• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 488
  • 7
  • 6
  • 6
  • 6
  • 6
  • 4
  • 4
  • 4
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 510
  • 370
  • 362
  • 357
  • 353
  • 292
  • 287
  • 273
  • 122
  • 68
  • 58
  • 53
  • 53
  • 52
  • 45
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
211

Expansão rápida e lenta da maxila em pacientes com fissura labiopalatina completa e bilateral: avaliação por meio da tomografia computadorizada cone-beam / Rapid and slow maxillary expansion in patients with complete bilateral cleft lip and palate: assessment based on cone-beam computerized tomography

Almeida, Arací Malagodi de 11 July 2014 (has links)
Objetivo: O objetivo deste trabalho consistiu em avaliar e comparar os efeitos dentoesqueléticos dos expansores maxilares Haas/Hyrax e quadrihélice, em pacientes com fissura labiopalatina completa e bilateral. Material e Métodos: A amostra do estudo foi composta por 46 pacientes com fissura labiopalatina completa e bilateral, operados na infância, com atresia do arco dentário superior, na fase de dentadura mista tardia. Os pacientes foram aleatoriamente divididos em dois grupos de estudo, tratados com expansão rápida da maxila (ERM), com aparelhos ortopédicos Haas ou Hyrax (Grupo I, n=23) e com expansão lenta da maxila (ELM) por meio de expansores tipo quadrihélice (Grupo II, n=23). O exame de tomografia computadorizada cone-beam (i-Cat, Hartsfield, PA, EUA) foi realizado imediatamente pré-expansão e no mínimo 4 meses após a expansão. Foram mensuradas, por meio do Software Nemoscan (Nemotec, Madri, Espanha) e de modo duplo-cego, as dimensões transversais maxilares, a inclinação dos dentes posteriores, a espessura das tábuas ósseas vestibular e lingual e o nível da crista óssea alveolar vestibular, nas duas fases do estudo. As alterações interfases foram avaliadas por meio do teste t pareado (p<0,05). A comparação das características iniciais de cada grupo de estudo, assim como, a comparação intergrupos do efeito da expansão, foram realizadas por meio do teste t independente (p<0,05). Resultados: Não houve diferença estatisticamente significante entre ERM e ELM para as alterações interfases em nenhuma das variáveis analisadas. A ERM e a ELM apresentaram efeitos ortopédicos semelhantes em pacientes com fissura labiopalatina completa e bilateral, com aumentos transversais decrescentes do nível do arco dentário em direção à cavidade nasal. Ambas as modalidades de expansão ocasionaram inclinação vestibular dos dentes posteriores em magnitudes semelhantes e incitaram suaves reduções da espessura da tábua óssea vestibular (0,57mm) e do nível da crista óssea vestibular (0,54mm), sem significância clínica. Conclusão: Tanto a ERM quanto a ELM foram efetivas para produzir efeitos ortopédicos na maxila em crianças com fissura completa e bilateral, causando movimentos de inclinação vestibular dos molares, porém sem repercussões nas tábuas ósseas vestibulares ou no nível das cristas marginais. / Objective: The purpose of this study was to evaluate and to compare the dentoskeletal effects of the Haas/Hyrax and Quadhelix maxillary expanders in patients with complete bilateral cleft lip and palate. Material and Method: The study sample was comprised of 46 patients with complete bilateral cleft lip and palate, operated on during childhood, with constriction of the upper dental arch, in the late mixed dentition. The patients were randomly divided into two groups and treated with a rapid maxillary expansion (RME) with the Haas or Hyrax orthopedic expander (Group I, n=23) and with a slow maxillary expansion (SME) with the Quadhelix expander (Group II, n=23). The cone-beam computerized tomography (i-Cat, Hartsfield, PA, USA) was performed immediately prior to the expansion and at least 4 months post-expansion. Using the multiplanar reconstruction resource, the following measurements were evaluated with Nemoscan Software (Nemotec, Madrid, Spain) in a double-blind manner: maxillary transverse dimensions, inclination of the posterior teeth, thickness of the buccal and lingual bone plate and level of the buccal alveolar bone crest in both phases of the study. The interphase alterations were evaluated with the paired t test (p<0.05). The comparison of the initial characteristics of each study group as well as the intergroup comparison of the expansion effects were performed with the independent t test (p<0.05). The tested null hypothesis is that both expanders present similar dentoskeletal effects. Results: no statistically significant differences were found between RME and SME for the analyzed variables. RME and SME presented similar orthopedic effects in patients with complete bilateral cleft lip and palate, with the transverse increments decreasing from the dental arch level toward the nasal cavity. Both expansion devices produced similar buccal inclination of the posterior teeth and similar and mild reduction of the bone plate thickness (0.57 mm) and of the bucal bone crest (0.54 mm), with no clinical significance. Conclusion: Both RME and SME were effective in producing orthopedic effects on the maxilla, causing inclination and buccal movement of the molars without major consequences to the buccal bone plates or the marginal crests. The null hypothesis tested in the present study was confirmed. Both expanders presented similar dentoskeletal effects.
212

Acurácia de medidas lineares em softwares de planejamento de implantes sobre imagens de mandibulas atróficas obtidas por tomografias computadorizadas de feixe cônico com diferentes protocolos de aquisição / Accuracy of linear measurements in implant planning software on images of atrophic jaws obtained by cone beam computed tomography with different acquisition protocols

Barbosa, Jorge de Sá 13 June 2014 (has links)
O objetivo neste estudo foi avaliar a acurácia de softwares de planejamento de implantes sobre imagens de mandíbulas atróficas obtidas por tomografia computadorizada de feixe cônico (TCFC) com diferentes protocolos de aquisição. Foram utilizadas 10 mandíbulas desdentadas totais que receberam 8 marcações em regiões normalmente utilizadas para colocação de implantes (4 em região anterior e 4 em região posterior), sobre estas foram aderidos fios ortodônticos a fim de padronizar as regiões. Então as mandíbulas foram submetidas à TCFC com 2 protocolos de aquisição, P1 (voxel 0,25mm) e P2 (voxel 0,125mm), e as imagens analisadas por 3 softwares de planejamento de implantes, sendo eles: Xoran versão 5.0 (XR) (Xoran Technologies® Inc, Ann Harbor, MI, USA); DentalSlice versão 2010 (DS) (Bioparts®, Brasília, Brasil) e OsiriX 1.2 (OX) (Pixmeo®, Genebra, Suiça). Foram realizadas medidas lineares nas regiões de maior extremidade em altura, largura , e altura da crista do rebordo até o teto do canal mandibular. Exatamente sobre as 8 demarcações as mandíbulas foram seccionadas para mensuração direta por meio de paquímetro digital. A correlação intraclasse (ICC) foi utilizada para calcular a confiabilidade intraexaminador (ICC=0,997) e interxaminador (ICC=0,995) obtendo uma excelente reprodutibilidade, assim para P1 e P2 em todos os softwares analisados para todos os tipos de mensurações. Para análise da precisão, os dados foram submetidos a análise estatística pelo teste t de Student, analisados entre dois grupos, e posteriormente a frequência de significância foi analisada pelo teste Exato de Fisher. As imagens mensuradas no software Xoran com voxel 0,125mm obtiveram resultados mais próximos das medidas reais, assim como o volume total de imagens de todos os softwares. Os resultados mostraram diferença entre os softwares Xoran e Osirix para os diferentes voxels, sugerindo apenas o voxel de 0,125mm para o uso do OsiriX em mandíbulas atróficas. / The objective of this study was to evaluate the accuracy of implant planning software of images assessed from atrophic jaws using cone beam computed tomography (CBCT) with different acquisition protocols. Ten total edentulous jaws received 8 markings in areas normally used for implant placement (4 in anterior and 4 posterior region) were used on orthodontic wires bonded to standardize regions. The jaws were scaneded CBCT 2 acquisition protocols , P1 (0.25 mm voxel) and P2 (0.125 mm voxel) , and analyzed by 3 implant planning software images: Xoran version 5.0 (XR) (Xoran Technologies ® Inc. , Ann Arbor , MI , USA) ; DentalSlice 2010 version (DS) (Bioparts ®, Brasilia, Brazil) and OsiriX 1.2 (OX) (Pixmeo ®, Geneva, Switzerland). Linear measurements were made in regions of higher end in height, width , and height of the crest of the ridge to the roof of the mandibular canal. Just about the demarcations jaws were sectioned for direct measurement by digital caliper. The intraclass correlation coefficient (ICC) was used to calculate the intra-rater reliability (ICC = 0.997) and interxaminador (ICC = 0.995) obtaining excellent reproducibility. For accuracy analysis , the data were analyzed statistically by the \" t test , analyzed between two groups, and then the frequency of significance was analyzed by Fisher exact test. The images measured in Xoran software with 0.125 mm voxel got closer to the actual outcomes measures, as well as the total volume of all software images . The results showed differences between the Xoran and OsiriX software for different voxels , suggesting only 0.125 mm voxel for using OsiriX in atrophic jaws .
213

Estudo das grandezas tomográficas dos tecidos moles faciais em repouso e em sorriso amplo e suas correlações com os tipos faciais / Tomographic study of the facial soft tissue measures at rest and wide smile and their correlation with the facial types

Martins, Luciana Flaquer 12 November 2010 (has links)
Em ortodontia, as características dos tecidos moles e do padrão facial representam um papel importante no diagnóstico e planejamento do tratamento ortodôntico ou ortodôntico/cirúrgico. Este estudo visou determinar quais são as características dos tecidos moles faciais nas fases em repouso e em sorriso amplo, bem como avaliar o comportamento dinâmico desses tecidos na transição da posição de repouso para a de sorriso amplo e qual a sua possível relação com o tipo facial. Para tanto, analisamos uma amostra composta por quarenta e oito adultos jovens, do gênero feminino, que apresentavam faces equilibradas e selamento labial passivo. Tomografias computadorizadas de feixe cônico (TCFC) nas fases em repouso e em sorriso amplo foram efetuadas em toda a amostra, que foi segmentada em três grupos e os indivíduos alocados de acordo com o tipo facial a que pertenciam (Braquifacial, Mesofacial e Dolicofacial determinado inicialmente pelo método antropométrico em fotografias faciais padronizadas). A análise das características tegumentares de lábios, nariz, malar e mento foi feita em cortes tomográficos sagitais, axiais e em visão frontal, e os resultados obtidos em cada tipo facial comparados entre si. Para a análise estática das estruturas faciais, tanto na fase em repouso, como na fase em sorriso amplo, não houve diferenciação entre os tipos faciais em nenhuma das variáveis estudadas. A análise dinâmica evidenciou que o tipo braquifacial é mais sensível à movimentação, apresentando maior contração sagital do lábio superior, porém, o deslocamento labial apresentado por este tipo facial produz um sorriso pouco amplo, com menor área de exposição dentária quando comparado aos demais tipos faciais. Com este trabalho, foi possível corroborar que, em uma face equilibrada, a posição do lábio superior deve ser à frente do lábio inferior e este à frente do pogônio e determinar que o tipo facial não exerce influência sobre o posicionamento dessas estruturas. Em adição, observamos que a utilização de tomografias computadorizadas de feixe cônico pode ser de grande valia para o estudo de características crânio faciais. / In orthodontics, skeletal and soft tissue characteristics pay an important role in diagnosis and planning of orthodontic treatment or orthognathic surgery and orthodontic combined treatment. This study aim to determine what are the characteristics of facial soft tissue, in two phases: at rest and wide smile, and assessing the dynamic behavior of these tissues in the transition from the resting position for the widest smile and what their possible relationship to the facial type. Therefore, we analyzed a sample of forty-eight young adult females, who had presented balanced facial profile and passive labial sealing. Cone beam computed tomography (CBCT) stages at rest and wide smile were performed on the entire sample, which was divided into three groups and individuals allocated according to facial type (brachyfacial, mesofacial dolichofacial and - given initially by anthropometric method in standardized facial photographs). The analysis of the characteristics of soft tissue of the lips, nose, cheek and chin were performed in sagital, axial and frontal vision of tomographic views, and the results for each facial type compared. For static analysis of facial structures, both stages, when at rest and in wide smile, there was no differentiation between facial types in any of the variables. The dynamic analysis showed that the brachyfacial type is more sensitive to movement, with greater sagittal contraction of lip, however, the lip movement presented by this type of face produces a narrow smile, with a smaller teeth display area when compared to other facial types . With this study, we corroborate that, in a face with balanced features, the upper lip position must be in front of the lower lip and this in front of the pogonion and determined that the facial type does not impact the position of these structures. In addition, we observed that the use of cone beam computed tomography may be valuable for the study of craniofacial features.
214

Avaliação volumétrica de defeitos ósseos em fissuras de rebordo alveolar e palato duro por meio da 3D-TC multislice e feixe cônico / Volumetric assessment of hard palate and alveolar cleft using multislice and cone beam 3DCT

Albuquerque, Marco Antonio Portela 11 November 2010 (has links)
As fissuras de rebordo alveolar e palato duro estão entre as malformações mais frequentes do corpo humano, podendo causar extensas deformidades ósseas faciais, com implicações biopsíquico-sociais marcantes. A avaliação da extensão desses defeitos ósseos, através de exames por imagem, tem sido feita com o objetivo de diagnosticar e planejar a terapêutica reabilitadora dos pacientes. O presente estudo tem por objetivo desenvolver uma metodologia de pós-processamento de imagens tomográficas para avaliação volumétrica de defeitos ósseos confeccionados em palato duro e rebordo alveolar de crânios macerados, mimetizando fissuras trans-forâmens unilaterais, e verificar a aplicabilidade clínica do Tomógrafo Computadorizado espiral Multislice e do tomógrafo computadorizado por feixe cônico na análise desses defeitos. Para tanto, nove crânios provenientes da Faculdade Cathedral, da cidade de Boa Vista- RR, foram escaneados em um Tomógrafo Computadorizado Multislice pertencente ao Hospital Geral de Roraima e em um tomógrafo computadorizado por feixe cônico de uma clínica privada, na cidade de Fortaleza-CE. As imagens foram, posteriormente, encaminhadas para análise ao Laboratório em Terceira Dimensão(LAB-3D) da Faculdade de Odontologia da USP, utilizando-se uma estação de trabalho independente e aplicando-se programas específicos de computação gráfica. Todas as imagens foram analisadas por dois examinadores, individualmente e em tempos distintos, por duas vezes, com o objetivo de processarmos análises intra e interexaminadores. Para a análise da metodologia de processamento de imagens, comparamos os resultados obtidos pelo Tomógrafo multislice utilizando crânios sem cera e com cera de modelagem número 07, na região do defeito ósseo, para auxiliar no seu delineamento, durante o pós-processamento das imagens tomográficas. Foram também avaliados os resultados volumétricos obtidos nos dois tipos de tomógrafos,com o objetivo de verificar a aplicabilidade dessas tecnologias na avaliação volumétrica dos defeitos ósseos fissurais e de comparar os resultados obtidos por cada uma delas. Todos os resultados foram comparados com os valores estabelecidos pelo padrão - ouro de nossa análise, que foram obtidos através do princípio de Arquimedes de deslocamento de água dos modelos de cera que foram utilizados. Os resultados estatísticos demonstraram que a metodologia de processamento das imagens tomográficas apresentou uma eficácia bastante elevada (p=0,995), sendo considerada eficiente na avaliação volumétrica de defeitos ósseos fissurais. Com relação aos tomógrafos utilizados, observamos que tanto o multislice como o por feixe cônico também apresentaram resultados satisfatórios, apresentando grande confiabilidade para o estudo do volume dos defeitos ósseos fissurais (p=0,997 e p=0,981, respectivamente), não havendo diferença nos resultados encontrados por eles. As análises intra e interobservadores nos dois tipos de tomógrafos não demonstraram diferença estatisticamente significativa. Os resultados evidenciaram que, independente do tipo de tomógrafo utilizado e do avaliador, as medidas obtidas são estatisticamente iguais às conseguidas pelo padrão-ouro de nossa análise. A aplicabilidade clínica de nossa pesquisa demonstrou ser direta e imediata, sendo importante no processo diagnóstico/terapêutico dos pacientes portadores de fissuras de rebordo alveolar e palato duro. / Oral clefts are one of the most frequent malformations of the human body, causing extensive facial bone deformities, compromising biological, psychic and social the individuals affected. Multislice CT and CBCT have been used to assess the volume of bone defect with the goal of diagnosis and rehabilitative therapy planning of the patients. The aim of this study were to develop a methodology for post-processing of tomographic images for volumetric assessment of bone defects made in the hard palate and alveolar ridge of dry skulls, mimicking unilateral trans-foramen clefts; and to determine the clinical applicability of multislice spiral computed tomography, and cone beam computed tomography in the analysis of these defects. Nine dry skulls from the Cathedral College in Boa Vista-RR were scanned on a multislice CT scanner at the Hospital Geral de Roraima and a cone beam computed tomography in a private clinic in Fortaleza-CE. The images were sent for analysis at Three Dimensional Laboratory (LAD-3D) of the Dentistry School, São Paulo University, using an independent workstation and implementing specific computer graphics programs. All images were analyzed by two examiners at different times and twice to proceed the intra and inter-examiners analysis. For analysis the methodology of image processing, we compared the results obtained by multislice CT using skulls with and without wax model in the region of bone defect. It was also analyzed the same images in both types of CT scanners in order to determine the applicability of these radiographic techniques in assessing volume of the clefts and to compare the results. All results were compared with the gold standard of our analysis, which was obtained by Archimedes principle of water displacement of wax models. The statistical results showed that the post processing methodology of tomographic images showed a high efficiency (p = 0.995) and was considered an efficient method for volumetric assessment of fissure bone defects. It was also observed that both multislice CT and cone beam CT showed excellent results with high reliability in the study of the volume of bone defects (p = 0.997 and p = 0.981, respectively), with no difference in performance between them. Analysis of intra-and inter-observer in the two types of CT scanners showed no statistically significant difference. The results demonstrate that independent of the type of CT scanner and the appraiser, the measurements are statistically equal to the gold standard obtained by our analysis. The clinical applicability of our research has shown to be immediate and direct, and it is important for the diagnostic and therapeutic process of patients with oral cleft.
215

Sintonia dos parâmetros de operação do primeiro estágio de aceleração do Mícroton do IFUSP / Tuning the Operational Parameters of the First Microtron Stage

Jahnke, Cristiane 14 March 2012 (has links)
O Laboratório do Acelerador Linear (LAL) do Instituto de Física da Universidade de São Paulo está construindo um acelerador de elétrons do tipo Mícrotron. O acelerador possui dois estágios de aceleração: o Mícrotron booster e o Mícrotron Principal. Atualmente, o sistema injetor do acelerador, que é um acelerador linear, dispõe de um feixe de elétrons de 1,9 MeV. Este feixe será inserido no primeiro estágio de aceleração, o Mícrotron booster, que já está construído e será testado em breve. Sua função é elevar a energia do feixe para 5 MeV. O objetivo deste trabalho é o de otimizar os parâmetros de operação do Mícrotron booster por meio de simulação. Também tivemos como objetivo estudar a viabilidade da adaptação do projeto original, com feixe de entrada de 1,765 MeV, para um feixe de entrada de 1,9 MeV. Tendo como foco principal encontrar a admitância do acelerador, foram desenvolvidas algumas rotinas de simulação. A admitância do Mícrotron booster para um feixe de 1,765 MeV foi calculada em 3,08 pi mm.mrad, 0,58 pi mm.mrad e 0,38 pi keV.rad para os espaços de fase horizontal, vertical e longitudinal, respectivamente. Para o feixe de 1,9 MeV, uma condição de aceleração foi encontrada e os valores de admitância foram 3,65 pi mm.mrad, 0,62 pi mm.mrad e 0,77 pi keV.rad para os mesmos espaços de fase. Dados de caracterizações do feixe, realizados em trabalhos anteriores foram utilizados para determinar a configuração das lentes quadrupolares responsáveis pela inserção do feixe no acelerador. Tais simulações darão suporte ao início de operação do Mícrotron booster, auxiliando na determinação dos parâmetros iniciais de operação e otimização dos parâmetros finais. / The Laboratório do Acelerador Linear is building a racetrack microtron electron accelerator. It has two acceleration stages: the booster and the main microtron. The injection system has already been commissioned and is delivering a 1.9-MeV continuous wave beam. This beam will be injected in the booster stage, which is ready to be commissioned, and should increase the energy to 5 MeV. The aim of this work is to optimize the operation parameters of the booster stage by means of simulation tools. We also studied the feasibility of injecting the 1.9 MeV beam in the booster, which has been designed to operate with a 1.765 MeV beam. Some simulation routines had to be developed in order to determine the admittance of the booster stage. For the 1.765 MeV beam the admittances were determined to be 3.08 pi mm.mrad, 0.58 pi mm.mrad, and 0.38 pi keV.rad for the transverse horizontal, transverse vertical, and longitudinal phase spaces, respectively. For the 1.9 MeV injection beam we were able to find a viable acceleration condition, with slightly better admittances: 3.65 pi mm.mrad, 0.62 pi mm.mrad, and 0.77 pi keV.rad, for the same phase spaces cited above. The injection beam has been characterized previously, and the available data were used, in the simulation codes, to match the transverse beam emittances of the injector to the transverse beam admittances of the booster. The phase space manipulations were accomplished by tuning a quadrupole triplet placed before the booster entrance. These simulations are intended as a supporting tool for the commissioning of the booster stage, helping the experimental determination of the working parameters and their optimization.
216

Efeitos periodontais da movimentação dentária de molares inferiores para área de rebordo alveolar atrófico / Periodontal effects of lower molar movement to atrophic areas

Patrícia Bittencourt Dutra dos Santos 12 September 2014 (has links)
Objetivos: Avaliar a espessura da tábua óssea e nível de crista vestibular e lingual de segundos pré-molares e molares após o tratamento ortodôntico em pacientes com perda do primeiro molar inferior. Além de investigar presença de fenestrações e o comportamento dos parâmetros clínicos periodontais. Métodos: A amostra foi composta de 36 hemiarcos os quais foram divididos em 3 grupos: Grupo Abertura (GA - 15 molares verticalizados), Grupo Fechamento (GF - 12 molares mesializados para área de rebordo atrófico) e Grupo Controle (GC 9 hemiarcos sem perdas dentárias). Após a movimentação, os pacientes foram submetidos a exames de tomografia computadorizada de feixe cônico (TCFC) seguindo protocolos de 0,2 mm de voxel a 6 cm de FOV, no aparelho i-CAT Cone-Beam 3-D Dental Imaging System. Todas as medições foram realizadas no Dolphin em cortes parassagitais e avaliadas nas faces vestibular e lingual. Presença de fenestrações, posição do ápice radicular e recobrimento radicular também foram avaliados. Além disso, profundidade de sondagem, índice de sangramento gengival, recessão e índice de placa foram mensurados antes e depois do tratamento. A comparação intergrupos do nível da crista e espessura óssea foi realizado com o ANOVA seguido do teste de Tukey. A comparação intergrupos para a presença de fenestração e a posição do ápice radicular foi avaliada usando o Qui-quadrado enquanto o recobrimento radicular foi comparado pelo teste de Kruskal-wallis e Mann-Whitney. Os parâmetros clínicos periodontais foram comparados por meio do teste t pareado (intragrupos) e ANOVA e Tukey (intergrupos). Resultados: Não houve diferença significante entre os grupos para nenhuma medição realizada no segundo pré-molar. Houve um menor nível da crista óssea vestibular e lingual para o grupo fechamento. Não houve diferença para a espessura da tábua óssea e para a presença de fenestrações entre os grupos. GF apresentou ápices radiculares mais centralizados, enquanto os demais grupos mostraram raízes ligeiramente deslocadas para vestibular. Na avaliação dos parâmetros clínicos periodontais, não houve diferença para a avaliação intragrupos, mas em uma avaliação intergrupos, o índice de sangramento gengival no GA foi o dobro dos demais grupos. Conclusões: Dentes mesializados apresentam crista óssea suavemente deslocada para apical em relação aos molares verticalizados e somente alinhados e nivelados. A pequena diferença não compromete essa indicação terapêutica. / Objective: The aim of this study was to evaluate the buccal and lingual bone plate thickness measurements and dehiscences of mandibular second premolars and molars after orthodontic treatment in patients with loss of first permanent molar and to investigate periodontal parameters behavior. Methods: The sample comprised 36 hemiarchs which were divided into 3 groups: GA (15 uprighted molars), GF (12 molars that were moved to atrophic areas) and GC (control grup 9 molars aligned and leveled). Posttreatment CBCT exams of the mandible were taken with voxel dimensions of 0.2 mm using the i-CAT Cone-Beam 3-D Dental Imaging System. Linear measurements were performed using the Dolphin software on cross section slices. Dehiscences and bone plate thickness measurements at middle of root were taken in buccal and lingual surfaces. Fenestrations, root apex position e root coverage were evaluated. Besides, the probing depth, plaque index, recession level and gingival bleeding index were evaluated before and after molar movement. The comparison between groups regarding dehiscence and bone thickness was performed by ANOVA followed by Tukey test. Presence of fenestration and root apex position were investigated by chi-square test. Root coverage measurements were performed by kruskal-wallis and Mann-Whitney. Periodontal parameters investigation were performed by Student t test (intergroup) and ANOVA and Tukey test (intergroup). Results: There were no significant differences for premolars measurements. Other than that, the distance between the CEJ and the alveolar crest was significant higher for molars that were moved to atrophic areas without differences on bone thickness. There was no difference for presence of fenestration between groups. GF showed centralized root apex, while others groups showed a small buccal root displacement. GF showed lower root coverage than GA and GC. Regarding periodontal parameters, there was no differences for intragroup comparison, but bleeding gingival index was higher on GA at end of treatment. Conclusions: It was concluded that molar movement to atrophic areas increased buccal and lingual dehiscences and this movement should be indicated with caution.
217

Avaliação tomográfica da pneumatização dos seios maxilares em regiões de perdas dentárias unitárias: estudo retrospectivo / Tomographic evaluation of maxillary sinus floor pneumatization in regions of single tooth loss: a cross-sectional study

Marília Cabral Cavalcanti de Morais Guerra 12 July 2017 (has links)
A perda dentária tem como consequência a atrofia óssea. Além disso, em regiões posteriores da maxila, a pneumatização do assoalho do seio maxilar (ASM) pode comprometer a instalação de implantes dentários em uma posição protética ideal. O objetivo deste estudo foi avaliar em imagens de tomografia computadorizada de feixe cônico (TCFC) a estimativa da pneumatização (EP) do ASM após perda dentária unitária em região posterior da maxila. 183 imagens de TCFC foram analisadas bilateralmente e divididas em 2 grupos: lado edêntulo (LE) - região edêntula unitária em segundo pré-molar, primeiro ou segundo molares superiores; lado dentado (LD) - região contralateral homóloga à região do LE, com dente presente. Os seguintes parâmetros foram avaliados para comparação LE versus LD: altura do seio (AS), desfecho primário, e área do seio maxilar (SM). A EP (diferença de AS do LE menos LD) e a altura do rebordo (AR - analisada apenas no LE) foram comparadas de acordo com tipo de dente e presença de pneumatização entre as raízes (PR) do LD. Além disso, o rebordo cicatrizado foi categorizado de acordo com a opção terapêutica para maxilar posterior. Os resultados mostraram que o LE apresentou a AS maior que o LD (p<0,05) (6,90 ± 3,15 mm e 6,0 ± 3,01 mm, para LE e LD respectivamente e a EP de 0,9 ± 2,93 mm). Ao separar EP por tipo de dente observou-se que os segundos pré-molares e segundos molares apresentaram valores próximos (1,36 ± 2,43 e 1,21 ± 2,98 mm, respectivamente), enquanto que os primeiros molares apresentaram valores menores (0,55 ± 3,03 mm) (p>0,05). Ao separar os dados de EP de acordo com a presença da pneumatização no LD, observou-se que a maioria dos dentes com esta condição foram os primeiros molares (36 em 43). A EP na presença dessa condição foi de -0,26 ± 2,82 mm, enquanto que na ausência de PR, a EP foi de 1,22 ± 2,99 (p<0,05). Em relação aos parâmetros da crista alveolar, o rebordo cicatrizado apresentou menor altura que às cristas alveolares palatina e vestibular. 54% dos casos de molares que apresentaram pneumatização entre as raízes obtiveram AR < 5mm, sugerindo necessidade de enxerto para uma futura instalação de implante dentário. Portanto, podemos concluir que perdas dentárias em região posterior de maxila favorecem a pneumatização do ASM e que esta varia de acordo com o tipo de dente. Além disso, a identificação de pneumatização entre as raízes parece indicar uma maior tendência à necessidade de cirurgias de levantamento de seio. / The aim of this study was to evaluate the estimation of MSF pneumatization (EP) after single tooth loss in the posterior maxilla region in cone beam computed tomography (CBCT) images. 183 CBCT images were analyzed bilaterally and divided into 2 groups: edentulous side (ES) - edentulous single region in the maxillary second premolar, first or second molars; Tooth side (TS) - contralateral region homologous to the ES region, with tooth present. The following parameters were evaluated for ES vs TS: sinus height (SH), primary outcome, and maxillary sinus area (MSA). The EP (SH difference between ES and TS) and ridge height (RH - analyzed only in ES) were compared according to tooth type and the presence of pneumatization between roots (PR) in TS. In addition, the healed ridge was categorized according to the therapeutic option for posterior maxilla. The results showed that the ES presented a higher SH than the TS (p <0.001) (6.90 ± 3.15 mm and 6.0 ± 3.01 mm for ES and TS respectively, and the EP of 0.9 ± 2.93 mm). When separating EP by tooth type, it was observed that the second premolars and second molars presented close values (1.36 ± 2.43 and 1.21 ± 2.98 mm, respectively), whereas the first molars presented minor values (0.55 ± 3.03 mm) (p>0.001). When separating the PR data according to the presence of pneumatization in the TS, it was observed that the majority of the teeth with this condition were the first molars (36 in 43). PE in the presence of this condition was -0.26 ± 2.82 mm, whereas in the absence of PR, the PE was 1.22 ± 2.99 (p <0.001). Regarding the parameters of the alveolar ridge, the healed ridge presented lower height than the palatal and vestibular alveolar ridges. 54% of the cases of molars that presented pneumatization between the roots obtained RH < 5mm, suggesting the need of grafting for a future installation of dental implant. Therefore, we can conclude that tooth loss in the maxillary posterior region favors the pneumatization of the MSF and it varies according to the type of tooth. In addition, the identification of pneumatization between the roots seems to indicate a greater tendency to the need for sinus lift surgeries.
218

Processo de clarificação de caldo de cana-de-açúcar aplicando elétrons acelerados / Sugarcane juice clarification applying electron beam technology

Roberta Bergamin Lima 28 September 2012 (has links)
O caldo de cana-de-açúcar é um líquido opaco, viscoso, de cor amarelada esverdeada, de composição química complexa e variável, é utilizado para produção de cachaça, rapadura, álcool e principalmente açúcar. Em sua composição possui além de açúcares uma série de compostos que conferem cor e que pode interferir na cor do produto final gerado, sendo que dentre estes compostos podemos citar a clorofila, compostos fenólicos e flavonoides. Para produção de um açúcar de boa qualidade e aceitação comercial, o caldo passa pelo processo de sulfitação, que promove a redução da cor do caldo através do contato deste com o anidrido sulfuroso (SO2), gerando um açúcar mais branco. No entanto, este açúcar por obter resíduos de enxofre, sofre restrições do mercado externo, o que vem incentivando o desenvolvimento de diversas técnicas alternativas de clarificação a fim de se produzir um açúcar mais branco e que atenda as exigências do mercado externo. Contudo, o presente trabalho avaliou o efeito da radiação por elétrons acelerados em caldo de cana-de-açúcar, comparando-os a testes preliminares realizados com caldo de cana-de-açúcar tratados com irradiação gama. As amostras foram irradiadas nas doses de 5, 10 e 20 kGy em ambos os tipos de radiação e foram comparadas com uma amostra controle in natura. Os resultados mostraram que houve um aumento significativo (p<0,05) dos compostos fenólicos em ambos os tratamentos, provavelmente por que ao sofrer irradiação os ácidos fenólicos se tornam mais disponíveis na matriz. Observou-se ainda aumento dos níveis de açúcares redutores (glicose e frutose) tanto para as amostras irradiadas com radiação gama como para feixe de elétrons, fato verificado por análises cromatográficas quantitativas realizadas no caldo de cana-de-açúcar tratado com feixe de elétrons. Foi ainda observado que embora tenha ocorrido algumas alterações significativas (p<0,05) quanto aos parâmetros, que caracterizam o perfil do caldo, avaliados com Brix, pH, acidez total titulável, o trabalho manteve seu propósito de redução da cor ICUMSA do caldo de cana-de-açúcar em ambos os tratamentos sendo que essa redução representou aproximadamente 49% da amostra controle em relação a dose irradiada a 20 kGy, para feixe de elétrons e cerca de 30% para amostras irradiadas em fonte de cobalto-60. Mostrando que ambas as técnicas são eficazes na redução da cor do caldo de cana-de-açúcar, sendo que o método de irradiação por acelerador de elétrons apresenta vantagens em relação à irradiação gama além de obter maior índice de redução da cor, é o método de maior produção (m3/h) e mais seguro, segundo as regras de proteção radiológica. / The sugar cane juice is a liquid opaque, viscous, yellowish green, its chemical composition is complex and variable, is used for the production of spirit, molasses, alcohol, and mainly sugar. In its composition the sugar cane juice has a series of compounds as sugars and many others compounds which produces color and can interfere in the color of the final product produced, and among these we can mention the chlorophyll, phenolic compounds and flavanoids. To produce a sugar of good commercial quality and acceptability the sugar cane juice pass to the process of sulfitation, which promotes the reduction of color of the juice by its contact with the SO2, making a sugar whiter. However, these sugars that have residue of sulfur suffer some restrictions on the foreign market. In this sense many techniques has been discussed, to looking for to produce a white sugar and that respect the requirements of the foreign markets. Although, this work evaluated the effect of radiation of electron beam in a sugar cane juice and compared this results with a preliminary tests with sugar cane juice treated with gamma irradiation. The samples were radiated at 5, 10 and 20 kGy doses in both of irradiation and compared a sample (control) without treatment. The results showed a significant increase (p<0.05) of phenolic compounds, in both treatments, probably because the radiation of sugar cane juice become phenolic acids more available in the juice. We also observed increased levels of reducing sugars (glucose and fructose) for the samples irradiated with gamma irradiation and for electron beam, a fact verified by quantitative chromatographic analyzes performed in the sugar cane juice treated with electron beam. Even that we observe that these treatments although has shown some significant changes to the parameters that characterizing the profile of the juice like Brix, pH, titratable acidity, was able to reduce de color ICUMSA of the sugar cane juice in both of treatments with irradiation. By electron beam irradiation, the sugarcane juice reduce about 49% its color, compared the control and the sample that receive dose of 20 kGy, and the gamma irradiation the juice reduced about 30% color the control compared with samples irradiated in 20 kGy. These results show us that both techniques are effective in reducing the color ICUMSA of the sugar cane juice, and the method of irradiation by electron accelerator has advantages in addition to gamma irradiation because also cause greater reduction color, is the method of higher production (m3 / h) and safer, according to the rules of radiological protection.
219

Produção da liga Ni-Ti com efeito de memória de forma em forno de fusão por feixe eletrônico e sua caracterização.

Eduardo Massao Sashihara 29 May 2007 (has links)
A primeira etapa deste trabalho consiste de uma descrição geral das propriedades mecânicas, temperaturas de transformação e características microestruturais de uma liga Ni-50,2Ti(%at.) com Efeito de Memória de Forma (EMF) previamente produzida via fusão por feixe de elétrons (EBM). O comportamento mecânico foi estudado por ensaios de tração em condições controladas de temperatura e deformação. As curvas de tensão-deformação à temperatura ambiente (amostra no estado martensítico) apresentaram um platô de tensão compreendido entre 150 a 190MPa após a deformação elástica da martensita. Uma recuperação média total (RE + REMF) de 80% foi observada experimentalmente para uma amplitude de deformação variando de 2 a 8%. A influência da temperatura na resistência mecânica também foi verificada com a amostra no estado austenítico ensaiada a 100C e a 120C. Por microscopia óptica (MO) foi verificado que o material apresenta bandas de martensita deformada antes da solubilização, e uma estrutura bastante homogênea com contornos de grão após a solubilização. Além disso, foram verificados o desaparecimento e o reaparecimento do relevo de superfície devido à transformação martensítica reversa e direta, respectivamente, durante o aquecimento e resfriamento da amostra polida eletroliticamente. Por microscopia eletrônica de varredura (MEV) verificou-se que, mesmo no estado não solubilizado, a amostra apresenta fratura dúctil com presença de "dimples". Após solubilização e/ou envelhecimento, a amostra apresenta uma deformação plástica razoável com alongamento total acima de 20%. A segunda etapa deste trabalho mostra a importância de alguns parâmetros do processo na produção da liga Ni-Ti com EMF via EBM, tais como: intensidade de corrente e tempo de exposição do feixe de elétrons, velocidade longitudinal, rotação e configuração da barra de alimentação. Os lingotes foram produzidos a partir de um forno de 30kW, e posteriormente, caracterizados nos estados: bruto de fusão, solubilizado e envelhecido. Os dados de dureza revelam a influência destes tratamentos na formação de precipitados dentro da matriz Ni-Ti. Todos os lingotes apresentaram uma superfície lisa e brilhante e quase sem oxidação. As macro e microestruturas das amostras foram analisadas por MO e MEV. Dependendo da intensidade da corrente, os lingotes apresentaram uma estrutura grosseira formada principalmente por grãos colunares, ou uma estrutura refinada formada por grãos colunares e equiaxiais. Conseqüentemente, foi verificada uma dureza maior, sem vazios internos e uma maior fração volumétrica de precipitados no segundo lingote. As análises por espectroscopia por dispersão de energia (EDS) e por calorimetria exploratória diferencial (DSC) sugerem uma perda maior de níquel que titânio. No processo de Alimentação Contínua e Lingotamento Estático, a perda de peso variou de 0,5 a 1,2%, dependendo da corrente do feixe de elétrons. No processo de Fusão Estática, as temperaturas de pico da transformação martensítica (Mp) foram comparadas com a curva de referência, e indica que a composição química varia de 50,3 a 50,8%at. de níquel ao longo do comprimento da amostra. Isto também mostra que a produção da liga Ni-Ti com EMF é perfeitamente possível desde que tomados alguns cuidados.
220

Propriedades de efeito de memória de forma e superelasticidade da liga niti com distintos teores de carbono e oxigênio.

Osmar de Sousa Santos 30 June 2014 (has links)
Pequenas amostras refundidas em forma de botões em forno de feixe de elétrons com alta taxa de resfriamento aumentam as temperaturas de transformação martensítica direta e reversa pelo fato de manterem boa parte do carbono e oxigênio em solução e também devido a possível evaporação do níquel. De uma maneira geral, o aumento da resistência mecânica é promovido pela precipitação de Ti4Ni2O, TiC e Ti3Ni4. A análise separando a recuperação superelástica total, RSET, em dois componentes, a recuperação superelástica propriamente dita, RSE, e a recuperação elástica convencional, REL, é inédita. Verificou-se que quando a resistência mecânica da matriz é alta, o componente superelástico aumenta com o número de ciclos e o componente da recuperação elástica decresce na mesma situação. Amostra com baixo teor de carbono apresenta recuperação superelástica, RSET, de 100% até 8% de deformação enquanto que a medida que se aumenta o teor de carbono, a mesma propriedade decresce com o aumento da deformação ou com o número de ciclos. O uso da máquina Gleeble acoplada a uma linha de difração de raios X com possibilidade de aquecimento é um trabalho inédito em ligas com efeito de memória de forma. Observou-se que o tratamento a 400 C apresentou melhor resultado em termos de recuperação superelástica e através do ensaio acima pôde se identificar as fases presentes e a evolução dos mesmos nos ciclos de deformação.

Page generated in 0.0566 seconds