• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 418
  • 5
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 435
  • 211
  • 109
  • 105
  • 104
  • 88
  • 84
  • 78
  • 71
  • 65
  • 61
  • 52
  • 51
  • 40
  • 38
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Desempenho de diferentes tipos de mantas sinteticas não tecidas na filtração da agua para irrigação localizada

Lima, Miller Marani 25 July 2018 (has links)
Orientador: Jose Euclides Stipp Paterniani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agricola / Made available in DSpace on 2018-07-25T11:56:25Z (GMT). No. of bitstreams: 1 Lima_MillerMarani_M.pdf: 1347770 bytes, checksum: 84dd71fa17f5329061804415f00d1db1 (MD5) Previous issue date: 1999 / Mestrado
42

Avaliação da filtração direta ascendente em pedregulho como pré-tratamento em sistemas de dupla filtração / Evaluation of direct upflow filtration in gravel as pretreatment in double filtration systems

Kuroda, Emília Kiyomi 26 April 2002 (has links)
Este trabalho consiste na avaliação do desempenho do sistema composto por filtração direta ascendente em pedregulho seguida de filtração rápida descendente. A investigação experimental foi realizada em instalação piloto, variando-se a taxa de filtração nos filtros ascendente (60 a 240 m3/m2.d) e descendente (100 a 240 m3/m2.d) com e sem execução de descargas de fundo intermediárias no ascendente. A água bruta foi proveniente de um manancial superficial com pH entre 6,5 a 7,5, valores de turbidez compreendidos entre 8,5 e 21 uT, cor verdadeira entre 19 e 50 unidades Hanzen e alcalinidade entre 6,7 e 10 mg CaCO3/L. Adicionalmente, verificou-se o comportamento da instalação, para uma condição simulada de ocorrência de pico de turbidez de 380 uT, com curta duração. Em função dos resultados obtidos foi possível realizar considerações com relação à ocorrência de desprendimento/carreamento contínuo de flocos no filtro ascendente e constatar as influências da execução de descargas de fundo intermediárias, com produção de efluentes de melhor qualidade e carreiras de filtração mais prolongadas. O filtro ascendente com taxa de filtração de 120 m3/m2.d, foi capaz de absorver o pico de turbidez de 380 uT, produzindo efluente pré-filtrado com valores de turbidez entre 0,3 e 5,7 uT, e o filtro descendente, com taxa de filtração de 180 m3/m2.d, produziu efluente final com valores consistentemente menores que 1 uT, e na maior parte do tempo menores que 0,1 uT. / This work consists of a performance evaluation of the system composed by direct upflow filtration in gravel followed by rapid downflow filtration in sand. The experimental investigation was accomplished in pilot installation, being varied the filtration rate in the upflow (60 to 240 m3/m2.d.) and downflow (100 to 240 m3/m2.d.) filters with and without execution of intermediate downflushes in the first one. The raw water was provided from a superficial source with pH between 6,5 to 7,5, turbidity values between 8,5 and 21 UT, visible colour between 19 and 50 uH and alkalinity between 6,7 and 10 mg CaC03/L. ln addition, the behavior of the installation was verified, for a simulate condition of turbidity peak occurrence of 380 uT, with short duration. From the obtained results it was possible to accomplish considerations concerning the detachment occurrence/continuous flowing of flakes in the upflow filter and to verify the influences of the execution of intermediate downflushes, with production of better quality effluents and longer filter runs. The upflow filter with filtration rate of 120 m3/m2.d. was able to attenuate the turbidity peak of 380 uT, producing prefiltered effluent with turbidity values between 0,3 and 5,7 uT, and the downflow filter, with filtration rate of 180 m3/m2.d. produced final effluent with consistently values lower than 1 uT and in most of time lower than 0,1 uT.
43

Avaliação da filtração direta ascendente em pedregulho como pré-tratamento em sistemas de dupla filtração / Evaluation of direct upflow filtration in gravel as pretreatment in double filtration systems

Emília Kiyomi Kuroda 26 April 2002 (has links)
Este trabalho consiste na avaliação do desempenho do sistema composto por filtração direta ascendente em pedregulho seguida de filtração rápida descendente. A investigação experimental foi realizada em instalação piloto, variando-se a taxa de filtração nos filtros ascendente (60 a 240 m3/m2.d) e descendente (100 a 240 m3/m2.d) com e sem execução de descargas de fundo intermediárias no ascendente. A água bruta foi proveniente de um manancial superficial com pH entre 6,5 a 7,5, valores de turbidez compreendidos entre 8,5 e 21 uT, cor verdadeira entre 19 e 50 unidades Hanzen e alcalinidade entre 6,7 e 10 mg CaCO3/L. Adicionalmente, verificou-se o comportamento da instalação, para uma condição simulada de ocorrência de pico de turbidez de 380 uT, com curta duração. Em função dos resultados obtidos foi possível realizar considerações com relação à ocorrência de desprendimento/carreamento contínuo de flocos no filtro ascendente e constatar as influências da execução de descargas de fundo intermediárias, com produção de efluentes de melhor qualidade e carreiras de filtração mais prolongadas. O filtro ascendente com taxa de filtração de 120 m3/m2.d, foi capaz de absorver o pico de turbidez de 380 uT, produzindo efluente pré-filtrado com valores de turbidez entre 0,3 e 5,7 uT, e o filtro descendente, com taxa de filtração de 180 m3/m2.d, produziu efluente final com valores consistentemente menores que 1 uT, e na maior parte do tempo menores que 0,1 uT. / This work consists of a performance evaluation of the system composed by direct upflow filtration in gravel followed by rapid downflow filtration in sand. The experimental investigation was accomplished in pilot installation, being varied the filtration rate in the upflow (60 to 240 m3/m2.d.) and downflow (100 to 240 m3/m2.d.) filters with and without execution of intermediate downflushes in the first one. The raw water was provided from a superficial source with pH between 6,5 to 7,5, turbidity values between 8,5 and 21 UT, visible colour between 19 and 50 uH and alkalinity between 6,7 and 10 mg CaC03/L. ln addition, the behavior of the installation was verified, for a simulate condition of turbidity peak occurrence of 380 uT, with short duration. From the obtained results it was possible to accomplish considerations concerning the detachment occurrence/continuous flowing of flakes in the upflow filter and to verify the influences of the execution of intermediate downflushes, with production of better quality effluents and longer filter runs. The upflow filter with filtration rate of 120 m3/m2.d. was able to attenuate the turbidity peak of 380 uT, producing prefiltered effluent with turbidity values between 0,3 and 5,7 uT, and the downflow filter, with filtration rate of 180 m3/m2.d. produced final effluent with consistently values lower than 1 uT and in most of time lower than 0,1 uT.
44

Parâmetros para Projeto e Operação de Filtros Orgânicos Utilizados no Tratamento de Águas Residuárias de Suinocultura / Parameters for designing and operation of organic filters used in treatment of swine wastewater

Magalhães, Marcos Alves de 26 August 2002 (has links)
Submitted by Marco Antônio de Ramos Chagas (mchagas@ufv.br) on 2017-02-10T09:54:12Z No. of bitstreams: 1 texto completo.pdf: 952247 bytes, checksum: cf297358ff052a8b67a6aba25bd97843 (MD5) / Made available in DSpace on 2017-02-10T09:54:12Z (GMT). No. of bitstreams: 1 texto completo.pdf: 952247 bytes, checksum: cf297358ff052a8b67a6aba25bd97843 (MD5) Previous issue date: 2002-08-26 / O trabalho foi dividido em duas etapas: montagem e operação de filtros orgânicos, utilizando-se bagaço de cana-de-açúcar e serragem de madeira como materiais filtrantes, e estudo do manejo desses materiais depois de descartados do filtro, pelo processo de compostagem, produzindo, ao final do período de maturação, adubo orgânico. Com base nos resultados obtidos, pôde-se concluir que todos os valores das concentrações relativas de sólidos nos efluentes dos filtros permaneceram aquém do valor de 50 mg.L -1 , citado por LEON e CAVALLINI (1999) como concentração admitida para um bom funcionamento do sistema de irrigação por gotejamento. O uso dos resíduos orgânicos mostrou-se eficiente para a filtragem das águas residuárias para fins de fertirrigação, notadamente em sistemas de irrigação localizada, uma vez que foram alcançadas taxas de remoção de 90 a 99 % de sólidos em suspensão (SS) e de 43 a 57 % de sólidos totais (ST) utilizando-se filtros de serragem de madeira e de 81 a 96 % de SS e de 50 a 56 % de ST com uso dos filtros de bagaço de cana-de-açúcar. A eficiência de filtragem aumentou com o passar do tempo, o que foi ocasionado pela obstrução gradativa dos poros, ocasionada pela retenção de sólidos das ARS nas colunas filtrantes. A altura da coluna filtrante entre 1,00m a 2,20m não alterou significativamente a eficiência dos filtros na remoção de SS. A eficiência média de remoção nos filtros foi superior a 80 % para SS e de 43 % para ST. Os materiais orgânicos utilizados como filtro, após terem sido retirados das colunas filtrantes, foram tratados pelo processo de compostagem. A utilização do dejeto de suínos na compostagem destes resíduos proporcionou a produção de adubos orgânicos de elevado valor fertilizante que, quando aplicados ao solo em taxas adequadas, torna-se excelente opção para a disposição harmônica desses resíduos no ambiente. Os parâmetros avaliados permitem concluir que o composto produzido apresentou características físicas, químicas e biológicas que atenderam a legislação federal, podendo ser classificado como composto orgânico, pois se enquadraram nas normas estabelecidas pelo Ministério da Agricultura. Pelos resultados obtidos na avaliação da composição química dos compostos maturados, as pilhas de bagaço de cana-de-açúcar + dejeto de suínos apresentaram teores mais elevados de N, Mg, Ca, Cu, Zn, Mn, Fe, Cd, Ni, Pb e Cr que o composto das pilhas de serragem de madeira + dejeto de suínos e inferiores quanto aos teores de P e K. A concentração total de metais pesados nos compostos produzidos pode ser considerada segura sob o ponto de vista de uso na adubação de culturas agrícolas. / The work was divided in two parts as following: the set up and operation of organic filters, using sugar cane-trash and saw dust as filtering material; and the study of handling these material after discarding the filter, by biological decomposition, producing organic fertilizer at the end of the maturation period. On the basis of these results it was concluded that all the values of the relative concentrations of solids in the filter effluents, remained below 50 mg.L -1 , reported by LEON and CAVALLINI (1999) as the accepted concentration for a good operation of the drip irrigation system. The use of the organic residues was shown efficient for the filtration of wastewater for fertirrigation uses. Particularly in systems of localized irrigation, once removal rates from 90 to 99 % of suspended solids (SS) and from 43 to 53% of total solids (TS) were reached using sawdust filters; and 81 to 96% of SS and 55 to 56 % of TS using cane-trash filters. The filtration efficiency increased with time, which was caused by the gradual obstruction of the pores, due to the wastewater solid retention in the filter columns. The filtering column height did not alter significantly filter efficiency in removing SS. The average filter removing efficiency was greater than 80% for SS and 43% for ST. After the organic materials used as filter have been removed from the filtering columns, they were treated by biological decomposition (composting). The use of swine manure in the decomposition of these residues provided the production of high value organic fertilizers. When these fertilizers are applied to the soil in adequate rates, they become excellent option for a harmonious disposal of these residues in the environment. The evaluated parameters permit the conclusion that the produced compost present physical, chemical and biological characteristics satisfying the federal legislation, and it can be classified as organic compost, as it meets the rules established by the Minister of Agriculture. The results obtained from the evaluation of the chemical composition of the matured compost showed that the cane-trash + swine residue heaps gave higher levels of N, Mg, Ca, Cu, Zn, Mn, Fe, Cd, Ni. Pb and Cr than the sawdust + swine residue heaps, and lower levels of F and K. The total concentration of heavy metals in the produced composts can be considered safe from the crop fertilization point of view. / Dissertação importada do Alexandria
45

Estudo da floculação, quebra e recrescimento de flocos com emprego de técnica de monitoramento contínuo em ensaios de bancada para as condições de tratamento de água por filtração direta

Adam Douglas Sebastião Pinto 05 August 2015 (has links)
Neste trabalho empregou-se um Equipamento de Monitoramento Contínuo da Floculação (EMCF), para melhor compreensão da formação, quebra e recrescimento de flocos, bem como o impacto na qualidade da água tratada por filtração direta descendente com pré-floculação em escala de bancada. Os flocos foram submetidos a gradientes de quebra variados, de 1400 s-1 a 101 s-1, condições passíveis de serem encontradas em filtros rápidos por gravidade, operados à taxa constante, e com durações da quebra de 5, 60 e 300 s. A água de estudo utilizada nos ensaios foi preparada em laboratório, com a adição de caulinita à água de um poço artesiano e apresentou valor de turbidez de 25 uT e pH de 6,50. O coagulante utilizado foi o sulfato de alumínio líquido isento de ferro (12,5 mg/L do produto comercial com teor de Al2O3 de 8,42%) em conjunto, ou não, com um polímero aniônico (0,05 mg/L). Foi possível observar que, os flocos, uma vez quebrados sobre distintos tempos e gradientes de velocidade, apresentaram diferentes potencialidades de recrescimento, sendo que, de maneira geral, quanto menores os valores dos gradientes de velocidade e durações da quebra, maior foi a capacidade dos flocos alcançarem tamanho semelhante ao observado antes do evento de quebra. Além disso, para a filtração direta com pré-floculação, observou-se que, para os maiores gradientes de velocidade e durações da quebra empregados no estudo, foram verificados os maiores valores de turbidez remanescente da água filtrada. Por outro lado, a aplicação conjunta do coagulante e polímero, para as mesmas condições de estudo, permitiu a obtenção dos menores valores de turbidez remanescente de água filtrada.
46

Optimização do processo de filtração de cerveja

Boaventura, Joana da Costa January 2009 (has links)
Estágio realizado na UNICER - Unicer bebidas, S. A. e orientado pela Eng.ª Maria Manuel Dantas / Tese de mestrado integrado. Engenharia Química. Faculdade de Engenharia. Universidade do Porto. 2009
47

Optimização da etapa de filtração-turvação total, regeneração do PVPP e teor em S02

Rocha, Cristiana Rosa Teixeira January 2008 (has links)
Estágio realizado na Unicer Cervejas, S. A. e orientado pelo Eng.ª Maria-Manuel Dantas / Tese de mestrado integrado. Engenharia Química. Faculdade de Engenharia. Universidade do Porto. 2008
48

Optimização da etapa de filtração de cerveja

Pinto, Ana Isabel Rodrigues Vaz January 2008 (has links)
Estágio realizado na UNICER- Leça do Balio e orientado pelo Eng.ª Maria Manuel Dantas / Tese de mestrado integrado. Engenharia Química. Faculdade de Engenharia. Universidade do Porto. 2008
49

Remoção de Cryptosporidium spp. no tratamento de águas por filtração em margem

Jangada, Victor Hugo January 2014 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Ambiental, Florianópolis, 2014. / Made available in DSpace on 2015-02-05T20:12:45Z (GMT). No. of bitstreams: 1 327994.pdf: 1803321 bytes, checksum: 56a909b73b9a9f302a055a42abe66ab2 (MD5) Previous issue date: 2014 / Com a crescente preocupação a respeito da poluição hídrica e as possíveis doenças que possam ser causadas através da contaminação com protozoários, surge a filtração em margem como uma das possíveis soluções para o problema, já que pode remover através de filtração os organismos que são resistentes a desinfecção química e algumas vezes podem acabar atingindo as redes de distribuição. Sendo assim, este trabalho objetivou avaliar a eficiência da filtração em margem em colunas de sedimento para remoção de Cryptosporidium spp. através do uso microesferas de poliestireno para simulação deste protozoário. Para consecução desta pesquisa, foi realizado um estudo contendo 5 colunas filtrantes a fim de simular os primeiros metros da filtração em margem, onde foram aplicadas as microesferas simuladoras do protozoário Cryptosporidium spp. Previamente a aplicação das microesferas, procurou-se identificar a quantidade de tempo necessária para que o sistema piloto fosse considerado aclimatado. O controle da qualidade da água produzida pela filtração em margem foi realizado através do monitoramento dos seguintes os parâmetros: carbono orgânico total, coliformes totais, condutividade, cor aparente, cor verdadeira, E. Coli, oxigênio dissolvido, pH, sólidos dissolvidos totais, temperatura e turbidez. A análise das microesferas de poliestireno foi realizada em microscópio de fluorescência. Com base nos resultados obtidos, considera-se aclimatado o sistema piloto após 45 dias de operação, pois nessa altura já é possível alcançar resultados suficientemente bons para se enquadrarem na Portaria nº 2914/2011. Foi também possível concluir que a filtração em margem mostrou-se efetiva na remoção de microesferas de poliestireno a partir de 3 m de leito filtrante. No que diz respeito a turbidez como indicador da presença de Cryptosporidium spp., considera-se que este não corresponde a um indicador confiável, pois houve a presença das microesferas de poliestireno até mesmo quando a turbidez alcançava valores menores que 0,5 uT, como recomenda a legislação brasileira.<br> / Abstract : With the increasing concern about water pollution and possible diseases that may be caused by contamination with protozoa, rises the bank filtration as a possible solution to the problem, since it can remove by filtration, organisms that are resistant to chemical disinfection and can sometimes end up reaching the distribution networks. Thus, this study aimed to evaluate the efficiency of bank filtration by sediment columns for the removal of Cryptosporidium spp. through the use of microspheres for simulation of this protozoan. To achieve this research, was performed a study containing 5 filter columns to simulate the first few meters of bank filtration, where the microspheres simulating the protozoan Cryptosporidium spp. was applied. Previously the application of microspheres, sought to identify the amount of time required for the pilot system to be considered acclimated. The control of the water quality produced by bank filtration was performed by monitoring the following parameters: total organic carbon, total coliform, conductivity, apparent color, true color, E. Coli, dissolved oxygen, pH, total solids dissolved, temperature and turbidity. The analysis of polystyrene microspheres was performed with a fluorescence microscope. Based on the results obtained, it is considered acclimated the pilot system after 45 days of operation, because then it is possible to achieve results good enough to fit the Brazilian legislation. It was also concluded that the bank filtration proved to be effective in the removal of polystyrene microspheres from 3 m filter bed. Regarding the turbidity as an indication of the presence of Cryptosporidium spp., it is considered that this does not correspond to a reliable indicator because there was the presence of polystyrene microspheres even when the turbidity reached values lower than 0,5 NTU, as recommended in Brazilian legislation.
50

Prevalência de alteração de taxa de filtração glomerular estimada em hipertensos atendidos na atenção primária do município de Vitória - ES

PASSIGATTI, C. P. 01 June 2011 (has links)
Made available in DSpace on 2016-08-30T10:50:10Z (GMT). No. of bitstreams: 1 tese_4887_.pdf: 332037 bytes, checksum: 116c418ebe2091fcc9aebf63a508a23c (MD5) Previous issue date: 2011-06-01 / hipertensão é a principal causa de doença renal crônica no Brasil e como monitorização da função renal, utiliza-se a estimativa da filtração glomerular (FG), pois a detecção precoce da doença renal torna-se a medida mais importante para retardar a progressão da doença, principalmente entre os considerados grupos de risco como hipertensos O estudo objetiva investigar a função renal de hipertensos atendidos na atenção primária do município de Vitória ES e três diferentes equações utilizadas para estimar a taxa de filtração glomerular. Trata-se de estudo transversal de dados secundários, observacional, com 754 hipertensos atendidos nas unidades de saúde, em 2009. Para análise estatística, utilizou-se o teste qui-quadrado e a concordância entre as equações foi analisada mediante teste Kappa. Houve predominância do sexo feminino (67,2%), excesso de peso (73,7%) e pressão arterial não controlada (56,9%). A média de idade foi de 58,18 anos (±13,52) e da creatinina sérica (CrS) 0,81mg/dl (±0,28). A prevalência da FG reduzida foi de 19% quando de 30 a 59ml/min e 1,6% quando de 29 a 15ml/min e apresentou-se 15 vezes maior em idosos, 4,93 vezes maior naqueles com CrS elevada, 2,19 vezes nos hipertensos com baixo peso e 1,6 vez mais prevalente em homem. Houve razoável, moderada e forte concordância entre as equações de Cockcroft-Gault e MDRD, Cockcroft-Gault corrigida e MDRD e Cockcroft- Gault e Cockcroft-Gault corrigida, respectivamente, apesar de utilizarem parâmetros distintos. Esses resultados mostram a importância de monitorar a função renal com vistas à intervenção precoce e retardamento da perda de função renal em hipertensos.

Page generated in 0.0666 seconds