESG and the CG, evaluated SUI severity by the 1-hour pad test, the PFM electrical activity and the quality of life with the International Consultation on Incontinence Questionnaire - Short Form (ICIQ-SF). The result of STUDY I show that the SES and IVES improved the SUI, PFM pressure and the quality of life. In the STUDY II was verified that the SES treatment also improved the PFM electrical activity. With the result of these studies it is possible to conclude that the SES and the IVES show a similar results and, therefore, both are important option of SUI treatment. / Estudos avaliaram os efeitos do tratamento de eletroestimulação intravaginal (EEIV) para a incontinência urinária de esforço (IUE), entretanto poucos estudos avaliaram os efeitos da eletroestimulação de superfície (EES) que, de acordo com estudos, é um tratamento efetivo para a IUE, de baixo custo e menos constrangedor à paciente. Apesar destas vantagens da EES, a EEIV ainda é o tipo de eletroterapia mais utilizada na prática clínica e não existe estudo que comparou os efeitos do tratamento de EES com a EEIV, o que justifica a importância desta tese de doutorado. Foram realizados dois estudos, o ESTUDO I teve o objetivo de avaliar e comparar os efeitos da EES e da EEIV em mulheres com IUE, e no ESTUDO II o objetivo foi verificar os efeitos da EES na atividade elétrica dos músculos do assoalho pélvico (MAP). Para realizar estes estudos foram incluídas 45 mulheres com mais de 50 anos e que referiram queixa de IUE. Estas voluntárias foram randomizadas em três grupos: grupos eletroestimulação intravaginal (GEIV, n=15), grupo eletroestimulação de superfície (GES, n=15) e grupo controle (GC, n=15). O GEIV utilizou um eletrodo intravaginal no tratamento e GES realizou a eletroestimulação com quatro eletrodos de silicone fixados bilateralmente cruzados na tuberosidade isquiática e suprapúbica. O GES e GEIV realizaram 12 sessões de tratamento (equipamento Dualpex 961), com o mesmo parâmetro de eletroestimulação e o GC não recebeu qualquer tratamento durante o tempo correspondente. No ESTUDO I as voluntárias de todos os grupos fizeram avaliação antes e após o tratamento, na qual foi realizado o teste do absorvente de uma hora, avaliação da qualidade de vida por meio do King s Health Questionnaire (KHQ) e avaliação da função e pressão dos MAP por meio do perineômetro (Peritron 9300). O ESTUDO II, que incluiu o GES e GC, avaliou a severidade da IUE por meio do teste do absorvente de 1 hora, a atividade elétrica dos MAP por meio da EMG e a qualidade de vida por meio do International Consultation on Incontinence Questionnaire - Short Form (ICIQ-SF). Os resultados do ESTUDO I demonstraram que a EES e a EEIV diminuíram a perda urinária, a pressão de contração dos MAP e a qualidade de vida. No ESTUDO II foi verificado que o tratamento de EES melhorou a atividade elétrica dos MAP. Por meio dos resultados obtidos nestes estudos é possível concluir que a EES e a EEIV apresentam resultados semelhantes e que são duas importantes e efetivas opções de tratamento para a IUE.

Page generated in 0.0953 seconds