11

Desenvolvimento de um dispositivo capaz de registrar e analisar potenciais evocados auditivos nos domínios do tempo e das freqüências / Development of a device capable of recording and analyzing auditory evoked potentials in the time and frequency domain

Menezes, Pedro de Lemos 02 October 2008 (has links)
A integridade da via auditiva e a investigação do respectivo limiar eletrofisiológico podem ser avaliadas por meio da observação, no domínio do tempo, dos potenciais evocados auditivos de tronco encefálico. Atualmente, nova técnica de análise dos potenciais evocados auditivos, no domínio das freqüências, tem sido utilizada para uma observação particular desses limiares. Assim, com a aplicação da transformada rápida de Fourier, é possível realizar a análise das freqüências comprometidas na audição, de maneira eficiente e rápida. O objetivo com este trabalho, então, foi desenvolver, caracterizar e realizar testes preliminares com um dispositivo único capaz de avaliar os potenciais evocados auditivos nos dois domínios, por meio de uma placa de som, que ainda não havia sido implementada para tal fim. Desse modo, foi produzido um aparelho capaz de registrar sinais biológicos da ordem de 0,5 ?V. Após a caracterização e o estudo simulado, foram conduzidos testes-piloto com doze seres humanos, ouvintes normais (n = 24 orelhas), divididos em dois grupos com o mesmo número de participantes. No grupo 1, os potenciais evocados auditivos de tronco encefálico adquiridos por meio de um instrumento padrão-ouro e de instrumento desenvolvido foram comparados entre si. Em seguida, os achados foram relacionados com o exame no domínio das freqüências formatado no novo aparelho. O grupo 2 foi submetido à avaliação dos potenciais miogênicos vestibulares, também com os dois instrumentos, e suas latências absolutas comparadas. Os resultados demonstraram não haver diferenças significativas entre os dois instrumentos para as amplitudes e latências do potencial evocado auditivo de tronco encefálico. Constatou-se, ainda, que as ondas presentes no domínio do tempo davam respostas equivalentes no domínio das freqüências. Por fim, também não foram encontradas diferenças significativas entre os dois aparelhos para as latências do potencial miogênico vestibular. / The integrity of the auditory pathway and the investigation of the respective electrophysiological threshold can be assessed by observation, in the time domain, of brainstem auditory evoked potentials. This assessment is usually evoked by clicks, which have a wide acoustic spectrum, and consequently serious limitations with respect to frequency specificity, in determining electrophysiological thresholds. New techniques for analyzing auditory evoked potentials in the frequency domain are currently being used for a closer observation of these thresholds. Thus, by applying the fast Fourier transform, one can analyzed the compromised auditory frequencies efficiently and rapidly. This method, on the other hand, does not investigate the integrity of specific auditory pathway structures, as the other method does. Although both types of assessment require similar biological amplifier architecture and are, to a certain extent, complementary, they are performed with two distinct devices. The first, which makes the observation in the time domain, is quite well known and several manufacturers have been producing it for a long time. The second, which inspects the potentials in the frequency domain, was introduced into the market only a few years ago. The aim of this study, therefore, was to develop, characterize and conduct preliminary tests with a single device capable of evaluating the auditory evoked potentials in both domains, by means of a sound card that had not been previously used for this purpose. Thus, a device was produced with biological amplifiers, filters, electrical protection apparatus and a logic control system capable of recording biological signals around 0.5 µV. After characterization and the simulated study, pilot tests were carried out with 12 normal- hearing subjects (n = 24 ears), allocated to two groups of 6 participants. In group 1, we observed the latencies and amplitudes of waves I, III and V of the brainstem auditory evoked potentials, using a gold standard instrument and a developed instrument and later compared them. The findings were then correlated to those of the frequency domain examination formatted on the new device. Group 2 was submitted to an assessment of components p13 and n23 of the vestibular myogenic potentials to observe the most delayed biological signals, also with both instruments, and their absolute latencies were compared. The results showed no significant differences between the two instruments for the amplitudes (p = 0.379; p = 0.301; p = 0.605, waves I, III and V, respectively) and latencies (p = 0.381; p = 0.140; p = 0.255) of the brainstem auditory evoked potentials. It was also found that the waves present in the time domain gave equivalent responses in the frequency domain. Finally, no significant differences were observed between the two devices for the absolute latencies of components p13 and n23 of the vestibular myogenic potentials, with p values of 0.102 and 0.078, respectively. Thus, it was concluded that the new instruments were efficient for the functions tested.
12

Implicações da contribuição endógena e exógena para obtenção do P300 utilizando paradigma de omissão / Implication of endogenous and exogenous contribution to obtain the P300 using the omission paradigm

Sena, Taise Argôlo 16 February 2017 (has links)
Introdução: O P300 é um potencial evocado auditivo que ocorre aproximadamente 300 milissegundos (ms) após a apresentação do estímulo. Geralmente, é evocado ao se utilizar o paradigma tradicional, no qual são apresentados dois estímulos perceptivelmente diferentes: um estímulo frequente (85%) e um estímulo raro (15%). Os indivíduos são orientados a indicar, de alguma maneira, a quantidade de estímulos raros que perceberam durante a realização do exame. O P300 é considerado um potencial endógeno, pois ocorre devido a um evento cognitivo (decisão da ocorrência do estímulo raro). Contudo, alguns estudos mostraram que as características acústicas do estímulo podem interferir no potencial, evidenciando uma contribuição exógena ou sensorial para evocar a resposta. Essas implicações endógenas e exógenas para evocar o P300 ainda não foram totalmente definidas. A avaliação desses aspectos específicos pode ajudar a identificar os geradores desse potencial. Objetivo: verificar o efeito da contribuição endógena e exógena para obtenção do P300, utilizando paradigma tradicional e o paradigma de omissão. Métodos: participaram desse estudo 30 indivíduos jovens adultos, normo-ouvintes sem alteração neurológica ou psiquiátrica aparente. Os indivíduos foram avaliados com o paradigma tradicional (estímulo frequente: 800 Hz; estímulo raro 1200 Hz) e com o paradigma de omissão (estímulo frequente: 800 Hz; estímulo raro: ausência de som). Cada orelha foi avaliada separadamente por ambos os paradigmas na intensidade de 80 dBNPS. Foram apresentados 300 estímulos (45 raros) em cada estimulação. Para a obtenção do P300, foi utilizado o equipamento \"Neuroscan Stim2\" com 12 eletrodos ativos no escalpo, colocados nas seguintes posições: FPz, F4, Fz, F3, C4, Cz, C3, CP6, CP5, P4, Pz e P3. O maior pico após o complexo N1-P2-N2 foi considerado como P300. A amplitude foi medida considerando a linha de base do intervalo pré-estímulo, enquanto a latência foi medida no maior pico positivo. Nesse estudo, foi utilizada a Análise de Variância (ANOVA) com medidas repetidas. Foram realizados mapas topográficos do escalpo para ambas as estimulações. Resultados: para todos os 12 eletrodos analisados nesse estudo, a média da latência em milissegundos foi significantemente menor, e a média da amplitude foi significantemente maior para o paradigma tradicional quando comparado ao paradigma de omissão. Além disso, a morfologia da onda foi mais bem definida para o paradigma tradicional. Os mapas topográficos para ambos os paradigmas mostraram uma ativação mais generalizada e mais positiva na região centro-parietal, indicando que as mesmas áreas foram ativadas em ambos os paradigmas. Conclusão: o presente estudo demonstrou que o estímulo acústico, ausente no paradigma de omissão, influencia a latência, amplitude e morfologia da onda, evidenciando uma contribuição exógena/sensorial para obtenção do potencial / Introduction: The P300 is an auditory evoked potential that occurs approximately 300 ms after the stimulus presentation. It is usually elicited by a traditional paradigm in which two perceptually different stimuli are randomly presented with different proportions - one is frequent (85%) and the other is rare (15%). The tested individual is instructed to somehow indicate the amount of rare stimuli heard. According to the literature, P300 is considered an endogenous potential since it occurs in response to a cognitive event (i.e. decision of the occurrence or not of the rare stimulus). However, few studies have shown that the acoustic characteristics of the stimuli might influence the potential, evidencing some exogenous or sensorial contribution to the response formation. The implications that endogenous and exogenous contributions have to eliciting the P300 are not fully understood yet. The assessment of their specific roles would help to identify the P300 generators. Objective: To verify the effects of the endogenous and exogenous contribution to obtain/elicit the P300 using both the traditional and the omission paradigms. Methods: Thirty normal hearing young adults, without known neurological or psychiatric disorders, participated in this study. The individuals were assessed using P300 elicited by the traditional paradigm (frequent stimulus: 800 Hz; rare stimulus: 1200Hz) and by the omission paradigm (frequent stimulus: 800 Hz; rare stimulus: absence of sound). Both paradigms were presented to one ear at a time, at 80dBSPL, and 300 stimuli (45 rare) were presented in each stimulation. The \"Neuroscan Stim2\" was used to obtain the P300 with 12 active electrodes fixed at the following positions: FPz, F4, Fz, F3, C4, Cz, C3, CP6, CP5, P4, Pz e P3. The largest peak after the N1-P2-N2 complex was considered the P300. Its amplitude was measured considering the pre-stimulation response baseline, while its latency was measured at the most positive peak. The Analysis of Variance (ANOVA) with repeated measures was used in this study. Topographic maps from the scalp to both paradigms were also analyzed. Results: To all 12 electrodes positions analyzed in this study, the mean latency (ms) was significantly earlier and the mean amplitude (?V) was significantly larger for the traditional paradigm compared to the omission paradigm. Also, better wave morphology was obtained for the traditional paradigm. The topographic maps to both paradigms has shown more generalized and positive activation at the centro-parietal region, indicating that the same brain areas were involved in both paradigms. Conclusion: The current study has demonstrated that the acoustic stimulus, absent on the omission paradigm, have an impact on the wave formation in respect to its latency, amplitude and morphology, evidencing the influence of sensorial information to the P300
13

Desenvolvimento de um dispositivo capaz de registrar e analisar potenciais evocados auditivos nos domínios do tempo e das freqüências / Development of a device capable of recording and analyzing auditory evoked potentials in the time and frequency domain

Pedro de Lemos Menezes 02 October 2008 (has links)
A integridade da via auditiva e a investigação do respectivo limiar eletrofisiológico podem ser avaliadas por meio da observação, no domínio do tempo, dos potenciais evocados auditivos de tronco encefálico. Atualmente, nova técnica de análise dos potenciais evocados auditivos, no domínio das freqüências, tem sido utilizada para uma observação particular desses limiares. Assim, com a aplicação da transformada rápida de Fourier, é possível realizar a análise das freqüências comprometidas na audição, de maneira eficiente e rápida. O objetivo com este trabalho, então, foi desenvolver, caracterizar e realizar testes preliminares com um dispositivo único capaz de avaliar os potenciais evocados auditivos nos dois domínios, por meio de uma placa de som, que ainda não havia sido implementada para tal fim. Desse modo, foi produzido um aparelho capaz de registrar sinais biológicos da ordem de 0,5 ?V. Após a caracterização e o estudo simulado, foram conduzidos testes-piloto com doze seres humanos, ouvintes normais (n = 24 orelhas), divididos em dois grupos com o mesmo número de participantes. No grupo 1, os potenciais evocados auditivos de tronco encefálico adquiridos por meio de um instrumento padrão-ouro e de instrumento desenvolvido foram comparados entre si. Em seguida, os achados foram relacionados com o exame no domínio das freqüências formatado no novo aparelho. O grupo 2 foi submetido à avaliação dos potenciais miogênicos vestibulares, também com os dois instrumentos, e suas latências absolutas comparadas. Os resultados demonstraram não haver diferenças significativas entre os dois instrumentos para as amplitudes e latências do potencial evocado auditivo de tronco encefálico. Constatou-se, ainda, que as ondas presentes no domínio do tempo davam respostas equivalentes no domínio das freqüências. Por fim, também não foram encontradas diferenças significativas entre os dois aparelhos para as latências do potencial miogênico vestibular. / The integrity of the auditory pathway and the investigation of the respective electrophysiological threshold can be assessed by observation, in the time domain, of brainstem auditory evoked potentials. This assessment is usually evoked by clicks, which have a wide acoustic spectrum, and consequently serious limitations with respect to frequency specificity, in determining electrophysiological thresholds. New techniques for analyzing auditory evoked potentials in the frequency domain are currently being used for a closer observation of these thresholds. Thus, by applying the fast Fourier transform, one can analyzed the compromised auditory frequencies efficiently and rapidly. This method, on the other hand, does not investigate the integrity of specific auditory pathway structures, as the other method does. Although both types of assessment require similar biological amplifier architecture and are, to a certain extent, complementary, they are performed with two distinct devices. The first, which makes the observation in the time domain, is quite well known and several manufacturers have been producing it for a long time. The second, which inspects the potentials in the frequency domain, was introduced into the market only a few years ago. The aim of this study, therefore, was to develop, characterize and conduct preliminary tests with a single device capable of evaluating the auditory evoked potentials in both domains, by means of a sound card that had not been previously used for this purpose. Thus, a device was produced with biological amplifiers, filters, electrical protection apparatus and a logic control system capable of recording biological signals around 0.5 µV. After characterization and the simulated study, pilot tests were carried out with 12 normal- hearing subjects (n = 24 ears), allocated to two groups of 6 participants. In group 1, we observed the latencies and amplitudes of waves I, III and V of the brainstem auditory evoked potentials, using a gold standard instrument and a developed instrument and later compared them. The findings were then correlated to those of the frequency domain examination formatted on the new device. Group 2 was submitted to an assessment of components p13 and n23 of the vestibular myogenic potentials to observe the most delayed biological signals, also with both instruments, and their absolute latencies were compared. The results showed no significant differences between the two instruments for the amplitudes (p = 0.379; p = 0.301; p = 0.605, waves I, III and V, respectively) and latencies (p = 0.381; p = 0.140; p = 0.255) of the brainstem auditory evoked potentials. It was also found that the waves present in the time domain gave equivalent responses in the frequency domain. Finally, no significant differences were observed between the two devices for the absolute latencies of components p13 and n23 of the vestibular myogenic potentials, with p values of 0.102 and 0.078, respectively. Thus, it was concluded that the new instruments were efficient for the functions tested.
14

Implicações da contribuição endógena e exógena para obtenção do P300 utilizando paradigma de omissão / Implication of endogenous and exogenous contribution to obtain the P300 using the omission paradigm

Taise Argôlo Sena 16 February 2017 (has links)
Introdução: O P300 é um potencial evocado auditivo que ocorre aproximadamente 300 milissegundos (ms) após a apresentação do estímulo. Geralmente, é evocado ao se utilizar o paradigma tradicional, no qual são apresentados dois estímulos perceptivelmente diferentes: um estímulo frequente (85%) e um estímulo raro (15%). Os indivíduos são orientados a indicar, de alguma maneira, a quantidade de estímulos raros que perceberam durante a realização do exame. O P300 é considerado um potencial endógeno, pois ocorre devido a um evento cognitivo (decisão da ocorrência do estímulo raro). Contudo, alguns estudos mostraram que as características acústicas do estímulo podem interferir no potencial, evidenciando uma contribuição exógena ou sensorial para evocar a resposta. Essas implicações endógenas e exógenas para evocar o P300 ainda não foram totalmente definidas. A avaliação desses aspectos específicos pode ajudar a identificar os geradores desse potencial. Objetivo: verificar o efeito da contribuição endógena e exógena para obtenção do P300, utilizando paradigma tradicional e o paradigma de omissão. Métodos: participaram desse estudo 30 indivíduos jovens adultos, normo-ouvintes sem alteração neurológica ou psiquiátrica aparente. Os indivíduos foram avaliados com o paradigma tradicional (estímulo frequente: 800 Hz; estímulo raro 1200 Hz) e com o paradigma de omissão (estímulo frequente: 800 Hz; estímulo raro: ausência de som). Cada orelha foi avaliada separadamente por ambos os paradigmas na intensidade de 80 dBNPS. Foram apresentados 300 estímulos (45 raros) em cada estimulação. Para a obtenção do P300, foi utilizado o equipamento \"Neuroscan Stim2\" com 12 eletrodos ativos no escalpo, colocados nas seguintes posições: FPz, F4, Fz, F3, C4, Cz, C3, CP6, CP5, P4, Pz e P3. O maior pico após o complexo N1-P2-N2 foi considerado como P300. A amplitude foi medida considerando a linha de base do intervalo pré-estímulo, enquanto a latência foi medida no maior pico positivo. Nesse estudo, foi utilizada a Análise de Variância (ANOVA) com medidas repetidas. Foram realizados mapas topográficos do escalpo para ambas as estimulações. Resultados: para todos os 12 eletrodos analisados nesse estudo, a média da latência em milissegundos foi significantemente menor, e a média da amplitude foi significantemente maior para o paradigma tradicional quando comparado ao paradigma de omissão. Além disso, a morfologia da onda foi mais bem definida para o paradigma tradicional. Os mapas topográficos para ambos os paradigmas mostraram uma ativação mais generalizada e mais positiva na região centro-parietal, indicando que as mesmas áreas foram ativadas em ambos os paradigmas. Conclusão: o presente estudo demonstrou que o estímulo acústico, ausente no paradigma de omissão, influencia a latência, amplitude e morfologia da onda, evidenciando uma contribuição exógena/sensorial para obtenção do potencial / Introduction: The P300 is an auditory evoked potential that occurs approximately 300 ms after the stimulus presentation. It is usually elicited by a traditional paradigm in which two perceptually different stimuli are randomly presented with different proportions - one is frequent (85%) and the other is rare (15%). The tested individual is instructed to somehow indicate the amount of rare stimuli heard. According to the literature, P300 is considered an endogenous potential since it occurs in response to a cognitive event (i.e. decision of the occurrence or not of the rare stimulus). However, few studies have shown that the acoustic characteristics of the stimuli might influence the potential, evidencing some exogenous or sensorial contribution to the response formation. The implications that endogenous and exogenous contributions have to eliciting the P300 are not fully understood yet. The assessment of their specific roles would help to identify the P300 generators. Objective: To verify the effects of the endogenous and exogenous contribution to obtain/elicit the P300 using both the traditional and the omission paradigms. Methods: Thirty normal hearing young adults, without known neurological or psychiatric disorders, participated in this study. The individuals were assessed using P300 elicited by the traditional paradigm (frequent stimulus: 800 Hz; rare stimulus: 1200Hz) and by the omission paradigm (frequent stimulus: 800 Hz; rare stimulus: absence of sound). Both paradigms were presented to one ear at a time, at 80dBSPL, and 300 stimuli (45 rare) were presented in each stimulation. The \"Neuroscan Stim2\" was used to obtain the P300 with 12 active electrodes fixed at the following positions: FPz, F4, Fz, F3, C4, Cz, C3, CP6, CP5, P4, Pz e P3. The largest peak after the N1-P2-N2 complex was considered the P300. Its amplitude was measured considering the pre-stimulation response baseline, while its latency was measured at the most positive peak. The Analysis of Variance (ANOVA) with repeated measures was used in this study. Topographic maps from the scalp to both paradigms were also analyzed. Results: To all 12 electrodes positions analyzed in this study, the mean latency (ms) was significantly earlier and the mean amplitude (?V) was significantly larger for the traditional paradigm compared to the omission paradigm. Also, better wave morphology was obtained for the traditional paradigm. The topographic maps to both paradigms has shown more generalized and positive activation at the centro-parietal region, indicating that the same brain areas were involved in both paradigms. Conclusion: The current study has demonstrated that the acoustic stimulus, absent on the omission paradigm, have an impact on the wave formation in respect to its latency, amplitude and morphology, evidencing the influence of sensorial information to the P300
15

Desempenho da linguagem falada de pré-escolares nascidos prematuros e correlatos eletrofisiológicos /

Silva, Isabella Bonamigo da. January 2018 (has links)
Orientadora: Célia Maria Giacheti / Banca: Dionísia Aparecida Cusin Lamônica / Banca: Natália Freitas Rossi / Resumo: A prematuridade é considerada um fator de risco para o desenvolvimento motor, social, cognitivo e de linguagem. Pesquisadores têm utilizado instrumentos nacionais e internacionais para a avaliação da linguagem falada nesta população, destacando a necessidade desta investigação em diferentes aspectos. Uma técnica que tem sido utilizada como ferramenta para a investigação de elementos do processamento da linguagem falada é a eletroencefalografia (EEG) e suas medidas de Event Related Potentials (ERPs). Posto isso, o objetivo deste estudo foi investigar o desempenho da linguagem falada e achados eletrosifiológicos em crianças pré-escolares nascidas prematuras e compará-los aos de crianças nascidas a termo com desenvolvimento típico de linguagem. Para compor o Grupo Amostral I (GAI), participaram 20 crianças nascidas prematuras moderadas de 4 e 5 anos de idade cronológica, e para o Grupo Comparativo I (GCI), 40 crianças nascidas a termo pareadas a seus pares por sexo e idade cronológica. Para esses grupos, foi utilizado o instrumento Preeschool Language Assessment - Second Edition (PLAI-2) para a avaliação da linguagem falada. Como um recorte do GAI, o Grupo Amotral II (GAII) foi composto por oito crianças participantes do GAI, e para o Grupo Comparativo II (GCII), oito crianças participantes do GCI, pareadas ao GAII por gênero e idade cronológica. Para a avaliação eletrofisiológica de GAII e GCII, utilizou-se uma tarefa de julgamento semântico, na qual frases de finais congruente... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Prematurity is considered a risk factor for motor, social, cognitive and language development. Researchers have used national and international instruments for the evaluation of spoken language in this population, highlighting the need for this research in different aspects. One technique that has been used as a tool for the investigation of elements of speech processing is electroencephalography (EEG) and its measures of Event Related Potentials (ERPs). Therefore, the aim of this study was to investigate the performance of spoken language and eletrophysiological findings of preschool children born prematurely and compare to that of full-term children with typical language development. Twenty preterm infants born at the age of 4 and 5 years of age were included in Amostral Group (AGI), and for Comparative Group I (CGI) 40 children born at term were matched to their peers by sex and chronological age. For these groups the Preschool Language Assessment - Second Edition (PLAI-2) instrument was used for the evaluation of spoken language. As a AGI cut, Amotral II Group (AGII) was composed of 8 children participating in the AGI and for Comparative Group II (CGII), 8 children participating in the CGI, matched to AGII by gender and chronological age. For the electrophysiological evaluation of AGII and CGII, a semantic judgment task was used, where congruent and incongruent sentences were presented passively and the electrophysiological records were captured from a 128-channel geodeti... (Complete abstract click electronic access below) / Mestre
16

Estudo cross-over controlado por placebo sobre os efeitos do nitroprussiato de sódio nos potenciais evocados P300 e MMN e na sintomatologia de pacientes com esquizofrenia / Double-blind, placebo-controlled trial of the effects of sodium nitroprusside on P300 and MMN auditory evoked potentials in schizophrenia

Almeida, Juliana Silva de 20 October 2017 (has links)
INTRODUÇÃO: A esquizofrenia é um transtorno que se caracteriza pela desorganização de diversos processos mentais, dentre os quais a cognição. Pacientes com esquizofrenia apresentam alterações na amplitude e latência dos potenciais evocados P300 e MMN. A maioria das drogas antipsicóticas atuais têm pouco efeito sobre os sintomas negativos e prejuízos cognitivos dos pacientes, por isso, pesquisadores têm buscado alternativas farmacológicas que possam agir sobre os prejuízos cognitivos e sintomas negativos. Pesquisas recentes demonstraram que o nitroprussiato de sódio (NPS) é capaz de atenuar algumas das manifestações do transtorno que não respondem adequadamente aos tratamentos hoje disponíveis. OBJETIVO: Investigar os efeitos da infusão de NPS sobre a sintomatologia e os potenciais evocados auditivos MMN e P300 em pacientes com esquizofrenia em um ensaio duplo-cego controlado por placebo. MÉTODO: Foram avaliados 12 pacientes com idade entre 25 e 54 anos em tratamento antipsicótico acompanhados no Hospital das Clínicas da Faculdade de Medicina de Ribeirão Preto. Cada paciente participou de duas sessões experimentais, uma com infusão de NPS e outra com placebo. Escalas psiquiátricas (BPRS e PANSS) foram aplicadas imediatamente antes da infusão de NPS ou soro glicosado, a cada hora durante a infusão e imediatamente após a realização dos exames de P300 e MMN, realizados após o fim da infusão. RESULTADOS: A infusão de NPS foi associada a um aumento significativo da amplitude do potencial evocado MMN e a uma redução nos escores das escalas de sintomas psiquiátricos BPRS e PANSS em comparação com o placebo. CONCLUSÃO: A infusão de NPS foi associada à melhora dos sintomas de esquizofrenia conforme medidos pela BPRS e PANSS e a um aumento da amplitude do potencial evocado MMN. Não houve efeitos da administração do NPS sobre o potencial evocado P300. / INTRODUCTION: Schizophrenia is a mental disorder characterized by disorganization of several mental processes including cognition. Schizophrenia patients present alterations in the amplitude and latency of auditory evoked potentials P300 and MMN. Most current antipsychotics have little or no effect on the negative symptoms or cognitive impairment in schizophrenia, which led researchers to search for pharmacological alternatives that may counteract these manifestations. Recent evidence suggests that sodium nitroprusside (SNP) is able to ameliorate some of the manifestations associated with schizohrenia that do not respond adequately to currently available treatments. OBJECTIVE: To investigate the effects of SNP on schizophrenia symptoms and on the evoked potentials P300 and MMN in a double-blind, placebocontrolled trial. METHODS: The trial involved 12 patients aged 25-54 years in antipsychotic treatment followed up at the Ribeirã Preto Medical School University Hospital. Each patient attended two experimental sessions, one for the infusion of SNP and another for the infusion of placebo. The Brief Psychiatric Rating Scale (BPRS) and the Positive and Negative Syndromes Scale (PANSS) were completed immediately before the infusion, every consecutive hour, and immediately after the P300 and MMN tests, performed after the end of the infusion. RESULTS: The infusion of SNP was associated with a significant increase in the amplitude of MMN and with a reduction in the psychopathology scores of the BPRS and PANSS compared to placebo. CONCLUSION: The administration of SNP was associated with an improvement in schizophrenia symptoms as measured with the BPRS and PANSS and with an increase in the amplitude of the evoked potential MMN. There were no effects of SNP on the evoled potential P300.
17

Tratamento e análise de sinais neurológicos visuais com wavelets / Treatment and analysis of visual neurological signals with wavelets

Weiderpass, Heinar Augusto 30 September 2008 (has links)
O potencial visual evocado (PVE) é um sinal elétrico de baixa intensidade originado no córtex visual em resposta a uma estimulação visual periódica. O potencial visual evocado de varredura é um procedimento de PVE modificado para medir acuidade visual de grades em pacientes pré-verbais e não-verbais. Este biopotencial está imerso em uma grande quantidade de ruído eletroencefalográfico e artefato relacionado ao movimento. A relação sinal-ruído tem um papel dominante na determinação de erros sistemáticos e estatísticos. O propósito deste estudo é apresentar um método baseado na transformada wavelet para filtrar e extrair o potencial evocado visual de varredura. Grades de luminância de onda senoidal moduladas em 6 Hertz foram usadas como estímulo para se determinar os limiares de acuidade. A amplitude e a fase da 2ª. harmônica (12 Hertz) do padrão de resposta foram analisadas usando-se a transformada rápida de Fourier após a filtragem por wavelet. O método da transformada wavelet discreta foi usado para decompor o PVE em coeficientes wavelet, determinando-se quais destes representavam uma atividade significativa. Em um passo seguinte somente os coeficientes relevantes foram considerados, zerando-se os demais e reconstruindo-se, assim, o sinal PVE. Isto resultou na filtragem das demais freqüências que foram consideradas ruído. Simulações numéricas e análises com dados de PVE humanos mostraram que este método forneceu maior relação sinal-ruído quando comparado com o método clássico dos mínimos quadrados recursivo (RLS) e ainda uma análise de fase mais apropriada / Visually evoked potential (VEP) is a very small electrical signal originated in the visual cortex in response to periodic visual stimulation. Sweep-VEP is a modified VEP procedure used to measure grating visual acuity in non-verbal and preverbal patients. This biopotential is buried in a large amount of electroencephalographic noise and movement related artifact. The signal-to-noise ratio (SNR) plays a dominant role in determining both systematic and statistic errors. The purpose of this study is to present a method based on wavelet transform technique for filtering and extracting steady-state sweep-VEP. Counter-phase sine-wave luminance gratings modulated at 6 Hertz were used as stimuli to determine sweep-VEP grating acuity thresholds. The amplitude and phase of the second-harmonic (12 Hertz) pattern reversal response were analyzed using the fast Fourier transform after the wavelet filtering. The wavelet transform method was used to decompose the VEP signal into wavelet coefficients by a discrete wavelet analysis to determine which coefficients yield significant activity at the corresponding frequency. In a subsequent step only significant coefficients were considered and the remaining was set to zero allowing a reconstruction of the VEP signal. This procedure resulted in filtering out other frequencies that were considered noise. Numerical simulations and analyses of human VEP data showed that this method has provided higher SNR when compared with the classical recursive least squares (RLS) method. An additional advantage was a more appropriate phase analysis showing more realistic second-harmonic amplitude value during phase brake
18

Potencial visual evocado por flashes de luz em cães diabéticos com catarata / Flash visual evoked potential in diabetic dogs with cataract

Lustoza, Adriana Cabral 16 December 2008 (has links)
Os cães têm apresentado uma maior prevalência de DM nos últimos anos, sendo uma das endocrinopatias mais comuns. As complicações a curto e longo prazo incluem alterações retinianas, renais e neurológicas. Dentre as alterações mais evidentes podemos citar o desenvolvimento de cataratas e alterações nas vias visuais. As alterações das vias visuais são detectadas precocemente por testes eletrofisiológicos, métodos objetivos que independem da informação do paciente e necessitam de pouca colaboração para serem executados. Neste estudo utilizamos o PVE-F, que consiste em potenciais de baixa amplitude registrados quando a retina é submetida à estimulação visual adequada em uma cúpula de campo total, e avalia a integridade das vias ópticas desde a retina até o córtex occipital. Com este estudo objetivamos avaliar as alterações das vias visuais do PVE-F em cães diabéticos portadores de catarata, consoante os critérios da ISCEV. Para o projeto foram utilizados 59 cães, selecionados quanto aos melhores registros e com menor interferência, com idade variando entre 5 e 14 anos, de pequeno à médio porte (até 20kg) de diferentes raças, 46 fêmeas e 13 machos, encaminhados ao Serviço de Oftalmologia do Hospital Veterinário da Faculdade de Medicina Veterinária e Zootecnia da Universidade de São Paulo. Os animais foram divididos em 3 grupos: grupo normal (GN) cães adultos hígidos; grupo catarata (GC) cães apresentando catarata madura ou hipermadura; grupo diabético (GD) cães apresentando catarata madura ou hipermadura, com diabetes mellitus. Todos os grupos foram analisados quanto à latência (ms) e quanto à amplitude (V). O registro do PVE foi obtido por eletrodos de contato superficial utilizando o Sistema Eletrodiagnóstico Computadorizado Veris 2000 com frequência de 2Hz totalizando 180 estímulos. Os animais permaneceram com a cabeça introduzida no interior da cúpula geradora dos flashes de luz branca (Ganzfeld) durante todo o exame. Os potenciais foram registrados em ambos os olhos, no olho direito (ocluindo olho esquerdo) e posteriormente no olho esquerdo (ocluindo olho direito). Em relação ao pico P2 houve semelhança entre os olhos examinados, porém os valores das médias do GD foram maiores que os demais, com significância estatística ao GN (p=0,001) e ao GC (p=0,000). O GD apresentou valores de médias: AO 97,72ms; OD 98,10ms e OE 97,21ms. O GC apresentou valores de médias: AO 86,73ms; OD 86,27ms e OE 86,87ms. O GN apresentou valores de médias: AO 73,20ms; OD 74,53ms e OE 74,33ms. A amplitude (µV) dos intervalos N1-P1, P1-N2 e P2-N2 mostrou semelhança entre os grupos estudados (GN, GC e GD). Porém, os intervalos P1-N2 e N2-P2 apresentaram diferenças entre os olhos, com valores de médias de AO maiores em relação ao OD e OE estatísticamente significantes (p=0,000). No estudo realizado, os valores de glicemia estavam maiores no GD, com uma média de 202,79 mg/dl, enquanto que o GN apresentou média de 78,47 mg/dl e o GC 74,80 mg/dl. Conclui-se que as alterações nas vias visuais estão presentes nos cães diabéticos independentemente do tempo de DM, idade e controle glicêmico, e o PVE-F é um teste útil e importante capaz de detectar estas alterações. / Dogs have been frequently affected by Diabetes mellitus; nowadays, one of the commonest endocrinopathy in this specie. It causes short and long term complications in different organs, such as eyes, kidneys and nervous system. The most evident complication seen in DM dogs is the diabetic cataract and the alterations of the visual pathway. Most of the visual pathway alterations are early diagnosed by electrophysiological tests, objective methods which doesn´t need patient information and requires minimal co-operation to be performed. The aim of this study was to evaluate the integrity of the optic pathway, from the retina to the occipital cortex, in diabetic dogs with cataracts using the PVE-F test and the ISCEV standards. PVE-F is an electrophysiological test based on the registration of low amplitude potentials urged from the retina when stimulated by full field dome. The exam was performed at the Ophthalmology Service, of the Veterinary Hospital of the Veterinary College University of São Paulo in fifty-nine animals, including 46 female and 13 male dogs, with ages varying from 5 to 14 years and weighting less than 20kg. Dogs were divided in 3 groups: healthy dogs without ocular alterations (GN); healthy dogs with mature or hyper mature cataract (GC); diabetic dogs presenting mature or hyper mature cataract (GD). PVE-F was realized using Veris 2000 Computerized Electrodiagnostic System, adjusted for 2Hz flashes (180 flashes) while dogs, with superficial contact electrodes, were kept with their heads inside the generator dome of white light flashes (Ganzfeld). Registers were obtained from both eyes - AO; right eye - OD (occluding left eye) and left eye - OE (occluding right eye) and those with less interference were chosen. Latencies (ms) and amplitudes (V) in each group were analyzed separately. Similarity at peak P2 was observed in every examined eye, but mean values on GD were higher when compared to other groups, with statistically significance on GN (p=0,001) and GC (p=0,000) as shown: (GD): AO 97,72ms, OD 98,10ms and OE 97,21ms; (GC): AO 86,73ms, OD 86,27ms and OE 86,87ms; (GN) AO 73,20ms, OD 74,53ms and OE 74,33ms. Similarity at amplitude (µV) intervals N1-P1, P1-N2 and P2-N2 was observed in every studied group (GN, GC and GD). On the other hand, difference in P1-N2 and N2-P2 intervals registers were observed when comparing eyes: both eyes mean values were higher than OD and OE values, with statistically significance (p=0,000). Glycemic values were higher in GD, with mean values of 202,79 mg/dl, whereas GN was 78,47 mg/dl and GC 74,80 mg/dl. These study demonstrates that diabetic dogs presents alterations at the visual pathway function, independent of the DM time, age and glycemic control and that PVE-F is an important and useful test able to detect such alterations.
19

Registro do PEATE-FE com estímulo NB CE-chirp® LS utilizando o transdutor ósseo B-71 em crianças ouvintes e com perda auditiva condutiva / Record of AEP-FS with NB CE-chirp LS stimulus using the B-71 bone transducer in children with normal hearing and conductive hearing loss

Freitas, Warlesson Gonçalves de 14 May 2018 (has links)
Submitted by Filipe dos Santos (fsantos@pucsp.br) on 2018-07-23T12:51:16Z No. of bitstreams: 1 Warlesson Gonçalves de Freitas.pdf: 1207070 bytes, checksum: eb05ef298b74e3a073b7ef9bd8246f40 (MD5) / Made available in DSpace on 2018-07-23T12:51:16Z (GMT). No. of bitstreams: 1 Warlesson Gonçalves de Freitas.pdf: 1207070 bytes, checksum: eb05ef298b74e3a073b7ef9bd8246f40 (MD5) Previous issue date: 2018-05-14 / Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPq / Introduction: In the last two decades researchers have concentrated on the construction of a new type of broadband stimulus and a narrowband version for the realization of the AEP-FS. Such studies are attempts to improve the amplitude as well as to reduce the time necessary to record the Potential Auditory Evoked test called chirp. Objective: To describe the latency, amplitude and minimum levels of response in the Bone-Conducted Brainstem Auditory Evoked Potentials recording, with the B-71 transducer in hearing children and with conductive hearing loss using the NB CE-Chirp® LS stimulus in the frequencies of 500 and 2000 Hz. Method: 14 children (22 ears) average age of 3.5 months were evaluated. The AEP-FS was recorded in the intensities of 10 to 50 dB nNA (maximum output of the equipment), always seeking the minimum level of each child response. The Radioear B-71 bone transducer was used with the manual method of fixation performed by a second experienced researcher. The latency averages in the two ears as well as the latency averages with the NB CE-Chirp® LS and Toneburst stimuli were compared by means of the Student t-test. Results: Bone conducted AEP-FS using the NB CE-Chirp® LS stimulus in the frequencies of 500 and 2000 Hz presented lower mean V-wave latencies and higher wavelength when compared to results obtained with the toneburst stimulus described in literature, mainly in the frequency of 500 Hz. No significant difference was observed in the latency and amplitude variables between the right and left ears. Conclusion: NB CE-Chirp® LS stimulation was promising in its use in the bone conducted AEP-FS. However, research with a larger number of subjects should be carried out in order to introduce normative values for its clinical usage / Introdução: nas duas últimas décadas, grupos de pesquisadores concentraram-se na construção de um novo tipo de estímulo de banda larga e de uma versão de banda estreita para a realização do PEATE, na tentativa de alcançar maiores amplitudes e de reduzir o tempo de teste necessário para o registro Potencial Evocado Auditivo, estímulo este, denominado chirp. Objetivo: descrever e comparar os resultados de latência, amplitude e níveis mínimos de resposta no registro do PEATE por via óssea em crianças ouvintes e com perda auditiva condutiva, utilizando o estímulo NB CE-chirp® LS nas frequências de 500 e 2000 Hz. Método: foram avaliadas 14 crianças (22 orelhas), com idade média de 3,5 meses nas frequências de 500 e 2000 Hz. O PEATE-FE foi registrado nas intensidades de 10 a 50 dB nNA (saída máxima do equipamento), buscando sempre o nível mínimo de resposta da criança. Foi utilizado o transdutor ósseo Radioear B-71, utilizando o método manual de fixação realizada por um segundo pesquisador experiente. As médias das latências nas duas orelhas e as médias da latência com os estímulos NB CE-chirp® LS e tone burst foram comparadas por meio do teste t-Student. Resultados: O PEATE-FE, por via óssea utilizando o estímulo NB CEchirp ® LS nas frequências de 500 e 2000 Hz, apresentou latências médias de onda V menores e amplitude de onda maior, quando comparado com resultados obtidos com o estímulo tone burst descrito na literatura, principalmente na frequência de 500 Hz. Não foi observada diferença significativa nas variáveis latência e amplitude entre as orelhas direita e esquerda. Conclusão: o estímulo NB CE-chirp® LS mostrou-se promissor em sua utilização no PEATE-FE por via óssea, porém, novas pesquisas com maior número de sujeitos, devem ser realizadas com o objetivo de lançar valores de normatização para seu uso clínico
20

Influência da desnutrição na função auditiva de crianças desnutridas do sul do Maranhão, Brasil / Influence of malnutrition in auditory function of malnourished children in southem Maranhão, Brazil

Penido, Rosimar Costa 25 May 2015 (has links)
A desnutrição proteico-calórica é um dos maiores problemas de saúde pública no Brasil, especialmente no Nordeste, acometendo, com maior frequência, crianças pré-escolares e determinando possíveis comprometimentos, não só no crescimento ponderal como intelectual e cognitivo, podendo ocasionar déficits irreversíveis, dependendo da sua intensidade e duração. Considerando-se a importância da integridade anatomofisiológica do sistema auditivo periférico e central para o adequado desenvolvimento da plenitude das habilidades auditivas, de linguagem e aquisição de aprendizagem, torna-se fundamental a reflexão sobre os possíveis efeitos deletérios da desnutrição no sistema nervoso auditivo, para que possíveis anormalidades auditivas sejam identificadas e tratadas nessa população. O objetivo deste estudo foi caracterizar as respostas do Potencial Evocado Auditivo de Tronco Encefálico, com estímulos clique e tone burst, em crianças de zero a 60 meses, desnutridas e eutróficas, com função auditiva periférica íntegra, bem como compará-las. Foram examinadas 111 crianças de zero a 60 meses, sendo 57 desnutridas e 54 normonutridas, com avaliação otorrinolaringológica, imitanciometria e Emissões Otoacústicas Evocadas Transientes dentro dos padrões de normalidade. A seguir, os Potenciais Evocados Auditivos do Tronco Encefálico por estímulo clique e tone burst foram registrados. Na análise dos dados, observou-se que as latências das ondas I, III e V e dos interpicos III-V a 80 dBNA com estímulo clique eram significativamente maiores em crianças desnutridas, quando comparadas às eutróficas, assim como do intervalo I-V na faixa etária de 0-24 meses. As latências da onda V nas intensidades de 60, 40 e 30 dBNA também foram significativamente maiores em crianças desnutridas. Na análise do Potencial Evocado Auditivo de Tronco Encefálico tone burst, a onda V mostrou latência maior nas crianças desnutridas em todas as intensidades e frequências testadas, entretanto, essa diferença nas crianças de zero a 24 meses só foi significativa em 2000 Hz; nas de 25 a 60 meses foi significativa apenas em 500 Hz a 80 dBNA, em 2000 Hz a 30 dBNA e em 4000 Hz a 60, 40 e 30 dBNA. Crianças desnutridas apresentaram alterações no Potencial Evocado Auditivo do Tronco Encefálico, caracterizadas pelo atraso na latência das ondas e dos intervalos interpicos, quando comparadas às eutróficas, sugerindo déficit de condução na via auditiva. Sendo assim, concluiu-se que a desnutrição pode provocar efeitos deletérios no processo de desenvolvimento e maturação do sistema nervoso auditivo. / Introduction: protein calorie malnutrition is one of the biggest public health problems in Brazil, especially in the northeast, affecting most often preschool children and determining possible compromises not only the weight growth but also intellectual and cognitive development, which may cause irreversible deficit, depending on its intensity and duration. Considering the importance of anatomical and physiological integrity of the peripheral and central auditory system for the proper development of the fullness of auditory skills, language, and acquisition of learning, this brings out a fundamental reflection over the possible deleterious effects of malnutrition in the auditory nervous system, so that possible auditory abnormalities are identified and addressed in this population. The objective of this study was to characterize the response of the auditory brainstem evoked potentials test with click and tone burst stimuli in malnourished and eutrophic children from 0 to 60 months of age, with normal peripheral auditory function, as well as to compare them. Casuistic and Method: One hundred and eleven children from 0 to 60 months of age were examined, being 57 malnourished and 54 eutrophic. They underwent ENT evaluation, including impedanciometry and transient evoked otoacoustic emission (TEOAE) being those within normal ranges. Folowing, the auditory brainstem evoked potentials with click and tone burst were registered in the intensity of 80, 60, 40 and 30 dBNA. Results: In the analysis of the results, the latencies of waves I, III and V and the interpeak III-V 80 dBNA latencies with click stimuli were significantly higher in all malnourished children, when compared to the eutrophic children, as well as I-V interpeak interval in the 0-24 months of age group. The wave V in 60, 40 and 30 dBNA latencies were also significantly higher in malnourished children. In the analysis of the tone burst auditory brainstem evoked potentials wave V latency showed higher in malnourished children in all intensities and frequencies tested, however this difference in children from 0-24 months were significant only in 2000 Hz; in children from 25-60 months were significant only at 500 Hz to 80 dBHL, in 2000 Hz at 30 dBHL and 4000 Hz to 60, 40, and 30 dBHL.Malnourished children present a higher range of alterations in auditory brainstem evoked potentials, characterized by delayed wave latencies and higher interpeak intervals when compared with eutrophic children, suggesting a peripheral and central deficit in the auditory pathway, thus concluded that malnutrition may cause deleterious effects in the development and maturation of the auditory nervous system.