• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 55
  • 3
  • 3
  • 3
  • 3
  • 3
  • 1
  • Tagged with
  • 56
  • 56
  • 34
  • 34
  • 12
  • 12
  • 9
  • 8
  • 8
  • 7
  • 7
  • 7
  • 7
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Comportamento biomecânico de diferentes protocolos cirúrgicos/protéticos para maxila atrófica: análise fotoelástica e extensométrica / Biomechanical behavior of diferente surgical protocols for atrofic maxillas: photoelastic and Strain Gauge analysis

Campaner, Marcio [UNESP] 18 January 2019 (has links)
Submitted by Marcio Campaner (marciocampaner17@gmail.com) on 2019-01-30T01:36:27Z No. of bitstreams: 1 Dissertacao FINAL.pdf: 1090929 bytes, checksum: e09668532be013be367eec9ff777fa8c (MD5) / Approved for entry into archive by Claudio Hideo Matsumoto null (claudio@foa.unesp.br) on 2019-01-30T13:03:21Z (GMT) No. of bitstreams: 1 campaner_m_me_araca_int.pdf: 1059060 bytes, checksum: 600ec274c934bb60162a9d4fc4bbf5be (MD5) / Made available in DSpace on 2019-01-30T13:03:21Z (GMT). No. of bitstreams: 1 campaner_m_me_araca_int.pdf: 1059060 bytes, checksum: 600ec274c934bb60162a9d4fc4bbf5be (MD5) Previous issue date: 2019-01-18 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Os pacientes com maxila atrófica ainda representam um problema complexo para os cirurgiões dentistas, tornando sua reabilitação um grande desafio, devido à baixa quantidade e qualidade óssea, e também de áreas anatômicas a serem preservadas como a fossa nasal e o seio maxilar que pode apresentar-se pneumatizados. O objetivo deste estudo foi avaliar a distribuição de tensões qualitativa e quantitativamente, por meio da análise fotoelástica (AF) e extensométrica (AE), de três diferentes protocolos alternativos ao procedimento de enxertia óssea para a reabilitação implantossuportada de maxila atrófica: implante convencional (S- standard - 3,75x11,5mm) associado a implante curto (C) (5x7mm), implante convencional (S) associado a implante inclinado em 30º e dois implantes convencionais instalados no eixo axial utilizando prótese com extensão em cantilever. A partir de um protótipo da maxila edêntula com atrofia na região posterior, confeccionada por meio de um modelo digital 3D, os corpos de prova foram divididos em 04 grupos de 01 espécime cada para AF e quatro grupos de 05 espécimes para a AE. Foram confeccionados 24 modelos, destes 4 foram de resina fotoelástica (PL-2) e 20 de poliuretano (F160). Foram utilizados implantes do tipo cone morse e confeccionadas próteses fixas implantossuportadas múltiplas (14-16) parafusadas. Os grupos foram divididos de acordo com protocolo de reabilitação proposto em: ISA - dois implantes (S) paralelos ao eixo axial, sendo um instalado na região do primeiro pré-molar (14) e outro na região do primeiro molar (16); ISAICA - dois implantes instalados paralelos ao eixo axial, sendo um implante (S) na região do primeiro pré-molar (14) e um implante curto (C) na região do primeiro molar (16); ISAISI - dois implantes (S), sendo um paralelo ao eixo axial instalado na região do primeiro pré-molar (14) e outro com inclinação distal de 30° na região do primeiro molar (16) e ISAPC - dois implantes (S) paralelos ao eixo axial instalados na região do primeiro pré-molar (14) e segundo pré-molar (15), com o pôntico (16) em cantiliever. Para AF, o conjunto modelo fotoelástico/implante/prótese foi posicionado em um polariscópio circular associado a uma máquina de ensaio universal (EMIC), sendo aplicada força axial de 100N. As tensões geradas foram registradas fotograficamente e analisadas qualitativamente. Para AE, 6 extensômetros foram posicionados ao redor dos dois implantes de cada grupo. Os sinais elétricos foram captados por um aparelho de aquisição de dados (ASD2002). Os dados quantitativos foram submetidos a ANOVA e ao teste Tukey (P<0.005). Pela AF, os protocolos de tratamento ISAICA e ISAPC apresentaram maior número de franjas de alta tensão em comparação os protocolos ISAISI e ISA. Pela AE, os protocolos ISAICA e ISAPC apresentaram maiores valores de tensão (microstrain), sendo diferentes do grupo controle ISA (P<.005). Já o protocolo ISAICA não apresentou diferença do grupo controle. Conclui-se que o protocolo de reabilitação de maxila atrófica com associação de implante axial e implante com inclinação distal de 30° apresentou o melhor comportamento biomecânico, sendo considerado a melhor alternativa ao procedimento de enxertia óssea para a reabilitação implantossuportada de maxila atrófica. / Patients with atrophic maxillary still represent a challenge to rehabilitate for dentists in general due to limitations on bone quantity and quality and the anatomical setting of the sites to be preserved, such as nasal cavity and maxillary sinus, that could be pneumatized. The aim of this study was to assess qualitative and quantitative the stress distribution, through photoelastic analysis (PA) and strain gauge (SG), of three alternative techniques to bone augmentation procedures for implant placement: standard implant (S- standard - 3,75x11,5mm) associated to short implant (C) (5x7mm), standard implant (S) associated to 30 º tilted implant, two conventional implants placed in the long axis and a cantilever prosthesis. A maxillary prototype model, with posterior atrophic region, was manufactured from a digital 3D model and divided into four groups with 01 specimen for the PA and 05 specimen for the SG. A total of 24 models were manufactured, 4 from photoelastic resin (PL-2) and 20 from polyurethane (F160). Morse taper implants were used and multiple screwed implant supported prostheses were manufactured (14-16). The groups were divided according to the rehabilitation protocol: ISA – two parallel implants in the long axis (S), one in the pre-molar region (14) and in the molar region (16); ISAICA – two parallel implants in the long axis, one standard (S) in the pre-molar region (14) and one short (C) in the molar region (16); ISAISI – two standard implants, one parallel to the long axis (14) and one tilted at 30˚ (16) and ISAPC – two parallel implants in the long axis, in the first (14) and second (15) pre molar region, with a cantilever prostheses (16). For the PA, the assemble photoelastic model/implants/prostheses was positioned in a circular polariscope associated to a universal test machine (EMIC), and an axial load of 100N applied. The tension generated were photographed and analyzed qualitatively. For the SGA, 6 extensometers were attached around two implants of each group. The electoral signals were captured with a data acquisition machine (ASD2001). The data were submitted to ANOVA and Tukey test (P <0.005). By AF, the ISAICA and ISAPC treatment protocols presented higher number of high-voltage fringes compared to the ISAISI and ISA protocols. By the AE, the ISAICA and ISAPC protocols presented higher values of tension (microstrain), being different from the ISA control group (P <.005). The ISAICA protocol did not present any difference in the control group. It was concluded that the protocol of atrophic maxilla rehabilitation with an association of axial implant and implant with distal inclination of 30 ° presented the best biomechanical behavior, being considered the best alternative to the bone grafting procedure for the implant-supported rehabilitation of atrophic maxilla.
22

Comportamento mecânico e características de desgaste de diferentes sistemas de encaixe utilizados em sobredentaduras mandibulares / Mechanical behavior and wear characteristics of different attachment systems used in mandibular overdentures

Marin, Danny Omar Mendoza [UNESP] 06 February 2017 (has links)
Submitted by DANNY OMAR MENDOZA MARIN (danimar_me@hotmail.com) on 2017-02-22T21:45:34Z No. of bitstreams: 1 Tese Final Danny Corrigida Biblioteca final.pdf: 2728503 bytes, checksum: e912b70bf63a5f549b90be2b63fe717e (MD5) / Approved for entry into archive by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br) on 2017-02-24T18:26:59Z (GMT) No. of bitstreams: 1 marin_dom_dr_arafo.pdf: 2728503 bytes, checksum: e912b70bf63a5f549b90be2b63fe717e (MD5) / Made available in DSpace on 2017-02-24T18:26:59Z (GMT). No. of bitstreams: 1 marin_dom_dr_arafo.pdf: 2728503 bytes, checksum: e912b70bf63a5f549b90be2b63fe717e (MD5) Previous issue date: 2017-02-06 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Uma ampla variedade de sistemas de encaixe para sobredentaduras retidas por implantes estão atualmente disponíveis no mercado. Estudos para avaliar o comportamento mecânico desses sistemas de encaixe tornam-se ainda necessários para uma maior compreensão das suas propriedades biomecânicas quando da sua indicação e seleção durante a confecção de sobredentaduras mandibulares. Objetivos: Avaliar a força de retenção inicial, resistência à fadiga, característica de desgaste e a influência da distância entre os implantes (16 mm, 22 mm e 29 mm) de diferentes sistemas de encaixe (O´ring, Bola Mini, Equator) utilizados em sobredentaduras mandibulares retidas por dois implantes. Metodologia: 90 corpos de prova foram confeccionados, os quais foram divididos em 09 grupos experimentais (n=10) de acordo com as distâncias estabelecidas e o sistema de encaixe. Os corpos de prova foram submetidos ao teste de fadiga mecânica utilizando a máquina de ensaios MTS 810 - Material Test System, durante 5500 ciclos de inserção/remoção (f = o,8 Hz), imersas em saliva artificial. Valores de retenção foram obtidos durante 4 períodos (0, 1500, 3000, 5500 ciclos) utilizando uma célula de carga de 1 kN e velocidade constante de 1mm/min. Um espécime de cada sistema de encaixe, utilizando a distância entre os implantes de 22 mm, foi selecionado de maneira aleatória e analisado por meio de um microscópio eletrônico de varredura para avaliação qualitativa da superfície. O teste de ANOVA dois e três fatores e o teste de comparações múltiplas de Bonferroni foram utilizados para análise estatística (α=0.05). Resultados. Para a distância de 22 mm, o sistema O´ring permaneceu estável durante todos os períodos testados e apresentou os menores valores de retenção que os sistemas Bola Mini e Equator (p<. 0,05). O sistema Bola Mini apresentou um aumento significativo na força de retenção após o teste de fadiga (0 ciclos=21.04±3.29; 5500 ciclos=24.01±3.30). Entretanto, o sistema Equator apresentou uma diminuição significativa na força de retenção após cada período testado (p< 0,05), mas os valores de retenção foram maiores que os outros sistemas (p< 0,05). A distância entre os implantes influenciou significativamente (p< 0,05) em um aumento na força de retenção dependendo do tipo de sistema de encaixe (Bola Mini e Equator) quando os implantes foram posicionados a uma distância de 29 mm. Conclusões: O tipo de sistema de encaixe e a distância entre os implantes influência na força de retenção. O sistema Equator apresentou os maiores valores de retenção para todas as distâncias durante todos os períodos de avaliação seguido pelo sistema Bola Mini e O´ring. Os anéis de retenção dos sistemas Bola Mini e Equator apresentaram deformação e desgaste nas suas superfícies sem fratura do anel de poliamida.
23

Exercício resistido no tratamento e prevenção de osteopenia de ratos machos jovens /

Souza, Bruno Saturnino de. January 2015 (has links)
Resumo:A estrutura óssea do ser humano bem como o processo de consolidação óssea são alvos de estudos constantes em todo o mundo. Fraturas e lesões são consequências da fragilidade óssea, normalmente causadas pela osteoporose, um grave problema de saúde pública. Estudos mostram que essa fragilidade pode ser atenuada pela atividade física regular e treinamento de força. O objetivo dessa pesquisa foi avaliar a eficácia do exercício físico resistido frente a osteopenia induzida em ratos que permaneceram com ausência de carga em seus membros pélvicos. O modelo foi o de suspensão da cauda em ratos. Estes foram distribuídos em quatro grupos: C, controle, com período experimental em gaiola; S, suspenso por 21 dias e colocados em solo por mais 21 dias; E, submetido a exercício em escada durante 21 dias e, depois, mantido em solo por mais 21 dias e SE, suspenso por 21 dias e depois submetido a exercício em escada durante 21 dias. Foram realizadas análise de densitometria óssea e ensaio mecânico na tíbia dos animais para avaliar a qualidade do tecido ósseo após o período experimental. Pelos resultados, foi possível observar que o exercício físico com carga e intensidade adequada resulta em aumento da rigidez, força máxima, densidade mineral óssea e conteúdo mineral ósseo caracterizando uma recuperação da qualidade do osso proporcionada pelo exercício físico. Desta forma, conclui-se que o exercício físico com carga resistida e intensidade adequada resulta em remodelação óssea positiva frente a suspenção pela cauda, que por sua vez induz a fragilidade óssea semelhante a osteopenia, sendo eficaz no tratamento e prevenção dessa enfermidade / Abstract:The bone structure of the human being and the bone healing process are constant targets of studies worldwide. Fractures and injuries are consequences of bone frailty, usually caused by osteoporosis, a serious public health problem. Studies have shown that regular physical activity and strength training can mitigate this weakness. The purpose of this study was to evaluate the effectiveness of the resistance exercise against osteopenia induced in rats that remained with no load on their hind limbs. The suspension model used was the rat's tail model suspension. These rats were divided into four groups: C, control, with trial cage; S, suspended for 21 days and placed in soil for 21 days; E subjected to exercise ladder for 21 days and then kept in the soil for 21 days, and SE suspended for 21 days and then subjected to exercise ladder for 21 days. Bone densitometry analysis and mechanical testing in the tibia of the animals were realized to verify the quality of bone tissue after the trial period. It was possible to observe in the results that the exercise load and proper intensity results in increased rigidity, maximum strength, bone mineral density and bone mineral content featuring a recovery of bone quality provided by exercise. In this way, it was concluded that physical exercise with appropriate intensity and repeated load results in a positive bone remodeling before the suspension by the tail, which in turn induces a similar bone fragility osteoporosis, being effective in the treatment and prevention of this disease / Orientador:Mario Jefferson Quirino Louzada / Banca:Gilberto Aparecido Claclete / Banca:Luiz Eduardo Correa Fonseca / Mestre
24

A Aprendizagem Significativa da Biomecânica e da Análise Qualitativa do Movimento por professores de Educação Física

Belmont, Rachel Saraiva January 2015 (has links)
Made available in DSpace on 2016-03-15T14:22:48Z (GMT). No. of bitstreams: 2 rachel_belmont_ioc_dout_2015.pdf: 8067205 bytes, checksum: 8d1705366da9679ab366ca49d1086cc6 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2016-01-13 / A Biomecânica é uma disciplina de natureza interdisciplinar, comumente percebida como de difícil compreensão pelos estudantes e parece ser pouco utilizada por professores de Educação Física. Assumindo este conhecimento como essencial para a prática deste profissional, o presente estudo, de abordagem qualitativa e do tipo pesquisa intervenção, foi subsidiado principalmente pela Teoria da Aprendizagem Significativa e teve como objetivo compreender o processo de aprendizagem significativa dos conceitos centrais da Biomecânica por professores de Educação Física que atuam na Educação Básica. Para isso, foram oferecidos dois cursos de extensão na Fundação Oswaldo Cruz, Rio de Janeiro. O primeiro foi oferecido com frequência semanal e o segundo, no formato concentrado de uma semana. As intervenções foram planejadas, desenvolvidas e avaliadas à luz do referencial teórico assumido. Os registros foram variados e obtidos por meio das fichas de inscrição, notas de campo, testes, atividades escritas, gravações em áudio das entrevistas, das aulas e dos trabalhos em grupo desenvolvidos pelos alunos. Além destes, foi solicitado aos alunos que respondessem um questionário on-line enviado quatro meses após o término de cada curso. O conjunto dos dados produzidos, a partir dos registros obtidos, compôs a descrição interpretativa do processo de ensino e a avaliação da aprendizagem dos alunos. Os dados foram categorizados por meio da Análise de Conteúdo, conforme a natureza dos mesmos Os resultados sugerem que embora o conhecimento dos alunos, de ambos os cursos, tenha evoluído, seria necessário mais tempo em contato com o conteúdo para que fossem estabelecidas relações conceituais que os permitissem interpretar os fenômenos trabalhados com mais propriedade. Conhecimentos prévios ausentes, alternativos ou errôneos, memória afetiva negativa relacionada à Física e/ ou à Biomecânica desenvolvida ao longo da formação dos alunos, podem ter dificultado a captação de significados e a posterior aprendizagem significativa das ideias discutidas. O modelo de Análise Qualitativa do Movimento utilizado, embora correspondesse a parte do conteúdo dos cursos, se mostrou como boa estratégia para o ensino da Biomecânica qualitativa e como instrumento de avaliação dos professores. Os cursos atenderam os objetivos pois favoreceram as negociações de significados dos conceitos entre os estudantes e destes com a professora, oferecerem situações diversas nas quais os alunos pensaram os mesmos conceitos em diferentes contextos, além de promoverem a sensibilização dos participantes para a importância da Biomecânica no ensino da Educação Física escolar e para a formação permanente. Este estudo contribuiu para o aumento do conhecimento sobre o processo de ensino e de aprendizagem da Biomecânica, assim como sobre a formação do profissional de Educação Física e a prática de ensino e investigação fundamentada na Teoria da Aprendizagem Significativa / Biomechanics is a discipline characterized by its interdisciplinary nature and students perception of it’s difficulty. It is well known that Physical Education profession a ls also have difficulties applying biomechanical concepts in their daily teaching practice . As biomechanical knowledge is essential to the teaching of motor skills, the aim of this qualittative study was understad the biomechanical meaning f ull earning process of Physical Education teachers who work a t p re-college education. The records were obt a ined from registration forms, researcher’ s field notes, tests , written activities, audio recordings of interviews of classes, and group works developed by theteac her s. In addition, teachers were a sked to answer an online questionnaires entafterthe end ofeach course . The data we’re categorized according to the nature of the records using content analysis to document the teacher’s learning process. Our findings suggest that although teacher’s knowledge of biomechanical concepts improved after both courses, more tim e would be necessary to establish the conceptual relationships that would allow them to apply the s elected biomechanical phenomena with assurance. Many fac tors could have contributed to hinder meaning full earning concepts such as missing or erroneous prior knowledge and negative affective memory related to Physics and/or Biomechanics developed during the teachers’ previous education. The choice for qualitative analysis of movement appeared to be a good strategy for teaching qualitative biomechanical concepts and evaluating teachers’ application of that knowledge. The two courses seemed to have achieved its go a ls because they triggered and stimulated concept meanings negotiations among students and between them and the professor, and also offered a variety of situations in which the teachers applied the same concepts in different contexts. In addition, the co urses raised teacher’ s awareness of the import ance of Biomechanic s in Physical Education teaching and continuing education. This study contributed to knowledge about the processes of teaching and learning Biomechanics in continuing education, as well as the professional tra ining of Physical Education professionals according to the Meaningfull Learning Theory
25

Exercício resistido no tratamento e prevenção de osteopenia de ratos machos jovens / Resistance exercise in treatment and prevention of osteopenia in young male rats

Souza, Bruno Saturnino de [UNESP] 18 December 2015 (has links)
Submitted by BRUNO SATURNINO DE SOUZA null (br_saturnino@hotmail.com) on 2016-01-14T11:38:22Z No. of bitstreams: 1 Dissertação - Bruno Saturnino de Souza.pdf: 1024042 bytes, checksum: ec97801fa7722510ebbe5e6c15c6ab16 (MD5) / Approved for entry into archive by Ana Paula Grisoto (grisotoana@reitoria.unesp.br) on 2016-01-15T11:23:15Z (GMT) No. of bitstreams: 1 souza_bs_me_araca_int.pdf: 1024042 bytes, checksum: ec97801fa7722510ebbe5e6c15c6ab16 (MD5) / Made available in DSpace on 2016-01-15T11:23:15Z (GMT). No. of bitstreams: 1 souza_bs_me_araca_int.pdf: 1024042 bytes, checksum: ec97801fa7722510ebbe5e6c15c6ab16 (MD5) Previous issue date: 2015-12-18 / Não recebi financiamento / A estrutura óssea do ser humano bem como o processo de consolidação óssea são alvos de estudos constantes em todo o mundo. Fraturas e lesões são consequências da fragilidade óssea, normalmente causadas pela osteoporose, um grave problema de saúde pública. Estudos mostram que essa fragilidade pode ser atenuada pela atividade física regular e treinamento de força. O objetivo dessa pesquisa foi avaliar a eficácia do exercício físico resistido frente a osteopenia induzida em ratos que permaneceram com ausência de carga em seus membros pélvicos. O modelo foi o de suspensão da cauda em ratos. Estes foram distribuídos em quatro grupos: C, controle, com período experimental em gaiola; S, suspenso por 21 dias e colocados em solo por mais 21 dias; E, submetido a exercício em escada durante 21 dias e, depois, mantido em solo por mais 21 dias e SE, suspenso por 21 dias e depois submetido a exercício em escada durante 21 dias. Foram realizadas análise de densitometria óssea e ensaio mecânico na tíbia dos animais para avaliar a qualidade do tecido ósseo após o período experimental. Pelos resultados, foi possível observar que o exercício físico com carga e intensidade adequada resulta em aumento da rigidez, força máxima, densidade mineral óssea e conteúdo mineral ósseo caracterizando uma recuperação da qualidade do osso proporcionada pelo exercício físico. Desta forma, conclui-se que o exercício físico com carga resistida e intensidade adequada resulta em remodelação óssea positiva frente a suspenção pela cauda, que por sua vez induz a fragilidade óssea semelhante a osteopenia, sendo eficaz no tratamento e prevenção dessa enfermidade. / The bone structure of the human being and the bone healing process are constant targets of studies worldwide. Fractures and injuries are consequences of bone frailty, usually caused by osteoporosis, a serious public health problem. Studies have shown that regular physical activity and strength training can mitigate this weakness. The purpose of this study was to evaluate the effectiveness of the resistance exercise against osteopenia induced in rats that remained with no load on their hind limbs. The suspension model used was the rat’s tail model suspension. These rats were divided into four groups: C, control, with trial cage; S, suspended for 21 days and placed in soil for 21 days; E subjected to exercise ladder for 21 days and then kept in the soil for 21 days, and SE suspended for 21 days and then subjected to exercise ladder for 21 days. Bone densitometry analysis and mechanical testing in the tibia of the animals were realized to verify the quality of bone tissue after the trial period. It was possible to observe in the results that the exercise load and proper intensity results in increased rigidity, maximum strength, bone mineral density and bone mineral content featuring a recovery of bone quality provided by exercise. In this way, it was concluded that physical exercise with appropriate intensity and repeated load results in a positive bone remodeling before the suspension by the tail, which in turn induces a similar bone fragility osteoporosis, being effective in the treatment and prevention of this disease.
26

Comportamento mecânico e características de desgaste de diferentes sistemas de encaixe utilizados em sobredentaduras mandibulares /

Mendoza Marin, Danny Omar. January 2017 (has links)
Orientador: Marco Antonio [UNESP] Compagnoni / Resumo: Uma ampla variedade de sistemas de encaixe para sobredentaduras retidas por implantes estão atualmente disponíveis no mercado. Estudos para avaliar o comportamento mecânico desses sistemas de encaixe tornam-se ainda necessários para uma maior compreensão das suas propriedades biomecânicas quando da sua indicação e seleção durante a confecção de sobredentaduras mandibulares. Objetivos: Avaliar a força de retenção inicial, resistência à fadiga, característica de desgaste e a influência da distância entre os implantes (16 mm, 22 mm e 29 mm) de diferentes sistemas de encaixe (O'ring, Bola Mini, Equator) utilizados em sobredentaduras mandibulares retidas por dois implantes. Metodologia: 90 corpos de prova foram confeccionados, os quais foram divididos em 09 grupos experimentais (n=10) de acordo com as distâncias estabelecidas e o sistema de encaixe. Os corpos de prova foram submetidos ao teste de fadiga mecânica utilizando a máquina de ensaios MTS 810 - Material Test System, durante 5500 ciclos de inserção/remoção (f = o,8 Hz), imersas em saliva artificial. Valores de retenção foram obtidos durante 4 períodos (0, 1500, 3000, 5500 ciclos) utilizando uma célula de carga de 1 kN e velocidade constante de 1mm/min. Um espécime de cada sistema de encaixe, utilizando a distância entre os implantes de 22 mm, foi selecionado de maneira aleatória e analisado por meio de um microscópio eletrônico de varredura para avaliação qualitativa da superfície. O teste de ANOVA dois e três fatores e o ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract:Several attachment systems for mandibular overdentures retained by implants are currently available in the market. Studies to evaluate the mechanical behavior become necessary for a better understanding of the mechanical properties of these components, helping the surgeon dentist in the correct selection during the fabrication of mandibular overdentures. Objectives: To evaluate the initial retention force, fatigue strength, wear characteristic and the influence of the distance between the implants (16 mm, 22 mm and 29 mm) of different attachment systems (O'ring, Mini Ball, Equator) used in mandibular overdentures retained by two implants. Methodology: 90 specimens were fabricated and divided into 9 groups (n = 10) according to the established distances and the attachment system. A mechanical fatigue test was applied to the specimens using a universal testing machine MTS 810 - Material Test System performing 5500 insertion/removal cycles (f=0.8 Hz), immersed in artificial saliva. Retention force values were obtained before and after 1500, 3000, and 5500 cycles using a speed of 1 mm/min and a load cell of 1 kN. One specimen from each group, using the distance between the implants of 22 mm, was randomly selected and analyzed by scanning electron microscopy for qualitative evaluation of surface. Twoway and Three-way repeated measures ANOVA and the Bonferroni post hoc test were used for statistical analyses (α=0.05). Results: For the distance of 22 mm, the O'ring system remained stable during all the periods tested and had the lowest retention values than Mini Ball and Equator systems (p<0.05). The Mini Ball system showed a significant increase in the retention force after the fatigue test (0 cycles = 21.04 ± 3.29; 5500 cycles = 24.01 ± 3.30). However, the Equator system showed a significant decrease in the retention...(Complete abstract electronic access below) / Doutor
27

Avaliação da precisão e distribuição de tensões em próteses fixas sobre implantes de hexágono externo obtidas por diferentes sistemas CAD-CAM /

Mello, Caroline Cantieri de. January 2017 (has links)
Orientador: Eduardo Piza Pellizzer / Banca: Fellippo Ramos Verri / Banca: José Vitor Quinelli Mazaro / Banca: Ricardo Alexandre Zavanelli / Banca: Joel Ferreira Santiago Junior / Resumo: Os sistemas CAD-CAM tem sido responsáveis por automatizar a produção odontológica, otimizando o tempo e tornando este processo cada vez mais viável. Objetivo: O objetivo deste trabalho foi mensurar as desadaptações marginais vertical (DMV) e horizontal positiva (DMHP) e negativa (DMHN) de PPF de zircônia confeccionadas por diferentes sistemas CAD-CAM e por um método convencional, e analisar pelo MEF-3D (método dos elementos finitos tridimensionais) a influência das desadaptações no comportamento biomecânico das estruturas protéticas. Além disso, confeccionar uma revisão sistemática e meta-análise comparando os estudos da literatura que tenham avaliado a desadaptação marginal de próteses e componentes protéticos implantossuportados confeccionados pelos sistemas CAD-CAM e pelo método convencional da fundição por cera perdida. Materiais e Métodos: Quarenta infraestruturas (n=10) foram confeccionadas (G1: Cerec Bluecam, G2: iTero, G3: 3Series, G4: Ni-Cr), e randomizadas para mensuração das desadaptações. Os resultados encontrados foram submetidos à análise de variância (ANOVA), com nível de significância à 5%. Os valores médios de DMV de cada grupo foram utilizados para a confecção de 6 modelos pelo MEF-3D, submetidos à aplicação de forças axiais e oblíquas. Os resultados foram visualizados através de mapas de tensão Von Mises. A revisão sistemática foi desenvolvida de acordo com o PRISMA e registrada na plataforma PROSPERO (CRD42017055685). Resultados: Os resultados ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: CAD - CAM systems in dentistry automate production, thus optimizing time and making the process even more convenient. Purpose : The aim of this study was to measure vertical (VMD) and positive (PHMD) and negative horizontal ( N HMD) marginal discrepancy of FPD frameworks made by different CAD - CAM systems (zirconia Y - TZP) and conventional method (cast), and to analyze by FEA - 3D the biomechanical performance of implant - prosthesis misfit. In addition, to do a systematic review and m eta - analysis comparing studies in the literature that have evaluated the marginal misfit of prostheses and implant - supported prosthetic components made by the CAD - CAM systems and the conventional method of lost - wax casting. Material and Methods: Forty fram eworks (n=10) were fabricated (G1: Cerec Bluecam, G2: iTero, G3: 3Series, G4: Ni - Cr ) and were randomized, to measure the misfits. The results were submitted to analysis of variance (ANOVA), with significance level at 5%. The average values of DMV of each g roup were used to make six models using FEA - 3D, applying axial and oblique loads. The results were analyzed using maps of Von Mises stresses, for each model. The systematic review was developed according to PRISMA statement and was register in the PROSPERO (International prospective register of systematic reviews) ( CRD42017055685). Results: The results of chapter 1 were: the conventional method showing the lowest values of vertical misfit compared to CAD - CAM systems (p<0.05). The CAD - CAM systems showing low est values of PHMD (p=0.014) and the conventional method did not present values of NHMD. In the biomechanical analysis, the oblique loading concentrated a greater amount of stresse s than the axial loading, in all situations evaluated. The fit models presen ted the most favorable biomechanical performance compared...(Complete abstract electronic access below) / Doutor
28

Análise tridimensional da barra palatina e arco contínuo de NiTi para correção da giro-versão e expansão de molares /

Ledra, Ingrid Müller. January 2018 (has links)
Orientador: Luiz Gonzaga [Unesp] Gandini Júnior / Resumo: Objetivo: Quantificar, in vitro e tridimensionalmente, o sistema de força gerado durante o uso da barra palatina de beta-titânio 0,032' x 0,032' (BP) e arco continuo (AC) níquel titânio 0,016' (NiTi) para giro-versão e expansão do primeiro molar superior. Materiais e Métodos: Duas pesquisas científicas foram realizadas e redigidas em dois artigos científicos para avaliar os objetivos apresentados. Resultados: A BP quando utilizada para correção da giro-versão do primeiro molar produziu força vestíbulo palatina, mésio-distal e momento no centro de resistência (Net Mz) maiores que o AC. Nos segundos molares não foram encontradas diferenças em relação a força mésio-distal e momento, mas o AC apresentou força vestíbulo palatal (0,04N). Para expansão do primeiro molar superior as forças mésio distais foram aproximadas para as duas mecânicas a força mésio-distal foi maior na BP (-0,60N) quando comparada ao AC (-0,08N) já o momento foi calculado pelo centro de resistência onde Net Mz da BP teve resultados maiores que o AC. No segundo molar não existiram forças significantes com a mecânica de BP enquanto no AC observou-se forças colaterais de distalização e lingualização além de um Net Mz bastante baixo. Conclusão: Para giro-versão do primeiro molar superior a BP gera forças e momentos de maior magnitude que o AC. No entanto, no segundo molar, forças vestíbulo palatais são maiores no AC. Na mecânica de expansão no primeiro molar as forças transversais são parecidas nas duas mecâni... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Objective: To quantify, in vitro and three-dimensional, the force system generated by a palatine bar (PB) beta-titanium 0.032 "x 0.032" and continuous arch (CA) NiTi 0.016 to derotation and expansion of the maxillary first molar. Methods and Materials: Two research were written in two scientific articles to evaluate the objectives. Results: The PB when used to derotation the molar produced vestibular palatine, mesio-distal force and moment in the center of resistance (Net Mz) greater than the CA. In second molars were not found moment, just vestibular palatine force (0.04N). For the molar expansion mesio-distal force was higher in PB (-0.60N) than in CA (-0.08N) and the momentum was calculated by the center of molar resistance. Net Mz of PB had higher results than CA. In the second molar there were no significant forces with PB mechanics while in CA we observed forces of distalization and lingualization besides a low Net Mz. Conclusion: For the first molar derotation PB generates forces and moments of greater magnitude than the CA. However, in the second molar, palatal vestibular forces are higher in CA. In the expansion mechanics in the first molar, the transverse forces are similar in two mechanicals and there is a greater unwanted moment of rotation in the PB than in CA. While in the second molar side effects are only felt in the mechanics of CA. / Mestre
29

Análise cinemática do tronco, quadril e joelho durante a realização de diferentes tarefas funcionais para avaliação do valgo dinâmico / Kinematic analysis of the trunk, hip and knee during the execution of different tasks to evaluate the functional dynamic valgus

Ana Cristina Corrêa Cervi 24 January 2017 (has links)
Um dos fatores que podem contribuir para as lesões na articulação do joelho é a incapacidade do indivíduo em manter durante atividades funcionais, um bom alinhamento entre os segmentos corporais tais como tronco, quadril e joelho. Na maioria das vezes o aumento do valgo dinâmico de joelho é apontado como um fator etiológico de lesões nessa articulação e sua identificação precoceé importante, bem como de outros fatores biomecânicos. Os testes funcionais para avaliação do valgo são importantes ferramentas para analisar o alinhamento dinâmico entre os segmentos corporais, porém ainda não há na literatura subsídios cinesiológicos que comparem a amplitude articular do joelho, quadril e tronco nas principais tarefas funcionais e utilizadas na prática clínica. Da mesma forma, a relação da cinemática desses segmentos com o torque dos músculos estabilizadores do quadril e joelho ainda é controverso. Objetivos: Comparar os valores angulares dados pela cinemática de tronco, quadril e joelho em cinco diferentes tarefas funcionais utilizadas para avaliação do valgo dinâmicoe correlacionar com o pico de torque de joelho e quadril. Materiais e Métodos: 30 voluntários saudáveis sem historia de dor ou disfunção em membros inferiores, de ambos os sexos (15 homens e 15 mulheres) com idade de 18 a 35 anos realizaram os testes de força muscular isométrica para todos os grupos musculares de joelho e quadril utilizando o Dinamômetro isocinéticoBiodex®. Entre 3 a 7 dias após o teste de força muscular foi realizada a análise cinemática de tronco, quadril e joelho utilizando o Sistema VICON (Centennial, CO, EUA) durante a realização de cinco diferentes tarefas funcionais para avaliação do valgo dinâmico de joelho, sendo elas: descida de degrau, singlelegstepdown, agachamento unipodal, aterrissagem unipodal, drop vertical jump. Resultados: A tarefa dedrop vertical jump apresentou os maiores valores de pico de valgo(média: 20,1º p<=0,04), rotação interna de joelho(média: 9,7º p<=0,003), flexão de quadril(média: 38,8º p<=0,001) e menores valores de rotação de tronco (média: 0,07º p<=0,009). A tarefa de single legstepdown apresentou maiores valores de flexão de tronco (média: 10,2º p<=0,002) em relação às outras tarefas funcionais. Foi observada uma correlação negativa e fraca do pico de torque de rotadores externos de quadril e inclinação ipsilateral de tronco(R= - 0,36; p=0,049) na tarefa de descida de degrau. Não houve evidências de correlação entre o pico de torque de abdutores, adutores, rotadores internos,rotadores externos, flexores, extensores de quadril e flexores e extensores de joelho com a cinemática de joelho, quadril e tronco nas tarefas funcionais de agachamento unipodal, aterrissagem unipodal, drop vertical jump e singlelegstepdown. Conclusão:A compreensão das variáveis cinesiológicas de joelho, quadril e troncoé fundamental para direcionar o clínico na escolha do teste funcional para avaliação do valgo dinâmico.Todas as tarefas analisadas são efetivas para avaliar o valgo dinâmico, porém adrop vertical jumpparece demandar mais estratégias de joelho e quadril, e a tarefasingle legstepdown apresentou maiores alterações cinesiológicasde tronco. Além disso, o pico de torque de quadril e joelho não exerceu influência no desempenho dos testes em indivíduos saudáveis / One of the factors that can contribute to injuries in the knee joint is the individual\'s inability to maintain an alignment between the body segments such as trunk, hip and knee during functional activities. Most of the time the dynamic knee valgus has been suggested as an etiologic factor that contributefor this joint injuries and early identification along with biomechanical factors associated with knee joint injuries is important. The functional tests for knee valgus evaluation are important tools for assessing the dynamic alignment between body segments, but there is no kinesiological subsidies in the literature that compare knee, hip and trunk in most of the described functional tasks used in the clinical practice and their relationship with the hip and knee strengthin healthy subjects. This study aimsto compare the angle values by the trunk, hip and knee kinematics in five different functional tasks used to evaluate the dynamic valgus and correlate this with the muscle\'s torque of the hip and knee. A sample of 30 healthy volunteers (15 men and 15 women) aged 18 to 35, with no history of pain or dysfunction in the lower limbs, performed a isometric muscle strength tests for all theknee and hip groups muscles using an isokinetic dynamometer Biodex®. Between 3 and 7 days after the muscle strength testing trunk, hip and knee kinematic analysis was performedduring five different functional tasks for evaluating the dynamic knee valgus using the Vicon system (Centennial, CO, USA).The functional tests were: stair descent, single-leg step down, single leg squat, single leg landing, drop vertical jump. ANOVA repeated measures was used to verify the differencesin the tasks for knee, hip and trunk kinematics and Pearson\'s correlation was used to verify correlations between hip and knee muscle\'s torque and knee, hip and trunk kinematics. The drop vertical jump task showed the highest peak values of valgus (average: 20.1º p<=0,04), internal rotation of the knee (average: 9,7º p<=0,003), hip flexion (mean: 38,8º p<=0,001) and lower trunk rotation values (mean 0,07º p<=0,009). The single leg step down task showed greater trunk flexion values (mean: 10,2º p<=0,002) in relation to all functional tasks. It was observed a negative and weak correlation of thehip external rotators torque and ipsilateral trunk lean (R = - 0.36, p = 0.049) in stair descent task. There was no evidence of correlation between peak torque of the hip abductors, adductors, internal rotators, external rotators, flexors and extensors and flexors, extensors of the knee with knee, hip and trunk kinematics in the single leg squat, landing, drop vertical jump and single-leg step down. For choosing a functional task to evaluate the dynamic valgus is crucial to the clinicians understand the kinesiological variables of knee, hip and trunk. All assessed tasks are effective to evaluate the dynamic knee valgus, although the drop vertical jump task requires more adjustments in the knee and hip, and the single leg step down task has higher kinesiological changes in the trunk.In addition, knee and hip peak of torque had no influence on the performance of the tests in healthy individuals
30

Estudo comparativo da avaliação da rotação dos joelhos submetidos à reconstrução do ligamento cruzado anterior: feixe duplo x feixe simples / Evaluation of tibial rotational range during dynamic activities: double-bundle vs. single-bundle anterior cruciate ligament reconstruction

D\'Elia, Caio Oliveira 14 January 2015 (has links)
Em uma tentativa de melhor restabelecer a função normal do ligamento cruzado anterior (LCA), foi proposta a técnica de reconstrução do LCA com feixe duplo (FD). Entretanto, a superioridade desta técnica frente à técnica com feixe simples (FS) ainda não está claramente demonstrada no cenário clínico. O propósito do presente estudo foi avaliar e comparar a amplitude de rotação tibial, o máximo de rotação interna e externa, e a força de reação ao solo de joelhos submetidos à reconstrução anatômica com feixe duplo, a joelhos submetidos à reconstrução com feixe simples, durante a realização de tarefas dinâmicas. Para isso, um total de 75 (setenta e cinco) indivíduos foram avaliados (26 reconstruções feixe duplo, 22 reconstruções feixe simples, 27 indivíduos sem lesão do LCA que formaram um grupo controle). Utilizando um sistema de análise do movimento humano, constituído por 4 câmeras para a análise do movimento, os indivíduos foram avaliados em três tarefas de demandas distintas. Utilizou-se a técnica TSACCAST para o cálculo da rotação interna e externa da tíbia. A média da amplitude de rotação tibial, máximo de rotação interna e externa, foi avaliada para cada joelho em cada um dos três grupos. A avaliação clínica destes pacientes foi realizada utilizando-se questionários subjetivo e objetivo (IKDC), assim como artrometria manual. Estas avaliações revelaram que ambos os grupos operados eram semelhantes no que se refere ao resultado clínico pós-operatório. A avaliação da amplitude de rotação tibial, máximo de rotação interna e externa, demonstrou que o joelho operado era semelhante ao joelho não operado e aos joelhos do grupo controle. Também não se verificou diferença significativa nos valores de amplitude de rotação tibial, máximo de rotação interna e externa, quando se comparou o grupo FS ao grupo FD. Desta forma, concluímos que a reconstrução do LCA com a técnica de FS e com a técnica de FD são similares no que se refere ao restabelecimento do controle da rotação da tíbia / In an attempt to better restore the normal function of the two ACL bundles, the ACL reconstruction with two bundles has been proposed. However, the superiority of the double-bundle technique has not been clearly demonstrated in the clinical setting. The purpose of this study was to compare the tibial rotational range, maximal internal and external rotation and ground reaction force of anatomical double-bundle anterior cruciate ligament reconstructed knees with single-bundle anterior cruciate ligament reconstructed knees during three different demanding tasks. A total of 75 subjects, (26 with double-bundle anterior cruciate ligament reconstruction, 22 with single-bundle anterior cruciate ligament reconstruction, and 27 healthy control individuals) were evaluated in this study. Using a 4-camera motion analysis system, motion subjects were recorded performing during three different tasks. Using the CAST technique, the internal-external tibial rotation of both knees was calculated. The mean tibial rotational range, maximum internal and external rotation, for each knee, was evaluated for the 3 groups (double-bundle group, single-bundle group, and control group). Clinical assessment, including objective and subjective IKDC scores, and knee arthrometric measurement, revealed restoration of the reconstructed knee stability with no differences between the two anterior cruciate ligament reconstruction groups. The results demonstrated that both groups resulted in tibial rotation range values that were similar to those in the non-injured knees and those in the healthy controls. There were also no significant differences in tibial rotational range, maximal internal and external rotation and ground reaction force between the DB group and the SB group. Therefore, anatomical double-bundle and single-bundle reconstruction are able to restore normal tibial rotation

Page generated in 0.0857 seconds