Spelling suggestions: "subject:"equipamentos""
201 |
Simulação e otimização de um secador industrial de tunel para frutasCaceres Huambo, Baltazar Nicolas 07 December 2002 (has links)
Orientador: Florencia Cecilia Menegalli / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos / Made available in DSpace on 2018-08-01T22:24:36Z (GMT). No. of bitstreams: 1
CaceresHuambo_BaltazarNicolas_D.pdf: 28723626 bytes, checksum: 03dc6196782a5dd6ded014989951adac (MD5)
Previous issue date: 2002 / Resumo: o objetivo do presente estudo foi desenvolver um modelo matemático para um secador industrial de túnel para fi'utas, simulá-Ia e otimizar sua operação considerando a qualidade do produto como restrição principal na formulação do problema de otimização. Os secadores operam em forma semi-contínua e têm carrinhos e bandejas. O período de cada ciclo é determinado fazendo cumprir as especificações da umidade inicial e final do produto, de forma que cada carrinho com um número determinado de bandejas com fruta úmida seja alimentado em ciclos ao túnel enquanto outro que atingiu a umidade final é retirado do outro extremo do túnel. As configurações consideradas no estudo foram concorrente e contracorrente.
O modelo que foi desenvolvido a partir dos balanços simultâneos de calor e massa para a fase sólida e gasosa, tanto para as bandejas (carrinhos) quanto para o túnel, é simples e apropriado para efeitos de otimização onde o tempo computacional é muito importante. O modelo foi aplicado para simular a secagem de uva Itália usando dados experimentais da cinética de secagem, ajustando-se os parâmetros de acordo aos requerimentos das equações do modelo. Os códigos de simulação e otimização foram
desenvolvidosem FORTRAN 90 de Microsoft Fortran PowerStation.
A não linearidade das equações do modelo e da restrição de qualidade da fruta, representada pela degradação de ácido ascórbico, conduziram ao desenvolvimento de um algoritmo para a solução do problema de otimização cuja função objetivo foi minimizar o consumo de energia por unidade de sólido seco, tempo do ciclo e temperatura máxima atingida pela fruta. Os resultados mostram as condições de operação ótimas para um número fixo de carrinhos no túnel e indicam que a configuração contracorrente é mais eficiente quando se avalia os requerimentos de calor por kg de sólido seco para uma degradação de ácido ascórbico aproximadamente constante. Igualmente, que se reduz o consumo de energia em ambas configurações quando comparado aos valores simulados sem otimizar. / Abstract: The non linearity of the equations of the model and the quality of the fruit, represented by the ascorbic acid degradation, leaded to develop an algorithm for the solution of the optimization problem which objective function was to minimize the energy consumption, cycle time and maximum temperature achieved by the fruit. Results show the optimal operation conditions for a fixed number of trucks in the tunnel and indicate that countercurrent configuration is more efficient when heat requirements per kg of dry solids is evaluated for approximately constant ascorbic acid
degradation. Furthermore, energy consumption for both configurations is reduced when compared to non optimized simulation results. / Doutorado / Doutor em Engenharia de Alimentos
|
202 |
Avaliação de materiais restauradores em cavidades retrogradas preparadas com pontas ultra-sonicasGondim Junior, Eudes 16 October 2002 (has links)
Orientador : Francisco Jose de Souza Filho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-02T19:42:40Z (GMT). No. of bitstreams: 1
GondimJunior_Eudes_D.pdf: 7941631 bytes, checksum: a8b9f4b39b84e33266c5bdd50686a830 (MD5)
Previous issue date: 2002 / Resumo: O objetivo deste estudo foi comparar, usando réplicas de resina epóxica, a topografia de superfícies apicais de caninos humanos contento cavidades retrógradas preparadas com pontas ultra-sônicas antes e depois de seu preenchimento e acabamento com três diferentes técnicas. Também foi realizada uma avaliação quantitativa da capacidade de selamento marginal dessas obturações retrógradas. Oitenta e uma cavidades retrógradas preparadas em caninos humanos foram divididas em grupos de 27 cada. As cavidades foram preenchidas com Super-EBA, IRM, ou ProRoot-MTA e receberam um acabamento inicial com um brunidor de formato arredondado. Dezoito raízes de cada grupo receberam um acabamento final com brocas carbide de tungstênio 30 lâminas (9 raízes) ou com brocas de 28 mm Zekrya (9 raízes). Fotomicrografias de cada espécime obtidas com um microscópio eletrônico de varredura (MEV), antes e depois do preenchimento das cavidades retrógradas, foram comparadas através de um programa de análise de imagens. Após a análise da interface retrobturação/ dentina os espécimes foram preparados e imersos em uma solução de azul de metileno 2% por 12 horas. As raízes foram então trituradas e preparadas para análise em um espectrofotômetro de absorbância. Resultados obtidos mostraram que quando uma broca foi utilizada para um acabamento final nos materiais, uma área significativa (p < 0,05) de ranhuras marginais foi eliminada. A técnica de acabamento não afetou significativamente (p > 0,05) a incidência de fendas nos grupos retrobturados com MT A ou IRM. As obturações retrógradas feitas com Super EBA e IRM, e acabadas com um brunidor ou com brocas Zekrya apresentaram áreas calculadas das fendas significativamente (p < 0,05) maiores que as retrobturações feitas com MT A. Com relação à infiltração os resultados revelaram que o Pro Root MT A apresentou uma média de infiltração significativamente (p < 0,05) menor que retrobturações de Super-EBA e IRM. O fator técnica de acabamento não afetou significativamente (p > 0,05) a incidência de infiltração entre os materiais testados. O coeficiente de correção de Pearson indica que há uma associação positiva de 55,61 % entre as variáveis, ou seja, o acréscimo da quantidade de corante infiltrado está associado com o acréscimo da área de desadaptação das cavidades retrógradas / Abstract: The aim of this study was to compare, using epoxy resin replicas, the surface topography of root ends following ultrasonic preparation, and again after root-end fillings submitted to three different finishing techniques. A quantitatively evaluation of the sealing ability of Super-EBA, IRM and Pro Root MTA root-end fillings was also performed. Eighty-one ultrasonically root-end cavities prepared in human canines, were divided at random into three test groups of 27 each. The cavities were filled with Super-EBA, IRM, or ProRoot-MT A and finished by ball burnishing. Eighteen roots from each group received a final smoothing with either a 30-fluted tungsten carbide finishing bur, or a Zekrya carbide 28 mm bur. Scanning electron micrography (SEM) pictures of each sample were taken prior to and after root-end filling, and dentin/retrofilling interfaces inspected and compared with the aid of an image and analysis system. Samples were then prepared and immersed in 2% methylene blue dye solution for 12 hours. Roots were ground into a powder and prepared for analysis in an absorbency spectrophotometer. Results showed that when a finishing bur was used to finish the set materials, a significant (p < 0.05) area of marginal chipping was eliminated. The fishing technique did not significantly (p > 0.05) affect the incidence of gaps in groups retrofilled with MT A or IRM. Super EBA and IRM retrofillings finished with a ball burnisher or a Zekrya bur displayed a significantly (p < 0.05) larger calculated gap area than roots filled with MT A. In relation to microleakage the results revealed that Pro Root MT A displayed a significantly inferior mean dye microleakage (p < 0.05) than Super-EBA and IRM retrofillings. The finishing technique did not significantly (p > 0.05) affect the incidence of microleakage among the materials tested. The correlation coefficient of Pearson indicates that there is a positive, 55.61% association between the variables and this coefficient, that is, the increase of the quantity of infiltrated dye is associated with the increase of the root-end filling marginal disruption area / Doutorado / Endodontia / Doutor em Clínica Odontológica
|
203 |
Efeitos da interferencia eletromagnetica conduzida em equipamentos eletromedicos no ambiente hospitalarZevzikovas, Marcos 03 August 2018 (has links)
Orientador : Sergio Santos Muhlen / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-03T22:15:42Z (GMT). No. of bitstreams: 1
Zevzikovas_Marcos_M.pdf: 2277931 bytes, checksum: d647f35ad6f338ef8fa869b5cad0b316 (MD5)
Previous issue date: 2004 / Mestrado
|
204 |
Desenvolvimento de um sistema de suspensão hidropneumatica para uso em maquinas agricolasBaldi, Mauricio 20 February 2004 (has links)
Orientador: Pablo Siqueira Meirelles / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-03T22:10:49Z (GMT). No. of bitstreams: 1
Baldi_Mauricio_M.pdf: 5436335 bytes, checksum: c7307a26ee80facbf2c61b034f5c7661 (MD5)
Previous issue date: 2004 / Resumo: Neste trabalho é proposto um modelo de suspensão hidropneumática robusta e com baixo custo para carretas de pulverizadores agrícolas. Este tipo de veículo possui um fator de carga dinâmica elevado que aumenta as cargas nos eixos quando em uso e necessita de um controle de altura para manter a eficiência de pulverização constante. Neste caso, o uso de um sistema de suspensão convencional (rigidez da mola constante), não atende satisfatoriamente aos requisitos do produto. O problema de alterações no coeficiente de amortecimento devido às variações de carga observado em veículos utilizando sistemas de suspensão convencionais é mais acentuado quando utilizam suspensão hidropneumática, devido a sua não linearidade. E este problema é mais acentuado em veículos nos quais a massa possui uma grande variação quando passam da condição vazio para completamente carregado. Este estudo mostra um modelo matemático para a mola hidropneumática e modelos numéricos de 1/4 e 1/2 veículo. Através destes modelos, o comportamento dinâmico entre o veículo utilizando sistema de suspensão convencional e hidropneumático, sob as mesmas condições, é comparado, adotando diferentes critérios para escoJher o valor do amortecimento passivo (valor de amortecimento constante) ou adaptativo (suspensão semi-ativa), este baseado em uma estratégia simples de controle. Testes foram realizados com o uso de um pulverizador agrícola equipado com um sistema de suspensão hidropneumática projetada de acordo com os resultados deste estudo / Abstract: This study proposes a robust and cheap hydropneumatic suspension system for agricultura! trailers used to spread crop protection. This kind of vehic1e has a high dynamic load factor that increases the axles loads when it is in use and require a height control to assure the same spraying efficiency. In this case, the use of conventional suspension system, were the stiffuess is constant, does not achieve product requirements. The well known problem of the damper coefficient changes due to variations in vehic1e's load, using conventional suspension systems, is more perceptible when hydropneumatic springs are used, due to its non-linearity. And this problem is more accentuated in vehicles that presents significantly mass range between empty and full load condition. This study shows a mathematical model of the hydropneumatic spring as well as a numerical model of one quarter and half vehicle. Through these models, a dynamic behavior comparison was performed between the model with conventional springs and using hydropneumatic springs under the same conditions, adopting different criteria to choose the passive (damper value constant) or adaptive damper value (semi-active suspension), the last based on simple control strategy. Experimental tests were performed using an agricultural trailer used to spray crop protection, equipped with a suspension system projected and assembled according with the results of this study / Mestrado / Mecanica dos Sólidos e Projeto Mecanico / Mestre em Engenharia Mecânica
|
205 |
Detecção de lesões cariosas em superficies oclusais : avaliação de diferentes tecnologiasMialhe, Fabio Luiz, 1972- 06 February 2004 (has links)
Orientador: Antonio Carlos Pereira / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T22:58:04Z (GMT). No. of bitstreams: 1
Mialhe_FabioLuiz_D.pdf: 1169041 bytes, checksum: be2b6dab2a979d53b3de227c4686d499 (MD5)
Previous issue date: 2004 / Resumo: O presente trabalho, composto por 3 estudos, teve como objetivo geral avaliar ¿in vitro¿ a eficácia e a reprodutibilidade de diferentes métodos diagnósticos para lesões cariosas em superfícies oclusais. A amostra dos estudos foi composta por 96 molares permanentes. O objetivo do 1º estudo foi comparar o desempenho dos sistemas de radiografia digital CDR (Schick Technologies, EUA) e Sidexis (Sirona, Bensheim, Alemanha) com o método radiográfico convencional, utilizando os resultados do exame histológico como método de validação. Dois examinadores realizaram todos os exames. Concluiu-se, a partir do cálculo da área abaixo da curva ROC para os métodos avaliados, que não houve diferenças estatisticamente significantes entre o desempenho do filme radiográfico convencional em relação aos dois sistemas digitais CCD para a detecção de lesões cariosas em superfície oclusais, porém, houve diferenças entre os dois últimos métodos avaliados. O objetivo do 2º estudo foi comparar o desempenho
de 5 métodos de diagnóstico, ou seja, (1) o exame clínico-visual, (2) o radiográfico convencional, (3) o aparelho QLF (Inspektor Research System BV, Amsterdam, Holanda), (4) o aparelho ECM (LODE, Groningen, Holanda) e, (5) o aparelho DIAGNOdent (Kavo, Biberach, Alemanha) para a detecção de lesões cariosas em supefícies oclusais, comparado ao exame histológico. Os resultados demonstraram que o aparelho DIAGNOdent apresentou valores superiores de sensibilidade, especificifidade, acurácia e área abaixo da curva ROC (Az) em relação aos outros métodos avaliados. Conclui-se, portanto, que este método pode ser um importante adjunto aos exames convencionais nos casos em que há dúvidas quanto a higidez de uma fissura que não apresenta uma imagem radiolúcida ao exame radiográfico. O objetivo do 3º estudo foi comparar o desempenho de quatro métodos de iagnóstico em detectar e estimar a profundidade das lesões cariosas em superfícies oclusais em função dos resultados obtidos a partir de três métodos de validação, ou seja, o exame estereomicroscópio, a microrradiografia transversa e a microscopia confocal de varredura a laser e analisar a correlação entre eles. Concluiu-se, pelos resultados obtidos, que o desempenho dos métodos de diagnóstico não foi influenciado pelos
resultados dos métodos de validação sendo que todos eles podem ser considerados fidedignos para se avaliar o desempenho dos métodos de
diagnóstico avaliados / Abstract: The present thesis, composed by 3 studies, had as general objective to evaluate " in vitro" the efficacy and the reproducibility of different diagnostic methods for carious lesions on occlusal surfaces. The sample of the studies was composed by 96 extracted permanent molars. The objective of the 1st study was to compare the performance of the digital radiographic systems CDR (Schick Technologies, USA) and Sidexis (Sirona, Bensheim, Germany) with the conventional radiographic method for the detection of carious lesions in occlusal surfaces, using the histologic examination as validation method. Two examiners accomplished all the exams. It was concluded, starting from the calculation of the area
below curved ROC for the evaluated methods, that there were not statistically significant differences between the performance of the conventional film and the two CCD digital systems for the detection of carious lesions in occlusal surfaces. However, it was found differences between the two last evaluated methods. The objective of the 2nd study was to compare " in vitro " the performance of 5 diagnostic methods, that is, (1) the clinical-visual
exam, (2) the conventional radiographic examination, (3) the QLF device (Inspektor Research System BV, Amsterdam, Holland), (4) the ECM device (LODE, Groningen, Holland), and (5) the DIAGNOdent device (Kavo, Biberach, Germany) for the detection of carious lesions in occlusal surfaces. The results demonstrated that the DIAGNOdent device presented higher values of sensibility, specificity, accuracy and area below curved ROC (Az) in relation to the other methods. Therefore, it was concluded that this method can be an important adjunct to visual-radiographic examination when there is doubt in relation to the state of fissures. The objective of the 3rd study was to compare the performance of four diagnostic methods to detect and estimated the depth of the carious lesions in function of the results obtained from stereomicroscopy, transversal microradiograph and confocal laser scanning microscopy exams and to analyze the correlation among them. It was concluded, based on the obtained results that the performance of the diagnostic methods was not influenced by the results of thevalidation methods and all they can be considered trustworthy to evaluate the performance of the diagnosis methods / Doutorado / Cariologia / Doutor em Odontologia
|
206 |
Caracterização e quantificação da distribuição do liquido descendente de uma coluna de recheio em escala pilotoKobayasi, Marina Satie 30 November 1998 (has links)
Orientador: Maria Regina Wolf Maciel / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Quimica / Made available in DSpace on 2018-07-25T16:57:58Z (GMT). No. of bitstreams: 1
Kobayasi_MarinaSatie_M.pdf: 5849931 bytes, checksum: e55dcd4abb9ff2b76c083457f38896ae (MD5)
Previous issue date: 1998 / Resumo: A eficiência de vários equipamentos industriais como coluna de destilação de torres de lavagem de gases e colunas de extração, está diretamente relacionada como a homogeneidade da distribuição do liquido no topo destas unidades. Neste trabalho, foi empregado um método simplificado de quantificação da eficiência da distribuição de liquido para caracterizar um coluna de recheio em escala ¿ piloto (diâmetro de 0,4 m e altura de 1,8m), operada com anéis de Pall plásticos de ½ in, utilizando três dispositivos para alimentação do liquido na coluna. Foram definidos dois fatores de eficiência de distribuição ¿ global e de dispersão ¿ a partir de uma superfície normal tridimensional. A eficiência global é derivada da amplitude normalizada da distribuição de líquido e a eficiência de dispersão da variância da distribuição. A distribuição de liquido foi obtida na forma de colunas de liquido em um módulo de coleta localizado na base da coluna e as alturas dessas colunas foram correlacionadas com as suas posições, através de um modlo com 5 parâmetros. As variáveis estudadas foram a vazão de água na alimentação, o ponto de alimentação (centro e duas posições diferentes, equivalentes a distancia radial de 7,5 e 15cm), a altura da seção de recheio, dispositivo distribuidor / Abstract: The efficiency of several industrial equipment as distillation columns, gas cleaning towers and extraction columns, is directly related with the homogeneity of the distribution of the liquid on the top of these units. In this work, a simple method of quantification of liquid distribution efficiency was employed to characterize a packed column (diameter, 0,4 m; height, 1,8m) on a pilot scale operated with 1 in plastic Pall ring, using three distributing device for liquid feeding in the columm. Two distribution efficiency factors ¿ global and dispersion ¿ were defined from a normal tridimensional surface. The global efficiency is derived from the normalized amplitude of the distribution of the liquid, and the dispersion efficiency, from the distribution vaiance. The liquid distribution was obtained in the form of liquid columns in a collecting module located at the base of the column was obtained in the form of liquid columns in a collecting module located at the base of the column and the heights of those columns were correlated its positions, though a model with 5 parameters. The study variables were water flow rate, the feeding point on the upper head of column (center and two different positions, equivalent to the radial distances 7,5 and 15 cm), the height of the random packing section, distributing devices (tube and two models of distributors) and orifice diameter of the distributor / Mestrado / Sistemas de Processos Quimicos / Mestre em Engenharia Química
|
207 |
Estudos dos efeitos do preparo sonico e ultra-sonico de cavidades retrogradas em dentes recem extraidos : analise de replicas com microscopio eletronico de varreduraGondim Junior, Eudes 12 February 1999 (has links)
Orientador: Francisco Jose de Souza Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-25T20:14:41Z (GMT). No. of bitstreams: 1
GondimJunior_Eudes_M.pdf: 15092413 bytes, checksum: 3f9169afbcc9508c7640e8b12602e3e8 (MD5)
Previous issue date: 1999 / Resumo: A nova geração de instrumentos sônicos e ultra sônicos desenvolvidas para o preparo de cavidades retrógradas vem tomando os preparos mais conservadores, profundos e alinhados ao longo eixo do canal radicular. Entretanto, estudos "in vitro" mostram o aparecimento de ranhuras e microfraturas nas superfícies seccionadas submetidas a estes tratamentos. O possível aparecimento de microfraturas em ápices estreitos e frágeis devido a ação vibratória destes sistemas é preocupante. Os objetivos deste estudo foram: avaliar a integridade das superfícies apicaisseccionadas depois da utilização de pontas sônicas e ultra-sônicas para preparos retrógrados; determinar se estruturas radiculares mais finas e pequenas são mais susceptíveis a ação destes instrumentos; comparar quantitativamente a qualidade das cavidades retrógradas. Cinco grupos formados por 16 dente~ anteriores humanos recém extraídos divididos por tipos de dentes e por tamanhos (pequenos e grandes) foram preparados das seguintes formas: tratamento 1- apicectomia e preparo ultra-sônico retrógrado com pontas' KIS; tratamento 2- apicectomia e preparo ultra-sônico retrógrado com as pontas Satelec S-12 (sem diamante); tratamento 3 apicectomia e preparo com o sistema sônico Sonicflex e pontas diamantadas; tratamento 4- apicectomia e preparo ultra-sônico retrógrado com pontas Satelec S-12D (diamantadas). Répiicas das superfícies apicais seccionadas pré e pós-operatórias foram feitas através de moldagens de siloxano. Com o auxílio de um programa de análise de imagens, as imagens das réplicas feitas com um microscópio eletrônico de varredura foram avaliadas com relação às dimensões e a presença de microfraturas ou ranhuras. Os resultados mostraram não haver diferenças estatisticamente significativas em relação à presença de microfraturas ou ranhuras entre os tipos de dente, tratamentos e tamanho das raízes (p>O,05). O tratamento 3 produziu as cavidades menos conservadoras quando comparado aos outros tratamentos, tomando desaconselhável sua utilização em raízes pequenas como as dos incisivos inferiores / Abstract: The new generation of sonic and ultrasonic root-end preparation devices has simplified the rreparation of conservative and sufficiently deep cavities that follow the original path of the root canal. However, "in vitro" studies have demonstrated microfractures and marginal chipping in resected roots after the use of such instruments. The occasional appearance of lines of infraction when vibratory action of sonic and ultrasonic instruments are applied on narrow or more fragile apices raised some concem. The purposes of this study were: to evaluate the integrity of resected root-end surfaces after using sonic and ultrasonic tips for retrograde preparation; to determine if finer and smaller roots are more susceptible to sonic and ultrasonic vibratory action; to compare quantitatively the quality of the root-end cavities. Five groups of 16 freshly extracted hurnan anterior teeth divided by anatomic group and size (small or big) were prepare.d as follows: treatment 1 - root-end resection and root-end cavity preparation with KIS ultrasonic retrotips; treatment 2 - resection and preparation with Satelec S-12 (no I diamond coated) ultrasonic retrotips; treatment 3- resection and preparation with a diamond-coated retrotip driven by a sonic device; treatment 4- resection and preparation with Satelec S-12D (diamond coated) ultrasonic retrotips. The resected pre-operative and postoperative root surfaces were replicated with polyvinylsiloxane impressions. With the aid of image processing and analysis system, the replicas were inspected under a Scanning electron microscope for further evaluation of shape quality and presence of cracks and marginal chipping. The results showed no significant difference in cracking or chipping amongst anatomic groups, treatments and tooth size (p>O.05). Treatment 3 produced less conservative cavities than the other three treatments and should not be used on small teeth as lower incisors / Mestrado / Endodontia / Mestre em Clínica Odontológica
|
208 |
Caracteristicas de usinagem sob o ponto de vista economicoCarvalho, Roberval Rymer da Silva 19 July 1991 (has links)
Orientador: Dino Ferraresi / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-07-14T00:32:55Z (GMT). No. of bitstreams: 1
Carvalho_RobervalRymerdaSilva_D.pdf: 6357219 bytes, checksum: 783039a8d63234a3392dcdb85e986620 (MD5)
Previous issue date: 1991 / Resumo: O presente trabalho fornece as expressões das velocidades de corte de mínimo custo (V ) e de máxima produção (Vmxp), bem como as expressões da vida de mínimo custo (To ) e máxima produção (Tmxp ) de usinagem. Estas expressões foram obtidas com o uso das fórmulas expandida e simplificada de Taylor. Expressões dos tempos e custos de fabricação e de suas derivadas em relação à velocidade de corte (Vc ) para os processos mecânicos de usinagem, obtidas por intermédio de um micro - computador e com o uso de um software - aplicativo são apresentadas ...Observação: O resumo, na íntegra, poderá ser visualizado no texto completo da tese digital / Abstract: In this research-work, expressions for the minimum cost (Vo) and maximum production (Vmxp) cutting speed, as well as minimum cost (To) and maximum production (Tmxp) lifetime, for machining processes are obtained. Expanded and simplified Tatylor formulae are used in the derivation of such expressions...Note: The complete abstract is available with the full electronic digital thesis or dissertations / Doutorado / Doutor em Engenharia Mecânica
|
209 |
Desenvolvimento de um processo d fabricação do copo acetabular de proteses de quadril a partir de moldagem por sinterização do polietileno de ultra alto peso molecularReis, Marcelo de Carvalho, 1965- 20 May 1993 (has links)
Orientador: Alberto Cliquet Jr / O anexo B desta tese não foi digitalizado devido ao seu tamanho, a consula só poderá ser feita através da versão impressa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica / Made available in DSpace on 2018-07-18T10:54:41Z (GMT). No. of bitstreams: 1
Reis_MarcelodeCarvalho_M.pdf: 4634249 bytes, checksum: 68bed9467d76103ff1544a6baee30d67 (MD5)
Previous issue date: 1993 / Resumo: Objetivando o desenvolvimento de um processamento para o Polietileno de Ultra Alto Peso Molecular (PEUAPM) foi projetada, construída e testada a infra-estrutura básica, que possibilite processar o polímero em diferentes condições e ensaiá-Io a desgaste em condições que simulem uma articulação do tipo sinovial. Para o processamento foi construída uma prensa pneumática que possibilita variação das pressões de compactação e um sistema de aquecimento com controle de temperatura. Para os ensaios de desgate foi construído um dispositivo tipo TRI-PIN-ON-DISC. O equipamento permite a realização de ensaios a seco ou em presença de fluido lubrificante, sendo a medida de desgaste efetuada pela perda em peso dos corpos de prova Foi, ainda, realizada a caracterização de polimeros nascentes de duas origens; nacional e alemã. Três aspectos foram estudados:determinação do tamanho médio de partículas, morfologia e topografia das partículas e comportamento térmico / Abstract: Not informed. / Mestrado / Mestre em Engenharia Elétrica
|
210 |
Analise do desempenho de um escarificadorSantos, João Carlos dos 03 May 1994 (has links)
Orientador: Claudio Bianor Sverzut / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agricola / Made available in DSpace on 2018-07-19T13:58:21Z (GMT). No. of bitstreams: 1
Santos_JoaoCarlosdos_M.pdf: 2202259 bytes, checksum: 545fe9ae3cba59e8f5bafe0b4d932e1d (MD5)
Previous issue date: 1994 / Resumo: Este trabalho teve o objetivo de avaliar o desempenho de um escarificador, em função de dois tipos de ponteiras, uma tipo cinzel com ponta dupla(comercial) e outra alada(construída na UNICAMP), e três espaçamentos entre hastes. Foi utilizado um chassi porta ferramenta com 5 hastes escarificadoras, trabalhando à 20 cm de profundidade . Em relação aos fatores ponteira e espaçamento foram avaliados os efeitos dos
parâmetros: velocidade média, força média de tração, resistência específica, potência média, energia média requerida, energia média requerida por volume de solo mobilizado, rugosidade superficial, distribuição de agregados(DMG), empolamento, área da seção mobilizada, área de elevação e incorporação de resíduos vegetais ao solo. O trabalho foi realizado no campo experimental do Centro Pluridisciplinar de Pesquisas Químicas, Biológicas e Agrícolas da Universidade Estadual de Campinas, Campinas - SP. A ponteira alada teve desempenho igual à ponteira tipo cinzel, para os parâmetros: área de elevação, diâmetro médio geométrico, rugosidade superficial, incorporação de resíduos vegetais, empolamento, resistência específica e energia requerida por volume de solo mobilizado~e desempenho inferior para força média, potência média e energia média. Os espaçamentos E2(30,5 cm) e E3(35,5 cm) apresentaram menor resistência 'específica e menor requerimento de energia média por volume de solo mobilizado e ainda a menor incorporação de resíduos vegetais ao solo. Os espaçamentos E2(30,5 cm) e E3(35,5 cm) apresentaram menor esforço de tração e menor requerimento de energia. Não houve interação entre ponteira e espaçamento. De uma maneira geral conclui-se que a ponteira alada pode ser usada no preparo de solo, com vantagens / Abstract: This research was carried out at the Centro Pluridisciplinar de Pesquisas Químicas, Biológicas e Agrícolas(CPQBA) of the Universidade Estadual de Campinas (UNICAMP), Campinas, São Paulo, Brazil. It was studied two types of tips, one chisel type with double point (commercial) and the other one winged (built at UNICAMP) and three different spaciment between rods. It was used a chassis with five scarifier rods. Conceming to
the factors, tip and spacing were avaluated the effects of the parameters: average draft power, specific resistence, potency, energy required, energy required by mobilized soil, volume soil roughness index, aggregate distribution(DMG) and percentage of vegetal covering. The winged tip had the same performance as the chisel type tip for the following parameters: superficial roughness, incorporation of vegetal residue, specific resistence and energy required by volume of soil mobilized. The spacing E3(35,5 cm) and E2(30,5 cm) showed less specific resistence and less energy requirement by volume of soil and yet a greater percentage of soil vegetal covering. It was not found interaction between tip and rod spacing. On the overall, it was concluded that the winged tip can be used for soil prepair with advantages / Mestrado / Maquinas Agricolas / Mestre em Engenharia Agrícola
|
Page generated in 0.0898 seconds