Spelling suggestions: "subject:"peixe""
351 |
Caracterização mecânica e microestrutural do aço API 5L - X65 soldado por feixe de elétrons / Mechanical and microstructural characterization of API 5L - X65 steel welded by electron beamFilipe Corrêa Pinto 09 August 2011 (has links)
O objetivo deste trabalho é a caracterização mecânica e microestrutural do aço API 5L-X65 soldado por feixe de elétrons para possível aplicação no processo de fabricação de dutos para o transporte de óleo e gás. A caracterização do material será realizada por meio de microscopia ótica, análise de textura via difração de raios X, microdureza Vickers e ensaio Charpy V. Para a caracterização microestrutural, foram testados diferentes ataques químicos para a identificação das fases presentes na microestrutura de cada uma das três regiões que compõem uma junta soldada, zona fundida (ZF), zona termicamente afetada (ZTA) e o metal base (MB). As microestruturas das regiões que foram submetidas ao ciclo térmico de soldagem, apresentaram-se bastante distintas da microestrutura bandeada ferrítico-perlítica encontrada no MB. A ZTA apresentou uma estrutura de grãos refinados, as bandas perlíticas do MB se tornaram completamente difusas, não mantendo qualquer semelhança com a microestrutura perlítica anterior e também, foram evidenciadas ilhas do constituinte M-A (martensita-austenita). Na ZF foram evidenciadas as fases tipicamente encontradas em metais de solda de aços microligados, tais como: ferrita de Widmanstätten, acicular, alotriomórfica, além de bainita e ilhas do constituinte M-A. Os resultados das propriedades mecânicas do material submetido ao processo de soldagem por EBW foram satisfatórios e atendem os requisitos da Norma API 5L. Desta forma, de acordo com os resultados obtidos neste trabalho é possível a aplicação da soldagem por EBW na fabricação e montagem de sistemas de dutos. / The aim of this work is the mechanical and microstructural characterization of API 5L-X65 steel welds performed by electron beam welding, as well as to investigate the technical feasibility of applying this welding process in the manufacture and assembly of pipelines for oil and gas. The characterization was carried out by using light optical microscopy, X-ray diffraction texture analysis, Vickers micro-hardness testing and tests Charpy V. For the microstructural characterization, several chemical etchants were tested in order to identify the phases present in the microstructure of the regions associated to the weld, i.e. the weld metal (WM), the heat affected zone (HAZ) and the base metal (BM). The microstructures of the regions exposed to thermal welding cycles displayed quite distinct microstructure than the one found in the BM (banded ferritic-pearlitic structure). The HAZ showed a refined grain structure where the pearlite bands of BM became quite diffuse. Islands of the M-A (martensite-austenite) constituent were found in the HAZ. The phases typically found in weld metals of microalloyed steels such as Widmanstätten ferrite, acicular ferrite, allotriomorphic ferrite, bainite, and M-A constituent were found in the WM. The results of the mechanical properties of the material submitted to the welding process by EBW were satisfactory and meet the requirements of the standard API 5L. Thus, the according to the results obtained in this work is possible the application of EBW in the manufacture and assembly of pipeline systems.
|
352 |
Validade da tomografia computadorizada multislice e da tomografia computadorizada por feixe cônico para identificação de lesões ósseas simuladas na mandíbula, com e sem a presença de artefatos dentários metálicos / Validity of multislice computed tomography and cone-beam computed tomography for the identification of bone lesions in the mandible with and without dental metal artifacts the presence of dental metallic artifactsAndréia Perrella 02 December 2009 (has links)
O propósito deste estudo foi avaliar a acurácia do exame de tomografia computadorizada multislice (TCM) e tomografia computadorizada por feixe cônico (TCFC) na identificação de lesões simuladas em mandíbula, em situações com e sem a presença de artefatos metálicos, em diversos protocolos de observação. Foram realizados exames de TCM e TCFC de mandíbulas secas, nas quais foram executadas perfurações simulando lesões. As imagens foram realizadas em dois momentos: na presença e na ausência de restaurações dentárias metálicas. Dois observadores, previamente calibrados, observaram as imagens avaliando-as quanto à presença ou ausência de lesão, número de lojas das lesões e a existência ou não de invasão medular. Os mesmos utilizaram programas de manipulação de imagens instalados em estações de trabalho independentes, para reconstruir as imagens nos seguintes protocolos de avaliação: axial, sagital + coronal, 3D, conjunto (axial+sagital+coronal+3D) e parassagital. A sensibilidade e especificidade (validade) da tomografia computadorizada multislice (64 cortes) (TCM) e da tomografia computadorizada por feixe cônico (TCFC) para diagnóstico de lesões ósseas (simuladas) em mandíbula, utilizando estação de trabalho independente foram demonstradas à medida que os valores encontrados foram superiores a 95% desde que com o protocolo de observação adequado. A influência de artefatos dentários metálicos foi pouco significativa na interpretação de lesões ósseas mandibulares, já que os valores de acurácia nas análises com e sem artefato foram bastante próximas. Os protocolos com aquisição por TCM sofreram mais influência dos artefatos do que os adquiridos por TCFC (valores sutilmente menores), exceto nas reconstruções em 3D, em que as originadas de aquisição por TCFC, apresentaram valores menores de acurácia. O melhor protocolo de pós processamento para interpretação de lesões ósseas simuladas foi o denominado RMP+3D. O protocolo que apresentou os piores resultados foi o que utilizou as reconstruções parassagitais. / The purpose of this study was to evaluate the accuracy of multislice computed tomography (MSCT) and cone-beam computed tomography (CBCT) in identification of simulated mandibular lesions in situations with and without metallic artifacts in several observation protocols. MSCT and CBCT examinations were performed in dry mandibles, in which holes were performed simulating lesions. The images were taken in two stages: in the presence and absence of metal dental restorations. Two observers, previously calibrated, observed the images by evaluating the images for the presence or absence of lesion, loci number and whether there were medullary invasion. Observers used image manipulation softwares, installed on independent workstations, to reconstruct the images in the following evaluation protocols: axial, sagittal + coronal, 3D, sets (axial+ coronal + sagittal + 3 D) and parasagittal. The sensitivity and specificity of MSCT (64 slices) and CBCT for diagnosis of simulated bone lesions in the mandible, using independent workstation were demonstrated as the values obtained were greater than 95% using the appropriate observation protocol. The influence of dental metallic artifacts was negligible in the interpretation of mandibular bone lesions, since the values of accuracy in the analysis with and without artifact were quite close. The images acquired with MCT suffered more influence of artifacts than the protocols acquired by TCFC, although the values were all high and quite close. Except for 3D reconstructions, which originated from the CBCT, showed the lowest accuracy. The best protocol for post-processing and interpretation of simulated bone lesions was called RMP +3 D. The protocol that showed the worst results was parasagital.
|
353 |
Comparação das alterações dimensionais do rebordo alveolar pós-exodontia entre a técnica de preservação alveolar com a utilização de substituto ósseo xenógeno e a cicatrização espontânea: ensaio clínico aleatório / Comparison of dimensional alterations of the post-extraction socket between the alveolar preservation technique with the use of xenogenic bone substitute and spontaneous healing: randomized clinical trialLlanos, Alexandre Hugo 29 January 2018 (has links)
A cicatrização de um alvéolo após a extração dental é uma resposta reparadora. Após a exodontia, a cicatrização espontânea irá levar à perda do volume e do formato do rebordo original. A preservação alveolar envolve qualquer procedimento que limite os efeitos da reabsorção pós-extração. O objetivo deste estudo foi avaliar o uso de um substituto ósseo xenogênico na preservação alveolar pós-extração dental comparado com a cicatrização espontânea em dentes anteriores da maxila com defeitos ósseos da parede vestibular maiores do que 50%. Foram tratados 13 pacientes com necessidade de exodontia de dente anterior da maxila com perda >50% da parede vestibular. Todas as exodontias foram realizadas sem retalho. Os pacientes foram alocados aleatoriamente em grupo teste: preservação alveolar com substituto ósseo (7 participantes) e grupo controle: cicatrização espontânea (6 participantes). O desfecho primário foi a alteração dimensional do rebordo alveolar calculada entre as imagens tomográficas de início (pós-exodontia) e depois de 4 meses da intervenção, na espessura 1mm abaixo da porção coronal da crista (HW-1). Os desfechos secundários foram as medidas vestibular e palatina, e os segmentos transversais HW-3 e HW-5. A medida HW-1 reduziu 51,21 % no grupo teste e 82,80% no grupo controle, com uma diferença intergrupos estatisticamente significante de 31,59%. Para as medidas transversais, houve redução estatisticamente significante tanto para HW-3 quanto para HW-5 entre os dois grupos. Em alvéolos com perda da parede vestibular maior que 50%, a utilização do substituto ósseo promoveu uma menor perda horizontal na ordem de 30%. / The healing process of post-extraction sockets is bone resorption. After tooth extraction, spontaneous healing will lead to loss of volume and shape of the original ridge. Alveolar ridge preservation involves any procedure that limits the effects of post-extraction resorption. The objective of this study was to evaluate the use of the xenogenic bone substitute in the post-extraction alveolar preservation compared to spontaneous healing in anterior maxilla teeth with vestibular wall defects greater than 50%. Thirteen patients with anterior maxillary tooth extraction with a > 50% buccal wall loss were treated. All the surgeries were made flapless. Patients were randomly assigned to a test group: alveolar preservation with bone substitute (7 participants); and control group: spontaneous healing (6 participants). The primary outcome was the dimensional alteration of the alveolar ridge calculated between the tomographic images at the beginning (post-extraction) and after 4 months of the intervention, at the thickness 1mm below the coronal portion of the crest (HW-1). Secondary outcomes were measures buccal and palatine, and HW-3 and HW-5 cross-sections. The HW-1 measure reduced 51.21% in the test group and 82.80% in the control group, with a statistically significant intergroup difference of 31.59%. For the other horizontal measurements, there was a statistically significant reduction for both HW-3 and HW-5 between the two groups. In sockets with buccal wall loss greater than 50%, the use of the bone substitute provided a 30% lower horizontal loss.
|
354 |
Algoritmo do volume e otimização não diferenciável / \"Volume Algorithm and Nondifferentiable Optimization\"Fukuda, Ellen Hidemi 01 March 2007 (has links)
Uma maneira de resolver problemas de programação linear de grande escala é explorar a relaxação lagrangeana das restrições \"difíceis\'\' e utilizar métodos de subgradientes. Populares por fornecerem rapidamente boas aproximações de soluções duais, eles não produzem diretamente as soluções primais. Para obtê-las com custo computacional adequado, pode-se construir seqüências ergódicas ou utilizar uma técnica proposta recentemente, denominada algoritmo do volume. As propriedades teóricas de convergência não foram bem estabelecidas nesse algoritmo, mas pequenas modificações permitem a demonstração da convergência dual. Destacam-se como adaptações o algoritmo do volume revisado, um método de feixes específico, e o algoritmo do volume incorporado ao método de variação do alvo. Este trabalho foi baseado no estudo desses algoritmos e de todos os conceitos envolvidos, em especial, análise convexa e otimização não diferenciável. Estudamos as principais diferenças teóricas desses métodos e realizamos comparações numéricas com problemas lineares e lineares inteiros, em particular, o corte máximo em grafos. / One way to solve large-scale linear programming problems is to exploit the Lagrangian relaxation of the difficult constraints and use subgradient methods. Such methods are popular as they give good approximations of dual solutions. Unfortunately, they do not directly yield primal solutions. Two alternatives to obtain primal solutions under reasonable computational cost are the construction of ergodic sequences and the use of the recently developed volume algorithm. While the convergence of ergodic sequences is well understood, the convergence properties of the volume algorithm is not well established in the original paper. This lead to some modifications of the original method to ease the proof of dual convergence. Three alternatives are the revised volume algorithm, a special case of the bundle method, and the volume algorithm incorporated by the variable target value method. The aim of this work is to study such algorithms and all related concepts, especially convex analysis and nondifferentiable optimization. We analysed the main theoretical differences among the methods and performed numerical experiments with linear and integer problems, in particular, the maximum cut problem on graphs.
|
355 |
Método da propagação de feixe de ângulo largo para análise de guias de ondas ópticos não-lineares / not availableFlamino, Reinaldo de Sales 21 September 2001 (has links)
Este trabalho propõe uma extensão do método de propagação de feixe (BPM - Beam Propagation Method) para a análise de guias de ondas ópticos e acopladores baseados em materiais não-lineares do tipo Kerr. Este método se destina à investigação de estruturas onde a utilização da equação escalar de Helmholtz (EEH) em seu limite paraxial não mais se aplica. Os métodos desenvolvidos para este fim são denominados na literatura como métodos de propagação de feixe de ângulo largo. O formalismo aqui desenvolvido é baseado na técnica das diferenças finitas e nos esquemas de Crank-Nicholson (CN) e Douglas generalizado (GD). Estes esquemas apresentam como característica o fato de apresentarem um erro de truncamento em relação ao passo de discretização transversal, Δx, proporcional a O(Δx2) para o primeiro e O(Δx4). A convergência do método em ambos esquemas é otimizada pela utilização de um algoritmo interativo para a correção do campo no meio não-linear. O formalismo de ângulo largo é obtido pela expansão da EEH para os esquemas CN e GD em termos de polinômios aproximantes de Padé de ordem (1,0) e (1,1) para CN e GD, e (2,2) e (3,3) para CN. Os aproximantes de ordem superior a (1,1) apresentam sérios problemas de estabilidade. Este problema é eliminado pela rotação dos aproximantes no plano complexo. Duas condições de contorno nos extremos da janela computacional são também investigadas: 1) (TBC - Transparent Boundary Condition) e 2) condição de contorno absorvente (TAB - Transparent Absorbing Boundary). Estas condições de contorno possuem a facilidade de evitar que reflexões indesejáveis sejam transmitidas para dentro da janela computacional. Um estudo comparativo da influência destas condições de contorno na solução de guias de ondas ópticos não-lineares é também abordada neste trabalho. / This work introduces an extension of the beam propagation method (BPM) for the analysis of optical waveguides and couplers based on Kerr-type nonlinear materials. This method is intended for the investigation of structures where the paraxial scalar Helmholtz equation (EEH) no longer holds. The numerical methods developed for this situation are known in the literature as wide-angle beam propagation methods. The formulation developed in this work is based on finite differences and on the Crank-Nicholson (CN) and Generalized Douglas (GD) schemes. These schemes are characterized by a truncation error with respect to the transverse discretization step, Δx, proporcional to O(Δx2) for the CN and to O(Δx4) for the GD scheme. The convergence of the method for both schemes is optimized by the application of an iterative algorithm for the correction of the field in the nonlinear medium. The wide-angle formalism is obtained by the expansion of the EEH for the CN and GD schemes in terms of Padé approximant polynomials. The expansions addressed in this work utilize Padé approximants of order (1,0) and (1,1) for the CN and GD scheme, and (2,2) and (3,3) for the CN scheme. Approximants orders higher than (1,1) show serious stability problems. This problem is circumvented by rotating the approximants in the complex plane. Two boundary conditions on the edge of the computational window are also investigated: 1) transparent boundary condition (TBC) and 2) transparent absorbing boundary (TAB). These boundary conditions are necessary in order to avoid unwanted reflections back to computational domain. A comparative study of the influence of these boundary conditions on the solution of nonlinear optical waveguides is also addressed in this work.
|
356 |
Comparação da morfometria da base de crânio de indivíduos com fissura labiopalatal e indivíduos com ou sem discrepância maxilo-mandibular / Morphometric comparison of the base of the skull of patients with cleft lip and palate and patients with or without skeletal discrepancyLima, Ana Paula da Cunha Barbosa de 01 November 2017 (has links)
Objetivo: O objetivo deste trabalho foi verificar a existência de variações da morfometria de base de crânio entre indivíduos com fissura labiopalatal, com deformidade dentofacial e sem deformidade dentofacial, grupo controle. Metodologia: Três grupos de indivíduos, um grupo com deformidade dentofacial sem associação com fissura labiopalatal (DFSF), outro com fissura labiopalatal (FS), e outro grupo de pacientes sem fissura e sem deformidade (CTRL - Controle), foram elencados por meio de registros de prontuários e de imagens em DICOM (Digital Imaging Communications in Medicine) de suas tomografias computadorizadas. Por meio da identificação dos pontos cefalométricos basio (Ba), sela (S) e nasio (N), no software Dolphin Imaging 11.9, obteve-se a distância entre os pontos Ba-S (DBaS), S-N (DSN) bem como o ângulo formado entre os pontos Ba-S-N (AnGBaSN). As variáveis cefalométricas em questão foram avaliadas considerando (p<0,05). Resultados: Vinte indivíduos compuseram cada um dos grupos. Verificamos que a distância S-N (DSN) não apresentou diferença estatística entre os grupos, mas a distância Ba-S (DBaS) e o ângulo Ba-S-N (AnGBaSN) apresentaram diferenças estatísticas quando comparados os três grupos. O ângulo Ba-S-N (AnGBaSN) não apresentou diferença estatística quando comparados o grupo controle (CTRL) e o grupo de pacientes portadores de fissura labiopalatal (FS), mas apresentou diferença estatística em relação ao do grupo de pacientes com deformidades faciais sem fissuras labiopalatais (DFSF). A distância BaS (DBaS) apresentou diferença estatística entre o grupo de pacientes portadores de fissuras (FS) em relação aos outros dois grupos. Conclusão: Diferenças na morfometria da base de crânio entre indivíduos com deformidade dentofacial associada ou não a fissuras labiopalatais sugerem que valores padronizados para análises cefalométricas que envolvam tais estruturas sejam usadas com cautela. Novos padrões cefalométricos, em especial por análise 3D, são desejáveis para compensação dessas diferenças anatômicas. / Objective: The aim of this study was to verify the existence of variations of the skull base morphometry between patients with cleft lip and palate, with dentofacial deformity group and without dentofacial deformity (control group). Methodology: Three groups of patients, one group with dentofacial deformity associated without cleft lip and palate (DFSF), another with cleft lip and palate (FS), and another group of patients without cleft and without deformity (CTRL) were included by means of medical records and DICOM (Digital Imaging Communications in Medicine) images of their CT (Computed Tomography) scans. By identifying the basio (Ba), sela (S) and nasio (N) cephalometric points in the Dolphin Imaging 11.9 software, the distance between the points Ba-S (DBaS), S-N(DSN) and the angle formed between points Ba-S-N (AnGBaSN) were the variables. They were statistically evaluated by means of the p> 0.05. Results: Twenty patients were included on each group. We found that the distance S-N (DSN) is not statistically different between the groups, but the Ba-S distance (DBaS) and the Ba-S-N angle (AnGBaSN) are statistically different when compared the three groups. The Ba-S-N angle (AnGBaSN) did not present statistically different when compared to the control group (CTRL) and the group cleft lip and palate patients (FS), but presented statistical difference in relation to the group of patients with facial deformities without cleft lip and palate (DFSF). The distance BaS (DBaS) presented statistical difference between the group of patients with fissures (FS) in relation to the other two groups. Conclusion: Differences in skull base morphometry among patients with dentofacial deformity associated or not with cleft lip and palate suggest that standardized values for cephalometric analyzes involving such structures should be used with caution. New cephalometric patterns, especially by 3D analysis, are desirable to compensate for these anatomical differences.
|
357 |
Avaliação craniofacial em síndrome de AspergerFerreira, Carla Regina Mauad de Paula 18 April 2012 (has links)
Made available in DSpace on 2016-01-26T12:51:49Z (GMT). No. of bitstreams: 1
carlareginamauadpaulaferreira_dissert.pdf: 1381182 bytes, checksum: 451c7414572128b78ae46256c72b0453 (MD5)
Previous issue date: 2012-04-18 / The Asperger Syndrome (AS) is one of the conditions that make up the autism spectrum disorders, which are part of a group of severe psychiatric disorders are common in the general population and complex, called Pervasive Developmental Disorders. This syndrome is characterized by qualitative impairments in social interaction and restricted patterns of interest, however, there is no delay in language acquisition, speech is often pragmatic and memory is prodigious. Although most studied in neurological and behavioral context, the craniofacial phenotype is unclear. The objective of this study was to investigate the cephalometric measurements for Cone Beam Computed Tomography in patients with SA, for investigation of craniofacial changes, even that may influence the masticatory and respiratory functions. Measurements were carried out craniofacial cephalometrics obtained by 3D measurement of head circumference and facial and intraoral photographs of 10 individuals with AS, which were compared with a control group comprising 10 individuals of the same sex and age. The measurements obtained were compared with standard 2D measures already in place. There were no occlusal problems, facial features or specific phenotypic abnormalities in the group with AS. Individuals with AS had more difficulty chewing hard foods. Anatomical changes in the airways, characterized as septal deviations, turbinate hypertrophy and obstruction of the frontal and maxillary sinuses were more frequent in individuals with AS. These findings may be characteristic of AS and justify the difficulty of nasal breathing and chewing reported by the group. / A Síndrome de Asperger (SA) é uma das afecções que compõem as Doenças do Espectro Autístico, que fazem parte de um grupo de doenças psiquiátricas graves, comuns na população em geral e complexas, denominado Transtornos Invasivos do Desenvolvimento. Tal síndrome se caracteriza por prejuízos qualitativos na interação social e padrões restritos de interesses, porém, não há atraso na aquisição da linguagem, a fala é pragmática e a memória muitas vezes é prodigiosa. Embora seja mais estudada no contexto neurológico e comportamental, o fenótipo crâniofacial não está esclarecido. O objetivo deste estudo foi investigar medidas cefalométricas por Tomografia Computadorizada por Feixe Cônico, em pacientes com SA, para investigação de alterações craniofaciais, inclusive, que possam influenciar as funções mastigatórias e respiratórias. Foram realizadas medidas crâniofaciais obtidas por cefalometria 3D, medida do perímetro cefálico e fotografias de face e intraorais, de 10 indivíduos com SA, que foram comparadas com as um grupo controle composto de 10 indivíduos de mesmo sexo e idade. As medidas obtidas foram comparadas com medidas padrões 2D já estabelecidas. Não foram observados problemas oclusais, características ou anormalidades fenotípicas faciais específicas do grupo com SA. Os indivíduos com SA apresentaram mais dificuldade de mastigação de alimentos duros. Alterações anatômicas nas vias aéreas, caracterizadas como desvios de septo, conchas nasais hipertrofiadas e obstrução de seios maxilares e frontais, foram mais frequentes em indivíduos com SA. Estes achados podem ser característicos de SA e justificar a dificuldade de respiração nasal e de mastigação relatadas pelo grupo estudado.
|
358 |
Estudos dos parâmetros de deformação dos isótopos 24Mg, 30Mg e 32Mg / Studies of the deformation parameters of the isotopes 24mg, 30mg and 32MgChisté, Vanessa 06 October 1999 (has links)
A proposta deste trabalho é estudar as distribuições de prótons e nêutrons e suas deformações na região da \"ilha de inversão\". Esta região, situada entre 10 Z 14 e 19 N 21, apresentar anomalias como núcleos fortemente deformados perto do número mágico N=20. Os parâmetros de deformação de carga e de matéria dos isótopos de 24Mg, 30Mg e 32Mg foram medidos, via espalhamento inelástico do feixe secundário de Mg, através de um experimento realizado no Laboratório GANIL, Caen, França. Um feixe primário de 36S, a 77 MeV/núcleon, produziu, via fragmentação do projétil sobre um alvo de 12C, feixes secundários de 24, 30,32Mg, com 37 MeV/núcleon. O feixe secundário foi analisado nos dipolos acromáticos do espectrômetro LISE. Os parâmetros de deformação são extraídos da seção de choque de excitação do projétil de Mg para o seu primeiro estado 2+. Para medir a distribuição de carga, um alvo de 208Pb foi utilizado. Como a interação nuclear e mais forte com o 12C, este alvo foi utilizado para determinar a deformação de massa. A obtenção dos parâmetros de deformação foi feita através da comparação da são de choque experimental com a seção de choque calculada através do formalismo de canais acoplados (programa ECIS) Na comparação, determinou-se a deformação nuclear e coulombiana do 24Mg, muito próxima dos valores adotados. Para o 30Mg, obtiveram-se parâmetros de deformação coulombiano e nuclear semelhantes e grandes, mostrando que este núcleo também e fortemente deformado. No caso do 32Mg, que tem atraído muito interesse devido a possível perda de magicidade, ob-teve-se que ele e mais deformado do que previsto pelos vários cálculos teóricos feitos ate estão, apresentando também deformações de carga e massa iguais. / The goal of this work is the study of the proton and neutron distributions and their deformations in the region of the island of inversion\". This region is situated between 10 Z 14 and 19 N 21and the neutron-rich nuclei of this \"island\" have an anomalus behaviour, being strongly deformed at the nentron magic number N=20. The charge and matter deformation parameters of 24Mg 30Mg e 32Mg were measured in an experiment realized at the GANIL Labo-ratory, Caen, Francel through the inelastic scattering the Mg secondary beams . The 36S pri-mary beam at 77 MeV/nucleon produced the 24,30,32Mg secondary at 37 MeV/nucleon through projectile fragmentation on a 12C production target. The secondary beam was analysed in the LISE spectrometer. The deformation parameters were extracted from the cross section of the Mg projectile to its 2+ first excited state. A 208Pb target was used to measure the Coulomb de-formation and a 12C target for the nuclear deformation. The deformation parameters were obtained from the comparision between the experimental excitation cross sedion and the calculated through a coupled channels code ECIS. The Coulomb and nuclear deformation pa-rameters of the 24Mg determined in this study are very close to the adopted values. The deformation parameters of 30Mg are large and nearly equal, showing tha.t this nucleus is also strongly deformed. For the 32Mg, which has lately attracted much attention, the deformation parameters are much larger than predicted by theoretical models and are also equal.
|
359 |
Avaliação da estabilidade da cirurgia de avanço mandibular através da superposição de modelos tridimensionais / Three-dimensional assessment of mandibular advancement 1 year after surgeryFelipe de Assis Ribeiro Carvalho 12 August 2009 (has links)
Embora a cirurgia de avanço mandibular seja considerada um procedimento altamente estável, existem algumas preocupações clínicas em relação a mudanças nos côndilos e nos segmentos proximais, que podem levar a recidiva sagital e abertura de mordida. A avaliação dos resultados da cirurgia através de ferramentas de geração e superposição de modelos virtuais tridimensionais (3D) permite a identificação e quantificação dos deslocamentos e remodelação óssea que podem ajudar a explicar as interações entre os componentes dentários, esqueléticos e de tecido mole que estão relacionados a resposta ao tratamento. Este estudo observacional prospectivo avaliou, através de tomografia computadorizada de feixe cônico (CBCT), mudanças na posição/remodelação 3D dos ramos mandibulares, côndilos e mento. Assim, exames CBCT de 27 pacientes foram adquiridos antes da cirurgia (T1), imediatamente após a cirurgia(T2), e 1 ano após a cirurgia(T3). Uma técnica automática de superposição na base do crânio foi utilizada para permitir a avaliação das mudanças ocorridas nas regiões anatômicas de interesse (RAI). Os deslocamentos foram visualizados e quantificados em mapas coloridos 3D através da ferramenta de linha de contorno (ISOLINE). Pelo teste t pareado compararam-se as mudanças entre T1-T2 e T2-T3. O coeficiente de correlação de Pearson verificou se os deslocamentos ocorridos nas RAI foram correlacionados entre si e entre os tempos de avaliação. O nível de significância foi determinado em 0,05. O avanço mandibular médio foi de 6,813,2mm em T2 e 6,363,41mm em T3 (p=0,13). Entre T2 e T3, a posição do mento variou positivamente (≥2mm) em 5 pacientes negativamente em 7. 12% dos pacientes sofreram recidivas ≥4mm. Para todas as outras RAI avaliadas, apenas a porção inferior dos ramos (lado direito - 2,342,35mm e lado esquerdo 2,972,71mm) sofreram deslocamentos médios >2mm com a cirurgia. No acompanhamento em longo prazo, esse deslocamento lateral da porção inferior dos ramos foi mantido (lado direito - 2,102,15mm, p=0,26; e lado esquerdo -2,762,80, p=0,46), bem como todos os outros deslocamentos observados (p>0,05). As mudanças na posição do mento foram correlacionadas a adaptações pós-cirúrgicas nos bordos posteriores dos ramos (esquerdo r=-0,73 e direito r=-0,68) e côndilos (esquerdo r=-0,53 e direito r=-0,46). Os deslocamentos médios sofridos pelas estruturas do lado esquerdo foram suavemente maiores do que no direito. Correlações dos deslocamentos ocorridos entre T1-T2 e T2-T3 mostraram que: os deslocamentos dos côndilos esquerdos com a cirurgia foram negativamente correlacionados às adaptações pós-cirúrgicas destes (r=-0,51); e que o deslocamento da porção superior do ramo esquerdo com a cirurgia foi correlacionado à adaptação pós-cirúrgica ocorrida nos bordos posteriores (r=0,39) e côndilos do mesmo lado (r=0,39). Pode-se concluir que: (1) os deslocamentos causados pela cirurgia foram de modo geral estáveis no acompanhamento de 1 ano, mas identificou-se uma considerável variação individual; (2) as mudanças pós-cirúrgicas na posição do mento foram correlacionadas a adaptações sofridas pelos côndilos e bordos posteriores dos ramos; e que (3) deslocamentos suavemente maiores causados pela cirurgia nas estruturas do lado esquerdo levaram a maiores adaptações pós-cirúrgicas no segmento proximal deste lado. / Although mandibular advancement surgery is considered a highly stable procedure, some clinical concerns have been raised regarding condylar and proximal segment changes that may lead to sagittal relapse and anterior bite opening. Assessment of surgical treatment outcomes using three-dimensional (3D) virtual models and superimposition tools allow the identification and quantification of bone displacement and remodeling that can help explain the interactions between the dental, skeletal and soft tissue components that underpin the response to treatment. This prospective observational study evaluated changes in the 3D position and remodeling of the mandibular rami, condyles and chin at splint-removal and 1 year after mandibular advancement surgery. For that, pre-surgery(T1), splint-removal(T2), and one year post-surgery(T3) cone-beam computed tomography (CBCT) scans of 27 subjects were used. An automatic technique of cranial base superimposition was used to assess changes in the anatomic regions of interest (ROI). Displacements were visually displayed and quantified in three-dimensional color maps by means of a contour line tool (ISOLINE). A paired t-test was used to compare changes between T1-T2 and T2-T3. Pearson correlation coefficients were used to check if displacements at the ROI were correlated within each other and along the evaluated times . The level of significance was set at 0.05. The mean mandibular advancement was 6.813.2mm at T2 and 6.363.41mm at T3 (p =0.13). Between T2 and T3, the chin position was further forward 2mm or more for 5 subjects and relapsed backwards ≥2mm for 7 subjects. 12% of patients showed relapses ≥4mm. For all other evaluated ROI, only the inferior rami (right 2.342.35mm and left 2.972.71mm) had mean displacements >2mm with surgery. In the long-term follow-up, those inferior rami lateral displacements were maintained (right 2.102.15mm, p=0.26 and left 2.762.80,p=0.46), as well as all other observed displacements (p>0.05). Post-surgical movement in the position of the chin was significantly correlated to changes in the posterior borders (left r=-0.73 and right r=-0.68) and condyles (left r=-0.53 and right r=-0.46). Mean displacements of the structures at the left side were slightly greater when comparing to the right side. Correlations of T1-T2 with T2-T3 displacements showed that the displacement of the left condyles with surgery were negatively correlated to its post-surgical adaptations (r=-0.51); and that superior portion of the left ramus surgery displacement was correlated to the post-surgical adaptation at the ramus posterior border (r=0.39) and condyle at the same side (r=0.39). It can be concluded that: (1) surgery changes were generally stable in one year follow up, but with a considerable individual variability; (2) post-surgical changes at the chin position are correlated to adaptations at condyles and rami posterior borders; and that (3) slightly greater displacements with surgery at the left side lead to greater post-surgical adaptations in the proximal segment at this side.
|
360 |
Tomografia computadorizada por feixe cônico para identificação de defeitos ósseos peri-implantares quimicamente simulados em costelas bovinas frescas / Cone beam computed tomography for identification of peri-implant bone loss chemically simulated in fresh bovine ribsLucas Rodrigues Pinheiro 12 March 2015 (has links)
O objetivo deste estudo foi avaliar a acurácia, sensibilidade, especificidade e concordância inter e intra-observador dos exames radiográficos: radiografia periapical digital indireta (RP) por meio de placas de fósforo e tomografia computadorizada por feixe cônico (TCFC) na detecção de defeitos ósseos peri-implantares quimicamente simulados com Ácido Perclórico a 70%. 80 implantes foram instalados em blocos de costela bovina. Os implantes foram divididos em 2 grupos (grupo controle e grupo teste), em seguida o grupo teste foi dividido em 2 subgrupos (G1 e G2). O grupo G1 foi exposto a 4h de ácido causando defeitos de aproximadamente 3-4 mm de profundidade e largura <=1 mm, enquanto o grupo G2 foi exposto a 12h . Posteriormente, as amostras foram submetidas a um sistema de Radiografia digital indireta por meio de placa de fósforo (CS 7600) e a dois diferentes tomógrafos, utilizando variados protocolos (iCAT Next Generation e 3D Accuitomo 170). Os observadores avaliaram as imagens em um programa de visualização independente (OsiriX MD) utilizando a ferramenta a 3D-RMP que permite explorar cortes axiais, coronais, sagitais, parassagitais e circunferenciais simultaneamente. Nas amostras avaliadas por radiografia periapical, os valores da ASC encontrados nas amostras com defeitos ósseo menores variaram entre 0,442 a 0,534; no iCAT Next Generantion, variaram entre 0,645 a 0.828 em dois protocolos diferente. No 3D Accuitomo 170, variaram entre 0.563 a 0.904, em protocolos diferentes. No grupo com defeito ósseos maiores os resultados foram superiores. Na radiografia periapical, os valores encontrados variaram entre 0,652 a 0,771; no iCAT Next Generation, variaram entre 0,708 a 0,946 em dois protocolos diferentes e no 3D Accuitomo 170, entre 0.628 a 0.962 em 4 protocolos diferentes. A radiografia periapical foi a modalidade testada que obteve pior desempenho, especialmente no grupo de lesões menores. O protocolo de 90 kVp, FOV 4x4 cm e 1009 projeções de raios-X do 3D Accuitomo 170 foi o que obteve os valores de diagnóstico mais altos. A TCFC obteve resultados mais satisfatórios que a RP para a detecção de defeitos ósseos peri-implantares. Porém o uso da TCFC deve ser cauteloso e criterioso na hora da escolha do protocolo de aquisição adequado para cada situação. / The aim of this study was to test the accuracy, sensitivity, specificity, inter and intra-observer and area AZ values of two radiographic examinations: digital periapical radiographs and cone beam computed tomography (CBCT) in the detection of two sizes of peri-implant bone defects chemically simulated with Perchloric Acid 70%. PR and CBCT were performed in 80 dental implants installed in blocks of bovine rib. An indirect digital radiography system using smart phosphor plates (CS 7600) and two different CBCT scanners, using different protocols (iCAT Next Generation 3D Accuitomo 170) were evaluated. Observers evaluated the images in a separate DICOM viewer (OsiriX MD) using the 3D-RMP tool. This tool allows the visualization of axial, coronal, sagittal, cross-section and circumferential images. In samples evaluated by periapical radiography, the AZ values found in the samples with smaller bone defects ranged from 0.442 to 0.534; in iCAT Next Generantion, ranged from 0.645 to 0.828 in two different protocols. In 3D Accuitomo 170, ranged 0.563-0.904 in four different protocols. In the group with larger bone defect results were superior. In periapical, the values found ranged from 0.652 to 0.771; iCAT the Next Generation ranged from 0.708 to 0.946 in two different protocols and 3D Accuitomo 170, 0.628-0.962 in 4 different protocols. Periapical radiographs were tested method that had a worse performance, especially in the smaller lesions group. The protocol FOV 4x4 cm and 1009 frames of 3D Accuitomo 170 had the highest diagnostic values. The CBCT proved to be a useful imaging modality for detecting the peri-implant bone defects, with better results than PR. But the use of CBCT should be cautious and careful when choosing the acquisition protocol appropriate for each situation.
|
Page generated in 0.0484 seconds