• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 42
  • 9
  • 1
  • Tagged with
  • 52
  • 27
  • 25
  • 21
  • 20
  • 16
  • 15
  • 15
  • 15
  • 14
  • 11
  • 10
  • 9
  • 9
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Dispositifs expérimentaux pour la caractérisation spatio-temporelle de chaines laser femtosecondes haute-puissance / Experimental devices for the spatiotemporal characterization of femtosecond high-power laser chains

Gallet, Valentin 26 September 2014 (has links)
Un des avantages des lasers femtosecondes de haute puissance (TW-PW) est de pouvoir obtenir, au foyer d'une optique focalisante, des intensités très élevées atteignant jusqu'à 10^22W.cm^-2 soit un champ électrique de 2.7 PV.m^-1. Pour cela, ces chaînes lasers délivrent nécessairement des faisceaux de grands diamètres (jusqu'à 40 cm) et des impulsions très courtes (de l'ordre de la dizaine de femtosecondes). En conséquence, les propriétés spatiales et temporelles de l'impulsion ne sont généralement pas indépendantes. Ce type de dépendance, appelée couplage spatio-temporel, a pour conséquence d'augmenter la durée d'impulsion et la taille de la tache focale, ce qui peut conduire à une diminution notable de l'intensité maximale au foyer. Les dispositifs de métrologie couramment utilisés sur ces chaînes lasers femtosecondes de haute puissance ne permettent de mesurer les profils spatial et temporel de l'impulsion que de façon indépendante.L'objectif de cette thèse était de développer des techniques permettant de mesurer les couplages spatio-temporels afin de pouvoir quantifier leur effet et de les corriger dans l'optique d'obtenir l'intensité maximale au foyer. Ainsi, nous avons tout d'abord adapté une technique de caractérisation spatio-temporelle existante à la mesure de lasers TW. Afin d'éviter les contraintes induites au foyer, comme celles liées aux fluctuations de pointé, les mesures ont été réalisées sur le faisceau collimaté. Ajouter une source de référence en parallèle du dispositif initial, nous a aussi permis de prendre en compte les artéfacts de mesure dus aux variations thermiques et mécaniques affectant l'interféromètre. Grâce à cette amélioration, il est possible de reconstruire le profil spatio-temporel complet du faisceau, en particulier son front d'onde.Cependant, les limitations induites par cette technique, nous ont conduit à développer un nouveau dispositif de mesure. Basé sur une corrélation croisée, cette technique consiste à faire interférer le faisceau laser à caractériser avec une partie de ce dernier, suffisamment petite pour ne pas être distordue spatio-temporellement. Nous avons également mis en œuvre une variante de ce dispositif permettant une mesure mono-coup selon une dimension transverse de l'impulsion.A l'aide de ces différentes techniques, nous avons pu caractériser, pour la première fois, plusieurs chaînes lasers TW. Les mesures réalisées ont mis en lumière l'existence de couplages spatio-temporels résiduels conduisant à une baisse significative de l'intensité pic au foyer. Ces résultats montrent qu'il est indispensable de caractériser spatio-temporellement des chaînes lasers femtosecondes de haute puissance dans l'optique d'obtenir l'intensité maximale au foyer. / One of the advantages of high-power femtosecond lasers (TW-PW) is to obtain, at the focus of a focusing optic, very high intensities up to 10^22W.cm^-2 (i.e. an electric field of 2.7 PV.m^-1. Therefore, these lasers chains necessarily deliver beams with large diameter (up to 40 cm) and very short pulses (of the order of tens of femtoseconds). As a consequence, the spatial and temporal properties of the pulse are generally not independent. Such dependence, called spatial-temporal coupling has the effect of increasing the pulse duration and the size of the focal spot, which can lead to a significant reduction of the maximum intensity at the focus. Metrology devices commonly used on these high-power femtosecond lasers allow retriving the spatial and temporal profiles of the pulse only in an independent manner. The aim of this thesis was to develop techniques for measuring spatiotemporal couplings in order to quantify their effect and correct them in order to obtain the maximum intensity at focus. First of all, we adapted an existing technique of spatio-temporal characterization to the measurement of TW lasers. To avoid the issues induced at the focus, such as those related to jittering, measurements were performed on the collimated beam. By adding a reference source to the original device, we managed to take into account the measurement artifacts due to thermal and mechanical variations affecting the interferometer. With this improvement, it was possible to reconstruct the complete spatio-temporal profile of the beam, particularly its wavefront. However, the limitations imposed by this technique led to the development of a new measurement device. Based on a cross-correlation, this technique consists of making the laser beam to interfere with a part of itself, small enough not to be spatiotemporally distorted. We have also implemented a variant of this device for a single-shot measurement along one transverse dimension of the pulse. Using these techniques, we performed the very first characterization of several TW laser chains. The measurements have revealed the existence of residual space-time couplings leading to a significant decrease of the peak intensity at focus. These results show that it is essential to spatio-temporally characterize high power femtosecond laser chains to obtain the maximum intensity at focus.
52

Développement d’un endomicroscope multiphotonique à deux couleurs pour l’imagerie du métabolisme énergétique cellulaire / Label- free in vivo in situ diagnostic imaging by cellular metabolism quantification with a flexible multiphoton endomicroscope

Leclerc, Pierre 28 September 2017 (has links)
La microscopie multiphotonique est une modalité d’imagerie de pointe offrant des opportunités d’avancées remarquables en biologie mais aussi dans le domaine médical. Afin d’en exploiter pleinement le formidable potentiel au cœur même de la pratique clinique, le développement de nombreuses sondes miniaturisées à fibre optique pour l’endomicroscopie multiphotonique (EMMP) a eu lieu depuis de nombreuses années et dans de nombreux laboratoires français et étrangers. Il s’est pour l'instant confronté à des limitations majeures comme l’impossibilité de recueillir les signaux d’auto-fluorescence des tissus qui sont intrinsèquement faibles comme ceux venant des co-enzymes métaboliques NADH et FAD. Cette limitation compromet l'utilité de l’EMMP en la restreignant à une imagerie morphologique requérant un marquage exogène des tissus. Ce manuscrit présente une architecture d’EMMP permettant de dépasser cette limitation, capable de proposer une imagerie fonctionnelle du métabolisme cellulaire en temps réel, in vivo, in situ, sans marquage. Le prototype d’EMMP proposé est une amélioration du précédent, où les Grisms en réflexions sont remplacés par des Grisms en transmission, permettant d’élargir la bande spectrale d’utilisation et la transmission du système. Ce prototype voit aussi l’adjonction d’un second laser excitateur afin d’accéder aux fluorescences du NADH et du FAD. Les résultats démontrent capable que nous sommes à même d’imager les fluorescences cellulaires intrinsèques au travers de 5 mètres de fibre optique avec une résolution subcellulaire. Parmi celles-ci nous sommes capables d’exciter et de collecter spécifiquement les fluorescences du NADH et du FAD. Enfin nous détectons assez de photons pour disposer d‘informations quantitatives et donc de proposer une image du rapport d’oxydo-réduction optique en endomicroscopie. / Nonlinear microscopy is a cutting edge imaging modality leading to remarkable step forward in biology but also in the clinical field. To use it at its full potential and at the very heart of clinical practice, there has been several development of fiber-based micro-endoscope. The application for those probes is now limited by few major restrictions, such as the impossibility to collect auto-fluorescence signal from tissues theses being inherently weak such as the fluorescence from NADH or FAD. This limitation reduces the usefulness of the micro-endoscope effectively restraining it to morphological imaging modality requiring staining of the tissue. Our aim is to go beyond this limitation, showing cellular metabolism monitoring, in real time, without any staining. The experimental setup is an upgrade of our precedent one where the reflection- based Grism stretcher is replace with a new generation transmission-based Grism stretcher. Another Laser was also added in order to tune the first laser at 860nm to allow FAD imaging and the second one to 760nm for NADH. The results prove that we assess and image the level of NADH and FAD at subcellular resolution through a five-meter-long fiber. Thus we demonstrate that we are capable of measuring the optical redox ratio in a micro-endoscopic configuration.

Page generated in 0.0656 seconds