• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 55
  • 3
  • 3
  • 3
  • 3
  • 3
  • 1
  • Tagged with
  • 56
  • 56
  • 34
  • 34
  • 12
  • 12
  • 9
  • 8
  • 8
  • 7
  • 7
  • 7
  • 7
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Ensaio mecânico e validação experimental por análise pelo método dos elementos finitos 3D de imagem óssea obtida por tomografia computadorizada /

Nogueira, Wellington de Lima. January 2018 (has links)
Orientador: Fellippo Ramos Verri / Banca: Aldiéris Alves Pesqueira / Banca: Pedro Yoshito Noritomi / Resumo: O objetivo desse estudo foi comparar os resultados de rigidez do ensaio mecânico de compressão axial com a rigidez da análise por elementos Finitos (FEA), gerar modelos biomecânicos que apresentem com precisão a geometria tridimensional do osso e realizar análise pelo Método dos Elementos Finitos propondo uma metodologia para a simulação computacional mecânica de estruturas ósseas de peças de fêmures e tíbias de coelhos cadáveres. Previamente ao ensaio mecânico de compressão, fez-se uma análise mecânica da estrutura óssea, reconstruindo 20 modelos a partir de tomografia computadorizada utilizando o software de processamento de imagem ScanIP. Em seguida, foi realizada a análise mecânica de rigidez da estrutura óssea simulada pelo método dos elementos finitos 3D no software Ansys. Após construção da malha de elementos finitos, ensaios mecânicos de compressão axial foram realizados nas amostras e seus resultados de rigidez foram então comparados com os resultados de rigidez do modelo biomecânico. Nessa comparação o menor desvio apresentado foi de 0,02% e o maior desvio foi de 8,68%. A diferença entre a média da rigidez extrínseca dos ensaios foi de 1,07%. A média dos resultados para a rigidez intrínseca dos modelos biomecânicos obtidas do pós processamento foi 25258,63 N⁄mm. Concluiu-se que o uso dessa metodologia nos permitiu uma validação experimental do método dos elementos finitos aplicados à biomecânica das amostras testadas. Além disso, foi possível predizer o comportament... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to compare the stiffness results of the axial compression mechanical test with the FEA stiffness, to generate biomechanical models that accurately present the three- dimensional bone geometry and to perform analysis by the Finite Element Method proposing a methodology for the mechanical computational simulation of bony structures using parts of femurs and tibiae from rabbits that were healthy. Prior to mechanical compression testing, it was made a mechanical analysis of the bone structure, rebuilding 20 models from computed tomography using image processing software ScanIP. Then, it was performed mechanical analysis of stiffness of the simulated bone structure by the 3D finite element method in Ansys software. After finite element mesh construction, axial compression tests were performed on the samples and their stiffness results were compared with the stiffness results of the biomechanical model. In this comparison, the lowest deviation was 0,02% and the highest deviation was 8,68%. The difference between the mean extrinsic stiffness of the tests was 1.07%. The average of the results for the intrinsic rigidity of the biomechanical models obtained from the post-processing was 25258,63 N⁄mm. It was concluded that the use of this methodology enabled experimental validation of finite element method applied to biomechanics. Moreover, it was possible to predict the behavior of the bone because the accuracy of the analysis is better the more the biomechani... (Complete abstract click electronic access below) / Mestre
2

Ensaio mecânico e validação experimental por análise pelo método dos elementos finitos 3D de imagem óssea obtida por tomografia computadorizada / Mechanical testing and experimental validation by by the 3D finite element analysis of bone imaging obtained by computed tomography

Nogueira, Wellington de Lima [UNESP] 05 September 2018 (has links)
Submitted by WELLINGTON DE LIMA NOGUEIRA null (wellnogue@gmail.com) on 2018-09-11T13:34:22Z No. of bitstreams: 1 Dissertacao_Wellington.pdf: 1914218 bytes, checksum: 7a8dd3c4b8a4953eeee744de302ddbbe (MD5) / Rejected by Ana Paula Rimoli de Oliveira null (anapaula@foa.unesp.br), reason: Favor incluir ficha catalográfica. on 2018-09-11T14:45:28Z (GMT) / Submitted by WELLINGTON DE LIMA NOGUEIRA null (wellnogue@gmail.com) on 2018-09-11T14:53:48Z No. of bitstreams: 1 Dissertacao_Mestrado.pdf: 1866035 bytes, checksum: 7e039256c516a5a862aad1f7ea929f86 (MD5) / Approved for entry into archive by Ana Paula Rimoli de Oliveira null (anapaula@foa.unesp.br) on 2018-09-11T17:23:14Z (GMT) No. of bitstreams: 1 nogueira_wl_me_araca_int.pdf: 1866035 bytes, checksum: 7e039256c516a5a862aad1f7ea929f86 (MD5) / Made available in DSpace on 2018-09-11T17:23:14Z (GMT). No. of bitstreams: 1 nogueira_wl_me_araca_int.pdf: 1866035 bytes, checksum: 7e039256c516a5a862aad1f7ea929f86 (MD5) Previous issue date: 2018-09-05 / Outra / O objetivo desse estudo foi comparar os resultados de rigidez do ensaio mecânico de compressão axial com a rigidez da análise por elementos Finitos (FEA), gerar modelos biomecânicos que apresentem com precisão a geometria tridimensional do osso e realizar análise pelo Método dos Elementos Finitos propondo uma metodologia para a simulação computacional mecânica de estruturas ósseas de peças de fêmures e tíbias de coelhos cadáveres. Previamente ao ensaio mecânico de compressão, fez-se uma análise mecânica da estrutura óssea, reconstruindo 20 modelos a partir de tomografia computadorizada utilizando o software de processamento de imagem ScanIP. Em seguida, foi realizada a análise mecânica de rigidez da estrutura óssea simulada pelo método dos elementos finitos 3D no software Ansys. Após construção da malha de elementos finitos, ensaios mecânicos de compressão axial foram realizados nas amostras e seus resultados de rigidez foram então comparados com os resultados de rigidez do modelo biomecânico. Nessa comparação o menor desvio apresentado foi de 0,02% e o maior desvio foi de 8,68%. A diferença entre a média da rigidez extrínseca dos ensaios foi de 1,07%. A média dos resultados para a rigidez intrínseca dos modelos biomecânicos obtidas do pós processamento foi 25258,63 N⁄mm. Concluiu-se que o uso dessa metodologia nos permitiu uma validação experimental do método dos elementos finitos aplicados à biomecânica das amostras testadas. Além disso, foi possível predizer o comportamento do osso visto que a precisão da análise é melhor quanto mais o modelo biomecânico se aproxima da estrutura real. / The aim of this study was to compare the stiffness results of the axial compression mechanical test with the FEA stiffness, to generate biomechanical models that accurately present the three- dimensional bone geometry and to perform analysis by the Finite Element Method proposing a methodology for the mechanical computational simulation of bony structures using parts of femurs and tibiae from rabbits that were healthy. Prior to mechanical compression testing, it was made a mechanical analysis of the bone structure, rebuilding 20 models from computed tomography using image processing software ScanIP. Then, it was performed mechanical analysis of stiffness of the simulated bone structure by the 3D finite element method in Ansys software. After finite element mesh construction, axial compression tests were performed on the samples and their stiffness results were compared with the stiffness results of the biomechanical model. In this comparison, the lowest deviation was 0,02% and the highest deviation was 8,68%. The difference between the mean extrinsic stiffness of the tests was 1.07%. The average of the results for the intrinsic rigidity of the biomechanical models obtained from the post-processing was 25258,63 N⁄mm. It was concluded that the use of this methodology enabled experimental validation of finite element method applied to biomechanics. Moreover, it was possible to predict the behavior of the bone because the accuracy of the analysis is better the more the biomechanical model approaches the actual structure.
3

Análise biomecânica do andamento de potros da raça mangalarga marchador aos 30 e 180 dias de idade /

Soares, Carolina de Marchi. January 2017 (has links)
Orientador: Juliana Regina Peiró / Coorientador:Lina Maria Wehrle Gomide / Banca: Katia de Oliveira / Banca: José Correa de Lacerda Neto / Resumo: O método acelerométrico, para a análise biomecânica quando usado a campo tem mostrado vantagens com relação à videogrametria, permitindo obter dados cinemáticos e cinéticos e possuindo um processamento de dados mais rápido. Objetivou-se avaliar o efeito do crescimento sobre as características biomecânicas do passo e da marcha de potros da raça Mangalarga Marchador aos 30 e 180 dias de idade, e estabelecer parâmetros de referência para a raça. Os potros foram equipados com o sistema de análise de andamento Equimetrix® e acompanharam a trajetória da mãe, puxada no cabresto pelo treinador, à marcha e ao passo, com velocidade acompanhada por GPS. As variáveis cinemáticas (comprimento e frequência das passadas, regularidade, simetria e deslocamento dorsoventral do animal) e cinética (propulsão, potências dorsoventral e mediolateral e potência total) foram calculadas e obtidas com o equipamento de análise de andamento Equimetrix®. Durante o passo, as variáveis cinemáticas e cinéticas não apresentaram diferenças entre as duas idades. No andamento marcha, somente as variáveis frequência da passada (p=0,0092), simetria (p=0,0282) e potencia mediolateral (p=<0,0001) demonstraram alterações significativa entre as idades dos potros. Apenas a variável cinética potencia mediolateral (p=<0,0001) diferiu entre as idades. Conclui-se que a maior parte das características biomecânicas (cinemáticas e cinéticas) avaliadas, não se alterou nos potros da raça Mangalarga Marchador, à marcha e ao ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract:The acelerometric method when used to analyze biomechanical parameters in the field has shown advantages in relation to the videogrammetry, enabling to obtain kinematic and kinetic data, and allowing faster gait data processing. The goals of this study was to evaluate the biomechanical characteristics of nine foals, Mangalarga Marchador breed, at 30 and at 180 days of age, to establish parameters for the marcha gait in this breed. Foals were equipped with the gait analysis system Equimetrix®, and were allowed to follow the trajectory of their dams, at speed controlled by GPS. Kinematic (length and frequency of steps, and dorsoventral displacement of the animal) and kinetics (propulsion force) variables were calculated and obtained with the Equimetrix®. This technique is helpful to record the 3D acceleration data (longitudinal, dorsoventral and mediolateral) during the exercise. During step, the kinematic and kinetic characteristics did not change in the foals. During march gait, mean values for step frequency (SF) and symmetry were statistically different between the ages. It was concluded that most of the biomechanical characteristics (kinematic and kinetic) evaluated, did not change in the Mangalarga Marchador foals, gait and step in the first six months of age. To determine if this pattern will be maintained, we suggest continuity of the serial evaluation of gait of these foals until they reach adulthood / Mestre
4

Comportamento de parâmetros metabólicos, biomecânicos e eletromiográficos na caminhada de indivíduos portadores de insuficiência cardíaca e transplantados cardíacos

Bona, Renata Luisa January 2015 (has links)
A insuficiência cardíaca (ICC) altera de forma relevante a caminhada. São encontradas características como, por exemplo, redução da velocidade, fadiga precoce, hiperventilação, e estas limitam a capacidade do indivíduo de manter a caminhada por um longo período, sendo necessárias diversas pausas para o organismo se recuperar. Pacientes que realizaram transplante cardíaco (TC) também apresentam alterações físicas, relacionadas à situação pré-operatória e ao pós-operatório, porém, para esta população, não foram encontrados estudos sobre a mecânica e eletromiografia da caminhada. Objetivo: o objetivo desta pesquisa foi verificar e comparar variáveis metabólias (custo de transporte - C, eficiência ventilatória), biomecânicas (recovery, trabalho mecânico interno - Wint, trabalho mecânico externo - Wext, trabalho mecânico total - Wtot, eficiência mecânica - Eff) e eletromiográficas (custo eletromiográfico - CEMG e coativação no membro inferior) durante a caminhada na esteira rolante, em diferentes velocidades, de pacientes portadores de ICC, pacientes com TC e grupo controle saudável. Métodos: participaram desta pesquisa 12 pacientes portadores de ICC, 12 controles (pareado por sexo e idade) e 5 paciente com TC. Foi realizada análise do consumo de oxigênio, ao mesmo tempo cinemetria 3D (duas câmeras de vídeo) e atividade eletromiográfica (quatorze músculos). Para garantir a simultaneidade dos dados foi utilizada uma unidade de sincronismo. Após definir a velocidade autosselecionada (VAS) foram determinadas mais quatro velocidades de caminhada para o protocolo. Além da autosselecionada foram definidas duas velocidades acima (+40 e +20%) e abaixo (-40 e -20%) desta. Para os dados de C, recovery, Wint, Wext, Wtot, Eff, CEMG e coativação foram utilizadas rotinas desenvolvidas em Matlab®. Resultados: pacientes portadores de ICC e TC apresentam maior C, Wint, Wext e Wtot, CEMG e % coativação no membro inferior, menor recovery e Eff na VAS quando comparados aos controles. A economia e otimização do mecanismo pendular em pacientes portadores de ICC e TC ocorrem em velocidades acima da VAS. Eles não elegem a velocidade ótima como a VAS, como ocorreu no grupo controle. O C e o CEMG apresentam a mesma característica, com maior economia nas velocidades acima da VAS. Além disso, a otimização da mecânica da caminhada, como o observado no recovery, também ocorre acima da VAS. Conclusão: essas novas informações a respeito da caminhada destes grupos sugerem que intervenções durante a reabilitação e treinamento físico tenham como objetivos o aumento da velocidade de caminhada.
5

Estudo do consumo excessivo de aguardente de cana de açúcar na densidade mineral, espessura e resistência às fraturas ósseas em fêmures e tíbias de ratos adultos-jovens /

Silva, Aneliza de Fatima Moraes da. January 2016 (has links)
Orientador: Ana Maria Pires Soubhia / Banca: Wagner Garcez de Mello / Banca: Leonardo Perez Faverani / Resumo: O consumo excessivo de bebidas alcoólicas pode ocasionar problemas econômicos, sociais e psicológicos, além de ser prejudicial a muitos órgãos e tecidos, incluindo o tecido ósseo. O álcool é um fator de desequilíbrio entre a formação e a reabsorção óssea, entre osteoblastos e osteoclastos. Este estudo teve como objetivo analisar os efeitos do consumo excessivo de álcool no tecido ósseo de ratos tratado s com aguardente de cana de açúcar (cachaça), através da análise de fêmures e tíbias de ratos adultos - jovens . 24 ratos foram utilizados ( Rattus norvegicus, albinus, Wistar), divididos em 4 grupos de 6 ani mais, sep arados aleatoriamente, sendo: - Grupo com 90 dias de tratamento, grupo controle (GC90) e grupo experimental (GE90); e g rupo com 105 dias de tratam ento, grupo controle (GC105) e grupo experimental (GE105) . Após tratamento e eutanásia, os fêmures e tíbias foram submetidos as análises radiogr áficas, densitometria óssea e teste biomecânico, respectivamente, avaliados através do Sistema Digital Digora, DEXA (Dual - Energy X - ray Absorptiometry) e Ensaio mecânico. Os dados obtidos foram submeti dos ao test e homocedasticidade com significância de 5% e realizada a nálise de variância - ANOVA - two - way e pós - teste Tukey. Os animais do s grupo s controle s apresentaram maior espessura óssea total e cortical, maior densidade óssea e conteúdo mineral ósseo (p<0,05), assim co mo maior resistência a fraturas comparados com os grupos experimentais. A inda, observou - se que além do padr ão de consumo os efeitos do etilismo sobre o tecido ósseo são influenciados pelo tempo de exposiç ão ao álcool . Conclui - se, assim, qu e o consumo excessivo de aguardente de cana de açúcar além de ocasionar danos ao tecido ósseo, exerce efeito dose dependente nos parâmetros estudados em ratos adultos - jovens. / Abstract: The excessive consumption of alcoholic beverages can cause economic, problems social and psychological, in addition to being harmful to many organs and tissues, including the bone tissue. Alcohol is a factor of an imbalance between the formation and bone resorption, between osteoblasts and osteoclasts. This study aimed to analyze the effects of excessive alcohol consumption in bone tissue of rats treated with Sugarcane brandy (Sugarcane liquor, aqua vitae), through examinations o f femurs and tibias. T wenty - four animals were used (Rattus norvegicus, albinus, Wistar) wer e divided in 4 groups of 6 animals, randomly divided into: - Group with 90 days of treatment, control group (GC90) and experimental group (GE90); and group with 105 days of treatment, control group (GC105) and experimental group (GE105). After treatment and euthanasia, the femurs and tibias radiographic analyzes were submitted, bone densitometry and biomechanical test, respectively, evaluated by Digora Digital System, DEXA (Dual - Energy X - ray Absorptiometry) and mechanical testing. The data were submitted to the homoscedasticity test with 5% significance and performed analysis of variance - ANOVA - two - way and Tukey test . Control group animals showe d highe r total and cortical bone thickness, higher bone density and bone mineral content (p<0,05), as well as greater resistance to fractures comparad to the experimen tal groups. Furthermore, it was observed that in addition to the consumption pattern, the effects of alcohol on bone tissue are influenced by the time of exposure to alcohol. Concluded that the excessive consumption of Sugarcane brandy besides causing damage to the bone tissue exerts dose - dependent effect on the parameters studied in young adult rats. / Mestre
6

Análise biomecânica do andamento de potros da raça mangalarga marchador aos 30 e 180 dias de idade / Biomechanical gait analysis of mangalarga marchador foals at 30 and 180 days of age

Soares, Carolina de Marchi [UNESP] 23 January 2017 (has links)
Submitted by Carolina de Marchi Soares null (carolm.soares@hotmail.com) on 2017-02-06T18:27:27Z No. of bitstreams: 1 DEFINITIVO.pdf: 1413853 bytes, checksum: 378c46ee60d116149679bf305c4e61cb (MD5) / Approved for entry into archive by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br) on 2017-02-08T14:01:31Z (GMT) No. of bitstreams: 1 soares_cm_me_araca.pdf: 1413853 bytes, checksum: 378c46ee60d116149679bf305c4e61cb (MD5) / Made available in DSpace on 2017-02-08T14:01:31Z (GMT). No. of bitstreams: 1 soares_cm_me_araca.pdf: 1413853 bytes, checksum: 378c46ee60d116149679bf305c4e61cb (MD5) Previous issue date: 2017-01-23 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O método acelerométrico, para a análise biomecânica quando usado a campo tem mostrado vantagens com relação à videogrametria, permitindo obter dados cinemáticos e cinéticos e possuindo um processamento de dados mais rápido. Objetivou-se avaliar o efeito do crescimento sobre as características biomecânicas do passo e da marcha de potros da raça Mangalarga Marchador aos 30 e 180 dias de idade, e estabelecer parâmetros de referência para a raça. Os potros foram equipados com o sistema de análise de andamento Equimetrix® e acompanharam a trajetória da mãe, puxada no cabresto pelo treinador, à marcha e ao passo, com velocidade acompanhada por GPS. As variáveis cinemáticas (comprimento e frequência das passadas, regularidade, simetria e deslocamento dorsoventral do animal) e cinética (propulsão, potências dorsoventral e mediolateral e potência total) foram calculadas e obtidas com o equipamento de análise de andamento Equimetrix®. Durante o passo, as variáveis cinemáticas e cinéticas não apresentaram diferenças entre as duas idades. No andamento marcha, somente as variáveis frequência da passada (p=0,0092), simetria (p=0,0282) e potencia mediolateral (p=<0,0001) demonstraram alterações significativa entre as idades dos potros. Apenas a variável cinética potencia mediolateral (p=<0,0001) diferiu entre as idades. Conclui-se que a maior parte das características biomecânicas (cinemáticas e cinéticas) avaliadas, não se alterou nos potros da raça Mangalarga Marchador, à marcha e ao passo, nos primeiros seis meses de idade. Para determinar se este padrão será mantido, sugere-se a continuidade da avaliação seriada da marcha destes potros até atingirem a idade adulta. / The acelerometric method when used to analyze biomechanical parameters in the field has shown advantages in relation to the videogrammetry, enabling to obtain kinematic and kinetic data, and allowing faster gait data processing. The goals of this study was to evaluate the biomechanical characteristics of nine foals, Mangalarga Marchador breed, at 30 and at 180 days of age, to establish parameters for the marcha gait in this breed. Foals were equipped with the gait analysis system Equimetrix®, and were allowed to follow the trajectory of their dams, at speed controlled by GPS. Kinematic (length and frequency of steps, and dorsoventral displacement of the animal) and kinetics (propulsion force) variables were calculated and obtained with the Equimetrix®. This technique is helpful to record the 3D acceleration data (longitudinal, dorsoventral and mediolateral) during the exercise. During step, the kinematic and kinetic characteristics did not change in the foals. During march gait, mean values for step frequency (SF) and symmetry were statistically different between the ages. It was concluded that most of the biomechanical characteristics (kinematic and kinetic) evaluated, did not change in the Mangalarga Marchador foals, gait and step in the first six months of age. To determine if this pattern will be maintained, we suggest continuity of the serial evaluation of gait of these foals until they reach adulthood. / FAPESP: 2014/18323-8
7

Implantes de diâmetros reduzidos instalados em diferentes níveis ósseos influenciam a biomecânica de próteses unitárias na região anterior maxilar ? /

Mestrener, Leandro Rahal. January 2019 (has links)
Orientador: Fellippo Ramos Verri / Resumo: O objetivo deste estudo foi avaliar a distribuição de tensão e deslocamento em implantes de diâmetro reduzido em reabilitações unitárias em região maxilar anterior, variando o posicionamento do implante (ao nível ósseo e 1,5 mm infra-ósseo), através do método de elementos finitos tridimensionais (MEF-3D). Quatro modelos 3D representando uma hemisecção do lado direito da região anterior da maxila foram simulados com a presença de coroa cimentada sobre implante (cone morse) de 10mm de comprimento, variando-se o diâmetro do implante (2,9 mm e 3,5 mm) e a instalação dos implantes no tecido ósseo em rebordo alveolar de 4,5 mm de espessura. O modelo ósseo tridimensional foi construído por recomposição tomográfica com uso dos softwares Invesalius e Rhinoceros 3D. O implante e os componentes foram modelados a partir de modificações do formato original no programa SolidWorks e finalizados no Rhinoceros, bem como o desenho da coroa simulada. A discretização dos modelos foi feita no software ANSYS 19.2, incluindo caracterização dos materiais, contatos, elaboração das malhas, condições de carregamento (178N em direção de 0, 30 e 60 graus em relação ao longo eixo do implante) e de contorno (com restrição em direção x, y, z nas secções laterais dos modelos). Os resultados mostraram comportamento biomecânico similar, com diminuição dos níveis de deslocamento e estresse para implantes de 3,5 mm e implantes infra-ósseos, muito embora os valores obtidos estiveram dentro de valores fisiológicos... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Abstract: The Aim of this study was to evaluate the distribution of stress on implants of narrow diameter, in single unit cemented crowns in the anterior maxillary region, varying the position of the implant (at the bone level and 1.5 mm infra-osseous), through the 3D finite element analysis (3D-FEA). Four 3D models representing a right hemisection of the anterior maxillary region were simulated with the presence of a cemented crown over a 10mm long implant (morse cone), with the implant diameter varying among 2.9 mm and 3.5 mm in an simulated alveolar ridge of 4,5mm thickness. The bone of 3D models was simulated by tomographic recomposition using the software Invesalius and Rhinoceros 3D. The implant and components were modeled from modifications of the original design in the SolidWorks software and modeled in the Rhinoceros, as well as the design of the simulated crown. The discretization of the models was done in the ANSYS 19,2 software, including characterization of materials, contacts, meshes, loading conditions (178N towards 0, 30 and 60 degrees in relation to the implant long axis) and boundary conditions in the x, y, z direction in the lateral sections of the models). The results of dislodgment and von Mises showed similar maps distribution, decreasing dislodgment and stress in implants of 3,5mm diameter and in infra-osseous position, besides these results were inside physiologic values. It was possible to conclude that 2.9mm implants were no more biomechanically favo... (Complete abstract click electronic access below) / Mestre
8

Análise biomecânica de opções protéticas para reabilitação de maxila posterior com próteses implantossuportadas de três elementos. Estudo pelo método dos elementos finitos 3D /

Batista, Victor Eduardo de Souza. January 2018 (has links)
Orientador: Eduardo Piza Pellizzer / Coorientador: Fellippo Ramos Verri / Resumo: Proposição: O propósito do estudo foi estudar o comportamento biomecânico de próteses de três elementos implantossuportadas diante das seguintes variáveis: união (coroas unitárias e esplintadas: em linha reta e em posicionamento tripoidal), comprimento e diâmetro do implante, além da redução do número de implantes (pôntico central), utilizando a metodologia de elementos finitos 3D. Material e Método: Vinte e seis modelos tridimensionais foram simulados com o auxílio dos programas InVesalius, Rhinoceros 4.0 e Solidworks 2016. Cada modelo representou uma seção de osso da região posterior maxilar, na forma de um bloco de osso tipo IV (cortical e esponjoso), com a presença de prótese de três elementos suportada por dois ou três implantes, do tipo hexágono externo, em diferentes situações clínicas, variando os fatores união (coroas unitárias e esplintadas: em linha reta e em posicionamento tripoidal), comprimento, diâmetro e número de implantes. Os desenhos tridimensionais foram exportados ao programa de pré- e pós- processamento FEMAP 11.1.2 para a geração da malha e aplicação de carga de 400N axial e 200N oblíqua (45°). Após a resolução do problema matemático por meio do programa de elementos finitos Nei Nastran 11.1, os resultados foram visualizados através de mapas de Tensão Máxima Principal (MPa) e Microdeformação (µε) para tecido ósseo cortical e mapas de Tensão von Mises (MPa) para parafuso de fixação. Resultados: De um modo geral, modelos com coroas esplintadas associadas ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Objective: The aim of this study was to analyze the biomechanical behavior of three-unit fixed prosthesis varying the union (single crowns and splinted crowns: straight-line and offset implant configurations), length, diameter, and the number of implant (supported by two or three implants) by 3D finite element analysis. Material and Methods: Twenty-six 3-D models were simulated with the software's In Vesalius, Rhinoceros 4.0, SolidWorks 2010 and. Each model represented a posterior maxillary bone section simulating type IV bone (cortical and spongy), with presence of 3-units fixed prosthesis supported by two or three dental implants, external hexagonal connection, in different clinical situations, varying the factors union (single crowns and splinted crowns: straight-line and offset implant configurations), length and diameter. The 3D models were exported to the software FEMAP 11.1.2 for pre- and post- processing and mesh generation besides load definition (400N vertical and 200N oblique,45°). After, the models were solved by NeiNastran 11.1 finite element software and the results were visualized by maximum principal stress (MPa) and microstrain (µε) maps to cortical bone tissue and von Mises stress (MPa) map to fixation screws. Results: Overall, the models with splinted crowns associated with offset implant placement showed the best biomechanical behavior. The reduction in the number of implants generated a biomechanical behavior. The increase of the implant diameter in the m... (Complete abstract click electronic access below) / Doutor
9

Comportamento de parâmetros metabólicos, biomecânicos e eletromiográficos na caminhada de indivíduos portadores de insuficiência cardíaca e transplantados cardíacos

Bona, Renata Luisa January 2015 (has links)
A insuficiência cardíaca (ICC) altera de forma relevante a caminhada. São encontradas características como, por exemplo, redução da velocidade, fadiga precoce, hiperventilação, e estas limitam a capacidade do indivíduo de manter a caminhada por um longo período, sendo necessárias diversas pausas para o organismo se recuperar. Pacientes que realizaram transplante cardíaco (TC) também apresentam alterações físicas, relacionadas à situação pré-operatória e ao pós-operatório, porém, para esta população, não foram encontrados estudos sobre a mecânica e eletromiografia da caminhada. Objetivo: o objetivo desta pesquisa foi verificar e comparar variáveis metabólias (custo de transporte - C, eficiência ventilatória), biomecânicas (recovery, trabalho mecânico interno - Wint, trabalho mecânico externo - Wext, trabalho mecânico total - Wtot, eficiência mecânica - Eff) e eletromiográficas (custo eletromiográfico - CEMG e coativação no membro inferior) durante a caminhada na esteira rolante, em diferentes velocidades, de pacientes portadores de ICC, pacientes com TC e grupo controle saudável. Métodos: participaram desta pesquisa 12 pacientes portadores de ICC, 12 controles (pareado por sexo e idade) e 5 paciente com TC. Foi realizada análise do consumo de oxigênio, ao mesmo tempo cinemetria 3D (duas câmeras de vídeo) e atividade eletromiográfica (quatorze músculos). Para garantir a simultaneidade dos dados foi utilizada uma unidade de sincronismo. Após definir a velocidade autosselecionada (VAS) foram determinadas mais quatro velocidades de caminhada para o protocolo. Além da autosselecionada foram definidas duas velocidades acima (+40 e +20%) e abaixo (-40 e -20%) desta. Para os dados de C, recovery, Wint, Wext, Wtot, Eff, CEMG e coativação foram utilizadas rotinas desenvolvidas em Matlab®. Resultados: pacientes portadores de ICC e TC apresentam maior C, Wint, Wext e Wtot, CEMG e % coativação no membro inferior, menor recovery e Eff na VAS quando comparados aos controles. A economia e otimização do mecanismo pendular em pacientes portadores de ICC e TC ocorrem em velocidades acima da VAS. Eles não elegem a velocidade ótima como a VAS, como ocorreu no grupo controle. O C e o CEMG apresentam a mesma característica, com maior economia nas velocidades acima da VAS. Além disso, a otimização da mecânica da caminhada, como o observado no recovery, também ocorre acima da VAS. Conclusão: essas novas informações a respeito da caminhada destes grupos sugerem que intervenções durante a reabilitação e treinamento físico tenham como objetivos o aumento da velocidade de caminhada.
10

Estudo comparativo das tensões e microdeformações ao redor de pilares protéticos microunit e ucla sob carregamento axial estático

Santis, Leandro Ruivo de [UNESP] 03 December 2015 (has links) (PDF)
Made available in DSpace on 2016-04-01T17:55:16Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-12-03. Added 1 bitstream(s) on 2016-04-01T18:01:17Z : No. of bitstreams: 1 000860699.pdf: 2264641 bytes, checksum: 4f5c8ea2c3254608562a9141ab7a55ca (MD5) / O objetivo deste estudo in vitro foi comparar a microdeformação e a concentração de tensões ao redor de implantes, geradas por cargas axiais estáticas, em pilares protéticos microunit e ucla, por meio da extensometria e fotoelasticidade. Foram confeccionados dois blocos em poliuretano, sendo inseridos três implantes de hexágono externo em cada. Os implantes do primeiro bloco receberam pilares protéticos microunit e, nos implantes do segundo bloco, foram instalados pilares protéticos ucla. As respectivas coifas plásticas foram posicionadas sobre os pilares protéticos microunit. As coifas plásticas microunit e ucla foram adaptadas a uma estrutura em resina padronizada e fundidas em liga Ni-Cr. Os blocos foram duplicados em resina fotoelástica. As supraestruturas metálicas foram parafusadas sobre os respectivos pilares protéticos. Os blocos fotoelásticos foram submetidos a uma carga axial de 7,5 kgf usando um dispositivo de aplicação de carga adaptado em polariscópio. Foram colados quatro extensômetros na superfície superior de cada bloco em poliuretano, tangenciando cada um dos implantes. Foi utilizado um dispositivo de aplicação de cargas com carga axial de 30 kgf sobre os pontos A, B e C, durante 10 segundos. Os dados obtidos foram analisados estatisticamente através do teste RM ANOVA dois fatores e teste post hoc de Sidak (p<0,05). Os pilares protéticos ucla apresentaram menores valores médios de microdeformação (597,8 με), quando comparado aos pilares protéticos microunit (988,3 με). O fator pilar foi estatisticamente significante (p <0,0001), o ponto de aplicação da carga não foi estatisticamente significante (p = 0,9437). Os pilares protéticos ucla mostraram padrões de distribuição de tensão semelhantes aos pilares protéticos microunit. O padrão de distribuição das tensões foi diferente no ponto de aplicação de carga B. Em conclusão, a p presença de pilar prótetico convencional interferiu.... / The aim of this in vitro study was to compare microstrain and stress development around implants during axial loading, varying abutment type and load application point, using strain gauge and photoelastic analysis. Two polyurethane blocks were made, being inserted three external hexagon implants each. Microunit abutments were screwed on the first block and UCLA abutments were screwed on the second block. The respective plastic copings were installed onto the microunit abutments. The plastic copings and UCLA abutments were adapted to a standard resin pattern and cast in Ni-Cr alloy. The blocks were replicated in photoelastic resin. The metallic structures were screwed into the microunit abutments and into the implant plataform, respectively. The photoelastic blocks were submitted to a static vertical 7,5 kgf load using a load application device adapted on polariscope. Four strain gauges were bonded to the surface of each polyurethane block, tangetially to each implant. A static vertical 30 kgf load was applied for 10 seconds, using a load application device on points A, B and C. The data were analyzed by two-way RM ANOVA and Sidak's post hoc test (p< 0.05). Ucla abutments showed lower microstrain mean values (597,8 με) when compared to microunit abutments (988,3 με). The abutment factor was statistically significant (p<0.0001), load application point wasn't statistically significant (p=0,9437). UCLA system showed similar stress distribution patterns to conventional abutments. The pattern of stress distribution was different at point B. In conclusion, the presence of conventional prosthetic pillar interfered in stress distribution and microstrain development

Page generated in 0.0912 seconds