• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 9
  • 8
  • 6
  • 6
  • 6
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Rangi za Kiswahili

Schadeberg, Thilo C. 15 October 2012 (has links) (PDF)
Swahili has a larger inventory of (more or less \"basic\") colour terms than most Bantu languages. The aim of this article is to present this colour terminology and to point out semantic, syntactic and morphological divergences. We also look at the etymology of the various colour terms and try to establish a chronology of the growth (and decline?) of Swahili colour terminology.
2

La dénomination des couleurs chez les Beri du Tchad

Khidir, Zakaria Fadoul 25 March 2019 (has links)
Les Вεrι ne semblent pas connaître un terme générique pour designer les couleurs : ils font usage d’un emprunt à l´arabe [lo:n]. Mais ils utilisent par contre six séries de couleurs dont chacune constitue un domaine de conception, spécifique par rapport aux autres, bien que souvent on manque des termes pour désigner chaque couleur par un seul et même nom. Chacune des séries apparaît assez diversifiée par la variété des notions qu´elle exprime. Les couleurs, dans le système de Вεrι.
3

Rangi za Kiswahili

Schadeberg, Thilo C. 15 October 2012 (has links)
Swahili has a larger inventory of (more or less \"basic\") colour terms than most Bantu languages. The aim of this article is to present this colour terminology and to point out semantic, syntactic and morphological divergences. We also look at the etymology of the various colour terms and try to establish a chronology of the growth (and decline?) of Swahili colour terminology.
4

Überprüfung der Wirksamkeit von blauen, akustischen und multi-farbenen Reflektoren zur Bekämpfung von Wildunfällen auf Landstraßen: Forschungsbericht

Gesamtverband der Deutschen Versicherungswirtschaft e. V. 29 April 2021 (has links)
Verglichen mit dem Gesamtunfallgeschehen auf deutschen Straßen stellen Wildunfälle nur ein relativ geringes Verletzungsrisiko für Verkehrsteilnehmer dar. Wildunfälle geschehen fast ausschließlich auf Außerortsstraßen. 2017 wurden dort 2.334 Wildunfälle mit Personenschaden polizeilich erfasst, das entspricht rund 2,5 Prozent aller Unfälle mit Personenschaden im Außerortsbereich. Dabei wurden 10 Personen getötet, 561 schwer und 2.121 leicht verletzt. Etwa 96 Prozent dieser Unfälle ereigneten sich auf Landstraßen, also außerhalb des Autobahnnetzes. Wildunfälle sind überwiegend Unfälle mit Sachschaden, die oft nicht polizeilich aufgenommen werden. Es gibt daher eine sehr hohe Dunkelziffer in der amtlichen Statistik. Die Anzahl der bei den Kfz-Kaskoversicherern gemeldeten Schadensfälle infolge von Wildunfällen hat sich in den letzten zehn Jahren um 14 Prozent auf rund 275.000 im Jahr 2017 erhöht; die damit verbundenen Versicherungsleistungen stiegen im selben Zeitraum sogar um rund 50 Prozent auf 744 Millionen Euro (Abbildung 1). Das heißt, der Kostenanstieg der Versicherungsleistungen beträgt das Dreieinhalb-fache des Anstiegs der Wildunfälle im betrachteten Zeitraum. Wildschäden belegen bei den PKW-Schadensfällen in der Kaskoversicherung nach dem Glasbruch den zweiten Rang. Wildschäden an Fahrzeugen ohne Kaskoversicherung werden in der Regel nicht erfasst und sind damit Teil der Dunkelziffer. Nach der Wildunfallstatistik des Deutschen Jagdverbandes werden je nach Wildart bis zu 20 Prozent der Wildtiere nicht durch die Jagd erlegt. Die meisten davon werden vermutlich durch Kollisionen mit Fahrzeugen im Straßenverkehr getötet. Aufgrund des zunehmenden Verkehrs ist anzunehmen, dass diese Anzahl in den kommenden Jahren weiter steigen wird (Bruinderick und Hazebroek 1996, Seiler 2004, Gritzka et al. 2010). Die in den vergangenen Jahren eingesetzten Gegenmaßnahmen sind in der Regel sehr kostenintensiv (z.B. Wildzäune und Wildbrücken) oder hatten wenig Erfolg (z.B. weiße und rote Reflektoren, Wildwechselzeichen; vgl. Bruinderick und Hazebroek 1996). In einer von der Unfallforschung der Versicherer (UDV) bereits 2007 publizierten Untersuchung zur Wirksamkeit von weißen, roten und akustischen Reflektoren konnte keine Wirkung auf die Zahl der Unfälle mit Wildbeteiligung nachgewiesen werden (Voß et al. 2007). Nach der Veröffentlichung dieser Studie mehrten Berichte dass blaue Reflektoren zu einer Verminderung von Wildunfällen führen würden. Allerdings haben die Hersteller dieser Reflektoren bis heute keine breit angelegte wissenschaftliche Studie vorgelegt, die eine statistisch signifikante Reduzierung von Wildunfällen durch ihre Produkte nachweist. Vor diesem Hintergrund hat die UDV die hier vorliegende neue Studie initiiert und finanziert, die durch die Georg-August-Universität Göttingen in Kooperation mit der Universität Zürich durchgeführt wurde. Die zu klärende zentrale Frage war, ob das Anbringen von blauen oder multi-farbigen Reflektoren die Anzahl der Wildunfälle dauerhaft wirksam reduzieren kann. Zudem sollte geklärt werden, inwieweit infrastrukturelle, straßenraumgestalterische, landnutzungs- oder tierspezifische Merkmale einen maßgebenden Einfluss auf das Wildunfallgeschehen haben können.
5

In Vitro and In Vivo Applications of Fluorescence Cross-Correlation Spectroscopy / In vitro und in vivo Anwendungen der Fluoreszenz-Kreuzkorrelations-Spektroskopie

Staroske, Wolfgang 18 November 2010 (has links) (PDF)
Fluorescence correlation spectroscopy (FCS) analyzes the fluctuations in the fluorescence intensity, which is emitted from a tiny excition volume, to obtain information about the concentration, the mobility, and the molecular interactions of labeled molecules. The more advanced fluorescence cross-correlation spectroscopy (FCCS) increases the precision in the determination of fl ow velocities and binding constants compared to standard FCS. The miniaturization in biomedical and chemical engineering has been developing rapidly, propelled by the vision of a fully functional laboratory on a single chip and its use in human therapeutics, for example, as implanted drug delivery system. A key requirement to fulfill this vision is the ability to handle small fl uid volumes. Handling liquids using the electrohydrodynamical principle circumvents many of the disadvantages of other systems. The complex flow pattern in the active region of such a pump could not be resolved by common tracking techniques. In this thesis, two-focus FCCS (2f-FCCS) was used to map the flow pro file inside a micropump. The high precision of 2f-FCCS in the determination of fl ow measurements even with small fluorescent particles allowed the measurement of the flow velocities induced by electrohydrodynamic forces acting on the solvent, while excluding the effects of dielectrophoretic forces acting on larger particles. Analysis of the fl ow data indicates a fl ow pattern that consists of two vortices of different size and opposite direction of rotation. The flow pattern derived by 2f-FCCS explains the observed complex particle trajectories in the force field and the accumulation of particles in well-de fined regions above the microelectrode array. In the second part of this thesis, the mechanism of RNA interference (RNAi) was studied by dual-color FCCS in vivo. RNAi is an evolutionary conserved gene silencing mechanism, which uses short double-stranded RNA molecules, called short interfering RNAs (siRNAs), as effector molecules. Due to its speci city and simplicity, RNAi yields a great potential for a widespread therapeutic use. To broaden the therapeutic applications, the in vivo stability of siRNAs has to be improved by chemical modi cations, but some of these modi fications inhibit the gene silencing mechanism. The presented FCCS assays are very well suited to investigate the individual assembly steps of RNAi machinery with very high specifi city and sensitivity in real time and to study the cleavage activity of the activated RNAi machinery. A direct correlation between activity of the RNAi machinery and the results from the FCCS measurements could be shown. The in fluence of several chemical modi cations on the assembly and activity of the RNAi machinery was investigated with these assays. / Fluoreszenz-Korrelations-Spektroskopie (FCS) analysiert die Fluktuationen im Fluoreszenzsignal eines kleinen angeregten Volumens, um Informationen über die Konzentration, die Bewegung und die Interaktionen der markierten Moleküle zu erhalten. Die Fluoreszenz-Kreuzkorrelations-Spektroskopie (FCCS) erhöht die Genauigkeit bei der Messung von Fließgeschwindigkeiten und Bindungskonstanten im Vergleich zur Standard-FCS. Die Miniaturisierung der Biomedizin und Chemie hat sich rapide entwickelt, angetrieben von der Vision eines kompletten Labors auf einem Chip und dem Einsatz dieses in der medizinischen Therapie, zum Beispiel als implantierter Medikamentenspender. Ein Schlüsselelement zur Erfüllung dieser Vision ist der Transport von kleinsten Flüssigkeitsmengen in diesen miniaturisierten Systemen. Der Transport von Flüssigkeiten mittels des elektrohydrodynamischen Prinzips umgeht viele Nachteile von anderen Systemen, allerdings zeigt eine solche Pumpe ein kompliziertes Strömungsbild in der aktiven Region, welches sich mit herkömmlichen Methoden wie Teilchenverfolgung nicht vermessen ließ. Hier wurde Zwei-Fokus-FCCS (2f-FCCS) genutzt, um das Strömungsbild in der Pumpe zu vermessen. Die hohe Genauigkeit der 2f-FCCS bei der Bestimmung von Fließgeschwindigkeiten auch mit kleinen fluoreszierenden Teilchen ermöglichte die Messung der Fließgeschwindigkeiten, aufgrund der auf das Lösungsmittel wirkenden elektrohydrodynamischen Kräfte, unter Ausschluss der auf größere Teilchen wirkenden dielektrophoretischen Kräfte. Die Analyse der Daten ergab, dass das Strömungsbild aus zwei entgegengesetzt rotierenden unterschiedlich großen Wirbeln besteht. Dieses Strömungsbild erklärt die komplizierten Teilchenbewegungsbahnen und die Anreicherung der Teilchen in klar abgegrenzten Bereichen über den Mikroelektroden. Im zweiten Teil dieser Arbeit wurde der RNAi-Mechanismus in lebenden Zellen mittels Zwei-Farben-FCCS untersucht. RNA Interferenz (RNAi) ist ein evolutionär erhaltener Geninaktivierungsmechanismus, der kurze doppelsträngige RNA Moleküle, so genannte kurze interferierende RNAs (siRNAs), als Effektormoleküle nutzt. Die Spezifi tät und Einfachheit der RNAi hat ihr ein weites Feld in der medikamentösen Therapie geöffnet. Zur Erweiterung dieses Feldes ist es nötig die Stabilität der siRNAs im Körper mittels chemischer Modi fikationen zu erhöhen. Einige dieser Modifikationen hemmen aber den RNAi-Mechanismus. Die hier vorgestellten FCCS Experimente sind sehr gut geeignet, um die einzelnen Schritte des Zusammenbaus der RNAi Maschinerie mit hoher Empfi ndlichkeit und Spezi fität in Echtzeit zu untersuchen und die Aktivität der RNAi Maschinerie zu studieren. Es konnte ein Zusammenhang zwischen der Aktivität der RNAi Maschinerie und den Ergebnissen der FCCS Messungen hergestellt werden. Der Einfluss von verschiedenen chemischen Modikationen auf den Zusammenbau und die Aktivität der RNAi Maschinerie wurde mit diesen neuartigen Methoden untersucht.
6

Farbe als Herausforderung im Textilrecycling

Tomovic, Tina 30 June 2022 (has links)
Der Textilindustrie wird hinsichtlich umweltschädlicher Emissionen ein schlechtes Zeugnis ausgestellt. Bisweilen nimmt sie sogar einen unrühmlichen zweiten Platz ein und hat damit unweigerlich eine grosse Verantwortung um das global gesetzte 1,5-Grad Ziel (COP 21) zu erreichen. Konkret müssen bis 2030 die von diesem Industriezweig ausgehenden Treibhausgasemissionen um 45 % reduziert werden. Neben neuen Konsummustern und Geschäftspraktiken gilt es insbesondere die produktionsbasierten Emissionen zu vermindern (Berg, 2020).
7

Využití prvků uměleckých výchov ve vyučování němčině jako cizímu jazyku (se zaměřením na dramapedagogiku a práci s obrazovou knihou "Královna barev" od Jutty Bauerové) / Using elements of art education in teaching German as a foreign language (with a focus on drama pedagogy and work with picture book "Queen of Color" by Jutta Bauer)

Moravčíková, Eva January 2011 (has links)
Title: Using elements of art education in teaching German as a foreign language (with a focus on drama pedagogy and work with picture book "Queen of Colour" by Jutta Bauer) Summary: My thesis is focused on integration of aesthetic elements into a German language lesson. Such elements help to improve students' language resources and language skills and they also help to develop their personality. The subject of my work is relation between the language and art - particular art education, namely dramatic, musical, and literary - partly - art education and their application in a foreign language lesson. This thesis is based on the theory of drama pedagogy and on analysis of an authentic foreign language literary text, namely on the picture book genre. The topics in the practical section are taken from artistic sources and were tested in particular sample lessons. Keywords: Aesthetic elements, Drama pedagogy, Music, Visual Material, Literary Text, Project-based Learning, Language resources, Language skills
8

In Vitro and In Vivo Applications of Fluorescence Cross-Correlation Spectroscopy

Staroske, Wolfgang 03 November 2010 (has links)
Fluorescence correlation spectroscopy (FCS) analyzes the fluctuations in the fluorescence intensity, which is emitted from a tiny excition volume, to obtain information about the concentration, the mobility, and the molecular interactions of labeled molecules. The more advanced fluorescence cross-correlation spectroscopy (FCCS) increases the precision in the determination of fl ow velocities and binding constants compared to standard FCS. The miniaturization in biomedical and chemical engineering has been developing rapidly, propelled by the vision of a fully functional laboratory on a single chip and its use in human therapeutics, for example, as implanted drug delivery system. A key requirement to fulfill this vision is the ability to handle small fl uid volumes. Handling liquids using the electrohydrodynamical principle circumvents many of the disadvantages of other systems. The complex flow pattern in the active region of such a pump could not be resolved by common tracking techniques. In this thesis, two-focus FCCS (2f-FCCS) was used to map the flow pro file inside a micropump. The high precision of 2f-FCCS in the determination of fl ow measurements even with small fluorescent particles allowed the measurement of the flow velocities induced by electrohydrodynamic forces acting on the solvent, while excluding the effects of dielectrophoretic forces acting on larger particles. Analysis of the fl ow data indicates a fl ow pattern that consists of two vortices of different size and opposite direction of rotation. The flow pattern derived by 2f-FCCS explains the observed complex particle trajectories in the force field and the accumulation of particles in well-de fined regions above the microelectrode array. In the second part of this thesis, the mechanism of RNA interference (RNAi) was studied by dual-color FCCS in vivo. RNAi is an evolutionary conserved gene silencing mechanism, which uses short double-stranded RNA molecules, called short interfering RNAs (siRNAs), as effector molecules. Due to its speci city and simplicity, RNAi yields a great potential for a widespread therapeutic use. To broaden the therapeutic applications, the in vivo stability of siRNAs has to be improved by chemical modi cations, but some of these modi fications inhibit the gene silencing mechanism. The presented FCCS assays are very well suited to investigate the individual assembly steps of RNAi machinery with very high specifi city and sensitivity in real time and to study the cleavage activity of the activated RNAi machinery. A direct correlation between activity of the RNAi machinery and the results from the FCCS measurements could be shown. The in fluence of several chemical modi cations on the assembly and activity of the RNAi machinery was investigated with these assays. / Fluoreszenz-Korrelations-Spektroskopie (FCS) analysiert die Fluktuationen im Fluoreszenzsignal eines kleinen angeregten Volumens, um Informationen über die Konzentration, die Bewegung und die Interaktionen der markierten Moleküle zu erhalten. Die Fluoreszenz-Kreuzkorrelations-Spektroskopie (FCCS) erhöht die Genauigkeit bei der Messung von Fließgeschwindigkeiten und Bindungskonstanten im Vergleich zur Standard-FCS. Die Miniaturisierung der Biomedizin und Chemie hat sich rapide entwickelt, angetrieben von der Vision eines kompletten Labors auf einem Chip und dem Einsatz dieses in der medizinischen Therapie, zum Beispiel als implantierter Medikamentenspender. Ein Schlüsselelement zur Erfüllung dieser Vision ist der Transport von kleinsten Flüssigkeitsmengen in diesen miniaturisierten Systemen. Der Transport von Flüssigkeiten mittels des elektrohydrodynamischen Prinzips umgeht viele Nachteile von anderen Systemen, allerdings zeigt eine solche Pumpe ein kompliziertes Strömungsbild in der aktiven Region, welches sich mit herkömmlichen Methoden wie Teilchenverfolgung nicht vermessen ließ. Hier wurde Zwei-Fokus-FCCS (2f-FCCS) genutzt, um das Strömungsbild in der Pumpe zu vermessen. Die hohe Genauigkeit der 2f-FCCS bei der Bestimmung von Fließgeschwindigkeiten auch mit kleinen fluoreszierenden Teilchen ermöglichte die Messung der Fließgeschwindigkeiten, aufgrund der auf das Lösungsmittel wirkenden elektrohydrodynamischen Kräfte, unter Ausschluss der auf größere Teilchen wirkenden dielektrophoretischen Kräfte. Die Analyse der Daten ergab, dass das Strömungsbild aus zwei entgegengesetzt rotierenden unterschiedlich großen Wirbeln besteht. Dieses Strömungsbild erklärt die komplizierten Teilchenbewegungsbahnen und die Anreicherung der Teilchen in klar abgegrenzten Bereichen über den Mikroelektroden. Im zweiten Teil dieser Arbeit wurde der RNAi-Mechanismus in lebenden Zellen mittels Zwei-Farben-FCCS untersucht. RNA Interferenz (RNAi) ist ein evolutionär erhaltener Geninaktivierungsmechanismus, der kurze doppelsträngige RNA Moleküle, so genannte kurze interferierende RNAs (siRNAs), als Effektormoleküle nutzt. Die Spezifi tät und Einfachheit der RNAi hat ihr ein weites Feld in der medikamentösen Therapie geöffnet. Zur Erweiterung dieses Feldes ist es nötig die Stabilität der siRNAs im Körper mittels chemischer Modi fikationen zu erhöhen. Einige dieser Modifikationen hemmen aber den RNAi-Mechanismus. Die hier vorgestellten FCCS Experimente sind sehr gut geeignet, um die einzelnen Schritte des Zusammenbaus der RNAi Maschinerie mit hoher Empfi ndlichkeit und Spezi fität in Echtzeit zu untersuchen und die Aktivität der RNAi Maschinerie zu studieren. Es konnte ein Zusammenhang zwischen der Aktivität der RNAi Maschinerie und den Ergebnissen der FCCS Messungen hergestellt werden. Der Einfluss von verschiedenen chemischen Modikationen auf den Zusammenbau und die Aktivität der RNAi Maschinerie wurde mit diesen neuartigen Methoden untersucht.
9

Hydrodynamical investigations of liquid ventilation by means of advanced optical measurement techniques

Janke, Thomas 20 August 2021 (has links)
Although liquid ventilation has been researched and studied for the last six decades, it did not achieve its expected optimal performance. Within this work, a deeper understanding of the fluid dynamics during liquid ventilation shall be gathered to extend the already available clinical knowledge about this ventilation strategy. In order to reach this goal, advanced optical flow measurement techniques are applied in different models of the human conductive airways to obtain global velocity fields, identifying prominent flow structures and to determine important dissolved oxygen transport paths. As the velocity measurements revealed, the evolving flow field is strongly dominated by secondary flow effects and is highly dependent on the local airway geometry. During the visualization experiments of the dissolved oxygen concentration fields, different transportation paths occur at inspirational and expirational flow. The initial concentration distribution can be linked to the underlying flow fields but decouples after the peak velocity phases. With higher flow rates/ tidal volumes, a more homogeneously distributed oxygen concentration can be reached.:List of Figures ....................................................................................... VII List of Tables ........................................................................................XIII Nomenclature ........................................................................................ XV 1 Introduction......................................................................................... 1 1.1 Motivation ........................................................................................1 1.2 Research objectives........................................................................... 3 1.3 Outline............................................................................................ 4 2 State of the art .................................................................................... 5 2.1 Liquid Ventilation............................................................................. 5 2.2 In vitro modeling.............................................................................. 8 2.3 Flow measurements ......................................................................... 11 2.4 Gas transport..................................................................................13 3 Flow field measurements ................................................................... 16 3.1 Hydrodynamic Model.......................................................................16 3.1.1 Lung replica ..........................................................................16 3.1.2 Flow parameter .....................................................................18 3.1.3 Limitations ...........................................................................22 3.2 Particle Tracking Velocimetry (PTV) ................................................24 3.2.1 Measurement principle ...........................................................24 3.2.2 Double-frame 2D-PTV ...........................................................25 3.2.3 Time-resolved 3D-PTV ..........................................................28 3.2.4 Phase-locked ensemble PTV ................................................... 31 3.3 Experimental set-up and measurement procedure ...............................33 3.3.1 Lung flow facility...................................................................33 3.3.2 2D-PTV configuration............................................................36 3.3.3 3D-PTV configuration............................................................36 3.4 Results & Discussion........................................................................38 3.4.1 Artificial lung........................................................................38 3.4.2 Realistic lung ........................................................................52 3.5 Conclusion ......................................................................................59 4 Oxygen transport ...............................................................................61 4.1 Hydrodynamic Model....................................................................... 61 4.1.1 Lung replica .......................................................................... 61 4.1.2 Flow parameter .....................................................................62 4.1.3 Limitations ...........................................................................65 4.2 Oxygen Sensitive Dye ......................................................................66 4.3 Experimental set-up......................................................................... 71 4.4 Results & Discussion........................................................................75 4.4.1 Constant flow rate .................................................................75 4.4.2 Oscillatory flow .....................................................................83 4.5 Conclusion ......................................................................................90 5 Summary............................................................................................ 92 6 Outlook .............................................................................................. 95 Bibliography ............................................................................................ 97 / Trotz intensiver Forschung in den letzten sechs Jahrzehnten, befindet sich die Flüssigkeitsbeatmung immernoch weit entfernt vom klinischen Alltag. Mit dieser Arbeit soll ein Beitrag geleistet werden, um das Wissen um die strömungsmechanischen Effekte während der Flüssigkeitsbeatmung zu vertiefen. Dazu werden verschiedene Modellexperimente durchgeführt, bei welchen moderne laseroptische Strömungsmessmethoden zum Einsatz kommen. Untersucht werden dabei unterschiedlich komplexe Geometrien der leitenden menschlichen Atemwege mit dem Ziel wesentliche Strömungsstrukturen, globale Geschwindigkeitsfelder und wichtige Transportwege des gelösten Sauerstoffs zu identifiziern. Die Geschwindigkeitsmessungen zeigen ein stark durch sekundäre Strömungseffekte dominiertes Geschwindigkeitsfeld, welches wesentlich von der lokalen Geometrie abhängig ist. Durch die qualitative und quantitative Erfassung der gelösten Sauerstoffkonzentrationsfelder können wichtige Transportwege aufgedeckt werden. Diese unterscheiden sich deutlich zwischen inspiratorischer und expiratorischer Strömungsrichtung. Die initialen Konzentrationsfelder stimmen mit den unterliegenden Geschwindigkeitsfeldern überein, unterscheiden sich ab der verzögernden Strömungsphase jedoch. Höhere Volumenströme/Tidalvolumen tragen dabei zu einer gleichmäßigeren Konzentrationsverteilung bei.:List of Figures ....................................................................................... VII List of Tables ........................................................................................XIII Nomenclature ........................................................................................ XV 1 Introduction......................................................................................... 1 1.1 Motivation ........................................................................................1 1.2 Research objectives........................................................................... 3 1.3 Outline............................................................................................ 4 2 State of the art .................................................................................... 5 2.1 Liquid Ventilation............................................................................. 5 2.2 In vitro modeling.............................................................................. 8 2.3 Flow measurements ......................................................................... 11 2.4 Gas transport..................................................................................13 3 Flow field measurements ................................................................... 16 3.1 Hydrodynamic Model.......................................................................16 3.1.1 Lung replica ..........................................................................16 3.1.2 Flow parameter .....................................................................18 3.1.3 Limitations ...........................................................................22 3.2 Particle Tracking Velocimetry (PTV) ................................................24 3.2.1 Measurement principle ...........................................................24 3.2.2 Double-frame 2D-PTV ...........................................................25 3.2.3 Time-resolved 3D-PTV ..........................................................28 3.2.4 Phase-locked ensemble PTV ................................................... 31 3.3 Experimental set-up and measurement procedure ...............................33 3.3.1 Lung flow facility...................................................................33 3.3.2 2D-PTV configuration............................................................36 3.3.3 3D-PTV configuration............................................................36 3.4 Results & Discussion........................................................................38 3.4.1 Artificial lung........................................................................38 3.4.2 Realistic lung ........................................................................52 3.5 Conclusion ......................................................................................59 4 Oxygen transport ...............................................................................61 4.1 Hydrodynamic Model....................................................................... 61 4.1.1 Lung replica .......................................................................... 61 4.1.2 Flow parameter .....................................................................62 4.1.3 Limitations ...........................................................................65 4.2 Oxygen Sensitive Dye ......................................................................66 4.3 Experimental set-up......................................................................... 71 4.4 Results & Discussion........................................................................75 4.4.1 Constant flow rate .................................................................75 4.4.2 Oscillatory flow .....................................................................83 4.5 Conclusion ......................................................................................90 5 Summary............................................................................................ 92 6 Outlook .............................................................................................. 95 Bibliography ............................................................................................ 97

Page generated in 0.1543 seconds